Pan City Infrastructure-Integrated Command And Control Centre , Smart Components And Smart Governance .
Tender Overview
Project Description
Pan City Infrastructure-Integrated Command And Control Centre , Smart Components And Smart Governance .
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Dec-2020 | 2nd Revised Corrigendum | Date | 22-Jan-2021 |
| 2 | 19-Jan-2021 | revised dates | Date | 08-Feb-2021 |
| 3 | 28-Jan-2021 | Final Revised Dates | Date | 11-Feb-2021 |
| 4 | 28-Jan-2021 | PRE-BID QUERIES RESPONSE SHEET | Other | 11-Feb-2021 |
| 5 | 11-Feb-2021 | Clarification of Queries | Other | 15-Feb-2021 |
| 6 | 15-Feb-2021 | Revised Dates | Date | 19-Feb-2021 |
BOQ
| Name of Work: Selection of Implementing Agency for Pan city Infrastructure - Integrated Command and Control Centre, Smart Solutions and Smart Governance for SSCL | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | QuantityIndicated | Units | |
| 1 | 1 | Price Component For CAPEX | |||
| 2 | 2 | SITC of Command and Control Centre Setup | |||
| 3 | 3 | Video Wall Solution- 55\" LED (Matrix of 4*3) | item1 | 12 | Number |
| 4 | 4 | Video wall controller with cabling and other fixture and wall management software | item2 | 1 | Lot |
| 5 | 5 | Operator Workstation (CCC and NOC) with 2 monitors (22\") with office productivity suite licenses | item3 | 28 | Number |
| 6 | 6 | Operator Workstation (Helpdesk) with 1 monitor (22\") with office productivity suite licenses | item4 | 10 | Number |
| 7 | 7 | Laptop for higher management with office productivity suite licenses | item5 | 2 | Number |
| 8 | 8 | Network Colour Laser Printer (A3) | item6 | 1 | Number |
| 9 | 9 | Network B/w Laser Printers (A4) | item7 | 2 | Number |
| 10 | 10 | Network B/w Heavy Duty Laser Printers | item8 | 1 | Number |
| 11 | 11 | Multi Function Printer (MFP) | item9 | 2 | Number |
| 12 | 12 | IP Phone | item10 | 51 | Number |
| 13 | 13 | Indoor Fixed Dome Cameras for internal surveillance | item11 | 25 | Number |
| 14 | 14 | Wifi Access for CCC | item12 | 1 | Lot |
| 15 | 15 | Networking Cost (Passive Components such as LAN/CAT 6 Cabling) | item13 | 1 | Lumpsum |
| 16 | 16 | Electrical Cabling & Necessary Illumination Devices for CCC, War Room, Helpdesk room, NOC room, Manager(s) room etc. | item14 | 1 | Lumpsum |
| 17 | 17 | IP PABX for CCC including all accesories | item15 | 1 | Lot |
| 18 | 18 | Digital Set top box | item16 | 2 | Number |
| 19 | 19 | Video Conferencing Unit | item17 | 1 | Number |
| 20 | 20 | 55\" LED display to present critical information Display (War Room) | item18 | 1 | Number |
| 21 | 21 | Microphone with respective accessories | item19 | 15 | Number |
| 22 | 22 | Headphones | item20 | 10 | Number |
| 23 | 23 | PRI Line (Pair) with all necessary accessories | item21 | 1 | Number |
| 24 | 24 | SMS Gateway modem | item22 | 1 | Number |
| 25 | 25 | Any other item to meet the requirements of the RFP | item23 | 1 | Number |
| 26 | 26 | Integrations with CCC | |||
| 27 | 27 | Integration of ICCC with Smart street lighting | item24 | 1 | Lumpsum |
| 28 | 28 | Integration of ICCC with Smart Meters | item25 | 1 | Lumpsum |
| 29 | 29 | Integration of ICCC with Smart Parking | item26 | 1 | Lumpsum |
| 30 | 30 | Integration of ICCC with Intelligent Traffic Enforcement | item27 | 1 | Lumpsum |
| 31 | 31 | Integration of ICCC with City Surveillance System | item28 | 1 | Lumpsum |
| 32 | 32 | Integration of ICCC with Adaptive Traffic Control System (ATCS) | item29 | 1 | Lumpsum |
| 33 | 33 | Integration of ICCC with Environment Sensors | item30 | 1 | Lumpsum |
| 34 | 34 | Integration of ICCC and ERP with GIS | item31 | 1 | Lumpsum |
| 35 | 35 | Integration of ICCC with Variable Messeging Display (VMD) | item32 | 1 | Lumpsum |
| 36 | 36 | Integration of ICCC with Bus Terminal/Stops | item33 | 1 | Lumpsum |
| 37 | 37 | Integration of ICCC with SWM | item34 | 1 | Lumpsum |
| 38 | 38 | Integration of ICCC with SCADA (Water and Sewerage) | item35 | 1 | Lumpsum |
| 39 | 39 | Integration of ICCC with Electric Buses | item36 | 1 | Lumpsum |
| 40 | 40 | Integration of ICCC with additional platform for each additional use case | item37 | 1 | Lumpsum |
| 41 | 41 | SITC of DC Hardware and SITC of Cyber Security | |||
| 42 | 42 | Core Router | item38 | 2 | Number |
| 43 | 43 | Core Switch | item39 | 2 | Number |
| 44 | 44 | L3 Switch | item40 | 1 | Lot |
| 45 | 45 | L2 Switch | item41 | 1 | Lot |
| 46 | 46 | Server load balancer | item42 | 2 | Number |
| 47 | 47 | Networking Cost (Passive Components) | item43 | 1 | Lumpsum |
| 48 | 48 | Internet Router | item44 | 2 | Number |
| 49 | 49 | KVM Switch/Module | item45 | 1 | Number |
| 50 | 50 | 42 U Racks for Networking | item46 | 2 | Number |
| 51 | 51 | 42 U Racks for servers and storage | item47 | 8 | Number |
| 52 | 52 | Online UPS with battery backup | item48 | 1 | Number |
| 53 | 53 | Storage with 2 no. of SAN Switches & Complete mounting accessories | item49 | 1 | Lot |
| 54 | 54 | Storage - Tape Drive & Library | item50 | 1 | Lot |
| 55 | 55 | Blade Servers & Chassis | item51 | 1 | Lot |
| 56 | 56 | Firewall (External) {1+1 in HA Mode} | item52 | 2 | Number |
| 57 | 57 | Firewall (Internal) {1+1 in HA Mode} | item53 | 2 | Number |
| 58 | 58 | Data Loss Protection (DLP) | item54 | 1 | Lot |
| 59 | 59 | Anti - Advanced Persistent Threat (Anti-APT) | item55 | 1 | Lot |
| 60 | 60 | Anti - Distributed Denial of Service (DDoS) | item56 | 1 | Lot |
| 61 | 61 | Security Information and Event Management (SIEM) | item57 | 1 | Lot |
| 62 | 62 | Network Access Control (NAC) including Patch Management | item58 | 1 | Lot |
| 63 | 63 | IDAM Solution (1+1 in HA mode) | item59 | 1 | Lot |
| 64 | 64 | Host Intrusion Prevention System (HIPS) | item60 | 1 | Lot |
| 65 | 65 | Web Application Firewall (WAF) | item61 | 1 | Lot |
| 66 | 66 | Any other item to meet the requirements of the RFP | item62 | 1 | Number |
| 67 | 67 | Data Centre Applications and Software | |||
| 68 | 68 | Enterprise Management System(including SLA Mgmt, Helpdesk Mgmt, Network Mgmt, BMS) + Licenses as required | item63 | 1 | Lot |
| 69 | 69 | Backup software | item64 | 1 | Lot |
| 70 | 70 | Virtualization Software | item65 | 1 | Lot |
| 71 | 71 | DRM (DC-DR Sync) Software | item66 | 1 | Lot |
| 72 | 72 | Anti-virus (Software + License) for workstations | item67 | 40 | Number |
| 73 | 73 | Anti-Virus for Server | item68 | 1 | Lot |
| 74 | 74 | ICCC Software with Perpetual License and unlimited sensors | item69 | 1 | LS |
| 75 | 75 | Call Centre Management (Software + 20 user License) | item70 | 1 | LS |
| 76 | 76 | Video Management Software | item71 | 1 | Number |
| 77 | 77 | Supply & configuration of video management software channel license | item72 | 124 | Number |
| 78 | 78 | Central Management Software for detetcting RLVD, No Helmet and Triple Riding | item73 | 1 | Lot |
| 79 | 79 | Central Management Software for detecting Wrong way | item74 | 1 | Lot |
| 80 | 80 | Central Management Software for detecting Speed violation | item75 | 1 | Lot |
| 81 | 81 | Enterprise violations management system for fines and connectivity with vahan and sarathi for auto vehicle identification and fines registry | item76 | 1 | Lot |
| 82 | 82 | Variable Messaging Display (Software + License) | item77 | 1 | Lot |
| 83 | 83 | Centralized Software for Smart Street Lights (Including Mobile Apps) | item78 | 1 | Lot |
| 84 | 84 | Smart Parking Software including Dashboarding, reporting & Analytic tools | item79 | 1 | Lot |
| 85 | 85 | Smart Parking POS software | item80 | 1 | Lot |
| 86 | 86 | GIS Software Licenses for Servers | item81 | 2 | Number |
| 87 | 87 | GIS Web Server License | item82 | 1 | Number |
| 88 | 88 | GIS Software Licenses for Database Servers | item83 | 1 | Number |
| 89 | 89 | GIS Platform License (server based) | item84 | 1 | Number |
| 90 | 90 | GIS Platform - Desktop (Editing license) | item85 | 3 | Number |
| 91 | 91 | ATCS Software Solution | item86 | 1 | Lot |
| 92 | 92 | Software license for Database server | item87 | 1 | Lot |
| 93 | 93 | Software license per servers | item88 | 1 | Lot |
| 94 | 94 | Software license for web server | item89 | 1 | Lot |
| 95 | 95 | Any Other item required to meet the RFP requirements | item90 | 1 | Number |
| 96 | 96 | Training, Certifications and Audit | |||
| 97 | 97 | Functional Training | item91 | 14 | Batches |
| 98 | 98 | Administrative Training | item92 | 7 | Batches |
| 99 | 99 | Sr. Management Training | item93 | 7 | Batches |
| 100 | 100 | ISO 27K certification | item94 | 1 | Lot |
| 101 | 101 | Security Audit (ISO 27k Audit) | item95 | 1 | Lot |
| 102 | 102 | Enterprise Resource Planning, Mobile Application and Web-portal | |||
| 103 | 103 | Supply and Activation of ERP Licenses | item96 | 90 | Lot |
| 104 | 104 | Implementation Cost for ERP Modules | item97 | 1 | Lumpsum |
| 105 | 105 | Integration Cost for E-Gov Solution | item98 | 1 | Lumpsum |
| 106 | 106 | Integration with GIS | item99 | 1 | Lumpsum |
| 107 | 107 | Integration with Biometric Attendance System | item100 | 1 | Lumpsum |
| 108 | 108 | Development/ Implementation Cost for Web Portal & Mobile App | item101 | 1 | Lot |
| 109 | 109 | Scanning of documents | item102 | 1 | Lumpsum |
| 110 | 110 | Any Other item required to meet the RFP requirements | item103 | 1 | Number |
| 111 | 111 | GIS | |||
| 112 | 112 | Satellite Image | item104 | 18 | Sq. Kilometer |
| 113 | 113 | Processing of Satellite Imagery and Digitization | item105 | 18 | Sq. Kilometer |
| 114 | 114 | Customized GIS Application Development For Water Supply, Storm Water, Sewer, OFC, Gas and Electricity Departments | item106 | 1 | Lumpsum |
| 115 | 115 | Underground utilities survey | item107 | 122 | Kilometer |
| 116 | 116 | Any Other item required to meet the RFP requirements | item108 | 1 | Number |
| 117 | 117 | SITC of Active components, SLTC of Passive components & Junctionbox including Earthing | |||
| 118 | 118 | Access Switch L2 Industrial Grade with SFP and Patch Cord | item109 | 72 | Number |
| 119 | 119 | Fibre Patch cords 20 metres | item110 | 55 | Units |
| 120 | 120 | SITC of Electricity Metres at Junction Boxes | item111 | 55 | Units |
| 121 | 121 | SITC of Field Junction Box/Cabinets for all field components of project | item112 | 55 | Number |
| 122 | 122 | SITC of Online field UPS with Battery Bank for 2 hours | item113 | 55 | Number |
| 123 | 123 | SLTC of HDPE Pipe - 50 mm | item114 | 5500 | Mtr. |
| 124 | 124 | SLTC of HDPE Pipe - 90 mm | item115 | 5500 | Mtr. |
| 125 | 125 | SLTC of DWC Pipe - 90 mm | item116 | 5500 | Mtr. |
| 126 | 126 | SLTC of DWC Pipe - 120 mm | item117 | 5500 | Mtr. |
| 127 | 127 | SLTC of Electrical Cable - 3 Core,2.5 Sqmm Unarmoured Cable | item118 | 100 | Mtr. |
| 128 | 128 | SLTC of Electrical Cable - 3 Core,2.5 Sqmm armoured Cable | item119 | 250 | Mtr. |
| 129 | 129 | SLTC of Electrical Cable - 7 Core,1.5 Sqmm Armoured Cable | item120 | 5000 | Mtr. |
| 130 | 130 | SLTC of Electrical Cable - 14 Core,1.5 Sqmm Armoured Cable | item121 | 2500 | Mtr. |
| 131 | 131 | Removing of existing poles, pole Foundations,Aspects,Damaged Cables,Existing Controller & Shifting to the location as per guideliance of Authority. | item122 | 50 | Mtr. |
| 132 | 132 | Trenching - Hard Murrum/Asphalt Road | item123 | 2750 | Mtr. |
| 133 | 133 | Trenching - HDD | item124 | 2750 | Mtr. |
| 134 | 134 | Leased Line Connectivity | |||
| 135 | 135 | One Time Charge for Leased Line bandwidth of 2 Mbps Link Between ICCC and end remote locations | item125 | 16 | Number |
| 136 | 136 | One Time Charge for Leased Line bandwidth of 5 Mbps Link Between ICCC and end remote locations | item126 | 3 | Number |
| 137 | 137 | One Time Charge for Leased Line bandwidth of 10 Mbps Link Between ICCC and end remote locations | item127 | 1 | Number |
| 138 | 138 | One Time Charge for Leased Line bandwidth of 20 Mbps Link Between ICCC and end remote locations | item128 | 24 | Number |
| 139 | 139 | One Time Charge for Leased Line bandwidth of 30 Mbps Link Between ICCC and end remote locations | item129 | 82 | Number |
| 140 | 140 | One Time Charge for Leased Line bandwidth of 40 Mbps Link Between ICCC and end remote locations | item130 | 1 | Number |
| 141 | 141 | One Time Charge for Leased Line bandwidth of 50 Mbps Link Between ICCC and end remote locations | item131 | 4 | Number |
| 142 | 142 | One Time Charge for Leased Line bandwidth of 20 Mbps Link between DC and checkpost locations | item132 | 6 | Number |
| 143 | 143 | Any Other item required to meet the RFP requirements | item133 | 1 | Number |
| 144 | 144 | Traffic Enforcement and Surveillance | |||
| 145 | 145 | SITC of Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 8 lanes (2 Lanes in each arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illuminator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item134 | 12 | Traffic Junction |
| 146 | 146 | SITC of Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 3 arms & 6 lanes (2 lanes in each Arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item135 | 4 | Traffic Junction |
| 147 | 147 | SITC of Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 6 lanes (2 Lanes in 2 Arms each and 1 lane in remaing 2 Arms each) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item136 | 1 | Traffic Junction |
| 148 | 148 | SITC of Speed Detection System for covering 2 lanes in one direction with complete subcomponents including ANPR camera, wide angle evidence camera, IR illuminator, non intrusive speed sensor with cabling & mounting infrastructure as required | item137 | 20 | Location |
| 149 | 149 | SITC of ANPR System for capturing number plates at 2 arms and 4 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item138 | 5 | Location |
| 150 | 150 | SITC of ANPR System for capturing number plates at 2 arms and 6 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item139 | 6 | Location |
| 151 | 151 | SITC of \"Wrong way detection\" System covering 1 arm and 1 lane at each Location with complete hardware including ANPR camera, cabling, accessories and mounting infrastructure as required | item140 | 8 | Location |
| 152 | 152 | SITC of Traffic Surveillance PTZ Cameras System with Complete mounting accessories as required | item141 | 6 | Number |
| 153 | 153 | SITC of Traffic Surveillance Overview/Fixed box Cameras System with required Hardware and Softwae including Local Processing Unit, cabling, accessories & mounting infrastructure as required | item142 | 122 | Number |
| 154 | 154 | SETC of Poles for Cameras and Equipments | item143 | 42 | Number |
| 155 | 155 | E-Challan Handheld Device including Software | item144 | 15 | Number |
| 156 | 156 | SITC of Active and Passive Components for Surveillance in Buildings | |||
| 157 | 157 | Indoor Fixed Dome Cameras for internal surveillance | item145 | 420 | Number |
| 158 | 158 | 2 Megapixel Full HD IR IP Vandal proof Bullet Camera with Varifocal Lens | item146 | 140 | Number |
| 159 | 159 | 8 channel Network Video Recorder (NVR) | item147 | 70 | Number |
| 160 | 160 | 32\" LED display | item148 | 70 | Number |
| 161 | 161 | Video Channel License | item149 | 560 | Number |
| 162 | 162 | 8 Port Managed PoE/PoE+ Network switch | item150 | 70 | Number |
| 163 | 163 | SFP (1G) Short haul | item151 | 140 | Number |
| 164 | 164 | Fibre Patch cords 2 metres | item152 | 140 | Units |
| 165 | 165 | Networking (CAT6) cable | item153 | 28000 | Mtr. |
| 166 | 166 | Flexible Power cables 3 core, 1.5 sq. mm copper cable | item154 | 28000 | Mtr. |
| 167 | 167 | PVC Pipe 22 mm diameter | item155 | 21000 | Mtr. |
| 168 | 168 | UPS with 1 hour backup | item156 | 70 | Number |
| 169 | 169 | 9U Rack | item157 | 70 | Number |
| 170 | 170 | Any Other item required to meet the RFP requirements | item158 | 1 | Number |
| 171 | 171 | SITC of Adaptive Traffic Control System | |||
| 172 | 172 | SITC of ATCS Traffic Controller with all mounting accessaries | item159 | 17 | Number |
| 173 | 173 | SITC of Countdown timer (CDT) with all mounting accessaries | item160 | 126 | Number |
| 174 | 174 | SITC of Vehicle Detector Camera with all mounting accessaries | item161 | 63 | Number |
| 175 | 175 | SETC of Cantilever poles | item162 | 63 | Number |
| 176 | 176 | SETC of Standard poles for Traffic Signals | item163 | 97 | Number |
| 177 | 177 | SITC of 300 mm dia polycarbonate signal heads including aspect with LED based capsule, visor bracket frame works, Supports, flexible wires,Wires glands and pipes etc | |||
| 178 | 178 | SITC of Traffic Light Aspects - Red | item164 | 189 | Number |
| 179 | 179 | SITC of Traffic Light Aspects - Green (Green Straight, Green Right, Green Left) | item165 | 531 | Number |
| 180 | 180 | SITC of Traffic Light Aspects - Amber | item166 | 189 | Number |
| 181 | 181 | SITC of Pedestrian lamp heads - Stop & Walk Man | item167 | 126 | Number |
| 182 | 182 | SITC of Electrical Cable | |||
| 183 | 183 | SITC of 3 Core,2.5 Sqmm Unarmoured Cable | item168 | 100 | Meter |
| 184 | 184 | SITC of 3 Core, 2.5 Sqmm Armoured Cable | item169 | 250 | Meter |
| 185 | 185 | SITC of 7 Core, 1.5 Sqmm Armoured Cable | item170 | 5000 | Meter |
| 186 | 186 | SITC of 14 Core, 1.5 Sqmm Armoured Cable | item171 | 2500 | Meter |
| 187 | 187 | Removing of existing poles, pole Foundations,Aspects,Damaged Cables,Existing Controller & Shifting to the location as per guidlince of Authority. | item172 | 50 | Number |
| 188 | 188 | Any Other item required to meet the RFP requirements | item173 | 1 | Number |
| 189 | 189 | Variable Messaging Display and Environmental sensors | |||
| 190 | 190 | SITC of VMD (3 x 1.5m) with Audio enabled and VMD Controller | item174 | 4 | Number |
| 191 | 191 | Installation, Testing, Commissioning of Poles for VMD (3 x 1.5m) (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display | item175 | 4 | Number |
| 192 | 192 | SITC of VMD (8 x 3m) with Audio enabled and VMD Controller | item176 | 7 | Number |
| 193 | 193 | Installation, Testing, Commissioning of Poles for VMD (8 x 3m) (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display | item177 | 7 | Number |
| 194 | 194 | SITC of Environtal sensors | item178 | 2 | Number |
| 195 | 195 | Any Other item required to meet the RFP requirements | item179 | 1 | Number |
| 196 | 196 | Smart Street Lights | |||
| 197 | 197 | SITC of street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 6 LED Fixures to be made smart & communicable to City’s Command and Control Centre (CCC), as per tender specifications. | item180 | 17 | Number |
| 198 | 198 | SITC of street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 8 LED Fixures to be made smart & communicable to City’s Command and Control Centre (CCC), as per tender specifications | item181 | 11 | Number |
| 199 | 199 | SITC of street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 12 LED Fixures to be made smart & communicable to City’s Command and Control Centre (CCC), as per tender specifications. | item182 | 6 | Number |
| 200 | 200 | SITC of street light Controller & dimming driver for existing functional LED Street Lights 100W to 300W each on Single/ Double/ Triple poles with capability to handle/ control the min 10 Nos to Max 100 Nos of LED Street Light Poles per feeder panel, to be made smart & communicable to City’s Command and Control Centre (CCC), as per tender specifications. | item183 | 104 | Number |
| 201 | 201 | Any Other item required to meet the RFP requirements | item184 | 1 | Number |
| 202 | 202 | SITC of Street Bay Parking Management system - Street Bay Parking | |||
| 203 | 203 | Magenetic sensor surface mount | item185 | 325 | Number |
| 204 | 204 | SITC of Networking/Communication for magnetic sensors including all necessary cablings and accessories | item186 | 7 | Lot |
| 205 | 205 | Handheld device with scanner and printer with 8 hrs battery backup at full load with networking capability to command centre or Mobile POS device | item187 | 15 | Number |
| 206 | 206 | Any Other item required to meet the RFP requirements | item188 | 1 | Number |
| 207 | 207 | Non-ICT Components - Architecture Works | |||
| 208 | 208 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). | item189 | 34.53 | Cum |
| 209 | 209 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. | item190 | 3.49 | Cum |
| 210 | 210 | Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering up to floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) | item191 | 322.32 | Sqm |
| 211 | 211 | Applying two coats of Birla (white cement based) or Asian (acrylic lapy- putty) or equivalent & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. | item192 | 322.32 | Sqm |
| 212 | 212 | Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. | item193 | 746.05 | Sqm |
| 213 | 213 | Distempering (Two coats) with oil bound distemper of approved brand and manufacture and of required shade on wall surfaces to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth. | item194 | 606.87 | Sqm |
| 214 | 214 | P & L 24\" x 24\" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismantling of existing flooring and jointed with color cement slurry including finished with flush pointing & cleaning the surface etc. complete for light shade (upto 10 ton) | item195 | 151.14 | Sqm |
| 215 | 215 | Laminated Wooden Flooring or Carpet :\nProviding and laying in position 8mm thick laminated wooden flooring AC4 semi commercial use at desired locations including steps ,Riser with edge protector and skirting as per the patterns/ designs of the consultants of Pergo, Tarkett, Eurofloor, Quickstep, Armstrong, Beautex, Egger. The samples shall be approved by the consultants prior to laying. The wooden floor shall be laid over a company made underlay felt and underlay foam leveller. The sides of the wooden flooring shall be firmly secured against uplift with the use of company made skirting and edge profiles. The profile sections shall be approved by the engineer-in-charge prior to use. in complete. | item196 | 235.2 | sqm |
| 216 | 216 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. | item197 | 700.01 | sqm |
| 217 | 217 | 12.54 -Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with \n12.54.2 -GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. | item198 | 60.2 | sqm |
| 218 | 218 | Providing & fixing glazing panels & doors using 12mm thk toughened, float, clear glass of Asahi or approved equivalent make with crystal edge polish (conforming to ASTM Standards C-1048) supported by S.S. patch fittings (Sevax Olivier or approved equivalent) at the bottom, top & side edge and inter- connecting patch fittings between glass panels, stainless steel articulated countersunk bolts threaded bolts, chemical fasteners, etc. glass panel size as per design and drawing including applying colourless sealant of joint incl. required edge polish, making glazing water tight, etc. Destructive node joint test reports to be submitted for establishing the safety factor. Including operating hardware,SS patch fittings, fabricated long length satin finish SS 316 door handles, patch lock, floor springs etc.complete as directed by the architect for frameless patch doors,single or twin leaf shutters with fixed panel on top. (All hardware: as specfied ) Item to include making & fixing necessary 37.5 x 50mm BTC rigid framework above the false ceiling for fixing the angle part of the internal glass partitions and glass doors at the top as per architectural detail drawing including all hardware complete. | item199 | 64.14 | sqm |
| 219 | 219 | 9.20- Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.\n9.20.1-35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws | item200 | 17.64 | sqm |
| 220 | 220 | 9.105 -Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.\n\n9.105.1-75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: (part 3) : 1996 (Board with BIS certification marks) | item201 | 132.75 | sqm |
| 221 | 221 | Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge. | item202 | 132.75 | sqm |
| 222 | 222 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded). | item203 | 12 | Mtr. |
| 223 | 223 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately). | item204 | 6.3 | sqm |
| 224 | 224 | 26.24 Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer’s specification as per direction of Engineer-in-Charge all complete.\n\n26.24.1 With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles | item205 | 188.97 | sqm |
| 225 | 225 | 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.\n11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. | item206 | 5 | sqm |
| 226 | 226 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. | item207 | 166 | sqm |
| 227 | 227 | Providing and fixing roller blinds with drive unit end plug support brackets roller tube bottom rail ball chains all described as below but with fabric of approved shade colour and sample.Drive unit to be of moulded plastic with straight rectangle support pin and inserted into the tube end. It shall be driven by a ball chain pully and can be positioned at right or left side of the shade. The shade when lowering or raising shall automatically be lockable from release of the ball chain by means of friction lock. End plug shall be moulded to plastic locking pin. The plug shall be inserted into the tube end. Support brackets shall be of zinc plated steel and provided with moulded plastic covers and used in right of left hand positions differentiated by acceptance of the rectangular drive unit support or the ground idler plug pin. Roller tube shall be made out of roll formed steel of thickness suitably protected against corrosion and keyway integrated with the tube to accommodate the spline, outside diameter of the roller tube shall be 25mm. Bottom rail shall be stiffening element inserted into the bottom rod pocket. Tube to be of the material as approved out of timber, PVC, Steel of VB Bottom rail. Ball chain shall be of 2mm dia cord with actual balls moulded coaxially to it on 6mm pitch to form ball chain.Make - Vista / Hunter douglas | item208 | 114.76 | sqm |
| 228 | 228 | Wall Paper-Providing and fixing anti bacterial / anti microbial, ISO 22196 (JIS Z2801) rated, durable water resistant, fire retardant, PVC wall paper (Bio Hygienic) of approved shade with recommended adhesive of approved make and sample as per manufacturer's specifications . Cost to include preparation on the punned surface for receiving the Poster as per the manufacturer specification. Basic cost of wall paper at Rs. 1400 /Sqm. Item to include base finish preparation in line & level. | item209 | 238.43 | sqm |
| 229 | 229 | Providing and fixing 3M make Scotchal 7725 Series Frosted film on Glass Partition and glass door with MCS warranty as per the manufacturer specification. | item210 | 50 | Sqm |
| 230 | 230 | Signage's-Providing and fixing 1.5mm Anti- Corrosive Brushed SS Plate Engraved Room Name & Number, size 300mmx100mm.As per samples approved by E-in -Charge. | item211 | 30 | Nos |
| 231 | 231 | DEMOLITION & DISMANTLING_Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. | item212 | 151.14 | Sqm |
| 232 | 232 | DEMOLITION & DISMANTLING_Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar. | item213 | 20 | Cum |
| 233 | 233 | DEMOLITION & DISMANTLING_Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work | item214 | 10 | Cum |
| 234 | 234 | INDOOR PLANTERS_Supply of Palms and indoor plant - well developed, polybag, disease free. Acceptable tolerances to variations in stem height shall be +100mm or -100mm from the height specified in the Bills of Quantities. The heads of palms and plants shall be well balanced and a healthy growing apical shoot all free from pest and disease. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust. All Season indoor Areca Palm (1.2m Height) | item215 | 10 | Nos |
| 235 | 235 | INDOOR PLANTERS_Supply of Palms and indoor plant - well developed, polybag, disease free. Acceptable tolerances to variations in stem height shall be +100mm or -100mm from the height specified in the Bills of Quantities. The heads of palms and plants shall be well balanced and a healthy growing apical shoot all free from pest and disease. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust. Nature Cycas Revoluta Sago Palm (0.6m Height) | item216 | 3 | Nos |
| 236 | 236 | INDOOR PLANTERS_Supply of Palms and indoor plant - well developed, polybag, disease free. Acceptable tolerances to variations in stem height shall be +100mm or -100mm from the height specified in the Bills of Quantities. The heads of palms and plants shall be well balanced and a healthy growing apical shoot all free from pest and disease. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust.\nDieffenbachia 'Camilla' - Plant (0.9 m Height) | item217 | 5 | Nos |
| 237 | 237 | INDOOR PLANTERS_Supply of Palms and indoor plant - well developed, polybag, disease free. Acceptable tolerances to variations in stem height shall be +100mm or -100mm from the height specified in the Bills of Quantities. The heads of palms and plants shall be well balanced and a healthy growing apical shoot all free from pest and disease. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust.\nDieffenbachia 'Tropic Snow' - Plant (1.2 m Height) | item218 | 5 | Nos |
| 238 | 238 | supply and installation of Round Decoration Fancy Plastic Flower Pots(0.3 to .45 Height and size Suitable for indoor plants) | item219 | 23 | Nos |
| 239 | 239 | DUSTBIN_Supply of Stainless Steel Plain Pedal Dustbin, Garbage Bin with Removable Bucket Round Shape 8''x12'' - 5 liters, Silver Color Slim and Fingerprint-Proof Finish. | item220 | 5 | Nos |
| 240 | 240 | DUSTBIN_Supply of Stainless Steel Dustbin Round Semi Perforated ( 9\" x 14\") | item221 | 10 | Nos |
| 241 | 241 | Any other item as per requirement mentioned in the RFP | item222 | 1 | Number |
| 242 | 242 | Non-ICT Components - Civil Works | |||
| 243 | 243 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. | item223 | 18.98 | cum |
| 244 | 244 | Raised False Floor with 600x600mm tiles-\nProviding and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of:\n(a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.\n(b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.\n(c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.\n450 mm Finished Floor Height (FFH). | item224 | 180.67 | Sqm |
| 245 | 245 | Strengthening of Ground floor Slab with Steels joist/Beam-\nProviding , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete. | item225 | 870.98 | kg |
| 246 | 246 | Extra for Supply of Hiti Bolts M16-4500 Lng -HIT-V(5.8) with Hiti adhesive -RE 500 V3 | item226 | 32 | Nos |
| 247 | 247 | RCC-Tie Beam -\nProviding and laying controlled cement concrete M.200 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete (upto 10 ton) | item227 | 1.478 | cum |
| 248 | 248 | Formwork -Tie Beam -\nProviding formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams Beam Haunchings cantilevers Girders Bressumers and Lintels not exceeding 1 M. in Depth. (upto 10 ton) | item228 | 16.61 | sqm |
| 249 | 249 | Reinforcement-\nProviding TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level (upto 10 ton) | item229 | 73.9 | kg |
| 250 | 250 | Excavation-Manual Labour-\nExcavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense or Hard soil | item230 | 46.2 | Cum |
| 251 | 251 | 100mm Thk. PCC- \nProviding and laying cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (upto 10 ton) | item231 | 1.68 | Cum |
| 252 | 252 | CONCRETE BLOCK MASONRY (250mm Thk)-\nPrecast concrete block masonry (including quoin blocks jamb blocks closer etc.) with solid concrete blocks of approved size made of cement concrete 1:3:6 mix (1- Cement : 3 coarse sand: 6- graded stone aggregates of 20 mm and down grade) in foundation and plinth cement morter 1:6 (upto 10 ton) | item232 | 10.8 | Cum |
| 253 | 253 | Filling in CSS Pedestal-\nFilling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete. (upto 10 ton) | item233 | 33.75 | Cum |
| 254 | 254 | RCC-Slab For Top-\nProviding and laying controlled cement concrete M.200 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete (upto 10 ton) | item234 | 6.75 | Cum |
| 255 | 255 | Slab Edges-Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (I) Edges of slabs and Breaks in floors and walls. (upto 10 ton) | item235 | 14.4 | Sqm |
| 256 | 256 | CM Plaster-\n20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete. | item236 | 14.4 | Sqm |
| 257 | 257 | Reinforcement-\nProviding TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level (upto 10 ton) 70kg/Cum of concrete | item237 | 472.5 | Kg |
| 258 | 258 | Any other item to meet the requirements of the RFP | item238 | 1 | Number |
| 259 | 259 | Non-ICT Components - Electrical Works | |||
| 260 | 260 | Design,Supply, Installation, Testing and Commissioning of Ring Main Unit (RMU), Compact Sub-Station (CSS) including miscellaneous electrical and civil works for Control and command centre with all material and labour etc as per required specifications stated in tender documents and as Planning and design approved by SSCL, including all taxes, charges, royalties, etc. complete. Item shall be complete in all respect to the satisfaction of engineer in charge. For further details bidders should refer tender drawings and tender document. | item239 | 1 | Lumpsum |
| 261 | 261 | Design,Supply, Installation, Testing and Commissioning of Diesel Generator Set with AMF Panel along with acoustic enclosure including miscellaneous electrical and civil works for Control and command centre with all material and labour etc as per required specifications stated in tender documents and as Planning and design approved by SSCL, including all taxes, charges, royalties, etc. complete. Item shall be complete in all respect to the satisfaction of engineer in charge. For further details bidders should refer tender drawings and tender document. | item240 | 1 | Lumpsum |
| 262 | 262 | Design,Supply, Installation, Testing and Commissioning of Automatic Power Factor Correction Panel (APFC) including miscellaneous electrical and civil works for Control and command centre with all material and labour etc as per required specifications stated in tender documents and as Planning and design approved by SSCL, including all taxes, charges, royalties, etc. complete. Item shall be complete in all respect to the satisfaction of engineer in charge. For further details bidders should refer tender drawings and tender document. | item241 | 1 | Lumpsum |
| 263 | 263 | Design,Supply, Installation, Testing and Commissioning of LT PCC Panel, Power Distribution Boards, Sub Distribution Boards, Raw Power Distribution Boards, Lighting Panels, Receptacle Panels including miscellaneous electrical and civil works for Control and command centre with all material and labour etc as per required specifications stated in tender documents and as Planning and design approved by SSCL, including all taxes, charges, royalties, etc. complete. Item shall be complete in all respect to the satisfaction of engineer in charge. For further details bidders should refer tender drawings and tender document. | item242 | 1 | Lumpsum |
| 264 | 264 | Design, Manufacture, Supply, Installation, Testing and Commissioning of UPS of required capacities, UPS power distribution panels, UPS distribution boards, Batteries including miscellaneous electrical and Civil works required for it, for Control and command centre with all material and labour etc as per required specifications stated in tender documents and as Planning and design approved by SSCL, including all taxes, charges, royalties, etc. complete.Item shall be complete in all respect to the satisfaction of engineer in charge. For further details bidders should refer tender drawings and tender document. (For Desktop/ Workstation). | item243 | 1 | Lumpsum |
| 265 | 265 | Design, Manufacture, Supply, Installation, Testing and Commissioning of UPS of required capacities, UPS power distribution panels, UPS distribution boards, Batteries including miscellaneous electrical and Civil works required for it, for Control and command centre with all material and labour etc as per required specifications stated in tender documents and as Planning and design approved by SSCL, including all taxes, charges, royalties, etc. complete. Item shall be complete in all respect to the satisfaction of engineer in charge. For further details bidders should refer tender drawings and tender document. (For Emergency Illumination). | item244 | 1 | Lumpsum |
| 266 | 266 | Design, Supply, Installation, Testing and Commissioning of Internal/ External HT & LT Electrical works like Cabling, Point wiring and Cable termination, Cable trays, Raceways including miscellaneous electrical and Civil works required for it, for Control and command centre with all material and labour etc as per required specifications stated in tender documents and as Planning and design approved by SSCL, including all taxes, charges, royalties, etc. complete. Item shall be complete in all respect to the satisfaction of engineer in charge. For further details bidders should refer tender drawings and tender document. | item245 | 1 | Lumpsum |
| 267 | 267 | Design, Supply, Installation, Testing and Commissioning of Indoor Light fixture, Receptacle and other electrical accessories including miscellaneous electrical and Civil works required for it, for Control and command centre with all material and labour etc as per required specifications stated in tender documents and as Planning and design approved by SSCL, including all taxes, charges, royalties, etc. complete. Item shall be complete in all respect to the satisfaction of engineer in charge. For further details bidders should refer tender document.. | item246 | 1 | Lumpsum |
| 268 | 268 | Design,Supply, Installation, Testing and Commissioning of Internal LT Electrical works like Earthing and Lightning protection of the electrical equipments and other material required for completion of work including miscellaneous electrical and Civil works required for it, for Control and command centre with all material and labour etc as per required specifications stated in tender documents and as Planning and design approved by SSCL, including all taxes, charges, royalties, etc. complete. Item shall be complete in all respect to the satisfaction of engineer in charge. For further details bidders should refer tender document. | item247 | 1 | Lumpsum |
| 269 | 269 | Any other item to meet the requirements of the RFP | item248 | 1 | Number |
| 270 | 270 | Non-ICT Components - Fire Fighting | |||
| 271 | 271 | Supply & installation of following type of portable fire extinguisher system as per IS 2190 & 15683.\nDry Chemical Powder Fire Extinguisher 6 Kg capacity | item249 | 8 | Number |
| 272 | 272 | Supply & installation of following type of portable fire extinguisher system as per IS 2190 & 15683.\nCarbon dioxide (CO2) Fire Extinguisher 4.5 Kgs capacity | item250 | 22 | Number |
| 273 | 273 | Supply and installation of Gas Suppression System Components (Novec-1230) for Data center and command and control center. (1 lot for Data center and 1 lot for control center) | item251 | 1 | Lot |
| 274 | 274 | Any other item to meet the requirements of the RFP | item252 | 1 | Number |
| 275 | 275 | Non-ICT Components - HVAC | |||
| 276 | 276 | Design, manufacture, supply, installation, testing and commissioning of Microprocessor based single /double skinned Precision Air conditioning unit (For Data Centre) with R410a/R407c Refrigerant having Top/ Bottom suction indoor unit, air-cooled outdoor condensing unit with fan. Indoor unit consists of filter section, P-I-D Controller, multi rows deep copper cooling coil with aluminium fins, dehumidification cycle, modular panel cabinet construction, cabinet insulation, fan section with dynamically balanced centrifugal fans with motor and drive, high technology scroll compressor, accessible refrigeration control, interconnected refrigerant piping, drain piping, electricals etc.\n6 TR (4,500 CMH) | item253 | 2 | Number |
| 277 | 277 | Design, manufacture, supply, installation, testing and commissioning of ceiling suspended rectangular in-line fan with motor of following capacity with ductwork complete with starter panel, wire mesh etc. with all other accessories. (For Toilets at Gr & 3rd Floors) \nCapacity: 1,000 CMH, 15 mm WC | item254 | 2 | Number |
| 278 | 278 | Design, manufacture, supply, installation, testing and commissioning of wall mounted propeller exhaust air fan with motor of following capacity complete with starter panel, wire mesh etc. with all other accessories. (For Small Toilets at Gr & 3rd Floors)\nCapacity: 250 CMH, Free air delivery | item255 | 2 | Number |
| 279 | 279 | GI site fabricated rectangular ducts, complete with MS frame structure and necessary supports using thread roads (as per IS:655) and anchor bolts, exhaust air collars, vanes, splitters dampers for Air-conditioning & Toilet Exhaust Ventilation System. \n22 G GI Ducting | item256 | 15 | SqM |
| 280 | 280 | GI site fabricated rectangular ducts, complete with MS frame structure and necessary supports using thread roads (as per IS:655) and anchor bolts, exhaust air collars, vanes, splitters dampers for Air-conditioning & Toilet Exhaust Ventilation System. \n24 G GI Ducting | item257 | 40 | SqM |
| 281 | 281 | Design, manufacture, supply, installation, testing and commissioning of extruded aluminium powder coated fixed blade type diffusers without VCD, as required. (For Toilet Exhaust Ventilation System + AC Return air grilles) | item258 | 2 | SqM |
| 282 | 282 | Design, manufacture, supply, installation, testing and commissioning of extruded aluminium powder coated fixed blade type intake air louvres, as required. (For Ventilation System) | item259 | 1 | SqM |
| 283 | 283 | Design, manufacture, supply, installation, testing and commissioning of extruded aluminium powder coated diffusers & grilles with VCD, as required. (For Air-conditioning System) | item260 | 1 | SqM |
| 284 | 284 | Design, manufacture, supply, installation, testing and commissioning of GI volume control duct dampers, as required. | item261 | 1 | SqM |
| 285 | 285 | Supply & fixing of Thermal insulation on the Sheet Metal Duct with Factory Pasted Al. Foil Faced Fire retardent 13 mm thick Closed Cell Nitrile Rubber Insulation with necessery Adhesive as recommended by the Manufacturer. | item262 | 45 | SqM |
| 286 | 286 | Supply and fixing of Acoustic insulation with 25mm thick Open Cell Nitrile Rubber with necessery Adhesive as recommended by the Manufacturer. | item263 | 10 | SqM |
| 287 | 287 | Necessary modification work of the existing ductwork at Ground & 3rd floors along with relocation of Indoor units, as required based on latest internal layout drawings. | item264 | 1 | Lot |
| 288 | 288 | Any other item to meet the requirements of the RFP | item265 | 1 | Number |
| 289 | 289 | Non-ICT Components - Furniture | |||
| 290 | 290 | Command Center Workstation Furniture and Fixtures\nProviding & Supplying BIFMA certified godrej wipro and equivalent Wish Penta workstation of size 1500W1 x 750D. Panel thickness-52.4mm. Uprights and horizontals shall be made of aluminum extrusion having material AL96063-T6 & have average wall thickness of 1.2 mm & powder coated with epoxy-polyester powder. Fabricated bottom frame for 52.4mm shall comprise of L- Channels made of 2mm thick CRCA steel (IS:513), formed plates of 3mm thick HR steel (IS:2062) & ERW steel tube of size 35x15x1.6mm in oval cross section (IS:7138) welded together. This shall be coated with average 50 to 60 micron thickness of epoxy powder coating. This shall be bolted to the uprights with M6 screws. A block for 52.4mm panel’s thickness shall comprise of 38mm thick paper honeycomb with 3mm MDF on each sides and 0.6mm decorative laminate or fabric on both sides. Particle board framing shall be used on outer boundary of these blocks as well as intermediately at certain locations forming conduit for passing cables. These blocks (2nos.) will be located in the middle bands of the panels. The panel legs used for supporting panels. The height of a panel leg shall be 126mm. Panel legs shall be fabricated by CO2 welding MS Tube of section 38 mm x 25 mm (IS: 7138 ERW Tube) with the base plate of the MS plate of 35x22x5mm (IS: 2062, 5 mm HR) over which an M8 Leveler shall be fitted, which allows for adjustment of the height by 50mm. It will be coated with min. 45 micron thickness of epoxy powder coating. The single side legs shall be used for supporting panels & work surface on one side only. Single side legs shall be fabricated by CO2 welding MS Tube of section 38 mm x 25 mm (IS: 7138 ERW Tube) with the base plate of the MS plate of 35x22x5mm (IS: 2062, 5 mm HR) over which an M8 Leveler shall be fitted, which shall allow for adjustment of the height by 50mm. this shall be coated with min. 45 micron thickness of epoxy powder coating. Gable end panel shall be made of 18mm thick both side Pre laminated particle board of interior grade of approved shade conforming to IS: 12823. All the edges of panel shall be provided with machine pressed 2 mm thick PVC lipping glued with hot melt EVA glue. Cable duct shall be made from 0.8 mm thick M.S. CRCA Grade D as per IS: 513 - 1994. It is constructed with two parts, one is body & another is cover. It holds the cables & gives aesthetic appearance by covering all cables entry, which are moving upward to the panels. Size of Cable duct is 107mm W X 154 mm H X 21 mm D. TOP TILES: These tiles shall be slid in to the panels from top before fixing the top horizontal. These tiles shall be supported from top & bottom side with clips made from PP co polymer fitted in horizontal extrusion. Fabric magnetic tiles shall be fabric upholstered metal tiles in 0.6 mm thick G.I. Grade O as per IS: 277. The fabrics shall be upholstered with adhesives. Fabric tackable tiles shall be upholstered metal tiles in 0.6mm thick G.I. grade O as per IS: 277, with P.E. foam in the tile for tackablity. The fabric shall be upholstered with adhesives. White board tiles shall be made of 8.0 mm thick particle board conforming to IS: 12823 laminated with 0.6mm thick white glossy high pressure laminate on outer side & 0.6mm backing laminate on inner surface and will be having all its edges with minimum 0.5 mm thick PVC edging. BOTTOM TILES: All bottom tiles shall be press fitted on to the assembly frame of the panel with the help of snap on clips made of nylon-66 and support clips made from PP polymer. Plain Metal tiles shall be powder coated metal tiles in 0.8 mm thick M.S. CRCA Grade D as per IS: 513. ALUMINUM EXTRUSIONS: The top trims and end trims for 52.4 mm & 22.8 mm shall be made from aluminum extrusion having material AL96063-T6. All kinds of extrusions for 52.4 mm and 22.8 mm shall have average wall thickness of 1.2 mm & having finish of powder coating. Top trim in 52.4mm thick panel shall be press fitted on the horizontal extrusion & in 22.8mm thick panel it shall be slide fitted with the help of top trim connector made from PP copolymer 3530 grade. End trim for 52.4mm thick panel shall be slide fitted with the help of end trim connector made from 2.0mm thick M.S. CRCA Grade D as per IS: 513. End trim for 22.8 mm thick panel shall slide with the help of end trim connector made from nylon-66. STABILITY POST: End stability post shall be fitted at the end of the free panel, to avoid movement of freestanding panels. The post shall be made in two parts. 1. The MS post which shall be grouted to the floor with Hilti make anchor bolts. 2. A cover extrusion of aluminium alloy shall cover the grouted MS stability bracket. The top end of the extrusion shall be covered with a powder coated aluminum cap. PANEL JOINERY POST: The panels shall be joined to each other directly with 180O joinery or with the help of post to form different layouts. The types available are 90° 2 way, 3 way & 4 way, 120° 2 way, 3way & fin post 2way, 3way & 4way. The panel joinery post shall be made up of aluminium extrusion having material AL-96063-T6. It shall have average wall thickness of 1.2mm. It shall be coated with 50 to 60 micron thickness of epoxy powder coating. These joineries will be covered with die cast caps of powder coated aluminium alloy ADC 12. All the caps shall be press fitted on the respective extrusions. WORKTOP: Work top shall be made of 25mm thick prelaminated particle board interior grade (As per IS: 12823). Bottom shall have a backing laminate of minimum 0.6mm thickness. All the edges of work surface shall be provided with machine pressed 2 mm thick PVC Edge band glued with hotmelt EVA glue. Work top shall be mounted onto the partition panels for work stations by means of cantilever brackets made from 2.0 mm thick CRCA grade D steel as per IS:513-1994 duly pretreated and powder coated. The work surface shall be provided with circular (grommet) cut out of Dia.65mm as per the requirement, for passing of wires. These cut outs shall be provided with ABS covers. The Penta Return work surface shall be supported by the stiffener. The stiffener shall be fabricated from 2mm thick CRCA steel (IS: 513), plates of 5 mm & 3 mm thick HR steel (IS: 2062) & ERW steel tube of size 50X30X1.5 mm welded together. This stiffener shall connect to panel on one side and to Double Sided penta return leg on the other side. Work surface bracket shall be mounted on to the Horizontal extrusion. Work surface bracket shall be made from 2.0 mm thick CRCA grade D steel as per IS: 513-19. Ribs shall be provided in the bracket for strengthening purpose. All the work surface are mounted on the work surface brackets. Holder bracket shall be made from 2.0 mm thick CRCA grade D steel as per IS: 513-19. It shall slid in between end trim & vertical extrusion, & mounted on work surface with the help of pop rivet. Seating arrangement includes metal key board tray, CPU trolly and Nova free standing pedestal with central locking and flat metal front of size 390W x 435D x 646HT, 3dr=2box+1file. Approved Make: godrej wipro and equivalent | item266 | 28 | Number |
| 291 | 291 | Office Desk(workstation) Furniture & Fixtures\nProviding & Supplying BIFMA certified godrej wipro and equivalent Wish Penta workstation of size 1200W1 x 600D with spine finn combination. Panel thickness-52.4mm on one side AND 22.4mm. Panel thickness-52.4mm. Uprights and horizontals shall be made of aluminum extrusion having material AL96063-T6 & have average wall thickness of 1.2 mm & powder coated with epoxy-polyester powder. Fabricated bottom frame for 52.4mm shall comprise of L- Channels made of 2mm thick CRCA steel (IS:513), formed plates of 3mm thick HR steel (IS:2062) & ERW steel tube of size 35x15x1.6mm in oval cross section (IS:7138) welded together. This shall be coated with average 50 to 60 micron thickness of epoxy powder coating. This shall be bolted to the uprights with M6 screws. A block for 52.4mm panel’s thickness shall comprise of 38mm thick paper honeycomb with 3mm MDF on each sides and 0.6mm decorative laminate or fabric on both sides. Particle board framing shall be used on outer boundary of these blocks as well as intermediately at certain locations forming conduit for passing cables. These blocks (2nos.) will be located in the middle bands of the panels. The panel legs used for supporting panels. The height of a panel leg shall be 126mm. Panel legs shall be fabricated by CO2 welding MS Tube of section 38 mm x 25 mm (IS: 7138 ERW Tube) with the base plate of the MS plate of 35x22x5mm (IS: 2062, 5 mm HR) over which an M8 Leveler shall be fitted, which allows for adjustment of the height by 50mm. It will be coated with min. 45 micron thickness of epoxy powder coating. The single side legs shall be used for supporting panels & work surface on one side only. Single side legs shall be fabricated by CO2 welding MS Tube of section 38 mm x 25 mm (IS: 7138 ERW Tube) with the base plate of the MS plate of 35x22x5mm (IS: 2062, 5 mm HR) over which an M8 Leveler shall be fitted, which shall allow for adjustment of the height by 50mm. this shall be coated with min. 45 micron thickness of epoxy powder coating. Gable end panel shall be made of 18mm thick both side Pre laminated particle board of interior grade of approved shade conforming to IS: 12823. All the edges of panel shall be provided with machine pressed 2 mm thick PVC lipping glued with hot melt EVA glue. Cable duct shall be made from 0.8 mm thick M.S. CRCA Grade D as per IS: 513 - 1994. It is constructed with two parts, one is body & another is cover. It holds the cables & gives aesthetic appearance by covering all cables entry, which are moving upward to the panels. Size of Cable duct is 107mm W X 154 mm H X 21 mm D. TOP TILES: These tiles shall be slid in to the panels from top before fixing the top horizontal. These tiles shall be supported from top & bottom side with clips made from PP co polymer fitted in horizontal extrusion. Fabric magnetic tiles shall be fabric upholstered metal tiles in 0.6 mm thick G.I. Grade O as per IS: 277. The fabrics shall be upholstered with adhesives. Fabric tackable tiles shall be upholstered metal tiles in 0.6mm thick G.I. grade O as per IS: 277, with P.E. foam in the tile for tackablity. The fabric shall be upholstered with adhesives. White board tiles shall be made of 8.0 mm thick particle board conforming to IS: 12823 laminated with 0.6mm thick white glossy high pressure laminate on outer side & 0.6mm backing laminate on inner surface and will be having all its edges with minimum 0.5 mm thick PVC edging. BOTTOM TILES: All bottom tiles shall be press fitted on to the assembly frame of the panel with the help of snap on clips made of nylon-66 and support clips made from PP polymer. Plain Metal tiles shall be powder coated metal tiles in 0.8 mm thick M.S. CRCA Grade D as per IS: 513. ALUMINUM EXTRUSIONS: The top trims and end trims for 52.4 mm & 22.8 mm shall be made from aluminum extrusion having material AL96063-T6. All kinds of extrusions for 52.4 mm and 22.8 mm shall have average wall thickness of 1.2 mm & having finish of powder coating. Top trim in 52.4mm thick panel shall be press fitted on the horizontal extrusion & in 22.8mm thick panel it shall be slide fitted with the help of top trim connector made from PP copolymer 3530 grade. End trim for 52.4mm thick panel shall be slide fitted with the help of end trim connector made from 2.0mm thick M.S. CRCA Grade D as per IS: 513. End trim for 22.8 mm thick panel shall slide with the help of end trim connector made from nylon-66. \nSTABILITY POST: End stability post shall be fitted at the end of the free panel, to avoid movement of freestanding panels. The post shall be made in two parts. 1. The MS post which shall be grouted to the floor with Hilti make anchor bolts. 2. A cover extrusion of aluminium alloy shall cover the grouted MS stability bracket. The top end of the extrusion shall be covered with a powder coated aluminum cap. PANEL JOINERY POST: The panels shall be joined to each other directly with 180O joinery or with the help of post to form different layouts. The types available are 90° 2 way, 3 way & 4 way, 120° 2 way, 3way & fin post 2way, 3way & 4way. The panel joinery post shall be made up of aluminium extrusion having material AL-96063-T6. It shall have average wall thickness of 1.2mm. It shall be coated with 50 to 60 micron thickness of epoxy powder coating. These joineries will be covered with die cast caps of powder coated aluminium alloy ADC 12. All the caps shall be press fitted on the respective extrusions. WORKTOP: Work top shall be made of 25mm thick prelaminated particle board interior grade (As per IS: 12823). Bottom shall have a backing laminate of minimum 0.6mm thickness. All the edges of work surface shall be provided with machine pressed 2 mm thick PVC Edge band glued with hotmelt EVA glue. Work top shall be mounted onto the partition panels for work stations by means of cantilever brackets made from 2.0 mm thick CRCA grade D steel as per IS:513-1994 duly pretreated and powder coated. The work surface shall be provided with circular (grommet) cut out of Dia.65mm as per the requirement, for passing of wires. These cut outs shall be provided with ABS covers. The Penta Return work surface shall be supported by the stiffener. The stiffener shall be fabricated from 2mm thick CRCA steel (IS: 513), plates of 5 mm & 3 mm thick HR steel (IS: 2062) & ERW steel tube of size 50X30X1.5 mm welded together. This stiffener shall connect to panel on one side and to Double Sided penta return leg on the other side. Work surface bracket shall be mounted on to the Horizontal extrusion. Work surface bracket shall be made from 2.0 mm thick CRCA grade D steel as per IS: 513-19. Ribs shall be provided in the bracket for strengthening purpose. All the work surface are mounted on the work surface brackets. Holder bracket shall be made from 2.0 mm thick CRCA grade D steel as per IS: 513-19. It shall slid in between end trim & vertical extrusion, & mounted on work surface with the help of pop rivet. . Approved Make: godrej wipro and equivalent | item267 | 22 | Number |
| 292 | 292 | Ergonomic chairs for C&C \nOXBO MB-seat assembly: the seat assembly should be made up of 1.2 ±0.1cm. thick hot-pressed plywood , upholstered with fabric upholstery covers and moulded polyurethane foam.\nseat size: 47.0 cm. (w) x 48.0 cm. (d)back assembly: the back asembly. should be made of powder coated (oft 40-60 microns)tubular frame of 0 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. ms erw tube designed with contoured lumbar support for extra comfort. the back should be upholstered using double layer spacer mesh fabric with high tenacity yarn.\nback size : 46.5 cm (w) x 60.5 cm (h)high resilience (hr) polyurethane foam: the hr polyurethane foam should be moulded with density =45+/-2 kg/m3 and hardness load 16 ± 2 kgf for 25% compression.armrests: the one-piece armrests should be injection moulded from black co-polymer polypropylene. Centre-tilt mechanism: the mechashould be m should be designed with the following features:\n• 360° revolving type.\n• 17° ±2° maximum tilt on pivot at centre \n• upright position locking. \n tilt tension adjustment. .pneumatic height adjustment: the pneumatic height adjustment has an adjustment stroke of 11.0 ±0.3cm.elescopic bellow assy: the bellow should be 3 piece telescopic type and injection moulded in black polypropylene.pedestal assembly: the pedestal should be injection moulded in black 33% glass-filled nylon66 and fitted with 5 nos. twin wheel castors. the pedestal should be 66.3 ±0.5cm. pitch-center dia. (76.3 ±1.0cm with castors.)twin wheel castors: the twin wheel castors should be injection moulded in black nylon.Overall Dimensions of Chair\nSeat Height - min 43.3 to max 54.3cm.Height - min 89.5 to max 100.5cm.Width & Depth of Chair as measured from pedestal - Width-76.3 cm and Depth-76.3 cm | item268 | 50 | Number |
| 293 | 293 | Chairs for Managers\nOXBO HB-seat assembly: the seat assembly should be made up of 1.2 ±0.1cm. thick hot-pressed\nplywood , upholstered with fabric upholstery covers and moulded polyurethane foam.seat size: 47.0 cm. (w) x 48.0 cm. (d)back assembly: the back asembly. should be made of powder coated (oft 40-60 microns)\ntubular frame of 0 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. ms erw tube designed with contoured lumbar support for extra comfort. the back should be upholstered using double layer spacer mesh fabric with high tenacity yarn.back size : 46.5 cm (w) x 70.5 cm (h)high resilience (hr) polyurethane foam: the hr polyurethane foam should be moulded with density =45+/-2 kg/m3 and hardness load 16 ± 2 kgf for 25% compression.armrests: the one-piece armrests should be injection moulded from black co-polymer polypropylene. centre-tilt mechanism: the mechashould be m should be designed with the following features:\n• 360° revolving type.\n• 17° ±2° maximum tilt on pivot at centre \n• upright position locking. \n tilt tension adjustment. .\npneumatic height adjustment: the pneumatic height adjustment has an adjustment stroke of 11.0 ±0.3cm.telescopic bellow assy: the bellow should be 3 piece telescopic type and injection moulded in black polypropylene.pedestal assembly: the pedestal should be injection moulded in black 33% glass-filled nylon66 and fitted with 5 nos. twin wheel castors. the pedestal should be 66.3 ±0.5cm. pitch-center dia. (76.3 ±1.0cm with castors.) twin wheel castors: the twin wheel castors should be injection moulded in black nylon.Overall Dimensions of Chair-Seat Height - min 43.3 to max 54.3cm.Height - min 99.5 to max 110.5cm.\nWidth & Depth of Chair as measured from pedestal - Width-76.3 cm and Depth-76.3 cm. | item269 | 2 | Number |
| 294 | 294 | Chairs for conference rooms, misc\nBEAT HB FABRIC W/O SEAT SLIDE-\"SEAT/BACK ASSEMBLY: The seat & back is made up of 1.2 ± 0.1cm thk. hot pressed plywood measured as per QA method described in OCP-QLTA-PL14-18 upholstered with knitted fabric , over moulded High Resilience Polyurethane foam.\n*HIGH BACK SIZE: 51.8 cm. (W) x 75.2 cm. (H) \n* SEAT SIZE : 49.0 cm. (W) x 51.4 cm. (D)\nHIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam is moulded with density = 55+/-2 kg/m³ and hardness 16 ± 2 kgf as per IS:7888 for 25% compression.\nARMRESTS: The adjustable armrest is designed with the following features: • Up-Down adjustment– 8 steps (8.0±0.5 cm range) • Height adjustable armrest structure which is powder coated & fitted with an armrest top. \n(A) FRONT PIVOT SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features.\n• 360° revolving type.\n • Single point control.\n • Front-pivot for tilt with feet resting on ground ensuring more comfort. \n• Tilt tension adjustment. \n• 4-position locking with anti-shock feature. \n• Seat/back tilting ratio of 1:2.\nBACK HEIGHT ADJUSTABILITY: Back can be adjusted in 5 positions by manually. Stroke of height adjustable spine is 7 cm. Back height adjustability is applicable for High back and Mid back chair.\nPNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 10.0 ± 0.3 cm.\nPEDESTAL ASSEMBLY WITH CASTORS: The pedestal is injection moulded in black 30% glass-filled Nylon and fitted with 5 nos. twin wheel castors. The pedestal pitch-centre dia is Ø66.1 ± 0.5 cm. (76.1 ± 1.0 cm. with castors).\nTWIN WHEEL CASTORS: The twin wheel castors are injection moulded in black Nylon.\nOPTION OF SLIDING SEAT MECHANISM: Seat can be slide horizontally as per user convenience. Stroke of seat slide is 5 cm. This option is available for revolving pedestal type of chair.\" | item270 | 28 | Number |
| 295 | 295 | War Room Conference Table (15 personnel)\nENCARTA-Encarta Conference Table size shall be seats ( 1) 675 Width mm x 600 D epth mm x 750 Height mm , seats (2) 1350 Width mm x 600 Depth mm x 750 Height mm . Top shall be 25 mm PLB thick With PVC beading all over . In Understructure legs shall be made from 18 mm thick PLT having curved profile plus Modesty shall be made from PLT (pre - laminated twin ) boards 18 mm thick in two shades . Wire manager shall be running along the width of desk fitted on the modesty panel from inside. | item271 | 1 | Number |
| 296 | 296 | Small Conference Table (10 personnel)\nENCARTA-Encarta Conference Table size shall be seats ( 1) 675 Width mm x 600 D epth mm x 750 Height mm , seats (2) 1350 Width mm x 600 Depth mm x 750 Height mm . Top shall be 25 mm PLB thick With PVC beading all over . In Understructure legs shall be made from 18 mm thick PLT having curved profile plus Modesty shall be made from PLT (pre - laminated twin ) boards 18 mm thick in two shades . Wire manager shall be running along the width of desk fitted on the modesty panel from inside. | item272 | 1 | Number |
| 297 | 297 | Sofa (1 seater)\nPREMIUM LOUNGE 1 SEATER-)side frame assembly: the side frame assembly should be fitted to the two ends of the connecting beam assembly to form the leg-cum-armrest assembly. it should be made of 0 3.81 ±0.03cm. x 0.2 ±0.016cm. thick cmx0.16cnn and black powder coated ( dft 40-60 microns ). the ends should be fitted with abs moulded end caps.\n)tie member: it should be the connecting beam assy. which holds the two side frames to each other. 2 nos. tie members should be used to connect the side frames. the tie-member should be of 0 3.81 ±0.03cm. x 0.2 ±0.016cm. thick cm x 0.16cm and black powder coated ( dft 40-60 microns ). the seat/back assemblies should be mounted on one of the tie-member which has 5.0 ±0.1cm x 5.0 ±0.1 cm x 0.5 ±0.1cm. thk -- 5.5 ±0.1cm long ms. std. angles welded to mount the seat and back.\nseatrest assembly:the seat rest assembly consshould be ts of a fabricated inner-frame assembly insitu-moulded high resilience (hr) polyurethane foam having density = 45 +1- 2 kg/m3 with hardness load 25 ± 2 kgf for 25% compression of the foam. the complete moulded seat rest assembly should be covered with a replaceable fabric upholstery cover\n*seat size: 52.0cm. (w) x 50.0cm. (d) x 6.0cm. (t)\n)backrest assembly:the backrest assembly should be flexing type and consshould be ts of a fabricated inner-frame assembly insitu-moulded with high resilience (hr) polyurethane foam having density = 45 +1- 2 kg/m3 with hardness load 14 ± 2 kgf for 25% compression of the foam. the complete moulded backrest assembly should be covered with a replaceable fabric upholstery cover.\n*back size: 52.0cm. (w) x 59.0cm. (h) x 6.0cm. (t)\n)adj. glides: the adj. glide should be injection moulded in black nylon & fitted to the front end of side frame assembly along with abs moulded adj. glide base to take cshould be or unleveled floor surface.Overall Dimensions of Chair\nSeat Height - 43.5 cm.Height - 78.5cm.Width & Depth of Chair as - Width-60.5cm and Depth-70.0 cm. | item273 | 2 | Number |
| 298 | 298 | Sofa (2 seater)\nPREMIUM LOUNGE 2 SEATER-)side frame assembly: the side frame assembly should be fitted to the two ends of the connecting beam assembly to form the leg-cum-armrest assembly. it should be made of 0 3.81 ±0.03cm. x 0.2 ±0.016cm. thick cmx0.16cnn and black powder coated ( dft 40-60 microns ). the ends should be fitted with abs moulded end caps.\n)tie member: it should be the connecting beam assy. which holds the two side frames to each other. 2 nos. tie members should be used to connect the side frames. the tie-member should be of 0 3.81 ±0.03cm. x 0.2 ±0.016cm. thick cm x 0.16cm and black powder coated ( dft 40-60 microns ). the seat/back assemblies should be mounted on one of the tie-member which has 5.0 ±0.1cm x 5.0 ±0.1 cm x 0.5 ±0.1cm. thk -- 5.5 ±0.1cm long ms. std. angles welded to mount the seat and back.\nseatrest assembly:the seat rest assembly consshould be ts of a fabricated inner-frame assembly insitu-moulded high resilience (hr) polyurethane foam having density = 45 +1- 2 kg/m3 with hardness load 25 ± 2 kgf for 25% compression of the foam. the complete moulded seat rest assembly should be covered with a replaceable fabric upholstery cover\n*seat size: 52.0cm. (w) x 50.0cm. (d) x 6.0cm. (t)\n)backrest assembly:the backrest assembly should be flexing type and consshould be ts of a fabricated inner-frame assembly insitu-moulded with high resilience (hr) polyurethane foam having density = 45 +1- 2 kg/m3 with hardness load 14 ± 2 kgf for 25% compression of the foam. the complete moulded backrest assembly should be covered with a replaceable fabric upholstery cover.\n*back size: 52.0cm. (w) x 59.0cm. (h) x 6.0cm. (t)\n)adj. glides: the adj. glide should be injection moulded in black nylon & fitted to the front end of side frame assembly along with abs moulded adj. glide base to take cshould be or unleveled floor surface.Overall Dimensions of Chair\nSeat Height - 43.5 cm.Height - 78.5cm.Width & Depth of Chair as - Width-113.0cm and Depth-70.0 cm. | item274 | 2 | Number |
| 299 | 299 | Sofa (3 seater)\nPREMIUM LOUNGE 3 SEATER-)side frame assembly: the side frame assembly should be fitted to the two ends of the connecting beam assembly to form the leg-cum-armrest assembly. it should be made of 0 3.81 ±0.03cm. x 0.2 ±0.016cm. thick cmx0.16cnn and black powder coated ( dft 40-60 microns ). the ends should be fitted with abs moulded end caps.\n)tie member: it should be the connecting beam assy. which holds the two side frames to each other. 2 nos. tie members should be used to connect the side frames. the tie-member should be of 0 3.81 ±0.03cm. x 0.2 ±0.016cm. thick cm x 0.16cm and black powder coated ( dft 40-60 microns ). the seat/back assemblies should be mounted on one of the tie-member which has 5.0 ±0.1cm x 5.0 ±0.1 cm x 0.5 ±0.1cm. thk -- 5.5 ±0.1cm long ms. std. angles welded to mount the seat and back.\nseatrest assembly:the seat rest assembly consshould be ts of a fabricated inner-frame assembly insitu-moulded high resilience (hr) polyurethane foam having density = 45 +1- 2 kg/m3 with hardness load 25 ± 2 kgf for 25% compression of the foam. the complete moulded seat rest assembly should be covered with a replaceable fabric upholstery cover\n*seat size: 52.0cm. (w) x 50.0cm. (d) x 6.0cm. (t)\n)backrest assembly:the backrest assembly should be flexing type and consshould be ts of a fabricated inner-frame assembly insitu-moulded with high resilience (hr) polyurethane foam having density = 45 +1- 2 kg/m3 with hardness load 14 ± 2 kgf for 25% compression of the foam. the complete moulded backrest assembly should be covered with a replaceable fabric upholstery cover.\n*back size: 52.0cm. (w) x 59.0cm. (h) x 6.0cm. (t)\n)adj. glides: the adj. glide should be injection moulded in black nylon & fitted to the front end of side frame assembly along with abs moulded adj. glide base to take cshould be or unleveled floor surface.Overall Dimensions of Chair\nSeat Height - 43.5 cm.Height - 78.5cm.Width & Depth of Chair as - Width-164.0cm and Depth-70.0 cm. | item275 | 4 | Number |
| 300 | 300 | Cupboards (5 feet high)\nSLIMLINE MINOR 2S-Model 4S & 2SH Locker Model ‘H’ 900mm(W)x507mm(D)x1950mm(H) (Height without leveler). Construction & Material-? Aesthetically appealing Slimline, completely knock down construction. ? Removable Skirting to cover integral legs. ? Legs fitted with screw type leveler ? Made from combination of CRCA 0.8 mm & 0.6 mm Thickness. Main Door ? Steel Hinged Door. Main Door Locking / handle: ? Handle & Base Aesthetically appealing, Ergonomic, flush with door made from Zinc alloy. ? 3 way 90 Degree Removable key type Cam lock & locking mechanism. Locker Door & it’s locking / handle for Model ‘H’ .? Fixed Half locker on RH side ? Hinged Door ? 2 way Cam lock with Knob type handle Shelving: • Model 4S • Height wise Adjustable Shelf Mounting • 4 Nos. Of Full Adj.Shelves • Model 2SH • Height wise Adjustable Shelf Mounting • 2 Nos. Of Full Adj.Shelves • Locker Model ‘H’ – • Top fixed full shelf • Adjustable Half Shelves – 1 no. on RH & 2 nos. on LH side of Vertical Partition. Hanging Rod ? Model 2SH ? 1 no. Full length Hanging rod below top shelf mounted on Snap-on type plastic brackets. Locker Model ‘H’ ? 2 nos. half length Hanging rods – one on Left half of partition below top shelf & another on Right half below locker – both mounted on Snap-on type plastic brackets 9. Finish: ? Epoxy Powder coated to the thickness of 50 microns (+-10). | item276 | 2 | Number |
| 301 | 301 | Cupboards (6.5 feet high)\nSLIMLINE 4S-Model 4S & 2SH Locker Model ‘H’ 900mm(W)x507mm(D)x1950mm(H) (Height without leveler). Construction & Material-? Aesthetically appealing Slimline, completely knock down construction. ? Removable Skirting to cover integral legs. ? Legs fitted with screw type leveler ? Made from combination of CRCA 0.8 mm & 0.6 mm Thickness. Main Door ? Steel Hinged Door. Main Door Locking / handle: ? Handle & Base Aesthetically appealing, Ergonomic, flush with door made from Zinc alloy. ? 3 way 90 Degree Removable key type Cam lock & locking mechanism. Locker Door & it’s locking / handle for Model ‘H’ .? Fixed Half locker on RH side ? Hinged Door ? 2 way Cam lock with Knob type handle Shelving: • Model 4S • Height wise Adjustable Shelf Mounting • 4 Nos. Of Full Adj.Shelves • Model 2SH • Height wise Adjustable Shelf Mounting • 2 Nos. Of Full Adj.Shelves • Locker Model ‘H’ – • Top fixed full shelf • Adjustable Half Shelves – 1 no. on RH & 2 nos. on LH side of Vertical Partition. Hanging Rod ? Model 2SH ? 1 no. Full length Hanging rod below top shelf mounted on Snap-on type plastic brackets. Locker Model ‘H’ ? 2 nos. half length Hanging rods – one on Left half of partition below top shelf & another on Right half below locker – both mounted on Snap-on type plastic brackets 9. Finish: ? Epoxy Powder coated to the thickness of 50 microns (+-10). | item277 | 2 | Number |
| 302 | 302 | Center table\nProviding and supplying godrej wipro and equivalent Pisa CENTER Table. Width of table= 112.0 cm, Depth=60.0 cm, height=35.1 cm.It should be 12 ±0.3 mm thick black tinted Toughened glass UV glued with bushes made in SS 202 grade for fixing with understructure. It should be a welded Assembly made in SS202 grade having Dia. 12±0.04 as per should be :1762. OEM should be Green Guard and BIFMA Certified | item278 | 1 | Number |
| 303 | 303 | Side Table\nProviding and supplying godrej wipro and equivalent Pisa Side Table. Width of table= 60.0 cm, Depth=60.0 cm, height=35.1 cm.It should be 12 ±0.3 mm thick black tinted Toughened glass UV glued with bushes made in SS 202 grade for fixing with understructure. It should be a welded Assembly made in SS202 grade having Dia. 12±0.04 as per should be :1762. OEM should be Green Guard and BIFMA Certified | item279 | 6 | Number |
| 304 | 304 | Cupboard (Side)\nSLIMLINE 4S-Model 4S & 2SH Locker Model ‘H’ 900mm(W)x507mm(D)x1950mm(H) (Height without leveler). Construction & Material-? Aesthetically appealing Slimline, completely knock down construction. ? Removable Skirting to cover integral legs. ? Legs fitted with screw type leveler ? Made from combination of CRCA 0.8 mm & 0.6 mm Thickness. Main Door ? Steel Hinged Door. Main Door Locking / handle: ? Handle & Base Aesthetically appealing, Ergonomic, flush with door made from Zinc alloy. ? 3 way 90 Degree Removable key type Cam lock & locking mechanism. Locker Door & it’s locking / handle for Model ‘H’ .? Fixed Half locker on RH side ? Hinged Door ? 2 way Cam lock with Knob type handle Shelving: • Model 4S • Height wise Adjustable Shelf Mounting • 4 Nos. Of Full Adj.Shelves • Model 2SH • Height wise Adjustable Shelf Mounting • 2 Nos. Of Full Adj.Shelves • Locker Model ‘H’ – • Top fixed full shelf • Adjustable Half Shelves – 1 no. on RH & 2 nos. on LH side of Vertical Partition. Hanging Rod ? Model 2SH ? 1 no. Full length Hanging rod below top shelf mounted on Snap-on type plastic brackets. Locker Model ‘H’ ? 2 nos. half length Hanging rods – one on Left half of partition below top shelf & another on Right half below locker – both mounted on Snap-on type plastic brackets 9. Finish: ? Epoxy Powder coated to the thickness of 50 microns (+-10). | item280 | 10 | Number |
| 305 | 305 | Reception Desk\nProviding and supplying godrej wipro and equivalent First Impression Clean matt PU finish 18mm thick\nInside radius 700.0\nmm\nOutside radius – 1350.0 mm\nDepth – 650 mm Rubberized cork – 18mm thick\nGlass Frosted Glass 10mm thick Diamond cut\nfinishing on edges\nInside Radius – 1202.5mm\nOutside radius – 1402.5mm\nDepth – 200mm\n*Note: Angle sustained within arc surface is\n60 deg.\nUnderstr\nucture\nModesty Panel MS Perforated sheet\nBelow Worksurface : 0.8 mm (thick) x 665.0\nmm (height) x 1345.0 mm (flat length)\nAbove Worksurface : 0.8mm (Thick) x 260\nmm (height) x 1345.0 mm (flat length)\nLegs MS tube 1.6 mm thick\nDiameter 50.8 mm Height 604 mm | item281 | 1 | Number |
| 306 | 306 | CEO table 2350X2350X750\nCIGNUS 2350X2350X750-Primary Work -Surface\tMade of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.\nSecondary Work Surface-\tMade of 25mm thick MDF one side pre-aminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top.\nSoftclosing access flap with in-build power box are provided on work surface for wire management.\nModesty Panel-\tMade of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top\nUnder- structure-\tMade of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.\nIntegrated Pedestal\tMade of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Drawer fronts made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top\nPedstal construction is BOX-BOX-FILE type which Uses powder coated 400 MM long metal Panel Drawer Slides. Drawer extension is 325 MM.\nDrawers have a soft closing & anti slam mechanism. Handles are provided for ease of opening.\nPedestal is provided with lock for security. | item282 | 1 | Number |
| 307 | 307 | CEO CHAIR\nMARVEL HB-SEAT ASSEMBLY : The Cushioned seat should be made of Injection molded Plastic outer & inner. Plastic Inner should be upholstered with leatherette and moulded High Resilience (HR) Polyurethane foam of Density 45±2 kg/m3,and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. \n*Seat SIZE : 47.0 cm. (W) x 48.0 cm. (D) \n BACK ASSEMBLY: The Cushioned back should be made of PU Foam with insitu molded MS E.R.W Round Tube of size 1.9±0.03cm x 0.16 ±0.0128cm. It upholstered with Leatherette. \nHIGH BACK SIZE: 47.7 cm. (W) x 76.4 cm\n ARMRESTS : The armrest top should be moulded from polyurethane(PU) and mounted on to a drop lift adjustable type tubular armrest support made of 03.81±0.03 cm x 0.2±0.01 cm thk M.S. E.R.W tube having chrome plated finish.The armrest height adjustable up to 6.5±0.5cm in 5 steps. \n ACTIVE BIO-SYNCHRO MECHANISM : The adjustable tilting mechanism should be designed with the following features: \n• 360' revolving type. • Front-pivot for tilt with feet resting on ground and continuous lumbar support ensuring more comfort. • Tilt tension adjustment can be operated in seating position. • 5-position Tilt limiter giving option of variable tilt angle to the chair. • Seat/back tilting ratio of 1: 2 • The mechanism housing should be made up of HPDC Aluminium black powder coated. \n SEAT DEPTH ADJUSTMENT : Seat depth adjustment should be integrated in the seat through a sliding mechanism. Seat depth adjustment range should be of 6.0±0.5 cm. \nADJUSTABLE BACK SUPPORT: Back Frame should be connected to the Up/Dn mechanism housed in Plastic T spine. It can be adjusted in the range of 7.42±0.5 cm for the comfortable back support to suit individual need. \nPNEUMATIC HT. ADJUSTMENT: The pneumatic ht adjustment has an adjustment stroke of 10.0±0.3 cm. \n PEDESTAL ASSEMBLY: The pedestal should be High Pressure Die cast polished Aluminium and fitted with 5 nos. twin wheel castors. The pedestal should be 65.0 ± 0.5cm. pitch-center dia.(75.0 ± 1.0cm. With castors.) \n TWIN WHEEL CASTORS: The twin wheel castors should be injection moulded in black PP having 6.0± 0.1cm wheel Diameter. | item283 | 1 | Number |
| 308 | 308 | CEO VISITOR CHAIR\nMARVEL VISITOR-) SEAT ASSEMBLY : The Cushioned seat should be made of Injection molded Plastic outer & inner. Plastic Inner should be upholstered with leatherette and moulded High Resilience (HR) Polyurethane foam of Density 45±2 kg/m3,and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. \n*Seat SIZE : 47.0 cm. (W) x 48.0 cm. (D) \nBACK ASSEMBLY: The Cushioned back should be made of PU Foam with insitu molded MS E.R.W Round Tube of size 1.9±0.03cm x 0.16 ±0.0128cm. It upholstered with Leatherette. \nBACK SIZE: 47.7 cm. (W) x 60.1 cm. (D) \nVisitor TUBULAR FRAME: The tubular frame should be cantilever type and made of Ø2.54± 0.03 cm X 0.02 ± 0.016cm thick SS 202 tube. The back should be connected to frame through chrome plated high pressure die case connector piece | item284 | 7 | Number |
| 309 | 309 | ROUND TABLE\nProviding and supplying godrej wipro and equivalent Orion Round table 1050 dia.Worktop is made of 25mm THK PLT.\nKnocked down understructure made from 8mm HR plate with Levellers & a vertical support tube of dia 90 & 2mm Thickness. | item285 | 1 | Number |
| 310 | 310 | MANAGER TABLE 1800X2100X750\nFINNESSE 6030 + ERU 5216 + PEDESTAL-Finesse Table - 6030 size shall be 1800 Width mm x 900 Depth mm x 740 Height mm .Table top shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick backing laminate (bdl) .Flat edge Duly sealed with 2 mm thick PVC beading.The modesty shall be 18 mm thick plain particle board ( ) PPB Clad with 1.0 mm thick decorative laminate (DL) on both sides. Edge Sealed with 2 mm thick PVC beading.\nFinesse ERU -5216 LHS size shall be 1550 Width x 450 Depth x 705 Height.The top of Finesse ERU -5216 LHS shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick Backing Laminate ( BDL).Flat Edge duly sealed with 2 mm thick PVC beading. The Modesty shall be 18 mm thick plain particle board (PPB) Clad with 1.0 mm thick Decorative Laminate (DL) on both sides. Edge sealed with 2 mm thick PVC Beading.\nOverall Dimensions of Free Standing Ped With Castors For Finnesse Table shall be 390mm(W)x440mm(D)x646mm(H). The construction & Material used shall be welded assembled , 0.8 mm thick CRCA for body shell , drawer front & tray , front side stiffener ,rear aide stiffener and 1.2 mm thick CRCA Top stiffener & Bottom stoffener . The drawer fronts shall be metal front straight edge . Locking shall be 10 lever cam lock & Central RH locking with actuator & lock channel mechanism for box-box-file Pedestal . The top panel shall be metal straight edge top . Castor should be swiveling non - lockable castors mounted below the body shell for free standing full height mobile pedestal and M8 Leveling stud for free standing pedestal . The anti-tipping mechanism shall have fifth roller arrangement mounted below file drawer to avoid toppling of unit when file drawer is pulled out . Partition in drawer shall be 1 no. Partition in box drawers with lock mounted . Plastic pencil tray shall be optional accessory . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Application shall be suitable for pushing below work surface which has got a clear height of 725 mm from below . For drawer pulling side wise tapered recess provided in shell behind drawer fronts . | item286 | 1 | Number |
| 311 | 311 | ASST MANAGER TABLE 1650X1950X750\nFINNESSE 5630 + ERU 5216 + PEDESTAL-Finesse Table - 5630 size shall be 1650 Width mm x 900 Depth mm x 740 Height mm .Table top shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick backing laminate (bdl) .Flat edge Duly sealed with 2 mm thick PVC beading.The modesty shall be 18 mm thick plain particle board ( ) PPB Clad with 1.0 mm thick decorative laminate (DL) on both sides. Edge Sealed with 2 mm thick PVC beading.\nFinesse ERU -5216 LHS size shall be 1550 Width x 450 Depth x 705 Height.The top of Finesse ERU -5216 LHS shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick Backing Laminate ( BDL).Flat Edge duly sealed with 2 mm thick PVC beading. The Modesty shall be 18 mm thick plain particle board (PPB) Clad with 1.0 mm thick Decorative Laminate (DL) on both sides. Edge sealed with 2 mm thick PVC Beading.\nOverall Dimensions of Free Standing Ped With Castors For Finnesse Table shall be 390mm(W)x440mm(D)x646mm(H). The construction & Material used shall be welded assembled , 0.8 mm thick CRCA for body shell , drawer front & tray , front side stiffener ,rear aide stiffener and 1.2 mm thick CRCA Top stiffener & Bottom stoffener . The drawer fronts shall be metal front straight edge . Locking shall be 10 lever cam lock & Central RH locking with actuator & lock channel mechanism for box-box-file Pedestal . The top panel shall be metal straight edge top . Castor should be swiveling non - lockable castors mounted below the body shell for free standing full height mobile pedestal and M8 Leveling stud for free standing pedestal . The anti-tipping mechanism shall have fifth roller arrangement mounted below file drawer to avoid toppling of unit when file drawer is pulled out . Partition in drawer shall be 1 no. Partition in box drawers with lock mounted . Plastic pencil tray shall be optional accessory . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Application shall be suitable for pushing below work surface which has got a clear height of 725 mm from below . For drawer pulling side wise tapered recess provided in shell behind drawer fronts . | item287 | 1 | Number |
| 312 | 312 | ASST MANAGER TABLE 1650X1950X750\nproviding and supplying godrej wipro and equivalent PLU 4 door 380mm(W) x 450mm(D) x 1830mm(H)\nDMX Drg.-PL13-A4-33797, R1 – 4 Sheets (Cam\nLock)\nDMX Drg.-PL13-A4-36467, R1 – 4 Sheets (Hasp)The add-on units can be stacked width wise to form\nbank of lockers having common side panel.10 Lever cam lock with lock lever\n§ Option of hasp arrangement\n5. Material: CRCA 0.6mm Thickness\n6. Construction: Rigid knockdown construction.\n7. Shelf Uniformly Distributed Load Capacity per each shelf\nlevel is 35 Kg maximum.\n8. Hat Shelf Only for 1 Door Model at the top\n9. Hanging Rod · For 1 Door – Below Hat Shelf\n· For 2 Door – 1 Hanging rod in both compartment\n10. Finish: Epoxy Polyester Powder coated to the thickness of 50\nmicrons (+/-10).\n11. Handle / Label holder · Aesthetically appealing Snap fit ABS plastic\nhandle.\n· Plastic label holder for identification\n12. Ventilation Attractive punched pattern for ventilation\n13. Accessories (Optional) Stand for 1 wide, 2 wide and 3 wide – 125 mm High\n(add to unit height) inclusive of Leveler | item288 | 10 | Number |
| 313 | 313 | OPTIMIZER\nSD 2 BAY - 1NOS LD 2 BAY - 1NOS TD 2 BAY - 4 CHANNELS - 9 FT 2NOS Proviiding and supplying godrej wipro and equivalent Compactors : Supplying, fabricating and installing in position compactors of godrej wipro and equivalent make metal optimizers comprising of 3types of units (3bay) set on channels as follows:\nThe Construction of each unit shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS : 513 . Each body shall have a main unit plus add on units (1,2,3,4,5) . Finish shall be Epoxy polyester powder coated thickness of 40 microns. Shelf construction shall be made from CRCA steel 0.8 mm thick IS :513 .Uniformly distributed load capacity of 80 Kg. Undercarriage shall have construction in welded frame made of HR sheet 3.15 mm thick conforming to IS : 10748 . Finish shall be epoxy polyester powder coat of approved color & shade with a dry film thickness of minimum 40 microns . The Movements shall be Drive Type configuration : D2 & D3unit movement to be mechancial through a PU Drive Wheel and Sprocket -Chain-Tensioner arrangement mounted rigidly onto body size. In D3 each undercarriage to be movable with 2 rollers on the shaft for driving, 2 antifriction ball bearing for rolling and 4 antifriction ball bearing for guiding between rail. Centralized locking arrangement to be provided with approved Fittings, locking stiffener to be mounted onto back of single last unit so that it gets locked on channels when all the units are brought together . Recess handle lock arrangement not occupying more than 90.0mm space to be provided, lock to be of approved make & placed at suitable height . If the last unit is twin movable, hinged doors to be provided to the end bodies, in this case locking stiffener is mounted onto drive unit cover ; and with tile fascia option, mounted in the recess of vertical trim. Each Drive Type units shall have Locking Knob which will rotate to unlock for movement and placed near the drive wheel for manual locking of individual units when a person is using those units. End stoppers to be provided to prevent derailment. Door locking to be with hinged doors of recessed die cast handle cum lock giving 3 way locking through a lever & shooting bolts. Guide channels shall consist of 'J' section 2 mm thick & 25 mm square bright bar - both connected by screws . Prior to the embedding of the guide channels with the help of raul plug & screw , the ground has to be in proper leveled condition. Easteners shall be galvanized/ blackodized/Zn plated .The label holder shall be made from 2 mm thick clear transparent acrylic sheet . Also total no. of loading levels per understructure shall be 15 for LD3, 15 for SD3 and 30 forTD3. Fascia(tiling) 3 tile pattern fascia option on drive side panel plus 3 tile pattern fascia on non-drive side panel plus 3 tile pattern fascia option on back panel of single last plus 3 tile pattern fascia option on back panel of single static . The tiles to be held together by stiffeners & fasteners in 2 vertical metal trims., all complete. (Shop drawings to be submitted for Approval) . | item289 | 1 | Number |
| 314 | 314 | REST ROOM BED\nProviding and supplying godrej wipro and equivalent EQ bed with ply arrangement with headboard.Overall Size: Width - 2050.0 mm.Depth - 973.0 mm.Height - 720.0 mm\nMaterial :Headboard panels are made of 18 mm thick Prelaminated Particle Board.All the exposed edges are edge banded with 2 mm thick PVC edge banding.Bed leg frame structure consist of metal frames made of M.S. 50 x25 mm box section in 1.2 thickness Internal Pipes made of 19 x 19 mm box section in 0.9 mm thickness.Headboard pipes are made of 25 x 25 mm box section in 0.9 mm thickness.Mattress holding bkt is made of 0.6 mm CRCA SHEET. Note that Ply has to be arranged by contractor/end user. | item290 | 2 | Number |
| 315 | 315 | REST ROOM MATRESS\nProviding and suplying godrej wipro and equivalent Anand Milan Mat 78 36 4 Thickness: 10 cm\nWith a breathable coir base, PU foam and a correct combination of foam & coir, it has everything one needs for a good sleep | item291 | 2 | Number |
| 316 | 316 | Storage (Under workstation)\nNOVA PEDETAL 390X435X646 | item292 | 58 | Number |
| 317 | 317 | Soft Board:\nProviding and fixing Fabric wrapped soft board panels 12mm thick of size and profile as per detail with 6mm grooves made at the junction of soft board and partition and finished with Aluminium Hat sections. Soft board to be fixed on a backing of 12mm exterior grade MDF with PVC grippers at the edges. The rate should include cladding the panels in approved fabric (basic price Rs. 300/Rmt), 4mm thick foam infill as per approved specification. Note the fabric shall be stretched uniformly along the direction of weave and shall be wrinkle free. \nSize of 1500x1200mm | item293 | 2 | EACH |
| 318 | 318 | White Board:\nProviding and fixing 1mm thick White writing laminate on 12mm thick exterior grade MDF with grooves at the junction of writing laminate and partition as shown in the drawings. Cost to be inclusive of Aluminium beading at all edges of the MDF on which the laminate is stuck. The cost to include supplying and installing approved pen & duster holder with necessary supports, hardware, etc. complete. Approved makes: White Mark or Alko Sign or Fixograph\nSize of 1500x1200mm | item294 | 2 | EACH |
| 319 | 319 | Kitchen / Pantry equipments\nSamsung,LG, and simlar 253 L Frost Free Double Door 4 Star Refrigerator-\nThis 253 L refrigerator offers Stabiliser-free Operation to ensure optimal operation within a range of 100 - 300 volts. It also ensures that you don’t need an external stabiliser and protects the appliance from voltage fluctuations. It comes with a Door Alarm that alerts you when the door hasn’t been properly closed. This helps prevent the loss of cool air and wastage of electricity. | item295 | 1 | Number |
| 320 | 320 | Kitchen / Pantry equipments\nSamsung,LG and Simlar 28 L Convection Microwave Oven-\nIndian cooking has a style of its own. This 28 L microwave oven from Samsung,LG and simlar understands that and is designed to mix spices, make tadka seasoning, and papads with ease. | item296 | 1 | Number |
| 321 | 321 | Kitchen / Pantry equipments\nCommercial Type Tea Coffee and Soup Vending Machine- | item297 | 1 | Number |
| 322 | 322 | Kitchen / Pantry equipments\ncommercial type Hot N Ambient N Cold is the all-season water purifier simple push of a button type machin. | item298 | 1 | Number |
| 323 | 323 | Any other item to meet the requirements of the RFP | item299 | 1 | Number |
| 324 | 1000 | Price Component For OPEX | |||
| 325 | 1001 | Comprehensive AMC for 1st Year of Operation and Maintenance - Command and Control Centre | |||
| 326 | 1002 | Video Wall Solution- 55\" LED (Matrix of 4*3) | item300 | 12 | Number |
| 327 | 1003 | Video wall controller with cabling and other fixture and wall management software | item301 | 1 | Lot |
| 328 | 1004 | Operator Workstation (CCC and NOC) with 2 monitors (22\") with office productivity suite licenses | item302 | 28 | Number |
| 329 | 1005 | Operator Workstation (Helpdesk) with 1 monitor (22\") with office productivity suite licenses | item303 | 10 | Number |
| 330 | 1006 | Laptop for higher management with office productivity suite licenses | item304 | 2 | Number |
| 331 | 1007 | Network Colour Laser Printer (A3) | item305 | 1 | Number |
| 332 | 1008 | Network B/w Laser Printers (A4) | item306 | 2 | Number |
| 333 | 1009 | Network B/w Heavy Duty Laser Printers | item307 | 1 | Number |
| 334 | 1010 | Multi Function Printer (MFP) | item308 | 2 | Number |
| 335 | 1011 | IP Phone | item309 | 51 | Number |
| 336 | 1012 | Indoor Fixed Dome Cameras for internal surveillance | item310 | 25 | Number |
| 337 | 1013 | Wifi Access for CCC | item311 | 1 | Lot |
| 338 | 1014 | Networking Cost (Passive Components such as LAN/CAT 6 Cabling) | item312 | 1 | Lumpsum |
| 339 | 1015 | Electrical Cabling & Necessary Illumination Devices for CCC, War Room, Helpdesk room, NOC room, Manager(s) room etc. | item313 | 1 | Lumpsum |
| 340 | 1016 | IP PABX for CCC including all accesories | item314 | 1 | Lot |
| 341 | 1017 | Digital Set top box | item315 | 2 | Number |
| 342 | 1018 | Video Conferencing Unit | item316 | 1 | Number |
| 343 | 1019 | 55\" LED display to present critical information Display (War Room) | item317 | 1 | Number |
| 344 | 1020 | Microphone with respective accessories | item318 | 15 | Number |
| 345 | 1021 | Headphones | item319 | 10 | Number |
| 346 | 1022 | PRI Line (Pair) with all necessary accessories | item320 | 1 | Number |
| 347 | 1023 | SMS Gateway modem | item321 | 1 | Number |
| 348 | 1024 | Any other item | item322 | 1 | Number |
| 349 | 1025 | Comprehensive AMC for 1st Year of Operation and Maintenance - DC Hardware | |||
| 350 | 1026 | Core Router | item323 | 2 | Number |
| 351 | 1027 | Core Switch | item324 | 2 | Number |
| 352 | 1028 | L3 Switch | item325 | 1 | Lot |
| 353 | 1029 | L2 Switch | item326 | 1 | Lot |
| 354 | 1030 | Server load balancer | item327 | 2 | Number |
| 355 | 1031 | Networking Cost (Passive Components) | item328 | 1 | Lumpsum |
| 356 | 1032 | Internet Router | item329 | 2 | Number |
| 357 | 1033 | KVM Switch/Module | item330 | 1 | Number |
| 358 | 1034 | 42 U Racks for Networking | item331 | 2 | Number |
| 359 | 1035 | 42 U Racks for servers and storage | item332 | 8 | Number |
| 360 | 1036 | Online UPS with battery backup | item333 | 1 | Number |
| 361 | 1037 | Storage with 2 no. of SAN Switches & Complete mounting accessories | item334 | 1 | Lot |
| 362 | 1038 | Storage - Tape Drive & Library | item335 | 1 | Lot |
| 363 | 1039 | Blade Servers & Chassis | item336 | 1 | Lot |
| 364 | 1040 | Firewall (External) {1+1 in HA Mode} | item337 | 2 | Number |
| 365 | 1041 | Firewall (Internal) {1+1 in HA Mode} | item338 | 2 | Number |
| 366 | 1042 | Data Loss Protection (DLP) | item339 | 1 | Lot |
| 367 | 1043 | Anti - Advanced Persistent Threat (Anti-APT) | item340 | 1 | Lot |
| 368 | 1044 | Anti - Distributed Denial of Service (DDoS) | item341 | 1 | Lot |
| 369 | 1045 | Security Information and Event Management (SIEM) | item342 | 1 | Lot |
| 370 | 1046 | Network Access Control (NAC) including Patch Management | item343 | 1 | Lot |
| 371 | 1047 | IDAM Solution (1+1 in HA mode) | item344 | 1 | Lot |
| 372 | 1048 | Host Intrusion Prevention System (HIPS) | item345 | 1 | Lot |
| 373 | 1049 | Web Application Firewall (WAF) | item346 | 1 | Lot |
| 374 | 1050 | Any other Item | item347 | 1 | Number |
| 375 | 1051 | Comprehensive AMC for 1st Year of Operation and Maintenance - DC Applications and Software | |||
| 376 | 1052 | Enterprise Management System(including SLA Mgmt, Helpdesk Mgmt, Network Mgmt, BMS) | item348 | 1 | Lot |
| 377 | 1053 | Backup software | item349 | 1 | Lot |
| 378 | 1054 | Virtualization Software | item350 | 1 | Lot |
| 379 | 1055 | DRM (DC-DR Sync) Software | item351 | 1 | Lot |
| 380 | 1056 | Anti-virus (Software) for workstations | item352 | 40 | Number |
| 381 | 1057 | Anti-Virus for Server | item353 | 1 | Lot |
| 382 | 1058 | ICCC Software with Perpetual License and unlimited sensors | item354 | 1 | LS |
| 383 | 1059 | Call Centre Management (Software) | item355 | 1 | LS |
| 384 | 1060 | Video Management Software | item356 | 1 | Number |
| 385 | 1061 | Central Management Software for detetcting RLVD, No Helmet and Triple Riding | item357 | 1 | Lot |
| 386 | 1062 | Central Management Software for detecting Wrong way | item358 | 1 | Lot |
| 387 | 1063 | Central Management Software for detecting Speed violation | item359 | 1 | Lot |
| 388 | 1064 | Enterprise violations management system for fines and connectivity with vahan and sarathi for auto vehicle identification and fines registry | item360 | 1 | Lot |
| 389 | 1065 | Variable Messaging Display Software | item361 | 1 | Lot |
| 390 | 1066 | Centralized Software for Smart Street Lights (Including Mobile Apps) | item362 | 1 | Lot |
| 391 | 1067 | Smart Parking Software including Dashboarding, reporting & Analytic tools | item363 | 1 | Lot |
| 392 | 1068 | Smart Parking POS software | item364 | 1 | Lot |
| 393 | 1069 | GIS Platform License (server based) | item365 | 1 | Number |
| 394 | 1070 | GIS Platform - Desktop (Editing license) | item366 | 3 | Number |
| 395 | 1071 | ATCS Software Solution | item367 | 1 | Lot |
| 396 | 1072 | Software license for Database server | item368 | 1 | Lot |
| 397 | 1073 | Software license per servers | item369 | 1 | Lot |
| 398 | 1074 | Software license for web server | item370 | 1 | Lot |
| 399 | 1075 | Any other item | item371 | 1 | Number |
| 400 | 1076 | Comprehensive AMC for 1st Year of Operation and Maintenance - ERP , Mobile Application and Web-portal | |||
| 401 | 1077 | Software support cost for ERP application and licenses | item372 | 1 | Lot |
| 402 | 1078 | Software support cost for Web Portal & Mobile Application | item373 | 1 | Lot |
| 403 | 1079 | Any other Item | item374 | 1 | Number |
| 404 | 1080 | Comprehensive AMC for 1st Year of Operation and Maintenance - GIS | |||
| 405 | 1081 | GIS Application suite | item375 | 1 | Lot |
| 406 | 1082 | Any other item | item376 | 1 | Number |
| 407 | 1083 | Comprehensive AMC for 1st Year of Operation and Maintenance - Active and Passive components including junction box | |||
| 408 | 1084 | Access Switch L2 Industrial Grade with SFP and Patch Cord | item377 | 72 | Nos |
| 409 | 1085 | Fibre Patch cords 20 metres | item378 | 55 | Units |
| 410 | 1086 | Electricity Metres at Junction Boxes | item379 | 55 | Units |
| 411 | 1087 | Field Junction Box/Cabinets for all field components of project | item380 | 55 | Nos |
| 412 | 1088 | Online field UPS with Battery Bank for 2 hours | item381 | 55 | Nos |
| 413 | 1089 | HDPE Pipe - 50 mm | item382 | 1 | Lot |
| 414 | 1090 | HDPE Pipe - 90 mm | item383 | 1 | Lot |
| 415 | 1091 | DWC Pipe - 90 mm | item384 | 1 | Lot |
| 416 | 1092 | DWC Pipe - 120 mm | item385 | 1 | Lot |
| 417 | 1093 | Electrical Cable - 3 Core,2.5 Sqmm Unarmoured Cable | item386 | 1 | Lot |
| 418 | 1094 | Electrical Cable - 3 Core,2.5 Sqmm armoured Cable | item387 | 1 | Lot |
| 419 | 1095 | Electrical Cable - 7 Core,1.5 Sqmm Armoured Cable | item388 | 1 | Lot |
| 420 | 1096 | Electrical Cable - 14 Core,1.5 Sqmm Armoured Cable | item389 | 1 | Lot |
| 421 | 1097 | Any other Item | item390 | 1 | Number |
| 422 | 1098 | Comprehensive AMC for 1st Year of Operation and Maintenance - Traffic Enforcement and Surveillance | |||
| 423 | 1099 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 8 lanes (2 Lanes in each arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illuminator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item391 | 12 | Traffic Junction |
| 424 | 1100 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 3 arms & 6 lanes (2 lanes in each Arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item392 | 4 | Traffic Junction |
| 425 | 1101 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 6 lanes (2 Lanes in 2 Arms each and 1 lane in remaing 2 Arms each) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item393 | 1 | Traffic Junction |
| 426 | 1102 | Speed Detection System for covering 2 lanes in one direction with complete subcomponents including ANPR camera, wide angle evidence camera, IR illuminator, non intrusive speed sensor with cabling & mounting infrastructure as required | item394 | 20 | Location |
| 427 | 1103 | ANPR System for capturing number plates at 2 arms and 4 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item395 | 5 | Location |
| 428 | 1104 | ANPR System for capturing number plates at 2 arms and 6 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item396 | 6 | Location |
| 429 | 1105 | Wrong way detection System covering 1 arm and 1 lane at each Location with complete hardware including ANPR camera, cabling, accessories and mounting infrastructure as required | item397 | 8 | Location |
| 430 | 1106 | Traffic Surveillance PTZ Cameras System with Complete mounting accessories as required | item398 | 6 | Number |
| 431 | 1107 | Traffic Surveillance Overview/Fixed box Cameras System with required Hardware and Softwae including Local Processing Unit, cabling, accessories & mounting infrastructure as required | item399 | 122 | Number |
| 432 | 1108 | Poles for Cameras and Equipments | item400 | 42 | Number |
| 433 | 1109 | E-Challan Handheld Device including Software | item401 | 15 | Number |
| 434 | 1110 | Indoor Fixed Dome Cameras for internal surveillance | item402 | 420 | Number |
| 435 | 1111 | 2 Megapixel Full HD IR IP Vandal proof Bullet Camera with Varifocal Lens | item403 | 140 | Number |
| 436 | 1112 | 8 channel Network Video Recorder (NVR) | item404 | 70 | Number |
| 437 | 1113 | 32\" LED display | item405 | 70 | Number |
| 438 | 1114 | Video Channel License | item406 | 560 | Number |
| 439 | 1115 | 8 Port Managed PoE/PoE+ Network switch | item407 | 70 | Number |
| 440 | 1116 | SFP (1G) Short haul | item408 | 140 | Number |
| 441 | 1117 | Fibre Patch cords 2 metres | item409 | 140 | Units |
| 442 | 1118 | Networking (CAT6) cable | item410 | 1 | Lot |
| 443 | 1119 | Flexible Power cables 3 core, 1.5 sq. mm copper cable | item411 | 1 | Lot |
| 444 | 1120 | PVC Pipe 22 mm diameter | item412 | 1 | Lot |
| 445 | 1121 | UPS with 1 hour backup | item413 | 70 | Number |
| 446 | 1122 | 9U Rack | item414 | 70 | Number |
| 447 | 1123 | Any Other Item | item415 | 1 | Number |
| 448 | 1124 | Comprehensive AMC for 1st Year of Operation and Maintenance - Adaptive Traffic Control System | |||
| 449 | 1125 | ATCS Traffic Controller with all mounting accessaries | item416 | 17 | Number |
| 450 | 1126 | Countdown timer (CDT) with all mounting accessaries | item417 | 126 | Number |
| 451 | 1127 | Vehicle Detector Camera with all mounting accessaries | item418 | 63 | Number |
| 452 | 1128 | Cantilever poles | item419 | 63 | Number |
| 453 | 1129 | Standard poles for Traffic Signals | item420 | 97 | Number |
| 454 | 1130 | Traffic Light Aspects - Red | item421 | 189 | Number |
| 455 | 1131 | Traffic Light Aspects - Green (Green Straight, Green Right, Green Left) | item422 | 531 | Number |
| 456 | 1132 | Traffic Light Aspects - Amber | item423 | 189 | Number |
| 457 | 1133 | Pedestrian lamp heads - Stop & Walk Man | item424 | 126 | Number |
| 458 | 1134 | 3 Core,2.5 Sqmm Unarmoured Cable | item425 | 1 | Lot |
| 459 | 1135 | 3 Core, 2.5 Sqmm Armoured Cable | item426 | 1 | Lot |
| 460 | 1136 | 7 Core, 1.5 Sqmm Armoured Cable | item427 | 1 | Lot |
| 461 | 1137 | 14 Core, 1.5 Sqmm Armoured Cable | item428 | 1 | Lot |
| 462 | 1138 | Any other item | item429 | 1 | Number |
| 463 | 1139 | Comprehensive AMC for 1st Year of Operation and Maintenance - Variable Messaging Display and Environmental Sensors | |||
| 464 | 1140 | VMD (3 x 1.5m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item430 | 4 | Number |
| 465 | 1141 | VMD (8 x 3m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item431 | 7 | Number |
| 466 | 1142 | Environmental sensors including all cabling and mounting accessories | item432 | 2 | Number |
| 467 | 1143 | Any other Item | item433 | 1 | Number |
| 468 | 1144 | Comprehensive AMC for 1st Year of Operation and Maintenance - Smart Street Lights | |||
| 469 | 1145 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 6 LED Fixures with necessary communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure | item434 | 17 | Number |
| 470 | 1146 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 8 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item435 | 11 | Number |
| 471 | 1147 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 12 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item436 | 6 | Number |
| 472 | 1148 | Street light Controller & dimming driver for existing functional LED Street Lights 100W to 300W each on Single/ Double/ Triple poles with capability to handle/ control the min 10 Nos to Max 100 Nos of LED Street Light Poles per feeder panel commmununication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item437 | 104 | Number |
| 473 | 1149 | Any Other Item | item438 | 1 | Number |
| 474 | 1150 | Comprehensive AMC for 1st Year of Operation and Maintenance - Smart Parking | |||
| 475 | 1151 | Magenetic sensor - surface mount | item439 | 325 | Number |
| 476 | 1152 | Networking/Communication for magnetic sensors including all necessary cablings and accessories | item440 | 7 | Lot |
| 477 | 1153 | Handheld device with scanner and printer with 8 hrs battery backup at full load with networking capability to command centre or Mobile POS device | item441 | 15 | Number |
| 478 | 1154 | Any other Item | item442 | 1 | Number |
| 479 | 1155 | SMS Services for 1st Year of Operation and Maintenance | |||
| 480 | 1156 | SMS Services (10000 sms pack) per Year | item443 | 1 | Number |
| 481 | 1157 | Comprehensive AMC for 1st Year of Operation and Maintenance - Leased Line | |||
| 482 | 1158 | Internet Leased Line for ICCC of 100 Mbps | item444 | 2 | Number |
| 483 | 1159 | Leased Line connectivity between DC and DR of 100 Mbps | item445 | 2 | Number |
| 484 | 1160 | Leased Line bandwidth of 2 Mbps Link Between ICCC and end remote locations | item446 | 16 | Number |
| 485 | 1161 | Leased Line bandwidth of 5 Mbps Link Between ICCC and end remote locations | item447 | 3 | Number |
| 486 | 1162 | Leased Line bandwidth of 10 Mbps Link Between ICCC and end remote locations | item448 | 1 | Number |
| 487 | 1163 | Leased Line bandwidth of 20 Mbps Link Between ICCC and end remote locations | item449 | 24 | Number |
| 488 | 1164 | Leased Line bandwidth of 30 Mbps Link Between ICCC and end remote locations | item450 | 82 | Number |
| 489 | 1165 | Leased Line bandwidth of 40 Mbps Link Between ICCC and end remote locations | item451 | 1 | Number |
| 490 | 1166 | Leased Line bandwidth of 50 Mbps Link Between ICCC and end remote locations | item452 | 4 | Number |
| 491 | 1167 | Leased line to connect DC with checkpost locations 20 Mbps | item453 | 6 | Number |
| 492 | 1168 | DR Infra on cloud for 1st Year of Operation and Maintenance | |||
| 493 | 1169 | DR Infra on cloud - Server and Storage | item454 | 1 | Number |
| 494 | 1170 | Manpower for 1st Year of Operation and Maintenance | |||
| 495 | 1171 | Project Manager - Onsite | item455 | 1 | Number |
| 496 | 1172 | Technical Expert- Command & Control Center - Onsite | item456 | 1 | Number |
| 497 | 1173 | Technical Expert – Server and storage - Onsite | item457 | 1 | Number |
| 498 | 1174 | Technical Expert – Video Surveillance and IoT devices - Onsite | item458 | 1 | Number |
| 499 | 1175 | Technical Expert – Networking, EMS/NMS & Software Application - Onsite | item459 | 1 | Number |
| 500 | 1176 | Database Administrator - onsite | item460 | 1 | Number |
| 501 | 1177 | Cybersecurity Expert - Onsite | item461 | 1 | Number |
| 502 | 1178 | GIS Expert - Onsite | item462 | 1 | Number |
| 503 | 1179 | ERP Developer - Onsite | item463 | 1 | Number |
| 504 | 1180 | Data entry Operator - Onsite | item464 | 1 | Number |
| 505 | 1181 | CCC Supervisors (one per shift) - Onsite | item465 | 2 | Number |
| 506 | 1182 | Helpdesk Staff (2 per shift) - Onsite | item466 | 4 | Number |
| 507 | 1183 | Field Staff (2 per shift) - Onsite | item467 | 4 | Number |
| 508 | 1184 | Training for 1st Year of Operation and Maintenance | |||
| 509 | 1185 | Refresher Training | item468 | 6 | Batches |
| 510 | 1186 | Audit for 1st Year of Operation and Maintenance | |||
| 511 | 1187 | IT Audit | item469 | 1 | Lot |
| 512 | 1188 | Comprehensive AMC for 1st Year of Operation and Maintenance of Non-ICT components | |||
| 513 | 1189 | Operation and Maintenance of Electrical Including Diesel Cost for running of DG Set. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item470 | 1 | Lumpsum |
| 514 | 1190 | Operation and Maintenance of HVAC. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item471 | 1 | Lumpsum |
| 515 | 1191 | Operation and Maintenance of Fire Fighting. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item472 | 1 | Lumpsum |
| 516 | 1192 | Operation and Maintenance of Furniture. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item473 | 1 | Lumpsum |
| 517 | 1193 | Comprehensive AMC for 2nd Year of Operation and Maintenance - Command and Control Centre | |||
| 518 | 1194 | Video Wall Solution- 55\" LED (Matrix of 4*3) | item474 | 12 | Number |
| 519 | 1195 | Video wall controller with cabling and other fixture and wall management software | item475 | 1 | Lot |
| 520 | 1196 | Operator Workstation (CCC and NOC) with 2 monitors (22\") with office productivity suite licenses | item476 | 28 | Number |
| 521 | 1197 | Operator Workstation (Helpdesk) with 1 monitor (22\") with office productivity suite licenses | item477 | 10 | Number |
| 522 | 1198 | Laptop for higher management with office productivity suite licenses | item478 | 2 | Number |
| 523 | 1199 | Network Colour Laser Printer (A3) | item479 | 1 | Number |
| 524 | 1200 | Network B/w Laser Printers (A4) | item480 | 2 | Number |
| 525 | 1201 | Network B/w Heavy Duty Laser Printers | item481 | 1 | Number |
| 526 | 1202 | Multi Function Printer (MFP) | item482 | 2 | Number |
| 527 | 1203 | IP Phone | item483 | 51 | Number |
| 528 | 1204 | Indoor Fixed Dome Cameras for internal surveillance | item484 | 25 | Number |
| 529 | 1205 | Wifi Access for CCC | item485 | 1 | Lot |
| 530 | 1206 | Networking Cost (Passive Components such as LAN/CAT 6 Cabling) | item486 | 1 | Lumpsum |
| 531 | 1207 | Electrical Cabling & Necessary Illumination Devices for CCC, War Room, Helpdesk room, NOC room, Manager(s) room etc. | item487 | 1 | Lumpsum |
| 532 | 1208 | IP PABX for CCC including all accesories | item488 | 1 | Lot |
| 533 | 1209 | Digital Set top box | item489 | 2 | Number |
| 534 | 1210 | Video Conferencing Unit | item490 | 1 | Number |
| 535 | 1211 | 55\" LED display to present critical information Display (War Room) | item491 | 1 | Number |
| 536 | 1212 | Microphone with respective accessories | item492 | 15 | Number |
| 537 | 1213 | Headphones | item493 | 10 | Number |
| 538 | 1214 | PRI Line (Pair) with all necessary accessories | item494 | 1 | Number |
| 539 | 1215 | SMS Gateway modem | item495 | 1 | Number |
| 540 | 1216 | Any other item | item496 | 1 | Number |
| 541 | 1217 | Comprehensive AMC for 2nd Year of Operation and Maintenance - DC Hardware | |||
| 542 | 1218 | Core Router | item497 | 2 | Number |
| 543 | 1219 | Core Switch | item498 | 2 | Number |
| 544 | 1220 | L3 Switch | item499 | 1 | Lot |
| 545 | 1221 | L2 Switch | item500 | 1 | Lot |
| 546 | 1222 | Server load balancer | item501 | 2 | Number |
| 547 | 1223 | Networking Cost (Passive Components) | item502 | 1 | Lumpsum |
| 548 | 1224 | Internet Router | item503 | 2 | Number |
| 549 | 1225 | KVM Switch/Module | item504 | 1 | Number |
| 550 | 1226 | 42 U Racks for Networking | item505 | 2 | Number |
| 551 | 1227 | 42 U Racks for servers and storage | item506 | 8 | Number |
| 552 | 1228 | Online UPS with battery backup | item507 | 1 | Number |
| 553 | 1229 | Storage with 2 no. of SAN Switches & Complete mounting accessories | item508 | 1 | Lot |
| 554 | 1230 | Storage - Tape Drive & Library | item509 | 1 | Lot |
| 555 | 1231 | Blade Servers & Chassis | item510 | 1 | Lot |
| 556 | 1232 | Firewall (External) {1+1 in HA Mode} | item511 | 2 | Number |
| 557 | 1233 | Firewall (Internal) {1+1 in HA Mode} | item512 | 2 | Number |
| 558 | 1234 | Data Loss Protection (DLP) | item513 | 1 | Lot |
| 559 | 1235 | Anti - Advanced Persistent Threat (Anti-APT) | item514 | 1 | Lot |
| 560 | 1236 | Anti - Distributed Denial of Service (DDoS) | item515 | 1 | Lot |
| 561 | 1237 | Security Information and Event Management (SIEM) | item516 | 1 | Lot |
| 562 | 1238 | Network Access Control (NAC) including Patch Management | item517 | 1 | Lot |
| 563 | 1239 | IDAM Solution (1+1 in HA mode) | item518 | 1 | Lot |
| 564 | 1240 | Host Intrusion Prevention System (HIPS) | item519 | 1 | Lot |
| 565 | 1241 | Web Application Firewall (WAF) | item520 | 1 | Lot |
| 566 | 1242 | Any other Item | item521 | 1 | Number |
| 567 | 1243 | Comprehensive AMC for 2nd Year of Operation and Maintenance - DC Applications and Software | |||
| 568 | 1244 | Enterprise Management System(including SLA Mgmt, Helpdesk Mgmt, Network Mgmt, BMS) | item522 | 1 | Lot |
| 569 | 1245 | Backup software | item523 | 1 | Lot |
| 570 | 1246 | Virtualization Software | item524 | 1 | Lot |
| 571 | 1247 | DRM (DC-DR Sync) Software | item525 | 1 | Lot |
| 572 | 1248 | Anti-virus (Software) for workstations | item526 | 40 | Number |
| 573 | 1249 | Anti-Virus for Server | item527 | 1 | Lot |
| 574 | 1250 | ICCC Software with Perpetual License and unlimited sensors | item528 | 1 | LS |
| 575 | 1251 | Call Centre Management (Software) | item529 | 1 | LS |
| 576 | 1252 | Video Management Software | item530 | 1 | Number |
| 577 | 1253 | Central Management Software for detetcting RLVD, No Helmet and Triple Riding | item531 | 1 | Lot |
| 578 | 1254 | Central Management Software for detecting Wrong way | item532 | 1 | Lot |
| 579 | 1255 | Central Management Software for detecting Speed violation | item533 | 1 | Lot |
| 580 | 1256 | Enterprise violations management system for fines and connectivity with vahan and sarathi for auto vehicle identification and fines registry | item534 | 1 | Lot |
| 581 | 1257 | Variable Messaging Display Software | item535 | 1 | Lot |
| 582 | 1258 | Centralized Software for Smart Street Lights (Including Mobile Apps) | item536 | 1 | Lot |
| 583 | 1259 | Smart Parking Software including Dashboarding, reporting & Analytic tools | item537 | 1 | Lot |
| 584 | 1260 | Smart Parking POS software | item538 | 1 | Lot |
| 585 | 1261 | GIS Platform License (server based) | item539 | 1 | Number |
| 586 | 1262 | GIS Platform - Desktop (Editing license) | item540 | 3 | Number |
| 587 | 1263 | ATCS Software Solution | item541 | 1 | Lot |
| 588 | 1264 | Software license for Database server | item542 | 1 | Lot |
| 589 | 1265 | Software license per servers | item543 | 1 | Lot |
| 590 | 1266 | Software license for web server | item544 | 1 | Lot |
| 591 | 1267 | Any other item | item545 | 1 | Number |
| 592 | 1268 | Comprehensive AMC for 2nd Year of Operation and Maintenance - ERP , Mobile Application and Web-portal | |||
| 593 | 1269 | Software support cost for ERP application and licenses | item546 | 1 | Lot |
| 594 | 1270 | Software support cost for Web Portal & Mobile Application | item547 | 1 | Lot |
| 595 | 1271 | Any other Item | item548 | 1 | Number |
| 596 | 1272 | Comprehensive AMC for 2nd Year of Operation and Maintenance - GIS | |||
| 597 | 1273 | GIS Application suite | item549 | 1 | Lot |
| 598 | 1274 | Any other item | item550 | 1 | Number |
| 599 | 1275 | Comprehensive AMC for 2nd Year of Operation and Maintenance - Active and Passive components including junction box | |||
| 600 | 1276 | Access Switch L2 Industrial Grade with SFP and Patch Cord | item551 | 72 | Nos |
| 601 | 1277 | Fibre Patch cords 20 metres | item552 | 55 | Units |
| 602 | 1278 | Electricity Metres at Junction Boxes | item553 | 55 | Units |
| 603 | 1279 | Field Junction Box/Cabinets for all field components of project | item554 | 55 | Nos |
| 604 | 1280 | Online field UPS with Battery Bank for 2 hours | item555 | 55 | Nos |
| 605 | 1281 | HDPE Pipe - 50 mm | item556 | 1 | Lot |
| 606 | 1282 | HDPE Pipe - 90 mm | item557 | 1 | Lot |
| 607 | 1283 | DWC Pipe - 90 mm | item558 | 1 | Lot |
| 608 | 1284 | DWC Pipe - 120 mm | item559 | 1 | Lot |
| 609 | 1285 | Electrical Cable - 3 Core,2.5 Sqmm Unarmoured Cable | item560 | 1 | Lot |
| 610 | 1286 | Electrical Cable - 3 Core,2.5 Sqmm armoured Cable | item561 | 1 | Lot |
| 611 | 1287 | Electrical Cable - 7 Core,1.5 Sqmm Armoured Cable | item562 | 1 | Lot |
| 612 | 1288 | Electrical Cable - 14 Core,1.5 Sqmm Armoured Cable | item563 | 1 | Lot |
| 613 | 1289 | Any other Item | item564 | 1 | Number |
| 614 | 1290 | Comprehensive AMC for 2nd Year of Operation and Maintenance - Traffic Enforcement and Surveillance | |||
| 615 | 1291 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 8 lanes (2 Lanes in each arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illuminator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item565 | 12 | Traffic Junction |
| 616 | 1292 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 3 arms & 6 lanes (2 lanes in each Arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item566 | 4 | Traffic Junction |
| 617 | 1293 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 6 lanes (2 Lanes in 2 Arms each and 1 lane in remaing 2 Arms each) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item567 | 1 | Traffic Junction |
| 618 | 1294 | Speed Detection System for covering 2 lanes in one direction with complete subcomponents including ANPR camera, wide angle evidence camera, IR illuminator, non intrusive speed sensor with cabling & mounting infrastructure as required | item568 | 20 | Location |
| 619 | 1295 | ANPR System for capturing number plates at 2 arms and 4 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item569 | 5 | Location |
| 620 | 1296 | ANPR System for capturing number plates at 2 arms and 6 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item570 | 6 | Location |
| 621 | 1297 | Wrong way detection System covering 1 arm and 1 lane at each Location with complete hardware including ANPR camera, cabling, accessories and mounting infrastructure as required | item571 | 8 | Location |
| 622 | 1298 | Traffic Surveillance PTZ Cameras System with Complete mounting accessories as required | item572 | 6 | Number |
| 623 | 1299 | Traffic Surveillance Overview/Fixed box Cameras System with required Hardware and Softwae including Local Processing Unit, cabling, accessories & mounting infrastructure as required | item573 | 122 | Number |
| 624 | 1300 | Poles for Cameras and Equipments | item574 | 42 | Number |
| 625 | 1301 | E-Challan Handheld Device including Software | item575 | 15 | Number |
| 626 | 1302 | Indoor Fixed Dome Cameras for internal surveillance | item576 | 420 | Number |
| 627 | 1303 | 2 Megapixel Full HD IR IP Vandal proof Bullet Camera with Varifocal Lens | item577 | 140 | Number |
| 628 | 1304 | 8 channel Network Video Recorder (NVR) | item578 | 70 | Number |
| 629 | 1305 | 32\" LED display | item579 | 70 | Number |
| 630 | 1306 | Video Channel License | item580 | 560 | Number |
| 631 | 1307 | 8 Port Managed PoE/PoE+ Network switch | item581 | 70 | Number |
| 632 | 1308 | SFP (1G) Short haul | item582 | 140 | Number |
| 633 | 1309 | Fibre Patch cords 2 metres | item583 | 140 | Units |
| 634 | 1310 | Networking (CAT6) cable | item584 | 1 | Lot |
| 635 | 1311 | Flexible Power cables 3 core, 1.5 sq. mm copper cable | item585 | 1 | Lot |
| 636 | 1312 | PVC Pipe 22 mm diameter | item586 | 1 | Lot |
| 637 | 1313 | UPS with 1 hour backup | item587 | 70 | Number |
| 638 | 1314 | 9U Rack | item588 | 70 | Number |
| 639 | 1315 | Any Other Item | item589 | 1 | Number |
| 640 | 1316 | Comprehensive AMC for 2nd Year of Operation and Maintenance - Adaptive Traffic Control System | |||
| 641 | 1317 | ATCS Traffic Controller with all mounting accessaries | item590 | 17 | Number |
| 642 | 1318 | Countdown timer (CDT) with all mounting accessaries | item591 | 126 | Number |
| 643 | 1319 | Vehicle Detector Camera with all mounting accessaries | item592 | 63 | Number |
| 644 | 1320 | Cantilever poles | item593 | 63 | Number |
| 645 | 1321 | Standard poles for Traffic Signals | item594 | 97 | Number |
| 646 | 1322 | Traffic Light Aspects - Red | item595 | 189 | Number |
| 647 | 1323 | Traffic Light Aspects - Green (Green Straight, Green Right, Green Left) | item596 | 531 | Number |
| 648 | 1324 | Traffic Light Aspects - Amber | item597 | 189 | Number |
| 649 | 1325 | Pedestrian lamp heads - Stop & Walk Man | item598 | 126 | Number |
| 650 | 1326 | 3 Core,2.5 Sqmm Unarmoured Cable | item599 | 1 | Lot |
| 651 | 1327 | 3 Core, 2.5 Sqmm Armoured Cable | item600 | 1 | Lot |
| 652 | 1328 | 7 Core, 1.5 Sqmm Armoured Cable | item601 | 1 | Lot |
| 653 | 1329 | 14 Core, 1.5 Sqmm Armoured Cable | item602 | 1 | Lot |
| 654 | 1330 | Any other item | item603 | 1 | Number |
| 655 | 1331 | Comprehensive AMC for 2nd Year of Operation and Maintenance - Variable Messaging Display and Environmental Sensors | |||
| 656 | 1332 | VMD (3 x 1.5m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item604 | 4 | Number |
| 657 | 1333 | VMD (8 x 3m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item605 | 7 | Number |
| 658 | 1334 | Environmental sensors including all cabling and mounting accessories | item606 | 2 | Number |
| 659 | 1335 | Any other Item | item607 | 1 | Number |
| 660 | 1336 | Comprehensive AMC for 2nd Year of Operation and Maintenance - Smart Street Lights | |||
| 661 | 1337 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 6 LED Fixures with necessary communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure | item608 | 17 | Number |
| 662 | 1338 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 8 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item609 | 11 | Number |
| 663 | 1339 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 12 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item610 | 6 | Number |
| 664 | 1340 | Street light Controller & dimming driver for existing functional LED Street Lights 100W to 300W each on Single/ Double/ Triple poles with capability to handle/ control the min 10 Nos to Max 100 Nos of LED Street Light Poles per feeder panel commmununication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item611 | 104 | Number |
| 665 | 1341 | Any Other Item | item612 | 1 | Number |
| 666 | 1342 | Comprehensive AMC for 2nd Year of Operation and Maintenance - Smart Parking | |||
| 667 | 1343 | Magenetic sensor - surface mount | item613 | 325 | Number |
| 668 | 1344 | Networking/Communication for magnetic sensors including all necessary cablings and accessories | item614 | 7 | Lot |
| 669 | 1345 | Handheld device with scanner and printer with 8 hrs battery backup at full load with networking capability to command centre or Mobile POS device | item615 | 15 | Number |
| 670 | 1346 | Any other Item | item616 | 1 | Number |
| 671 | 1347 | SMS Services for 2nd Year of Operation and Maintenance | |||
| 672 | 1348 | SMS Services (10000 sms pack) per Year | item617 | 1 | Number |
| 673 | 1349 | Comprehensive AMC for 2nd Year of Operation and Maintenance -Leased Line | |||
| 674 | 1350 | Internet Leased Line for ICCC of 100 Mbps | item618 | 2 | Number |
| 675 | 1351 | Leased Line connectivity between DC and DR of 100 Mbps | item619 | 2 | Number |
| 676 | 1352 | Leased Line bandwidth of 2 Mbps Link Between ICCC and end remote locations | item620 | 16 | Number |
| 677 | 1353 | Leased Line bandwidth of 5 Mbps Link Between ICCC and end remote locations | item621 | 3 | Number |
| 678 | 1354 | Leased Line bandwidth of 10 Mbps Link Between ICCC and end remote locations | item622 | 1 | Number |
| 679 | 1355 | Leased Line bandwidth of 20 Mbps Link Between ICCC and end remote locations | item623 | 24 | Number |
| 680 | 1356 | Leased Line bandwidth of 30 Mbps Link Between ICCC and end remote locations | item624 | 82 | Number |
| 681 | 1357 | Leased Line bandwidth of 40 Mbps Link Between ICCC and end remote locations | item625 | 1 | Number |
| 682 | 1358 | Leased Line bandwidth of 50 Mbps Link Between ICCC and end remote locations | item626 | 4 | Number |
| 683 | 1359 | Leased line to connect DC with checkpost locations 20 Mbps | item627 | 6 | Number |
| 684 | 1360 | DR Infra on cloud services for 2nd Year of Operation and Maintenance | |||
| 685 | 1361 | DR Infra on cloud - Server and Storage | item628 | 1 | Number |
| 686 | 1362 | Manpower for 2nd Year of Operation and Maintenance | |||
| 687 | 1363 | Project Manager - Onsite | item629 | 1 | Number |
| 688 | 1364 | Technical Expert- Command & Control Center - Onsite | item630 | 1 | Number |
| 689 | 1365 | Technical Expert – Server and storage - Onsite | item631 | 1 | Number |
| 690 | 1366 | Technical Expert – Video Surveillance and IoT devices - Onsite | item632 | 1 | Number |
| 691 | 1367 | Technical Expert – Networking, EMS/NMS & Software Application - Onsite | item633 | 1 | Number |
| 692 | 1368 | Database Administrator - Offsite | item634 | 1 | Number |
| 693 | 1369 | Cybersecurity Expert - Onsite | item635 | 1 | Number |
| 694 | 1370 | GIS Expert - Onsite | item636 | 1 | Number |
| 695 | 1371 | ERP Developer - Onsite | item637 | 1 | Number |
| 696 | 1372 | Data entry Operator - Onsite | item638 | 1 | Number |
| 697 | 1373 | CCC Supervisors (one per shift) - Onsite | item639 | 2 | Number |
| 698 | 1374 | Helpdesk Staff (2 per shift) - Onsite | item640 | 4 | Number |
| 699 | 1375 | Field Staff (2 per shift) - Onsite | item641 | 4 | Number |
| 700 | 1376 | Training for 2nd Year of Operation and Maintenance | |||
| 701 | 1377 | Refresher Training | item642 | 6 | Batches |
| 702 | 1378 | Audit for 2nd Year of Operation and Maintenance | |||
| 703 | 1379 | IT Audit | item643 | 1 | Lot |
| 704 | 1380 | Comprehensive AMC for 2nd Year of Operation and Maintenance of Non-ICT components | |||
| 705 | 1381 | Operation and Maintenance of Electrical Including Diesel Cost for running of DG Set. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item644 | 1 | Lumpsum |
| 706 | 1382 | Operation and Maintenance of HVAC. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item645 | 1 | Lumpsum |
| 707 | 1383 | Operation and Maintenance of Fire Fighting. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item646 | 1 | Lumpsum |
| 708 | 1384 | Operation and Maintenance of Furniture. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item647 | 1 | Lumpsum |
| 709 | 1385 | Comprehensive AMC for 3rd Year of Operation and Maintenance - Command and Control Centre | |||
| 710 | 1386 | Video Wall Solution- 55\" LED (Matrix of 4*3) | item648 | 12 | Number |
| 711 | 1387 | Video wall controller with cabling and other fixture and wall management software | item649 | 1 | Lot |
| 712 | 1388 | Operator Workstation (CCC and NOC) with 2 monitors (22\") with office productivity suite licenses | item650 | 28 | Number |
| 713 | 1389 | Operator Workstation (Helpdesk) with 1 monitor (22\") with office productivity suite licenses | item651 | 10 | Number |
| 714 | 1390 | Laptop for higher management with office productivity suite licenses | item652 | 2 | Number |
| 715 | 1391 | Network Colour Laser Printer (A3) | item653 | 1 | Number |
| 716 | 1392 | Network B/w Laser Printers (A4) | item654 | 2 | Number |
| 717 | 1393 | Network B/w Heavy Duty Laser Printers | item655 | 1 | Number |
| 718 | 1394 | Multi Function Printer (MFP) | item656 | 2 | Number |
| 719 | 1395 | IP Phone | item657 | 51 | Number |
| 720 | 1396 | Indoor Fixed Dome Cameras for internal surveillance | item658 | 25 | Number |
| 721 | 1397 | Wifi Access for CCC | item659 | 1 | Lot |
| 722 | 1398 | Networking Cost (Passive Components such as LAN/CAT 6 Cabling) | item660 | 1 | Lumpsum |
| 723 | 1399 | Electrical Cabling & Necessary Illumination Devices for CCC, War Room, Helpdesk room, NOC room, Manager(s) room etc. | item661 | 1 | Lumpsum |
| 724 | 1400 | IP PABX for CCC including all accesories | item662 | 1 | Lot |
| 725 | 1401 | Digital Set top box | item663 | 2 | Number |
| 726 | 1402 | Video Conferencing Unit | item664 | 1 | Number |
| 727 | 1403 | 55\" LED display to present critical information Display (War Room) | item665 | 1 | Number |
| 728 | 1404 | Microphone with respective accessories | item666 | 15 | Number |
| 729 | 1405 | Headphones | item667 | 10 | Number |
| 730 | 1406 | PRI Line (Pair) with all necessary accessories | item668 | 1 | Number |
| 731 | 1407 | SMS Gateway modem | item669 | 1 | Number |
| 732 | 1408 | Any other item | item670 | 1 | Number |
| 733 | 1409 | Comprehensive AMC for 3rd Year of Operation and Maintenance - DC Hardware | |||
| 734 | 1410 | Core Router | item671 | 2 | Number |
| 735 | 1411 | Core Switch | item672 | 2 | Number |
| 736 | 1412 | L3 Switch | item673 | 1 | Lot |
| 737 | 1413 | L2 Switch | item674 | 1 | Lot |
| 738 | 1414 | Server load balancer | item675 | 2 | Number |
| 739 | 1415 | Networking Cost (Passive Components) | item676 | 1 | Lumpsum |
| 740 | 1416 | Internet Router | item677 | 2 | Number |
| 741 | 1417 | KVM Switch/Module | item678 | 1 | Number |
| 742 | 1418 | 42 U Racks for Networking | item679 | 2 | Number |
| 743 | 1419 | 42 U Racks for servers and storage | item680 | 8 | Number |
| 744 | 1420 | Online UPS with battery backup | item681 | 1 | Number |
| 745 | 1421 | Storage with 2 no. of SAN Switches & Complete mounting accessories | item682 | 1 | Lot |
| 746 | 1422 | Storage - Tape Drive & Library | item683 | 1 | Lot |
| 747 | 1423 | Blade Servers & Chassis | item684 | 1 | Lot |
| 748 | 1424 | Firewall (External) {1+1 in HA Mode} | item685 | 2 | Number |
| 749 | 1425 | Firewall (Internal) {1+1 in HA Mode} | item686 | 2 | Number |
| 750 | 1426 | Data Loss Protection (DLP) | item687 | 1 | Lot |
| 751 | 1427 | Anti - Advanced Persistent Threat (Anti-APT) | item688 | 1 | Lot |
| 752 | 1428 | Anti - Distributed Denial of Service (DDoS) | item689 | 1 | Lot |
| 753 | 1429 | Security Information and Event Management (SIEM) | item690 | 1 | Lot |
| 754 | 1430 | Network Access Control (NAC) including Patch Management | item691 | 1 | Lot |
| 755 | 1431 | IDAM Solution (1+1 in HA mode) | item692 | 1 | Lot |
| 756 | 1432 | Host Intrusion Prevention System (HIPS) | item693 | 1 | Lot |
| 757 | 1433 | Web Application Firewall (WAF) | item694 | 1 | Lot |
| 758 | 1434 | Any other Item | item695 | 1 | Number |
| 759 | 1435 | Comprehensive AMC for 3rd Year of Operation and Maintenance - DC Applications and Software | |||
| 760 | 1436 | Enterprise Management System(including SLA Mgmt, Helpdesk Mgmt, Network Mgmt, BMS) | item696 | 1 | Lot |
| 761 | 1437 | Backup software | item697 | 1 | Lot |
| 762 | 1438 | Virtualization Software | item698 | 1 | Lot |
| 763 | 1439 | DRM (DC-DR Sync) Software | item699 | 1 | Lot |
| 764 | 1440 | Anti-virus (Software) for workstations | item700 | 40 | Number |
| 765 | 1441 | Anti-Virus for Server | item701 | 1 | Lot |
| 766 | 1442 | ICCC Software with Perpetual License and unlimited sensors | item702 | 1 | LS |
| 767 | 1443 | Call Centre Management (Software) | item703 | 1 | LS |
| 768 | 1444 | Video Management Software | item704 | 1 | Number |
| 769 | 1445 | Central Management Software for detetcting RLVD, No Helmet and Triple Riding | item705 | 1 | Lot |
| 770 | 1446 | Central Management Software for detecting Wrong way | item706 | 1 | Lot |
| 771 | 1447 | Central Management Software for detecting Speed violation | item707 | 1 | Lot |
| 772 | 1448 | Enterprise violations management system for fines and connectivity with vahan and sarathi for auto vehicle identification and fines registry | item708 | 1 | Lot |
| 773 | 1449 | Variable Messaging Display Software | item709 | 1 | Lot |
| 774 | 1450 | Centralized Software for Smart Street Lights (Including Mobile Apps) | item710 | 1 | Lot |
| 775 | 1451 | Smart Parking Software including Dashboarding, reporting & Analytic tools | item711 | 1 | Lot |
| 776 | 1452 | Smart Parking POS software | item712 | 1 | Lot |
| 777 | 1453 | GIS Platform License (server based) | item713 | 1 | Number |
| 778 | 1454 | GIS Platform - Desktop (Editing license) | item714 | 3 | Number |
| 779 | 1455 | ATCS Software Solution | item715 | 1 | Lot |
| 780 | 1456 | Software license for Database server | item716 | 1 | Lot |
| 781 | 1457 | Software license per servers | item717 | 1 | Lot |
| 782 | 1458 | Software license for web server | item718 | 1 | Lot |
| 783 | 1459 | Any other item | item719 | 1 | Number |
| 784 | 1460 | Comprehensive AMC for 3rd Year of Operation and Maintenance - ERP , Mobile Application and Web-portal | |||
| 785 | 1461 | Software support cost for ERP application and licenses | item720 | 1 | Lot |
| 786 | 1462 | Software support cost for Web Portal & Mobile Application | item721 | 1 | Lot |
| 787 | 1463 | Any other Item | item722 | 1 | Number |
| 788 | 1464 | Comprehensive AMC for 3rd Year of Operation and Maintenance - GIS | |||
| 789 | 1465 | GIS Application suite | item724 | 1 | Lot |
| 790 | 1466 | Any other item | item725 | 1 | Number |
| 791 | 1467 | Comprehensive AMC for 3rd Year of Operation and Maintenance - Active and Passive components including junction box | |||
| 792 | 1468 | Access Switch L2 Industrial Grade with SFP and Patch Cord | item727 | 72 | Nos |
| 793 | 1469 | Fibre Patch cords 20 metres | item728 | 55 | Units |
| 794 | 1470 | Electricity Metres at Junction Boxes | item729 | 55 | Units |
| 795 | 1471 | Field Junction Box/Cabinets for all field components of project | item730 | 55 | Nos |
| 796 | 1472 | Online field UPS with Battery Bank for 2 hours | item731 | 55 | Nos |
| 797 | 1473 | HDPE Pipe - 50 mm | item732 | 1 | Lot |
| 798 | 1474 | HDPE Pipe - 90 mm | item733 | 1 | Lot |
| 799 | 1475 | DWC Pipe - 90 mm | item734 | 1 | Lot |
| 800 | 1476 | DWC Pipe - 120 mm | item735 | 1 | Lot |
| 801 | 1477 | Electrical Cable - 3 Core,2.5 Sqmm Unarmoured Cable | item736 | 1 | Lot |
| 802 | 1478 | Electrical Cable - 3 Core,2.5 Sqmm armoured Cable | item737 | 1 | Lot |
| 803 | 1479 | Electrical Cable - 7 Core,1.5 Sqmm Armoured Cable | item738 | 1 | Lot |
| 804 | 1480 | Electrical Cable - 14 Core,1.5 Sqmm Armoured Cable | item739 | 1 | Lot |
| 805 | 1481 | Any other Item | item740 | 1 | Number |
| 806 | 1482 | Comprehensive AMC for 3rd Year of Operation and Maintenance - Traffic Enforcement and Surveillance | |||
| 807 | 1483 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 8 lanes (2 Lanes in each arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illuminator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item741 | 12 | Traffic Junction |
| 808 | 1484 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 3 arms & 6 lanes (2 lanes in each Arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item742 | 4 | Traffic Junction |
| 809 | 1485 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 6 lanes (2 Lanes in 2 Arms each and 1 lane in remaing 2 Arms each) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item743 | 1 | Traffic Junction |
| 810 | 1486 | Speed Detection System for covering 2 lanes in one direction with complete subcomponents including ANPR camera, wide angle evidence camera, IR illuminator, non intrusive speed sensor with cabling & mounting infrastructure as required | item744 | 20 | Location |
| 811 | 1487 | ANPR System for capturing number plates at 2 arms and 4 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item745 | 5 | Location |
| 812 | 1488 | ANPR System for capturing number plates at 2 arms and 6 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item746 | 6 | Location |
| 813 | 1489 | Wrong way detection System covering 1 arm and 1 lane at each Location with complete hardware including ANPR camera, cabling, accessories and mounting infrastructure as required | item747 | 8 | Location |
| 814 | 1490 | Traffic Surveillance PTZ Cameras System with Complete mounting accessories as required | item748 | 6 | Number |
| 815 | 1491 | Traffic Surveillance Overview/Fixed box Cameras System with required Hardware and Softwae including Local Processing Unit, cabling, accessories & mounting infrastructure as required | item749 | 122 | Number |
| 816 | 1492 | Poles for Cameras and Equipments | item750 | 42 | Number |
| 817 | 1493 | E-Challan Handheld Device including Software | item751 | 15 | Number |
| 818 | 1494 | Indoor Fixed Dome Cameras for internal surveillance | item752 | 420 | Number |
| 819 | 1495 | 2 Megapixel Full HD IR IP Vandal proof Bullet Camera with Varifocal Lens | item753 | 140 | Number |
| 820 | 1496 | 8 channel Network Video Recorder (NVR) | item754 | 70 | Number |
| 821 | 1497 | 32\" LED display | item755 | 70 | Number |
| 822 | 1498 | Video Channel License | item756 | 560 | Number |
| 823 | 1499 | 8 Port Managed PoE/PoE+ Network switch | item757 | 70 | Number |
| 824 | 1500 | SFP (1G) Short haul | item758 | 140 | Number |
| 825 | 1501 | Fibre Patch cords 2 metres | item759 | 140 | Units |
| 826 | 1502 | Networking (CAT6) cable | item760 | 1 | Lot |
| 827 | 1503 | Flexible Power cables 3 core, 1.5 sq. mm copper cable | item761 | 1 | Lot |
| 828 | 1504 | PVC Pipe 22 mm diameter | item762 | 1 | Lot |
| 829 | 1505 | UPS with 1 hour backup | item763 | 70 | Number |
| 830 | 1506 | 9U Rack | item764 | 70 | Number |
| 831 | 1507 | Any Other Item | item765 | 1 | Number |
| 832 | 1508 | Comprehensive AMC for 3rd Year of Operation and Maintenance - Adaptive Traffic Control System | |||
| 833 | 1509 | ATCS Traffic Controller with all mounting accessaries | item766 | 17 | Number |
| 834 | 1510 | Countdown timer (CDT) with all mounting accessaries | item767 | 126 | Number |
| 835 | 1511 | Vehicle Detector Camera with all mounting accessaries | item768 | 63 | Number |
| 836 | 1512 | Cantilever poles | item769 | 63 | Number |
| 837 | 1513 | Standard poles for Traffic Signals | item770 | 97 | Number |
| 838 | 1514 | Traffic Light Aspects - Red | item771 | 189 | Number |
| 839 | 1515 | Traffic Light Aspects - Green (Green Straight, Green Right, Green Left) | item772 | 531 | Number |
| 840 | 1516 | Traffic Light Aspects - Amber | item773 | 189 | Number |
| 841 | 1517 | Pedestrian lamp heads - Stop & Walk Man | item774 | 126 | Number |
| 842 | 1518 | 3 Core,2.5 Sqmm Unarmoured Cable | item775 | 1 | Lot |
| 843 | 1519 | 3 Core, 2.5 Sqmm Armoured Cable | item776 | 1 | Lot |
| 844 | 1520 | 7 Core, 1.5 Sqmm Armoured Cable | item777 | 1 | Lot |
| 845 | 1521 | 14 Core, 1.5 Sqmm Armoured Cable | item778 | 1 | Lot |
| 846 | 1522 | Any other item | item779 | 1 | Number |
| 847 | 1523 | Comprehensive AMC for 3rd Year of Operation and Maintenance - Variable Messaging Display and Environmental Sensors | |||
| 848 | 1524 | VMD (3 x 1.5m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item780 | 4 | Number |
| 849 | 1525 | VMD (8 x 3m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item781 | 7 | Number |
| 850 | 1526 | Environmental sensors including all cabling and mounting accessories | item782 | 2 | Number |
| 851 | 1527 | Any other Item | item783 | 1 | Number |
| 852 | 1528 | Comprehensive AMC for 3rd Year of Operation and Maintenance - Smart Street Lights | |||
| 853 | 1529 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 6 LED Fixures with necessary communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure | item784 | 17 | Number |
| 854 | 1530 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 8 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item785 | 11 | Number |
| 855 | 1531 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 12 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item786 | 6 | Number |
| 856 | 1532 | Street light Controller & dimming driver for existing functional LED Street Lights 100W to 300W each on Single/ Double/ Triple poles with capability to handle/ control the min 10 Nos to Max 100 Nos of LED Street Light Poles per feeder panel commmununication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item787 | 104 | Number |
| 857 | 1533 | Any Other Item | item788 | 1 | Number |
| 858 | 1534 | Comprehensive AMC for 3rd Year of Operation and Maintenance - Smart Parking | |||
| 859 | 1535 | Magenetic sensor - surface mount | item789 | 325 | Number |
| 860 | 1536 | Networking/Communication for magnetic sensors including all necessary cablings and accessories | item790 | 7 | Lot |
| 861 | 1537 | Handheld device with scanner and printer with 8 hrs battery backup at full load with networking capability to command centre or Mobile POS device | item791 | 15 | Number |
| 862 | 1538 | Any other Item | item792 | 1 | Number |
| 863 | 1539 | SMS Services for 3rd Year of Operation and Maintenance | |||
| 864 | 1540 | SMS Services (10000 sms pack) per Year | item793 | 1 | Number |
| 865 | 1541 | Bandwidth Services for 3rd Year of Operation and Maintenance | |||
| 866 | 1542 | Internet Leased Line for ICCC of 100 Mbps | item794 | 2 | Number |
| 867 | 1543 | Leased Line connectivity between DC and DR of 100 Mbps | item795 | 2 | Number |
| 868 | 1544 | Leased Line bandwidth of 2 Mbps Link Between ICCC and end remote locations | item796 | 16 | Number |
| 869 | 1545 | Leased Line bandwidth of 5 Mbps Link Between ICCC and end remote locations | item797 | 3 | Number |
| 870 | 1546 | Leased Line bandwidth of 10 Mbps Link Between ICCC and end remote locations | item798 | 1 | Number |
| 871 | 1547 | Leased Line bandwidth of 20 Mbps Link Between ICCC and end remote locations | item799 | 24 | Number |
| 872 | 1548 | Leased Line bandwidth of 30 Mbps Link Between ICCC and end remote locations | item800 | 82 | Number |
| 873 | 1549 | Leased Line bandwidth of 40 Mbps Link Between ICCC and end remote locations | item801 | 1 | Number |
| 874 | 1550 | Leased Line bandwidth of 50 Mbps Link Between ICCC and end remote locations | item802 | 4 | Number |
| 875 | 1551 | Leased line to connect DC with checkpost locations 20 Mbps | item803 | 6 | Number |
| 876 | 1552 | DR Infra on cloud services for 3rd Year of Operation and Maintenance | |||
| 877 | 1553 | DR Infra on cloud - Server and Storage | item804 | 1 | Number |
| 878 | 1554 | Manpower for 3rd Year of Operation and Maintenance | |||
| 879 | 1555 | Project Manager - Onsite | item805 | 1 | Number |
| 880 | 1556 | Technical Expert- Command & Control Center - Onsite | item806 | 1 | Number |
| 881 | 1557 | Technical Expert – Server and storage - Onsite | item807 | 1 | Number |
| 882 | 1558 | Technical Expert – Video Surveillance and IoT devices - Onsite | item808 | 1 | Number |
| 883 | 1559 | Technical Expert – Networking, EMS/NMS & Software Application - Onsite | item809 | 1 | Number |
| 884 | 1560 | Database Administrator - Offsite | item810 | 1 | Number |
| 885 | 1561 | Cybersecurity Expert - Offsite | item811 | 1 | Number |
| 886 | 1562 | GIS Expert - Onsite | item812 | 1 | Number |
| 887 | 1563 | ERP Developer - Onsite | item813 | 1 | Number |
| 888 | 1564 | Data entry Operator - Onsite | item814 | 1 | Number |
| 889 | 1565 | CCC Supervisors (one per shift) - Onsite | item815 | 2 | Number |
| 890 | 1566 | Helpdesk Staff (2 per shift) - Onsite | item816 | 4 | Number |
| 891 | 1567 | Field Staff (2 per shift) - Onsite | item817 | 4 | Number |
| 892 | 1568 | Training for 3rd Year of Operation and Maintenance | |||
| 893 | 1569 | Refresher Training | item818 | 6 | Batches |
| 894 | 1570 | Audit for 3rd Year of Operation and Maintenance | |||
| 895 | 1571 | IT Audit | item819 | 1 | Lot |
| 896 | 1572 | Comprehensive AMC for 3rd Year of Operation and Maintenance - Non-ICT components | |||
| 897 | 1573 | Operation and Maintenance of Electrical Including Diesel Cost for running of DG Set. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item820 | 1 | Lumpsum |
| 898 | 1574 | Operation and Maintenance of HVAC. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item821 | 1 | Lumpsum |
| 899 | 1575 | Operation and Maintenance of Fire Fighting. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item822 | 1 | Lumpsum |
| 900 | 1576 | Operation and Maintenance of Furniture. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item823 | 1 | Lumpsum |
| 901 | 1577 | Comprehensive AMC for 4th Year of Operation and Maintenance - Command and Control Centre | |||
| 902 | 1578 | Video Wall Solution- 55\" LED (Matrix of 4*3) | item824 | 12 | Number |
| 903 | 1579 | Video wall controller with cabling and other fixture and wall management software | item825 | 1 | Lot |
| 904 | 1580 | Operator Workstation (CCC and NOC) with 2 monitors (22\") with office productivity suite licenses | item826 | 28 | Number |
| 905 | 1581 | Operator Workstation (Helpdesk) with 1 monitor (22\") with office productivity suite licenses | item827 | 10 | Number |
| 906 | 1582 | Laptop for higher management with office productivity suite licenses | item828 | 2 | Number |
| 907 | 1583 | Network Colour Laser Printer (A3) | item829 | 1 | Number |
| 908 | 1584 | Network B/w Laser Printers (A4) | item830 | 2 | Number |
| 909 | 1585 | Network B/w Heavy Duty Laser Printers | item831 | 1 | Number |
| 910 | 1586 | Multi Function Printer (MFP) | item832 | 2 | Number |
| 911 | 1587 | IP Phone | item833 | 51 | Number |
| 912 | 1588 | Indoor Fixed Dome Cameras for internal surveillance | item834 | 25 | Number |
| 913 | 1589 | Wifi Access for CCC | item835 | 1 | Lot |
| 914 | 1590 | Networking Cost (Passive Components such as LAN/CAT 6 Cabling) | item836 | 1 | Lumpsum |
| 915 | 1591 | Electrical Cabling & Necessary Illumination Devices for CCC, War Room, Helpdesk room, NOC room, Manager(s) room etc. | item837 | 1 | Lumpsum |
| 916 | 1592 | IP PABX for CCC including all accesories | item838 | 1 | Lot |
| 917 | 1593 | Digital Set top box | item839 | 2 | Number |
| 918 | 1594 | Video Conferencing Unit | item840 | 1 | Number |
| 919 | 1595 | 55\" LED display to present critical information Display (War Room) | item841 | 1 | Number |
| 920 | 1596 | Microphone with respective accessories | item842 | 15 | Number |
| 921 | 1597 | Headphones | item843 | 10 | Number |
| 922 | 1598 | PRI Line (Pair) with all necessary accessories | item844 | 1 | Number |
| 923 | 1599 | SMS Gateway modem | item845 | 1 | Number |
| 924 | 1600 | Any other item | item846 | 1 | Number |
| 925 | 1601 | Comprehensive AMC for 4th Year of Operation and Maintenance - DC Hardware | |||
| 926 | 1602 | Core Router | item847 | 2 | Number |
| 927 | 1603 | Core Switch | item848 | 2 | Number |
| 928 | 1604 | L3 Switch | item849 | 1 | Lot |
| 929 | 1605 | L2 Switch | item850 | 1 | Lot |
| 930 | 1606 | Server load balancer | item851 | 2 | Number |
| 931 | 1607 | Networking Cost (Passive Components) | item852 | 1 | Lumpsum |
| 932 | 1608 | Internet Router | item853 | 2 | Number |
| 933 | 1609 | KVM Switch/Module | item854 | 1 | Number |
| 934 | 1610 | 42 U Racks for Networking | item855 | 2 | Number |
| 935 | 1611 | 42 U Racks for servers and storage | item856 | 8 | Number |
| 936 | 1612 | Online UPS with battery backup | item857 | 1 | Number |
| 937 | 1613 | Storage with 2 no. of SAN Switches & Complete mounting accessories | item858 | 1 | Lot |
| 938 | 1614 | Storage - Tape Drive & Library | item859 | 1 | Lot |
| 939 | 1615 | Blade Servers & Chassis | item860 | 1 | Lot |
| 940 | 1616 | Firewall (External) {1+1 in HA Mode} | item861 | 2 | Number |
| 941 | 1617 | Firewall (Internal) {1+1 in HA Mode} | item862 | 2 | Number |
| 942 | 1618 | Data Loss Protection (DLP) | item863 | 1 | Lot |
| 943 | 1619 | Anti - Advanced Persistent Threat (Anti-APT) | item864 | 1 | Lot |
| 944 | 1620 | Anti - Distributed Denial of Service (DDoS) | item865 | 1 | Lot |
| 945 | 1621 | Security Information and Event Management (SIEM) | item866 | 1 | Lot |
| 946 | 1622 | Network Access Control (NAC) including Patch Management | item867 | 1 | Lot |
| 947 | 1623 | IDAM Solution (1+1 in HA mode) | item868 | 1 | Lot |
| 948 | 1624 | Host Intrusion Prevention System (HIPS) | item869 | 1 | Lot |
| 949 | 1625 | Web Application Firewall (WAF) | item870 | 1 | Lot |
| 950 | 1626 | Any other Item | item871 | 1 | Number |
| 951 | 1627 | Comprehensive AMC for 4th Year of Operation and Maintenance - DC Applications and Software | |||
| 952 | 1628 | Enterprise Management System(including SLA Mgmt, Helpdesk Mgmt, Network Mgmt, BMS) | item872 | 1 | Lot |
| 953 | 1629 | Backup software | item873 | 1 | Lot |
| 954 | 1630 | Virtualization Software | item874 | 1 | Lot |
| 955 | 1631 | DRM (DC-DR Sync) Software | item875 | 1 | Lot |
| 956 | 1632 | Anti-virus (Software) for workstations | item876 | 40 | Number |
| 957 | 1633 | Anti-Virus for Server | item877 | 1 | Lot |
| 958 | 1634 | ICCC Software with Perpetual License and unlimited sensors | item878 | 1 | LS |
| 959 | 1635 | Call Centre Management (Software) | item879 | 1 | LS |
| 960 | 1636 | Video Management Software | item880 | 1 | Number |
| 961 | 1637 | Central Management Software for detetcting RLVD, No Helmet and Triple Riding | item881 | 1 | Lot |
| 962 | 1638 | Central Management Software for detecting Wrong way | item882 | 1 | Lot |
| 963 | 1639 | Central Management Software for detecting Speed violation | item883 | 1 | Lot |
| 964 | 1640 | Enterprise violations management system for fines and connectivity with vahan and sarathi for auto vehicle identification and fines registry | item884 | 1 | Lot |
| 965 | 1641 | Variable Messaging Display Software | item885 | 1 | Lot |
| 966 | 1642 | Centralized Software for Smart Street Lights (Including Mobile Apps) | item886 | 1 | Lot |
| 967 | 1643 | Smart Parking Software including Dashboarding, reporting & Analytic tools | item887 | 1 | Lot |
| 968 | 1644 | Smart Parking POS software | item888 | 1 | Lot |
| 969 | 1645 | GIS Platform License (server based) | item889 | 1 | Number |
| 970 | 1646 | GIS Platform - Desktop (Editing license) | item890 | 3 | Number |
| 971 | 1647 | ATCS Software Solution | item891 | 1 | Lot |
| 972 | 1648 | Software license for Database server | item892 | 1 | Lot |
| 973 | 1649 | Software license per servers | item893 | 1 | Lot |
| 974 | 1650 | Software license for web server | item894 | 1 | Lot |
| 975 | 1651 | Any other item | item895 | 1 | Number |
| 976 | 1652 | Comprehensive AMC for 4th Year of Operation and Maintenance - ERP , Mobile Application and Web-portal | |||
| 977 | 1653 | Software support cost for ERP application and licenses | item896 | 1 | Lot |
| 978 | 1654 | Software support cost for Web Portal & Mobile Application | item897 | 1 | Lot |
| 979 | 1655 | Any other Item | item898 | 1 | Number |
| 980 | 1656 | Comprehensive AMC for 4th Year of Operation and Maintenance - GIS | |||
| 981 | 1657 | GIS Application suite | item899 | 1 | Lot |
| 982 | 1658 | Any other item | item900 | 1 | Number |
| 983 | 1659 | Comprehensive AMC for 4th Year of Operation and Maintenance - Active and Passive components including junction box | |||
| 984 | 1660 | Access Switch L2 Industrial Grade with SFP and Patch Cord | item901 | 72 | Nos |
| 985 | 1661 | Fibre Patch cords 20 metres | item902 | 55 | Units |
| 986 | 1662 | Electricity Metres at Junction Boxes | item903 | 55 | Units |
| 987 | 1663 | Field Junction Box/Cabinets for all field components of project | item904 | 55 | Nos |
| 988 | 1664 | Online field UPS with Battery Bank for 2 hours | item905 | 55 | Nos |
| 989 | 1665 | HDPE Pipe - 50 mm | item906 | 1 | Lot |
| 990 | 1666 | HDPE Pipe - 90 mm | item907 | 1 | Lot |
| 991 | 1667 | DWC Pipe - 90 mm | item908 | 1 | Lot |
| 992 | 1668 | DWC Pipe - 120 mm | item909 | 1 | Lot |
| 993 | 1669 | Electrical Cable - 3 Core,2.5 Sqmm Unarmoured Cable | item910 | 1 | Lot |
| 994 | 1670 | Electrical Cable - 3 Core,2.5 Sqmm armoured Cable | item911 | 1 | Lot |
| 995 | 1671 | Electrical Cable - 7 Core,1.5 Sqmm Armoured Cable | item912 | 1 | Lot |
| 996 | 1672 | Electrical Cable - 14 Core,1.5 Sqmm Armoured Cable | item913 | 1 | Lot |
| 997 | 1673 | Any other Item | item914 | 1 | Number |
| 998 | 1674 | Comprehensive AMC for 4th Year of Operation and Maintenance - Traffic Enforcement and Surveillance | |||
| 999 | 1675 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 8 lanes (2 Lanes in each arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illuminator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item915 | 12 | Traffic Junction |
| 1000 | 1676 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 3 arms & 6 lanes (2 lanes in each Arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item916 | 4 | Traffic Junction |
| 1001 | 1677 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 6 lanes (2 Lanes in 2 Arms each and 1 lane in remaing 2 Arms each) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item917 | 1 | Traffic Junction |
| 1002 | 1678 | Speed Detection System for covering 2 lanes in one direction with complete subcomponents including ANPR camera, wide angle evidence camera, IR illuminator, non intrusive speed sensor with cabling & mounting infrastructure as required | item918 | 20 | Location |
| 1003 | 1679 | ANPR System for capturing number plates at 2 arms and 4 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item919 | 5 | Location |
| 1004 | 1680 | ANPR System for capturing number plates at 2 arms and 6 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item920 | 6 | Location |
| 1005 | 1681 | Wrong way detection System covering 1 arm and 1 lane at each Location with complete hardware including ANPR camera, cabling, accessories and mounting infrastructure as required | item921 | 8 | Location |
| 1006 | 1682 | Traffic Surveillance PTZ Cameras System with Complete mounting accessories as required | item922 | 6 | Number |
| 1007 | 1683 | Traffic Surveillance Overview/Fixed box Cameras System with required Hardware and Softwae including Local Processing Unit, cabling, accessories & mounting infrastructure as required | item923 | 122 | Number |
| 1008 | 1684 | Poles for Cameras and Equipments | item924 | 42 | Number |
| 1009 | 1685 | E-Challan Handheld Device including Software | item925 | 15 | Number |
| 1010 | 1686 | Indoor Fixed Dome Cameras for internal surveillance | item926 | 420 | Number |
| 1011 | 1687 | 2 Megapixel Full HD IR IP Vandal proof Bullet Camera with Varifocal Lens | item927 | 140 | Number |
| 1012 | 1688 | 8 channel Network Video Recorder (NVR) | item928 | 70 | Number |
| 1013 | 1689 | 32\" LED display | item929 | 70 | Number |
| 1014 | 1690 | Video Channel License | item930 | 560 | Number |
| 1015 | 1691 | 8 Port Managed PoE/PoE+ Network switch | item931 | 70 | Number |
| 1016 | 1692 | SFP (1G) Short haul | item932 | 140 | Number |
| 1017 | 1693 | Fibre Patch cords 2 metres | item933 | 140 | Units |
| 1018 | 1694 | Networking (CAT6) cable | item934 | 1 | Lot |
| 1019 | 1695 | Flexible Power cables 3 core, 1.5 sq. mm copper cable | item935 | 1 | Lot |
| 1020 | 1696 | PVC Pipe 22 mm diameter | item936 | 1 | Lot |
| 1021 | 1697 | UPS with 1 hour backup | item937 | 70 | Number |
| 1022 | 1698 | 9U Rack | item938 | 70 | Number |
| 1023 | 1699 | Any Other Item | item939 | 1 | Number |
| 1024 | 1700 | Comprehensive AMC for 4th Year of Operation and Maintenance - Adaptive Traffic Control System | |||
| 1025 | 1701 | ATCS Traffic Controller with all mounting accessaries | item940 | 17 | Number |
| 1026 | 1702 | Countdown timer (CDT) with all mounting accessaries | item941 | 126 | Number |
| 1027 | 1703 | Vehicle Detector Camera with all mounting accessaries | item942 | 63 | Number |
| 1028 | 1704 | Cantilever poles | item943 | 63 | Number |
| 1029 | 1705 | Standard poles for Traffic Signals | item944 | 97 | Number |
| 1030 | 1706 | Traffic Light Aspects - Red | item945 | 189 | Number |
| 1031 | 1707 | Traffic Light Aspects - Green (Green Straight, Green Right, Green Left) | item946 | 531 | Number |
| 1032 | 1708 | Traffic Light Aspects - Amber | item947 | 189 | Number |
| 1033 | 1709 | Pedestrian lamp heads - Stop & Walk Man | item948 | 126 | Number |
| 1034 | 1710 | 3 Core,2.5 Sqmm Unarmoured Cable | item949 | 1 | Lot |
| 1035 | 1711 | 3 Core, 2.5 Sqmm Armoured Cable | item950 | 1 | Lot |
| 1036 | 1712 | 7 Core, 1.5 Sqmm Armoured Cable | item951 | 1 | Lot |
| 1037 | 1713 | 14 Core, 1.5 Sqmm Armoured Cable | item952 | 1 | Lot |
| 1038 | 1714 | Any other item | item953 | 1 | Number |
| 1039 | 1715 | Comprehensive AMC for 4th Year of Operation and Maintenance - Variable Messaging Display and Environmental Sensors | |||
| 1040 | 1716 | VMD (3 x 1.5m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item954 | 4 | Number |
| 1041 | 1717 | VMD (8 x 3m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item955 | 7 | Number |
| 1042 | 1718 | Environmental sensors including all cabling and mounting accessories | item956 | 2 | Number |
| 1043 | 1719 | Any other Item | item957 | 1 | Number |
| 1044 | 1720 | Comprehensive AMC for 4th Year of Operation and Maintenance - Smart Street Lights | |||
| 1045 | 1721 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 6 LED Fixures with necessary communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure | item958 | 17 | Number |
| 1046 | 1722 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 8 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item959 | 11 | Number |
| 1047 | 1723 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 12 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item960 | 6 | Number |
| 1048 | 1724 | Street light Controller & dimming driver for existing functional LED Street Lights 100W to 300W each on Single/ Double/ Triple poles with capability to handle/ control the min 10 Nos to Max 100 Nos of LED Street Light Poles per feeder panel commmununication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item961 | 104 | Number |
| 1049 | 1725 | Any Other Item | item962 | 1 | Number |
| 1050 | 1726 | Comprehensive AMC for 4th Year of Operation and Maintenance - Smart Parking | |||
| 1051 | 1727 | Magenetic sensor - surface mount | item963 | 325 | Number |
| 1052 | 1728 | Networking/Communication for magnetic sensors including all necessary cablings and accessories | item964 | 7 | Lot |
| 1053 | 1729 | Handheld device with scanner and printer with 8 hrs battery backup at full load with networking capability to command centre or Mobile POS device | item965 | 15 | Number |
| 1054 | 1730 | Any other Item | item966 | 1 | Number |
| 1055 | 1731 | SMS Services for 4th Year of Operation and Maintenance | |||
| 1056 | 1732 | SMS Services (10000 sms pack) per Year | item967 | 1 | Number |
| 1057 | 1733 | Bandwidth Services for 4th Year of Operation and Maintenance | |||
| 1058 | 1734 | Internet Leased Line for ICCC of 100 Mbps | item968 | 2 | Number |
| 1059 | 1735 | Leased Line connectivity between DC and DR of 100 Mbps | item969 | 2 | Number |
| 1060 | 1736 | Leased Line bandwidth of 2 Mbps Link Between ICCC and end remote locations | item970 | 16 | Number |
| 1061 | 1737 | Leased Line bandwidth of 5 Mbps Link Between ICCC and end remote locations | item971 | 3 | Number |
| 1062 | 1738 | Leased Line bandwidth of 10 Mbps Link Between ICCC and end remote locations | item972 | 1 | Number |
| 1063 | 1739 | Leased Line bandwidth of 20 Mbps Link Between ICCC and end remote locations | item973 | 24 | Number |
| 1064 | 1740 | Leased Line bandwidth of 30 Mbps Link Between ICCC and end remote locations | item974 | 82 | Number |
| 1065 | 1741 | Leased Line bandwidth of 40 Mbps Link Between ICCC and end remote locations | item975 | 1 | Number |
| 1066 | 1742 | Leased Line bandwidth of 50 Mbps Link Between ICCC and end remote locations | item976 | 4 | Number |
| 1067 | 1743 | Leased line to connect DC with checkpost locations 20 Mbps | item977 | 6 | Number |
| 1068 | 1744 | DR Infra on cloud for 4th Year of Operation and Maintenance | |||
| 1069 | 1745 | DR Infra on cloud - Server and Storage | item978 | 1 | Number |
| 1070 | 1746 | Manpower for 4th Year of Operation and Maintenance | |||
| 1071 | 1747 | Project Manager - Onsite | item979 | 1 | Number |
| 1072 | 1748 | Technical Expert- Command & Control Center - Onsite | item980 | 1 | Number |
| 1073 | 1749 | Technical Expert – Server and storage - Onsite | item981 | 1 | Number |
| 1074 | 1750 | Technical Expert – Video Surveillance and IoT devices - Onsite | item982 | 1 | Number |
| 1075 | 1751 | Technical Expert – Networking, EMS/NMS & Software Application - Onsite | item983 | 1 | Number |
| 1076 | 1752 | Database Administrator - Offsite | item984 | 1 | Number |
| 1077 | 1753 | Cybersecurity Expert - Offsite | item985 | 1 | Number |
| 1078 | 1754 | GIS Expert - Onsite | item986 | 1 | Number |
| 1079 | 1755 | ERP Developer - Onsite | item987 | 1 | Number |
| 1080 | 1756 | Data entry Operator - Onsite | item988 | 1 | Number |
| 1081 | 1757 | CCC Supervisors (one per shift) - Onsite | item989 | 2 | Number |
| 1082 | 1758 | Helpdesk Staff (2 per shift) - Onsite | item990 | 4 | Number |
| 1083 | 1759 | Field Staff (2 per shift) - Onsite | item991 | 4 | Number |
| 1084 | 1760 | Training | |||
| 1085 | 1761 | Refresher Training | item993 | 6 | Batches |
| 1086 | 1762 | Audit 4th Year of Operation and Maintenance | |||
| 1087 | 1763 | IT Audit | item994 | 1 | Lot |
| 1088 | 1764 | Comprehensive AMC for 4th Year of Operation and Maintenance of Non-ICT components | |||
| 1089 | 1765 | Operation and Maintenance of Electrical Including Diesel Cost for running of DG Set. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item995 | 1 | Lumpsum |
| 1090 | 1766 | Operation and Maintenance of HVAC. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item996 | 1 | Lumpsum |
| 1091 | 1767 | Operation and Maintenance of Fire Fighting. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item997 | 1 | Lumpsum |
| 1092 | 1768 | Operation and Maintenance of Furniture. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item998 | 1 | Lumpsum |
| 1093 | 1769 | Comprehensive AMC for 5th Year of Operation and Maintenance - Command and Control Centre | |||
| 1094 | 1770 | Video Wall Solution- 55\" LED (Matrix of 4*3) | item999 | 12 | Number |
| 1095 | 1771 | Video wall controller with cabling and other fixture and wall management software | item1000 | 1 | Lot |
| 1096 | 1772 | Operator Workstation (CCC and NOC) with 2 monitors (22\") with office productivity suite licenses | item1001 | 28 | Number |
| 1097 | 1773 | Operator Workstation (Helpdesk) with 1 monitor (22\") with office productivity suite licenses | item1002 | 10 | Number |
| 1098 | 1774 | Laptop for higher management with office productivity suite licenses | item1003 | 2 | Number |
| 1099 | 1775 | Network Colour Laser Printer (A3) | item1004 | 1 | Number |
| 1100 | 1776 | Network B/w Laser Printers (A4) | item1005 | 2 | Number |
| 1101 | 1777 | Network B/w Heavy Duty Laser Printers | item1006 | 1 | Number |
| 1102 | 1778 | Multi Function Printer (MFP) | item1007 | 2 | Number |
| 1103 | 1779 | IP Phone | item1008 | 51 | Number |
| 1104 | 1780 | Indoor Fixed Dome Cameras for internal surveillance | item1009 | 25 | Number |
| 1105 | 1781 | Wifi Access for CCC | item1010 | 1 | Lot |
| 1106 | 1782 | Networking Cost (Passive Components such as LAN/CAT 6 Cabling) | item1011 | 1 | Lumpsum |
| 1107 | 1783 | Electrical Cabling & Necessary Illumination Devices for CCC, War Room, Helpdesk room, NOC room, Manager(s) room etc. | item1012 | 1 | Lumpsum |
| 1108 | 1784 | IP PABX for CCC including all accesories | item1013 | 1 | Lot |
| 1109 | 1785 | Digital Set top box | item1014 | 2 | Number |
| 1110 | 1786 | Video Conferencing Unit | item1015 | 1 | Number |
| 1111 | 1787 | 55\" LED display to present critical information Display (War Room) | item1016 | 1 | Number |
| 1112 | 1788 | Microphone with respective accessories | item1017 | 15 | Number |
| 1113 | 1789 | Headphones | item1018 | 10 | Number |
| 1114 | 1790 | PRI Line (Pair) with all necessary accessories | item1019 | 1 | Number |
| 1115 | 1791 | SMS Gateway modem | item1020 | 1 | Number |
| 1116 | 1792 | Any other item | item1021 | 1 | Number |
| 1117 | 1793 | Comprehensive AMC for 5th Year of Operation and Maintenance - DC Hardware | |||
| 1118 | 1794 | Core Router | item1022 | 2 | Number |
| 1119 | 1795 | Core Switch | item1023 | 2 | Number |
| 1120 | 1796 | L3 Switch | item1024 | 1 | Lot |
| 1121 | 1797 | L2 Switch | item1025 | 1 | Lot |
| 1122 | 1798 | Server load balancer | item1026 | 2 | Number |
| 1123 | 1799 | Networking Cost (Passive Components) | item1027 | 1 | Lumpsum |
| 1124 | 1800 | Internet Router | item1028 | 2 | Number |
| 1125 | 1801 | KVM Switch/Module | item1029 | 1 | Number |
| 1126 | 1802 | 42 U Racks for Networking | item1030 | 2 | Number |
| 1127 | 1803 | 42 U Racks for servers and storage | item1031 | 8 | Number |
| 1128 | 1804 | Online UPS with battery backup | item1032 | 1 | Number |
| 1129 | 1805 | Storage with 2 no. of SAN Switches & Complete mounting accessories | item1033 | 1 | Lot |
| 1130 | 1806 | Storage - Tape Drive & Library | item1034 | 1 | Lot |
| 1131 | 1807 | Blade Servers & Chassis | item1035 | 1 | Lot |
| 1132 | 1808 | Firewall (External) {1+1 in HA Mode} | item1036 | 2 | Number |
| 1133 | 1809 | Firewall (Internal) {1+1 in HA Mode} | item1037 | 2 | Number |
| 1134 | 1810 | Data Loss Protection (DLP) | item1038 | 1 | Lot |
| 1135 | 1811 | Anti - Advanced Persistent Threat (Anti-APT) | item1039 | 1 | Lot |
| 1136 | 1812 | Anti - Distributed Denial of Service (DDoS) | item1040 | 1 | Lot |
| 1137 | 1813 | Security Information and Event Management (SIEM) | item1041 | 1 | Lot |
| 1138 | 1814 | Network Access Control (NAC) including Patch Management | item1042 | 1 | Lot |
| 1139 | 1815 | IDAM Solution (1+1 in HA mode) | item1043 | 1 | Lot |
| 1140 | 1816 | Host Intrusion Prevention System (HIPS) | item1044 | 1 | Lot |
| 1141 | 1817 | Web Application Firewall (WAF) | item1045 | 1 | Lot |
| 1142 | 1818 | Any other Item | item1046 | 1 | Number |
| 1143 | 1819 | Comprehensive AMC for 5th Year of Operation and Maintenance - DC Applications and Software | |||
| 1144 | 1820 | Enterprise Management System(including SLA Mgmt, Helpdesk Mgmt, Network Mgmt, BMS) | item1047 | 1 | Lot |
| 1145 | 1821 | Backup software | item1048 | 1 | Lot |
| 1146 | 1822 | Virtualization Software | item1049 | 1 | Lot |
| 1147 | 1823 | DRM (DC-DR Sync) Software | item1050 | 1 | Lot |
| 1148 | 1824 | Anti-virus (Software) for workstations | item1051 | 40 | Number |
| 1149 | 1825 | Anti-Virus for Server | item1052 | 1 | Lot |
| 1150 | 1826 | ICCC Software with Perpetual License and unlimited sensors | item1053 | 1 | LS |
| 1151 | 1827 | Call Centre Management (Software) | item1054 | 1 | LS |
| 1152 | 1828 | Video Management Software | item1055 | 1 | Number |
| 1153 | 1829 | Central Management Software for detetcting RLVD, No Helmet and Triple Riding | item1056 | 1 | Lot |
| 1154 | 1830 | Central Management Software for detecting Wrong way | item1057 | 1 | Lot |
| 1155 | 1831 | Central Management Software for detecting Speed violation | item1058 | 1 | Lot |
| 1156 | 1832 | Enterprise violations management system for fines and connectivity with vahan and sarathi for auto vehicle identification and fines registry | item1059 | 1 | Lot |
| 1157 | 1833 | Variable Messaging Display Software | item1060 | 1 | Lot |
| 1158 | 1834 | Centralized Software for Smart Street Lights (Including Mobile Apps) | item1061 | 1 | Lot |
| 1159 | 1835 | Smart Parking Software including Dashboarding, reporting & Analytic tools | item1062 | 1 | Lot |
| 1160 | 1836 | Smart Parking POS software | item1063 | 1 | Lot |
| 1161 | 1837 | GIS Platform License (server based) | item1064 | 1 | Number |
| 1162 | 1838 | GIS Platform - Desktop (Editing license) | item1065 | 3 | Number |
| 1163 | 1839 | ATCS Software Solution | item1066 | 1 | Lot |
| 1164 | 1840 | Software license for Database server | item1067 | 1 | Lot |
| 1165 | 1841 | Software license per servers | item1068 | 1 | Lot |
| 1166 | 1842 | Software license for web server | item1069 | 1 | Lot |
| 1167 | 1843 | Any other item | item1070 | 1 | Number |
| 1168 | 1844 | Comprehensive AMC for 5th Year of Operation and Maintenance - ERP , Mobile Application and Web-portal | |||
| 1169 | 1845 | Software support cost for ERP application and licenses | item1071 | 1 | Lot |
| 1170 | 1846 | Software support cost for Web Portal & Mobile Application | item1072 | 1 | Lot |
| 1171 | 1847 | Any other Item | item1073 | 1 | Number |
| 1172 | 1848 | GIS | |||
| 1173 | 1849 | GIS Application suite | item1074 | 1 | Lot |
| 1174 | 1850 | Any other item | item1075 | 1 | Number |
| 1175 | 1851 | Active and Passive components including junction box | |||
| 1176 | 1852 | Access Switch L2 Industrial Grade with SFP and Patch Cord | item1076 | 72 | Nos |
| 1177 | 1853 | Fibre Patch cords 20 metres | item1077 | 55 | Units |
| 1178 | 1854 | Electricity Metres at Junction Boxes | item1078 | 55 | Units |
| 1179 | 1855 | Field Junction Box/Cabinets for all field components of project | item1079 | 55 | Nos |
| 1180 | 1856 | Online field UPS with Battery Bank for 2 hours | item1080 | 55 | Nos |
| 1181 | 1857 | HDPE Pipe - 50 mm | item1081 | 1 | Lot |
| 1182 | 1858 | HDPE Pipe - 90 mm | item1082 | 1 | Lot |
| 1183 | 1859 | DWC Pipe - 90 mm | item1083 | 1 | Lot |
| 1184 | 1860 | DWC Pipe - 120 mm | item1084 | 1 | Lot |
| 1185 | 1861 | Electrical Cable - 3 Core,2.5 Sqmm Unarmoured Cable | item1085 | 1 | Lot |
| 1186 | 1862 | Electrical Cable - 3 Core,2.5 Sqmm armoured Cable | item1086 | 1 | Lot |
| 1187 | 1863 | Electrical Cable - 7 Core,1.5 Sqmm Armoured Cable | item1087 | 1 | Lot |
| 1188 | 1864 | Electrical Cable - 14 Core,1.5 Sqmm Armoured Cable | item1088 | 1 | Lot |
| 1189 | 1865 | Any other Item | item1089 | 1 | Number |
| 1190 | 1866 | Comprehensive AMC for 5th Year of Operation and Maintenance - Traffic Enforcement and Surveillance | |||
| 1191 | 1867 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 8 lanes (2 Lanes in each arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illuminator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item1090 | 12 | Traffic Junction |
| 1192 | 1868 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 3 arms & 6 lanes (2 lanes in each Arm) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item1091 | 4 | Traffic Junction |
| 1193 | 1869 | Red Light Voilation Detection (RLVD) System including No Helmet Detection & Triple Riding detection for covering 4 arms & 6 lanes (2 Lanes in 2 Arms each and 1 lane in remaing 2 Arms each) at each junction with complete hardware including ANPR cameras, Overview Cameras, IR Illumiator, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item1092 | 1 | Traffic Junction |
| 1194 | 1870 | Speed Detection System for covering 2 lanes in one direction with complete subcomponents including ANPR camera, wide angle evidence camera, IR illuminator, non intrusive speed sensor with cabling & mounting infrastructure as required | item1093 | 20 | Location |
| 1195 | 1871 | ANPR System for capturing number plates at 2 arms and 4 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item1094 | 5 | Location |
| 1196 | 1872 | ANPR System for capturing number plates at 2 arms and 6 lanes at each Location with complete hardware including ANPR cameras, Local Processing Unit, with cabling, accessories & mounting infrastructure as required | item1095 | 6 | Location |
| 1197 | 1873 | Wrong way detection System covering 1 arm and 1 lane at each Location with complete hardware including ANPR camera, cabling, accessories and mounting infrastructure as required | item1096 | 8 | Location |
| 1198 | 1874 | Traffic Surveillance PTZ Cameras System with Complete mounting accessories as required | item1097 | 6 | Number |
| 1199 | 1875 | Traffic Surveillance Overview/Fixed box Cameras System with required Hardware and Softwae including Local Processing Unit, cabling, accessories & mounting infrastructure as required | item1098 | 122 | Number |
| 1200 | 1876 | Poles for Cameras and Equipments | item1099 | 42 | Number |
| 1201 | 1877 | E-Challan Handheld Device including Software | item1100 | 15 | Number |
| 1202 | 1878 | Indoor Fixed Dome Cameras for internal surveillance | item1101 | 420 | Number |
| 1203 | 1879 | 2 Megapixel Full HD IR IP Vandal proof Bullet Camera with Varifocal Lens | item1102 | 140 | Number |
| 1204 | 1880 | 8 channel Network Video Recorder (NVR) | item1103 | 70 | Number |
| 1205 | 1881 | 32\" LED display | item1104 | 70 | Number |
| 1206 | 1882 | Video Channel License | item1105 | 560 | Number |
| 1207 | 1883 | 8 Port Managed PoE/PoE+ Network switch | item1106 | 70 | Number |
| 1208 | 1884 | SFP (1G) Short haul | item1107 | 140 | Number |
| 1209 | 1885 | Fibre Patch cords 2 metres | item1108 | 140 | Units |
| 1210 | 1886 | Networking (CAT6) cable | item1109 | 1 | Lot |
| 1211 | 1887 | Flexible Power cables 3 core, 1.5 sq. mm copper cable | item1110 | 1 | Lot |
| 1212 | 1888 | PVC Pipe 22 mm diameter | item1111 | 1 | Lot |
| 1213 | 1889 | UPS with 1 hour backup | item1112 | 70 | Number |
| 1214 | 1890 | 9U Rack | item1113 | 70 | Number |
| 1215 | 1891 | Any Other Item | item1114 | 1 | Number |
| 1216 | 1892 | Comprehensive AMC for 5th Year of Operation and Maintenance - Adaptive Traffic Control System | |||
| 1217 | 1893 | ATCS Traffic Controller with all mounting accessaries | item1115 | 17 | Number |
| 1218 | 1894 | Countdown timer (CDT) with all mounting accessaries | item1116 | 126 | Number |
| 1219 | 1895 | Vehicle Detector Camera with all mounting accessaries | item1117 | 63 | Number |
| 1220 | 1896 | Cantilever poles | item1118 | 63 | Number |
| 1221 | 1897 | Standard poles for Traffic Signals | item1119 | 97 | Number |
| 1222 | 1898 | Traffic Light Aspects - Red | item1120 | 189 | Number |
| 1223 | 1899 | Traffic Light Aspects - Green (Green Straight, Green Right, Green Left) | item1121 | 531 | Number |
| 1224 | 1900 | Traffic Light Aspects - Amber | item1122 | 189 | Number |
| 1225 | 1901 | Pedestrian lamp heads - Stop & Walk Man | item1123 | 126 | Number |
| 1226 | 1902 | 3 Core,2.5 Sqmm Unarmoured Cable | item1124 | 1 | Lot |
| 1227 | 1903 | 3 Core, 2.5 Sqmm Armoured Cable | item1125 | 1 | Lot |
| 1228 | 1904 | 7 Core, 1.5 Sqmm Armoured Cable | item1126 | 1 | Lot |
| 1229 | 1905 | 14 Core, 1.5 Sqmm Armoured Cable | item1127 | 1 | Lot |
| 1230 | 1906 | Any other item | item1128 | 1 | Number |
| 1231 | 1907 | Comprehensive AMC for 5th Year of Operation and Maintenance - Variable Messaging Display and Environmental Sensors | |||
| 1232 | 1908 | VMD (3 x 1.5m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item1129 | 4 | Number |
| 1233 | 1909 | VMD (8 x 3m) with Audio enabled and VMD Controller (including its mounting structure, pole inclusive of all civil, electrical, erection, earthing work with necessary foundation for Variable Messaging Display) | item1130 | 7 | Number |
| 1234 | 1910 | Environmental sensors including all cabling and mounting accessories | item1131 | 2 | Number |
| 1235 | 1911 | Any other Item | item1132 | 1 | Number |
| 1236 | 1912 | Comprehensive AMC for 5th Year of Operation and Maintenance - Smart Street Lights | |||
| 1237 | 1913 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 6 LED Fixures with necessary communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure | item1133 | 17 | Number |
| 1238 | 1914 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 8 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item1134 | 11 | Number |
| 1239 | 1915 | Street light Controller & dimming driver for existing functional LED Street Lights 1500-3000W on High Mast poles with 12 LED Fixures with communication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item1135 | 6 | Number |
| 1240 | 1916 | Street light Controller & dimming driver for existing functional LED Street Lights 100W to 300W each on Single/ Double/ Triple poles with capability to handle/ control the min 10 Nos to Max 100 Nos of LED Street Light Poles per feeder panel commmununication/ Connectivity to CCC, Software with updates and upgrades, gateway infrastructure etc. | item1136 | 104 | Number |
| 1241 | 1917 | Any Other Item | item1137 | 1 | Number |
| 1242 | 1918 | Comprehensive AMC for 5th Year of Operation and Maintenance - Smart Parking | |||
| 1243 | 1919 | Magenetic sensor - surface mount | item1138 | 325 | Number |
| 1244 | 1920 | Networking/Communication for magnetic sensors including all necessary cablings and accessories | item1139 | 7 | Lot |
| 1245 | 1921 | Handheld device with scanner and printer with 8 hrs battery backup at full load with networking capability to command centre or Mobile POS device | item1140 | 15 | Number |
| 1246 | 1922 | Any other Item | item1141 | 1 | Number |
| 1247 | 1923 | SMS Services for 5th Year of Operation and Maintenance | |||
| 1248 | 1924 | SMS Services (10000 sms pack) per Year | item1142 | 1 | Number |
| 1249 | 1925 | Bandwidth for 5th Year of Operation and Maintenance | |||
| 1250 | 1926 | Internet Leased Line for ICCC of 100 Mbps | item1143 | 2 | Number |
| 1251 | 1927 | Leased Line connectivity between DC and DR of 100 Mbps | item1144 | 2 | Number |
| 1252 | 1928 | Leased Line bandwidth of 2 Mbps Link Between ICCC and end remote locations | item1145 | 16 | Number |
| 1253 | 1929 | Leased Line bandwidth of 5 Mbps Link Between ICCC and end remote locations | item1146 | 3 | Number |
| 1254 | 1930 | Leased Line bandwidth of 10 Mbps Link Between ICCC and end remote locations | item1147 | 1 | Number |
| 1255 | 1931 | Leased Line bandwidth of 20 Mbps Link Between ICCC and end remote locations | item1148 | 24 | Number |
| 1256 | 1932 | Leased Line bandwidth of 30 Mbps Link Between ICCC and end remote locations | item1149 | 82 | Number |
| 1257 | 1933 | Leased Line bandwidth of 40 Mbps Link Between ICCC and end remote locations | item1150 | 1 | Number |
| 1258 | 1934 | Leased Line bandwidth of 50 Mbps Link Between ICCC and end remote locations | item1151 | 4 | Number |
| 1259 | 1935 | Leased line to connect DC with checkpost locations 20 Mbps | item1152 | 6 | Number |
| 1260 | 1936 | DR Infra on cloud for 5th Year of Operation and Maintenance | |||
| 1261 | 1937 | DR Infra on cloud - Server and Storage | item1153 | 1 | Number |
| 1262 | 1938 | Manpower services for 5th Year of Operation and Maintenance | |||
| 1263 | 1939 | Project Manager - Onsite | item1154 | 1 | Number |
| 1264 | 1940 | Technical Expert- Command & Control Center - Onsite | item1155 | 1 | Number |
| 1265 | 1941 | Technical Expert – Server and storage - Onsite | item1156 | 1 | Number |
| 1266 | 1942 | Technical Expert – Video Surveillance and IoT devices - Onsite | item1157 | 1 | Number |
| 1267 | 1943 | Technical Expert – Networking, EMS/NMS & Software Application - Onsite | item1158 | 1 | Number |
| 1268 | 1944 | Database Administrator - Offsite | item1159 | 1 | Number |
| 1269 | 1945 | Cybersecurity Expert - Offsite | item1160 | 1 | Number |
| 1270 | 1946 | GIS Expert - Onsite | item1161 | 1 | Number |
| 1271 | 1947 | ERP Developer - Onsite | item1162 | 1 | Number |
| 1272 | 1948 | Data entry Operator - Onsite | item1163 | 1 | Number |
| 1273 | 1949 | CCC Supervisors (one per shift) - Onsite | item1164 | 2 | Number |
| 1274 | 1950 | Helpdesk Staff (2 per shift) - Onsite | item1165 | 4 | Number |
| 1275 | 1951 | Field Staff (2 per shift) - Onsite | item1166 | 4 | Number |
| 1276 | 1952 | Training | |||
| 1277 | 1953 | Refresher Training | item1168 | 6 | Batches |
| 1278 | 1954 | Audit for 5th Year of Operation and Maintenance | |||
| 1279 | 1955 | IT Audit | item1170 | 1 | Lot |
| 1280 | 1956 | Comprehensive AMC for 5th Year of Operation and Maintenance of Non-ICT components | |||
| 1281 | 1957 | Operation and Maintenance of Electrical Including Diesel Cost for running of DG Set. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item1171 | 1 | Lumpsum |
| 1282 | 1958 | Operation and Maintenance of HVAC. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item1172 | 1 | Lumpsum |
| 1283 | 1959 | Operation and Maintenance of Fire Fighting. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item1173 | 1 | Lumpsum |
| 1284 | 1960 | Operation and Maintenance of Furniture. The scope of Work includes Quarterly inspection of all System, Preventive Maintenance of all kinds of equipment installed under the Project Part B (Establishment of physical infrastructure) and Training to designated staff twice a year complete work | item1174 | 1 | Lumpsum |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender