| 1 | 1 | SITC of Oxygen Manifold System of 20 x 20 cylinder bank system for Jumbo Cylinders as per technical specifications. | | 1 | set |
|---|
| 2 | 2 | SITC of Fully Automatic Manifold Control Panel accordance to NFPA99 as per technical specifications. | | 1 | set |
|---|
| 3 | 3 | SITC of Emergency Manifold Header of 10 x 10 cylinder bank system for Jumbo Cylinders as pertechnical specifications. | | 1 | set |
|---|
| 4 | 4 | SITC of Oxygen Flow meter with humidifier bottle CE marked as per technical specifications. | | 1458 | nos. |
|---|
| 5 | 5 | SITC of N2O Manifold System of 10 x 10 cylinder bank system for Jumbo Cylinders as per technical specifications. | | 1 | set |
|---|
| 6 | 6 | SITC of Fully Automatic Manifold Control Panel accordance to NFPA99 as per technical specifications. | | 1 | set |
|---|
| 7 | 7 | SITC of Emergency Manifold Header of 5 x 5 cylinder bank system for Jumbo Cylinders as per tender technical specifications. | | 1 | set |
|---|
| 8 | 8 | SITC of CO2 Manifold System of 10 x 10 cylinder bank system for Jumbo Cylinders as per technical specifications. | | 1 | set |
|---|
| 9 | 9 | SITC of Fully Automatic Manifold Control Panel accordance to NFPA99 as per technical specifications. | | 1 | set |
|---|
| 10 | 10 | SITC of Emergency Manifold Header of 5 x 5 cylinder bank system for Jumbo Cylinders as per technical specifications. | | 1 | set |
|---|
| 11 | 11 | SITC of Medical Air System (Imported) as per technical specifications. \nCompressors configuration should be in Duplex/Triplex/Quadruplex/Pentaplex/Hexaplex. \nPrimary system capacity should deliver 8490 lpm or 300 cfm (+/-5%) and standby provision as per the NFPA99 standard. | | 1 | set |
|---|
| 12 | 12 | SITC of Surgical/Instrument Air system as per technical specifications.\nCompressors configuration should be in Duplex/Triplex/Quadruplex/Pentaplex/Hexaplex. \nPrimary system capacity should deliver 2830 lpm or 100 cfm (+/-5%)and stand by provision as per the NFPA99 standard. | | 1 | set |
|---|
| 13 | 13 | SITC of Medical Vacuum System (Imported) as per tender technical specifications. \nVacuum Pumps configuration should be in Duplex/Triplex/Quadruplex/Pentaplex/Hexaplex. \nPrimary system capacity should deliver 11320 lpm or 400 cfm (+/-5%) and standby provision as per the NFPA99 standard. | | 1 | set |
|---|
| 14 | 14 | SITC of Ward Vacum Unit CE marked as per technical specifications | | 1412 | nos. |
|---|
| 15 | 15 | SITC of Theater Suction Trolley CE marked as per technical specifications | | 46 | nos. |
|---|
| 16 | 16 | SITC of WAGD/AGSS system (Imported) as per tender technical specifications. \nPumps configuration should be in Duplex/Triplex/Quadruplex/Pentaplex/Hexaplex. \nPrimary system capacity should deliver 2800lpm and standby system capacity should be 2800 LPM | | 1 | set |
|---|
| 17 | 17 | SITC of Duplex AGSS Remote Switch | | 23 | nos. |
|---|
| 18 | 18 | SITC AGSS Receiver & Transfer Hose assembly. | | 23 | nos. |
|---|
| 19 | 19 | SITC of AGSS Terminal unit with Probe. | | 23 | nos. |
|---|
| 20 | 20 | SITC of Gas Terminal Units (Imported) for Oxygen as per technical specifications | | 1697 | nos. |
|---|
| 21 | 21 | SITC of Gas Terminal Units (Imported) for Nitorus Oxide as per technical specifications | | 46 | nos. |
|---|
| 22 | 22 | SITC of Gas Terminal Units (Imported) for Medical Air as per technical specifications | | 454 | nos. |
|---|
| 23 | 23 | SITC of Gas Terminal Units (Imported) for Instrument Air as per technical specifications | | 44 | nos. |
|---|
| 24 | 24 | SITC of Gas Terminal Units (Imported) forVacuum as per technical specifications | | 1697 | nos. |
|---|
| 25 | 25 | SITC of Gas Terminal Units (Imported) for CO2 as per technical specifications | | 44 | nos. |
|---|
| 26 | 26 | SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for Oxygen | | 1697 | nos. |
|---|
| 27 | 27 | SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for Nitorus Oxide | | 46 | nos. |
|---|
| 28 | 28 | SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for Medical Air | | 454 | nos. |
|---|
| 29 | 29 | SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for Instrument Air | | 44 | nos. |
|---|
| 30 | 30 | SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box forVacuum | | 1697 | nos. |
|---|
| 31 | 31 | SITC of Compatabile Stainless Steel Probes/Adaters for Gas Outlets & Plastic Mounting Box for CO2 | | 44 | nos. |
|---|
| 32 | 32 | SITC of Imported Touch Screen Medical Gas Alarms for 2 Gas Services as per technical specifications | | 65 | nos. |
|---|
| 33 | 33 | SITC of Imported Touch Screen Medical Gas Alarms for 3 Gas Services as per technical specifications | | 20 | nos. |
|---|
| 34 | 34 | SITC of Imported Touch Screen Medical Gas Alarms for 4 Gas Services as per technical specifications | | 1 | nos. |
|---|
| 35 | 35 | SITC of Imported Touch Screen Medical Gas Alarms for 5 Gas Services as per technical specifications | | 1 | nos. |
|---|
| 36 | 36 | SITC of Imported Touch Screen Medical Gas Alarms for 6 Gas Services as per technical specifications | | 22 | nos. |
|---|
| 37 | 37 | SITCof Imported Zonal Valve Box for 2 Gas Services as per technical specifications. | | 65 | nos. |
|---|
| 38 | 38 | SITCof Imported Zonal Valve Box for 3 Gas Services as per technical specifications. | | 20 | nos. |
|---|
| 39 | 39 | SITCof Imported Zonal Valve Box for 4 Gas Services as per technical specifications. | | 1 | nos. |
|---|
| 40 | 40 | SITCof Imported Zonal Valve Box for 6 Gas Services as per technical specifications. | | 22 | nos. |
|---|
| 41 | 41 | SITC of Imported Line Isolation/Shut off Valves 15mm as per technical specifications. | | 3 | nos. |
|---|
| 42 | 42 | SITC of Imported Line Isolation/Shut off Valves 22mm as per technical specifications. | | 5 | nos. |
|---|
| 43 | 43 | SITC of Imported Line Isolation/Shut off Valves 28mm as per technical specifications. | | 17 | nos. |
|---|
| 44 | 44 | SITC of Imported Line Isolation/Shut off Valves 42mm as per technical specifications. | | 9 | nos. |
|---|
| 45 | 45 | SITC of Imported Line Isolation/Shut off Valves 54mm as per technical specifications. | | 2 | nos. |
|---|
| 46 | 46 | SITC of Imported Line Isolation/Shut off Valves 76mm as per technical specifications. | | 2 | nos. |
|---|
| 47 | 47 | SITC of Imported Line Isolation/Shut off Valves 108mm as per technical specifications. | | 2 | nos. |
|---|
| 48 | 48 | SITC of Horizontal/Vertical Bed Head Panel 1200mm as per technical specifications. | | 280 | set |
|---|
| 49 | 49 | SITC of Horizontal/Vertical Bed Head Panel 1800mm as per technical specifications. | | 205 | set |
|---|
| 50 | 50 | SITC of Copper Pipes with Copper Fitings 108mm dia X 2.0mm thick as per technical specifications. | | 300 | Mtrs |
|---|
| 51 | 51 | SITC of Copper Pipes with Copper Fitings 76mm dia X 1.5mm thick as per technical specifications. | | 250 | Mtrs |
|---|
| 52 | 52 | SITC of Copper Pipes with Copper Fitings 54mm dia X 1.2mm thick as per technical specifications. | | 490 | Mtrs |
|---|
| 53 | 53 | SITC of Copper Pipes with Copper Fitings 42mm dia x 1.0mm thick as per technical specifications. | | 550 | Mtrs |
|---|
| 54 | 54 | SITC of Copper Pipes with Copper Fitings 28mm dia x 1.0mm thick as per technical specifications. | | 1950 | Mtrs |
|---|
| 55 | 55 | SITC of Copper Pipes with Copper Fitings 22mm dia X 1.0mm thick as per technical specifications. | | 11990 | Mtrs |
|---|
| 56 | 56 | SITC of Copper Pipes with Copper Fitings 15mm dia X 1.0mm thick as per technical specifications. | | 17220 | Mtrs |
|---|
| 57 | 57 | SITC of Copper Pipes with Copper Fitings 12mm dia x 1.0mm thick as per technical specifications. | | 7500 | Mtrs |
|---|
| 58 | 58 | SITC of Electrical Control Panel for Vacuum pumps & Air Compressors. \n1.For Medical Air- Modular Compartmentalized floor mounted PMCC with IP 54, Form 3B type having NDO MO FROH 35 kA TPN MCCB 1 no.80 A incomer+4 no. Auto Star minimum 15 kW Delta starter complete with 40 A TP Curve C 10 kA MCB- 32 A Line -32 A Run – 12 A Star AC3 duty contactors- electronic timer- 14-20 A O/L+SPP relay- A/M & L/R switch-R/G/A lamps-R/G/B pushbuttons etc.\n \n2.For Medical Vacuum- Modular Compartmentalized floor mounted PMCC with IP 54, Form 3B type having NDO MO FROH 35 kA TPN MCCB 1 no.80 A incomer+4 no. Auto Star minimum 7.5 kW Delta starter complete with 25 A TP Curve C 10 kA MCB- 25 A Line -25 A Run – 12 A Star AC3 duty contactors- electronic timer- 7.5-10 A O/L+SPP relay- A/M & L/R switch-R/G/A lamps-R/G/B pushbuttons etc. | | 1 | Job |
|---|
| 59 | 59 | SITC of Oxygen Generator Plant minimum 1150 LPM capacity @ 93% +/-3 % purity as per tender technical specifications with Oil Lubricated Screw Compressor, Refrigerant Dryer, Air Receiver, Oxygen Generator, Oxygen Receiver, Integrated LCD Graphic Controller Oxygen Generator system , Oxygen Sensor, Inlet PDP Senor, Flow Meter, Safety Purge Control mechanism, Outlet Pressure Regulator, Filter., Automatic Manifold Control Panel.\n | | 1 | set |
|---|
| 60 | 60 | SITC of Liquid Oxygen Tank of 20KL + 10KL with vaporiser having Capacity : Minimum 20000 ltrs water capacity- 1 No and Minimum 10000 litres water capacity – 1No Design Code : ASME Sec.VIII Div.I Latest Edition/EN 13458-2 Annexure –C/AD2000 MARKBLATTER 2004 Edition Max working pressure : 17 Bar G, Design temperature : - 196°C to + 50°C, Hydraulic test pressure : 26 bar G, Type of Insulation : Vacuum, Perlite filled, Safety Valve Set pressure : 17 Bar G (dual safety valve with three way diverter valve), Bursting Disc Set pressure : 23 Bar G (Bursting disc)\n | | 1 | set |
|---|
| 61 | 61 | SITC of VDE 0834 certified/ approved System Switch:PM\nThe system switch forms a decentralised communications node for exchanging data between the connected system devices and the rest of the communications system, consisting of : \n- 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX), galvanically isolated conforming to EN 60950 and VDE 0834;\n- 7 x RJ45 sockets, each for a 100Mb IP system port (IEEE802.3 100BaseTX) for connecting all IP capable system modules;\n- 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX) for connecting communications, staff and ward terminals as well as control panel PCs or for redundant Connection. \n- Control LEDs for indicating the current operating state;\n- 2 x RJ45 sockets for connection of the external data bus;\n- All IP system modules are supplied with power using Power over LAN technology;\n- In case of Failure of System switch Not more then 20 Rooms or 30 beds should be affected. \n\n | | 70 | Nos |
|---|
| 62 | 62 | SITC of VDE 0834 certified/ approved VOIP based Nurse Station with inbuilt SIP Phone:\nVOIP Based Nurse Station shall comprises of minimum 6“ large touch screen LC colour graphic display for displaying all details , inbuilt SIP Phone, a smash proof glass panel (to protect the sensitive display from unnecessary contact during cleaning and other processes) , Querying receiver for speaking discretely, Microphone and loudspeaker for hands-free speech (incl. volume control), automatic changeover between hands-free and discrete speaking , Electronic circuit board with controller and FlashProm, 100BaseTX interface to the system switch, PC interface to the communications control panel , 2.8m connection cable with an RJ45 connection plug, which is protected, from disconnection, for connecting to a connection module . The ward terminal shall display date and time, indication of all presence, all set reminedrs, indication of all calls in accordance with VDE0834. All call indications follow the priority and must display the exact location of the calls. The ward terminal shall be provided along with suitable connection module & back box | | 76 | Nos. |
|---|
| 63 | 63 | SITC of VDE 0834 certified/ approved Patient Handset - Without Speech\nconsisting of a plastic case in antimicrobial finish having\n- Call button with nurse symbol with integrated finder and reassurance light on the top end of the unit,\n- Membrane keypad in antimicrobial finish with integrated LEDS for operation, consisting of:\n - 1 call key,\n - 2 lighting keys\n- 2.80 metre connection cable with auto-disconnecting RJ45 connector plug.\nIt shall be supplied with cradel for holding patient terminals. | | 1336 | Nos. |
|---|
| 64 | 64 | SITC of VDE 0834 certified/ approved connection module for Patient Terminal\nConnection module for patient handset shall consist of: with anti microbial coating\n- 1 x RJ45 socket marked in colour and with measures to ensure that the push button is correctly connected, including auto disconnect mechanism,\n- 1 membrane keypad with:\n - 1 call button (red with nurse symbol) including a finder/reassurance light,\n - 1 presence key cum cancel button (green) including a control LED, \n - 1 DIN port for co connecting Medical Divces | | 1336 | Nos. |
|---|
| 65 | 65 | SITC of module providing DVI output\nModule to provide DVI output to connect with any 3rd party LCD/LED monitor to display nurse call notification on external LED/LCD screen. (Note: LCD/ LED screen to be provided by client) | | 76 | No. |
|---|
| 66 | 66 | External LED Monitor for displaying Nurse Call status \nMinimum 20\" LED wall/ ceiling mounted screen having DVI input port. Make: Benq, HP, LG, Samsung | | 76 | Nos. |
|---|
| 67 | 67 | SITC of VDE 0834 certified/ approved Code Blue Call \n - Antimicrobial Membrane keypad with 1 Code Blue Call button incl. finder . reassurance light and 1 doctor presence button (blue) incl. control LED,\n- Integrated piezo buzzer - Incl. an installation frame for screw-free attachment with countersunk backbox | | 359 | Nos. |
|---|
| 68 | 68 | Supply of VDE 0834 certified/ approved Pull Cord \nSITC OF VDE 0834 complied Pull cord shall consist of : \n- Integrated finder / reassurance light\n- Microswitch with 2 metre pull cord\n-- Incl. an installation frame for screw-free attachment with countersunk backbox | | 365 | Nos. |
|---|
| 69 | 69 | Supply of VDE 0834 certified/ approved Lamp Module\nFor optical indication of calls, presences and reminders in the relevant colours conforming to VDE0834 consisting of:\n- 4 light chambers with light reflectors for homogeneous illumination,\n- 1 light chamber fitted with 3 ultra bright red LEDs,\n- 1 light chamber fitted with 3 ultra bright white LEDs,\n- 1 light chamber fitted with 3 ultra bright green LEDs,\n- 1 light chamber fitted with 3 ultra bright blue LEDs,\n- the LED life expectancy is approximately 100,000 operating hours, | | 359 | Nos. |
|---|
| 70 | 70 | SITC of Supply of Management center - Nurse Call Server\nManagement Centre Server for Nurse Call System for uploading the firmware and the system configuration, for operating interfaces to foreign systems, for logging of all system events and as a central location for system configuration and remote maintenance as per VDE 0834 - Intel Xeon 3220 2,4GHz or similar\n- 2 GB RAM, 1 x 160GB HDD\n- 1 x DVD harddrive, 2 x Gbit LAN Ethernet RJ45\n- 1 x serial connection RS232 and 2 x USBV2.0\n- 1 x PCI or 1 x PICe socket, support for SUSE Linux enterprise Server from V10.1\n- The system working on any Virtual Plateform (VM Ware / Virtual Box / Hyper V etc) is striclty not allowed | | 1 | No. |
|---|
| 71 | 71 | SITC of Backbone Switch \nFloor Switch: \nUplink connections: 2 x 1Gb uplink ports, RJ45 (GBIC capable, possibility for LWL) Connections downlink: 24 x 100Mb downlink ports, RJ45 Switch must have all the Layer 2 and Layer 3 function which is mentioned in the tender Document | | 3 | No. |
|---|
| 72 | 72 | SITC of Server Switch \nUplink connections: 4 x 10 Gb uplink ports, RJ45 or SFP (dual share ports) Optional: via GBIC usage FOC with 4 x 10 GB SFP (small form-factor plugable) Downlink connections: 20 x 1 Gb downlink ports, RJ45 | | 1 | No. |
|---|
| 73 | 73 | SITC of Software- Event Database Software\nSoftware pack installed on the system server for automatically logging all events\nin the entire communications system, such as, e.g., calls, presence markings,\ncall acknowledgements, reminders. All the report should be able to generate on real time basis without any delay. The Licesce should be for life time without any additional cost in future. | | 1 | No. |
|---|
| 74 | 74 | SITC of Central Monitoring S/w for monitoring all the nurse station calls at central location with GUI option With Latest Config PC + Monitor | | 1 | Nos. |
|---|
| 75 | 75 | SITC of Software to forward the important Events to Hospital Staff over SMS , it should have facility to send SMS based on Type of events or calls | | 1 | Nos. |
|---|
| 76 | 76 | Supplying and erecting SMPS with input voltage 230 V A.C. & output voltage 24 V DC, charging current 7 A suitablewith necessary connecting wires. | | 70 | Nos. |
|---|
| 77 | 77 | Suppying, Installation, Testing & Commissioning of Front Loading - NW 160; Carrier support rack NW 160, for 5 carriers; Receiving set OVS NW 160; Lower tube end NW 160 - Saturn station; Upper tube end NW 160 - Saturn station with built in LCD Display showing TIme Date, Destination, last carrier arrived from position, fault indication etc. , with wipeable membrane keypad. The stations should be manufactured from hygienic closed cell materials with smoked acrylic door for front loading. THe station should have mounting arrangement at any desired height. | | 29 | Nos |
|---|
| 78 | 78 | Supplyinf, Installation, Testing & Commissioning of Laboratory 3rd Generation Auto-Unloading stations size NW 160 with DUAL channel connection, pushing plunger capable to handle large amount of carrier with sensitive content with features such as Soft Arrivial, fast rejection, RFID detection, Auto Homing with easy maintenance. | | 1 | NO |
|---|
| 79 | 79 | Supplying, Installation, Testing & Commisioning of Stations accessories - Receiving Cabinet / Carrier rack etc etc | | 29 | Nos |
|---|
| 80 | 80 | Supply, Installation, Testing & Commisioning of Microprocessor based Central Control Unit, with Intel 16 bit processor having ROM loaaded Software capable to operate all station through SELV. with analysis the system day to day operations having real time monitoring and lithium ion battery to store operational data in event of power failure. The system should having 2 Nos. of RS232 ports.THe system should show fault status, location of faulty station with alarm report generation feature. | | 1 | No |
|---|
| 81 | 81 | Supplying, Installtion , Testing & Commission additional Power Supply for Voltage regulation having 115/230 Volt AC-input, 1 x 42 Volt DC-output, 4 A with short-circuit-proof with electronic fuse having IP 40 protection.\n | | 5 | Nos |
|---|
| 82 | 82 | Supplying, Installation, Testing and Commissioing of 6 Way Diverter with Sealed with maintenance-free Teflon-bushings.Reliable industrial grade motor with overcurrent- release, radio-screened. Indication and as a standard connection for monitoring device and remote operation. Solid aluminium frame with heavy duty plastic covers having provision to be installed in many positions with Diverter drive mechanism is direct gear driven capable of moving carriers from one tube to another within the system with a minimum of shock, noise and vibration with Self-controlling and self-positioning mechanism that prevents the diverter to jam or lock.\n | | 4 | Nos |
|---|
| 83 | 83 | Supplying, Installation, Testing and Commissioing of 3 Way Diverter with Sealed with maintenance-free Teflon-bushings.Reliable industrial grade motor with overcurrent- release, radio-screened. Indication and as a standard connection for monitoring device and remote operation. Solid aluminium frame with heavy duty plastic covers having provision to be installed in many positions with Diverter drive mechanism is direct gear driven capable of moving carriers from one tube to another within the system with a minimum of shock, noise and vibration with Self-controlling and self-positioning mechanism that prevents the diverter to jam or lock.\n | | 3 | Nos |
|---|
| 84 | 84 | Supplying, Installation, Testing & Commissioning of Three-phase-blower having minimum capacity of 500 cu.m/ hr, 4.6kW for air-supply of the system to achieve transport speed of at least 6 m/sec having Connecting-socket for fresh-air-suction included with 2 nos. of silencers. | | 4 | Nos |
|---|
| 85 | 85 | Supplying, Erection, Testing & Commissioning of 5 zone linear coupler combined with high send frequencies and many stations. It couples multiple lines which enables to make more efficient use of the system capable of handling minimum 500 carrier per hour. | | 1 | Nos |
|---|
| 86 | 86 | Supplying, Erection, Testing & Commissioning of Dispatch Tube NW 160mm made of Weather-proof,Wear-resistant, Sound absorbing, Hard-PVC-U according to class B1 with Special surface treatment for polished inside and outside wall with accessories such as fastening tube clamps, cable strips etc. complete.\n | | 500 | Mtr |
|---|
| 87 | 87 | Supplying, Erection, Testing & Commissioning of dispatch tube Bend NW 160 with Radius of 800mm made of Weather-proof,Wear-resistant, Sound absorbing, Hard-PVC-U according to class B1 with Special surface treatment for polished inside and outside wall with accessories such as fastening tube clamps, cable strips etc. complete.\n | | 180 | Nos |
|---|
| 88 | 88 | Supplying, Erection, Testing & Commissioning of UPVC Sleeves NW160mm fixing the tube joints, diverters etc. to the tube run made of Weather-proof,Wear-resistant, Sound absorbing, Hard-PVC-U according to class B1 with Special surface treatment for polished inside and outside wall with accessories such as fastening tube clamps, cable strips etc. complete. | | 450 | Nos |
|---|
| 89 | 89 | Supply & Erection of SS clamps for Hanging/clamping the tube | | 700 | Nos |
|---|
| 90 | 90 | Supply & Installation of 1.5 sq.mm 6 core shielded, twisted & paired FRLSH cable for power, data & grounding for interconnecting central control station and receiving stations. | | 900 | Mtr |
|---|
| 91 | 91 | Supplying Carrier for sample transportation of Size 160mm having Robust / tough design with Payload max.: 6 kg with 1/2 x swivel cap compatable to use in tube with radius = R800 bends. | | 160 | Nos |
|---|
| 92 | 92 | Supplying Leakeproof Carriers of size 160mm For sensitive samples for examples – Urine with Self-closing with clip, soft cap on both sides to protect the samples having Identification Chip for Carriers (Transponder) | | 10 | Nos |
|---|