| 1 | 1 | Sch 'A' Sec -I (Building work)\nNote:- This schedule is not pre-priced by MES and the pre-priced rate as \"Rs. 0.00\" indicated under Col.5. signifies this fact only\nConstruction of RUNWAY COTROLLER HUT INCL TOILET with permanent specification complete all as specified and shown in drawing. | | 1 | Each |
|---|
| 2 | 2 | Total amount of Sch 'A' Part-II INTERNAL ELECTRIC SUPPLY )\nPrepriced amount B/F from Sl page No. 24 | | 1 | Lump sum |
|---|
| 3 | 3 | Total amount of Sch 'A' Part-III (INTERNAL WATER SUPPLYT) \nPrepriced amount B/F from Sl page No. 26 | | 1 | Lump sum |
|---|
| 4 | 4 | Total amount of Sch 'A' Part-IV (LIGHTING PROTECTION ) \nPrepriced amount B/F from Sl page No. 27 | | 1 | Lump sum |
|---|
| 5 | 5 | Total amount of Sch 'A' Part-V( SEWAGE DISPOSAL) \n Prepriced amount B/F from Sl page No. 29 | | 1 | Lump sum |
|---|
| 6 | 6 | Total amount of Sch 'A' Part-VI( AC AND REFRIGERATION) \nPrepriced amount B/F from Sl page No. 31 | | 1 | Lump sum |
|---|
| 7 | 7 | Total amount of Sch 'A' Part-VII (EXTERNAL ELECTRIC SUPPLY )\nPrepriced amount B/F from Sl page No. 32 | | 1 | Lump sum |
|---|
| 8 | 8 | Total amount of Sch 'A' Part-VIII (EXTERNAL WATER SUPPLY ) \n Prepriced amount B/F from Sl page No. 33 | | 1 | Lump sum |
|---|
| 9 | 9 | Total amount of Sch 'A' Part-IX (SPECIAL ITEMS )\nPrepriced amount B/F from Sl page No. 34 | | 1 | Lump sum |
|---|
| 10 | 10 | Sch 'A' Part-X (Misc Items)\nNote:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.5 signifies this fact only. | | | |
|---|
| 11 | 11 | S&Fstainless steel toilet paper holder of fixed to walls in steel screws complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 12 | 12 | S&F stainless steel soap dish of vitreiou china, white size 60mmx160mmx90mm embedded to wall complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 13 | 13 | M&L for 10 user RCC hume pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 14 | 14 | Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2M dia X 3.0 M effective depth, complete all as specified and as shown on TD DRG Ref AF/TD/STRU/236 sheet 1/2 & 2/2 as specified. | | 1 | Each |
|---|
| 15 | 15 | Cutting GI main pipes of dia 80 mm and reducing to required length in position for insertion of new Tee, branches etc complete all as specified and directed by Engr-in-charge. | | 1 | Each job |
|---|
| 16 | 16 | M&L for Construction of brick massonry valve pit chamber of inner dimension 120x120x120 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolished old valve pit complete all as specified and directed by Engr-in-charge.\n | | 1 | Each job |
|---|
| 17 | 17 | S & F Thermoplastic weather proof empty box (IP 65) with plane wall of size 300mm (L) X 150mm (B) X 170mm (H) fixed on wall with provision of nut, bolts, washer etc. including fixing of test point terminal block inside the box which made out of gun metal or phosphorous bronze of size 75mm X 75mm X 25 mm, drilled and screwed including 3 Nos 8mm dia 25 mm long hex Head screw including taking down old unserviceable one complete all as specified and directed by Engr-in-charge.\n | | 6 | Each |
|---|
| 18 | 18 | Supply & Installation of Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED( 80-100)microns with pure Zinc (99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3034. The outer and inner pipe should be 76.2 mm & 41.9 mm 3mtrs Length, Zinc coated with additional special Alloy coating 300mm on the topside for additional corrosion protection of the Terminal. The annular space between the pipes being filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity The job includes digging the pits and refilling the same by Electrodite/Conductolite Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having RoHS Certification from NABL accredited lab. Good earth is to be arranged to fill the excavated pits by mixing the same with BFC 2 bags. including PCC pit in cement concrete 1:3:6 (20mm graded stone aggregate) and RCC cover of size 450 x 450 x50mm in RCC 1:2:4 (20mm Graded stone aggregate) reinforced with and including 8.0mm dia TMT bars @ 100mm centre to centre both ways complete all as specified and directed by Engr-in-charge. | | 3 | Each job |
|---|
| 19 | 19 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR .Make- voltas/ carrier or any equivalent .all complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 20 | 20 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA . Make- volina or any equivalent all complete all as specified and directed by Engr-in-charge. Make- volina or any equivalent make.\n | | 2 | Each |
|---|
| 21 | 21 | Supply and fixing MCB SP C curve 6-32Amp, 240 Volt, 10 KA.as per ISI marked IS/IEC 60898-1 2002.CAT PART NO- 4085 93 all complete all as specified and directed by Engr-in-charge. MAKE- Legrand OR equivalent | | 2 | Each |
|---|
| 22 | 22 | Supply and fix oil filled radiater/ heat convector with capacity of 2500W complete all as specified and directed by Engr-in-charge. Make- HAVELLS. MODEL:-OFR-9 FIN 2000W, GHR0FAEK240 \n | | 1 | Each |
|---|
| 23 | 23 | Supply and fix Table Lamp of capacity 25 W of any all complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 24 | 24 | Supply and fix dimmer for table lamp all complete all as specified and directed by Engr-in-charge.\n | | 1 | Each Job |
|---|
| 25 | 25 | Supply and fix integral LED aviation light comprising of aluminium housing with polycarbonate enclosure. Including pipe of 15mm dia and up to 1 metre length with pcc foundation of dimensions 0.3m x03mx0.3m of type B2 1:2:4. complete all as specified and directed by Engr-in-charge.Make-Bajaj. Part n0-110731 \n | | 1 | Each |
|---|
| 26 | 26 | S & F Distribution board, VTPN, 6 way, vertical type, double door, 415 volts with provision for DPX 125 MCCB as incommer and SP/TP MCB as outgoing and electrically connecting upcomplete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 27 | 27 | Supply and fix MCCBs, 63 Amps, 16 KA, 4 pole with adjustable thermal & magnetic settings complete all as specified and directed by Engr-in-charge.\n | | 1 | Each |
|---|
| 28 | 28 | M&L for MCB single pole, 240 volts, 6 - 32 Amps, 10 KA. complete all as specified and directed by Engr-in-charge.\n | | 12 | Each |
|---|
| 29 | 29 | S&F Exhaust fan of 300 mm sweep including making hole in the brick wall, complete with all fixing arrangements viz mild steel bolts, nuts etc and electrical connection with round three core PVC insulated 1.50sqmm copper conductor from ceiling rose to Exhaust fan complete all as specified and directed by Engr-in-charge.\n | | 1 | Each |
|---|
| 30 | 30 | Supply and fix 20 watt LED light with batten for LED tube light, suitable for single phase 230 Volts, 50 Hz AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with r cable of size 0.5 Sqmm (nominal area) complete all as directed by Engr-in-charge. | | 5 | Each |
|---|
| 31 | 31 | Supply and fix 25 Watt LED building security light fitting, pressure die-cast aluminium roadway luminaire with high powered LED, electronic driver, pressure die cast housing with epoxy powder coated dark graphite grey colour finish. prismatic polycarbonate cover with individual LED lenses, IP 65, complete all as directed by Engr-in-charge. | | 4 | Each |
|---|