Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #25483718

Supply Of Aicte-Rps-Project

Issued by Boards / Undertakings / PSU · Department of SoEEM, UTD RGPV, Bhopal, Madhya Pradesh
Tender Value
15 Lakhs
Estimated cost
Bid Submission
08 Oct 2020
0 days left
EMD
45000
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Department of SoEEM, UTD RGPV, Bhopal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Aicte-Rps-Project-2 Single User Cfd With Laptop Ncfd Specification: Nautodesk Cfd Ultimate Single User Subscription Software For Lifetime Or Renewal In 5 Years, Cd Containing Cfd Tutorials From Research Perspectives, Free Technical Support For Atleast 3 Years. Nlaptop Specification: N8th Generation Intel® Core™ I7-8550U Processor, Windows® 10 Home Plus Single Language English, 8Gb Ram, 4Gb Graphics, 128Gb Ssd + 1Tb Hard Drive & 1920 X 1080 Fhd Ips Infinity Edge Display, 3×Usb3.0 Port, Ethernet Port, Hdmi Port, High Definition Audio, Microsoft Office 2016, Battery Backup: 6 Hours, 15.6 Inches Screen Size. 3 Thermal Image Camera Ntemperature Range: -10 To 350 °C, Ir Resolution Of 320 X 240 Pixels, Via Integrated Testo Super Resolution Technology 640 X 480 Pixels, Thermal Sensitivity Of 0.06°C, Wireless Communication. N Ntemperature Gun Ntemperature Range: -60 To 500°C, Infrared Accuracy : ±1°C, Resolution: 0.1°C, Low Battery, Laser And Backlight Indication And An Auto Power Off Facility That Turns The Instrument Off After 15 Seconds, Optic / Target Ratio: 11:1. 4 Pyranometer Nrange: 0 To 2000 W / M2, Operating Voltage: 6-12 V Dc, Rechargeable Battery With Backup Of 2-3 Days, Operating Temperature: -40 To 80°C, Lcd Display, Field View: 180°, Data Logging: Minimum 1 Gb Storage, Store Minimum Of 20000 Readings, Adjustable Time Interval Between Readings From 1 Sec To 3600 Sec, Port For Data Transfer To Pc, Software Interface To Monitor The Pyranometer. 5 Digital Hygrometer With Probe Nrange: 0 To 100 % Rh And -20 To + 60 °C Temperature, Accuracy: ±1% Rh And ±0.5 °C Temperature, Resolution: 0.1°C, Ntc Type Sensor, Operating Temperature: -20 To 50°C, Iso Certified, Max. / Min. Values, Hold Button To Freeze Readings, Display Light, Auto Off Function, Aa Battery Powered. 6 Solarimeter Nsolar Irradiation Measuring Range: From 1 W / M2 To 1500 W / M2, Frequency Of The Measure: 2 / S, Accuracy: 5% Of Measurement, Calculation Frequency ( W / M2 ) : 1 / Min ( Average On 60 Seconds ) , Storage Capacity: 31 Days, 44640 Saved Recording Points Noperating Temperature: From -10°C To +50°C, Portable 7 Direct Convective Heat Transfer Coefficient Measuring Device Nfor Measuring The Convective Heat Transfer Coefficient I.E. The Device That Will Measure The Convective Heat Transfer Coefficient In Digital Value 8 Thermal Conductivity Measuring Apparatus Nthermal Conductivity Range: 0.005 To 1800 W / Mk, Temperature Range: -160°C To 1000°C, Accuracy, Repeatability: 5%, 2%, Standard: Iso / Dis 22007-2.2, Materials: Solids, Liquids, Paste And Powder, Directional Measurement : Bulk, Through-Thickness And In-Plane 9 Compact Heat Exchanger N2 Ton And 1 Ton Split Ac 10 Pv / T Panel ( 200 W Each ) Nmono-Crystalline Silicon 200 W Pv Panels, Operating Temperature: -40°C To 80°C, Efficiency Not Less Than 15% . N N 11 Temperature Measurement Channel ( 8 Channel ) Nsuitable For J / K / T Type Thermocouples, 0-400°C Temperature Measurement, Lcd Display, Resolution: 0.01°C, Power Supply 85-265V Ac, 50 / 60Hz, Adjustable Relay Set Points, Data Logging: Minimum 1 Gb Storage, Store Minimum Of 20000 Readings, Adjustable Time Interval Between Readings From 1 Sec To 3600 Sec, , Port For Data Transfer To Pc, Software Interface To Monitor The Data Logger. 12 Constant Temperature Bath Ntemperature Range: 5°C Above Ambient To 120°C, Temperature Control Accuracy + / - 0.10°C, Resolution: 0.1°C, Power Supply 220-230 Volts, Volume: 25 L, Power Rating: 2500 W, Safety Thermostat, Temperature Controlled By Electronic Microprocessor Based Auto Tune Pid Controller With 0.01°C. 13 Nano-Particles Ncopper Oxide ( Cuo ) And Aluminium Oxide ( Al2o3 ) 14 Polycarbonate Sheet Ntransparent, Uv Coated, 90% Light Transmittance, 6Mm Thickness, Multiwall, Temperature Resistance: -5 To 100°C, Thermal Coefficient Of Expansion: 0.065 Mm / M °C, U-Value: 3 W / M 15 Dc Fans Nair Volume: Upto 10 Cfm, Speed: Upto 6000 Rpm, Operating At 1Amp And 12 V Dc, Axial Flow, Blade Material: Plastic 16 Hot-Wire Anemometer With Probe Nair Velocity: 0 To 30 M / S, Temperature: -20 To +80°C, Accuracy: + / -3% Fs, Resolution: 0.01M / S And 0.1°C, Fast Response Time, Lcd Display With Backlight, Thermistor Sensor For Temperature Measurement. 17 Thermocouples Nk-Type Thermocouples, Accuracy + / -1°C, Wire Length 5 M Each, Extension K-Type Thermocouple Wire: 10 M Length 18 Battery N12 Volts Gel Maintenance Free Battery, Li-Ion Solar Battery, Voltage: 12 V, No Of Cell : 6, Estimated Battery Capacity : 4000 Ah, Suggested Battery Capacity @ C10 At 27°C : 4000 Ah, System Configuration : 6 Nos. Cells 4000 Ah Battery ( 4 * 1000 Ah In Parallel String ) , Max. Recharging Current ( A ) : 204, Min. Recharging Current ( A ) : 102, Discharge Ah ( O / P ) : 1600 Ah, Recharge Ah ( I / P ) : 1696 Ah

BOQ

Name of Work: AICTE-RPS-Project
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Items Description
21.01Single User CFD with Laptop\nCFD Specification:\nAutodesk CFD Ultimate single user Subscription software for Lifetime or renewal in 5 years, CD containing CFD tutorials from research perspectives, Free technical support for atleast 3 years.\nLaptop specification: \n8th Generation Intel® Core™ i7-8550U processor, Windows® 10 Home Plus Single Language English, 8GB RAM, 4GB Graphics, 128GB SSD + 1TB Hard Drive & 1920 x 1080 FHD IPS Infinity Edge Display, 3×USB3.0 port, Ethernet Port, HDMI port, High definition Audio, Microsoft Office 2016, Battery backup: 6 hours, 15.6 inches screen size.item11Nos
31.02Thermal Image Camera \nTemperature range: -10 to 350 °C, IR resolution of 320 x 240 pixels, via integrated Testo Super Resolution Technology 640 x 480 pixels, thermal sensitivity of 0.06°C, Wireless communication.\n\nTemperature Gun\nTemperature range: -60 to 500°C, Infrared accuracy : ±1°C, resolution: 0.1°C, low battery, laser and backlight indication and an auto power off facility that turns the instrument off after 15 seconds, Optic/Target ratio: 11:1.item21Nos
41.03Pyranometer\nRange: 0 to 2000 W/m2, Operating Voltage: 6-12 V DC, rechargeable battery with backup of 2-3 days, Operating temperature: -40 to 80°C, LCD Display, field view: 180°, data logging: minimum 1 GB storage, store minimum of 20000 readings, adjustable time interval between readings from 1 sec to 3600 sec, Port for data transfer to PC, software interface to monitor the pyranometer.item31Nos
51.04Digital Hygrometer with Probe\nRange: 0 to 100 % RH and -20 to + 60 °C temperature, Accuracy: ±1% RH and ±0.5 °C temperature, Resolution: 0.1°C, NTC type sensor, Operating temperature: -20 to 50°C, ISO certified, Max./min. values, Hold button to freeze readings, Display light, Auto Off function, AA battery powered.item41Nos
61.05Solarimeter\nSolar irradiation measuring range: from 1 W/m2 to 1500 W/m2, Frequency of the measure: 2 /s, Accuracy: 5% of measurement, Calculation frequency (W/m2): 1/min (average on 60 seconds), Storage capacity: 31 days, 44640 saved recording points\nOperating temperature: from -10°C to +50°C, Portableitem52Nos
71.06Direct Convective heat transfer coefficient measuring device\nFor measuring the convective heat transfer coefficient i.e. the device that will measure the convective heat transfer coefficient in digital valueitem61Nos
81.07Thermal conductivity measuring apparatus\nThermal Conductivity Range: 0.005 to 1800 W/mK, Temperature Range: -160°C to 1000°C, Accuracy, Repeatability: 5%, 2%, Standard: ISO/DIS 22007-2.2, Materials: Solids, Liquids, Paste and Powder, Directional Measurement : Bulk, Through-thickness and In-planeitem71Nos
91.08Compact heat exchanger\n2 Ton and 1 ton split ACitem84Nos
101.09PV/T Panel (200 W each) \nMono-crystalline silicon 200 W PV panels, Operating temperature: -40°C to 80°C, Efficiency not less than 15% . \n \nitem94Nos
111.1Temperature Measurement Channel (8 Channel)\nSuitable for J/K/T type thermocouples, 0-400°C temperature Measurement, LCD Display, Resolution: 0.01°C, Power supply 85-265V AC, 50/60Hz, Adjustable Relay set points, data logging: minimum 1 GB storage, store minimum of 20000 readings, adjustable time interval between readings from 1 sec to 3600 sec,, Port for data transfer to PC, software interface to monitor the data logger.item101Nos
121.11Constant Temperature bath\nTemperature Range: 5°C above ambient to 120°C, Temperature control accuracy +/- 0.10°C, Resolution: 0.1°C, Power supply 220-230 Volts, Volume: 25 L, Power rating: 2500 W, Safety thermostat, Temperature controlled by electronic microprocessor based auto tune PID controller with 0.01°C.item111Nos
131.12Nano-Particles\nCopper Oxide (CuO) and Aluminium Oxide (Al2O3)item125KG
141.13Polycarbonate sheet \nTransparent, UV coated, 90% light transmittance, 6mm thickness, multiwall, Temperature resistance: -5 to 100°C, Thermal coefficient of expansion: 0.065 mm/m °C, U-value: 3 W/mitem1350M2
151.14DC Fans \nAir Volume: upto 10 CFM, Speed: upto 6000 RPM, Operating at 1Amp and 12 V DC, Axial flow, Blade material: Plasticitem146Nos
161.15Hot-wire Anemometer with probe\nAir velocity: 0 to 30 m/s, Temperature: -20 to +80°C, Accuracy: +/-3% FS, resolution: 0.01m/s and 0.1°C, Fast response time, LCD display with backlight, Thermistor sensor for temperature measurement.item151Nos
171.16Thermocouples\nK-Type thermocouples, Accuracy +/-1°C, wire length 5 m each, Extension k-type thermocouple wire: 10 m Lengthitem1615Nos
181.17Battery\n12 Volts Gel maintenance free battery, Li-ion Solar Battery, Voltage: 12 V, No of Cell : 6, Estimated Battery Capacity : 4000 AH, Suggested Battery Capacity @ C10 at 27°C : 4000 AH, System Configuration : 6 Nos. Cells 4000 AH Battery (4 * 1000 AH in parallel string), Max. recharging current (A) : 204, Min. recharging current (A) : 102, Discharge AH (o/p) : 1600 AH, Recharge AH (i/p) : 1696 AHitem171Nos

AI Tender Summary

OUR REF NO 25483718
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 15 Lakhs
LAST DATE 08-10-2020
Authority
Authority Name Rajiv Gandhi Proudyogiki Vishwavidyalay
Work Description Supply Of Aicte-Rps-Project-2 Single User Cfd With Laptop Ncfd Specification: Nautodesk Cfd Ultimate Single User Subscription Software For Lifetime Or Renewal In 5 Years, Cd Containing Cfd Tutorials From Research Perspectives, Free Technical Support For Atleast 3 Years. Nlaptop Specification: N8th Generation Intel® Core™ I7-8550U Processor, Windows® 10 Home Plus Single Language English, 8Gb Ram, 4Gb Graphics, 128Gb Ssd + 1Tb Hard Drive & 1920 X 1080 Fhd Ips Infinity Edge Display, 3×Usb3.0 Port, Ethernet Port, Hdmi Port, High Definition Audio, Microsoft Office 2016, Battery Backup: 6 Hours, 15.6 Inches Screen Size. 3 Thermal Image Camera Ntemperature Range: -10 To 350 °C, Ir Resolution Of 320 X 240 Pixels, Via Integrated Testo Super Resolution Technology 640 X 480 Pixels, Thermal Sensitivity Of 0.06°C, Wireless Communication. N Ntemperature Gun Ntemperature Range: -60 To 500°C, Infrared Accuracy : ±1°C, Resolution: 0.1°C, Low Battery, Laser And Backlight Indication And An Auto Power Off Facility That Turns The Instrument Off After 15 Seconds, Optic / Target Ratio: 11:1. 4 Pyranometer Nrange: 0 To 2000 W / M2, Operating Voltage: 6-12 V Dc, Rechargeable Battery With Backup Of 2-3 Days, Operating Temperature: -40 To 80°C, Lcd Display, Field View: 180°, Data Logging: Minimum 1 Gb Storage, Store Minimum Of 20000 Readings, Adjustable Time Interval Between Readings From 1 Sec To 3600 Sec, Port For Data Transfer To Pc, Software Interface To Monitor The Pyranometer. 5 Digital Hygrometer With Probe Nrange: 0 To 100 % Rh And -20 To + 60 °C Temperature, Accuracy: ±1% Rh And ±0.5 °C Temperature, Resolution: 0.1°C, Ntc Type Sensor, Operating Temperature: -20 To 50°C, Iso Certified, Max. / Min. Values, Hold Button To Freeze Readings, Display Light, Auto Off Function, Aa Battery Powered. 6 Solarimeter Nsolar Irradiation Measuring Range: From 1 W / M2 To 1500 W / M2, Frequency Of The Measure: 2 / S, Accuracy: 5% Of Measurement, Calculation Frequency ( W / M2 ) : 1 / Min ( Average On 60 Seconds ) , Storage Capacity: 31 Days, 44640 Saved Recording Points Noperating Temperature: From -10°C To +50°C, Portable 7 Direct Convective Heat Transfer Coefficient Measuring Device Nfor Measuring The Convective Heat Transfer Coefficient I.E. The Device That Will Measure The Convective Heat Transfer Coefficient In Digital Value 8 Thermal Conductivity Measuring Apparatus Nthermal Conductivity Range: 0.005 To 1800 W / Mk, Temperature Range: -160°C To 1000°C, Accuracy, Repeatability: 5%, 2%, Standard: Iso / Dis 22007-2.2, Materials: Solids, Liquids, Paste And Powder, Directional Measurement : Bulk, Through-Thickness And In-Plane 9 Compact Heat Exchanger N2 Ton And 1 Ton Split Ac 10 Pv / T Panel ( 200 W Each ) Nmono-Crystalline Silicon 200 W Pv Panels, Operating Temperature: -40°C To 80°C, Efficiency Not Less Than 15% . N N 11 Temperature Measurement Channel ( 8 Channel ) Nsuitable For J / K / T Type Thermocouples, 0-400°C Temperature Measurement, Lcd Display, Resolution: 0.01°C, Power Supply 85-265V Ac, 50 / 60Hz, Adjustable Relay Set Points, Data Logging: Minimum 1 Gb Storage, Store Minimum Of 20000 Readings, Adjustable Time Interval Between Readings From 1 Sec To 3600 Sec, , Port For Data Transfer To Pc, Software Interface To Monitor The Data Logger. 12 Constant Temperature Bath Ntemperature Range: 5°C Above Ambient To 120°C, Temperature Control Accuracy + / - 0.10°C, Resolution: 0.1°C, Power Supply 220-230 Volts, Volume: 25 L, Power Rating: 2500 W, Safety Thermostat, Temperature Controlled By Electronic Microprocessor Based Auto Tune Pid Controller With 0.01°C. 13 Nano-Particles Ncopper Oxide ( Cuo ) And Aluminium Oxide ( Al2o3 ) 14 Polycarbonate Sheet Ntransparent, Uv Coated, 90% Light Transmittance, 6Mm Thickness, Multiwall, Temperature Resistance: -5 To 100°C, Thermal Coefficient Of Expansion: 0.065 Mm / M °C, U-Value: 3 W / M 15 Dc Fans Nair Volume: Upto 10 Cfm, Speed: Upto 6000 Rpm, Operating At 1Amp And 12 V Dc, Axial Flow, Blade Material: Plastic 16 Hot-Wire Anemometer With Probe Nair Velocity: 0 To 30 M / S, Temperature: -20 To +80°C, Accuracy: + / -3% Fs, Resolution: 0.01M / S And 0.1°C, Fast Response Time, Lcd Display With Backlight, Thermistor Sensor For Temperature Measurement. 17 Thermocouples Nk-Type Thermocouples, Accuracy + / -1°C, Wire Length 5 M Each, Extension K-Type Thermocouple Wire: 10 M Length 18 Battery N12 Volts Gel Maintenance Free Battery, Li-Ion Solar Battery, Voltage: 12 V, No Of Cell : 6, Estimated Battery Capacity : 4000 Ah, Suggested Battery Capacity @ C10 At 27°C : 4000 Ah, System Configuration : 6 Nos. Cells 4000 Ah Battery ( 4 * 1000 Ah In Parallel String ) , Max. Recharging Current ( A ) : 204, Min. Recharging Current ( A ) : 102, Discharge Ah ( O / P ) : 1600 Ah, Recharge Ah ( I / P ) : 1696 Ah
Basic Detail
Tender No RGPV/RPS/2020/PJ/15
Bidding Type Tender
Location
City Department of SoEEM, UTD RGPV, Bhopal
State Madhya Pradesh
Key Dates
Publish Date 18 Sep 2020
Submission Date 08 Oct 2020
Open Date 09 Oct 2020
Finance
Tender Value 15 Lakhs
Tender Fee 5000
EMD 45000
Exemption Not Available
Document List
BOQ_126347.xls
RPSAICTEComplete.pdf
A4596D80-1A77-4A25-A35F-90349578E063.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 09, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_126347.xls

pdf

RPSAICTEComplete.pdf

html

A4596D80-1A77-4A25-A35F-90349578E063.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders