Providing And Fixing No . 1 High Mast And Led At Wagholi Taluka Kallamb Dist . Osmanabad Location 0Sathenagar Providing And Fixing No . 1 High Mast And Led At Wagholi Taluka Kallamb Dist . Osmanabad Location Sathenagar
Tender Overview
Project Description
Providing And Fixing No . 1 High Mast And Led At Wagholi Taluka Kallamb Dist . Osmanabad Location 0Sathenagar Providing And Fixing No . 1 High Mast And Led At Wagholi Taluka Kallamb Dist . Osmanabad Location Sathenagar , Item No . 1: Supplying And Erecting Pvc Insulated Pvc Round Sheathed 1 . 5 Sq . Mm . ( 30 No . X 0 . 25 Mm . Dia . ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Upto 1 . 1 Kv ( Csr No . 1-3-27 ) , Item No . 2: Supplying And Erecting Led Flood Light Fitting Of 120W , Including Lamp , With Pf> 0 . 95 , Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification No . Fg-Odf/ Fls-2 ( Csr No . 2-5-16 ) , Item No . 3: Supplying And Erecting Two Pole Power Contactor 230 V , 12A For Time Switch Complete Erected On Provided Wooden Block/ Box , With Necessary Materials . ( Csr No . 4-4-2 ) , Item No . 4: Supplying And Erecting Programmable Digital Almanac Timer Microcontroller Based With Real Time Clock To Operate On Derived Switching On & Switching Off Street Light As Per Daily Sunset And Sunrise Respectively Automatically Having 4 Digit Led Continuous Time Display , Relay Output 230 V /10 A With 10 Hrs Battery Backup And Manual Over Drive Facility Capable Todrive Different Capacity Contractors Timer Erected In Provided M . S . Box In An Approved Manner . ( Csr No . 4-4-6 ) , Item No . 5: Supplying , Erecting & Marking Spmcb 6A To 32A , B-Series ( For Lighting ) In Provided Distribution Board As Per Specification No . Sw- Swr/ Mcb ( Csr No . 5-3-3 ) , Item No . 6:- Supplying , Erecting And Marking Dpmcb 6A To 32A , B-Series ( For Lighting ) In Provided Distribution Board As Per Specification No . Sw-Swr/Mcb ( Csr No . 5-3-7 ) , Item No . 7: Supplying , Erecting & Terminating Xlpe Armoured Cable 2 Core 6 Sq . Mm . Aluminium Conductor With Continuous 5 . 48 Sq . Mm . ( 12 Swg ) G . I . Earth Wire Complete Erected With Glands And Lugs , On Wall / Trusses/ Pole Or Laid In Provided Trench / Pipe As Per Specification No . Cb-Lt/Al ( Csr No . 7-1-5 ) , Item No . 8: Supplying And Erecting G . I . Pipe A Class 40Mm . Dia . Erected For Enclosing Xlpe Armoured Cable On Wall/ Pole As Per Specification No . Cb-Ce ( Csr No . 7-6-2 ) , Item No . 9: Supplying And Erecting 9M . ( Clear Height ) Fixed Type High Mast ( Top-100 Mm . , Bottom-200 Mm . ) With Hexagonal / Round Bracket And Foundation Bolts Suitable For Max . 4 Nos . Flood Light Fixtures On Provided Foundation As Per Specification No . Oh-Pl/ Opl ( Excluding Luminaries ) ( Csr No . 8-3-8 ) , Item No . 10: Supplying And Erecting Mains With Isi Mark Wp 2 X 2 . 5 Sq . Mm . 1100 V Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G . I . Bearer Wire No . 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G . I . Binding Wire ( Csr No . 1-4-1 ) , Item No . 11: Supplying And Erecting Street Light Bracket For Erection Of Side Entry Fitting On Pole With 40Mm . Dia . B Grade G . I . Pipe Of Required Length Complete As Per Specification No . Fg-Bkt/Slb ( Csr No . 2-9-9 ) , Item No . 12:- Supplying And Erecting Led Street Light Light Fitting Suitable For Above 75W- 90W Lamp , Including Lamp , With Pf> 0 . 95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification No . Fg-Odf/Fls2 ( Csr No . 2-5-7 ) , Item No . 13: Supplying , Erecting And Marking Enclosure Single Pole And Neutral Distribution Board ( Spndb ) One Way For Spmcb 1 No . On Iron / Gi Frame As Per Specification No . Sw-Swr / Mcbdb ( Csr No . 5-4-13 ) , Item No . 14:- Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0 . 6 Cm . Complete With All Materials , Testing And Recording The Results As Per Specification No . Ea-Ep ( Csr No . 9-1-1 ) , Item No . 15: Making Trench Of Suitable Width And Depth In Hard Murum/ Tar Road For Laying Provided Lt Cable Up To And Including 16 Sq . Mm . Complete As Per Specification No . Cw-Exn-Ctr ( Csr No . 16-1-2 ) , Item No . 16: Making M-20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/ Sq . M . At 1 . 5 M . Depth Including Supply Of Steel , Concrete , Excavation And Fixing Provided Nut Bolts With The Help Of Template , Duly Plastered As Per Design Complete ( For 9 M . And 10M High Octagonal/ Conical Gi Pole ( Csr No . 16-3-10 ) , Item No . 17: Fixing In Position Informatory Board In Ground With C . C . 1:4:8 Block Of 60Cm X 60Cm X 75Cm . Size Including All Leads Comp . Pwd Civil Ssr 2019-20 Item No . 6 . 20 , Item No . 18: Third Party Inspection / Testing Charges
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Sep-2020 | Corrigendum | Date | 30-Sep-2020 |
BOQ
| Name of Work:- Providing and fixing No.1 High Mast & LED at Wagholi Taluka Kallamb Dist. Osmanabad (Location: 0262 Sathenagar ) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Item No.1: Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm. (30 no. x 0.25 mm. dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade upto 1.1 kV (CSR No.1-3-27 ) | BI01010001010000000000000515BI0100001110 | 39 | Mtr. |
| 2 | 2 | Item No.2: Supplying and erecting LED flood light fitting of 120W, including lamp, with PF> 0.95, class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No. FG-ODF/ FLS-2 (CSR No. 2-5-16 ) | BI01010001010000000000000515BI0100001111 | 4 | No. |
| 3 | 3 | Item No.3: Supplying and erecting two pole power contactor 230 V, 12A for time switch complete erected on provided wooden block/ box, with necessary materials. (CSR No.4-4-2) | BI01010001010000000000000515BI0100001112 | 1 | No. |
| 4 | 4 | Item No.4: Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching \"ON\" & switching \"OFF\" street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230 V /10 A with 10 hrs battery backup and manual over drive facility capable todrive different capacity contractors timer erected in provided M.S. Box in an approved manner. (CSR No.4-4-6 ) | BI01010001010000000000000515BI0100001113 | 1 | No. |
| 5 | 5 | Item No.5: Supplying, erecting & marking SPMCB 6A to 32A, B-series (for lighting) in provided distribution board as per specification No. SW- SWR/ MCB ( CSR No. 5-3-3 ) | BI01010001010000000000000515BI0100001114 | 12 | No. |
| 6 | 6 | Item No.6:- Supplying, erecting and marking DPMCB 6A to 32A, B-series ( for lighting) in provided distribution board as per specification No. SW-SWR/MCB (CSR No. 5-3-7 ) | BI01010001010000000000000515BI0100001115 | 1 | No. |
| 7 | 7 | Item No.7: Supplying, erecting & terminating XLPE armoured cable 2 core 6 sq.mm. aluminium conductor with continuous 5.48 sq.mm. ( 12 SWG) G.I. earth wire complete erected with glands and lugs, on wall / trusses/ pole or laid in provided trench / pipe as per specification No. CB-LT/AL (CSR No. 7-1-5 ) | BI01010001010000000000000515BI0100001116 | 17 | Mtr. |
| 8 | 8 | Item No.8: Supplying and erecting G.I. pipe 'A' class 40mm. Dia. Erected for enclosing XLPE armoured cable on wall/ pole as per specification No. CB-CE (CSR No. 7-6-2 ) | BI01010001010000000000000515BI0100001117 | 3 | Mtr. |
| 9 | 9 | Item No.9: Supplying and erecting 9m. (clear height) fixed type High Mast ( Top-100 mm., Bottom-200 mm.) with hexagonal / round bracket and foundation bolts suitable for max. 4 Nos. flood light fixtures on provided foundation as per specification No. OH-PL/ OPL ( excluding luminaries) (CSR No.8-3-8 ) | BI01010001010000000000000515BI0100001118 | 1 | No. |
| 10 | 10 | Item No.10: Supplying and erecting mains with ISI mark WP 2 x 2.5 sq.mm. 1100 V grade aluminium PVC Insulated and PVC sheathed wires on G.I. bearer wire No.8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire ( CSR No. 1-4-1 ) | BI01010001010000000000000515BI0100001119 | 47 | Mtr. |
| 11 | 11 | Item No.11: Supplying and erecting Street Light bracket for erection of side entry fitting on pole with 40mm. Dia. 'B' grade G.I. pipe of required length complete as per specification No. FG-BKT/SLB (CSR No.2-9-9 ) | BI01010001010000000000000515BI0100001120 | 8 | Mtr. |
| 12 | 12 | Item No.12:- Supplying and erecting LED Street Light light fitting suitable for above 75W- 90W lamp, including lamp, with PF> 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No. FG-ODF/FLS2 (CSR No. 2-5-7 ) | BI01010001010000000000000515BI0100001121 | 8 | No. |
| 13 | 13 | Item No.13: Supplying, erecting and marking enclosure single pole and neutral distribution board (SPNDB) one way for SPMCB 1 No. on iron / GI frame as per specification No. SW-SWR / MCBDB (CSR No. 5-4-13 ) | BI01010001010000000000000515BI0100001122 | 8 | No. |
| 14 | 14 | Item No.14:- Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm. complete with all materials, testing and recording the results as per specification No. EA-EP (CSR No. 9-1-1 ) | BI01010001010000000000000515BI0100001123 | 1 | No. |
| 15 | 15 | Item No.15: Making trench of suitable width and depth in hard murum/ tar road for laying provided LT cable up to and including 16 sq.mm. complete as per specification No. CW-EXN-CTR (CSR No. 16-1-2 ) | BI01010001010000000000000515BI0100001124 | 10 | No. |
| 16 | 16 | Item No.16: Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/ sq.m. at 1.5 m. depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 9 m. and 10m high octagonal/ conical GI pole (CSR No.16-3-10 ) | BI01010001010000000000000515BI0100001125 | 1 | No. |
| 17 | 17 | Item No.17: Fixing in position Informatory Board in ground with C.C. 1:4:8 block of 60cm x 60cm x 75cm. Size including all leads comp. PWD Civil SSR 2019-20 Item No.6.20 | BI01010001010000000000000515BI0100001126 | 1 | No. |
| 18 | 18 | Item No.18: Third Party Inspection / Testing charges | BI01010001010000000000000515BI0100001127 | 1 | No. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender