Military Engineer Services-MES has published Repair/Maint Of Air Handling Units And Connected Works In Tech Area At Af Stn Gwalior. Submission Date for this Tender is 09-10-2020. Air Handling Unit Tenders in GE AF TA GWALIOR Madhya Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR/MAINT OF AIR HANDLING UNITS AND CONNECTED WORKS IN TECH AREA AT AF STN GWALIOR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | S&F ‘V’ belts of following cross section, pitch length & size including disconnection and taking down of ‘V’ belts from motors complete all as specified and directed :-\nMake : Fenner / Hilton. \n | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | Cross section 13 x 08 mm & pitch length 740 mm of size A-28. | BI01010001010000000000000515BI0100001114 | 6 | Each |
3 | 1.02 | Cross section 13 x 08 mm & pitch length 970 mm of size A-37 | BI01010001010000000000000515BI0100001115 | 6 | Each |
4 | 1.03 | Cross section 13 x 08 mm & pitch length 1200 mm of size A-46 | BI01010001010000000000000515BI0100001116 | 6 | Each |
5 | 1.04 | Cross section 13 x 08 mm & pitch length 850 mm of size A-32 . | BI01010001010000000000000515BI0100001117 | 6 | Each |
6 | 1.05 | Cross section 17 x 11 mm & pitch length 2150 mm of size B-83. | BI01010001010000000000000515BI0100001119 | 6 | Each |
7 | 1.06 | Cross section 17 x 11 mm & pitch length 2280 mm of size B-88. | BI01010001010000000000000515BI0100001120 | 6 | Each |
8 | 1.07 | Cross section 17 x 11 mm & pitch length 2380 mm of size B-92. | BI01010001010000000000000515BI0100001121 | 6 | Each |
9 | 1.08 | Cross section 17 x 11 mm & pitch length 2630 mm of size B-102. | BI01010001010000000000000515BI0100001122 | 6 | Each |
10 | 1.09 | Cross section 17 x 11 mm & pitch length 2710 mm of size B-105. | BI01010001010000000000000515BI0100001123 | 6 | Each |
11 | 1.1 | Cross section 17 x 11 mm & pitch length 3450 mm of size B-134. | BI01010001010000000000000515BI0100001124 | 6 | Each |
12 | 1.11 | Cross section 17 x 11 mm & pitch length 2310 mm of size B-90 | 6 | Each | |
13 | 1.12 | Cross section 17 x 11 mm & pitch length 750 mm of size B-28 | 6 | Each | |
14 | 1.13 | Cross section 22 x 14 mm & pitch length 3210 mm of size C-124 | 6 | Each | |
15 | 1.14 | Cross section 22 x 14 mm & pitch length 3000 mm of size C-116 | 6 | Each | |
16 | 1.15 | Cross section 22 x 14 mm & pitch length 2950 mm of size C-114 | 6 | Each | |
17 | 2 | M&L for insulation of pipe with using insulation synthetic PVC insulation sheet 19 mm thick including applying PVC adhesive tape on joints complete all as specified and directed. | 50 | RM | |
18 | 3 | Disconnecting, dismantling and strip opening of the existing Air Handling Unit of any description and of any position upto 10000CFM for overhauling and servicing including dismantling of u/s item like Shaft, Motor, Drum Pulley, Bearing, Humidifier pipe etc, checking thouroughly the serviceability of the parts, dismantling the parts, fixing the servicible parts in position, replacement of the defective/ non functional/unserviceable parts, reassembling, comminsioning, fixing in postion and testing of air handling unit on full load for its smooth and trouble free operation complete all as specified and directed.\nNote :- (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new parts shall be measured and paid for separately under appropriate item of schedule'A'/BOQ as supply only.\n(ii) Remetalling and grinding of the crank shaft wherever applicabel shall be measured and paid for separately under appropriate item of schedule 'A'/BOQ.\n(iii) Rate quoted by contractor shall include the cost of transportation of any parts of the AHU unit to and fro approved workshop for their repair and re-alignment. | 15 | Each Job | |
19 | 4 | ditto all per item No 3 above but, for air handling unit of above 10000 and upto 20000 CFM capacity complete all as specified and directed .-ditto-\nNote:- All as per Item No 3 | 5 | Each Job | |
20 | 5 | ditto all per item No 3 above but, for air handling unit of above 20000 and upto 30000 CFM capacity complete all as specified and directed .-ditto-\nNote:- All as per Item No 3 | 5 | Each Job | |
21 | 6 | Supply only the following spares / parts suitable for Air handling units repaired under respective Sch ‘A’ item No. 3 to 5 for servicing / overhauling of AHU complete all as specified and directed.\n(Note (i) Cost element of removing unserviceable parts, fixing and testing of the new items/ parts is deemed to be included in the respective rates quoted by the contractor under respective Sch ‘A’ Sl No. 3 to 5 for servicing / overhauling of AHU.\n(ii) Contractor shall have no claim on account of variation of quantities of these items/non execution of any of the above items and contractor shall be paid for at as quoted rates only for the parts actually replaced. | |||
22 | 6.01 | Pedestal bearing no NTN 205 J (Japan) or equivalent of make SKF /NBC complete all as specified and directed\n | 8 | Each | |
23 | 6.02 | Pedestal bearing no NTN 206 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed | 12 | Each | |
24 | 6.03 | Pedestal bearing no NTN 207 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed | 14 | Each | |
25 | 6.04 | Pedestal bearing no NTN C-211 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed | 8 | Each | |
26 | 6.05 | Mild steel blower shaft, 120cm long and 65 mm dia complete all as specified and directed | 12 | Each | |
27 | 6.06 | Mild steel shaft pulley 8” dia, B section, double groove inner bore 32mm with suitable slot for key complete all as specified and directed | 10 | Each | |
28 | 6.07 | Mild steel shaft pulley 8” dia, B section, three groove inner bore 25mm with suitable slot for key complete all as specified and directed | 10 | Each | |
29 | 6.08 | Mild steel shaft pulley 4” dia, B section, double groove inner bore 25mm with suitable slot for key complete all as specified and directed | 11 | Each | |
30 | 6.09 | Cast copper alloy gate valve 25mm nominal bore, screwed down high pressure, with crutch or butter fly handlecomplete all as specified and directed \n Make : Sant/Zoloto/Leader/BIR | 10 | Each | |
31 | 7 | Dismantling and taking down existing volume control dampers of any description and in any position and material and labour for supplying and fixing new volume control damper, cubical movable louvers, operating mechanism, of the following sizes :- \nNote : Volume control dampers including its frame shall be fabricated and made to shape and size with using 20 gauge MS sheet and flat iron of suitable cross section all as directed by the Engineer-in-Charge. | |||
32 | 7.01 | 600mm x 600mm x 150mm deep\n | 10 | Each | |
33 | 7.02 | 450mm x 450mm x 150mm deep | 10 | Each | |
34 | 8 | Dismantling and taking down existing unserviceable aluminium grill of any description and in any position and material and labour for supplying and fixing new extruded aluminium grill powder coated of size 900mmx250mm/ 750mmx200mm/ 1000mmx200mm/900mmx150mm / 800mmx 950mm complete all as specified. | 20 | Each | |
35 | 9 | Dismantling and taking down existing unserviceable aluminium diffuser of any description and in any position and material and labour for supplying and fixing new aluminium diffuser grill of size 250mmx250mm/ 450mmx450mm/ 500mmx500mm/ 300mmx300mm complete all as specified. | 55 | Each | |
36 | 10 | Dismantling old unserviceable PVC tank of any capacity and Supply and fixing rotational moulded PVC water storage tanks (triple layered), cylindrical vertical with closed top hoisted and fixed in position of capacity 1000 Litres on roof/staging including connecting existing pipe line to new tank with and including new GI nipple/connector complete all as specified. \nMake : Sintex, Dhara,Tuff & Polycon\n | 2 | Each | |
37 | 11 | Dismantling and taking down existing fire dampers of any description and in any position and material and labour for supplying and fixing new fire damper, cubical moveable louvers, operating mechanism, including its frame shall be fabricated and made to shape and size with using 20 gauge MS sheet and flat iron of suitable cross section all as directed by the Engineer-in-Charge. | 8 | Each Job | |
38 | 12 | M & L for servicing/ descaling of Air hot water generator upto 150 KW 3 phase, 415 volts including replacement of burnt heater and calibration testing of all function with including replacement of any defective parts.\nNote:- Replacement of burnt out heater shall be measured and paid for separately under respective item of Sch'A'/ BOQ. | 6 | Each Job | |
39 | 13 | Supply only the following filters suitable for Air handling units of air conditioning plants complete all as specified and directed by the Engineer-in-Charge \n(Make : Dyna, Tenacity, Airtech, Puromatic, Thermodyne, Spetam or equivalent make as approved by the GE)\n | |||
40 | 13.01 | Micro ‘V’ air filter nylon/fabric fibre, media of capacity 5 micron, 98% efficiency of size 550mm x 550mm x 300mm deep. | 30 | Each | |
41 | 13.02 | --ditto – but of size 550mm x 550mm x 150mm deep | 20 | Each | |
42 | 13.03 | Pre-air metallic air filter of 10 micron, 90% efficiency with GI sheet frame of size 620mm x 510mm x 50mm deep | BI01010001010000000000000515BI0100001125 | 30 | Each |
43 | 13.04 | --ditto – but of size 500mm x 400mm x 150mm deep | BI01010001010000000000000515BI0100001126 | 25 | Each |
44 | 13.05 | --ditto—but of size 600mm x 305mm x 50mm deep | BI01010001010000000000000515BI0100001127 | 30 | Each |
45 | 13.06 | --ditto—but of size 610mm x 610mm x 50mm deep | 25 | Each | |
46 | 13.07 | --ditto—but of size 610mm x 450mm x 45mm deep | 25 | Each | |
47 | 13.08 | --ditto—but of size 600mm x 500mm x 45mm deep | 25 | Each | |
48 | 14 | Disconnecting and taking out existing unserviceable strip heater of any description and in any position complete all as specified & directed. | 85 | Each | |
49 | 15 | Supply, fixing and connecting strip heater of 2 KW, 230 volts fin type complete all as specified & directed.\nMake : Daspas or equivalent make as approved by the GE. | 45 | Each | |
50 | 16 | Supply and fixing strip heater 3 KW, 230 volts fin type complete all as specified & directed.\n Make : Daspas or equivalent make as approved by the GE | 40 | Each | |