Supply Installation Testing And Commissioning Of Modular Ups And Its Allied Works In Directorate Of Health Service Thiruvananthapuram , Supply , Installation , Testing And Commissioning Of 40 Kva - Modular Ups - 80Kva Power Cabinet ( 3P-3P& Three Independent Phase Management ) With 40Kva /Kw Power Modules With Horizontal & Vertical Paralleling And Battery Using Minimum 15600Vah Smf Battery ( Minimum 65 Ah Or Above ( For 10-20 M Backup Of 40 Kva Load Ie 40 Kva In . 8 Pf So 32 Kw Load ) With Battery Interconnection , Suitable Battery Rack And Its Accessories Also The Rate Including Snmp Card , Tvss And All Other Specification As Per The Attached Technical Specification . Warranty - 3 Year For Ups And Battery , Supply Of X . L . P . E Insulated 1 . 1 Kv Grade Aluminum Conductor Cable : 4 X 35 Sq . Mm Al , Supply Of Lt End Termination Of 4 X 35 Sq . Mm Al , Supply Of 2 Run 10 Swg Bare Copper , Supply Of 2 Nos Of 4 Sq Mm And 1 Nos Of 2 . 5 Sq Mm Pvc Insulated Copper Wire , Supply Of 35 Sqmm Pvc Insulated Copper Wire , Supply Of Connecting Leg For 35 Sqmm Cu Cable , Supply Of 1 Nos Of 16A Socket Controlled By 1 Switch With Surface Mounted Box - Modular , Supply Of 4 Pole 125 A Mccb With Enclosure And All Accessories , Supply Of 100 A Hrc Fuse , Supply Of 4 Way Double Door 125 A Mccb Vdb With All Accessories , Supply Of 40A 3 Pole Mcb , Supply Of 2 Pole Enclosure Box - Metal , Supply Of 16A Single Pole Mcb , Supply Of All Materials For Plate ( Galvanized Iron ) Earthing As Per Is-3043-1987 , Supply Of Gi/Cu Earthing Conductors Inclusive Of Providing Earthing Terminations And Bracing Of The Terminations Using Necessary Clamps , Screws And Bolts , Pvc Sleeves , Etc . 25X6mm Gi Strip , Supply Of 1 . 5 Ton Five Star Inverter Ac With Sequential Controller And With All Necessary Accessories Including Stand For Mounting Outdoor Unit , Copper Pipe 10 M , Stabilizer Etc And One Year Warranty , Laying Of X . L . P . E Insulated 1 . 1 Kv Grade Aluminum Conductor Cable : 4 X 35 Sq . Mm Al , Fixing Of Lt End Termination Of 4 X 35 Sq . Mm Al , Laying Of 2 Run 10 Swg Bare Copper , Laying Of 2 Nos Of 4 Sq Mm And 1 Nos Of 2 . 5 Sq Mm Pvc Insulated Copper Wire , Laying Of 35 Sqmm Pvc Insulated Copper Wire , Fixing Of Connecting Leg For 35 Sqmm Cu Cable , Fixing Of 1 Nos Of 16A Socket Controlled By 1 Switch With Surface Mounted Box - Modular , Fixing Of 125 A Mccb With Enclosure And All Accessories , Fixing Of 100 A Hrc Fuse , Fixing Of 4 Way Double Door 125 A Mccb Vdb With All Accessories , Fixing Of 40A 3 Pole Mcb , Fixing Of 2 Pole Enclosure Box - Metal , Fixing Of 16A Single Pole Mcb , Fixing Of All Materials For Plate ( Galvanized Iron ) Earthing As Per Is-3043-1987 , Laying Of Gi/Cu Earthing Conductors Inclusive Of Providing Earthing Terminations And Bracing Of The Terminations Using Necessary Clamps , Screws And Bolts , Pvc Sleeves , Etc . 25X6mm Gi Strip , Installation Charge For Air Conditioner , Brick Wall With Cement Brick , Plastering Work Of Wall , 2 Cote Interior White Colour Paint And Fire Rated 2 Leaf Metal Door . Room Size ( Lxwxh ) - ( 5X4x4 ) Meter