BOQ
| Name of Work: 33KV SYSTEM INTEGRATION WITH SLDC SYSTEM IN MANIPUR ON TURNKEY BASIS | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | I. OPGW & ADSS EQUIPMENT | 1 | ||
| 2 | 2 | A. OPGW CABLE & ACCESSORIES (33KV Lines) | 2 | ||
| 3 | 3 | i) 24 Fibre OPGW fibre optic cable | 3 | 16 | Km |
| 4 | 4 | ii) Installation Hardware set for 24 Fibre OPGW cable incl. all cable fittings & accessories except Joint Box | 4 | 16 | Set |
| 5 | 5 | iii) PVC Joint Box (24 Fibre) | 5 | 32 | Nos |
| 6 | 6 | B. ADSS CABLE & ACCESSORIES (33KV Lines) | 6 | ||
| 7 | 7 | i) 24 Fibre ADSS fibre optic cable | 7 | 133 | Km |
| 8 | 8 | ii) Installation Hardware set for 24 Fibre ADSS cable incl. all cable fittings & accessories except Joint Box | 8 | 133 | Set |
| 9 | 9 | iii) PVC Joint Box (24 Fibre) | 9 | 266 | Nos. |
| 10 | 10 | C. FODP | 10 | ||
| 11 | 11 | i) FODP 24F: Indoor type, rack mounted with FCPC coupling and pigtails | 11 | 15 | Nos. |
| 12 | 12 | ii) FODP 48F: Indoor type, rack mounted with FCPC coupling and pigtails | 12 | 15 | Nos. |
| 13 | 13 | D. FIBRE OPTIC APPROACH CABLE | 13 | ||
| 14 | 14 | i) 24 Fibre Approach Cable | 14 | 17 | Km |
| 15 | 15 | ii) Installation Hardware set for 24 Fibre Approach cable incl. all cable fittings & accessories | 15 | 1 | Set |
| 16 | 16 | E. UNDERGROUND FIBRE OPTIC CABLE & ACCESSORIES | 16 | ||
| 17 | 17 | i) Unarmoured Underground FO cable (24 Fibre DWSM) | 17 | 9 | Km |
| 18 | 18 | ii) Joint Box (24 Fibres) | 18 | 19 | No |
| 19 | 19 | iii) GI pipe 100 mm (Nominal bore), medium class (incl. access.) | 19 | 0.1 | Km |
| 20 | 20 | iv) RCC hume pipe (NP3), 100 mm dia (inside) | 20 | 50 | Mtr |
| 21 | 21 | v) PLB HDPE pipe O.D. 40 mm | 21 | 5 | Km |
| 22 | 22 | II. MANDATORY SPARES FOR OPGW & ADSS | 22 | ||
| 23 | 23 | A. OPGW cable & Accessories (33KV) | 23 | ||
| 24 | 24 | i) 24 Fibre OPGW fibre optic cable | 24 | 5 | Km |
| 25 | 25 | ii) Installation Hardware set for 24 Fibre cable incl. all cable fittings & accessories except Joint Box | 25 | 5 | Sets |
| 26 | 26 | iii) Joint Box (24 Fibre) | 26 | 3 | Nos |
| 27 | 27 | B. ADSS cable & Accessories (33KV) | 27 | ||
| 28 | 28 | i) 24 Fibre ADSS fibre optic cable | 28 | 10 | Km |
| 29 | 29 | ii) Installation Hardware set for 24 Fibre cable incl. all cable fittings & accessories except Joint Box | 29 | 10 | Sets |
| 30 | 30 | iii) Joint Box (24 Fibre) | 30 | 5 | Nos |
| 31 | 31 | C. Fibre Optic Approach Cable | 31 | ||
| 32 | 32 | i) 24 Fibre Approach Cable | 32 | 5 | Km |
| 33 | 33 | D. Underground Fibre Optic Cable & Accessories | 33 | ||
| 34 | 34 | i) Unarmoured Underground FO cable (24 Fibre DWSM) | 34 | 1 | Km |
| 35 | 35 | ii) Joint Box (24 Fibres) | 35 | 1 | Nos |
| 36 | 36 | E. Test Equipment | 36 | ||
| 37 | 37 | (i) Test Equipment for ADSS cable accessories | 37 | ||
| 38 | 38 | i) Optical Power meter (1310/1550nm) | 38 | 1 | Nos. |
| 39 | 39 | III. SDH EQUIPMENTS | 39 | ||
| 40 | 40 | A. SDH & PDH Equipment (STM4 with 5/3msp direction) | 40 | ||
| 41 | 41 | FOTE Equipment comprised of SDH & PCM Interfaces (Common cards, Redundant Power Supply cards, Redundant Control Cards, SDH Optical Base cards to support minimum four directions, VoIP based EOW Phone, power cabling, other hardware & accessories including sub-racks, patch cords, DDF etc. fully equipped excluding (B), (C) & (D) below with cabinet rack | 41 | 20 | Nos |
| 42 | 42 | B.Optical Cards/Interfaces | 42 | ||
| 43 | 43 | i) S1.1 | 43 | 20 | Nos. |
| 44 | 44 | ii) L1.1 | 44 | 20 | Nos. |
| 45 | 45 | iii) L1.2 | 45 | 20 | Nos. |
| 46 | 46 | C. Tributary Cards | 46 | ||
| 47 | 47 | i) E1 Interface card (Min. 16 interfaces per card) | 47 | 40 | Nos |
| 48 | 48 | ii) Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 4 interfaces per card) | 48 | 40 | Nos |
| 49 | 49 | D. Subscriber Line Interface Cards | 49 | ||
| 50 | 50 | i) 2 Wire (sub/sub) Voice Channel Card ( Min 12 channels) | 50 | 20 | Nos |
| 51 | 51 | ii) 2 Wire (Exch/sub) Voice Channel Card ( Min 12 channels) | 51 | 6 | Nos |
| 52 | 52 | iii) 2/4 Wire E&M Interface Card (Min 8 Channels) | 52 | 4 | Nos |
| 53 | 53 | iv) RS232/RS485 Serial data Card (Min 8 Channels) | 53 | 2 | Nos |
| 54 | 54 | E. Equipment Cabinets | 54 | ||
| 55 | 55 | i) For installing FOTE equipment | 55 | 20 | Nos |
| 56 | 56 | F. NMS | 56 | ||
| 57 | 57 | 1. Craft Terminal | 57 | ||
| 58 | 58 | i) Hardware | 58 | 1 | Set |
| 59 | 59 | ii) Software | 59 | 1 | Set |
| 60 | 60 | 2. Network Manager & Element Manager System | 60 | ||
| 61 | 61 | i) Hardware | 61 | 1 | Set |
| 62 | 62 | ii) Software | 62 | 1 | Set |
| 63 | 63 | iii) Printer (Laser Jet) | 63 | 1 | Set |
| 64 | 64 | 3. Remote Workstation | 64 | ||
| 65 | 65 | i) Hardware | 65 | 1 | Set |
| 66 | 66 | ii) Software | 66 | 1 | Set |
| 67 | 67 | G. Furniture for NMS Hardware | 67 | ||
| 68 | 68 | i) Furniture for NMS Hardware | 68 | 1 | Lot |
| 69 | 69 | H. Synchronization Equipment | 69 | ||
| 70 | 70 | i) GPS clock including all hardware and accessories | 70 | 1 | Set |
| 71 | 71 | I. Pre Connectorized Optical Fibre Patchcords (10 Mtrs) - Pack Of 6 Patch Cords | 71 | ||
| 72 | 72 | i) Pre Connectorized Optical Fibre Patchcords (10 Mtrs) - Pack Of 6 Patch Cords | 72 | 1 | Set |
| 73 | 73 | J. Telephony System | 73 | ||
| 74 | 74 | i) EPABX with 200 lines equipped with 100 Analog Extension lines, 8 Analog Trunk lines, 2 Digital Trunk lines with associated MDF etc. | 74 | 3 | Set |
| 75 | 75 | ii) 2 Wire Analog Telephone Set | 75 | 100 | Set |
| 76 | 76 | iii) Telephone Cable ( 2 pair unarmoured) | 76 | 1000 | Mtr |
| 77 | 77 | IV. MANDATORY SPARES FOR SDH EQUIPMENT | 77 | ||
| 78 | 78 | A. SDH/PDH EQUIPMENT (STMI UPGRADE TO STM4 BY CHANGING THE SFP) | 78 | ||
| 79 | 79 | i) FOTE Equipment comprised of SDH & PCM Interfaces (Common cards, Redundant Power Supply cards, Redundant Control Cards, SDH Optical Base cards to support minimum four directions, VoIP based EOW Phone, power cabling, other hardware & accessories including sub-racks, patch cords, DDF etc. fully equipped excluding (B) & (C) below with cabinet rack. | 79 | 1 | No. |
| 80 | 80 | B. OPTICAL CARDS/INTERFACES | 80 | ||
| 81 | 81 | i) S1.1 | 81 | 2 | No. |
| 82 | 82 | ii) L1.1 | 82 | 1 | No. |
| 83 | 83 | iii) L1.2 | 83 | 1 | No. |
| 84 | 84 | C. TRIBUTARY CARDS | 84 | ||
| 85 | 85 | i) E1 Interface card (Min. 16 interfaces per card) | 85 | 1 | No. |
| 86 | 86 | ii) Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) | 86 | 3 | No. |
| 87 | 87 | D. Pre Connectorized Optical Fibre Patch cords (10 Mtrs) - Pack of 6 Patch Cords | 87 | ||
| 88 | 88 | i) Pre Connectorized Optical Fibre Patch cords (10 Mtrs) - Pack of 6 Patch Cords | 88 | 1 | Set |
| 89 | 89 | V. RTU EQUIPMENT | 89 | ||
| 90 | 90 | i) RTU along with all accessories | 90 | 20 | Set |
| 91 | 91 | VI. APS MAIN EQUIPMENT | 91 | ||
| 92 | 92 | i) 15A SMPS based 48V DC Power Supply in N+1 module configuration for (DCPS) system | 92 | 20 | Nos |
| 93 | 93 | ii) Battery bank of 200AH for above DCPS (VRLA) for minimum 6 hours backup type | 93 | 20 | Nos |
| 94 | 94 | iii) Input ACDB | 94 | 2 | Nos |
| 95 | 95 | iv) Output ACDB | 95 | 2 | Nos |
| 96 | 96 | v) Accessories for maintenance of VRLA type battery | 96 | 10 | Set |
| 97 | 97 | VII. MANDATORY SPARES FOR DCPS | 97 | ||
| 98 | 98 | i) MMCB/MCB-2P/contactor/timer/Relay of each type 7 Rating (as applicable) for all stations | 98 | 1 | Set |
| 99 | 99 | ii) Single Pole MCBs for all stations | 99 | 1 | Nos |
| 100 | 100 | iiii) Electronic Printed Circuit Board / Card of each type (all cards/module including SMPS Module, DC Power Supply Controller, various interface cards etc.) for all substations | 100 | 1 | Set |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender