Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #25596405

Construction Of Block Development Office Bangana Distt Una Hp Sh Providing Electrical Installation And Main Panel Therein Block Part I

Issued by Local Bodies · Bangana, Himachal Pradesh
Tender Value
10.74 Lakhs
Estimated cost
Bid Submission
15 Oct 2020
0 days left
EMD
21500
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bangana → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Block Development Office Bangana Distt Una Hp Sh Providing Electrical Installation And Main Panel Therein Block Part I

BOQ

Name of Work: C/O Block Development Office Bangana Distt. Una (H.P.) [ SH : - Providing Electrical Installation & Main Panel therein] Block/ Part-I
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.BI01010001010000000000000515BI0100001113
21.01Group C.BI01010001010000000000000515BI0100001114307point
32Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.BI01010001010000000000000515BI0100001115
42.01Group C.12point
53Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.22each
64Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.44each
75Supplying and fixing of Single Pole 25 Amp. 240V MCB and socket outlet complete with sheet steel encloser, mounting box and cover including plug top, ready to use with existing Air Condicitioner on surface or in recess, complete with connections, testing and commissioning etc. as required. Make : Havells, L&T or any other approved by Enginner-in-charge.21each
86Supplying and fixing electrical switch board, having 4 No. of 5/6 amp. Modular Switches and Modular Socket on suitable size of G.I. modular boxes of 12 modules (205mmx135mmx60mm) deep ( nominal size) on surface or in recess with suitable size along with modular base and cover plate for modular switches in the front including providing and fixing 4 No. 5 pin 5/6 amp modular socket outlet and 5/6 amp modular switch, connection, painting etc.as required. (For Light Plug/Computer Points)37each
97Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
107.01Single pole 6 Amp. Cat-A.81each
117.02Single pole 16 Amp. Cat-A.44each
127.03Single pole 25 Amp. Cat-A.21each
138Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
148.01Double pole. 40 Amp.Cat-A.12each
158.02Double pole. 63 Amp. Cat-A.12each
169Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
179.0140 Amps. Cat-A.12each
189.0263 Amps. Cat-A.12each
1910Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
2010.01Double door-8 way1each
2110.02Double door-12 way23each
2211Providing, fixing and installation of following rating and breaking capacity MCCB with Thermal Release Having inbuilt Overload and Short Circuit Protection in the existing cubical panel board suitable for input voltage: 415/500 Volt AC, 50 Hz, complete with all accesories, including making connections, testing and commissioning etc. as required. Make: L&T, Havells, Schneider, Standard or any other approved by Engineer-in-Charge.
2311.01MCCB DU100H 3-Pole 63 Amp Breaking Capacity 30-KA2each
2411.02MCCB DU100H 3-Pole 100 Amp Breaking Capacity 30-KA4each
2512Supplying and fixing of MCCB Enclosure,suitable for 3-pole or 4-pole MCCB, on surface / recess, complete with tinned neutral link, earth bar, din-bar, detachable gland plate, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Make: L&T, Havells or any other approved by Engineer-in-Charge.
2612.01MCCB Enclosure Siza-I for DU100H/DU125H/DU100D/DU125D/DN06each
2713Supplying and fixing sheet metal bus-bar chamber suitable for 63 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 450mm & cross-sectional area (16mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (530mmx350mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-2each
2814Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 450mm & cross-sectional area (25.4mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (530mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-4each
2915Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron (25 mm x 25 mm x 6 mm thick) with sufficient numbers of horizontal and vertical intermediate members (25mm x 6mm thick) flat iron including painting and bonding to the existing earth as required:-6Sq. mtr.
3016Supplying and erection of floor mounted fixed type metal frame work / boards of welded construction for switch gear mounting fabricated with M.S. angle iron (50 mm x 50 mm x 6 mm thick) of suitable dimensions with supporting members grouted 23 cm underground and frame work covered with 3mm thick M.S. sheet from top to a given height, with M.S. angle iron / 50mmx50mmx 6mm thick welded on the back and grouted into the back wall complete with painting and bonding to the existing earth as required:-2Sq. mtr.
3117Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
3217.012x1.5 Sq. mm.490Meter
3317.022x2.5 Sq. mm.270Meter
3417.032x6.0 Sq. mm.190Meter
3517.042x10 Sq. mm.215Meter
3618Wiring for circuit/sub-main with 4x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.1.5 Sq.mm.(4X1.5+2X1.5) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.155Meter
3719Wiring for circuit/sub-main with 4x2.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.2.5 Sq.mm.(4X2.5+2X2.5) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.200Meter
3820Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.540Meter
3921Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.373Meter
4022Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, unarmoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
4122.01Unarmoured cable 16 sq. mm (four core)20R.Mtr.
4222.02Unarmoured cable 25 sq. mm (3.5 core)70R.Mtr.
4323Sub-Main Distribution Panel:- Providing and fixing floor/wall mounted L&T make SMDB Panel TN400D, O/G 100A 8-Ways Panel, having Main MCCB Incomer 400 Amp. & Outgoing 8-Way Sub-Incomer 100 Amp. of suitable dimensions made from 1.6 mm thick CRCA sheet, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels, interconnections, phosphatized and powder painted and LED phase indicating set, Digitial Metering complete with following accessories including earthing etc. as required : - SMDB Panel Highlights: -?Compliance with latest standard - IEC 61439-3,?DEKRA and ASTA certified, ? Ingress protection - IP 44,Provision for :-Main MCCB Incomer 400 Amp.Outgoing 8-way Sub-Incomer MCCB 250 Amp.Size: - 1087mm(H) x 870mm(W) x 208.5mm(D)Cat.No.- DA40D1084CZZ0 = 1 No. Incoming Device: - ?DN3-400D 3 Pole MCCB - 400A breaking capacity-50KA = 1 No.Cat.No.- CM94005OOR1OG, Outgoing Device: -?DN0-100D 3 Pole MCCB - 100 A breaking capacity-36KA = 8 No. Cat.No.- CM97893OOK2OG,Metering, Bottom Cabling & Corner Box: - ?Provision of 3 nos of 1-phase ammeter (96x96), 1 nos of 1-phase voltmeter (96x96) with voltage selector switch & indicating lamps Metering Extension Box [Cat.No.CM90439OOPO] = 1 No.Bottom Cabling Box [Cat.No.CM91062OOOO] = 1 No.Corner Box [Cat.No.CM91089OOOO] = 4 No.Left Side Cabling Box [Cat.No.CM91087OFOO] = 1 No.Right Side Cabling Box [Cat.No.CM91088OFOO] = 1 No.1Ph LED Ammeter Cl 1 [Cat.No.WL111010OOOO] = 3 No.1Ph LED Voltmeter Cl 1 [Cat.No.WL111010OOOO] = 1 No.Voltmeter Selector Switche [Cat.No.61312 SAB13TDYR] = 1 No.LED RED Indicator 22.5 mm [Cat.No.EILR240A] = 1 No.LED Yellow Indicator 22.5 mm [Cat.No.EILY240A] = 1 No.LED Blue Indicator 22.5 mm [Cat.No.EILB240A] = 1 No.1each

AI Tender Summary

OUR REF NO 25596405
AUTHORITY Local Bodies
TENDER VALUE 10.74 Lakhs
LAST DATE 15-10-2020
Authority
Authority Name Rural Development And Panchayats Department
Work Description Construction Of Block Development Office Bangana Distt Una Hp Sh Providing Electrical Installation And Main Panel Therein Block Part I
Basic Detail
Tender No RDD Shimla Bangana
Bidding Type Tender
Location
City Bangana
State Himachal Pradesh
Key Dates
Publish Date 01 Oct 2020
Submission Date 15 Oct 2020
Open Date 17 Oct 2020
Finance
Tender Value 10.74 Lakhs
Tender Fee 350
EMD 21500
Exemption Not Available
Document List
BOQ_60803.xls
banganabid.pdf
0B1A3706-B7F3-4C5F-916A-AC8875389F45.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 15, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 17, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_60803.xls

pdf

banganabid.pdf

html

0B1A3706-B7F3-4C5F-916A-AC8875389F45.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders