Repair Maintenance Of Htlt Overhead Lines Under Ground Cables Panels Dehydration Transformer And Maint Of Transformer Vcbs And Connected Em Wks At Rts D Saharanpur Under Ge Roorkee, Roorkee-Uttarakhand

Military Engineer Services-MES has published Repair Maintenance Of Htlt Overhead Lines Under Ground Cables Panels Dehydration Transformer And Maint Of Transformer Vcbs And Connected Em Wks At Rts D Saharanpur Under Ge Roorkee. Submission Date for this Tender is 22-10-2020. Circuit Breakers Tenders in Roorkee Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

25590015
Repair Maintenance Of Htlt Overhead Lines Under Ground Cables Panels Dehydration Transformer And Maint Of Transformer Vcbs And Connected Em Wks At Rts D Saharanpur Under Ge Roorkee
Open Tender
Indian
Uttarakhand
Roorkee
22-10-2020

Tender Details

Repair Maintenance Of Htlt Overhead Lines Under Ground Cables Panels Dehydration Transformer And Maint Of Transformer Vcbs And Connected Em Wks At Rts D Saharanpur Under Ge Roorkee

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:REPAIR/MAINT OF HT/LT OVERHEAD LINES, UNDER GROUND CABLES, PANELS, DEHYDRATION TRANSFORMER AND MAINT OF TRANSFORMER AND MAINT OF TRANSFORMER, VCBs AND CONNECTED E/M WORKS AT RTS & D SAHARANPUR UNDER GE ROORKEE
Sl. No. Item Description Item Code / Make Qty Units
1 1 Disconnecting defective transformer indoor/outdoor of capacity 400KVA both from HT/LT sides, and then drainage of complete transformer oil, opening of top cover with due care and removal of all HT/LT winding connections from bushing and then lifting of core by means of tripod and chain pulley with due care for inspection and ascertain it’s serviceability state after keeping it aside. Removal of all sludge and unwanted material from tank and core, lowering of core assembly after carrying out required repairs to the winding and core. In case the repairs which are not possible at site then the transformer has to be taken to the work shop for repairs, and installation back to original position after repairing and connecting, testing complete all as directed at site by Engr-In-Charge.\nNote :- (i) The cost of transportation shall be deemed to be included in the quoted rate by the conractor. \n(ii) The cost of rewinding shall be paid separately. \n(iii) The cost of dehydration/filtration & other necessary repair as directed shall be measured & paid separately under relevant items of this schedule.\n(iv) Additional transformer oil for top-up, if required will be filled by contractor and shall be paid under respective item of this schedule. BI01010001010000000000000515BI0100001112 1 Each Job
2 2 Disconnecting defective transformer indoor/outdoor of any capacity up to 160-250KVA both from HT/LT sides, and then drainage of required transformer oil. Opening of top cover LT and HT side bushings with due care and removal of all HT/LT winding connections from bushing and then replacement of head gasket, LT and HT bushing packings complete and ensured that no leakage in transformer from LT/HT bushing and top cover gasket as directed by Engr-in-Charge. BI01010001010000000000000515BI0100001113 1 Each Job
3 3 Disconnecting defective transformer indoor/outdoor of any capacity up to 25-100KVA both from HT/LT sides, and then drainage of required transformer oil. Opening of top cover LT and HT side bushings with due care and removal of all HT/LT winding connections from bushing and then replacement of head gasket, LT and HT bushing packings complete and ensured that no leakage in transformer from LT/HT bushing and top cover gasket as directed by Engr-in-Charge. BI01010001010000000000000515BI0100001114 1 Each Job
4 4 Taking down of transformers of capacity25/63/100 KVA from 2/4pole structure or from PCC platform with due care after disconnecting all HT/LT connections on pole mounted structures, Transportation of transformer to workshop from site of installation to workshop for repairs including loading and unloading of transformer, and replacing it to site from where it was taken for repairs as per site requirement and then lowering it by means of crane and remounting on 2/4pole structure after repairs with all connection complete all as directed and specified by engineer in charge. BI01010001010000000000000515BI0100001115 1 Each Job
5 5 Shifting of transformers of capacity 25/63/100/160/250/400 KVA from 2/4pole structure or from PCC platform with due care after disconnecting all HT/LT connections on pole mounted structures, Transportation of transformer to PCC/ 2 or 4 pole structure to any other required location at RTS & Depot , Saharanpur lowering and remounting on 2/4pole structure it by means of crane after disconnecting all connection and reconnection in new location including earthing connection and as directed and specified by engineer in charge. BI01010001010000000000000515BI0100001116 1 Each Job
6 6 Material and labour for replacement of worn out HT copper coils made out of super enamelled insulated copper wire all as per existing size and shape including all insulating, binding, material and then varnishing complete all as specified and directed by engineer in charge BI01010001010000000000000515BI0100001117 180 Kg
7 7 Material and labour for replacement of worn out LT copper coils made out of super enamelled insulated copper strip all as per existing size and shape including all insulating, binding, material and then varnishing complete all as specified and directed by engineer in charge BI01010001010000000000000515BI0100001118 160 Kg
8 8 Dehydration/centrifuging of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition of transformer including testing of transformer oil before and after centrifuging from top and bottom of transformer at 4mm gap the break down voltage should be 50KV complete all as specified and directed by engineer in charge. BI01010001010000000000000515BI0100001119 2500 Ltrs
9 9 Supply and topping up of transformer oil of dielectric strength of 65 KV complete all as specified and directed by engineer in charge. BI01010001010000000000000515BI0100001120 600 Ltrs
10 10 Material and labour for replacement of worn out bushing rod made out of brass with heavy duty three nuts and three washer at both ends suitable for HT side all as per exiting size, shape and length suitable for following capacity transformers :-\n (i)   160 – 250 KVA Transformers. BI01010001010000000000000515BI0100001121 2 Each
11 10.01 (ii)      400 KVA Transformer. BI01010001010000000000000515BI0100001122 1 Each
12 10.02 (iii) 25 - 100 KVA BI01010001010000000000000515BI0100001123 4 Each
13 11 Material and labour for replacement of worn out bushing rod made out of made out brass with heavy duty three nuts and three washer at both ends suitable for LT side all as per existing size, shape and length suitable for following capacity transformers :-\n(i)   160 – 250 KVA Transformers. BI01010001010000000000000515BI0100001124 1 Each
14 11.01 (ii)      400 KVA Transformer. BI01010001010000000000000515BI0100001125 1 Each
15 11.02 (iii) 25 - 100 KVA BI01010001010000000000000515BI0100001126 1 Each
16 12 Material and labour for replacement of worn out porcelain bushing for 11KV HT side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by engineer in charge suitable for following capacity transformers:-\n(i)   160 – 250 KVA Transformers. BI01010001010000000000000515BI0100001127 1 Each
17 12.01 (ii)      400 KVA Transformer. BI01010001010000000000000515BI0100001128 1 Each
18 12.02 (iii) 25 - 100 KVA BI01010001010000000000000515BI0100001129 1 Each
19 13 Material and labour for replacement of worn out porcelain bushing for .433 KV LT side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by engineer in charge suitable for following capacity transformers:-\n (i)   160 – 250 KVA Transformers. BI01010001010000000000000515BI0100001130 1 Each
20 13.01 (ii)      400 KVA Transformer. BI01010001010000000000000515BI0100001131 1 Each
21 13.02 (iii) 25 - 100 KVA BI01010001010000000000000515BI0100001132 1 Each
22 14 Material and labour for replacement of worn out rubberised cork sheet 4mm thick for transformer top cover all as required at site and as directed by engineer in charge suitable for following capacity transformers:-\n(i)   160 – 250 KVA Transformers. BI01010001010000000000000515BI0100001133 1 Each
23 14.01 (ii)      400 KVA Transformer. BI01010001010000000000000515BI0100001134 1 Each
24 14.02 (iii) 25 - 100 KVA BI01010001010000000000000515BI0100001135 1 Each
25 15 Material and labour for replacement of worn out rubberised cork sheet 4mm thick suitable for HT/LT side bushing of off sizes all as required at site and directed by engineer in charge. BI01010001010000000000000515BI0100001136 2 Each
26 16 Preparation of old surface of transformer for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun at site of installation of transformer complete all as specified and directed by engineer in charge suitable for following capacity of transformer:-\n(Note for Sl No-16 colour code of transformer :- (i) Body - Smoke grey \n(ii) Vent pipe, drain plug - Red (iii) Base plate/C-section, iron wheel -Black\n(iv) Writing MES/SM No - White)\n(i)           Upto 160 KVA. BI01010001010000000000000515BI0100001137 8 Each
27 16.01 (i)           160 – 250 KVA. BI01010001010000000000000515BI0100001138 2 Each
