Supply , Installation , Testing And Commissioning Of Indoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System At Gooty Junction Cabin With Alteration At Gooty Junction Station For Gooty Dharmavaram Doubling Work, Gurgaon-Haryana

Rail India Technical And Econimics Services Ltd-RITES has published Supply , Installation , Testing And Commissioning Of Indoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System At Gooty Junction Cabin With Alteration At Gooty Junction Station For Gooty Dharmavaram Doubling Work. Submission Date for this Tender is 12-10-2020. Gear Product Tenders in Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

25528998
Supply , Installation , Testing And Commissioning Of Indoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System At Gooty Junction Cabin With Alteration At Gooty Junction Station For Gooty Dharmavaram Doubling Work
Open Tender
Indian
Haryana
Gurgaon
12-10-2020

Tender Details

Supply , Installation , Testing And Commissioning Of Indoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System At Gooty Junction Cabin With Alteration At Gooty Junction Station For Gooty Dharmavaram Doubling Work

Key Value

Document Fees
INR 7000 /-
EMD
INR 319122.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Supply, Installation, Testing & Commissioning of Indoor gears of Signalling & Telecommunication system including Electronic Interlocking system at Gooty Junction cabin with alteration at Gooty Junction station for Gooty-Dharmavaram doubling work
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, Installation, Testing and Commissioning of Electronic Interlocking (Hot Standby) with dual VDU of 55" with Signalling functions as per RDSO Specification No. RDSO/SPN/192/2019 Ver.2.0 and to suit the signalling plan of Gooty Junction Cabin Yard and to suit the signalling plan of stations.\nScope of supply against this item includes all the indoor equipments necessary for successful functioning of EI system, mainly consisting of but not limited to followings conforming to attached Technical specifications .\n1. Microprocessor equipment.\n2. I/O cards with card cage and motherboard.\n3. Power supply cards.\n4. All types of connectors and couplers as required.\n5. Industrial grade Dual VDU of 55" .\n6. Industrial grade PC & monitor of 40"\n7. maintenance VDU of 40" console with Laser printer at panel building.\n8. All types of relays required for interfacing.\n9. ECRs suitable for LED signal lamps.\n10. DC-DC convertors (input voltage 110 V DC and output voltage as required)\n11. All types of indoor wires as required.\n12. All types of indoor terminals and fuses as required except terminals for main CTR.\n \n\n item2 1 System
2 2 13. Racks for mounting EI equipments and interfacing relays.\n14. Termination rack for indoor cables.\n15. Fixtures, mounting arrangements, Ladders for wire run and other accessories as required.\n16. Softwares used for designing, configuration, maintenance, data logging and fault diagnosis of EI system. \n17. Protective devices like lightning protectors for DC and AC supplies, isolator/convertor for serial communication etc. \n18. Documents and manuals as per RDSO/SPN/192/2019 Ver.2.0 in three sets. \n19. Ring Earthing and EMI shielding of EI room.\n20. Any other item contractor feels neccessary as per their sysyem.\n21.Completion plan of stations.\n22. Class 'A' type surge protection device protection at each SSI room/goomty, mounting arrangements and accessories necessary to make the EI system functional. \n23. Work place for EI is also provided by the contactor\n\n
3 3 24.. Installation, wiring, programming, Bell test,Site acceptance test (SAT), commissioning, Screening arrangementnt with Copper strips ,lightening- protection arrangement,Earthing wiring etc as per Railways practice and All Pre-commissioning tests of EI and other equipments supplied against Gooty Junction Cabin Yard, as per technical specifications of RDSO and OEM . This also includes preparation of design documents and supply of materials for installation, wiring, grouting, cutting of floors, walls etc. refilling of same, replastering, required CC/mesonary works, termination of cables with lugs/connectors, painting/lettering on relay rack/termination rack are to be done by the contractor.
4 4 Note:\n1. Supply of Optic Fibre Cable, 60Cx1mm indoor cable, IPS, KLCR, Main Cable Termination Rack & terminals for Outdoor cables and relay rack for mounting point relays are not included in this item. \n2. Following must be submitted along with offer -\nPlease give full details of quantities & Unit base rate item wise, the total amount of which must be equal to the given in above item. However, scope of supply shall not be limited to BoM given along with offer. 3. All the materials, which are not covered in the BoM for cost break-up submitted by the bidder as above and are neccessary for successful commissioning of system, shall be supplied by the contractor without any extra cost. Variation in Bits and variation in number of routes upto (+) 10% shall have no cost bearing.\n4. For further variation (above 10%) of routes, cost will be recovered on prorata basis for % of routes increased.
5 5 Spares of O&M
6 6 Supply of all spares to the extent of 10% of that supplied against EI item subject to minimum of one, for the cards/modules,connectors /couplers, fuses & relays. used in the EI system at Gooty Junction Cabin Yard. Item-wise details of spares to be supplied with unit rates should be listed out by the tenderer along with offer. item7 1 Lot
7 7 Supply of Laptop based work station for data inputs & configuration, simulation and functional testing, diagnostics, trouble shooting and commissioning of EI system, complete with necessary softwares preloaded. item8 1 No.
8 8 Tool kits and Measuring Instruments for Technicians /Junior Engineers for testing & maintenance and repair at site as specified by Original Equipment Manufacturer of EI. \n\n* Above items includes suitable cabinet for storing tools to ensure longer life. item9 1 Set
9 9 Supply of Hard & soft copy (6 copies as built ) of following indoor drawings for RITES/ Rly approval including one copy on good quality 7.5 micron polyster film: this includes expenses for checking/rechechecking/ obtaing appovals from Railways /RITES .The also includes supply of two sets of drawings for checking, approval and corrections thereon as suggested by RITES/Rly) & threater supply of 2 copies for testing copy & 2 copies as costruction copy.RITES shall make available Schematic SIP.Contractor to Prepare and submit SIP's and other Misc Drgs as per concerened Rly practice and get its approval from railways,if requiered- \n(i) Signalling Interlocking Plan (as per Rly practice)\n(ii) Selection table, \n(iii) Vital & non-vital I/O Bit Chart, \n(iv) EI configuration diagram, Equipment layout plan, Relay disposition chart. \n(v) Front plate diagram of control/indication panel. \n(vi) Application logic \n(vii) Interface circuit with contact analysis. \n(viii) Equivalent circuit of application logic. \n(ix) Prepration & supply of SWRD (station Working Rule Diagram). \n(x) Prepration & supply of station working Rule. 1 Job
10 10 Supply, Installation, Testing and Commissioning of Gooty Junction EI alteration work including Design of EI (Ansaldo Make), FAT, SAT, As made documents including all consumables required for installation and commissioning of Gooty Junction. item11 1 Job
11 11 Simulation Panel including all arrangements of man and materials for Gooty Junction till final Testing item12 1 Job
12 12 Supply & installation of Data logger with interfacing capability with SSI's to moniter Analog & digital inputs(Minimum 12 analog & 512 digital inputs) & enable for networking for a central place as per speci.no. IRS:S-99/2006 with latest amendments. Required type of modem and SSI protocol converter is also to be supplied. item13 1 No
13 13 MISCELLANEOUS
14 14 Relay 'Q' series neutral line, AC Immune, plug-in type, Style `QNA1'. DC Neutral line, 24V, 8F/8B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be ABDGH. item15 1 Nos.
15 15 Relay 'Q' series neutral line, AC Immune, plug-in type, Style `QNA1'. DC Neutral line, 24V, 12F/4B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be ABDFH. item16 1 Nos.
16 16 Relay, point contactor unit along with base plate, Non-AC Immune, plug-In type and capable of controlling Electric point machine operating on 110V DC conforming to IRS:S 46, IRS:S 34 & IRS:S 23 with latest amendment (as applicable) and firm's specification. \nThe unit shall consist of N/R relay (Double wound DC neutral line relay), XR relay (DC Neutral relay). W(N)R/W(R)R - mechanically interlocked relay & WCR (Heavy duty contactor relay with 16 Ampere breaking capacity). All the above relays shall be mounted on pre-wired base plate. item17 1 Nos.
17 17 Supply, Installation, Testing, Commissioning and Integration of the complete System of Microprocessor Based Networkble Analogue Addressable up to 64 nodes 1 Loop Fire Alaram control Panel With Minimum 320 Character LCD Display the panel should be equipped with sufficient nos. of loop. (As per RDSO Specification No. RDSO SPN217/2016 ver 1.0 or latest). Supply of 06 multi detector, 01 Hooter & Strobe, 01 Analogue Addressable Manual Call Point With infegal short circult isolator, analogue addressable protocol having status LED for alarming & standby mode. Electronically addressed, 01 FRLS armoured cables & power with all accessories for connection of all Fire alarm devices. item18 1 NOS
18 18 Training for O&M Staff
19 19 Training of Technician/Jr. Engineers in installation, Testing, commissioning & trouble shooting of Electronic interlocking supplied against item no. 1 of this schedule including provision of hard copies of course modules for each trainee. item20 1 Man month
20 20 Training of Sr. Engineers/Managers in installation, Testing, commissioning, trouble shooting and Repairs supplied against item no. - 1 of this schedule including provision of hard copies of course modules for each trainee. item21 1 Man month