Repairs And Maintenance Of Perimeter And Security Light Fittings At Cvrde Avadi

Tender Notice

25687083
Repairs And Maintenance Of Perimeter And Security Light Fittings At Cvrde Avadi
Indian
Tamil Nadu
10-10-2020
28-10-2020
31-10-2020

Tender Details

Repairs And Maintenance Of Perimeter And Security Light Fittings At Cvrde Avadi

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.00 /-
Tender Value
INR 9.50 Lakhs /-

BOQ Items

Nature of Work : REPAIRS AND MAINTENANCE OF PERIMETER AND SECURITY LIGHT FITTINGS AT CVRDE AVADI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down carefully existing unserviceable LED street light fittings of any capacity & size & any make from poles and refixing the same on existing location after making the LED fitting serviceable by replacement of defective drivers/surge protection device as required with new one complete all as specified and directed Note:- (i) Spare parts required for replacement shall be measured and paid separately under relevent items 2,3 of BOQ. (ii) The cost of Replacement of minor Parts i.e. nuts/bolts,connectors etc are deemed to be included in this item. 40 Each Job
2 2 Supply only constant current LED driver for energy saving & environment area light fitting upto 75watts security light with active power factor correction (APFC) electronic driver with operating voltage between 100-270V AC of suitable for existing street light of make Surya/C&S/ Crompton/Havells/Bajaj/Philips/Wipro complete all as specified and directed. 15 Each
3 3 Supply only constant current LED driver for energy saving & environment area light fitting upto 100watts security light with active power factor correction (APFC) electronic driver with operating voltage between 100-270V AC of suitable for existing steel lights of make Surya/C&S/ Crompton/Havells/Bajaj/Philips/Wipro complete all as specified and directed. 10 Each
4 4 Supply only Surge Protection Device (SPD) of capacity 10 KV for LED energy saving & environment area light of 45-90 watts security light with maximum operating voltage 320V AC, 50 Hz & maximum peak current 10 KA of suitable for existing streel lights of make Surya/C&S/ Crompton/Havells/Bajaj/Philips/Wipro complete all as specified and directed. 15 Each
5 5 S&F in replacement of LED street light fixture not less than 72/70Watt LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit with suitable size GI bracket/clamps etc incl taking taking down HPSVMV/MH fittings complete all as specified and directed. Make: Havells Cat No ENDURACITYLINERNEOSL70WLED757PASYBOTG/CG Cat No LSTP-72-CDL-M/Wipro Cat part No LR02-781-XXX-57-G2 30 Each
6 6 S&F garden light new generation type , energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LED as light source.Havells Cat Part NO BAMBOOBL8WLED857SSYMTOPC (0.5M) and CG cat Part No LBLSR-10-CDL 6 Each
7 7 S&F Post top LED light fittings not less than 25Watt LED with polycarbonate housing with opal/clear diffuser, IP-66 degree of protection, luminarie efficiency 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, including taking dowm CFL fittings any complete all as specified and directed Make :- Havells Cat No UBYPT25WLED830SSYMTOPC or equivelant CG/Bajaj 10 Each
8 8 M&L for taking down high mast latern unit and S&F in repair LED flood light fitting energy efficient not less than 160Watt LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit and incl provn suitable clamps/bolts, nuts and conneting flexible copper wire incl taking down u/s conventional flood light fittings complete all as specified and directed . Make :- Havells JETAIRISFLS160WLED 757PWBLTG/ Bajaj BARFEG160W LED/CG Cat No LFLN-180-CDL/60-M/ 10 Each
9 9 S&F in repair LED flood light fitting energy efficient not less than not less than 90Watt LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit and incl provn suitable clamps/bolts, nuts and conneting flexible copper wire incl taking down u/s conventional flood light fittings complete all as specified and directed . Make :- Havells JETAIRISFLS160WLED757PWBLTG/ BRLEP 90W LED V3/CG Cat No LFLN-180-CDL/60-M/CG Cat No LFLN-120-CDL/60-M 6 Each
10 10 Supply and Laying XLPE cable of size10 sqmm 2 core 1100 Volt grade heavy duty aluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size lugs/glandsas required complete all as specified and as directed. 200 RM
11 11 Supply and Laying XLPE cable of size 16 sqmm 4 core 1100 Volt grade heavy duty aluminium conductor laid in trenches / fixed to wall / pole / laid in floorincluding necessary connection and suitable size lugs/glandsas required complete all as specified and as directed. 150 RM
12 12 Supply and laying GI pipe “light Grade” in trenches/under floors or roads or along the pole for protection of cables of 40 mm bore including taking down u/s GI pipe any type any size complete all as specified and as directed. complete all as directed. 24 RM
13 13 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/dense soil 92 Cum
14 14 Retruning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms of soil complete all as specified and directed. 49 Cum
15 15 Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 2.5 Mtr above the starting point all as specified and directed. 43 Cum
16 16 Supply and spread sand for sand cushioning of cables in trenches all as specified in MES Schedule Part-I and all as directed. Note: Punned thickness only will be measured and paid. 30 Cum
17 17 Supply and laying old size brick, size 230x115x75mm burnt clay building brick sub class (B) for protecting LT U/G cable complete. 3050 Each
18 18 Supply and fix in replacement of analog time switch 24hours range suitable for autamatic ON/OFF control of street light 230V,50Hz complete all as specifed and directed. 5 Each
19 19 Taking down the lanteren carrige assembly along with lanterns after replacement of worn out pully at top section of high mast ,welding putting the fell down wire rope in pully groves in proper alignment for satisfactory operation of winch system by arranging hydraulic crane from civil market having boom suitable for working at 16 mtr height all as directed and carrying out work all as directed. (Note:-Cost of hiring of hydraulic crane suitable for working at above 16 mtr height and T&P used for repair of high mast is deemed to be includadin unit rate and spare shall be measure and paid seperatly) 2 Each Job
20 20 Rewinding of motor 2 HP ,3 phase ,415 volts ,1425 RPM with copper wire of existing size and varnishing complete and testing all as directed. 1 Each
21 21 Supply and fix in replacement of bearing SKF 4026 all as directed. 1 Each
22 22 Taking out old unserviceable under ground PVC/XLPE LT cable of any size from trenches/ wall/roof/road/pipe/pole including segregation of serviceable bricks for re-use complete all as specified and as directed. 450 RM
23 23 Relaying of old serviceable under ground PVC/XLPELT cable any grade and any size in trenches/fixed to wall/pole/roof/laid in floor including necessary connections and thimbling complete all as specified and as directed. (Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).\n 100 RM
24 24 Re-laying only old bricks, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed. 1 1300 Each
25 25 Supply and fix in replacement of junction box made of inpact resistance plastic & heat resistant materials of size not less than 230x170x105mm, IP 66 protection, single left hinged door including provision of suitable terminal connector 16A capacity with MCB SP 6A and fixing to the surface/light pole with suitable sizes of clamps, nuts and bolts complete all as specifed and directed. 15 Each
26 26 Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size any core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junctionbox/LT panel/O/H line etc all as directed. Note:- (I) the cost of required earth work ie excavation,returning filling,relaying of sand/bricks and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid seperatly. 15 Each
27 27 Supply and fixing in replacement of MCB , SP ,240Volt, 6 Amp 10KA all as specified and as directed. 18 Each
28 28 S&F in replacement of Power Contractor 2Pole 32A AC-3 230V Volts,50Hz coil voltage rating 240 volts including taking down old UNSV power contractor complete all as specified and directed. 3 Each
29 29 S&F in replacement of Power Contractor 3Pole 25A AC-3 415V Volts,50Hz coil voltage rating 415 volts including taking down unserviceable power contractor complete all as specified and directed. 4 Each
30 30 Supply and fix in replacement of PVC insulated, PVC sheathed, 3 core multi stranded copper conductor of size 1.5 Sqmm for connecting to streetlight fitting passing through conduit fixed including taking down existing cable complete all as specified and as directed. Note:- Conduit and coduit accessories shall be measured paid separately under respective item of this schedule 200 RM
31 31 Supply and fix in repalcement of medium duty non matalic PVC conduit of 20 mm bore including all fitting such as bends, elbow, coupler lock nut etc, fixed along pole with clamp for streetlight including taking down old PVC conduct of any type complet all as specified and directed. 200 RM
32 32 M&L for cleaning the steel tubular poles of any height and throughly with necessary cleaning agent including scrappin up of old corroded paint dirt/dust/ rust carefully and applying two coat of synthetic aluminium paint over one coat of red oxide metal primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including marking of pole numbers all as specified and directed. 85 Job
33 33 M&L for cleaning the PSCC poles of any height and throughly with necessary cleaning agent including scrappin up of old paint dirt/dust carefully and applying two coat of cement based paint over one coat of primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of cement based paint including marking of pole numbers all as specified and directed. 80 Job
34 34 Taking down Old UNSV PCC and S&F new Supply, install and testing of steel tubular swaged pole 4 Mtr with sitable size MS base plate and entry holes at the bottom and foundation bolt as per require size, single arm mounting bracket (single swan neck) with support pipe/plate with bolts and check nuts for fixing the street light fitting and internal bus bar chamber with 4 way connector, flush type hexagonal screws for connecting the in/out cables and required cable from connector to light fitting, open raft shallow footing of required size to match with the base plate and standard drawing all as per design of poles approved by Engr in charge.\nNote: The Rate quoted shall includes for Earth work excavation, Concrete foundation and foundation bolts. 5 Each Job
35 35 Supply and fixing energy in repair efficient LED security/street light fitting of not less than 30 Watt seasonal RTC control with dimmable type, including No. of LED bulbs as per manufacturers instructions for lighting of not less than 30 watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection for cable connection complete all as directed by Engineer-in-Charge. Make- ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC of Havells/ BRP050 LED 036 CW HP SLA FG S1 PSU GR of Philips/BCLST 30W LED I of Bajaj 5 Each