Repairs To Flooring , Certain Rcc Works , Plastering , Leakage Seepage , Joineries , Replacement Of Ac Sheet False Ceiling , Aluminium Works , Plumbing , Guniting And External Periodical Services And Internal Wiring To Certain Md Accn At Af Stn A, GE (AF) Gurgaon-Haryana

Military Engineer Services-MES has published Repairs To Flooring , Certain Rcc Works , Plastering , Leakage Seepage , Joineries , Replacement Of Ac Sheet False Ceiling , Aluminium Works , Plumbing , Guniting And External Periodical Services And Internal Wiring To Certain Md Accn At Af Stn A. Submission Date for this Tender is 07-10-2020. Electrification Work Tenders in GE (AF) Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

25476834
Repairs To Flooring , Certain Rcc Works , Plastering , Leakage Seepage , Joineries , Replacement Of Ac Sheet False Ceiling , Aluminium Works , Plumbing , Guniting And External Periodical Services And Internal Wiring To Certain Md Accn At Af Stn A
Open Tender
Indian
Haryana
GE (AF) Gurgaon
07-10-2020

Tender Details

Repairs To Flooring , Certain Rcc Works , Plastering , Leakage Seepage , Joineries , Replacement Of Ac Sheet False Ceiling , Aluminium Works , Plumbing , Guniting And External Periodical Services And Internal Wiring To Certain Md Accn At Af Stn Arjangarh U

Key Value

Document Fees
INR 500 /-
EMD
INR 62900.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIRS TO FLOORING, CERTAIN RCC WORKS, PLASTERING, LEAKAGE/SEEPAGE, JOINERIES, REPLACEMENT OF AC SHEET & FALSE CEILING, ALUMINIUM WORKS, PLUMBING, GUNITING AND EXTERNAL PERIODICAL SERVICES AND INTERNAL WIRING TO CERTAIN MD ACCN AT AF STN ARJANGARH UNDER AGE (AF) AYANAGAR OF GE (AF) GURGAON
Sl. No. Item Description Item Code / Make Quantity Units
1 1 B/R Works\nTaking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each all as specified and directed by Engineer - in – Charge. 15 Each
2 2 Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each and all as specified and directed by Engineer - in - Charge. 10 Each
3 3 Taking down shutters of any description not exceeding 1.00 Sqm each all as specified and directed by Engineer - in – Charge . 20 Per leaf
4 4 Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.0 Sqm all as specified and directed by Engineer - in - Charge . 20 Pear Leaf
5 5 Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness ( below or above ground level) complete all as specified and as directed. 35.5 Cum
6 6 Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land, complete all as specified. 250 Sqm
7 7 Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified. 100 Sqm
8 8 Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified. 100 Sqm
9 9 Rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces (such as top & sides of chajjas, beams, balcony ceiling etc.) finished even and smooth without using extra cement, complete all as specified and directed. 50 Sqm
10 10 S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified and directed by Engineer - in - Charges. 35.739 Sqm
11 11 S & F flush shutter 35mm thick solid core construction with block board core and plywood face panels commercial type on both sides with lipping / frame to match all as specified and directed by Engineer - in - Charge. 35.739 Sqm
12 12 M&L for Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of single side prelaminated PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification complete all as specified and as directed by Engineer-in-Charge. 17.226 Sqm
13 13 S&F Factory made PVC solid door frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of 5 mm thick plain colour PVC sheet cut at corner and jointed with 02 Nos., 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided throughout the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical member & minimum 02 Nos. for horizontal member), complete all as specified. 70.2 RM
14 14 S & F mild steel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long all as specified and directed by Engineer - in – Charge . 130 Each
15 15 S & F mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm all as specified and directed by Engineer - in - Charge . 35 Each
16 16 S & F mild steel, 300mm, ordinary rat rail rod pattern spring including roller and roller plate complete all as specified and directed by Engineer - in - Charge. 25 Each
17 17 S & F aluminium handle cast type anodised, 125 mm long all as specified and directed by Engineer - in - Charge . 130 Each
18 18 S & F SS butt hinges, medium weight 100mm size all as specified and directed by Engineer - in - Charge . 195 Each
19 19 S & F pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified size of frame 125 x 60mm all as specified and directed by Engineer - in - Charge . 24.9 RM
20 20 M&L Cement concrete 1:3:6 type C–1 filling of pressed steel frame and hold fast blocks etc all as specified and directed by Engineer - in - Charge. 0.5 Cum
21 21 Cutting hole in brick wall built in cement mortar exceeding half brick but not exceeding one brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B – 1 all as specified and directed by Engineer - in - Charge. 60 Each
22 22 S & F mild steel work for hold fasts,wall ties, ,bands, straps clamps, handles for manhole covers etc confirming to Fe- Fe 290grade- E165 all as specified and directed by Engineer - in - Charge. 50 Kg
23 23 Taking down old wooden/steel windows incl grill of any patern and design if any & M&L for factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified 30 Sqm
24 24 Taking down old wooden/steel windows incl grill if any of any patern and design & M&L for factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified 30 Sqm
25 25 Taking down steel/wooden window/vent of any description incl grill if any & M&L for factory made box type steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified 10 Sqm
26 26 S & F mild steel as in framed work as in doors or gates of angles or other section etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (incl for steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing incl MS hinges ,handles ms sheets 0.63 mm thick complete Fe 410-0 all as specified and directed by Engineer - in - Charge. 500 Kg
27 27 S & F in repair framed work such as grills, grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 290grade- E165 all as specified and directed by Engineer - in - Charge. 500 Kg
28 28 Supply and fixing, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead, complete all as specified and directed. 30 Sqm
29 29 Material and labour for preparation of new surfaces of wood and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat pink primer complete all as directed. 30 Sqm
30 30 M&L for preparation of new surfaces of steel or iron work of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer on steel surfaces complete all as specified and as directed by Engr-in-Charge. 30 Sqm
31 31 Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing)removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed 203 Sqm
32 32 First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.16 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles and leveling the floor with PCC 1:2:4 type B0 of required thickness if required to maintain slope etc. , complete all as specified. 50 Sqm
33 33 First quality, Non skid ceramic coloured joint free tiles, 7 to 8 mm thick (square or rectangular) area of each tile exe 0.18 Sqm but n.exe 0.38 Sqm, laid in floors set and jointed with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, and leveling the floor with PCC 1:2:4 type B0 of required thickness if required to maintain slope etc. complete all as specified. 72 Sqm
34 34 All as per item No 33 above but on vertical surfaces such as skirting fixed on and including 10mm thick rendering in cement mortar 1:4 as backing coat complete all as directed by Engr-in-charge. 10 Sqm
35 35 M & L first quality coloured glazed ceramic tiles, fixed in pattern of different colour including border of size 300 x 450 x 7 mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed. Note :- Pattern of the tiles will be decided by GE at the time of execution. 71 Sqm
36 36 Dismantling/removing old damaged worn out APP of any thickness incl screed bed or plastering of any thickness and removing the rubish materials outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete. 1000 Sqm
37 37 Material and labour, 15 mm thick cement plaster in CM (1:4) mixed with WPC as per manufacturer’s instructions @ 3% by weight of cement on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately. 900 Sqm
38 38 Cutting groove in brick wall 75 mm wide and 65 mm deep for inserting APP polymer membrane and shaping horizontal face of groove with cement mortar 1:3, including removal of rubbish outside MoD land, complete all as specified. 45 RM
39 39 Material and labour, water proofing treatment of roof consisting as under:- (a) Applying a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of primer @ 0.30 litre/ sq.m including preparation of roof surfaces (b) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions complete all as specified and directed. 900 Sqm
40 40 All as per Srl item No. 39 here-in-before but on vertical surfaces, using hot blown bitumen having penetration value 30/40 applied 1.20 Kg/ Sq.m over primer @ 0.30 litre/ Sq.m, complete all as specified and directed by Engineer-in-Charge. 100 Sqm