28 16.02 (ii)           400 KVA BI01010001010000000000000515BI0100001139 1 Each
29 17 Material and labour for replacement of worn out silica gel breather in transparent body all as per existing sample suitable for following capacity of transformers of any make.:-\n(i)      160 – 250 KVA. BI01010001010000000000000515BI0100001140 4 Each
30 17.01 (ii)        400 KVA BI01010001010000000000000515BI0100001141 1 Each
31 17.02 (iii) 25 - 100 KVA BI01010001010000000000000515BI0100001142 6 Each
32 18 Material and labour for replacement of unserviceable off load tap changer assembly all as per existing sample suitable for following capacity of transformers of any make.:-\n(i)      160 – 250 KVA. BI01010001010000000000000515BI0100001143 1 Each
33 18.01 (ii)        400 KVA BI01010001010000000000000515BI0100001144 1 Each
34 18.02 (iii) 25 - 100 KVA BI01010001010000000000000515BI0100001145 1 Each
35 19 Material and labour for oil temperature gauge /thermometer suitable for transformers all as per existing shape and size for any make and model transformers all as specified and directed by engineer in charge. BI01010001010000000000000515BI0100001146 4 Each
36 20 Supply testing jointing and commissioning of Cold shrinkable type straight through joint kit and incl jointing materials suitable for cable size 50 to 95 sq mm 3 Core X LPE 11 KV cable complete all as spd and directed . Make- Raychem/ Dension/ Mseal BI01010001010000000000000515BI0100001147 1 Each
37 21 Supply testing jointing and commissioning of indoor Heat shrinkable end tremination joint kit and incl jointing materials suitable for cable size 50-95 sq mm 3 Core X LPE 11 KV cable complete all as spd and directed . Make- Raychem/ Dension/ Mseal BI01010001010000000000000515BI0100001148 1 Each
38 22 Supply testing jointing and commissioning of outdoor heat shrinkable end tremination joint kit and incl jointing materials suitable for cable size50- 95 sq mm 3 Core X LPE 11 KV cable complete all as spd and directed . Make- Raychem/ Dension/ Mseal BI01010001010000000000000515BI0100001149 1 Each
39 23 Supply testing jointing and commissioning of outdoor Heat shrinkable end tremination joint kit and incl jointing materials suitable for cable size 70-95 sq mm 3 Core X LPE 11 KV cable complete all as spd and directed . Make- Raychem/ Dension/ Mseal BI01010001010000000000000515BI0100001150 7 Each
40 24 S&F as in replacement Digital protective relays comprising of 3 Phase over current plus earth fault relay with high set operational with 24 volt to 110 volts AC / DC, including its calibration by using Primary/Secondary injection of the existing make including complete wiring with suitable size wire Relay make & Model No. Schineder P-122 and fixing arrangement complete as specified and directed. BI01010001010000000000000515BI0100001151 1 Each
41 25 M&L as in replacement of Battery bank consisting of 2 Volts tubular battery (12 Nos) 40 AH aggregating 24 Volts capacity for 11 KV VCB, rating 630 Amp make ABB. BI01010001010000000000000515BI0100001152 1 Each Job
42 26 Supply and fixing battery charger for charging battery bank of 24 Volts capacity with all connections and brass terminals BI01010001010000000000000515BI0100001153 1 Each Job
43 27 M&L as in replacement of HRC fuses of PT of existing make for 11 KV VCB, rating 630 Amp, Make ABB. BI01010001010000000000000515BI0100001154 3 Nos
44 28 M&L as in replacement of Current Transformers of existing make for 11 KV VCB rating 630 Amp, Make : ABB. BI01010001010000000000000515BI0100001155 1 Set of 3
45 29 M&L as in replacement of Multifunction meter, all as per legrand model No PMX 7000 or equivalent in L&T /HPL/ Schineider for 11 KV VCB, Make : ABB, 630 Amp rating. BI01010001010000000000000515BI0100001156 2 Nos
46 30 M&L in replacement of spring Charging motor of VCB working on 24 Volts DC supply and operated as per existing torque and RPM (630 Amp rating 11 KV VCB) Make: ABB. BI01010001010000000000000515BI0100001157 1 Nos
47 31 Testing and calibration of existing Micro processor based digital programmer Protection relay unit having over current handling capacity up to 10 Amps for 10 milli sec and Earth fault arrest less then 04 milli sec to arrest the fault of individual VCB and by using primary and secondary injection at site complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001158 1 Each Job
48 32 Supply and fix drop out fuse unit explusion type for out door switch triple pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts, and washer etc. Synthetic bounded fuse carrying tube complete with flip mechanism suitable for current carry capacity upto 200 Amps all as directed. ( set of three) BI01010001010000000000000515BI0100001159 1 Set of 3
49 33 M&L for servicing and overhauling of HT 11 KV RMU with one incoming and two outgoing Make ABB by dismantling the complete breaker and its mechanism, checking various parts and its critical setting in mechanism, busbar chamber,Electric short circuit mechanisms, fuses , fuse conister, feeder busbar internal/external busbar, SF6 tank, HV compartment, auxiliary switch, interlocking lever, current transformer relay etc. checking and repairing of spring charging mechanism, checking and repairing of pole contact , greasing/ lubricating of mechanism moving parts, checking of contact pressure, alignment and adjusting the same, replacement of tripping coil and performing minor mechanism repairs, test trial & testing of RMU for smooth and correct functioning by ABB Energy or authorized company rep complete all as specified and directed by Engr-in-Charge incl topping up, replacement of SF 6 gas and replacement of 11KV 25-400KVA buchholz relay valve. Incl replacement of charging mechanism for RMU, calibrating testing complete to the satisfaction of Engr-In-Charge.\nNote :- Contractor shall visit the site before quoting rates for the above item to assess the nature of repairs.\n BI01010001010000000000000515BI0100001160 1 Job
50 34 M&L in replacement of tripping/ closing coils suitable for 11KV VCB Make : ABB BI01010001010000000000000515BI0100001161 1 Each
51 35 M&L in replacement of Rectifier for motor circuit of 11KV VCB of make ABB BI01010001010000000000000515BI0100001162 1 Each
52 36 M&L in replacement of tripping shaft with spring for 11KV VCB of make ABB BI01010001010000000000000515BI0100001163 1 Each
53 37 Supply only tinned copper fuse wire of capacity 10-60 Amp for drop out fuse. BI01010001010000000000000515BI0100001164 2 Kg
54 38 Supply only electrical Rubber hand gloves, 11KV, ISI mark BI01010001010000000000000515BI0100001165 2 Pair
55 39 Supply and fix vertical type air break gang operated triple pole, mechanically operated, outdoor type with all fittings, accessories, mounted on and including HT 11 KV porcelain insulators and steel channel frame GI Operating rod 25 mm dia of suitable length worked from ground including locking arrangements, with 7 livers Naval brass lock, suitable for 200 Amps current rating complete.(set of three) BI01010001010000000000000515BI0100001166 1 Each Set
56 40 Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in HT/LT underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed BI01010001010000000000000515BI0100001167 95.1885 Cum
57 41 Returning, filling, spreading, levelling, watering & well ramming in layers n.exc 25 cm thick as in soil complete all as specified and directed. BI01010001010000000000000515BI0100001168 43.3 Cum
58 42 Removing excavated soil n.exc 50 mtr and depositing as directed n.exc 1.5 mtr above the starting point complete all as specified and directed. BI01010001010000000000000515BI0100001169 49.51 Cum
59 43 M&L dry clean Sand filling in trenches around underground cables for cushioning, complete all as specified and directed. \nNote: Depth of sand shall be measured after punning complete all as specified and directed. BI01010001010000000000000515BI0100001170 36.86 Cum
60 44 Supply and laying in replacement of reinforced precast concret cable cover class HV, flate size 300 X 180 X40mm complete as specified and directed BI01010001010000000000000515BI0100001171 56 Nos
61 45 M&L for PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in Coping of pole/Stay etc. including necessary form work for coping and finished the surface even in fair complete all as specified and directed at site. BI01010001010000000000000515BI0100001172 2.136 Cum
62 46 M&L for PCC 1:4:8) type D-2 using 40mm graded stone aggregate in foundation of PCC poles/struts as specified including necessary form work all as specified and directed. BI01010001010000000000000515BI0100001173 0.2 Cum
63 47 M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. BI01010001010000000000000515BI0100001174 0.264 Cum
64 48 M&L for High Tension cable fault checking by high tension cable fault testing machine by disconnecting the HT cable end termination including insulation testing complete of faulty cable.complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001175 2 Each
65 49 S&F as in replacement of HV backup fuse link, CEF cap iN 25Amp i3 55 A, UN 12Kv i163 A, Striker 60N in SF6 RMU Make ABB cat part No IYMB5301035M0004, complete all as spd and as directed. (set of Three) BI01010001010000000000000515BI0100001176 1 Each Set
66 50 M&L in replacement of aluminium conductor, steel reinforced off sizes including binding wire and jumper connect with PG clamp made out of aluminium alloy according to IS-617 complete all as specified and directed by Engr-in-charge. BI01010001010000000000000515BI0100001177 3 Qtl
67 51 Supply and fix HT 11 KV outdoor non-linear type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure/GI flat strip and connect with same size of ACSR conductor encased in PVC alkathine pipe with all fittings connected to earth strip with nut, bolt, washer transmission class having discharge capacity of 10 kilo Amps and suitable for working pressure complete all as specified and directed complete. BI01010001010000000000000515BI0100001178 1 Set of 3
68 52 Supply only HT Insulation tape roll BI01010001010000000000000515BI0100001179 20 Nos
69 53 Taking down unserviceable steel tubular poles at site as directed by Engr-in-charge BI01010001010000000000000515BI0100001180 2 Nos
70 54 Supply and erect in true vertical (or to be planted as strut) steel tubular, swaged welded pole complete with MS base plate of 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolts, nuts, washer and screws confirming to IS -2713 Part II type 410-SP-31 (11 mtr long) hole of required size and Nos for fixing cross arms painting with one coat of red oxide primer and two coats of silver aluminium paint for exposed surface and two coats of black bituminous paint for portion embedded in concrete complete all as specified and directed (Note : Excavation earth work, PCC foundation, coping shall be measured and paid separately). BI01010001010000000000000515BI0100001181 2 Each
71 55 Disconnecting and taking down unserviceable 11 KV UG Cable of any size and capacity BI01010001010000000000000515BI0100001182 80 RM
72 56 Supplying, Laying & testing cable XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size through pipes in ducts, poles/ trenches including fixing of aluminium lugs, making good to disturbed surface etc for the following cross sectional area, complete the following as specified and directed 95 Sqmm 3 core :- Make:- Grandlay/Havells/Polycab\n(Note : Excavation and earth work to be measured and paid separately) BI01010001010000000000000515BI0100001183 80 RM
73 57 S&F as in replacement of Anti climbing devices; spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers, and welding in two halves made to shape to suit the cross section of the pole. BI01010001010000000000000515BI0100001184 1 Qtl
74 58 M&L in replacement of unserviceable danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figure and conventional skull and bone signal in red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 25x20 cm Size BI01010001010000000000000515BI0100001185 5 Each
75 59 M&L in replacement of unserviceable Guardiing Cradles,hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia BI01010001010000000000000515BI0100001186 1 Qtl
76 60 S & as in replacement of selector switch suitable for capacitor bank including all connecting/joining materials as required complete all as specified and directed. BI01010001010000000000000515BI0100001187 8 Each
77 61 S&F potential transformer suitable for VCB 630 Amps, Accuracy class 1.0 of make : ABB earthed type, 11000/V3/110/V/110/V3-110/3V BI01010001010000000000000515BI0100001188 1 Set of 3
78 62 M&L for Providing & application of DELTA Cleaner,on claims / joints 11KV Anti-moisture coating & Protective coating (for protection from pollution, acid fumes, carbon formation, loosening of joints etc) at selected six places in 11 KV MRS sub stn No.1 BI01010001010000000000000515BI0100001189 1 Each Job
79 63 Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed. BI01010001010000000000000515BI0100001190 3.87 per 1000
80 64 M&L for PCC 1:4:8) type D-2 using 40mm graded stone aggregate in foundation of PCC poles/struts as specified including necessary form work all as specified and directed. BI01010001010000000000000515BI0100001191 1.8 Cum
81 65 M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. BI01010001010000000000000515BI0100001192 1.5 Cum
82 66 Labour only for stringing, tightening, fixing and connecting ACSR conductor and GI Wire of existing HT/LT overhead line any size any type, between pole to pole, approximate span length 40 to 50m, complete the following all as specified and directed : -\n(i) 2 Wire with/Without GI Wire. BI01010001010000000000000515BI0100001193 20 Each Span
83 66.01 (ii) 5 Wire With GI Wire. BI01010001010000000000000515BI0100001194 40 Each Span
84 66.02 (iii) 6 Wire With GI Wire. BI01010001010000000000000515BI0100001195 20 Each Span
85 67 M & L for prunning of tree branches of any sizes and dia, not less than 2 Mtr around the LT /HT OH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area and testing of line, complete all as specified and directed.\nNote : (i) Span length is aproximate 40 to 50m.\n(ii) Rate quoted are inclusive of repair to damage work in item. BI01010001010000000000000515BI0100001196 100 Each Span
86 68 Earthing complete with galvanized steel earth plate electrodes 60x60x6 mm thick buried directly in ground eath (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanized iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvnised iron or steel all as specified &shown in electrical plate No.3 of MES SSR part-I connected to earth test point as specified as specified and testing on completion including provision of 40 mm dia light grade pipe & watering pipe shall be 20 mm bore meadium grade including all excavation & earth work in any type of soil incl PCC for pit (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including chrcoal , salt funnel GI pipe 40 mm dia light grade up to to 7.5 mtr length ,all as directed at site. BI01010001010000000000000515BI0100001197 2 Each Set
87 69 M&L for Painting single pole or struct of LT PCC poles/structure including. cleaning and scrapping the old surface and then applying two coat of light grey synthetic enamel paint to complete pole and two coat of aluminum synthetic enamel paint over a coat of red oxide on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc and including painting of pole/ structure with two coat of synthetic paint yellow & Black strips 300mm wide alternative from bottom to upward of LT pole upto height of 1.5mtr above embedded portion at GL, and writing pole number, complete the following as specified and directed by EIC. BI01010001010000000000000515BI0100001198 5 Each Job
88 70 M&L for Painting of single LT steel tubular, structure including. cleaning and scrapping the old surface and then applying two coat of aluminium synthetic enamel paint over a coat of red oxide primer on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc. and including painting of pole/ structure ith two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete the following as specified and directed :-\nNotes for Item No 70 to 71: - \n(i) Pole will be cleaned with steel brush to remove old unserviceable paint or scrapped complete surface.\n(ii) All poles will be numbered all as directed at site.\n(iii) If painting of poles not properly and not satisfied by JE/Engr-in-charge shall not be paid to contractor or otherwise repaint without extra cost. BI01010001010000000000000515BI0100001199 140 Each
89 71 Supplying, Laying, Jointing, testing and commissioning cable XLPE insulated armoured LT 1100 grade heavy duty with Stranded aluminum conductor through pipes in ducts, poles/ trenches including fixing of copper lugs, making good to disturbed surface etc for the following cross sectional area, complete the following as specified and directed :- Make:- Grandlay/Havells/Polycab\n(Note : Excavation and earth work to be measured and paid separately)\n(i) 10 Sqmm 2 core BI01010001010000000000000515BI0100001200 170 RM
90 71.01 (ii) 25 Sqmm 3.5 core BI01010001010000000000000515BI0100001201 70 RM
91 71.02 (iii) 35 Sqmm 3.5 core BI01010001010000000000000515BI0100001202 70 RM
92 71.03 (iv) 50 Sqmm 3.5 core BI01010001010000000000000515BI0100001203 70 RM
93 71.04 (v) 70 Sqmm 3.5 core BI01010001010000000000000515BI0100001204 60 RM
94 71.05 (vi) 95 Sqmm 3.5 core BI01010001010000000000000515BI0100001205 60 RM
95 72 Taking down GI tubing light grade of sizes 50/40 mm dia from trenches/floor/walls/poles, complete all as specified and directed.\n(Note : Excavation will be measured and paid separately). BI01010001010000000000000515BI0100001206 26 RM
96 73 S&F GI tubing 50mm bore light grade for cable protection fixed on pole/laid under floor / road/wall etc with fittings including necessary flat iron clamps of size 40 x5 mm etc complete all as specified and directed. BI01010001010000000000000515BI0100001207 8 RM
97 74 S&F GI tubing 40mm bore light grade for cable protection fixed on pole/laid under floor/wall etc with fittings including flat iron clamp 40 x 5 mm complete all as specified and directed. BI01010001010000000000000515BI0100001208 18 RM
98 75 M&L for replacement of unserviceable/ damaged PVC jumper for HT/LT of any size and length to transformer or pole for making connection, complete all as specified and directed. BI01010001010000000000000515BI0100001209 30 Each Job
99 76 S&F aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. BI01010001010000000000000515BI0100001210 15 RM
100 77 M&L cutting PCC/floor/road and taking out cable and making good with PCC including material as per existing after laying of pipe for cable protection complete all as specified and directed at site of trench not more than 0.30 x 0.30m, complete all as specified and directed. BI01010001010000000000000515BI0100001211 6 RM
101 78 Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, 10 x 2 core cable flat or circular complete all as specified and directed. BI01010001010000000000000515BI0100001212 45 RM
102 79 Taking down MCCB of any capacity and size, complete all as specified and directed. BI01010001010000000000000515BI0100001213 9 Each
103 80 Supply and fixing MCCB 400 Amp 4 pole 36 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4202 07/ Siemens/ Schneider BI01010001010000000000000515BI0100001214 1 Each
104 81 Supply and fixing MCCB 250 Amp 4 pole 25 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4202 19/ Siemens/ Schneider BI01010001010000000000000515BI0100001215 3 Each
105 82 Supply and fixing MCCB 200 Amp 3 pole 25 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4202 08/ Siemens/ Schneider or equivalent BI01010001010000000000000515BI0100001216 2 Each
106 83 Supply and fixing MCCB 160 Amp 4 pole 16 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4200 17/ Siemens/ Schneider or equivalent BI01010001010000000000000515BI0100001217 1 Each
107 84 Supply and fixing MCCB 100 Amp 4 pole 16 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4200 15/ Siemens/ Schneider BI01010001010000000000000515BI0100001218 1 Each
108 85 Supply and fixing MCCB 63 Amp 4 pole 16 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4200 13/ Siemens/ Schneider BI01010001010000000000000515BI0100001219 1 Each
109 86 Supply and fixing set of incoming or outgoing spreaders 4P complete all as specified and directed. Make;- Legrand catpart No 4200 13/ Siemens/ Schneider BI01010001010000000000000515BI0100001220 1 Set
110 87 M&L for repairing LT feeder box/ panel and their doors, inner compartments etc by denting/ welding where required and cleaning, removing old paint by paint remover/scrappers for any number of coats, any width or girth and applying two coats of synthetic enamel paint by spray painting, inside and outside of panels(second coat shall be applied at the interval of one day) of the approved colour, complete all as specified and directed. BI01010001010000000000000515BI0100001221 6 Each Job
111 88 M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones signal in red colour and fixed with M.S. Clamp 25X3mm, suitable for PCC/Steel tubular pole, bolts and nuts of approved size for LT 20x15 cm size complete. BI01010001010000000000000515BI0100001222 20 Each
112 89 Supply and labour for spreading stone aggregate of size 40mm at 11 KV sub station/Transformer/panel board/two pole/four pole structure area, complete all as specified and directed. BI01010001010000000000000515BI0100001223 2 Cum
113 90 S&F in replacement LED type Indicating lamps for LT panel, RYB colour, complete all as specified and directed. BI01010001010000000000000515BI0100001224 12 Each Set
114 91 Supply and fixing in repair microrex T31 analog time switch in accordance with IEC 60730-1, automatic ON/OFF, +/- 5 min for the daily time switch -10 degree C to +55 degree C temperature complete all as specified and directed. Make:- Legrand cat part No 4128 12/ Havells/ C&S BI01010001010000000000000515BI0100001225 1 Each
115 92 Supply and fixing new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 45 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make:- Cat Part No LTESS45WLED/LS of C&S or equivalent in Havells/CG/Phillips BI01010001010000000000000515BI0100001226 2 Each
116 93 Supply and fixing new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 25 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make:- Cat Part No LTESS25WLED/LS of C&S or equivalent in Havells/CG/Phillips BI01010001010000000000000515BI0100001227 2 Each
117 94 Supply and fixing in repair for swich disconnector fuse unit in sheet steel enclosure TPN current rating 160 Amp with HRC Fuse including disconnecting and taking out U/S Main switch complete all as specified and directed. BI01010001010000000000000515BI0100001228 1 Each
118 95 Supply and fixing in repair for swich disconnector fuse unit in sheet steel enclosure TPN current rating 100 Amp with HRC Fuse including disconnecting and taking out U/S Main switch complete all as specified and directed. BI01010001010000000000000515BI0100001229 1 Each
119 96 M&L for pin insulator porcelain type vitreous white brown including one galvanized mild steel spindle two galvanize iron washers and one galvanized iron nut 100 mm height, 65mm dia for 1100 V grade, complete all as specified and directed. BI01010001010000000000000515BI0100001230 35 Each
120 97 M&L for shackle type porcelain vitreous white, brown including one galvanized mild steel straps, washers, bolts and nuts 100 mm height, 115 mm dia, section of strap 31 x 5 mm for 1100 V grade, complete all as specified and directed. BI01010001010000000000000515BI0100001231 20 Each
121 98 Dismantling unserviceable insulators any type, any size, complete all as specified and directed. BI01010001010000000000000515BI0100001232 55 Each
122 99 M&L in repair for LT line PVC Spacers spiral type for the following :-\n(i) Spacer for two wire BI01010001010000000000000515BI0100001233 40 Each
123 99.01 (ii) Spacer for three wire BI01010001010000000000000515BI0100001234 50 Each
124 99.02 (iii) Spacer for four wire BI01010001010000000000000515BI0100001235 100 Each
125 100 M&L for replacement of unserviceable/ damaged PVC jumper for LT of any size and length to transformer or pole for making connection, complete all as specified and directed. BI01010001010000000000000515BI0100001236 30 Each Job
126 101 Dismantling/taking out old unserviceable LT of PCC/Steel poles after breaking the PCC foundation and clearing the site/premises complete all as specified and directed. BI01010001010000000000000515BI0100001237 2 Each
127 102 Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts , nuts and screw as specified of type 410 SP-31, 9 Meter long, including marking alternate yellow and black strips 30 cm height- total-5Nos with two coats of aluminium paint over a coat of zinc chrome primer above embedded portion at GL, complete all as specified and directed.\n(Note. Earth work and PCC for foundation channels, clamps, nuts and bolts to be measured and paid for separately) BI01010001010000000000000515BI0100001238 2 Each
128 103 Dismentling of ACSR conductor, service feeder or distribution spans complete all as directed. BI01010001010000000000000515BI0100001239 4 Qtl
129 104 Supplying, Stringing, Tightening, Fixing & connecting ACSR conductor of any size for over Head LT Line including aluminium binding wire or aluminium tape of suitable type clamps/connector or other jointing material complete all as specified and directed by EIC. BI01010001010000000000000515BI0100001240 4 Qtl
130 105 M & L for galvanised steel wire 4 mm dia to be stringed as continuous earthing wire on over head LT lines complete all as directed incl taking down the old rusted earth wire. BI01010001010000000000000515BI0100001241 2.5 Qtl
131 106 Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified. BI01010001010000000000000515BI0100001242 0.5 Qtl
132 107 M&L for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all as specified and directed by EIC. BI01010001010000000000000515BI0100001243 0.5 Qtl
133 108 Supply and fixing in repairs stay assembly for LT Pole comprising of 7/3.15mm galvanized steel stranded stay wire of required length fixed to pole with and including clamps fabricated out of MS Clamps 50 x 6 mm flat iron including nuts, bolts and washers, MS galvanized stay bow 14mm dia 400mm long galvanized steel stay rod 16mm dia, 1800mm long with ratchet type nuts & bolts and stay plate, galvanized thimble 02 Nos, loop insulators 65mm x90mm clearance dia of hole 16mm all as specified and shown in electrical plate No. 1 of MES SSR including all necessary excavation and earth work, PCC (1:3:6) type C-2 using 40mm graded stone aggregate ,embedded block and disposal of surplus soil to a distance not exceeding 50mtr complete all as specified and directed by EIC. BI01010001010000000000000515BI0100001244 3 Each Set
134 109 Earthing complete with galvanized steel earth plate electrodes 60x60x6 mm thick buried directly in ground eath (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to GI wire 4mm by means of bolt nuts check nuts and washers of galvnised iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I connected to earth test point as specified as specified and testing on completion including provision of 20 mm dia light grade pipe & watering pipe shall be 15 mm bore meadium grade including all excavation & earth work in any type of soil incl PCC for pit (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including chrcoal, salt & funnel GI pipe 20 mm dia light grade up to to 7.5 mtr length ,all as directed at site. BI01010001010000000000000515BI0100001245 4 Each Set
135 110 Repairs to existing stay assembly including tightening of stay wire, , shifting of clamps fixed to pole or by repairing to PCC coping by breaking and making new with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and directed at site . BI01010001010000000000000515BI0100001246 4 Each Job