Name of Work: Material&labor for annual repair&maintenance to Cantt fund water distribution pipe lines&sluice valves etc in Cantt area for year 2020-21
Sl.No.
Item Description
Item Code / Make
Quantity
Units
1
1
Repair and removal of obstruction / blockage / contamination from the water pipe line made of any material. The quoted rate will be inclusive of supply of labour for\n(Size of pipe ) :
2
1.01
300 mm
item1
1
Per mtr
3
1.02
250 mm
item2
1
Per mtr
4
1.03
200 mm
item3
1
Per mtr
5
1.04
150 mm
item4
1
Per mtr
6
1.05
100 mm
item5
1
Per mtr
7
1.06
80 mm
item6
1
Per mtr
8
1.07
50 mm
item7
1
Per mtr
9
1.08
25 mm
item8
1
Per mtr
10
1.09
12 mm
item9
1
Per mtr
11
2
Laying of water pipe line supplied by the department in the Cantt area inclusive of excavating the trenches , laying the pipe line , Jointing the same by joints required supplied by the department .Refilling the trenches etc\n(Size of pipe )
12
2.01
300 mm
item10
1
Per mtr
13
2.02
250 mm
item11
1
Per mtr
14
2.03
200 mm
item12
1
Per mtr
15
2.04
150 mm
item13
1
Per mtr
16
2.05
100 mm
item14
1
Per mtr
17
2.06
80 mm
item15
1
Per mtr
18
2.07
50 mm
item16
1
Per mtr
19
2.08
25 mm
item17
1
Per mtr
20
2.09
12 mm
item18
1
Per mtr
21
3
Monthly supply of labor for greasing the Sluice Valves fixed on water distribution mains . The work involves opening of the Sluice Valve of any material , greasing of the parts , Changing the warn out nut bolts , rubber packing etc if damaged and refitting (exclusive of Check Nut and spindle)\n(Size of Sluice Valve)
22
3.01
300 mm
item19
1
Per No
23
3.02
250 mm
item20
1
Per No
24
3.03
200 mm
item21
1
Per No
25
3.04
150 mm
item22
1
Per No
26
3.05
100 mm
item23
1
Per No
27
3.06
80 mm
item24
1
Per No
28
3.07
12 mm
item25
1
Per No
29
4
Excavation for laying of pipe line of different dia for depth up to 1.5 meter & width 0.75 mtr in hard dense soil complete (Size of pipe )
30
4.01
300 mm
item26
1
Per mtr
31
4.02
250 mm
item27
1
Per mtr
32
4.03
200 mm
item28
1
Per mtr
33
4.04
150 mm
item29
1
Per mtr
34
4.05
100 mm
item30
1
Per mtr
35
4.06
80 mm
item31
1
Per mtr
36
4.07
50 mm
item32
1
Per mtr
37
4.08
25 mm
item33
1
Per mtr
38
4.09
12 mm
item34
1
Per mtr
39
5
Excavation for laying of pipe line of different dia for depth up to 0.30 meter & width 0.75 mtr in concrete or hard road surface by brekar or mechanical device etc complete
40
5.01
300 mm
item35
1
Per mtr
41
5.02
250 mm
item36
1
Per mtr
42
5.03
200 mm
item37
1
Per mtr
43
5.04
150 mm
item38
1
Per mtr
44
5.05
100 mm
item39
1
Per mtr
45
5.06
80 mm
item40
1
Per mtr
46
5.07
50 mm
item41
1
Per mtr
47
5.08
25 mm
item42
1
Per mtr
48
5.09
12 mm
item43
1
Per mtr
49
6
Refiiling of excavated stuff for depth up to 1.5 mtr and widet of 0.75 mtr etc complete (Size of pipe )
50
6.01
300 mm
item44
1
Per mtr
51
6.02
250 mm
item45
1
Per mtr
52
6.03
200 mm
item46
1
Per mtr
53
6.04
150 mm
item47
1
Per mtr
54
6.05
100 mm
item48
1
Per mtr
55
6.06
80 mm
item49
1
Per mtr
56
6.07
50 mm
item50
1
Per mtr
57
6.08
25 mm
item51
1
Per mtr
58
6.09
12 mm
item52
1
Per mtr
59
7
Providing and fixing of sluice valve / control vale of approved make in position etc complete as directed (Size of pipe)
60
7.01
300 mm
item53
1
Per mtr
61
7.02
250 mm
item54
1
Per mtr
62
7.03
200 mm
item55
1
Per mtr
63
7.04
150 mm
item56
1
Per mtr
64
7.05
100 mm
item57
1
Per mtr
65
7.06
80 mm
item58
1
Per mtr
66
7.07
50 mm
item59
1
Per mtr
67
7.08
25 mm
item60
1
Per mtr
68
7.09
12 mm
item61
1
Per mtr
69
8
Material required like CID joints , Rubber rings , Packing , Nut bolts , lead filling etc in case of C.I Pipe , cement and water tightening chemicals required if any to complete the repair work in satisfactory manner and testing (Size of pipe )
70
8.01
300 mm
item62
1
Per No
71
8.02
250 mm
item63
1
Per No
72
8.03
200 mm
item64
1
Per No
73
8.04
150 mm
item65
1
Per No
74
8.05
100 mm
item66
1
Per No
75
8.06
80 mm
item67
1
Per No
76
8.07
50 mm
item68
1
Per No
77
8.08
25 mm
item69
1
Per No
78
8.09
12 mm
item70
1
Per No
79
9
Erecting of brick masonry chamber inclusive of following excavation in required size, walls in bricks / concrete block of thicknesss 0.230 m, plastering internally with required PCC for foundation & coping of 0.10 M thick & depth up to 1.2 m or as per site conditions sizes detailed below etc complete
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.