Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #25526605

Comprehensive Maintenance Of Modernized Water Supply System ( Scada ) Under Ge Dronachal

Issued by Statutory Bodies & Commissions/Committees · GE Dronachal, Madhya Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Oct 2020
0 days left
EMD
52400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GE Dronachal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Comprehensive Maintenance Of Modernized Water Supply System ( Scada ) Under Ge Dronachal , schedule a part-i ( scada works ) , operation and maintenance of scada based water supply system/management around the clock inclding sunday and holiday in three shift per day of 08 hours each ( 1st shift from 0600hrs to 1200hrs , 2nd shift from 1400hrs to 2200hrs and 3rd shift 2200hrs to 0600hrs ) by deplying experience and qualified skilled one pump operator in each shift for operation of scada as installed at dronachal base . the contractor will be responsible for repairing maintenance and servicing of all plc panels and all connected circuit/accessories required for motorised water supply system as described below :- ( a ) one trained technician iti qualified having three years experience in relevant field at scada room for attending monitoring the breakdown and preventative maintenance for plc panels and all connected circuits/ accessories in general shift ( upto 330 days ) and one company trained technician once in one month ( oem of plc panel ) and moterised valve for successful working system under ge dronachal . ( b ) servicing and maintenace /repair and replacement of defective components /spare parts with new one of the plc based control panels including all accessories modem , antenna etc . installed at various places , oht and master control station , mimic panel . , ( c ) repair/maintenance by disconnecting cleaning greasing for wear and tear complete servicing , refixing , lathing , installing and commissioning as directed by engr-in charge of all motorised and solenoid valve transmiter , ultrasonic and magnatic level sensor . ( d ) any changes to the programmable logic control ( plc ) in ladder logic of programme changes in operation timing ( limited to the scope of items covered under the contract ) . ( e ) any changes to scada software eg . change in report format , changes in operational screen , operation of soft keys etc . ( limited to the scope of items covered under the contract ) . ( f ) attending breakdown maintenance within three hours of reporting time and replacement of new one as reqd at site complete as specified and directed by engr-in-charge . ( g ) one helper to assist the operator shall be deployed by department/govt . for three shift around the clock including sunday/holiday . ( h ) the work shall be carried out by authorised representative of plc based company proof for the same shall be produced by contractor before commencement of work . , ( j ) the rate quoted by contractor for outsourcing shall not be less than minimum wage rate as noticed by govt . of india/state govt . /local body , whichever is higher . in case the rate quoted by the bidder are less than the prevelling minimum wages rate , the bid will be treated as non-bonafied/invalid and such bid/will not be considered for acceptance . in such case the lowest bidder shall be determined from amongst the valid/bonafied bids only . ( k ) the contractor shall quote the rates inclusive for cleaning of all installation/equipment/plants & mechinery for scada and to be kept in presentable condition at all time . he will be responsible for cutting of vegetation growth etc . by 6mtr radius from permisses of scada installation . ( l ) the contractor shall quote the rate inclusive of all the charges pertains to communication one number bsnl broadband connection with static ip at pump house and gprs enable data card use in all plc panel related to the scope of work . , rates required to be quoted for executing the work as described in srl no 1 . 10 , 1 . 20 & 1 . 30 here-in-before . , skilled workers wage per person as per existing rules , employees provident fund as mentioned in the tender documents , employees state insurance contribution as mentioned in the tender documents , contribution of bonus as mentioned in the tender documents , if applicable . , over head & profit on srl no 1 . 50 to 1 . 80 here-in-before . , gst as mentioned in the tender documents as per existng rules . , schedule a part-ii ( materials & labours ) , comprehensive maintenance for scada server system consisting of pc , printer , screen etc . as required at site including necessary updation suitable antivirus internet charges to upkeep the service for the entire period . , supply & fix single phase preventor model 1 : vsp d2 complete all as specified and directed . ( make : minilec or equivalent ) , supply & fix relay card single c/o 24 v dc complete all as specified and directed . ( make : leon/idec or equivalent ) , supply & fix relay card with base 4 c/o 240v ac complete all as specified and directed . ( make : leon/idec or equivalent ) , supply & fix led indicator colour/red /yellow/green/blue . ( make : esbee/teknic/tele meachnique or equivalent ) , supply & fix plc ( programmable logic controller ) complete all as specified and directed . ( make : mitushibishi , abb , siemens , pheonix contract , schneider ) , supply & fix i/o module for programmable logic controller . ( make : mitushibishi , pheonix contract , schneider or equivalent ) , supply & fix hmi ( homen machine interface ) for programmable logic controller . ( make : mitushibishi , abb , siemens , pheonix contract ) , supply & fix push button with led indicator - 240 v a . c . colour red /green complete all as specified and directed . ( make : esbee/siemens/teknic/tele meachnique or equivalent ) , supply & fix buzzer - 240 v a . ccomplete all as specified and directed . ( make : c&s , mimic or equivalent ) , supply & fix in repairs of flow switch alongwith all necessary parts as required at site . ( make : indfoss/ danfoss/switzer/rapid control ) , supply & fix of pressure switch ( make : indfoss/danfoss ) , supply & fix electric motor suitable for actuator of the following size complete all as specified and directed ( make : ritetork/universal switch gear co . or equivalent ) . , ( a ) 50/80 mm dia , ( b ) 100 mm dia , ( c ) 150 mm dia , ( d ) 200 mm dia , ( e ) 250 mm dia , supply & fix in repair for single phase moterised acuted butterfly valve for the following sizes ( make : audco/ virgo/l&t/hasel/hofner ) :- , ( a ) 50 mm dia , ( b ) 80 mm dia , ( c ) 100 mm dia , ( d ) 150 mm dia , ( e ) 200 mm dia , ( f ) 250 mm dia , supply & fix power capacitor for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve complete all as specified and directed . ( make : universal switchgear co . or equivalent ) , supply & fix resistor for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve complete all as specified and directed . ( make : universal switchgear co . or equivalent ) , supply & fix limit switch for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve complete all as specified and directed . ( make : universal switchgear co . or equivalent ) , supply & fix smps input 230 v/ac , output 24v dc complete all as specified and directed . ( make : nhp/ telemehanique or equivalent ) , supply & fix ultrasonic level sensor range 0-5m make: banner ( make : banner or equivalent ) , supply & fix gprs modem complete all as specified and required at site . , supply & fix 9db antenna gprs modem complete all as specified and directed . , supply only ups battary for 12v 150 amp complete all as specified and directed . ( make : exide or eqivalent ) , supply & fix selector switch 2/3 pole suitable for auto/manual main power supply complete all as specified and directed . ( make : esbee/teknic/tele meachnique or equivalent ) , supply & fix 2kva inverter with sealed acid maintenance free battries for powering the panel upto the period minimum 06 hours . ( make : numeric/apc/tata/luminius ) , supply & fix mcb 3p 6a complete all as specified a

BOQ

Name of Work: Comprehensive Maintenance of modernised water supply system (SCADA) under GE Dronachal.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11SCHEDULE 'A' PART-I (SCADA WORKS)
21.1Operation and maintenance of SCADA based water supply system/management around the clock inclding Sunday and Holiday in three shift per day of 08 hours each (1st shift from 0600hrs to 1200hrs, 2nd shift from 1400hrs to 2200hrs and 3rd shift 2200hrs to 0600hrs) by deplying experience and qualified skilled one pump operator in each shift for operation of SCADA as installed at Dronachal Base. The contractor will be responsible for repairing maintenance and servicing of all PLC panels and all connected circuit/accessories required for motorised water supply system as described below :-\n(a) One trained technician ITI qualified having three years experience in relevant field at SCADA room for attending monitoring the breakdown and preventative maintenance for PLC panels and all connected circuits/ accessories in general shift (upto 330 days) and one company trained technician once in one month (OEM of PLC Panel) and moterised valve for successful working system under GE Dronachal.\n(b) Servicing and maintenace /repair and replacement of defective components /spare parts with new one of the PLC based control panels including all accessories modem, antenna etc. installed at various places, OHT and Master control station, Mimic panel. \n
31.2(c) Repair/maintenance by disconnecting cleaning greasing for wear and tear complete servicing, refixing, lathing, installing and commissioning as directed by Engr-in Charge of all motorised and solenoid valve transmiter, Ultrasonic and magnatic level sensor.\n(d) Any changes to the programmable logic control (PLC) in ladder logic of programme changes in operation timing (limited to the scope of items covered under the contract).\n(e) Any changes to SCADA software eg. change in report format, changes in operational screen, operation of soft keys etc. (limited to the scope of items covered under the contract).\n(f) Attending breakdown maintenance within three hours of reporting time and replacement of new one as reqd at site complete as specified and directed by Engr-in-Charge.\n(g) One helper to assist the operator shall be deployed by Department/Govt. for three shift around the clock including Sunday/Holiday.\n(h) The work shall be carried out by authorised representative of PLC based company proof for the same shall be produced by contractor before commencement of work.
41.3(j) The rate quoted by contractor for outsourcing shall not be less than minimum wage rate as noticed by Govt. of India/State Govt./local body, whichever is higher. In case the rate quoted by the bidder are less than the prevelling minimum wages rate, the bid will be treated as non-bonafied/invalid and such bid/will not be considered for acceptance. In such case the lowest bidder shall be determined from amongst the valid/bonafied bids only.\n(k) The contractor shall quote the rates inclusive for cleaning of all installation/equipment/plants & mechinery for SCADA and to be kept in presentable condition at all time. He will be responsible for cutting of vegetation growth etc. by 6mtr radius from permisses of SCADA installation.\n(l) The contractor shall quote the rate inclusive of all the charges pertains to communication one number BSNL Broadband connection with static IP at pump house and GPRS enable data card use in all PLC panel related to the scope of work.
51.4Rates required to be quoted for executing the work as described in Srl No 1.10, 1.20 & 1.30 here-in-before.
61.5Skilled worker's wage per person as per existing rules \n990Per Shift
71.6Employees Provident Fund as mentioned in the tender documents990Per Shift
81.7Employees State Insurance Contribution as mentioned in the tender documents\n990Per Shift
91.8Contribution of Bonus as mentioned in the tender documents, if applicable.\n990Per Shift
101.9Over head & Profit on srl No 1.50 to 1.80 here-in-before.990Per Shift
112GST as mentioned in the tender documents as per existng rules.990Per Shift
123SCHEDULE 'A' PART-II (MATERIALS & LABOURS)
133.1Comprehensive maintenance for SCADA server system consisting of PC, printer, screen etc. as required at site including necessary updation suitable antivirus internet charges to upkeep the service for the entire period.1Job
144Supply & Fix single phase Preventor Model 1 : VSP D2 complete all as specified and directed. (Make : MINILEC or equivalent)\n6Each
155Supply & Fix Relay card single C/O 24 V DC complete all as specified and directed. (Make : LEON/IDEC or Equivalent)60Each
166Supply & Fix Relay card with base 4 C/O 240V AC complete all as specified and directed.(Make : LEON/IDEC or Equivalent)60Each
177Supply & Fix LED Indicator Colour/Red /yellow/Green/Blue. (Make : ESBEE/TEKNIC/TELE MEACHNIQUE or equivalent)40Each
188Supply & Fix PLC (Programmable Logic Controller) complete all as specified and directed. (Make : MITUSHIBISHI, ABB, SIEMENS, PHEONIX CONTRACT, SCHNEIDER)\n2Each
199Supply & Fix I/O module for Programmable Logic Controller. (Make : MITUSHIBISHI, PHEONIX CONTRACT, SCHNEIDER or equivalent)\n4Each
2010Supply & Fix HMI (Homen Machine Interface) for Programmable Logic Controller. (Make : MITUSHIBISHI, ABB, SIEMENS, PHEONIX CONTRACT)\n2Each
2111Supply & Fix push button with LED Indicator - 240 V A.C. Colour Red /Green complete all as specified and directed. (Make : ESBEE/SIEMENS/TEKNIC/TELE MEACHNIQUE or equivalent)8Each
2212Supply & Fix Buzzer - 240 V A.Ccomplete all as specified and directed. (MAKE : C&S, MIMIC or equivalent)4Each
2313Supply & Fix in repairs of Flow switch alongwith all necessary parts as required at site. (Make : INDFOSS/ DANFOSS/SWITZER/RAPID CONTROL)1Each
2414Supply & Fix of Pressure switch\n(Make : INDFOSS/DANFOSS)2Each
2515Supply & Fix Electric motor suitable for actuator of the following size complete all as specified and directed (Make : RITETORK/UNIVERSAL SWITCH GEAR CO. or equivalent). \n
2615.1(a) 50/80 mm dia3Each
2715.2(b) 100 mm dia3Each
2815.3(c) 150 mm dia8Each
2915.4(d) 200 mm dia4Each
3015.5(e) 250 mm dia3Each
3116Supply & Fix in repair for single phase moterised acuted butterfly valve for the following sizes (Make : AUDCO/ VIRGO/L&T/HASEL/HOFNER) :- \n
3216.1(a) 50 mm dia2Each
3316.2(b) 80 mm dia3Each
3416.3(c) 100 mm dia2Each
3516.4(d) 150 mm dia8Each
3616.5(e) 200 mm dia3Each
3716.6(f) 250 mm dia3Each
3817Supply & Fix Power Capacitor for Actuator suitable for 50/80/100/150 mm dia Motorized Butterfly Valve complete all as specified and directed. (Make : UNIVERSAL SWITCHGEAR CO. or equivalent)5Each
3918Supply & Fix Resistor for Actuator suitable for 50/80/100/150 mm dia motorized Butterfly Valve complete all as specified and directed. (Make : UNIVERSAL SWITCHGEAR CO. or equivalent)5Each
4019Supply & Fix Limit switch for Actuator suitable for 50/80/100/150 mm dia motorized Butterfly Valve complete all as specified and directed.(Make : UNIVERSAL SWITCHGEAR CO. or equivalent)10Each
4120Supply & Fix SMPS input 230 V/AC, Output 24V DC complete all as specified and directed. (Make : NHP/ TELEMEHANIQUE or equivalent)1Each
4221Supply & Fix Ultrasonic Level Sensor range 0-5M Make: Banner (Make : BANNER or equivalent)1Each
4322Supply & Fix GPRS Modem complete all as specified and required at site.1Each
4423Supply & Fix 9DB Antenna GPRS Modem complete all as specified and directed.2Each
4524Supply only UPS Battary for 12V 150 Amp complete all as specified and directed. (Make : EXIDE or eqivalent)1Each
4625Supply & Fix Selector switch 2/3 pole suitable for auto/manual main power supply complete all as specified and directed. (Make : ESBEE/TEKNIC/TELE MEACHNIQUE or equivalent)1Each
4726Supply & Fix 2KVA inverter with sealed acid maintenance free battries for powering the panel upto the period minimum 06 hours. (Make : NUMERIC/APC/TATA/LUMINIUS)3Each
4827Supply & Fix MCB 3P 6A complete all as specified and directed.2Each
4928Supply & Fix coil for solenoid valve 10mm dia 230 Volt AC brass or stainless steel body with suitable pressure of coil power 6 Watt.3Each
5029Ditto as per item No 28 above but for 25 mm dia.3Each
5130Supply & Fix motorized ball valve 25 mm complete all as specified and directed. (Make : UNIVERSAL SWITCHGEAR or equivalent)3Each

AI Tender Summary

OUR REF NO 25526605
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 16-10-2020
Authority
Authority Name Military Engineer Services
Work Description Comprehensive Maintenance Of Modernized Water Supply System ( Scada ) Under Ge Dronachal , schedule a part-i ( scada works ) , operation and maintenance of scada based water supply system/management around the clock inclding sunday and holiday in three shift per day of 08 hours each ( 1st shift from 0600hrs to 1200hrs , 2nd shift from 1400hrs to 2200hrs and 3rd shift 2200hrs to 0600hrs ) by deplying experience and qualified skilled one pump operator in each shift for operation of scada as installed at dronachal base . the contractor will be responsible for repairing maintenance and servicing of all plc panels and all connected circuit/accessories required for motorised water supply system as described below :- ( a ) one trained technician iti qualified having three years experience in relevant field at scada room for attending monitoring the breakdown and preventative maintenance for plc panels and all connected circuits/ accessories in general shift ( upto 330 days ) and one company trained technician once in one month ( oem of plc panel ) and moterised valve for successful working system under ge dronachal . ( b ) servicing and maintenace /repair and replacement of defective components /spare parts with new one of the plc based control panels including all accessories modem , antenna etc . installed at various places , oht and master control station , mimic panel . , ( c ) repair/maintenance by disconnecting cleaning greasing for wear and tear complete servicing , refixing , lathing , installing and commissioning as directed by engr-in charge of all motorised and solenoid valve transmiter , ultrasonic and magnatic level sensor . ( d ) any changes to the programmable logic control ( plc ) in ladder logic of programme changes in operation timing ( limited to the scope of items covered under the contract ) . ( e ) any changes to scada software eg . change in report format , changes in operational screen , operation of soft keys etc . ( limited to the scope of items covered under the contract ) . ( f ) attending breakdown maintenance within three hours of reporting time and replacement of new one as reqd at site complete as specified and directed by engr-in-charge . ( g ) one helper to assist the operator shall be deployed by department/govt . for three shift around the clock including sunday/holiday . ( h ) the work shall be carried out by authorised representative of plc based company proof for the same shall be produced by contractor before commencement of work . , ( j ) the rate quoted by contractor for outsourcing shall not be less than minimum wage rate as noticed by govt . of india/state govt . /local body , whichever is higher . in case the rate quoted by the bidder are less than the prevelling minimum wages rate , the bid will be treated as non-bonafied/invalid and such bid/will not be considered for acceptance . in such case the lowest bidder shall be determined from amongst the valid/bonafied bids only . ( k ) the contractor shall quote the rates inclusive for cleaning of all installation/equipment/plants & mechinery for scada and to be kept in presentable condition at all time . he will be responsible for cutting of vegetation growth etc . by 6mtr radius from permisses of scada installation . ( l ) the contractor shall quote the rate inclusive of all the charges pertains to communication one number bsnl broadband connection with static ip at pump house and gprs enable data card use in all plc panel related to the scope of work . , rates required to be quoted for executing the work as described in srl no 1 . 10 , 1 . 20 & 1 . 30 here-in-before . , skilled workers wage per person as per existing rules , employees provident fund as mentioned in the tender documents , employees state insurance contribution as mentioned in the tender documents , contribution of bonus as mentioned in the tender documents , if applicable . , over head & profit on srl no 1 . 50 to 1 . 80 here-in-before . , gst as mentioned in the tender documents as per existng rules . , schedule a part-ii ( materials & labours ) , comprehensive maintenance for scada server system consisting of pc , printer , screen etc . as required at site including necessary updation suitable antivirus internet charges to upkeep the service for the entire period . , supply & fix single phase preventor model 1 : vsp d2 complete all as specified and directed . ( make : minilec or equivalent ) , supply & fix relay card single c/o 24 v dc complete all as specified and directed . ( make : leon/idec or equivalent ) , supply & fix relay card with base 4 c/o 240v ac complete all as specified and directed . ( make : leon/idec or equivalent ) , supply & fix led indicator colour/red /yellow/green/blue . ( make : esbee/teknic/tele meachnique or equivalent ) , supply & fix plc ( programmable logic controller ) complete all as specified and directed . ( make : mitushibishi , abb , siemens , pheonix contract , schneider ) , supply & fix i/o module for programmable logic controller . ( make : mitushibishi , pheonix contract , schneider or equivalent ) , supply & fix hmi ( homen machine interface ) for programmable logic controller . ( make : mitushibishi , abb , siemens , pheonix contract ) , supply & fix push button with led indicator - 240 v a . c . colour red /green complete all as specified and directed . ( make : esbee/siemens/teknic/tele meachnique or equivalent ) , supply & fix buzzer - 240 v a . ccomplete all as specified and directed . ( make : c&s , mimic or equivalent ) , supply & fix in repairs of flow switch alongwith all necessary parts as required at site . ( make : indfoss/ danfoss/switzer/rapid control ) , supply & fix of pressure switch ( make : indfoss/danfoss ) , supply & fix electric motor suitable for actuator of the following size complete all as specified and directed ( make : ritetork/universal switch gear co . or equivalent ) . , ( a ) 50/80 mm dia , ( b ) 100 mm dia , ( c ) 150 mm dia , ( d ) 200 mm dia , ( e ) 250 mm dia , supply & fix in repair for single phase moterised acuted butterfly valve for the following sizes ( make : audco/ virgo/l&t/hasel/hofner ) :- , ( a ) 50 mm dia , ( b ) 80 mm dia , ( c ) 100 mm dia , ( d ) 150 mm dia , ( e ) 200 mm dia , ( f ) 250 mm dia , supply & fix power capacitor for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve complete all as specified and directed . ( make : universal switchgear co . or equivalent ) , supply & fix resistor for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve complete all as specified and directed . ( make : universal switchgear co . or equivalent ) , supply & fix limit switch for actuator suitable for 50/80/100/150 mm dia motorized butterfly valve complete all as specified and directed . ( make : universal switchgear co . or equivalent ) , supply & fix smps input 230 v/ac , output 24v dc complete all as specified and directed . ( make : nhp/ telemehanique or equivalent ) , supply & fix ultrasonic level sensor range 0-5m make: banner ( make : banner or equivalent ) , supply & fix gprs modem complete all as specified and required at site . , supply & fix 9db antenna gprs modem complete all as specified and directed . , supply only ups battary for 12v 150 amp complete all as specified and directed . ( make : exide or eqivalent ) , supply & fix selector switch 2/3 pole suitable for auto/manual main power supply complete all as specified and directed . ( make : esbee/teknic/tele meachnique or equivalent ) , supply & fix 2kva inverter with sealed acid maintenance free battries for powering the panel upto the period minimum 06 hours . ( make : numeric/apc/tata/luminius ) , supply & fix mcb 3p 6a complete all as specified a
Basic Detail
Tender No 8573/E8
Bidding Type Tender
Location
City GE Dronachal
State Madhya Pradesh
Key Dates
Publish Date 22 Sep 2020
Submission Date 16 Oct 2020
Open Date 22 Oct 2020
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 52400
Exemption Not Available
Document List
generalpages8573.pdf
Tendernotice_1.pdf
BOQ_423904.xls
2762E025-7AF5-4440-91F6-93850A8779B3.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 16, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 22, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

generalpages8573.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_423904.xls

html

2762E025-7AF5-4440-91F6-93850A8779B3.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders