| 1 | 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sqm on plan area and not exceeding 1.5m deep in hard/ dense soil complete all as specified and as directed. | | 862 | CUM |
|---|
| 2 | 2 | Returning filling in excavated soil including spreading levelling and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. | | 196 | CUM |
|---|
| 3 | 3 | Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed. | | 666 | CUM |
|---|
| 4 | 4 | Material and labour for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping of poles including demolition of old concrete, form work etc, complete all as specified & directed. | | 7 | CUM |
|---|
| 5 | 5 | Supply and spread river washed sand free from foreign material in trenches for UG cable cushioning including necessary consolidation as required complete all as specified and directed.\nNote:- For payment purpose only punned thickness of sand will be measured and paid. | | 49 | CUM |
|---|
| 6 | 6 | Material and labour for Galvanised steel tubing, light grade laid in trenches/ fixed to poles, walls etc as a protection for service cable including removing existing old unserviceable rusted pipe complete all as specified and directed for the following size of pipe:- | | | |
|---|
| 7 | 6.01 | 40 mm dia bore. | | 12 | RM |
|---|
| 8 | 6.02 | 50 mm dia bore\nNotes for Item No 6.01 to 6.02:- \n(i) The minor parts such as clamps, screw etc.,, required for fixing pipe on wall, pole, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate. | | 12 | RM |
|---|
| 9 | 7 | Supplying and laying 50mm Outer Dia (DWC) HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. confirming to IS 14930, Part II complete with fitting and cutting, joining etc. direct in ground (i.e., below ground level) as a cable protection complete all as specified and directed. | | 6570 | RM |
|---|
| 10 | 8 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm all as specified and as directed. | | 4000 | Each |
|---|
| 11 | 9 | Supplying, laying in trenches, passing through pipe, heavy duty FRLS Copper wire of size 2 core, 10 Sq.mm, PVC Insulated, Unsheathed, Copper Multistranded Conductor, 1100 Volts Grade, ISI marked, drawing through DWC pipe including testing complete all as specified and directed. \nNote: \n(i) Earth work excavation/ Provn DWC pipes shall be measured and paid separately.\n | | 13140 | RM |
|---|
| 12 | 10 | Supplying, laying and commissioning of LT XLPE cables, insulated, screened, PVC bedded, galvanized steel strip armoured, earthed, electric power cable with Aluminium conductor, 1100 Volts grade, for the following of cross sectional area laid in trenches/ fixed on poles including taking out old UG cable complete all as specified and directed. \nNote: Earth work excavation shall be measured and paid separately. | | | |
|---|
| 13 | 10.01 | 10 Sq mm, 2 core | | 200 | RM |
|---|
| 14 | 10.02 | 16 Sq mm, 4 core | | 450 | RM |
|---|
| 15 | 11 | Material & Labour for MS LT cable route marker embedded on PCC block having size 300 X 300 X 600 mm nominal mix type B1(1:2:4) including earth work, formwork complete all as specified and directed. | | 20 | EACH |
|---|
| 16 | 12 | Material and labour for plate earthing with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including 4mm dia GI earth wire bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipment’s etc at the other end including 15 mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate and 40mm thick; RCC cover in 1:2:4 type B-1 reinforced with 8mm dia TMT @ 75 c/c both ways complete all specified and shown in electrical plate No 3 of SSR Part-1 including testing earth resistance and submitting test report to AGE E/M by the contractor complete all as specified & directed.\nNote :- \n(i) Earthing resistance required in earthing shall less than 1.0 Ohms after completion of work. All earthing shall be tested by the contractor in presence of Engr-in-Charge. Test result shall be recorded and signed by the contractor and Engr – in- Charge. If contractor fail to achieve the above result the same shall be rectified by the contractor without any extra cost to Govt. The earthing result will be required maintaining up to end of defect liability period of one year and if any variation found in earthing result during defect liability period same will be intimated to the contractor by Engg-in-Charge and contractor shall rectify the same. The quoted rates shall be deemed to include for above said provision.\n(ii) Quoted rates shall be deemed to be included for earth wire with protection pipe up to 7.5 length.\n | | 6 | EACH |
|---|
| 17 | 13 | Material and labour for cutting of Road/ Hard standing not less than 30 cm in depth and 15 cm width including making good the same with PCC 1:2:4, type B1 using 20 mm graded stone aggregate complete all as specified and directed. | | 10 | RM |
|---|
| 18 | 14 | Material and labour for horizontal bore size up to 150 mm bore and length n exc 12 mtr long of road and n exc 1.2 mtr below of the road / PCC path way / PCC hard standing for passing of cable protection GI pipe complete all as specified & directed . | | 15 | RM |
|---|
| 19 | 15 | Supply and fix in repairs street light fitting; 30 Watt LED made up of pressure die cast luminaire comprising of epoxy powder coated housing with toughened glass frame and high-power LEDs with option of secondary optic with IP 65 protection and efficacy 110LM/W including taking down old fittings complete all as specified and directed. | | 55 | Each |
|---|
| 20 | 16 | Supply and fix in repairs street light fitting; 45 Watt LED made up of pressure die cast luminaire comprising of epoxy powder coated housing with toughened glass frame and high-power LEDs with option of secondary optic with IP 65 protection and efficacy 110LM/W including taking down old fittings complete all as specified and directed. | | 55 | Each |
|---|
| 21 | 17 | Supply and fix in repairs street light fitting; 60 Watt LED made up of pressure die cast luminaire comprising of epoxy powder coated dark graphite grey colour finish housing with toughened glass frame and high-power LEDs with IP 66 protection including taking down old fittings complete all as specified and directed. | | 20 | Each |
|---|
| 22 | 18 | Material and labour for taking down old aluminium conductor of two run from existing electric poles of any height complete all as specified and directed.\nNote: Two runs of aluminium conductor shall be measured as one single unit.\n | | 1000 | RM |
|---|
| 23 | 19 | Supply only bamboo ladder of superior quality 20 feet long as per sample available at AGE E/M office. | | 1 | Each |
|---|
| 24 | 20 | Supply only bamboo ladder of superior quality 25 feet long as per sample available at AGE E/M office. | | 1 | Each |
|---|
| 25 | 21 | Supply and fix in repair junction box IP 65 with metric knockouts for cable entry up to 25 Sq mm, Box size 200 x 160 x 98 mm minimum with terminals and synthetic glands including 01 no of MCB SP 6 Amp and fixed on pole/ wall with MS clamps including two coat of Aluminum paint over one coat of red oxide primer complete all as specified and directed. | | 54 | Each |
|---|
| 26 | 22 | Supply and fix Junction box IP 65 with metric knockouts for cable entry up to 25 Sq mm, Box size 200 x 160 x 98 mm minimum with terminals and synthetic glands; fixed on wall with necessary screws including two coat of Aluminium paint over one coat of red oxide primer complete all as specified and directed. | | 22 | Each |
|---|
| 27 | 23 | Supply and fix junction box IP 65 with metric knockouts for cable entry up to 50 Sq mm, Box size 210 x 310 x 116 mm minimum with 04 terminals; fixed on wall with necessary screws including two coat of Aluminium paint over one coat of red oxide primer complete all as specified and directed. | | 22 | Each |
|---|
| 28 | 24 | Supply and fix in repair GI pipe bracket bent to shape drilled welded made out of 32 mm dia bore light grade GI Pipe 1.2 metre long for fixing of street light fitting of any type and description including suitable size of MS clamps, nuts, bolts & washers including two coat of Aluminium paint over one coat of red oxide primer complete all as specified and directed. | | 50 | EACH |
|---|
| 29 | 25 | Supply and fix in repair GI pipe bracket bent to shape drilled welded made out of 40 mm dia bore light grade GI Pipe 1.2 metre long for fixing of street light fitting of any type and description including suitable size of MS clamps, nuts, bolts & washers including two coat of Aluminium paint over one coat of red oxide primer complete all as specified and directed. | | 60 | EACH |
|---|
| 30 | 26 | Supply and testing on load cable fault locator Model No 1200 J – thumper inbuilt auto discharge and totally earth protected safety interlock, in built discharge, timer, Zero indicator, Earth protection, Machine working hour counter Accessories; Mains cord, Earth Cord, HV cable 20 metre (New body design) including pulse receiver 20 X 4 LCD display, Acoustic magnetic dual channel having noise cancelling option to find correct cable route (New body design) complete all as specified and directed. | | 1 | Each |
|---|
| 31 | 27 | Supply and testing on load HV tester rating 50 KV DC inbuilt auto discharge and totally earth protected safety interlock, on built discharge, Timer, zero indicator, Earth protection, Machine working hour counter accessories mains cord complete all as specified and as directed. | | 1 | Each |
|---|
| 32 | 28 | Supply and testing Earth resistance tester 0 to 2000 Ohm complete with 4 spikes 4 test leads, charging lead and carrying case complete all as specified and directed. | | 2 | Each |
|---|
| 33 | 29 | Supply and testing AC/ DC digital clamp meter, 1000A DC/ 800A AC, battery operated, LED display complete all as specified and directed. | | 3 | Each |
|---|
| 34 | 30 | Supply and testing Digital multimeter AC/ DC, battery operated, LED display complete. | | 1 | Each |
|---|
| 35 | 31 | Note:- (i) The amount against Schedule of Credit mentioned in tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contarct Sum for Acceptance. | | | |
|---|