| 1 | 1 | Civil Work | | | |
|---|
| 2 | 1.01 | Earth Work | | | |
|---|
| 3 | 1.02 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation\ntrenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and\nramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | | 29.942 | Cum |
|---|
| 4 | 1.03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | | 21.867 | Cum |
|---|
| 5 | 2 | CEMENT CONCRETE | | | |
|---|
| 6 | 2.01 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and\nshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | | 3.645 | Cum |
|---|
| 7 | 3 | R.C.C. Work | | | |
|---|
| 8 | 3.01 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). | | 1.683 | Cum |
|---|
| 9 | 4 | Form Work | | | |
|---|
| 10 | 4.01 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | | 11.4 | Sqm |
|---|
| 11 | 4.02 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | | 72 | Kg |
|---|
| 12 | 5 | MASONRY WORKS | | | |
|---|
| 13 | 5.01 | Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement\nmortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. | | 6.994 | Cum |
|---|
| 14 | 5.02 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 | | 29.942 | Cum |
|---|
| 15 | 6 | PLASTERING | | | |
|---|
| 16 | 6.01 | 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) | | 52.781 | Sqm |
|---|
| 17 | 7 | Steel Work | | | |
|---|
| 18 | 7.01 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | | 790.257 | Kg |
|---|
| 19 | 7.02 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,\nincluding welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the\nsame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary\naccessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) | | 19.895 | Kg |
|---|
| 20 | 7.03 | Providing at all heights, levels and locations 0.45 mm thick Galvalume sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces\ni/c cutting to size and shape where required as per the direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealant where required etc. but excluding the cost of purlins, rafters and trusses. | | 126.5 | Sqm |
|---|
| 21 | 7.04 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter | | 11 | M |
|---|
| 22 | 8 | ALUMINIUM WORKS | | | |
|---|
| 23 | 8.01 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,\npaneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) | | 135.84 | Kg |
|---|
| 24 | 8.02 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) | | 40.848 | Kg |
|---|
| 25 | 8.03 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides | | 42.937 | Sqm |
|---|
| 26 | 8.04 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness | | 16.99 | Sqm |
|---|
| 27 | 8.05 | Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including\nnecessary cutting and making goods etc.. Complete | | 7 | Each |
|---|
| 28 | 8.06 | Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc.,\ncomplete.202x42x18 mm weighing not less than 78 gms | | 7 | Each |
|---|
| 29 | 8.07 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Anodized (AC 15 ) aluminium | | 7 | Each |
|---|
| 30 | 8.08 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc.\ncomplete. | | 4 | Each |
|---|
| 31 | 8.09 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary\nbrass screws etc. to suit shutter thickness complete | | 7 | Each |
|---|
| 32 | 9 | PAVER BLOCK | | | |
|---|
| 33 | 9.01 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. | | 99 | Sqm |
|---|
| 34 | 10 | Granite Work | | | |
|---|
| 35 | 10.01 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area\nof slab over 0.50 sqm | | 6 | Sqm |
|---|
| 36 | 11 | Floor Tile | | | |
|---|
| 37 | 11.01 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. | | 144.854 | Sqm |
|---|
| 38 | 11.02 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Dark shade pigment using ordinary cement | | 3.75 | Sqm |
|---|
| 39 | 12 | Painting | | | |
|---|
| 40 | 12.01 | White washing with lime to give an even shade:New work (three or more coats) | | 756.409 | Sqm |
|---|
| 41 | 12.02 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats | | 380.719 | Sqm |
|---|
| 42 | 12.03 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per\nmanufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture | | 28 | Sqm |
|---|
| 43 | 13 | Water Supply & Sanitary Works | | | |
|---|
| 44 | 13.01 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and\nstainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x460 mm bowl depth 200 mm | | 1 | Each |
|---|
| 45 | 13.02 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar tpes with elbow operated levers | | 6 | Each |
|---|
| 46 | 13.03 | Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semi\nrigid pipe32 mm dia | | 6 | Each |
|---|
| 47 | 13.04 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms | | 6 | Each |
|---|
| 48 | 13.05 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This\nincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as per\ndirection of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | | 25 | M |
|---|
| 49 | 14 | Electrical Work | | | |
|---|
| 50 | 14.01 | Point wiring in PVC conduit with modular type switch. | | | |
|---|
| 51 | 14.02 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the\nbox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | | 14 | Point |
|---|
| 52 | 14.03 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type\nmetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP\nswitches and making good the surface of wall, colour washing etc. complete. All the terminations in the\nswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the\nbox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control\nceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | | 10 | Point |
|---|
| 53 | 14.04 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP\nswitches and making good the surface of wall, colour washing etc. complete. All the terminations in the\nswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the\nbox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent\nplug - Short point | | 1 | Point |
|---|
| 54 | 14.05 | Conveyance, installation, testing and commissioning of post-top lantern/ outdoor type FTL/ CFL fittings of\nall types directly on the existing pipe/ pole and giving connections with the existing wiring etc as required | | 2 | Each |
|---|
| 55 | 14.06 | Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting\nbrackets supplied along with the fan. | | 1 | Each |
|---|
| 56 | 15 | SUB MAINS | | | |
|---|
| 57 | 15.01 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated\ncopper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | | 149 | M |
|---|
| 58 | 15.02 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated\ncopper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | | 160 | M |
|---|
| 59 | 15.03 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power\ncable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps\nnot exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with\nfactory made clamp | | 20 | M |
|---|
| 60 | 16 | MODULAR FITTINGS | | | |
|---|
| 61 | 16.01 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box\nincluding connections but excluding modular plate etc. as required.5/6 amps switch | | 11 | Each |
|---|
| 62 | 16.02 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box\nincluding connections but excluding modular plate etc. as required.15/16 amp switch | | 8 | Each |
|---|
| 63 | 16.03 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box\nincluding connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet | | 11 | Each |
|---|
| 64 | 16.04 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box\nincluding connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | | 8 | Each |
|---|
| 65 | 16.05 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular\nswitches in recess etc as required.3 Module (100mmX75mm) | | 1 | Each |
|---|
| 66 | 16.06 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular\nswitches in recess etc as required.6 Module (200mmX75mm) | | 10 | Each |
|---|
| 67 | 17 | POWER CIRCUITRY | | | |
|---|
| 68 | 17.01 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43) | | 1 | Each |
|---|
| 69 | 17.02 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker\nsuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | | 21 | Each |
|---|
| 70 | 17.03 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with\nconnections, testing and commissioning etc. as required.63 amps | | 1 | Each |
|---|
| 71 | 17.04 | SITC 63A RCCB<br>Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>63 amps | | 1 | Each |
|---|
| 72 | 18 | EARTHING | | | |
|---|
| 73 | 18.01 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry\nenclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt\nas required | | 2 | set |
|---|
| 74 | 18.02 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required | | 50 | M |
|---|
| 75 | 19 | ITC Electrical Fittings | | | |
|---|
| 76 | 19.01 | 20W LED TUBE TYPE FIXTURE<br>SITC OF Modular type 20W LED tube type fixture directly on to wall including drilling and fixing, making necessary connections and make as approved by engineer in Charge or Electrical Engineer | | 12 | Each |
|---|
| 77 | 19.02 | Supplying of Ceiling Fan 900mm Sweep complete with 300mm down rod, canopies, shackles and blades and without regulator working on 230/240V Single phase AC,as per latest BEE Standard & IS 374:2019 | | 10 | Each |
|---|
| 78 | 19.03 | WALL FAN<br>Supply and installation of wall fan, white colour, 5 star rated as per BEE complete with\nblades, casing , wall mounting accessories etc(Make Havells/bajaj/usha/V-guard/crompton) | | 1 | Each |
|---|
| 79 | 19.04 | Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than\n105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | | 2 | Each |
|---|