| 1 | 1 | Demolition of stone boulder any description complete all as specified and directed by Engr-in-Charge. | | 12 | Cum |
|---|
| 2 | 2 | Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 cm thickness below or above ground level, complete all as specified and directed by Engr-in-Charge. | | 41 | Cum |
|---|
| 3 | 3 | Demolition of brick or stone/concrete blcok/stone boulder masonry built in cement mortar including all quions, arches, pillars etc., but excluding ashlar facings, dressed stone works and precast cement articles, complete all as specified and directed by Engineer-in-charge. | | 2.5 | Cum |
|---|
| 4 | 4 | Precast cement concrete block masonry type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) with solid blocks exceeding 10cm in width and set in cement mortar 1:4, complete all as specified and directed by Engineer-in-charge. | | 22 | Cum |
|---|
| 5 | 5 | M & L for rendering 15mm thick on fair faces of brick work or concrete surface finished even and smooth without using extra cement in cement mortar (1:4). | | 106 | Sqm |
|---|
| 6 | 6 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engr-in-Charge. | | 80 | Sqm |
|---|
| 7 | 7 | Rendering 15 mm thick in cement mortar 1:6, on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge. | | 60 | Sqm |
|---|
| 8 | 8 | Prepration of new plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed by Engr-in-Charge. | | 176 | Sqm |
|---|
| 9 | 9 | Prepration of old plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed by Engr-in-Charge. | | 150 | Sqm |
|---|
| 10 | 10 | M&L for 75mm thick, plain cement concrete ,1:3:6, type C-2, (using 40mm graded crushed stone aggregate) as in sub base flooring, surface finished even, complete all as specified and directed by Engr-in-Charge. | | 236 | Sqm |
|---|
| 11 | 11 | M&L for Non-skid coloured ceramic tiles, 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38sqm, in floors etc, set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over including 15 mm thick screed bead in CM 1:4, complete all as specified and directed by Engr-in-Charge. | | 308 | Sqm |
|---|
| 12 | 12 | M & L for Glazed ceramic coloured tiles of size 300x200x7 mm thick on vertical surface such as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 10 mm thick rendering in CM (1:4), complete all as specified and directed by Engr-in-Charge. | | 21 | Sqm |
|---|
| 13 | 13 | M & L for 75 mm thick, plain cement concrete, type C-1, 1:3:6, (using 20mm graded stone aggregate) as in plinth protection including finishing surface even and smooth complete all as specified and directed by Engr-in-Charge. | | 133 | Sqm |
|---|
| 14 | 14 | M&L Cement concrete type B0(1:2:4) 12.5 mm graded aggregate all as specified 25mm thick in floor | | 308 | Sqm |
|---|
| 15 | 15 | Dismantling of timber scantling of any description, 40 sqcm and over in section, in any position as in unframed work, complete all as specified and directed by Engr-in-Charge. | | 2.85 | Cum |
|---|
| 16 | 16 | M&L for Second class soft wood (KAIL), clean sawn timber scantlings as in purlins, rafters, form work etc, complete all as specified and directed by Engr-in-Charge | | 2.85 | Cum |
|---|
| 17 | 17 | Dismantling of plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engr-in-Charge. | | 778 | Sqm |
|---|
| 18 | 18 | S&F 0.63mm thick, galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L type of J type or crancked hook bolts and washers and washers, in roofs, walls etc, with grade of zinc coating 275, complete all as specified and directed by Engr-in-Charge | | 685 | Sqm |
|---|
| 19 | 19 | S&F CGI sheeting 0.63mm thick plain, galvanised, mild steel sheeting in ridges, hips, valley gutters, drip and staingy flashing (length and girth as fixed) with grade of zinc coating 275. complete all as specified and directed by Engr-in-Charge. | | 43 | Sqm |
|---|
| 20 | 20 | S & F 2 mm thick, Fibre glass reinforced translucent corrugated sheeting with two corrugations side laps fixed with L-type or J-type or cranked hook bolts in lieu of screews as in roof and walls, complete all as specified and directed by Engr-in-Charge. | | 50 | Sqm |
|---|
| 21 | 21 | Taking down chowkats or frame shutter(without taking off shutter from the frame but exc 1.5 sqm but n.exc 4 Sqm | | 14 | Each |
|---|
| 22 | 22 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs /blankets, any thickness, including cover fillets, complete all as specified and directed by Engr-in-Charge. | | 609 | Sqm |
|---|
| 23 | 23 | Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40 Sqcm, in any position as in unframed work, complete all as specified and directed by Engr-in-Charge. | | 1320 | RM |
|---|
| 24 | 24 | Hacking out old broken glass (any thickness,size,quality or description ) from wooden frames | | 15 | Sqm |
|---|
| 25 | 25 | S&F Plain fillets of second class soft wood (KAIL), wrought, sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm, square, rectangular or triangular in section, secured with nails, complete all as specified and directed by Engr-in-Charge. | | 1250 | RM |
|---|
| 26 | 26 | S&F 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete, all as specified and directed by Engr-in-Charge | | 153 | Sqm |
|---|
| 27 | 27 | S&F in repairs 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber rame work complete, all as specified and directed by Engr-in-Charge | | 458 | Sqm |
|---|
| 28 | 28 | Moulding as in cornices picture rails and the like n exc 6sqcm | | 150 | RM |
|---|
| 29 | 29 | Second class soft wood (KAIL), plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by Engr-in-Charge. | | 0.48 | Cum |
|---|
| 30 | 30 | Second class soft wood (KAIL) plain, framed, panelled shutters (any number of panels), 35 mm thick with panels of 9mm ply BWP commercial type or 12 mm thich of veneered particle board with commercial veneering both faces as in doors, complete all as specified and directed by Engr-in-Charge. | | 24 | Sqm |
|---|
| 31 | 31 | S&F 100 mm butt hinges medim weight cold rolled mild steel fixed with screws or welded complete all as specified and directed by Engr-in-Charge. | | 36 | Each |
|---|
| 32 | 32 | S & F 200 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engr-in-Charge. | | 20 | Each |
|---|
| 33 | 33 | S&F 150mm long, mild steel handles cast type, fitted.complete all as specified and directed by Engr-in-Charge. | | 24 | Each |
|---|
| 34 | 34 | S&F Mild steel sliding door bolt 300 mm long plate type slove enamelled blak wioth bright bolt not less than 12 mm dia with and incl a minimum of 6 bolt and nut four on bolt plate and two on staple plate and fixed, complete all as specified and directed by Engr-in-Charge. | | 16 | Each |
|---|
| 35 | 35 | S & F in repair 4mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 Sqm in each pane, complete all as specified and directed by Engr-in-Charge. | | 15 | Sqm |
|---|
| 36 | 36 | Prepation of new wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel Paint, over a caot of primer, complete all as specified and directed by Engr-in-Charge. | | 52 | Sqm |
|---|
| 37 | 37 | Prepation of old wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel Paint complete all as specified and directed by Engr-in-Charge. | | 30 | Sqm |
|---|
| 38 | 38 | Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, over a coat of red oxide complete all as specified and directed by Engr-in-Charge. | | 675 | Sqm |
|---|
| 39 | 39 | Preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge. | | 180 | Sqm |
|---|
| 40 | 40 | Dismantling structural steel work including doors, gates etc. | | 11.9 | Qtl |
|---|
| 41 | 41 | Rolled mild steel in roof trusses (framed) purlins, crane gantries, rails and fastenings and heavy brackets freming (beams, tee, angle channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde-E-250) quality A, complete all as specified and directed by Engr-in-Charge. | | 1190 | Kg |
|---|
| 42 | 42 | Excavating over areas, n exc 1.5 m deep and getting out in hard / dense soil | | 21 | Cum |
|---|
| 43 | 43 | Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes etc and not exceeding 10 sqm on plan for manholes etc and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge | | 2 | Cum |
|---|
| 44 | 44 | Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engineer-in-charge. | | 2 | Cum |
|---|
| 45 | 45 | Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge. | | 21 | Cum |
|---|
| 46 | 46 | M&L PCC 1:3:6 type C-2 (usingmm graded stone aggregate) in foundation, filling and mass concrete. | | 3.5 | Cum |
|---|
| 47 | 47 | M&L for reinforcement cement concrete (nominal mix) type A1 (1:1:5:3) (using 20mm graded crushed stone aggregate) in foundation , including rafts, footing,foundation beams, plinth beams, bases for coloums etc.complete all as specified and directed by Engr-in-Charge. | | 3.5 | Cum |
|---|
| 48 | 48 | Use and waste form work to sofits of suspended slabs such as roof slabs , floor slabs such as roof slabs, floor slabs, landings and simlar works not exceeding 200m thick, complete all as specified and directed by Engr-in-Charge. | | 13 | Sqm |
|---|
| 49 | 49 | S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings and similar work conforming to Fe-290 Gde E-165 complete all as specified. | | 29 | Kg |
|---|
| 50 | 50 | Supply and fixing mild steel TMT bars 6 mm to 8 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge. | | 290 | Kg |
|---|
| 51 | 51 | S&F 110mm bore pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor , complete all as specified and directed by Engineer-in-charge. | | 12 | RM |
|---|
| 52 | 52 | M&L for providing plain Cement concrete 1:2:4, Type B-1 (using 20 mm graded crushed stone aggregate) as in coping, bed plates, seismic bands, lintels upto 1.5 m clear span, plinth courses and other similar bands, complete all as specified and directed by Engr-in-Charge. | | 0.2 | Cum |
|---|
| 53 | 53 | M&L cement concrete 1:2:4 type B 2 in surface channels and drain. | | 0.25 | Cum |
|---|
| 54 | 54 | Providing precast cement concrete Type B-1 1:2:4 (20 mm graded aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water oughs, mangers, shelves and similar articles with plain frames set in CM1:6 , all as specified and directed. | | 0.35 | Cum |
|---|
| 55 | 55 | M&L for forming fair finishes drain or channel 30 cm inner girth in cement concrete using extra cement all as specified and directed. | | 6 | RM |
|---|
| 56 | 56 | M&L for Granite (of any type) 20mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone incl grinding and polishing over and including 20mm thick bedding layer in CM 1:4,complete all as specified and directed by Engr-in-Charge. | | 6 | Sqm |
|---|
| 57 | 57 | Prepration of old plastered surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed by Engr-in-Charge. | | 40 | Sqm |
|---|
| 58 | 58 | Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. , complete all as specified and directed by Engr-in-Charge. | | 222 | Per Point |
|---|
| 59 | 59 | Point wiring with multistraded copperconductor PVC insulated and unsheathed cable in PVC casing and caping 1.5 Sq mm with all fittings /accessories and including 1.5 Sq mm PVC insulated copper earth wire connected common earth including closed recessed wodden terminal boxes of suitable size made of 2nd class hard wood for mounting of switches,socket setc with 3 mm thick laminated sheet cover for one light point or for one three pin socket outlet 5A or bell/buzzer point independent controlled by one switch , complete all as specified. and directed by Engr-in-Charge | | 200 | Per Point |
|---|
| 60 | 60 | All as per Srl item No 01 here in before but using of cable size 2.5 sq mm for one 3 pin socket outlet 15 Amps switch socket oulet on independent board. | | 22 | Per Point |
|---|
| 61 | 61 | S&F Switch piano 5/6 Amps, single pole one way flush type, complete all as specified and directed by Engr-in-Charge.. | | 122 | Each |
|---|
| 62 | 62 | S&F Switch socket combination 2 in 1, 3 pin, 5/15 Amps Flush type, complete all as specified and directed by Engr-in-Charge. | | 22 | Each |
|---|
| 63 | 63 | S&F Switch socket combination 2 in 1, 3 pin 5 Amps, Flush type, complete all as specified and directed by Engr-in-Charge. | | 78 | Each |
|---|
| 64 | 64 | S&F ceiling rose,surface backlite 65mmx 50mm two or three terminals , complete all as specified. and directed by Engr-in-Charge | | 122 | Each |
|---|
| 65 | 65 | Taking down old MCB DB and M&L for distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated bus bar neutral bar, earth bar, single pole and neutral 240 volts, double door, flush to wall connecting with cable complete all as specified and directed. Make : Legrand, Havells or equivalent. | | 10 | Each |
|---|
| 66 | 66 | S&F Isolator single pole & Nuetral 240 V 40 Amps capacity including suitable size copper Lugs, complete all as specified. and directed by Engr-in-Charge | | 10 | Each |
|---|
| 67 | 67 | S&F MCB single pole 240V AC 6 to 32 Amps 10 KA , complete all as specified. and directed by Engr-in-Charge | | 60 | Each |
|---|
| 68 | 68 | Supply and fixing LED 18 Watt Tubelight fitting decorative ultra slim square profile linear with extruded polycarbonate environment friendly Make Havells Cat part LHEXBTP7IN1W018, complete all as specified and directed by Engr-in-Charge. | | 118 | Each |
|---|
| 69 | 69 | M&L for exhaust fan complete with plastic body, 240 V single phase of size 300 mm sweep incl making hole etc and fixation with 04 nos fully threaded bolt grouted in wall , nut and proding , wire mesh from out side complete with connection, complete including taking down old fan all as specified. and directed by Engr-in-Charge | | 4 | Each |
|---|
| 70 | 70 | Earthing complete with galvanised MS earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mm deep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 3 of SSR of part-I (2009) complete all as specified and directed by Engr-in-charge. | | 3 | Each set |
|---|
| 71 | 71 | Sub main wiring with two single core 2x6 sqmm multistranded copper conductor cable, PVC insulated cable 1100 volts grade and 4.0 Sqmm as continous earthing drawing and including PVC condut, complete all as specified. and directed by Engr-in-Charge | | 73 | RM |
|---|
| 72 | 72 | S&F 1100 Volts grade heavy duty cable PVC insulated aluminium conductor stranded 10 sqmm 2 Core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hagers not more than 1 mtr apart including 4mm suspension wrie one twin core cable flat or circular, complete all as specified. and directed by Engr-in-Charge | | 256 | RM |
|---|
| 73 | 73 | S&F Rectangular PVC block of size 30 x 25 x 5 cm depth, closed recessed. | | 1 | Each |
|---|
| 74 | 96 | M&L House Service bracket (hook type) complete with 3.0 m long G.I pipe 40 mm dia (medium grade), two numbers 90° bends, M.S hook and stay including taking down the existing unserviceable bracket.\nNOTE :- The unit rate shall to include for :-\n(a) Cutting holes in walls etc. of any description, grouting rag bolts and making good with cement mortar 1:3 including making good finishing to match the existing work and removing rubbish off the premises as directed (in case of bracket being fixed to masonry wall).\n(b) G.I pipe house service bracket hook type fabricated out of 3.0m long screwed G.I pipe of medium grade and comprising of two number 90° bend (pipe dia) screwed tight to the top ends of the service vertical limb, the two ends of the service provided with two number of turned spit tight fit, well seasoned teak wood bushing and the bracket fixed plumb vertical against the wall with two number flat iron clamps (fabricated out of 50 x 6mm flat iron with 4 No. 16 mm dia ragged bolts of appropriate size with screwed ends, tightened with 16 mm dia nuts with 6 mm thick washer against the clamp tightening collar. | | 1 | Per \nSet |
|---|
| 75 | 97 | Note:- Deduction for amount of Rs. 1,29,789.00 as listed in Schedule A Part-II (Schedule of credit) shall be made while awarding of contract. | | | |
|---|