Manipur State Power Company Limited has published 33Kv System Integration With Sldc System In Manipur . . Submission Date for this Tender is 03-12-2020. Customised Software Development Tenders in As Per Tender Document Manipur. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 23-Oct-2020 | Extension of Bid Submission and Opening for 33KV System Integration with SLDC system in Manipur. | Date | 07-11-2020 |
2 | 20-Nov-2020 | Extension of Bid Submission and opening for 33KV System Integration with SLDC system in Manipur. | Date | 03-12-2020 |
Name of Work: 33KV SYSTEM INTEGRATION WITH SLDC SYSTEM IN MANIPUR ON TURNKEY BASIS | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | I. OPGW & ADSS EQUIPMENT | 1 | ||
2 | 2 | A. OPGW CABLE & ACCESSORIES (33KV Lines) | 2 | ||
3 | 3 | i) 24 Fibre OPGW fibre optic cable | 3 | 16 | Km |
4 | 4 | ii) Installation Hardware set for 24 Fibre OPGW cable incl. all cable fittings & accessories except Joint Box | 4 | 16 | Set |
5 | 5 | iii) PVC Joint Box (24 Fibre) | 5 | 32 | Nos |
6 | 6 | B. ADSS CABLE & ACCESSORIES (33KV Lines) | 6 | ||
7 | 7 | i) 24 Fibre ADSS fibre optic cable | 7 | 133 | Km |
8 | 8 | ii) Installation Hardware set for 24 Fibre ADSS cable incl. all cable fittings & accessories except Joint Box | 8 | 133 | Set |
9 | 9 | iii) PVC Joint Box (24 Fibre) | 9 | 266 | Nos. |
10 | 10 | C. FODP | 10 | ||
11 | 11 | i) FODP 24F: Indoor type, rack mounted with FCPC coupling and pigtails | 11 | 15 | Nos. |
12 | 12 | ii) FODP 48F: Indoor type, rack mounted with FCPC coupling and pigtails | 12 | 15 | Nos. |
13 | 13 | D. FIBRE OPTIC APPROACH CABLE | 13 | ||
14 | 14 | i) 24 Fibre Approach Cable | 14 | 17 | Km |
15 | 15 | ii) Installation Hardware set for 24 Fibre Approach cable incl. all cable fittings & accessories | 15 | 1 | Set |
16 | 16 | E. UNDERGROUND FIBRE OPTIC CABLE & ACCESSORIES | 16 | ||
17 | 17 | i) Unarmoured Underground FO cable (24 Fibre DWSM) | 17 | 9 | Km |
18 | 18 | ii) Joint Box (24 Fibres) | 18 | 19 | No |
19 | 19 | iii) GI pipe 100 mm (Nominal bore), medium class (incl. access.) | 19 | 0.1 | Km |
20 | 20 | iv) RCC hume pipe (NP3), 100 mm dia (inside) | 20 | 50 | Mtr |
21 | 21 | v) PLB HDPE pipe O.D. 40 mm | 21 | 5 | Km |
22 | 22 | II. MANDATORY SPARES FOR OPGW & ADSS | 22 | ||
23 | 23 | A. OPGW cable & Accessories (33KV) | 23 | ||
24 | 24 | i) 24 Fibre OPGW fibre optic cable | 24 | 5 | Km |
25 | 25 | ii) Installation Hardware set for 24 Fibre cable incl. all cable fittings & accessories except Joint Box | 25 | 5 | Sets |
26 | 26 | iii) Joint Box (24 Fibre) | 26 | 3 | Nos |
27 | 27 | B. ADSS cable & Accessories (33KV) | 27 | ||
28 | 28 | i) 24 Fibre ADSS fibre optic cable | 28 | 10 | Km |
29 | 29 | ii) Installation Hardware set for 24 Fibre cable incl. all cable fittings & accessories except Joint Box | 29 | 10 | Sets |
30 | 30 | iii) Joint Box (24 Fibre) | 30 | 5 | Nos |
31 | 31 | C. Fibre Optic Approach Cable | 31 | ||
32 | 32 | i) 24 Fibre Approach Cable | 32 | 5 | Km |
33 | 33 | D. Underground Fibre Optic Cable & Accessories | 33 | ||
34 | 34 | i) Unarmoured Underground FO cable (24 Fibre DWSM) | 34 | 1 | Km |
35 | 35 | ii) Joint Box (24 Fibres) | 35 | 1 | Nos |
36 | 36 | E. Test Equipment | 36 | ||
37 | 37 | (i) Test Equipment for ADSS cable accessories | 37 | ||
38 | 38 | i) Optical Power meter (1310/1550nm) | 38 | 1 | Nos. |
39 | 39 | III. SDH EQUIPMENTS | 39 | ||
40 | 40 | A. SDH & PDH Equipment (STM4 with 5/3msp direction) | 40 | ||
41 | 41 | FOTE Equipment comprised of SDH & PCM Interfaces (Common cards, Redundant Power Supply cards, Redundant Control Cards, SDH Optical Base cards to support minimum four directions, VoIP based EOW Phone, power cabling, other hardware & accessories including sub-racks, patch cords, DDF etc. fully equipped excluding (B), (C) & (D) below with cabinet rack | 41 | 20 | Nos |
42 | 42 | B.Optical Cards/Interfaces | 42 | ||
43 | 43 | i) S1.1 | 43 | 20 | Nos. |
44 | 44 | ii) L1.1 | 44 | 20 | Nos. |
45 | 45 | iii) L1.2 | 45 | 20 | Nos. |
46 | 46 | C. Tributary Cards | 46 | ||
