Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #25680758

Replacement Of Street Lights And Perimeter Lights At Nasa Cera And Connected Items Along Boundary Wall At Ina Ezhimala Under Ge Maint Ezhimala As Per Boq And Tender Documents

Issued by Statutory Bodies & Commissions/Committees · EZHIMALA, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Oct 2020
0 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
EZHIMALA → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Replacement Of Street Lights And Perimeter Lights At Nasa Cera And Connected Items Along Boundary Wall At Ina Ezhimala Under Ge Maint Ezhimala As Per Boq And Tender Documents

BOQ

Name of Work: REPLACEMENT OF STREET LIGHTS AND PERIMETER LIGHTS AT NASA,CERA AND CONNECTED ITEMS ALONG BOUNDARY WALL AT INA EZHIMALA UNDER GE(MAINT) EZHIMALA
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Taking down the unserviceable LT UG cable of size of 6 Sqmm to 25 sqmm including removing electrical connection and keeping side serviceable cable include removing cable protection cover etc all as specified and as directed by Engineer in charge.\n1900RM
22Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard and dense soil all as specified and as directed.Note: The excavation has to be done manually only189Cum
33Returning and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil61Cum
44Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point.128Cum
55Supply and spreading river sand or riddled earth for cushioning and covering of the UG cable in trenches all as specified and directed by Engineer in charge.75.6Cum
66Supply and lay PCC un reinforced cable cover of size 250 mmx150mmx40mm , class LV type I flat for cable protection complete all as specified and directed.6500Each
77Relaying cable XLPE insulated heavy duty galvanised steel strip armoured LT 1100 volt grade with aluminium conductors multistranded confirming to IS laid in trenches/pipes/wall size up to 25 sqmm 4 core.\n300RM
88Relaying of PCC un reinforced LTcable cover of size 250 mmx150mmx40mm item obtained from ser no 1 complete all as specified and directed by Engr in charge.3100Each
99Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size 6 sqmm 2core complete all as specified and directed by Engineer in charge. \nMake Havells, RPG, Polycab.400RM
1010All as per item no. 9 above but size of 10 sqmm 2core complete all as specified and directed by Engineer in charge.\nMake Havells, RPG, Polycab.500RM
1111All as per item no. 9 above but size of 16 sqmm 4.0 core complete all as specified and directed by Engineer in charge. \nMake Havells, RPG, Polycab.500RM
1212All as per item no. 9 above but size of 25 sqmm 4.0 core complete all as specified and directed by Engineer in charge.\nMake Havells, RPG, Polycab.500RM
1313All as per item no. 9 above but XLPE armoured cable with copper conductor of size 4 sqmm 3 core complete all as specified and directed by Engineer in charge. \nMake Havells, RPG, Polycab.100RM
1414All as per item no. 9 above but XLPE armoured cable with copper conductor of size 2.5 sqmm 3 core complete all as specified and directed by Engineer in charge.\nMake Havells, RPG, Polycab.200RM
1515Supply and fix integral Aviation LED light fitting comprising of aluminium housing with polycarbonate enclosure.\nMake:- Crompton,Philips,Wipro.2Each
1616Material and labour for mass filling in foundation/coping/wall with PCC 1:3:6 using 20 mm graded aggregate type C1 as site requirement complete all as specified and directed by Engr in charge2Cum
1717M & L for dismantling/removal of existing pole of Post top lantern of any type from it's position/foundation after necessary exavation and earth work and refixing on site all as specified and directed by Engineer in charge.20Each job
1818Cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.5 Mtr and depth 0.7 Mtr all as directed and making good the road/hard using pre mix bituminous as required at site to match with the existing surface all as specified. \nNOTE: Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by Engr-in-charge.30RM
1919Supply and fix High density poly Ethylene pipes(HDPE) of pressure rating 6kgf/ cm2 laid in trenches of size 80mm dia.40RM
2020Supply and fix in replacement of Copper cable flexible 2.5 Sqmm 3 core 230 Volts complete all as specified and as directed by Engr-in-charge.\nMake : Polycab/Havells/Finolex.1600RM
2121Supply and fix in replacement of digital time switch day programme single phasecomplete all as specified and as directed by Engr in charge. \nMake L&T/ Philips/C&S.30Each
2222Supply and fix in replacement of contactor four pole 415 volt 63 Amp complete all as specified and directed by Engr in charge. Make L&T/Schneider/Seimens.20Each
2323Supply and fix in replacement of decorative post top for 360 degree indirect light with IP 65 protection ,resistant to impact and corrosion, out put lumens per watt is greater than 100 lumens all as specified and as diected by Engr in charge.\nMake Crompton/ Wipro/Philips.40Each
2424Supply and fix in replacement bollard light fitting twister type robust design LED light 10W ,IP 65 proctection all as specified and as directed by Engr in charge. \nMake Crompton,PHILIPS,Wipro50Each
2525Supply and fix in replacement of old unserviceable street light fitting with LED street light fittings Luminaire 60 watts ,240V 50Hz pressure die cast aluminiumhousing with toughened and heat resistant glass ,IP 66 protection, out put lumens per watt is greater than 100 lumens all as specified and as diected by Engr in charge. \nMake: crompton//Philips/Wipro.40Each
2626All as per item No - 25 above but of capacity 90 watt,out put lumens per watt is greater than 100 lumens all as specified and as diected by Engr in charge. \nMake - CG/Wipro/Philips.15Each
2727All as per item No - 25 above but of capacity 45 watt,out put lumens per watt is greater than 100 lumens all as specified and as diected by Engr in charge. \nMake - CG/Wipro/Philips.30Each
2828S&F in replacement die cat aluminium IP 66 30W LED flood light luminaire out put lumens per watt is greater than 100 lumens all as specified and as diected by Engr in charge.complete all as specified and directed by Engr in charge.\nMake:- Crompton/Philips/Wipro.20Each
2929Supply and fixing in replacement of LED flood light luminare 50 W with high pressure die cast housing,out put lumens per watt is greater than 100 lumens all as specified and as diected by Engr in charge. \nMake:- Crompton/Philips/Wipro.20Each
3030S&F in replacement die cat aluminium IP 66 120W LED flood light luminaire,out put lumens per watt is greater than 100 lumens all as specified and as diected by Engr in charge. \nMake:- Crompton/Bajaj/Havells .10Each
3131S&F in replacement die cat aluminium IP 66 150W LED flood light luminaire,out put lumens per watt is greater than 100 lumens all as specified and as diected by Engr in charge. \nMake:- Crompton/Philips/Wipro.10Each
3232Supply and fix in replacement of bracket made out of GI pipe medium grade, 50 mm dia, 90 cm long for fixing street light with and including clamps, nuts, bolts, washer complete accessories and applying two coats of oil painting over one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.15Each Job
3333Supply and fix in replacement weather proof street light junction boxes made out of Thermo plastic consisting of 4 nos of connectors of capacity 40 amp 415v and 1no of SP MCB rating 6 AMP 240 V with proper closing arrangement, elmax connector for neutral link including pole mounting clamp with nut bolts. The size of the box shall be of size 205mmx255mm112 mm.The box should have two cable entry. \nMake:- Sintex/ schneider/L&T.40Each
3434M&L universal LED driver 40 Watt to 60 watt all as specified and as directed by the Engr in charge.\nMake:- Havells/Wipro/Crompton40Each
3535S& F MCB SP 6A to 32 Amp all as specified and as directed by the Engr in charge.\nMake:- L&T,Indoasian,Standard.15Each
3636S&F MCB DP 'C' curve up to 32 Amps all as specified and as directed by the Engr in charge.\nMake:- L&T,Indoasian,Standard.10Each
3737All as per item No 36 above but TPN 63Amp all as specified and as directed by the Engr in charge.\nMake:- L&T,Indoasian,Standard.15Each

AI Tender Summary

OUR REF NO 25680758
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 28-10-2020
Authority
Authority Name Military Engineer Services
Work Description Replacement Of Street Lights And Perimeter Lights At Nasa Cera And Connected Items Along Boundary Wall At Ina Ezhimala Under Ge Maint Ezhimala As Per Boq And Tender Documents
Basic Detail
Tender No GE MAINT EZHIMALA 8344
Bidding Type Tender
Location
City EZHIMALA
State Kerala
Key Dates
Publish Date 10 Oct 2020
Submission Date 28 Oct 2020
Open Date 30 Oct 2020
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 60000
Exemption Not Available
Document List
BOQ_429402.xls
7B8B769C-F6D9-4A87-8161-417EAFE99CEF.html
Tenderdocument8344.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 01, 1900
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 30, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_429402.xls

html

7B8B769C-F6D9-4A87-8161-417EAFE99CEF.html

pdf

Tenderdocument8344.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender