}

Repairs / Replacement Of Summer Colling Appliance At Parundu Under Ge Tirunelveli, Ramnad-Tamil Nadu

Military Engineer Services-MES has published Repairs / Replacement Of Summer Colling Appliance At Parundu Under Ge Tirunelveli. Submission Date for this Tender is 28-10-2020. Air Conditioner Tenders in Ramnad Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

25679756
Repairs / Replacement Of Summer Colling Appliance At Parundu Under Ge Tirunelveli
Open Tender
Indian
Tamil Nadu
Ramnad
28-10-2020

Tender Details

Repairs / Replacement Of Summer Colling Appliance At Parundu Under Ge Tirunelveli

Key Value

Document Fees
INR 500 /-
EMD
INR 24000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIRS /REPLACEMENT OF SUMMER COOLING APPLIANCES AT PARUNDU UNDER GE TIRUNELVELI 8123 /E8
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SCHEDULE 'A' PART -I(E/M PORTION)
2 2 Providing comprehensive annual maintenance periodical/preventive maintenance including annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as listed in particular specification as per manufacturer specification at INS PARUNDU RAMNAD by providing one AC/Refrigeration mechanic each for one general shift all as specifide and directed and including replacement of minor components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:-\n(a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil.\n(b) Cleaning of air filters, indoor unit grills & filters through air blower.\n(c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period.\n(d) Check and replace the refrigerent pipe once in a contract period or as and when required.\n(e) Check and repair the minor electrical fault in incoming supply.\n(f) Check and replace the water PVC pipe.\n(g) Replacement of faulty spares/components\n(h) Carry out the monthly, quarterly and annual maintenance of all cooling applicances of any make & capacity with job card \nNote:- General Shift ( 900 Hrs to 1700 Hrs)- One Ref Mech. BI01010001010000000000000515BI0100001114 11 Per Job
3 3 Supply only the following new items for 1.5 / 2.00 Ton Capacity Split type AC including testing and commissioning etc complete all as directed. BI01010001010000000000000515BI0100001115
4 4 Capacitor 60 MFD. 35 Each
5 5 Air filters. BI01010001010000000000000515BI0100001117 15 SET Of 02
6 6 Condenser fan motor 1.5 HP with blade set . 25 Each
7 7 Blower fan motor 1.6 HP with blade set. Make: 25 Each
8 8 Blower with circular leaf. 25 Each
9 9 Copper condenser coil unit (for A/C) 12 Each
10 10 Copper cooling coil unit (for A/C) 12 Each
11 11 Indoor motor capacitor 2.5 MFD. Make: 35 Each
12 12 Stainer tube (copper) 15 Each
13 13 Capillary tube (copper) 15 Each Set
14 14 Non return valve (For gas top up charging) 15 Each
15 15 Remote control suitable for Non inverter model Split AC. Make : LG\n 12 Each
16 16 Remote control suitable for Non inverter model Split AC. Make : Bluestar\n 6 Each
17 17 Remote control suitable for Non inverter model Split AC. Make : Daiken\n 4 Each
18 18 Remote control suitable for Non inverter model Split AC. Make : Universal\n 4 Each
19 19 Remote control suitable for inverter model Split AC. Make : Bluestar\n 4 Each
20 20 Remote control suitable for inverter model Split AC. Make : Daiken\n 4 Each
21 21 PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : LG 12 Each
22 22 PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : Bluestar 5 Each
23 23 PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : Daiken 4 Each
24 24 PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make : LG 3 Each Set
25 25 PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make : LG 3 Each Set
26 26 PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make : Daiken 3 Each Set
27 27 PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make : Daiken 4 Each Set
28 28 Copper pipe of size 1/2" for suction line with foam insulation 40 Running Metre
29 29 Copper pipe of size 1/4" for discharge line with foam insulation 40 Running Metre
30 30 Swing Motor for indoor unit\n 12 Each
31 31 Outdoor unit stand 11 Each Set
32 32 Condenser fan motor blade 25 Each Set
33 33 Indoor Motor blower 25 Each
34 34 Supply and fix PVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed. 35 Running Metre
35 35 Metal plug top for AC 20 Running Metre
36 36 Supply only the new following items for for 3.00 Ton Capacity Floor standing /Voltas make Tower AC including testing and commissioning etc complete all as directed.
37 37 Air filters. 1 SET OF 02
38 38 Condenser fan motor with blade set . 1 Each
39 39 Blower fan motor with blade set. 1 Each
40 40 Blower with circular leaf. 1 Each
41 41 Condenser coil unit (for A/C) 1 Each
42 42 Cooling coil unit (for A/C) 1 Each
43 43 Indoor motor capacitor 2.5 MFD. 1 Each
44 44 Stainer tube (copper) 1 Each
45 45 Capillary tube (copper) 1 Each
46 46 Non return valve (For gas top up charging) 1 Each
47 47 Remote control suitable for Non inverter Tower AC. \n 1 Each
48 48 PCB board suitable for outdoor unit. 1 Each
49 49 PCB board suitable for indoor unit. 1 Each
50 50 Copper pipe of size 5/8" for suction line with foam insulation 8 Running Metre
51 51 Copper pipe of size 3/8" for discharge line with foam insulation 8 Running Metre
52 52 Swing Motor for indoor unit\n 1 Each
53 53 Outdoor unit stand 1 Each Set
54 54 Condenser fan motor blade 1 Each Set
55 55 Indoor Motor blower 1 Each
56 56 Supply and fix PVC insulated unsheathed cables of size 4 sqmm 5 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed. 10 Running Metre
57 57 Three phase metal plug top 1 Running Metre
58 58 Supply only the new following items for water cooler 40/80 Litres capacity including testing and commissioning etc complete all as directed.
59 59 Relay unit 3 Each
60 60 PVC float valves , high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15 mm. 3 Each
61 61 Thermostat asssembly 3 Each
62 62 Water tap suitable for water cooler.\n 3 Each
63 63 Starting Capacitor 80-100 MFD 3 Each
64 64 Running capcitor 36 MFD 3 Each
65 65 Condenser fan motor 1.6HP with blade set 3 Each
66 66 Over load protector (OLP) 3 Each
67 67 Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
68 68 Split type AC 1.5 Ton capacity. Make: Bluestar or Voltas /LG/Samsung/Panasonic\n 13 Each
69 69 Split type AC 2.0 Ton capacity. Make: Bluestar or Voltas /LG/Samsung/Panasonic\n 4 Each
70 70 Water cooler 40/80 Litres capacity . Make: Samsung or Voltas /LG/Bluestar\n 3 Each
71 71 Floor standing/Tower AC 3 Ton Capacity. Make : Voltas or LG/Bluestar/Samsung 1 Each
72 72 Repair to stabilizer of capacity 4 or 5 KVA capacity by removing the old / burnt transformer and replaced with new transformer complete all as directed. 15 Each
73 73 Repair to stabilizer by removing the old / burnt relay board suitable for Voltage stabilizer of capacity 4 KVA / 5 KVA capacity 15 Each
74 74 M & L Painting complete with super enamel paint of approved colour for water cooler all as specified and directed. 10 Each Job
75 75 Supply and fix condensed water PVC flexible pipe of standard quality of suitable size fixing with suitable clamps on wall for split type AC of capacity of 1.5/2.0 Ton complete all as specified and as directed. 120 Running Metre
76 76 Supply only R22 /R32 /R410 Gas complete all as specified and directed. 80 KG
77 77 Supply only R134a Gas complete all as specified and directed. 10 KG
78 78 Dismantling and dis connecting carefully the existing split AC 1.5/2.0 Ton capacity after disconnecting the copper pipe and electrical connection, Cleaning the refrigeration system with CO2 and fixing in a new position including, brazing, testing and commissioning complete all as directed for the following cooling appliances :-\nNOTE : The wt of refrigerent used for filling/top up shall be measured and paid under respective item. 10 Each Job
79 79 Supply only 2 nos of 1/2" x 3/8" Foam Heat Insulated Pipe Black for Air Conditioner 30 Each Set
80 80 Materia and lobour for making good of surface with sealing the cavity /hole drilled to facilitate tubing, using white cement/POP and cleaning the surface to match with existing surface complete. 30 Each Job
81 Total in Figures
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail