Military Engineer Services-MES has published Repairs / Replacement Of Summer Colling Appliance At Parundu Under Ge Tirunelveli. Submission Date for this Tender is 28-10-2020. Air Conditioner Tenders in Ramnad Tamil Nadu. Bidders can get complete Tender details and download the document.
Name of Work: REPAIRS /REPLACEMENT OF SUMMER COOLING APPLIANCES AT PARUNDU UNDER GE TIRUNELVELI 8123 /E8 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | SCHEDULE 'A' PART -I(E/M PORTION) | |||
2 | 2 | Providing comprehensive annual maintenance periodical/preventive maintenance including annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as listed in particular specification as per manufacturer specification at INS PARUNDU RAMNAD by providing one AC/Refrigeration mechanic each for one general shift all as specifide and directed and including replacement of minor components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:-\n(a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil.\n(b) Cleaning of air filters, indoor unit grills & filters through air blower.\n(c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period.\n(d) Check and replace the refrigerent pipe once in a contract period or as and when required.\n(e) Check and repair the minor electrical fault in incoming supply.\n(f) Check and replace the water PVC pipe.\n(g) Replacement of faulty spares/components\n(h) Carry out the monthly, quarterly and annual maintenance of all cooling applicances of any make & capacity with job card \nNote:- General Shift ( 900 Hrs to 1700 Hrs)- One Ref Mech. | BI01010001010000000000000515BI0100001114 | 11 | Per Job |
3 | 3 | Supply only the following new items for 1.5 / 2.00 Ton Capacity Split type AC including testing and commissioning etc complete all as directed. | BI01010001010000000000000515BI0100001115 | ||
4 | 4 | Capacitor 60 MFD. | 35 | Each | |
5 | 5 | Air filters. | BI01010001010000000000000515BI0100001117 | 15 | SET Of 02 |
6 | 6 | Condenser fan motor 1.5 HP with blade set . | 25 | Each | |
7 | 7 | Blower fan motor 1.6 HP with blade set. Make: | 25 | Each | |
8 | 8 | Blower with circular leaf. | 25 | Each | |
9 | 9 | Copper condenser coil unit (for A/C) | 12 | Each | |
10 | 10 | Copper cooling coil unit (for A/C) | 12 | Each | |
11 | 11 | Indoor motor capacitor 2.5 MFD. Make: | 35 | Each | |
12 | 12 | Stainer tube (copper) | 15 | Each | |
13 | 13 | Capillary tube (copper) | 15 | Each Set | |
14 | 14 | Non return valve (For gas top up charging) | 15 | Each | |
15 | 15 | Remote control suitable for Non inverter model Split AC. Make : LG\n | 12 | Each | |
16 | 16 | Remote control suitable for Non inverter model Split AC. Make : Bluestar\n | 6 | Each | |
17 | 17 | Remote control suitable for Non inverter model Split AC. Make : Daiken\n | 4 | Each | |
18 | 18 | Remote control suitable for Non inverter model Split AC. Make : Universal\n | 4 | Each | |
19 | 19 | Remote control suitable for inverter model Split AC. Make : Bluestar\n | 4 | Each | |
20 | 20 | Remote control suitable for inverter model Split AC. Make : Daiken\n | 4 | Each | |
21 | 21 | PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : LG | 12 | Each | |
22 | 22 | PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : Bluestar | 5 | Each | |
23 | 23 | PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : Daiken | 4 | Each | |
24 | 24 | PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make : LG | 3 | Each Set | |
25 | 25 | PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make : LG | 3 | Each Set | |
26 | 26 | PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make : Daiken | 3 | Each Set | |
27 | 27 | PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make : Daiken | 4 | Each Set | |
28 | 28 | Copper pipe of size 1/2" for suction line with foam insulation | 40 | Running Metre | |
29 | 29 | Copper pipe of size 1/4" for discharge line with foam insulation | 40 | Running Metre | |
30 | 30 | Swing Motor for indoor unit\n | 12 | Each | |
31 | 31 | Outdoor unit stand | 11 | Each Set | |
32 | 32 | Condenser fan motor blade | 25 | Each Set | |
33 | 33 | Indoor Motor blower | 25 | Each | |
34 | 34 | Supply and fix PVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed. | 35 | Running Metre | |
35 | 35 | Metal plug top for AC | 20 | Running Metre | |
36 | 36 | Supply only the new following items for for 3.00 Ton Capacity Floor standing /Voltas make Tower AC including testing and commissioning etc complete all as directed. | |||
37 | 37 | Air filters. | 1 | SET OF 02 | |
38 | 38 | Condenser fan motor with blade set . | 1 | Each | |
39 | 39 | Blower fan motor with blade set. | 1 | Each | |
40 | 40 | Blower with circular leaf. | 1 | Each | |
41 | 41 | Condenser coil unit (for A/C) | 1 | Each | |
42 | 42 | Cooling coil unit (for A/C) | 1 | Each | |
43 | 43 | Indoor motor capacitor 2.5 MFD. | 1 | Each | |
44 | 44 | Stainer tube (copper) | 1 | Each | |
45 | 45 | Capillary tube (copper) | 1 | Each | |
46 | 46 | Non return valve (For gas top up charging) | 1 | Each | |
47 | 47 | Remote control suitable for Non inverter Tower AC. \n | 1 | Each | |
48 | 48 | PCB board suitable for outdoor unit. | 1 | Each | |
49 | 49 | PCB board suitable for indoor unit. | 1 | Each | |
50 | 50 | Copper pipe of size 5/8" for suction line with foam insulation | 8 | Running Metre | |
51 | 51 | Copper pipe of size 3/8" for discharge line with foam insulation | 8 | Running Metre | |
52 | 52 | Swing Motor for indoor unit\n | 1 | Each | |
53 | 53 | Outdoor unit stand | 1 | Each Set | |
54 | 54 | Condenser fan motor blade | 1 | Each Set | |
55 | 55 | Indoor Motor blower | 1 | Each | |
56 | 56 | Supply and fix PVC insulated unsheathed cables of size 4 sqmm 5 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed. | 10 | Running Metre | |
57 | 57 | Three phase metal plug top | 1 | Running Metre | |
58 | 58 | Supply only the new following items for water cooler 40/80 Litres capacity including testing and commissioning etc complete all as directed. | |||
59 | 59 | Relay unit | 3 | Each | |
60 | 60 | PVC float valves , high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15 mm. | 3 | Each | |
61 | 61 | Thermostat asssembly | 3 | Each | |
62 | 62 | Water tap suitable for water cooler.\n | 3 | Each | |
63 | 63 | Starting Capacitor 80-100 MFD | 3 | Each | |
64 | 64 | Running capcitor 36 MFD | 3 | Each | |
65 | 65 | Condenser fan motor 1.6HP with blade set | 3 | Each | |
66 | 66 | Over load protector (OLP) | 3 | Each | |
67 | 67 | Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :- | |||
68 | 68 | Split type AC 1.5 Ton capacity. Make: Bluestar or Voltas /LG/Samsung/Panasonic\n | 13 | Each | |
69 | 69 | Split type AC 2.0 Ton capacity. Make: Bluestar or Voltas /LG/Samsung/Panasonic\n | 4 | Each | |
70 | 70 | Water cooler 40/80 Litres capacity . Make: Samsung or Voltas /LG/Bluestar\n | 3 | Each | |
71 | 71 | Floor standing/Tower AC 3 Ton Capacity. Make : Voltas or LG/Bluestar/Samsung | 1 | Each | |
72 | 72 | Repair to stabilizer of capacity 4 or 5 KVA capacity by removing the old / burnt transformer and replaced with new transformer complete all as directed. | 15 | Each | |
73 | 73 | Repair to stabilizer by removing the old / burnt relay board suitable for Voltage stabilizer of capacity 4 KVA / 5 KVA capacity | 15 | Each | |
74 | 74 | M & L Painting complete with super enamel paint of approved colour for water cooler all as specified and directed. | 10 | Each Job | |
75 | 75 | Supply and fix condensed water PVC flexible pipe of standard quality of suitable size fixing with suitable clamps on wall for split type AC of capacity of 1.5/2.0 Ton complete all as specified and as directed. | 120 | Running Metre | |
76 | 76 | Supply only R22 /R32 /R410 Gas complete all as specified and directed. | 80 | KG | |
77 | 77 | Supply only R134a Gas complete all as specified and directed. | 10 | KG | |
78 | 78 | Dismantling and dis connecting carefully the existing split AC 1.5/2.0 Ton capacity after disconnecting the copper pipe and electrical connection, Cleaning the refrigeration system with CO2 and fixing in a new position including, brazing, testing and commissioning complete all as directed for the following cooling appliances :-\nNOTE : The wt of refrigerent used for filling/top up shall be measured and paid under respective item. | 10 | Each Job | |
79 | 79 | Supply only 2 nos of 1/2" x 3/8" Foam Heat Insulated Pipe Black for Air Conditioner | 30 | Each Set | |
80 | 80 | Materia and lobour for making good of surface with sealing the cavity /hole drilled to facilitate tubing, using white cement/POP and cleaning the surface to match with existing surface complete. | 30 | Each Job | |
81 | Total in Figures |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail