Rajasthan Rajya Vidhyut Prasaran Nigam Limited has published Purchase Of Various Mccbs And Mcbs And Its Enclosures For Ac And Dc Power Distribution Purchase Of Various Mccbs And Mcbs And Its Enclosures For Ac And Dc Power Distribution At Mahi Hydel Generation Banswara. Submission Date for this Tender is 07-10-2020. Circuit Breakers Tenders in Banswara Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work: Purchase of various MCCB's, MCBs and its enclosures for AC and DC power distribution at Mahi Hydel Genration ,Banswara. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code | Quantity | Units | |
1 | 1 | MCCB for AC Supply, 415VAC/ 50Hz, Themal Release, 3 poles, 2C/O for indications \nIcs=100% Icu. | |||
2 | 1.01 | Rated Current 25 Amp , Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 0.71 | Item2 | 4 | Nos |
3 | 1.02 | Rated Current 25 Amp, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item3 | 4 | Nos |
4 | 1.03 | Rated Current 32 Amp, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item4 | 4 | Nos |
5 | 1.04 | Rated Current 50 Amp,, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 0.71 | Item5 | 8 | Nos |
6 | 1.05 | Rated Current 50 Amp,, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item6 | 8 | Nos |
7 | 1.06 | Rated Current 63 Amp,, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item7 | 1 | Nos |
8 | 1.07 | Rated Current 100 Amp,, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item8 | 12 | Nos |
9 | 1.08 | Rated Current 125 Amp,, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item9 | 4 | Nos |
10 | 1.09 | Rated Current 200 Amp,, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item10 | 3 | Nos |
11 | 1.1 | Rated Current 250 Amp,, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item11 | 3 | Nos |
12 | 1.11 | Rated Current 400 Amp,, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 0.8 | Item12 | 3 | Nos |
13 | 1.12 | Rated Current 400 Amp ( Under Voltage Release) ,, Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item13 | 3 | Nos |
14 | 2 | MCCB for AC Supply, 500VAC/ 50Hz, \nRated Current 100 Amp Breaking Capacity range 20-50KA,Trip Current Setting ratio x=Ir/Ith = 1 | Item14 | 1 | Nos |
15 | 3 | MCCB for DC supply, Thermal Release, 3 poles, 1 C/O or 2C/O for ON, OFF, Fault trip indications, 500 VAC, 50 Hz,Breaking Capacity range for 250 DC 20-50 KA | |||
16 | 3.1 | Rated Current 16 Amp | Item16 | 3 | Nos |
17 | 3.2 | Rated Current 20 Amp, | Item17 | 4 | Nos |
18 | 3.3 | Rated Current 32 Amp | Item18 | 11 | Nos |
19 | 3.4 | Rated Current 50 Amp | Item19 | 1 | Nos |
20 | 3.5 | Rated Current 63 Amp | Item20 | 8 | Nos |
21 | 3.6 | Rated Current 100 Amp | Item21 | 1 | Nos |
22 | 3.7 | Rated Current 125 Amp | Item22 | 1 | Nos |
23 | 3.8 | Rated Current 200 Amp | Item23 | 2 | Nos |
24 | 4 | MCB for AC supply , Single Pole , Breaking Capacity range 10 KA Voltage 240VAC/415VAC 50 Hz . | |||
25 | 4.1 | Rated Current 6 Amp | Item25 | 73 | Nos |
26 | 4.2 | Rated Current 10 Amp | Item26 | 90 | Nos |
27 | 4.3 | Rated Current 16 Amp \n | Item27 | 31 | Nos |
28 | 5 | MCB for AC supply , Double Pole, Breaking Capacity range 10 KA Voltage240VAC/415VAC 50 Hz, Rated Current 6 Amp | |||
29 | 5.1 | Rated Current 6 Amp | Item29 | 30 | Nos |
30 | 5.2 | Rated Current 10 Amp | Item30 | 26 | Nos |
31 | 5.3 | Rated Current 16 Amp | Item31 | 37 | Nos |
32 | 5.4 | Rated Current 32Amp | Item32 | 10 | Nos |
33 | 6 | MCB for AC supply , Triple Pole (TP), Breaking Capacity range 10 KA,Voltage240VAC/415VAC 50 Hz | |||
34 | 6.1 | Rated Current 10 Amp | Item34 | 14 | Nos |
35 | 6.2 | Rated Current 16 Amp | Item35 | 10 | Nos |
36 | 6.3 | Rated Current 32 Amp | Item36 | 40 | Nos |
37 | 6.4 | Rated Current 63 Amp | Item37 | 35 | Nos |
38 | 7 | MCB for AC supply , Four Pole (TPN), Breaking Capacity range 10 KA,Voltage240VAC/415VAC 50 Hz, Rated Current 32 Amp | |||
39 | 7.1 | Rated Current 32 Amp | Item39 | 40 | Nos |
40 | 7.2 | Rated Current 40 Amp | Item40 | 6 | Nos |
41 | 8 | Metallic MCB Distribution Boards (without MCB) 12 way | Item41 | 14 | Nos |
42 | 9 | Metallic MCB Distribution Boards (without MCB) 8way | Item42 | 15 | Nos |
43 | 10 | Metallic MCB Distribution Boards (without MCB) 4 way | Item43 | 20 | Nos |
44 | 11 | Metallic MCB Distribution Boards (without MCB) 2 way | Item44 | 18 | Nos |
45 | 12 | Metal Plug Socket MCB DB’s, 32 Amp, 3 Pins | Item45 | 10 | Nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail