Sales : +91-777 804 8217
| Name of Work: ADDN/ALTN TO BLDG NO 2(A) JHANKAR AUDITORIUM, SPL REPAIR TO BLDG NO T - 04 AND PROVN OF STANDBY RESERVE CEILLING FANS, EXHAUST FANS , WALL MOUNTED FANS AND AIR CIRCULATING FANS INCL CERTAIN REVENUE/MINOR WORKS AT DIN MIL STN. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed. | 60 | Sqm | |
| 2 | 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. | 30 | Cum | |
| 3 | 3 | Returning, filling in, including spreading in layers not exceeding 25cm levelling, watering and well ramming as in soft/loose soil complete all as specified and as directed. | 12 | Cum | |
| 4 | 4 | Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. | 27 | Cum | |
| 5 | 5 | M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc. complete all as specified and as directed. | 7.3 | Cum | |
| 6 | 6 | M&L for use and waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed. \n | 40.5 | Sqm | |
| 7 | 7 | M&L for reinforced cement concrete, M-25 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, plinth beams and mass concrete, etc. complete all as specified and as directed.\nNote : Reinforcement shall be measured and paid seperately. | 5.2 | Cum | |
| 8 | 8 | M&L for use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and as directed. | 52.8 | Sqm | |
| 9 | 9 | M&L for reinforced cement concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and as directed.\nNote : Reinforcement shall be measured and paid seperately. | 5.2 | Cum | |
| 10 | 10 | M&L for use and waste Form work to soffits and sides lintel beam, roof beam for flat rough finished surfaces of concrete complete all as specified and as directed. \n | 75 | Sqm | |
| 11 | 11 | M&L for reinforced cement concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and as directed.\nNote : Reinforcement shall be measured and paid seperately. | 6.5 | Cum | |
| 12 | 12 | M&L for use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and as directed. \n | 38 | Sqm | |
| 13 | 13 | M&L Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc. complete, any section straight or winding, but excluding landings; RCC water tanks upto 1500 litres complete all as specified and as directed. | 6.5 | Cum | |
| 14 | 14 | M&L for use & waste Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n. exc. 20cm wide complete all as specified and as directed. | 14 | RM | |
| 15 | 15 | S&F for TMT steel bars 10mm dia. and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. | 2728 | Kg | |
| 16 | 16 | S&F TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in nibs, stirrups, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. | 1205 | Kg | |
| 17 | 17 | M&L for 40 mm thick Damp Proof Course to horizontal or vertical surfaces including necessary form work in cement mortar (1:2) mixed with and including water proofing compound @ 3% or as per manufacturer's instructions including applying evenly two coats of blown type bitumen @1.5 Kg per square meter and blinding with clean dry sand @ 0.05 Cum per Sqm complete all as specified and as directed. \nNote : WPC shall be measured and paid separately. | 8 | Sqm | |
| 18 | 18 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. | 13.7 | Cum | |
| 19 | 19 | M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick) straight or curved on plan exceeding 6.0m mean radius, built in cement mortar (1:4) complete all as specified and as directed. | 32.2 | Cum | |
| 20 | 20 | M&L for Brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exceeding 6.0m mean radius built in cement mortar (1:6) complete all as specified and directed. | 32 | Cum | |
| 21 | 21 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4), mixed with integral water proofing compound weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed.\nNote : WPC shall be measured and paid separately. | 208 | Sqm | |
| 22 | 22 | Supply only integral water proofing compound (ISI marked) complete all as specified and as directed. | 22.75 | Kg | |
| 23 | 23 | M&L for rendering 5 mm thick in cement mortor (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc.) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed. | 35 | Sqm | |
| 24 | 24 | M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.\n | 268 | Sqm | |
| 25 | 25 | M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. | 23.5 | Cum | |
| 26 | 26 | M&L for 75 mm thick plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filling in proportion of bitumen and sand (1:2) complete all as specified and as directed. | 44 | Sqm | |
| 27 | 27 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. | 4.7 | Cum | |
| 28 | 28 | M&L for 75 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and as directed.\n | 42.3 | Sqm | |
| 29 | 29 | M&L for 40 mm thick, plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floors and finishing the surfaces even and smooth with using extra cement complete all as specified and as directed. | 34.3 | Sqm | |
| 30 | 30 | M&L for machine cut green marble slab flooring 18 to 20mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15 mm thick screed bed or bedding in cement mortor (1:6) and rubbing, polishing complete all as specified and as directed. | 39 | Sqm | |
| 31 | 31 | M&L for machine cut green marble slab for wall lining 18 to 20mm thick (veneering to wall) jointed with grey cement slurry mixed with pigment to match the shade of the slab including 25 mm thick backing coat in cement mortor (1:4) and rubbing, polishing complete all as specified and as directed. | 7 | Sqm | |
| 32 | 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed. | 138 | Sqm | |
| 33 | 33 | M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, including 15 mm thick screed bed or bedding in cement mortor (1:6) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.\n | 16.3 | Sqm | |
| 34 | 34 | M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm in floors etc, including 15 mm thick screed bed or bedding in cement mortor (1:6) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.\n | 140.5 | Sqm | |
| 35 | 35 | M&L for Glazed, ceramic, coloured tiles 7 to 8 mm thick area of each tile not less than 0.06 Sqm on vertical surfaces such as skirting, dados etc, including 10 mm thick backing coat in cement mortor (1:4) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.\n | 71.5 | Sqm | |
| 36 | 36 | M&L for granite stone slab (of any type) 18 to 20 mm thick, machine cut, as in cooking platform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed or bedding in cement mortar (1:6) and cutting, rounding to edge of slab, polishing complete all as specified and as directed. | 11 | Sqm | |
| 37 | 37 | S&F for rolled mild steel work as in truss, purlins, posts etc. using angle, or tee sections, fixed independently, without connecting plates, etc including cutting, welding, drilling holes steel section conforming to Fe-290 (Gde E-165) complete all as specified and as directed. | 435 | Kg | |
| 38 | 38 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. | 24 | Sqm | |
| 39 | 39 | S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed.\nNote : Colour of ridge shall be same colour as that of sheet used for roof. | 18 | Sqm | |
| 40 | 40 | S&F for 6 mm thick asbestos cement sheet, corrugated, or semi corrugated sheets as in roofs, etc. and fixed with 'L' type or 'J'-type or cranked hook bolts complete all as specified and as directed.\n | 18 | Sqm | |
| 41 | 41 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets complete all as specified and as directed. | 105 | Sqm | |
| 42 | 42 | M&L for GI frame work for false ceiling seamless comprising of galvanised iron perimeter channel 0.55mm thick with two unequal flangeds of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermadiate channel 0.90mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre using 4mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40X3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 08mm thick seamless calcium silicate ceiling made out of 1800X1200mm size board of siliceous and calcareous materials reinforced with cellulose fibre fixed to the ceiling section with 25mm long self drilling and tapping screwshaving philips head with under head cutter at 200mm centre to centre, including finishing the joints of face board with specially formulated jointing compound and 48mm wide fibre tape to provide seamless finish complete all as specified and as directed.\nMake of E-Board : Eternit Everest/Lafarge/Armstrong or equivalent as approved by GE | 25 | Sqm | |
| 43 | 43 | S&F for aluminium Anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-boards, HSPC fixed to frame complete all as specified and as directed. | 111.3 | Sqm | |
| 44 | 44 | M&L for second class hard wood mouldings as in cornices, picture rails and the like, sectional area exceeding 13 and not exceeding 25 Sqcm, fixed with nails in ceilings complete all as specified and as directed. | 20 | RM | |
| 45 | 45 | M&L for applying two coat of oil bound distemper over a coat of primer and 2mm thick wall care putty on newly surfaces of seamless calcium silicate ceiling all as specified and as directed. | 130 | Sqm | |
| 46 | 46 | S&F for collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc. as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed. | 7.35 | Sqm | |
| 47 | 47 | M&L for Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290, Gde E-165 complete all as specified and as directed. | 550 | Kg | |
| 48 | 48 | Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. | 3.9 | Cum | |
| 49 | 49 | Demolition of reinforced cement concrete in any position not otherwise specifically provided for complete all as specified and as directed. | 0.8 | Cum | |
| 50 | 50 | M&L for Reinforced Cement Concrete 1:2:4, type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in beam, lintel, cantilevers etc. complete all as specified and as directed.\n | 2.25 | Cum | |
| 51 | 51 | M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and as directed.\n | 3.8 | Cum | |
| 52 | 52 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed. | 5 | Each | |
| 53 | 53 | Taking down chowkats or frames exceeding 1.5 but not exceeding 4.0 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and as directed. | 4 | Each | |
| 54 | 54 | Taking down shutters of any description exc 1.0 Sqm but not exceeding 2.0 Sqm each complete all as specified and as directed. | 1 | Per Leaf | |
| 55 | 55 | M&L for well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. | 0.4 | Cum | |
| 56 | 56 | M&L for 35mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats complete all as specified and as directed. | 7.6 | Sqm | |
| 57 | 57 | M&L for 35 mm thick, glazed/skeleton shutters with second class hard wood,open rebated and prepared to receive glass, gauze, etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc. complete as specified and directed. Sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a) complete all as specified and as directed. | 3.6 | Sqm | |
| 58 | 58 | M&L for 30 mm thick, second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and as directed. | 12.1 | Sqm | |
| 59 | 59 | S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. | 24.1 | RM | |
| 60 | 60 | S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed. | 8.2 | Sqm | |
| 61 | 61 | M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and as directed. | 0.2 | Cum | |
| 62 | 62 | S&F for 125 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed. | 18 | Each | |
| 63 | 63 | S&F for 75 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed. | 39 | Each | |
| 64 | 64 | S&F for 150 mm long, aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed. | 12 | Each | |
| 65 | 65 | S&F for 100 mm long, aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed. | 18 | Each | |
| 66 | 66 | S&F for 150 mm long, Mild Steel, barrel tower bolts, stove enamelled black, with bright bolt complete all as specified and as directed. | 10 | Each | |
| 67 | 67 | S&F for 150 mm size, aluminium handles, cast type, anodised complete all as specified and as directed. | 12 | Each | |
| 68 | 68 | S&F for 100 mm size, aluminium handles, cast type, anodised complete all as specified and as directed. | 22 | Each | |
| 69 | 69 | S&F for mild steel sliding door bolts, 300 mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, etc complete all as specified and as directed. | 6 | Each | |
| 70 | 70 | M&L for anodised aluminium section, medium anodic coating of grade AC 15 for frame of doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed. | 46 | Kg | |
| 71 | 71 | M&L for anodised aluminium door shutters, using aluminium section weighing not less than 0.55 Kg per metre including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium handles two numbers in each shutter, hinges, anodised aluminium snap beading, screws etc complete all as specified and as directed. | 5 | Sqm | |
| 72 | 72 | M&L for anodised aluminium window and ventilator shutters, fixed type, with or without sash bar, using aluminium section weighing not less than 0.55Kg per metre including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium handles two numbers in each shutter, hinges, anodised aluminium snap beading, screws etc complete all as specified and as directed. | 8 | Sqm | |
| 73 | 73 | S&F for 8 mm thick aluminium duco grill size 75x75mm fixed to windows or ventilators with aluminium flat 30x3mm complete all as specified and as directed. | 80 | Kg | |
| 74 | 74 | S&F for 5.0mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.\n | 5 | Sqm | |
| 75 | 75 | S&F for 3mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.\n | 6.5 | Sqm | |
| 76 | 76 | S&F for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.\n | 8 | Sqm | |
| 77 | 77 | M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. | 60 | Sqm | |
| 78 | 78 | M&L for preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. | 60 | Sqm | |
| 79 | 79 | M&L for preparation of new steel surfaces of any description over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed. | 68 | Sqm | |
| 80 | 80 | M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed. | 70 | Sqm | |
| 81 | 81 | M&L for preparing new surfaces of AC sheet/ceiling and applying three coats of white wash complete all as specified and as directed. | 6.3 | Sqm | |
| 82 | 82 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.\n | 180 | Sqm | |
| 83 | 83 | M&L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.\n | 238 | Sqm | |
| 84 | 84 | M&L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and as directed. | 168 | Sqm | |
| 85 | 85 | M&L for preparation of old decorated surfaces of external walls and applying two coat of cement base paint over a coat of alkali resistant primer complete as specified and as directed. | 105 | Sqm | |
| 86 | 86 | M&L for preparation of old decorated plastered surfaces of walls and applying two coat of oil emulsion distemper over a coat of primer as specified and as directed. | 140 | Sqm | |
| 87 | 87 | M&L for preparation of old decorated plastered surfaces of walls and applying two coat of white wash as specified and as directed. | 30 | Sqm | |
| 88 | 88 | Taking up or down 20 mm bore, steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning complete all specified and as directed.\n | 25 | RM | |
| 89 | 89 | Supply, laying, connection and testing, 20 mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified anda as directed. | 160 | RM | |
| 90 | 90 | Taking up or down 15 mm bore, steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as complete all specified and as directed.\n | 15 | RM | |
| 91 | 91 | Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed. | 90 | RM | |
| 92 | 92 | Dismantling of rotational moulded polyethylene water tank of capacity exceeding 500 Litres but not exceeding 1000 Litrs complete all as specified and as directed. | 3 | Each | |
| 93 | 93 | S&F for 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe all as specified in SSR Part I and as directed. | 3 | Each | |
| 94 | 94 | S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe all as specified in SSR Part I and as directed. | 2 | Each | |
| 95 | 95 | S&F for 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed. | 3 | Each | |
| 96 | 96 | S&F for 20 mm bore, gate valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, with iron wheel head, screwed both ends for iron pipe and fixed all complete as specified and as directed. | 1 | Each | |
| 97 | 97 | S&F for 15 mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. | 12 | Each | |
| 98 | 98 | S&F for 15 mm bore, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. | 4 | Each | |
| 99 | 99 | S&F for 15 mm bore, stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. | 2 | Each | |
| 100 | 100 | S&F for 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed. | 2 | Each | |
| 101 | 101 | S&F in repair, 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed. | 1 | Each | |
| 102 | 102 | S&F for 125 mm long, shower rose, brass chromium plated, swival type, complete all as specified and as directed. | 2 | Each | |
| 103 | 103 | S&F for 15 mm dia angle stop cock with flange complete all as specified and as directed.\nMake : Cat No G1807A1 of Parryware/Hindware/CERA/SOMANY/PRAYAG. | 3 | Each | |
| 104 | 104 | S&F for casecade health faucet including hook and hose not less than 1.2 metre long complete all as specified and as directed. \nMake : Cat No. T9937A1 Parryware/Hindware/CERA/SOMANY/PRAYAG. | 1 | Each | |
| 105 | 105 | S&F for brass cromium plated towel ring with fittings complete all as specified and as directed. \nMake : Cat No. T6502A1 Parryware/Hindware/CERA/SOMANY/PRAYAG. | 1 | Each | |
| 106 | 106 | S&F for wall mounted glass corner shelf with fittings complete all as specified and as directed. \nMake : Cat No T6010A1 Parryware/Hindware/CERA/SOMANY/ PRAYAG. | 2 | Each | |
| 107 | 107 | S&F for 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and as directed. | 5 | Each | |
| 108 | 108 | S&F for 15 mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed. | 7 | Each | |
| 109 | 109 | S&F for 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and as directed. | 49 | RM | |
| 110 | 110 | S&F for 75 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with rubber ring joints fixed to wall using MS holder bat for soil pipe/ rain water, etc complete all as specified and as directed. | 5 | RM | |
| 111 | 111 | S&F for 110 mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed. | 4 | Each | |
| 112 | 112 | S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed. | 1 | Each | |
| 113 | 113 | S&F for 75 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed. | 1 | Each | |
| 114 | 114 | S&F for 110 mm bore, PVC (SWR) bends with access end of any radius complete all as specified and as directed. | 6 | Each | |
| 115 | 115 | S&F for 110 mm bore, PVC (SWR) vent cowl complete all as specified and as directed. | 2 | Each | |
| 116 | 116 | S&F in repairs, 32 mm dia, High density poly-ethylene pipes, (HDPE) of pressure rating 6 Kgf/Sqcm laid as in waste pipe of WHB etc complete all as specified and as directed. | 3 | RM | |
| 117 | 117 | S&F for vitreous china urinal, half stall type, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and as directed. | 2 | Each | |
| 118 | 118 | S&F for vitreous china wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and as directed. | 2 | Each | |
| 119 | 119 | S&F in repairs, vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and as directed. | 2 | Each | |
| 120 | 120 | S&F in repairs, vitreous China wash basin, size 550 x 400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and directed.\nMake : Cat No C0450 of Parryware/Hindware/CERA/SOMANY/PRAYAG. | 1 | Each | |
| 121 | 121 | S&F for 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed. | 5 | Each | |
| 122 | 122 | S&F for 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. | 7 | Each | |
| 123 | 123 | M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent\ncement complete all as specified and as directed. | 1 | Each | |
| 124 | 124 | S&F for 32 mm bore brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed. | 1 | Each | |
| 125 | 125 | M&L for salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and as directed. | 34 | RM | |
| 126 | 126 | M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore SGSW/RCC drain pipes complete all as specified and as directed. | 39 | RM | |
| 127 | 127 | Dismantling timber scantlings 40 Sqcm and over in section, in any position complete all as specified and as directed. | 1.1 | Cum | |
| 128 | 128 | M&L for second class hardwood, scantlings, clean sawn, in unframed work complete all as specified and as directed.\n | 1.1 | Cum | |
| 129 | 129 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and as directed. | 105 | Sqm | |
| 130 | 130 | M&L for GI Wire netting 0.90 mm dia, size of mesh 12 mm, lathing to wood or metal studding, joists, etc in walls, etc including all laps, cutting and waste as specified and as directed. | 105 | Sqm | |
| 131 | 131 | M&L for rendering 15 mm thick on one side of lathing in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement as specified and as directed. | 105 | Sqm | |
| 132 | 132 | M&L for rendering 10 mm thick on other side of lathing in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement as specified and as directed. | 105 | Sqm | |
| 133 | 133 | M&L for concealed point wiring with 1.5 Sqmm (nominal area), FR PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete with and including 1.5 Sqmm (nominal area) FR PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in metal flush box of suitable size for mounting switches, sockets, regulators etc including cutting chases and making good by using cement mortar 1:4 complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed. | 13 | Pont | |
| 134 | 134 | S&F for switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed. | 13 | Each | |
| 135 | 135 | S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed. | 3 | Each | |
| 136 | 136 | S&F for switch socket combination, 5 Amp, 5 in 1, 240V, flush type with neon indicator complete all as specified and as directed. | 10 | Each | |
| 137 | 137 | S&F for 18 W surface and wall mounted LED Battern with polycarbonate housing and intigrated electronic driver complete all as specified and as directed.\nMake: Cat No. : LUMILINEBS18WLED865SPCWH of Havells/Philips/Bajaj. | 2 | Each | |
| 138 | 138 | S&F for 10 W LED Recess panel mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation with separate replaceable electronic driver and opal diffuser included cutting-opening of celing any type & fixing arrangement for fitting complete all as specified and as directed by Engineer-in charge.\nMake: Cat No. LHEBHDP7IZ1W010 of Havells/Philips/Bajaj. | 8 | Each | |
| 139 | 139 | S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. | 2 | Each | |
| 140 | 140 | S&F for lamp LED 15 Watt, 220 volts complete all as specified and as directed.\nMake : Havells/Bajaj/Philips. | 2 | Each | |
| 141 | 141 | S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts, 200 Amp suitable for housing MCBs complete all as specified and as directed. | 1 | Each | |
| 142 | 142 | S&F for MCB, SPN, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed.\nMake : Cat No. : TSPNC6-32 of HPL/Havells/Legrand. | 1 | Each | |
| 143 | 143 | S&F MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amp, 'C' Series, 10KA capacity complete all as specified and directed.\nMake : Cat No. TSPC6-32 of HPL/Havells/Legrand. | 6 | Each | |
| 144 | 144 | M&L for Sub main wiring with two run of 1.5 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FR) Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 1.5 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FR) connected to common earth point complete all as specified and as directed.\nNote : (a) One run PVC Casing-caping, two run wiring cables and one run of earth wire will be measured as one length.\n(b) All incoming and outgoing cable shall be connected by using proper lugs & sockets. | 100 | RM | |
| 145 | 145 | M&L for Sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FR) Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FR) connected to common earth point complete all as specified and as directed by Engineer-in-charge.\nNote : (a) One run PVC Casing-caping, two run wiring cables and one run of earth wire will be measured as one length.\n(b) All incoming and outgoing cable shall be connected by using proper lugs & sockets. | 33 | RM | |
| 146 | 146 | S&F for 25 W LED building security new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with hight power LED as lighting source and lens imbedded PC Cover having TOP OPENING seperate driver cmpartment with IP 65 protection and inpact resistance of IK07 complete all as specified and as directed.\nMake : Cat No. : ENDURAPEARLSL25WSASYTOPC of Havells/Philips/Bajaj/Wipro. | 1 | Each | |
| 147 | 147 | M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one/ dismantling complete all as specified and as directed. | 1 | Each | |
| 148 | 148 | Supply, installing, testing and commissioning of ceilling fan, BEE stars rated suitable for single phase AC supply, earthing etc., 230 V, 50Hz, 1200 mm sweep, colour opal white, power input 50 Watt, speed 370 RPM, 3 nos. blades, copper winding, power factor not less 0.9, air delivery minimum 215 CMM, including all fixing accessories and insulation resistance more than 2 mega ohm complete all as specified and as directed.\nMake : Model No. Entrust-50 of Crompton Greaves/Khaitan/Havells. | 347 | Each | |
| 149 | 149 | Supply, installing, testing and commissioning of heavy duty exhaust fan, suitable for single phase AC supply, earthing etc, power input 90 W, 220/240 V, 300 mm sweep size, fan speed 1400 RPM, 4 nos. blades, copper winding, Air delivery minimum 1710 CMM and including all fixing accessories complete all as specified and as directed.\nMake : Model No. EXHD300-4-1 of Crompton Greaves/Khaitan/Havells. | 20 | Each | |
| 150 | 150 | Supply, installing, testing and commissioning of heavy duty exhaust fan, suitable for Single Phase AC supply, earthing etc, power input 150 W, 220/240 V, 380 mm sweep size, fan speed 1400 RPM, 4 nos. blades, copper winding, Air delivery minimum 3250 CMM and including all fixing accessories complete all as specified and as directed.\nMake : Model No. EXHD380-4-1 of Crompton Greaves/Khaitan/Havells. | 8 | Each | |
| 151 | 151 | Supply, installing, testing and commissioning of heavy duty exhaust fan, suitable for Single Phase AC supply, earthing etc, power input 410 W, 220/240 V, 450 mm sweep size, fan speed 1400 RPM, 4 nos. blades, copper winding, Air delivery minimum 6120 CMM and including all fixing accessories complete all as specified and as directed.\nMake : Model No. EXHD450-4-1 of Crompton Greaves/Khaitan/Havells. | 2 | Each | |
| 152 | 152 | Supply, installing, testing and commissioning of heavy duty exhaust fan, suitable for Single Phase AC supply, earthing etc, power input 550 W, 220/240 V, 600 mm sweep size, fan speed 950 RPM, 4 nos. blades, copper winding, Air delivery minimum 9400 CMM and including all fixing accessories complete all as specified and as directed. Make : Model No. EXHD600-6-1 of Crompton Greaves/Khaitan/Havells. | 1 | Each | |
| 153 | 153 | Supply, installing, testing and commissioning of wall mounted fan, suitable for Single Phase AC supply, power input 54 W, 220/240 V, 400 mm sweep size, fan speed 1360 RPM, 3 nos. blades, copper winding, Air delivery minimum 77 CMM and including all fixing accessories complete all as specified and as directed by Engr-in-Charge.\nMake : Model No. SDX BLACK GOLD of Crompton Greaves/Khaitan/Havells. | 17 | Each | |
| 154 | 154 | Supply, installing, testing and commissioning of heavy duty pedestal fan of metal body suitable for Single Phase AC supply, power input 250 W, 220/240 V, 750 mm sweep size, fan speed 1440 RPM, aerodynamically designed blades (3 Nos.) for higher air delivery, copper winding, Air delivery minimum 22200 CMH, adjustable hight (1.75/1.325 mtr), oscillation to 85 degree, heavy base for greater stability complete all as specified and as directed by Engr-in-Charge.\nMake : Model No. ACVORTEX30PF of Crompton Greaves/Khaitan/Havells. | 1 | Each |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy