Repair Replacement Of External Water Supply Pipe Lines Ci Di Ms Gi Of Various Sizes Cleaning Of Semi Underground Sump Rcc Overhead Tanks Of Different Capacities And Connected Works At Bhalra Mil Stn Under Ge ( I ) 873 Ews Repair Replacement Of External , BHADERWAH-Jammu And Kashmir

Military Engineer Services-MES has published Repair Replacement Of External Water Supply Pipe Lines Ci Di Ms Gi Of Various Sizes Cleaning Of Semi Underground Sump Rcc Overhead Tanks Of Different Capacities And Connected Works At Bhalra Mil Stn Under Ge ( I ) 873 Ews Repair Replacement Of External . Submission Date for this Tender is 14-10-2020. Pipe Laying Tenders in BHADERWAH Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

25629801
Repair Replacement Of External Water Supply Pipe Lines Ci Di Ms Gi Of Various Sizes Cleaning Of Semi Underground Sump Rcc Overhead Tanks Of Different Capacities And Connected Works At Bhalra Mil Stn Under Ge ( I ) 873 Ews Repair Replacement Of External
Open Tender
Indian
Jammu And Kashmir
BHADERWAH
14-10-2020

Tender Details

Repair Replacement Of External Water Supply Pipe Lines Ci Di Ms Gi Of Various Sizes Cleaning Of Semi Underground Sump Rcc Overhead Tanks Of Different Capacities And Connected Works At Bhalra Mil Stn Under Ge ( I ) 873 Ews Repair Replacement Of External Water Supply Pipe Lines Ci Di Ms Gi Of Various Sizes Cleaning Of Semi Underground Sump Rcc Overhead Tanks Of Different Capacities And Connected Works At Bhalra Mil Stn Under Ge ( I ) 873 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 46000.0 /-
Tender Value
INR 23 Lakhs /-

BOQ Items

Name of Work : REPAIR / REPLACEMENT OF EXTERNAL WATER SUPPLY PIPE LINES CI/ DI/ MS/GI OF VARIOUS SIZES, CLEANING OF SEMI UNDERGROUND SUMP & RCC OVERHEAD TANKS OF DIFFERENT CAPACITIES AND CONNECTED WORKS AT BHALRA MIL STN UNDER GE (I) 873 EWS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavating in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out, complete all as specified and as directed. 95 Cubic Metre
2 2 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. 85 Cubic Metre
3 3 Removing excavated soils not exceeding 50 metres and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed. 10 Cubic Metre
4 4 Demolition of cement concrete (un-reinforced) of any descrition and in any position not otherwise specifically provided for, complete all as specified and directed. 8 Cubic Metre
5 5 Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling, basement and mass concrete for bends, pipe support, complete all as specified and directed. 8 Cubic Metre
6 6 Taking out Mild Steel / Cast Iron / Ductile Iron / Galvanised Iron water mains including all fittings with spigot and socket ends or flanged ends including lead / tyton joints and burning out lead joints and recovering lead, cleaning the pipe and removing to store for reuse complete all as specified and as directed :-\nNote : Excavation and earth work shall be measured and paid separately.\n
7 6.01 (a) 400 mm bore 17 Running Meter
8 6.02 (b) 200 mm bore 72 Running Meter
9 6.03 (c) 150 mm bore 72 Running Meter
10 6.04 (d) 100 mm bore 33 Running Meter
11 6.05 (e) 80 mm bore 33 Running Meter
12 7 Taking out old unserviceable Galvanised Iron Water Pipe (including all fittings) from walls / floors / ceilings / trenches complete of following sizes :-\n
13 7.01 (a) 50 mm bore 60 Running Meter
14 7.02 (b) 40 mm bore 60 Running Meter
15 7.03 (c) 25 mm bore 72 Running Meter
16 7.04 (d) 20 mm bore 72 Running Meter
17 7.05 (e) 15 mm bore 36 Running Meter
18 8 Laying only in trenches serviceable MS / CI / DI pipe / GI pipes after through cleaning / srubbing internally and externally, removal of blockage if any and welding for stopping leakages, if any, of the following description all as specified and as directed.\nNotes : \n1. Joints and fittings / specials will be measured and paid seperately under relevant item of Schedule.
19 8.01 (a) 400 mm bore 11 Running Meter
20 8.02 (b) 200 mm bore 22 Running Meter
21 8.03 (c) 150 mm bore 22 Running Meter
22 8.04 (d) 100 mm bore 11 Running Meter
23 8.05 (e) 80 mm bore 11 Running Meter
24 9 Re-routing / relaying of serviceable GI pipe line obtained from Serial Item No 7.00 after through cleaning / scrubbing internally and externally of the following size, all as directed.\nNotes :\n(i) Excavation will be measured and paid seperately under relevant item of Schedule.\n(ii) Fittings such as sockets, union, Tee, bends, elbow required are demeed to be included in unit rate.\n
25 9.01 (a) 50 mm bore 12 Running Meter
26 9.02 (b) 40 mm bore 12 Running Meter
27 9.03 (c) 25 mm bore 12 Running Meter
28 9.04 (d) 20 mm bore 12 Running Meter
29 9.05 (e) 15 mm bore 12 Running Meter
30 10 Supply, laying, jointing and testing Mild steel ERW pipes having minimum 5.4 mm wall thickness confirming to IS : 1239-2004 amended upto date in any length of following description, complete all as pecified and as directed. \nMake : TATA / Jindal / Prakash / Swastik
31 10.01 (a) 400 mm bore 6 Running Meter
32 10.02 (b) 200 mm bore 6 Running Meter
33 10.03 (c) 150 mm bore 6 Running Meter
34 11 Supply, laying, jointing and testing Cast Iron Pipes with spigot and socket ends centrifugally cast, class ‘LA’, in any length, laid in trenches of the following bore :-\nNote : Run lead joints / tyton joints, CI specials and earth work shall be measured and paid separately.\nMake : Electro Steel / Lanco / Kesoram / Tata Metaliks / Electrotherm.
35 11.01 (a) 200 mm bore 22 Running Meter
36 11.02 (b) 150 mm bore 22 Running Meter
37 11.03 (b) 100 mm bore 11 Running Meter
38 11.04 (b) 80 mm bore 11 Running Meter
39 12 Supply, laying, jointing and testing Ductile iron pipe with spigot and socket ends Class K-7 suitable for tyton joint including jointing material/joints laid in trenches complete all as specified and directed of following sizes:-
40 12.01 (a) 200 mm bore 22 Running Meter
41 12.02 (b) 150 mm bore 22 Running Meter
42 12.03 (b) 100 mm bore 11 Running Meter
43 12.04 (b) 80 mm bore 11 Running Meter
44 13 Supply and fixing pipe galvanised medium grade with all fittings such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc. supplied and laid in trenches complete including all fittings of following sizes :-\nMake : Jindal / TATA / Prakash Tubes
45 13.01 (a) 50 mm bore 48 Running Meter
46 13.02 (b) 40 mm bore 48 Running Meter
47 13.03 (c) 25 mm bore 60 Running Meter
48 13.04 (d) 20 mm bore 60 Running Meter
49 13.05 (e) 15 mm bore 24 Running Meter
50 14 Cutting the CI/ DI pipes and reducing the required length before laying for inserting of new CI specials such as Tees/ reducers/ tail pieces/ collars/ sluice valve/ air release valve etc. complete for following sizes of pipes:-\nNote:- CI specials and earth work will be measured and paid seperately.
51 14.01 (a) 200 mm bore 6 Each \nJob\n
52 14.02 (b) 150 mm bore 6 Each \nJob\n
53 14.03 (c) 100 mm bore 4 Each \nJob\n
54 14.04 (d) 80 mm bore 4 Each \nJob\n
55 15 Specials of Ductile iron / Cast Iron fittings for spigot and socket / flanged pipe upto 150mm bore such as bends (any type radius and angle) tapers any type (straight, bends) tee, joint piece single branch, Y junction, double branch, cross (all socket or socket and spigot or all flanged ends) collar, caps and plug, connecting piece one end flanged and other socketed or spigot and bell mouth complete all as specified and as directed. \nNote : \n1. The fittings shall be as per IS1538-1989\n2. The joints shall be measured and paid separately. 800 Kilogram
56 16 Specials of Ductile iron / Cast Iron fittings for spigot and socket / flanged pipe 200mm to 400mm bore such as bends (any type radius and angle) tapers any type (straight, bends) tee, joint piece single branch, Y junction, double branch, cross (all socket or socket and spigot or all flanged ends) collar, caps and plug, connecting piece one end flanged and other socketed or spigot and bell mouth complete all as specified and as directed. \nNote : \n1. The fittings shall be as per IS1538-1989\n2. The joints shall be measured and paid separately. 600 Kilogram
57 17 Taking out/ brning out of leakin and damaged lead joints of existing CI mainsfrom position including removing the old lead carefully without damaging to the pipe complete for the fllowing bore of pipes:\nNote: Excavation and earth work will be measured and paid seperatly.
58 17.01 (a) 200 mm bore 12 Each \nJob\n
59 17.02 (b) 150 mm bore 12 Each \nJob\n
60 17.03 (c) 100 mm bore 6 Each \nJob\n
61 17.04 (d) 80 mm bore 6 Each \nJob\n
62 18 Run lead joints for CI pipe, spigot and socket ends including jointing materials such as spun yarn etc. complete for CI pipe of following description all as specified and directed.
63 18.01 (a) 200 mm bore 12 Each
64 18.02 (b) 150 mm bore 12 Each
65 18.03 (c) 100 mm bore 6 Each
66 18.04 (d) 80 mm bore 6 Each
67 19 Welding joints for CI / DI / MS pipes including jointing material such as welding rods etc. complete for pipe of following description all as specified and directed.\nNote : The contractor shall make his own arrangement for Welding Machine and DG set required for welding work and nothing extra from the department shall be admisible on this account.
68 19.01 (a) 400 mm bore 4 Running Meter
69 19.02 (b) 300 mm bore 2 Running Meter
70 19.03 (c) 200 mm bore 8 Running Meter
71 19.04 (d) 150 mm bore 8 Running Meter
72 19.05 (e) 100 mm bore 6 Running Meter
73 19.06 (f) 80 mm bore 4 Running Meter
74 20 Cast Iron Sluice Valve class PN-1, PD short body conforming to IS:14846-2000, heavy duty, both ends flanged with stainless steel spindle & check nut, CI operating wheel, all nuts, bolts, washers, gaskets etc. of the following description, including dismantling of old unserviceable Sluice Valve, complete all as specified & directed.
75 20.01 (a) 400 mm bore 1 Each
76 20.02 (b) 200 mm bore 1 Each
77 20.03 (c) 150 mm bore 1 Each
78 20.04 (d) 100 mm bore 1 Each
79 20.05 (e) 80 mm bore 1 Each
80 21 Stainless Steel (SS) Sluice Valve class PN-1, PD short body conforming to IS:14846-2000, heavy duty, both ends flanged with stainless steel spindle & check nut, operating wheel, all nuts, bolts, washers, gaskets etc. of following description, including dismantling of old unserviceable Sluice Valve, complete all as specified & directed.
81 21.01 (a) 200 mm bore 2 Each
82 21.02 (b) 150 mm bore 2 Each
83 22 Cast Iron Non Return Valve without by-pass arrangement, swing type, confirming to IS:5312, flanged ends, all nuts, bolts, washers, gaskets etc. of following description, including dismantling of old unserviceable NRV, complete all as specified and directed.
84 22.01 (a) 400 mm bore 1 Each
85 22.02 (b) 200 mm bore 1 Each
86 22.03 (c) 150 mm bore 1 Each
87 23 Stainless Steel (SS) Non Return Valve without by-pass arrangement, swing type, confirming to IS:5312, flanged ends, all nuts, bolts, washers, gaskets etc. of following description, including dismantling of old unserviceable NRV, complete all as specified and directed.
88 23.01 (a) 300 mm bore 1 Each
89 23.02 (b) 200 mm bore 2 Each
90 23.03 (c) 150 mm bore 2 Each
91 24 Air release valve with double chamber of bore conforming to IS 14845 of following description, including dismantling of old unserviceable NRV, complete all as specified and directed.
92 24.01 (a) 100 mm bore 2 Each
93 24.02 (b) 80 mm bore 3 Each
94 24.03 (c) 50 mm bore 4 Each
95 25 Supply and fixing Gun metal globe / gate valve ISI Marked with and including jointing meterial and taking out old unserviceable valves complete all as specified and directed of following sizes :- \nMake : Advance / Bir / Leader / Sant
96 25.01 (a) 50 mm bore 8 Each
97 25.02 (b) 40 mm bore 10 Each
98 25.03 (c) 25 mm bore 12 Each
99 25.04 (d) 20 mm bore 12 Each
100 25.05 (e) 15 mm bore 6 Each
101 26 Stop valves of cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete of the following description including taking out the old unserviceable stop valve complete all as specified and directed.\n
102 26.01 (a) 50 mm bore 8 Each
103 26.02 (b) 40 mm bore 10 Each
104 26.03 (c) 25 mm bore 12 Each
105 26.04 (d) 20 mm bore 12 Each
106 26.05 (e) 15 mm bore 6 Each
107 27 Supply and fixing GI Socekt of Havey grade with and including jointing meterial and taking out old unserviceable socket complete all as specified and directed of following sizes :- \nMake : Make : Jindal / TATA / Prakash Tubes
108 27.01 (a) 50 mm bore 10 Each
109 27.02 (b) 40 mm bore 10 Each
110 27.03 (c) 25 mm bore 12 Each
111 27.04 (d) 20 mm bore 12 Each
112 27.05 (e) 15 mm bore 10 Each
113 28 Supply and fixing GI Union of Havey grade with and including jointing meterial and taking out old unserviceable Union complete all as specified and directed of following sizes :- \nMake : Make : Jindal / TATA / Prakash Tubes
114 28.01 (a) 50 mm bore 10 Each
115 28.02 (b) 40 mm bore 10 Each
116 28.03 (c) 25 mm bore 12 Each
117 28.04 (d) 20 mm bore 12 Each
118 28.05 (e) 15 mm bore 10 Each
119 29 Supply and fixing GI Elbow of Havey grade with and including jointing meterial and taking out old unserviceable Elbow complete all as specified and directed of following sizes :- \nMake : Make : Jindal / TATA / Prakash Tubes
120 29.01 (a) 50 mm bore 10 Each
121 29.02 (b) 40 mm bore 10 Each
122 29.03 (c) 25 mm bore 12 Each
123 29.04 (d) 20 mm bore 12 Each
124 29.05 (e) 15 mm bore 10 Each
125 30 Supply and fixing 6" Nipple of Havey grade with and including jointing meterial and taking out old unserviceable Nipple complete all as specified and directed of following sizes :- \nMake : Make : Jindal / TATA / Prakash Tubes
126 30.01 (a) 50 mm bore 10 Each
127 30.02 (b) 40 mm bore 10 Each
128 30.03 (c) 25 mm bore 12 Each
129 30.04 (d) 20 mm bore 12 Each
130 30.05 (e) 15 mm bore 10 Each
131 31 Supply and fixing 12" Nipple of Havey grade with and including jointing meterial and taking out old unserviceable Nipple complete all as specified and directed of following sizes :- \nMake : Make : Jindal / TATA / Prakash Tubes
132 31.01 (a) 50 mm bore 10 Each
133 31.02 (b) 40 mm bore 10 Each
134 31.03 (c) 25 mm bore 12 Each
135 31.04 (d) 20 mm bore 12 Each
136 31.05 (e) 15 mm bore 10 Each
137 32 Draining out water from RCC Semi Underground Sump of under mentioned capacity, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes and writing the 'Date of Cleaning' outside all as specified and directed.
138 32.01 (a) 2,00,000 Gallons 2 Each Job
139 32.02 (b) 1,50,000 Gallons 1 Each Job
140 32.03 (c) 1,00,000 Gallons 1 Each Job
141 32.04 (d) 50,000 Gallons 1 Each Job
142 32.05 (e) 40,000 Litres 4 Each Job
143 32.06 (f) 30,000 Litres 3 Each Job
144 32.07 (g) 20,000 Litres 2 Each Job
145 32.08 (h) 10,000 Litres 1 Each Job
146 33 Cleaning of RCC Open Sump of capacity 0.50 Lakh Gallons by draining out of water, taking out the sludge deposited, cleaning of Wire Mesh Nets / walls and floor by scratching with wire brushes at Jaighati complete all as specified and as directed. \nNotes : \n1. The Contractor has to make arrangements for closing / diverting flowing water of Jai Nullah using mechanical means viz. JCB etc. before the cleaning commences and making good the disturbed surface after the cleaning process ends all as directed. \n2. The area upto 15 metres from the outer walls of the Sump shall be cleaned by removing the silt / sand / pebbles / stones etc. deposited / accumulated using mechanical means viz. JCB etc. and the excavated material shall be removed to a distance not exceeding 100 metres all as directed.\n3. The Quoted Rates shall be deemed to be inclusive of the above mentioned aspects and nothing extra from the department shall be admissible on this account. 1 Each Job
147 34 Masonry Valve Pit with PCC 1:4:8 type D-2 as in foundation, Brick Work 23cm thick in CM 1:4, 15mm thick plaster in CM 1:4 internally and flush pointing in same mortar as the work proceeds externally, 40mm thick flooring in PCC 1:2:4 type B-1 laid over 75mm thick hard core, top cover shall be made out of MS sheet 10 SWG thickness fixed in angle iron frame made out of angle size 40 x 40 x 6mm with 12mm dia handle and two number hinges on one side and locking arrangement at other side complete including painting with two coats of sythetic enamel paint over a coat of red oxide primer, complete including earth work, excavation, disposal of surplus spoil not exceeding 50m all as specified and directed of the following sizes :-
148 34.01 (a) 950mm x 950m x 950mm (internal dimension of chamber) 6 Each
149 34.02 (b) 600mm x 600m x 950mm (internal dimension of chamber) 6 Each
150 34.03 (c) 450mm x 450m x 700mm (internal dimension of chamber) 8 Each
151 35 Material and labour for lagging to pipes used in iternal/external water supply pipe lines all round with, 25 mm thick bonded mineral wool performed "SPAPON" pipe sections of density 144 Kg/Cum conforming to IS 9842 complete all as specified and directd by Engineer-in-Charge of following sizes:-
152 35.01 (a) 200 mm bore 20 Running meter
153 35.02 (b) 150 mm bore 50 Running meter
154 35.03 (c) 100 mm bore 20 Running meter
155 35.04 (d) 80 mm bore 20 Running meter
156 35.05 (e) 50 mm bore 60 Running meter
157 35.06 (f) 40 mm bore 60 Running meter
158 35.07 (g) 25 mm bore 70 Running meter
159 35.08 (h) 20 mm bore 73 Running meter
160 35.09 (j) 15 mm bore 55 Running meter
161 36 Supply only High Strength Calcium based granular disinfectant for water treatment, more stable than chlorine gas, and stronger than Bleaching Powder and Sodium Hypochlorite of following specifications :-\n(a) Chemical analysis & physical observations :\nDescription : Whitish granules of\ngranular size (Mesh passing through – 100 BSS) : 1.1 (± 0.1) % , Water / moisture : 5.00 (± 0.2) % Other insoluble Calcium salts: 1.1 (± 0.1) %\nMercury and other Heavy Metal contaminants : BDL (The chlorination chemical must contain appropriate quantities of dispersants / corrosion inhibitors to prevent encrustation / scaling in distribution systems) (b) Strength in terms of quantity of chlorination chemical required to obtain free chlorine of 1 ppm per lakh litres of water :\nRequirement must be 100 gm. per one lakh litre of water to achieve 05-1.0 ppm Av. Cl. at injection point (Site and raw water quality variations may apply additionally).\n(c) Stability : Projected shelf life of chlorination chemical must be one year with minimal loss of chlorine. \nMake : Purichlore / Mark Daxter / ALTOCH-Gp (Declivace Technologies Pvt Ltd) / Any E-in-C approved Make 1500 Kilogram
162 37 Supply only Hypochlorous Acid (HOCL) for chlorination of drinking water disinfection solution having high residual effect, clear colour less and potent germicide non-corrosive and non-foaming, stable upto 100° C for drinking water as and when required in HDPE Jerrycans of 35 litres capacity having the following features :-\n(a)  Potent germicide\n(b)  Slim control\n(c)  High residual effect to avoid contamination\n(d)  Less hazardous\n(e)  Work at low dosage in post disinfection\n(f)   No after taste\n(g)  Most reliable in operation\n(h)  Eco friendly and biodegradable\nMake : Penta Water Treatment / Seacolor / Hygene Maddox People Care / Super-Chlor Total 1500 Litres
163 38 Supply only Poly Aluminium Chloride Powder AC / 1005 suitable for treatment of raw water, complete all as specified & directed. \nMake : Acuro Organics Limited / Chemtex Speciality Limited / Akshar Exim Company Pvt Ltd 1500 Kilogram
164 39 Supply only Calcium Hypochlorite (Bleaching Powder) Each bag 25 Kg pkt for water treatment all as specified and directed by Engineer-in-Charge Make : Suvidhi Industries/ Arihant Chemical/Choice Organochem / Ama Speciality India/ AB Enterprises/Banke Behari Chemicals 1500 Kilogram
165 40 Supply only Solid Ferric Alum suitable for treatment of Raw water all as specified and directed by Engineer-in-Charge Make : Arihant Chemical/Shri Krishna Enterprises/Actuate Chemical Industries/Ama Speciality India 2500 Kilogram
Disclaimer :