Supply And Fixing Of High Mast Light At Various Place , Ratangarh, WORK-Rajasthan

Department Of Local Bodies has published Supply And Fixing Of High Mast Light At Various Place , Ratangarh. Submission Date for this Tender is 09-10-2020. Luminaires Tenders in WORK Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

25573255
Supply And Fixing Of High Mast Light At Various Place , Ratangarh
Open Tender
Indian
Rajasthan
WORK
09-10-2020

Tender Details

Supply And Fixing Of High Mast Light At Various Place , Ratangarh , Supply , Erection Testing And Commissioning Of High Mast Lighting System ( As Per Cp3-Trt/1996 Of Ile , Uk ) Consisting Of Totally Hot Dip Galvanised By Single Dipped Method High Mast , Lantern Carriage Suitable For Up To 12 Nos Luminaries , Mast Head Assembly , Two Nos Aviation Obstruction Neon Lights , Double Drum Type Self Sustaining Winch , Integral Power Tool ( Winch Motor With Control Circuit ) Hot Dipped Galvanised Heavy Duty Pipe Lightening Finial , Suitable Ropes And Cc Foundation Of M-15 Grade Complete As Required . The Mast Is Constructed From Mild Steel Plates ( As Per Bs-En 10025 ) Cut And Folded To Form A Polygonal Section , Telescopic Jointed And Welding As Per Bs 5135 . The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply , Erection , Testing And Commissioning Of High Mast . With All Accessories , Which Also Includs Internal Electrical Cable And Panel With Foundation , Erection & Commissioning Excluding Luminaries And Lamps 16 Mtr Hm ( In 2 Section ) G-2 , P & F Of Ip-66 Protected High Power Led Flood LightSystem With Extruded Aluminium Housing , ToughenedGlass Diffuser With Suitable Lenses On Led To AchieveVarious Beam Angles , 240 Volt , 50Hz , Of High Power LedLamps Supplied With Pre Wired Cable Of 1 Mtr . IntegratedDriver Shall Be High Efficiency Having Efficiency MoreThan 85 % And In Compliance To Iec Standards . SystemLife Of 50000 Burning Hours With 70 % Of Initial Lumen BeMaintained . Light Output In Red , Green , Blue , Cool WhiteOr Warm White Colour As Per Engineers Choice . FixturesShall Be Ce Compliance 110-120 Watt . , Providing & Laying Xlpe Insulated / P . V . C . SheathedCable Of 1 . 1 Kv Grade With Aluminium ConductorArmoured Of Is:7098-I/1554-1 Approved Make InGround As Per Is:1255 Including Excavation Of30Cmx75cm Size Trench , 25 Cm Thick Under Layer OfSand , Second Class Bricks Covering , Refilling Earth , Compaction Of Earth , Making Necessary Connection , Testing Etc . As Required Of Size 6 Sq . Mm 2 Core , Providing & Laying Xlpe Insulated / P . V . C . SheathedCable Of 1 . 1 Kv Grade With Aluminium ConductorArmoured Of Is:7098-I/1554-1 Approved Make InGround As Per Is:1255 Including Excavation Of30Cmx75cm Size Trench , 25 Cm Thick Under Layer OfSand , Second Class Bricks Covering , Refilling Earth , Compaction Of Earth , Making Necessary Connection , Testing Etc . As Required Of Size . 35 Mm Sq . 4 Core , P&F 240/415 V Mcb Of Breaking Capacity Not Less Than10 Ka ( B/ C/ D Tripping Characteristic ) Isi Marked Is8828 ( 1996 ) ]/ Conforming To Iec 60898 In ExistingBoard/Sheets Including Making Connections With Lugs , Testing Etc . As Required . 32 Amp , P&F 240/415 V Mcb Of Breaking Capacity Not Less Than10 Ka ( B/ C/ D Tripping Characteristic ) Isi Marked Is8828 ( 1996 ) ]/ Conforming To Iec 60898 In ExistingBoard/Sheets Including Making Connections With Lugs , Testing Etc . As Required . 63 Amp , Providing & Laying Xlpe Insulated / P . V . C . SheathedCable Of 1 . 1 Kv Grade With Aluminium ConductorArmoured Of Is:7098-I/1554-1 Approved Make InGround As Per Is:1255 Including Excavation Of30Cmx75cm Size Trench , 25 Cm Thick Under Layer OfSand , Second Class Bricks Covering , Refilling Earth , Compaction Of Earth , Making Necessary Connection , Testing Etc . As Required Of Size . 16Sqm Mm 4 Core , Plate Earthing As Per Is:3043 With Copper Earth Plate Of Size600Mm X 600Mm X 3 . 0Mm By Embodying 3 To 4 Mtr . Below TheGround Level With 20 Mm Dia . G . I . B Class Watering Pipe Including AllAccessories Like Nut , Bolts , Reducer , Nipple , Wire Meshed Funnel , AndC . C . Finished Chamber Covered With Hinged Type With LockingArrangement C . I . Cover , C . I . Frame Of Size300mm X 300MmComplete With Alternate Layers Of Salt And Coke/Charcoal , Testing OfEarth Resistance As Required . , S & Laying Following Size Earth Wire/Strip In Horizontal Or Vertical RunIn Ground/Surface/Recess Including Riveting , Soldering , Saddles , Making Connection Etc . As Required . , P&F Recessed/ Surface Mounting Heavy Duty VerticalType Sheet Steel Distribution Board With Provision OfIncomer , Phophatised , Powder Painted Complete With100 A Insulated Copper Bus Bar , Neutral Link , Earth LinkAnd Din Bar , Conforming To Is13032 & Is8623 IncludingMaking Internal Db Terminations With Copper Lugs , Testing Etc . As Required . 3 Phase 8 Way , P&F Of Mechanical / Digital Time Switch Having Following Day / WeekProgramme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection , Programming Etc . AsRequired . 32 A Rating

Key Value

Document Fees
INR 1000 /-
EMD
INR 49975.0 /-
Tender Value
INR 24.98 Lakhs /-

BOQ Items

Name of Work: SUPPLY AND FIXING OF HIGH MAST LIGHT AT VARIOUS PLACE, RATANGARH
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, erection testing and commissioning of high mast lighting system (as per CP3-TRT/1996 of ILE, UK) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries, mast head assembly, two nos aviation obstruction neon lights, double drum type self sustaining winch, integral power tool( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes and CC foundation of M-15 grade complete as required. The mast is constructed from mild steel plates (as per BS-EN 10025) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. with all accessories, which also includs internal electrical cable and panel with foundation, erection & commissioning excluding luminaries and lamps 16 Mtr HM (in 2 section) G-2 BI01010001010000000000000515BI0100001113 5 cum
2 2 P & F of IP-66 protected high power LED flood light\nsystem with extruded aluminium housing , toughened\nglass diffuser with suitable lenses on LED to achieve\nvarious beam angles, 240 volt, 50Hz, of high power LED\nlamps supplied with pre wired cable of 1 mtr. Integrated\ndriver shall be high efficiency having efficiency more\nthan 85 % and in compliance to IEC standards. System\nlife of 50000 burning hours with 70 % of initial lumen be\nmaintained. Light output in red , green , blue, cool white\nor warm white colour as per engineers choice. Fixtures\nshall be CE compliance 110-120 watt. BI01010001010000000000000515BI0100001114 30 cum
3 3 Providing & Laying XLPE insulated / P.V.C. sheathed\ncable of 1.1 KV grade with aluminium conductor\nArmoured of IS:7098-I/1554-1 approved make in\nground as per IS:1255 including excavation of\n30cmx75cm size trench, 25 cm thick under layer of\nsand, second Class bricks covering, refilling earth,\ncompaction of earth, making necessary connection,\ntesting etc. as required of size 6 sq.mm 2 core BI01010001010000000000000515BI0100001115 425 cum
4 4 Providing & Laying XLPE insulated / P.V.C. sheathed\ncable of 1.1 KV grade with aluminium conductor\nArmoured of IS:7098-I/1554-1 approved make in\nground as per IS:1255 including excavation of\n30cmx75cm size trench, 25 cm thick under layer of\nsand, second Class bricks covering, refilling earth,\ncompaction of earth, making necessary connection,\ntesting etc. as required of size. 35 mm sq. 4 core BI01010001010000000000000515BI0100001116 325 cum
5 5 P&F 240/415 V MCB of breaking capacity not less than\n10 KA (B/ C/ D tripping characteristic) ISI marked IS\n8828(1996)]/ conforming to IEC 60898 in existing\nboard/sheets including making connections with lugs,\ntesting etc. as required. 32 amp BI01010001010000000000000515BI0100001117 40 cum
6 6 P&F 240/415 V MCB of breaking capacity not less than\n10 KA (B/ C/ D tripping characteristic) ISI marked IS\n8828(1996)]/ conforming to IEC 60898 in existing\nboard/sheets including making connections with lugs,\ntesting etc. as required. 63 amp BI01010001010000000000000515BI0100001118 15 cum
7 7 Providing & Laying XLPE insulated / P.V.C. sheathed\ncable of 1.1 KV grade with aluminium conductor\nArmoured of IS:7098-I/1554-1 approved make in\nground as per IS:1255 including excavation of\n30cmx75cm size trench, 25 cm thick under layer of\nsand, second Class bricks covering, refilling earth,\ncompaction of earth, making necessary connection,\ntesting etc. as required of size. 16sqm mm 4 core BI01010001010000000000000515BI0100001119 400 sqm
8 8 Plate Earthing as per IS:3043 with copper Earth plate of size\n600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the\nground level with 20 mm dia. G.I. 'B' class watering Pipe including all\naccessories like nut, bolts, reducer, nipple ,wire meshed funnel, and\nC.C. finished chamber covered with hinged type with locking\narrangement C.I. Cover, C.I. Frame of size300mm x 300mm\ncomplete with alternate layers of salt and coke/charcoal, testing of\nearth resistance as required. BI01010001010000000000000515BI0100001120 5 kg
9 9 S & Laying following size earth wire/strip in horizontal or vertical run\nin ground/surface/recess including riveting, soldering, saddles,\nmaking connection etc. as required. BI01010001010000000000000515BI0100001121 1000 sqm
10 10 P&F recessed/ surface mounting heavy duty Vertical\ntype sheet steel Distribution board with provision of\nincomer, phophatised ,powder painted complete with\n100 A insulated copper bus bar , neutral link, earth link\nand din bar, conforming to IS13032 & IS8623 including\nmaking internal DB terminations with copper lugs ,\ntesting etc. as required. 3 phase 8 way BI01010001010000000000000515BI0100001122 5 sqm
11 11 P&F of mechanical / digital time switch having following day / week\nprogramme and minimum 100 hours reserve and AC1 rating of 16-\n20 amperes including making connection, programming etc. as\nrequired. 32 A rating BI01010001010000000000000515BI0100001123 5 cum