47 | 47 | i) E1 Interface card (Min. 16 interfaces per card) | 47 | 40 | Nos |
48 | 48 | ii) Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 4 interfaces per card) | 48 | 40 | Nos |
49 | 49 | D. Subscriber Line Interface Cards | 49 | ||
50 | 50 | i) 2 Wire (sub/sub) Voice Channel Card ( Min 12 channels) | 50 | 20 | Nos |
51 | 51 | ii) 2 Wire (Exch/sub) Voice Channel Card ( Min 12 channels) | 51 | 6 | Nos |
52 | 52 | iii) 2/4 Wire E&M Interface Card (Min 8 Channels) | 52 | 4 | Nos |
53 | 53 | iv) RS232/RS485 Serial data Card (Min 8 Channels) | 53 | 2 | Nos |
54 | 54 | E. Equipment Cabinets | 54 | ||
55 | 55 | i) For installing FOTE equipment | 55 | 20 | Nos |
56 | 56 | F. NMS | 56 | ||
57 | 57 | 1. Craft Terminal | 57 | ||
58 | 58 | i) Hardware | 58 | 1 | Set |
59 | 59 | ii) Software | 59 | 1 | Set |
60 | 60 | 2. Network Manager & Element Manager System | 60 | ||
61 | 61 | i) Hardware | 61 | 1 | Set |
62 | 62 | ii) Software | 62 | 1 | Set |
63 | 63 | iii) Printer (Laser Jet) | 63 | 1 | Set |
64 | 64 | 3. Remote Workstation | 64 | ||
65 | 65 | i) Hardware | 65 | 1 | Set |
66 | 66 | ii) Software | 66 | 1 | Set |
67 | 67 | G. Furniture for NMS Hardware | 67 | ||
68 | 68 | i) Furniture for NMS Hardware | 68 | 1 | Lot |
69 | 69 | H. Synchronization Equipment | 69 | ||
70 | 70 | i) GPS clock including all hardware and accessories | 70 | 1 | Set |
71 | 71 | I. Pre Connectorized Optical Fibre Patchcords (10 Mtrs) - Pack Of 6 Patch Cords | 71 | ||
72 | 72 | i) Pre Connectorized Optical Fibre Patchcords (10 Mtrs) - Pack Of 6 Patch Cords | 72 | 1 | Set |
73 | 73 | J. Telephony System | 73 | ||
74 | 74 | i) EPABX with 200 lines equipped with 100 Analog Extension lines, 8 Analog Trunk lines, 2 Digital Trunk lines with associated MDF etc. | 74 | 3 | Set |
75 | 75 | ii) 2 Wire Analog Telephone Set | 75 | 100 | Set |
76 | 76 | iii) Telephone Cable ( 2 pair unarmoured) | 76 | 1000 | Mtr |
77 | 77 | IV. MANDATORY SPARES FOR SDH EQUIPMENT | 77 | ||
78 | 78 | A. SDH/PDH EQUIPMENT (STMI UPGRADE TO STM4 BY CHANGING THE SFP) | 78 | ||
79 | 79 | i) FOTE Equipment comprised of SDH & PCM Interfaces (Common cards, Redundant Power Supply cards, Redundant Control Cards, SDH Optical Base cards to support minimum four directions, VoIP based EOW Phone, power cabling, other hardware & accessories including sub-racks, patch cords, DDF etc. fully equipped excluding (B) & (C) below with cabinet rack. | 79 | 1 | No. |
80 | 80 | B. OPTICAL CARDS/INTERFACES | 80 | ||
81 | 81 | i) S1.1 | 81 | 2 | No. |
82 | 82 | ii) L1.1 | 82 | 1 | No. |
83 | 83 | iii) L1.2 | 83 | 1 | No. |
84 | 84 | C. TRIBUTARY CARDS | 84 | ||
85 | 85 | i) E1 Interface card (Min. 16 interfaces per card) | 85 | 1 | No. |
86 | 86 | ii) Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) | 86 | 3 | No. |
87 | 87 | D. Pre Connectorized Optical Fibre Patch cords (10 Mtrs) - Pack of 6 Patch Cords | 87 | ||
88 | 88 | i) Pre Connectorized Optical Fibre Patch cords (10 Mtrs) - Pack of 6 Patch Cords | 88 | 1 | Set |
89 | 89 | V. RTU EQUIPMENT | 89 | ||
90 | 90 | i) RTU along with all accessories | 90 | 20 | Set |
91 | 91 | VI. APS MAIN EQUIPMENT | 91 | ||
92 | 92 | i) 15A SMPS based 48V DC Power Supply in N+1 module configuration for (DCPS) system | 92 | 20 | Nos |
93 | 93 | ii) Battery bank of 200AH for above DCPS (VRLA) for minimum 6 hours backup type | 93 | 20 | Nos |
94 | 94 | iii) Input ACDB | 94 | 2 | Nos |
95 | 95 | iv) Output ACDB | 95 | 2 | Nos |
96 | 96 | v) Accessories for maintenance of VRLA type battery | 96 | 10 | Set |
97 | 97 | VII. MANDATORY SPARES FOR DCPS | 97 | ||
98 | 98 | i) MMCB/MCB-2P/contactor/timer/Relay of each type 7 Rating (as applicable) for all stations | 98 | 1 | Set |
99 | 99 | ii) Single Pole MCBs for all stations | 99 | 1 | Nos |
100 | 100 | iiii) Electronic Printed Circuit Board / Card of each type (all cards/module including SMPS Module, DC Power Supply Controller, various interface cards etc.) for all substations | 100 | 1 | Set |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy