Comprehensive Maintenance Of Centralized Ac Plant , Summer Cooling Appliances , Water Supply , Stp , Swimming Pool And Allied Works At Zone A Under Age Em Af Gurgaon Of Ge Af Gurgaon, GE (AF) Gurgaon-Haryana

Military Engineer Services-MES has published Comprehensive Maintenance Of Centralized Ac Plant , Summer Cooling Appliances , Water Supply , Stp , Swimming Pool And Allied Works At Zone A Under Age Em Af Gurgaon Of Ge Af Gurgaon. Submission Date for this Tender is 07-10-2020. Air Conditioner Tenders in GE (AF) Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

25477845
Comprehensive Maintenance Of Centralized Ac Plant , Summer Cooling Appliances , Water Supply , Stp , Swimming Pool And Allied Works At Zone A Under Age Em Af Gurgaon Of Ge Af Gurgaon
Open Tender
Indian
Haryana
GE (AF) Gurgaon
07-10-2020

Tender Details

Comprehensive Maintenance Of Centralized Ac Plant , Summer Cooling Appliances , Water Supply , Stp , Swimming Pool And Allied Works At Zone A Under Age Em Af Gurgaon Of Ge Af Gurgaon

Key Value

Document Fees
INR 500 /-
EMD
INR 56000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: COMPREHENSIVE MAINTENANCE OF CENTRALIZED AC PLANT, SUMMER/COOLING APPLIANCES, WATER SUPPLY, STP, SWIMMING POOL AND ALLIED WORKS AT ZONE ‘A’ UNDER AGE E/M (AF) GURGAON OF GE (AF) GURGAON
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for visiting of service engineer/ technician at site and inspecting central Air conditioning Plant of Capacity 3 x 55 TR of respective equipments as listed below:-\n(i) Primary Chiller pump sets along with motors -03 Nos. \n(ii) Secondary Chiller pump sets along with motors -03 Nos.\n(iii) Chiller water pipe lines and its control valves – lot.\n(iv) Electrical operated hot water generator of Cap 63 KW complete with automatic and safety controls such as safety valve, purge valve, high limit cut out, automatic and manual reset, low level cut out stop controller, thermostat, heaters including its control panel-01 No.\n(v) Hot water pump set along with motor and control valves controls provided at each pump set-02 Nos.(vi) Hot water piping, insulation, fittings control valves connected between hot water unit to pump set and pump set to various AHUs-Lot.\n(vii) AHUs complete with accessories such as casing, chilled water coil, hot water coil, any type of air filters, drive motors control panel etc complete 3 Nos AHUs.\n(viii) Controls for AHUs comprising of three way mixing valves with modulating motor, thermostat and humidistat-Lot.\n 3 Each Job
2 1.01 Item No 1.00 contd....\n(ix) Cubical type floor mounted main LT panel consisting control switch gear, starters of pump sets, cooling towers and its single phase preventers, no volt and under volt protection system, meters indication lamps complete-01 No.\n(x) Sub control panel provided for AHUs including controls starter meters and protection system -03 Nos.\n(xi) Central control console panel comprising of ON/OFF push buttons and ON/OFF indication lights -01 No.\n(xii) Chiller /condenser control units/ display unit, Contactors, MCCB/MCB, filters, stainers, drier filters, valve, thermometers, NRV, wiring or other any defect related to units. \nNote item no 1 to 19 : Comprehensive and preventive maintenance shall be carried out by contractor through trained engineers of M/s Blue star limited only. The contracor shall submit the copy of MOU with OEM i.e M/S Blue star limited before commencement of work
3 2 Servicing/Cleaning of Air Handling units (AHU) cooling coils, Blower Fins Air filters with pressuriezed water and chemical etc. to remove dust and scale formation due to natual calamities of central Air conditioning Plant of Capacity 3 x 55 TR complete all directed by Engr-in-Charge. 3 Each
4 3 Supply and Fixing in replacement of PCB (Printed Circuit Board) plate Air cooled chiller unit of 3 x 55 TR AC plant complete all directed by Engr-in-Charge. \nNote- Make of 3 x 55 TR AC plant is Bluestar Air cooled chiller unit. 1 Each
5 4 M&L for N2 Testing, Vacuuming supply and Gas charge R-407 C central Air conditioning Plant complete all directed by Engr-in-Charge. 85 KG
6 5 Supply and Fixing in replacement of Motorized valve 3 way rapid cool transformer, thermostat of AHU in 3 x55 TR central Air conditioning Plant complete all directed by Engr-in-Charge. 3 Each
7 6 Servicing of condensers coils Air-cooled chiller unit of central Air conditioning Plant of Capacity 3 x 55 TR complete all directed by Engr-in-Charge . 2 Each
8 7 M&L for insulation for the pipe line with 13mm thickness closed cell chemically cross linked fire retardant polyethylene foam insulation type W3CF2 of density 30 Kg/cum fixed with rubber based adhesive and covered with aluminum foil on 50-250mm dia pipe complete all as specified and directed by Engr-in-Charge. 20 RM
9 8 Supply and Fixing in replacement of 3TF 47 Contactor in control panel of 3 x 55 TR AC plant capacity complete all directed by Engr-in-Charge 2 Each
10 9 Servicing of 56 TR starter panel of 3 x 55 TR centralised AC plant complete all directed by Engr-in-Charge 1 Each
11 10 Repair of condenser fan motor of 3 x 55 TR centralised AC plant complete all directed by Engr-in-Charge 1 Each
12 11 Supply only Heater coil for Hot Water Generator,rating - 2KW, Make Daspass or equivelent 2 Each
13 12 M&L for visiting of service engineer/ technician at site and inspecting of central Air conditioning Plant of Capacity 3 x 25 TR including Sundays & Holidays for respective equipments as listed below:-\n(i) Chiller pump sets along with motors -03 Nos.\n (ii) Condenser water pump sets along with motors -03 Nos.\n(iii) FRP cooling towers complete with motor, fan, gear box \n(iv) Condenser water pipe lines and its control vales complete-Lot. \n(v) Chiller water pipe lines and its control valves – lot. (vi) AHUs complete with accessories such as casing, chilled water coil, drive motors control panel etc complete 3 Nos AHUs.\n(vii) Controls for AHUs comprising of three way mixing valves with modulating motor, thermostat and humidistat-3 Nos.\n(viii) Cubical type floor mounted main LT panel consisting control switch gear, starters of pump sets, cooling towers and its single phase preventers, no volt and under volt protection system, meters indication lamps complete-01 No.\n(ix) Sub control panel provided for AHUs including controls starter meters and protection system -03 Nos. \n(x) Central control console panel comprising of ON/OFF push buttons and ON/OFF indication lights -01 No.\n(xi) Chiller /condenser control units/ display unit, Contactors, MCCB/MCB, filters, stainers, drier filters, valve, thermometers, NRV, wiring or other any defect related to units. \n 2 Each Job
14 13 N2 Testing vacuuming of 3x25 TR water cooled chiller unit scroll type compressor complete all as directed by Engr-in-Charge. 2 Each
15 14 Descaling of condensers/evaporator coil with chemical cleaning and 20mm Gate valve based on Rep of OEM assessment and working parameters of the 3x25 TR water cooled chiller unit. 2 Each
16 15 Servicing/Cleaning of Air Handling units (AHU) cooling coils, Blower Fins Air filters with pressuriezed water and chemical etc. to remove dust and scale formation due to natual calamities of central Air conditioning Plant of Capacity 3 x 25 TR complete all directed by Engr-in-Charge. 4 Each
17 16 Supply and fixing of iron jali ( Net) for cooling tower of central Air conditioning Plant of Capacity 3 x 25 TR complete all directed by Engr-in-Charge. 1 Each
18 17 Supply and fixing of Expansion valve of centralised Air conditioning Plant of Capacity 3 x 25 TR complete all directed by Engr-in-Charge. 1 Each
19 18 M&L of providing 1.5mm control interlocking wiring of chiller plants with 1 no CT fan, chiller pumps & condenser pumps of centralised Air conditioning Plant of Capacity 3 x 25 TR complete all directed by Engr-in-Charge. 2 Each
20 19 M&L of control contactor auxilary contact block for CT fan & pumps of centralised Air conditioning Plant of Capacity 3 x 25 TR complete all directed by Engr-in-Charge. 2 Each
21 20 Taking down ceiling fan (C/F of any size/make), cleaning its dust properly oiling and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge.\nNote :- (i) The spares like cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional. No extra payments will be done on this account. 150 Each
22 21 Taking down exhaust fan & wall mounting and re-connecting up including provision of cable from ceiling rose to exhaust fan after cleaning all dust complete all as specified and as directed.\nNote :- (i) The spares like nuts & bolts etc if found defective/damage deemed to be replaced and make the fans functional. The rates quoted for the same deemed to be included for the above job. 65 Each
23 22 M&L for Rewinding the stator complete with super enamelled bare copper conductor with the same size and number of turns as that of the old one insulating, varnishing and pre heating for the following :\nNote: Rates are deemed to be inclusive of replacing bush, bearing, armature & capacitor of any type, size & capacity, if required as per fan condition.
24 22.01 (a) Ceiling fan 1200mm/1400mm sweep 150 Each
25 22.02 (b) Exhaust fan 250mm upto 300 mm sweep 40 Each
26 22.03 (c ) Exhaust fan above 300mm upto 450mm sweep 15 Each
27 22.04 (d) Wall mounted fan upto 300mm sweep 10 Each
28 23 Supply and fixing capacitor of 2.5/3.15 MFD complete all as specifeid and directed. 300 Each
29 24 Supply and fixing louvers of Exhaust fan of size 250mm upto 450mm sweep and removing the old, damaged and corroded exhaust fan louvers with new one, complete all as specified and directed. 20 Each Set
30 25 Supply and fixing blades of Exhaust fan of size 250mm upto 450mm sweep as per site and removing the old damaged & corroded exhaust fan blades with new one, complete all as specified and directed. 20 Each Set
31 26 Supply and fixing Exhaust fan support arms, nut bots & washer for exhaust fan of size upto 450mm sweep of any type & size as per site , complete all as specified and directed. 20 Each Set
32 27 M&L for Cleaning and preparing the surfaces of ceiling fan, wall mounted fan, exhaust fan, pedestal fan, removing the grease, carbon dust over the fans and painting with two coats of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan of suitable size all as directed by Engineer-in-Charge. 205 Each
33 28 Disconnecting the inlet , outlet , water connections and electric supply , taking down of Geysers (water heater) of capacity 25/ 50 Ltrs horizontal/vertical of any make/model from existing position and carrying out descaling of inner container , cleaning with suitable chemicals and materials , washing with fresh water, replacment of defective/unserviceable components if any and fixed to its original position complete all as specified and directed. Note: The rate quoted shall include the minors repairs and replacement of minor parts i.e. screw nuts, bolts washers etc .The items replacing herein after shall be measured and paid seperately. 200 Each
34 29 Supply and fixing geyser inner storage tank made of stainless steel of capacity 25Ltrs, complete all as specified and directed.\nNote :- Sample shall be checked at site before procurement to match the existing models. 10 Each
35 30 Supply and fixing heating element 2.00 KW capacity 230 volt suitable for geysers any type ( round/triangular)as per site requirement ISI mark complete all as specified and directed. Make: Venus/Theeta//Bajaj or equivalent.\nNote :- Sample shall be checked at site before procurement to match the existing models. 250 Each
36 31 Supply and fixing thermostat 7"/11" suitable for storage type water heater complete all as specified and as directd.\nNote :- Sample shall be checked at site before procurement to match the existing models. 250 Each
37 32 Supply and fixing PVC insulated PVC sheathed 3 core 4.00 sqmm copper conductor flexible sheathed cable suitable for geysers of any size complete all as specified and as directed. 120 RM
38 33 M&L for preparing external surfaces of water heater, cleaning with emery paper & cloth and painting with two coat of synthetic enamel paint of white colour of approved make with brush and writing MES No. on it of suitable size all as directed. 100 Each
39 34 Supply and fixing Geyser assembly suitable to fix thermostat, heating elements as of the existing size including number nuts, bolt, washer as per site requirement etc complete all as directed.\nNote :- Sample shall be checked at site before procurement to match the existing models. 10 Each
40 35 Taking down old existing unserviceable geysers of any capacity from its position, dismantling and taking out hot water tank, soldering/bracing to arrest the leakage, removing geyser outlet/inlet pipe blockages by removing deposited sediments in geyser tank, reassembling and fixing back in position and testing complete all as specified and as directed.\nNote :- Items required for repairs to geysers such as heating elements, thermostate etc shall be measured and paid separately relevant itmes. 10 Job
41 36 Supply and fixing Bottom inspection chamber cover suitable for 25 Ltrs capacity geyser of any make/model complete all as specified and as directed. 20 Each
42 37 Supply and fixing Indication lamp (red & green) suitable for geyser in round/rectangular shape complete all as specified and as directed. 40 Each
43 38 Supply and fixing of PVC connections 15mm size with PTMT nuts of length 450mm suitable for hot water all as specified and directed by Engineer -in-charge. 30 Each
44 39 M&L for Lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 on 15mm dia pipe complete all as specified and directed. 20 RM
45 40 All as above item No- 39 but on 20 mm dia pipe 50 RM
46 41 All as above item No- 39 but on 25 mm dia pipe 50 RM
47 42 All as above item No- 39 but on 40 mm dia pipe 30 RM
48 43 All as above item No- 39 but on 50 mm dia pipe 40 RM
49 44 S&F Rotational moulded polyethylene water storage tanks 3 layer of 500 lts capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I\nNote: Rate are deemed to be inclusive of transportation charges and shifting of tank on roof top of bldg any floor. 5 Each
50 45 S & F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) of 20mm dia, complete all as specified and directed.\nNote: Thread cutting to inlet pipe and fixing GI reducer of 25x20mm dia is deemed to be included in quoted rate. 5 Each
51 46 S&F in replacement of Heating Element 3.0 KW, 240V, 50Hz ISI mark suitable for dual power solar water heater 100Ltrs capacity, complete all as specified and as directed. 7 Each
52 47 S & F Flat solar plate collector panels suitable for 100LPD solar water heater, free stand type, with copper tubings of suitable size enclosed in toughed glass from top and metal sheet base with back ground painted with black colour and PUF insulated of size as per site requirment, complete all as specified and directed by EIC. \nNOTE: \n1) Panel should be BIS and CEC approved.\n2) All accessories required at site for installation is deemed to be included in quoted rate. \n3) Contractor must check size of panel as per existing before procurement. 2 Each
53 48 M&L for servicing of Split type AC capacity 1.5 ton / 2.0 ton , cleaning of Indoor / outdoor unit, cooling /condensing coil , reinsulation of refrigerant tubing , replacement of worn out spare parts of AC & checking wiring and renewing side and straight thimble, material for soldering (LPG can, breezing rod, breezing power), drain out pipe of required length as per site, fastner, nut bolts etc for complete all as specified and as directed.\nNote: Quoted rate deem to included brass nut and brass end caps, brass nuts, brass coupler nuts and brass gas refilling valve of any size and type. Worn out spare parts will be measured and paid separately under respective items of the Schedule. 64 Each
54 49 M&L for detecting the cause of leakage by nitogen gas flash method or soap method in any type/capacity1.5 ton/2 Ton of AC in position and ensuring the complete system leak proof, by solderinng and brazing and charging full or top up with refrigerant gas (R-22 & R-410a) with appropriate quantity as per site including testing for smooth functioning complete all as specified and as directed.\nNote:\n(i) Refilling and toping up of refrigenrant (R-22 & R-410a) (any type and any quantity) as required on site is deemed to be included in quoted rate. \n(ii) T&P, Nitogen (any qty) required site to work on height and soldering & brazing is deemed to be included in quoted rate.\n(iii) Demounting of units (indoor and outdoor) from their position or from height and refixing back at height is deemed to be included quoted rate. Contractor has to arrange for its own labour & T&P for demounting & refixing. No extra payment will be done for demounting & refixing. \n 5 Each
55 50 M&L for rewinding of the blower motor 1/6,1/5,&1/8 HP of AC any type /capacity with same gauge super enamelled copper wire complete including taking out old unserviceable winding kit complete all as specified and as directed. 2 Each
56 51 M&L for rewinding of the outdoor fan any type /capacity ((upto 1/13 HP, 800 rpm, 57 watt) thermally protected with same gauge super enamelled copper wire complete including taking out old unserviceable winding kit complete all as specified and as directed. 2 Each
57 52 Supply and fixing outdoor fan Blade for AC upto 2 ton as per site, complete as directed.\nNote: Sample shall be checked at site before procurement to match the existing models. 2 Each
58 53 Supply and fixing starting relay of existing makes and capacity duly ISI marked for AC W/T and split type 1.5/2 Ton capacity as per site requirement, complete all as specified and as directed. 2 Each
59 54 Supply and fixing starting capacitor of existing make and capacity (40/60 & 80/100mfd) duly ISI marked for window type A/C 1.5 ton and split type AC 2 ton complete all as specified and as directed. 5 Each
60 55 Supply and fixing three state running capacitor of existing make and capacity (50/6, 45/5 & 36/6mfd) duly ISI marked for window type A/C 1.5 ton and split type AC 2 ton complete all as specified and as directed. 4 Each
61 56 Supply and fixing refrigerant tubing for suction /discharge of (5/8, 1/4, & 1/2 )including insulation tubing all as per site requirement and as directed by Engr-in-Charge. 40 RM
62 57 Supply and fixing of capacitor 10 Mfd blower motor ISI marked complete all as specified and as directed. 10 Each
63 58 S&F PCB card, board type/box type (2 PCB cards fabricated in one box) suitable for existing split type AC 1.5/2 Tone AC of any make/model complete all as specified and as directed. 5 Each
64 59 Supply and fixing allen key type hand shut valve suction for split AC 1.5/2 Toncomplete all as specified and as directed. 2 Each
65 60 Ditto- but allen key type hand shut valve discharge 2 Each
66 61 S&F in replacement of cooling coil of indoor split type AC 1.5/2.0 Ton capacity complete all as per existing make and model 1 Each
67 62 Supply and fixing Split AC Remote (for any make AC) as per model on site.\nNote: Sample shall be checked at site before procurement to match the existing models. 2 Each
68 63 M&L and T&P (any type) for shifting of Split AC of any capacity both indoor, outdoor & its connected accessories (like drain out pipe, copper tubing, frame etc.) by properly demounting from one location and re-fixing it in other location as per user requirement including cutting hole and removing old copper pipes and using same for the new location and testing/commisioning after making proper connections by deploying sufficient labour and tool, complete all as specified and directed by EIC.\nNote:- \n(i) Any type of civil work involve in shifting is deemed to included in quoted rate.\n(ii) Shifting can be on same floor or to higher floors or any other location, no extra payment will be made for labour and transportation.\n(iii) Cost of refrigerant gas charging of unit (full or top up) is deemed to be included in quoted rate.\n(iv) Any extra item required at site due to difference in location will be measured in relevant item. 5 Each job
69 64 Taking down old u/s indoor unit along with connected accessories and Supply, intallation, testing and commissionging of new indoor unit of split type AC of capacity 1.5Ton including all connections.\nNote: Base frame of indoor unit, remote as per new unit PCB card, gas refilling if leaked during installation, intallation charges and other connected work is deemed to be inclucive of rates. 1 Each
70 65 Ditto as Item No: 64 above but capacity 2 ton. \n 1 Each
71 66 Supply and fixing Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 20 Amp complete. 2 Each
72 67 Supply and labour for charging of Refrigerant gas R-22 in cooling appliances of any type and capacity, complete all as specified and directed.\nNote: Labour cost for charging is deemed to be included in quoted rate. Since R-22 is flammable & exposive gas, contractor has to make sure for the safety and take adequate safety measure for technicians/ labour during charging gas. Deptt will not be responsible for any accident nor liable to pay any compensation to victim or contractor. 30 Kg
73 68 M&L for servicing of room desert cooler of any make size by cleaning, oiling & greasing, checking of defects and rectifying unserviceable switches, control switch etc adjusting and setting for work including complete electric wiring with 3 core flexible cable plug top and testing complete all as specified and as dirceted by Engr-in-Charge. 90 Each Job
74 69 M&L for rewinding of fan motor of desert cooler with super enamelled copper wire of existing gauge or gauge as approved by Engineer-in-Charge complete all as specified and as directed.\nNote: replacement of bush bearing is deemed to be included in quoted rate. 30 Each
75 70 M&L for replacement of tullu pump submersible type for desert cooler having, 2mtrs head, 500l/h discharge rate, 25 watts, single phase, complete all as specified and as directed. 60 Each
76 71 Supply and fix in replacement of New fan motor type of 100watts, copper winding, Class E insulation, 1500 rpm, steel shaft, including capacitor of 4 mfd for desert coolers complete all as specified and as directed.\n 40 Each
77 72 Supply and fixing in replacement of capacitor 4 Mfd blower motor & desert cooler motor ISI marked complete all as specified and as directed. 100 Each
78 73 M&L for plastic distributor 3 way of superior quality as per site requirement complete all as specified and as directed. 45 Each
79 74 M&L for PVC pipe 15 mm dia for desert cooler for inside connection of superior quality complete all as specified and as directed. 32 RM
80 75 S&F desert cooler grasspad suitable for cooler of capacity 4000 cum/hrs & dimension of pad not less than complete all as sepcified and directed. 125 Set of 3
81 76 M&L for painting of cabinet body of room cooler with one coat of red oxide paint and two coats for desert cooler water tank with black enameled paint and outer body with smoke grey paint after preparation of surface complete all as specified and as directed. 90 Each job
82 77 Supply and Fixing Butterfly valve of 100mm dia complete all as specified and directed. Make: Audco (L&T) 1 Each
83 78 Supply and Fixing Butterfly valve of 50mm dia complete all as specified and directed. Make: Audco (L&T) 1 Each
84 79 Supply and fixing DOL starter along with auxillary block (Make: L&T cat: MNX A2) suitable for filteration pump of capacity 5HP along with wiring, complete all as specified and directed. 1 Each
85 80 Supply and Fixing thermal relay of 4-10 Amp range complete all as specified and directed, along with wiring, complete all as specified and directed. 1 Each
86 81 Supply and fixing single phase preventer suitable for 5HP pumpset along with wiring complete all as specified and directed. 1 Each
87 82 M & L for Fully Automatic Star delta Starter In sheet Enclosure Type MU-2F Motor rating AC-3,Duty 415v, 50 Hz 3 Phase to 15 HP Motor, Relay range of 013-21 A Cat No.SS SS95984 with auto, manual & bypass mode as per existing after taking out old U/S. Make: L&T/havells/GE. 1 Each
88 83 Testing of Water Samples for Chemical, bacteriological & metal analysis as mentioned below from User end and from the nearest point of OHT tank or as directed by Engineer-in-charge during delivery time for each month complete all as directed.\n(a) PH\n(b) Specific Conductivity\n(c) Free Chloride (CL)\n(d) Total Harness as Ca CO3\n(e) Iron as (FE)\n(f)  Arsenic (AS)\n(g) Total dissolved solids \n(h) Coliform\n(j) E. Coli \n(k) Colour\n(l) Odour\n(m) Taste\n(n) Floride\n(o) TDS\n(p) Turbidity\nNote :-\n(a) Sample of Water for the above media test are to collected in transparent sterlized container/Jar/bottle (to be arranged by contractor) separately for each test against each pump houses. (Hygienically clean bottles) and proper sealing must be done by contractor. \n(b) Sample of water to be collected before and after treatment shall be forwarded to Govt Lab approved & NABL accredited Lab for testing within spitulated time frame. No Extra payment will done for transportation charges.\n \n\n\n 4 Each Job for 3 Nos sample
89 84 Supply only Altoch GP granuals all as specified and as directed by Engineer -in-charge. 300 Kg
90 85 M&L of Run Lead joint for spigot and socketed pipes and fittings of 100 dia bore. Complete all as specified and directed. 10 Each
91 86 Ditto item No 85 but of 150 dia bore. Complete all as specified and directed. 10 Each
92 87 Ditto item No 85 but of 250 dia bore. Complete all as specified and directed. 10 Each
93 88 M&L of Run wool joint for spigot and socketed pipes and fittings of 100 dia bore. Complete all as specified and directed. 10 Each
94 89 Ditto item No 88 but of 150 dia bore. Complete all as specified and directed. 10 Each
95 90 Ditto item No 88 but of 250 dia bore. Complete all as specified and directed. 10 Each
96 91 M&L of rubber gasket joint for spigot and socketed pipes and fittings of 100 dia bore. Complete all as specified and directed. 10 Each
97 92 Ditto item No 91 but of 150 dia bore. Complete all as specified and directed. 10 Each
98 93 Ditto item No 91 but of 250 dia bore. Complete all as specified and directed. 10 Each
99 94 M&L for Dewatering OHT and making surface free from fungi by scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surfaces of RCC over head tanks (bottom & wall) by using brushes and bleaching powder and other cleaning materials as required and applying two coats of lime wash inside the surface of the tanks including writing the words " MILITARY ENGINEER SERVICES, TANK CAPACITY, DATE OF CLEANING AND DUE DATE OF CLEANING" in capital letters of suitable size on outside visible place of OH tank with synthetic enamel white paint over black back ground of 50,000 Gallons water tank complete all as specified and directed. 2 Each Job
100 95 M&L for Dewatering PIT UG sump and making surface free from fungi by scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surfaces of RCC over head tanks (bottom & wall) by using brushes and bleaching powder and other cleaning materials as required and applying two coats of lime wash inside the surface of the tanks including writing the words " MILITARY ENGINEER SERVICES, TANK CAPACITY, DATE OF CLEANING AND DUE DATE OF CLEANING" in capital letters of suitable size on outside visible place of OH tank with synthetic enamel white paint over black back ground of 1.0 lakhs litres water tank complete all as specified and directed. 2 Each Job
101 96 M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surfaces of HDPE storage tanks (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required including writing the words " TANK CAPACITY AND DATE OF CLEANING" in capital letters of suitable size on outside visible place of OH tank with synthetic enamel white paint over black back ground of following capacities complate all as specified and directed by Engineer in charge.
102 96.01 (a) up to 500 Ltrs capacity 200 Each
103 96.02 (b) 501 Ltrs to 1000 Ltrs capacity 100 Each
104 96.03 (c) 1001 Ltrs to 2000 Ltrs capacity 20 Each
105 97 S&F in replacement of gun metal gate valve (heavy duty) with iron wheel head screwed both ends for iron pipe of 20 mm dia bore complete all as specified & directed by Engineer - In - Chrage.Make: Kartar/Sant/Leader 20 Each
106 98 All as per Item No 97 above , but 25 mm dia complete. 30 Each
107 99 All as per Item No 97 above , but 40 mm dia complete. 10 Each
108 100 All as per Item No 97 above , but 50 mm dia complete. 15 Each
109 101 Supply and fixing of GI Tubing , medium grade , 20 mm dia bore in trenches or on wall/ceiling/floor complete all as specified & directed by Engineer - In - Chrage.Make: Jintal/TATA/Parkash\nNote: excavation, return & refilling is deemed to be included in quoted rates. 50 RM
110 102 All as per Item No 101 above , but 25 mm dia complete. 100 RM
111 103 All as per Item No 101 above , but 40 mm dia complete. 50 RM
112 104 All as per Item No 101 above , but 50 mm dia complete. 50 Each
113 105 S&F jointing and testing of cast iron sluice valve ISI mark (PN-1.6) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts washers and gaskets including taking down unserviceable sluice valve complete all as specified of size 80mm complete all as specified. Make: Kirloskar/Kartar 1 Each
114 106 All as per Item No 105 above , but 100 mm dia complete. 2 Each
115 107 All as per Item No 105 above , but 150 mm dia complete. 2 Each
116 108 All as per Item No 105 above , but 250 mm dia complete. 1 Each
117 109 S & Fin replacement of Non return valve size 80 mm dia , including rubber fibre board gasket joint at both ends with nuts , bolts & washers including necessary earth work complete all as specified and directed by Engineer-In-Charge.Make: Kirloskar / Leader/ kartar 1 Each
118 110 All as per Item No 109 above, but 100 mm dia complete. 1 Each
119 111 M&L for construction of Valve pit chamber 90 cmx90cm (inner dimension) and 90 cm deep , from the top of MS cover fixed on PCC Base, 75mm thick in 1:2:4 type B1 top cover shall be of 3 mm thick MS Sheet with locking arrangement of pad lock of 50mm size including brick work with sub class"B" bricks in CM 1:4 including 15 mm thick plaster in CM 1:4 (internally and externally) and necessray earth work in any ype of soil including returning filling in and disposal of surplus oil to a distance n exc 50 mtrs and 150 mm thick PCC 1:4:8 , type D-2 , using 40mm graded stone aggregates as in floor complete all as specified and directed by Engineer - In - Charge. \nNote: Exacavation, returning, refilling etc is deemed to be included in quoted rate. 2 Each Job
120 112 M&L for Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for CI pipe upto 150 mm dia, complete all as specified and directed.\nNote: Quoted Rate are inclusive of technician, labour, T&P, nut bolt washer of any size and qty required at site. 30 Kg
121 113 Same as item No: 112 but for CI pipe upto 200mm dia to 300mm dia pipe 25 Kg
122 114 Same as item No: 112 but flanged CI pipe fitting upto 150mm dia pipe 20 Kg
123 115 Same as item No: 112 but flanged CI pipe fitting upto 200mm dia to 300mm dia pipe 15 Kg
124 116 M&L for Repacking stuffing box of sluice valve of 100mm spindle including taking apart and reassembling, complete all as specified and directed.\nNote: Nut, bolt, washer, packing, glands, gasket etc requierd at site is deemed to be included in quoted rates 10 Each
125 117 Same as item no: 116 but for 150mm dia sluice valve. 5 Each
126 118 Same as item no: 116 but for 250mm dia sluice valve. 3 Each
127 119 M&L for Taking out sluice valves of 100mm dia refacing, regrinding and refixing complete all as specified and directed.\nNote: Nut, bolt, washer, packing, glands, gasket etc requierd at site is deemed to be included in quoted rates 10 Each
128 120 Same as item no: 119 but for 150mm dia sluice valve. 5 Each
129 121 Same as item no: 119 but for 250mm dia sluice valve. 3 Each
130 122 Labour only for lifting /taking out the Fresh water submersible pump set and motor of capacity 10 to 15 HP including CI column pipe of any bore by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from bore of depth upto 60 meter and lowering back the pump after repairing /Checking loose connection including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut ,Bolts,washers/packing to the existing header without any leakage complete all as directed.\n Note for :- Rate are deemed to be inclusive for jointing of Submersible Cable upto 6mtr, Steel wire of suitable gauge tied with motor before lowering down upto the depth of motor, reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete all as specified.\n 4 Each \njob
131 123 Ditto item No 122 but the motor capacity upto 7.5 HP. 2 Each Job
132 124 M&L for rewinding of electric motor (submersible & monoblock) 3HP 50 HZ 400/415 volts of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed . 1 Each
133 125 M&L for rewinding of electric motor 5HP to 7.5 HP , 50 HZ 400/415 volts of non clogging/ mono block/centrifugal elctric motor of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed . 1 Each
134 126 M&L for rewinding of fresh water Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire, including replacement of thrust plate , thrust block housing , bush, sleeves. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 07 Meter, Capacity of motor 10 HP to 15 HP complete all as specified and as directed . 4 Each
135 127 M&L for repairing and testing of pump centrifugal/mono block/non clogging upto 5 HP of any make and type including welding work, turning, re-metaling of shaft bush bearing, key and other such accessories etc required to make pump functional and testing on load complete all as specified and as directed . 1 Each
136 128 M&L for repairing of pump, bucket type for submersible pumpset suitable for 10HP to 15HP of 13 stages including servicing/repair/replacement of each bucket, sleeves, brass impeller, Thrust plate, bush - bearing of suitable size, glands, rotor rod etc. complete all as specified and directed. 4 Each
137 129 M&L for maintenance of solar LED street lights - 24 Nos (make: Aura). Replacement or repair to LED luminaire of 30 watts, including repair to its driver, PCB card, sensor, solar photo voltic panel/cell, inbuild Li-on batteries and any physical damage cause to panels, pole, hoding strip, GI supporter strips etc (fabrication of GI/MS frame on site and repairing tilted frames) by deploying authorised rep of Aura solar lightings, complete all as specified and directed\nNote: (i) Replacement of spare parts is included in quoted rates including battery, driver, PCB card, sensor, connecting terminals,photo voltic cell/panel, LED luminaire of 30 watt.\n(ii) contractor has to arrange T&P & labour for fabrication on site, repairing any physical damage to Solar street ights.\n(iii) Visiting charges by technicians is any nos of time included in quoted rates.\n(iv) Panelity of Rs. 1000 per light per day will recovered from contractor if light not found serviceable. 8 Per Month
138 130 Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. 40.5 Cum
139 131 Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed. 40.5 Cum
140 132 Complete overhauling and recommissioning of STP of capacity 150 KLD including dismantling the choked MS pipes, SS riser pipes, air diffusers in equalisation tank and MBBR tanks and refixing the same, providing with test report of treated water from govt. approved lab before completion of job. On completion providing training to the operators for operation of STP. Note: The plant will be taken over after successful completion of trial run of 3 days Note: The rates also include complete cement paint to concrete sructures 1 Each
141 133 Repair and overhauling incl Dismantling/taking down all electrical and mechanical connection of twin lobe blowers model No (Make:- Usha) capacity ,pressure 0.37 kg/cm and servicing hole body, change gear oil/lubricant and V belt,overhauling of the same including refixing and testing complete all as specified and directed. Note;- spare parts and gera oil/lubricant shall be measured and paid including supply of following materials: 2 Each
142 133.01 (a) servo gear oil super 90, Make indian oil
143 133.02 (b) Bearing as per sample for air blowers model No -610FS (Make:- Usha)
144 133.03 (c) Gasket kit as per sample for air blowers model No -610FS (Make:- Usha)
145 133.04 (d) Oil sealas per sample for air blowers model No -610FS (Make:- Usha)
146 133.05 (e) V-belt as per sample for air blowers model No -610FS (Make:- Usha)
147 133.06 (f) Air filters per sample for air blowers model No -610FS (Make:- Usha)
148 134 Taking down Turbine motor of 5/7.5 HP capacity from existing position for carring out repair works and re-assembling ,re-installing the pump set in original position for the following capacity: Note:- spare parts ,winding wire required for renewal will be paid seperately 2 Each
149 135 Supply and fixing including cutting and welding in repair MS flanges 80 mm alongwith rubber gasket, nut bots and washers complete as per specified 2 Each
150 136 Supply and fixing including cutting and welding in repair MS flanges 50 mm alongwith rubber gasket, nut bots and washers complete as per specified 2 Each
151 137 Supply and fixing including cutting and welding in repair MS flanges 40 mm alongwith rubber gasket, nut bots and washers complete as per specified 2 Each
152 138 Pumping out sewage water from sludge drying beds and disposing the same as directed and a distance exc 50 mtr and nexc 100 mtr (volum of water to be measured and paid) incl Hiring of pump set of required capacity complete all as specifiedand as directed for 150 KLD plant 1 Each job
153 139 S&F as in repair Four core 4 sqmm cable PVC insulated multi-straned copper conductor drawn through in existing metallic Conduit/GI pipe surface/concealed conduit of 25 mm dia and connection at both ends with copper legs, colour code for phase Red /Yellow/Blur for neutral Black and for earth green complete all as specifiedand as directed 25 RM
154 140 S&F as in repair Four core 2.5 sqmm cable PVC insulated multi-straned copper conductor drawn through in existing metallic Conduit/GI pipe surface/concealed conduit of 25 mm dia and connection at both ends with copper legs, colour code for phase Red /Yellow/Blue for neutral Black and for earth green complete all as specifiedand as directed 25 RM
155 141 Dismantling, cleaning and refixing in repairs mild steel water tubing complete with all fittings size 40mm bore medium grade ISI marked IS-1239-1976 pipe laid in trenches on walls or in any position complete all as directed by Engr-in-charge. 16 RM
156 142 Dismantling, cleaning and refixing in repairs mild steel water tubing complete with all fittings size 50mm bore medium grade ISI marked IS-1239-1976 pipe laid in trenches on walls or in any position complete all as directed by Engr-in-charge. 12 RM
157 143 Dismantling, cleaning and refixing in repairs mild steel water tubing complete with all fittings size 80 mm bore medium grade ISI marked IS-1239-1976 pipe laid in trenches on walls or in any position complete all as directed by Engr-in-charge. 12 RM
158 144 Dewatering the equalisation tank capacity 40000 Ltrs (Approx) with the help of mud pump and removal of complete sludge and cleaning inside, descaling with wire brush internal surface of tank and scraper unit floculator and washing fresh water two times with bleaching powder all as specified & directed by Engr-in-Charge. Note:- 1. Make a temporary arragement of sewage disposal by existing adhoc pump to approx 100 mtrs far from STP. 2. Work is in running condition and the contractor is required to take necessary safety precautions and arrange safety mask, hand gloves etc 3. Arragement of mud pump set for dewatering at his own expense. Quoted rate is deemed to be inclusive of the above aspect. 1 Each job
159 145 M& L for dewatering with help of mud pump and Manning for cleaning of MBBR tanks of compartments of each 1.6m square and height 6m size and removing all the settled solid sludge or any other type of material and through out side MD Land and as directed by Engr-in-Charge. 2 Each job
160 146 M & L for dewatering with help of mud pump and Manning for cleaning of tube settler tank of size 3m x 2mx 3m height (approx) and removing all the settled deposited fungus or any other type of bio-fouling and all as directed by Engr-in-Charge. 1 Each job
161 147 Repair and Servicing of electric motor of 2 H P/ 1 HP and two coat enamel painting of all mattel parts complete all as directed by Engineer-in-Charge. 4 Each job
162 148 M&L for taking out carbon filter from ACF tank and replacing with fresh carbon/ anthracite chemically treated incl servicing and cleaning the filters complete all as directed 1 Each job
163 149 M&L for taking out sand bed from cylinderical DMF tank and replacing the same with chemically treated filter beds viz. pebbles, sand etc chemically treated. 1 Each job
164 150 Supply and fix submersible cable flat 3 core copper 6 sqmm all as specified & directed by Engr-in-Charge. 12 RM
165 151 M&L painting of water treatment plant MBBR tanks, tube settler tank, filter columns, pipe line and induction motor of following sizes including scraping of old paint from GI pipe and induction motor with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey by using spray gun complete all as specified and directed :-\n(a) 40mm dia\n(b) 50mm dia \n(c) 80mm dia (Total length of all pipes approx 60m) 1 Each job
166 152 Supply fixing, testing and commissioning in-replacement of dosing pump with accssories including lead tubing , connecting nuts injection check valve , clay weight and ferrules consisting of 40 ltr -100 ltr PE/FRP tank with PE/FRP lid and level gauges, mounted on tank all as specified and directed by Engineer -in-charge . Make - Edose 1 Each
167 153 Material and labour for MBBR media made of poly propylene with virgin plastic UV stabilized milky white specific gravity 0.95 to 0.98 complete all as specified. 4 Cum
168 154 Material and labour for Tube Settler modules made of PVC complete all as specified including dismantling and taking out the old damaged tube settler media 3 Cum