41 41 Preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed. 100 Sqm
42 42 Material and labour preparation of new plastered surfaces and apply two coat of oil bound distmper over a coat of primer, complete all as specified and directed. 150 Sqm
43 43 S&F in repairs stain less steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed together with aluminium anodised mesh 100x100x1.0mm thick fixed tinned tacks or galvanised wire stapple etc as in wire gauzed shutter including repacement of broken wooden beadings as required at site complete all as specified. 30 Sqm
44 44 Hacking out old broken glass (any thickness size, quality or description) from wooden/ steel frames, glazed with putty or fixed with wooden beads/ metal pins complete all as specified and as directed. 20 Sqm
45 45 S & F 3mm thick Sheet glass ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified. Note:- New wooden required for glazing glass in wooden window will be paid for separately. 20 Sqm
46 46 S & F figured glass 3mm thick pin head type and glazing with oil putty and securing with glazing pins not exceeding 0.50 Sqm in each pan complete all as specified and directed by Engineer - in - Charge . 10 Sqm
47 47 Supply and fixing, drapery rod of mild steel 25mm dia, ribbed/fancy type, PVC powder coated, any shade, including set of fixing brackets, for span not exceeding 2m, fixed to wall in repairs, with PVC finols/finnels, connected accessaries, rubber packing, required screws and PVC rawal plugs as required complete all as specified and as directed. 200 RM
48 48 S & F in repairs 600 x 450 mm size beveled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs with chromium plated brass screws and cup washers all as specified and directed by Engineer - in - Charge . 10 Each
49 49 M&L complete removal of existing treatment by scraping down completely on brick wall/concrete surfaces thoroughly, washing, rubbing down with water cleaning the surface upto the entire satisfaction of Engineer-in-Charge and including opening of existing cracks , filling up of "V" cracks with epoxy expandable putty to required depth, making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4incl necessary filling and applying of Birla white putty on entire surfaces to obtain/achieve smooth even surfaces with using sand paper and applying two coat of exterior emulsion paint 100% acrylic of approved colour and shade by accepting officers over and including a coat of primer as per manufacturers instrctions, including necessary scafolding upto 4th floor, complete all as specified and directed by Engineer-in-Charge. 6000 Sqm
50 50 All as per srl item No 48 above but without complete removal and applying one coat of exterior emulsion paint 100% acrylic of make given in item No 1 above on old decorated surface including opening of existing cracks , filling up of "V" cracks with epoxy expandable putty to required depth , making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 complete all as pecified and as directed. preparation of surface . 500 Sqm
51 51 M&L complete removal of existing treatment by scraping down washing rubbing down with water and cleaning the surface up to the entire satisfaction of Engineer-in-Charge and including opening of existing cracks , filling up of "V" cracks with epoxy expandable putty to required depth, making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 applying two coat of oil emulsion over 2 to 3 mm thick birla putty punning complete all as specified or as directed by Engineer-in -Charge. 3000 Sqm
52 52 All as per srl item no 50 here-in-before but without complete removal one coat of Acrilyc washable disteper on old decorated surface including preparation of surface. 1000 Sqm
53 53 M&L complete removal of existing treatment by scraping down completely on brick wall/concrete/plastered surfaces thoroughly, washing, rubbing down with water cleaning the surface upto the entire satisfaction of Engineer-in-Charge and a primer coat of " cemprover of M/S Snocem on entire surfaces and filling the craks/depression/holes etc by putty as directed and making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 than applying two coat of cement base paint coating of approved colour and shade by accepting officers on walls upto 4th floor complete complete all as specified and directed by Engineer-in-Charge. including necessary form work upto 4th floor. 3000 Sqm
54 54 Complete screpping of existing treatment on walls including cornices pilasters steel scrappers , wire brushing, and efforescent salts and treating oil and greasy spots and making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 applying three coat of white wash on walls upto 4th floor complete all as specified and directed by Engineer-in-Charge. and applying three coats of white wash incl prepration of surfaces complete all as spd and as directed. 100 Sqm
55 55 All as per srl item no 54 above but one coat of white wash on ceiling complete all as specified and directed by Engineer-in-Charge 1000 Sqm
56 56 Preparation of old painted surfaces of wall plastered/concrete based material of any description over 10cm width or girth and applying two Coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. 100 Sqm
57 57 Preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth by cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc , filling in crevices and cracks etc with approved filler and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. 100 Sqm
58 58 Ditto all as in item No 57 Above but one coats - ditto- 50 Sqm
59 59 Preparing old painted surfaces of steel and iron surfaces over 10 cm width or girthby cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc , filling in crevices and cracks etc with approved filler and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. 100 Sqm
60 60 Ditto all as in item No 59 Above but one coats - ditto- 50 Sqm
61 61 M&L for averaging 3 mm thick putty and applying one coat of primer complete all as specified and directed by Engineer-in-Charge. 200 Sqm
62 62 Taking down steel tubing 15mm bore and connections including cleaning for refixing or removing to stores complete all as specified and directed by Engineer - in – Charge. 50 RM
63 63 All as per Srl Item No 62 here in before but 20mm bore all as specified and directed by Engineer - in - Charge. 50 Rm
64 64 S & F 15mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. Note : Cutting chases as required shall be measured and paid seperately. 50 RM
65 65 S & F 20mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. Note : Cutting chases as required shall be measured and paid seperately. 50 RM
66 66 Cutting chases, pinning in brick walls, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc; and cuttings chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exceeding 10 cm girth all as specified and directed by Engineer-in - Charge. 50 RM
67 67 S&F in repaires 15mm bore angular stop cock with wall flange , fancy type cast copper alloy with capston head, chromium plated, screwed down high pressure and fixed for iron pipe with C.P. brass connection pipe with union nuts complete with C.P. brass flange including cutting and making good the walls where ever required.complete all as specified and as directed by Engineer-in-Charge. 15 Each
68 68 S & F in repairs bib taps long body 15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified and directed by Engineer - in – Charge 30 Each
69 69 S & F in repairs shower rose 125mm size round shape single flow (ABS Body chrome plated with grey face plate) with rubit cleaning system incl shower arm casted 190 mm long flat shape for wall mounted showers with flange incl fixing to steel pipe or union all as specified and directed by Engineer - in - Charge. 10 Each
70 70 S & F in repair brass chromium plated tubular towel rail 20mm dia “D” type 60 cm long between flanges incldg brackets complete all as specified and directed by Engineer - in - Charge . 10 Each
71 71 S & F in repairs Ist quality vitreous china wash basin, white, flat back, size 550x400mm ) , PVC connections suitable for hot and cold water,bottle trap (with internal partition) 32 mm size with 300mm &190mm long wall connection pipes & wall flange, and fixing withbrackets/bolts including cutting and pinning in etc complete all as specified and directed by Engineer - in – Charge . 5 Each
72 72 Dismantling of cast iron or reiforced concrete drain pipes jointed in cement mortar and taking out from trenches 100 / 75 mm bore (sand cast) all as specified and directed by Engineer - in - Charge . 40 RM
73 73 Material and labour, 100mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, laid in trenches or in floors including necessary excavation and earth work, complete all as specified and directed. 10 RM
74 74 Material and labour, 100mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, fixed to wall with and including mild steel clamps and bolts with washers, complete all as specified and directed. 10 RM
75 75 Material and labour, 75mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, laid in trenches or in floors including necessary excavation and earth work, complete all as specified and directed. 10 RM
76 76 Material and labour, 75mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, fixed to wall with and including mild steel clamps and bolts with washers, complete all as specified and directed. 10 Rm
77 77 Supply and fix in repairs Cast iron floor trap with dia of outlet 100 mm, with CP grating hinge type in kitchen and other situation including PCC 1:2:4 type B1 for setting the trap and jointing to waste pipe including taking out old floor trap , complete all as specified and directed. 5 Each
78 78 Supply and fix in repairs Cast iron floor trap with dia of outlet75 mm, with CP grating with hinge in kitchen and bath etc situation including PCC 1:2:4 type B1 for setting the trap and jointing to waste pipe including taking out old floor trap , complete all as specified and directed. 5 Each
79 79 S & F 100mm bore bends, diminishing pieces or tapers all as specified and directed by Engineer - in – Charge. 4 Each
80 80 S & F 75mm bore bends, diminishing pieces or tapers all as specified and directed by Engineer - in – Charge. 4 Each
81 81 Supply and fix Vitreous China wash down water closet' constellation white colour complete set incl cistern with lid cover fixed in repairs, including connection to wate pipe, flushing pipe, anti-syphonage pipe etc. and making good to floor complete all as specified and directed by Engineer - in -Charge. 2 Each
82 82 Dismantling Asbestos cement sheets (corrugated ,semi corrugated etc) in roof coverings incl rigdes etc complete.. 150 Sqm
83 83 M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws incl taking down old u/s sheet all as specified and as directed. 150 sqm
84 84 Dismantling boarding , any description, fixed in any position with nails complete all as specified and directed by Engineer in Charge. 50 Sqm
85 85 M&L for 4 mm thick Asbestos cement plain building boards,fixed to timber frame work with screws complete all as specified. 50 Sqm
86 86 M&L for second class hard wood plain fillets, square rectangular or triangular in section, clean sawn secured with nails or brads sectional area exceeding 13 & not exceeding 25 Sqcm etc complete all as specified and directed by Engineer-in-Charge. 100 RM
87 87 M&L for 75 mm thick cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregates) as in sub base of path/roads etc complete all as specified and as directed 100 Sqm
88 88 M & L 40 mm thick Cement Conrete1:2:4 type B–1 using 20mm graded stone aggregates flooring finished even and smooth without using extra cement all as specified and directed by Engineer - in – Charge . 500 Sqm
89 89 M&L for coloured, pressed machine presssd pre-cast concrete interlocking coloured paving Block of glass fibre reinfoced vibro compacted any shape and size confirming to IS-15658-2006 of 80 mm thick, M-50 grade to match with grey cement and pigment etc complete all as specified and as directed 100 Sqm
90 90 Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified and as directed 2 Cum
91 91 M&L Brick work with sub class 'B' Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . 2 Cum
92 92 Material and labour, gunniting to existing RCC Chajja, facia, parapet, beams, landings and similar RCC members after removing all loose concrete & preparations of surface, application of derusting chemical such as Dr Fixit Rust Remover or equivalent, welding additional bars/welded steel wire fabric if found necessary, priming reinforcement bars with a coat of zinc primer of coating not less than 40 micron, provision of bonding agent with bonding material like Dr Fixit bonding agent and repair to external RCC structure with slurry light and steel/ply form work and shortcrete concrete of mixed 1:3:1 (one part of cement, three part of coarse sand and one part of 10mm and down aggregate) of minimum 50mm thick incl plastering 5 mm thick in CM mortar 1:3 all as specified in IS 9012-1978 (all priming and bonding epoxy based paint shall be of Dr Fixit epoxy zinc primer or equivalent) etc complete all as specified and directed, as below:- Note(s) : 1. The rates include for necessary formwork and scafolding etc. 2. Reinforcement and welded steel wire fabric will be measured and paid separately work is to be carried out.Upto the height of 4 th storey bldg . 350 Sqm
93 93 M &L Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending etc., and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified. 98 Kg
94 94 Supply only welded steel wire fabric, weight not exc 4kg/sqm, complete all as specified and directed. 1225 Kg
95 95 S&F in repairs vitreous china squating pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, including 100mm cast iron 'P' or 'S' trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete including making good to floor complete all as specified and directed. 5 Each
96 96 S & F in repairs 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed. 5 Each
97 97 S&F powder coated aluminium frame work for doors, windows,partition s etc incl grill for windows for windows etc with one or more rebated section incl jointing cleats for fixing etc complete complete. 50 Kg
98 98 S&F powder coated anodised aluminium door shutters, partition wall, aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubber neoprene packing, handles two Nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and as directed. 10 Sqm
99 99 S&F powder coated anodised aluminium window and ventilator shutters , side hung type without sash bars aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubber packing, aluminium anodised snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1Nos), hinges type B-21 100 mm long(2Nos) suitable handles (1Nos)complete all as specified and as directed. 10 Sqm
100 100 S&F 12 mm thick prelaminated board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to aluminium frame work complete.all as specified and directed by Engineer - in - Charge . 5 Sqm
101 101 S&F 5.5 mm thick selected quality tinted sheet glass and glazing clip in square fixed with PVC/neoprene gasket in aluminium frame work compelte. all as specified and directed by Engineer - in - Charge . 10 Sqm
102 102 S&F double action floor spring hydraulic regulated made up of min 1.25 mm thick aluminium sheet foundation box, main body with stainless steel cover, govering pivets made of brass, other part made up of mild steel heavy duty complete. all as specified and directed by Engineer - in - Charge . 4 Each
103 103 S&F brass six lever dead lock suitable for aluminium doors manufactured by Harrison Locks or Godrej as approved 4 Each
104 104 Dismantling water tanks of capacity exceeding 250 and not exceeding 500 ltrs all as specified and directed by Engineer - in - Charge. 2 Each
105 105 S & F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres 3 layer all as specified and directed by Engineer - in - Charge . 2 Each
106 106 M&L in repair ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball with minimum weight 210 gm screwed for 20mm bore dia iron pipe supplied and fixed in repairs complete all as specified and as directed by Engineer-in-charge. 25 Each
107 107 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition), complete all as specified. 1 Cum
108 108 M&L for providing precast reinforcement cement concrete (1:2:4) type B-1 using 20mm graded aggregate in man holes covers slabs/ Shelves as in slabs supported on walls, beams and columns, in floors, roofs, landings, deck slabs and in shelves and like including necessary form work, complete all as specified and directed by Engr-in-Charge.all as specified. 1 Cum
109 109 Supply only liquid water proofing compound 20 Litre
110 110 E/M Works\nTaking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed. 672 Each
111 111 M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-
112 111.01 One light / fan point controlled by one way switch 150 Per Point
113 111.02 One 5 Amp socket outlet on independent board. 40 Per Point
114 111.03 One 5 Amp socket outlet on same board. 20 Per Point
115 111.04 One bell/buzzer point controlled by one bell push 5 Per Point
116 111.05 One light point controlled by two 2-way switch 2 Per Point
117 112 All as per above item No-111 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed. 50 Per Point
118 113 M&L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including PVC conduit , with mild steel terminal boxes (not less than 1.6 mm thick ) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :-\n
119 113.01 One light / fan point controlled by one way switch 80 Per point
120 113.02 One 5 Amp socket outlet on independent board. 20 Per point
121 113.03 One 5 Amp socket outlet on same board. 20 Per point
122 113.04 One bell/buzzer point controlled by one bell push 2 Per point
123 113.05 One light point controlled by two 2-way switch 1 Per point
124 114 All as per above item no 113 here in befor but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed. 35 Per point
125 115 M & L for replacement of point wiring in existing conduit (PVC/Steel) surface / concealed including existing MS Terminal boxes with 1.5 sqmm FRLS PVC insulated multi stranded copper conductor cable single core 1100 volts grade and one run of 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire and laminated sheet cover 3 mm thick on terminal box duly fixed including taking out old u/s wire of any type and size complete all as specified and as directed for the followings :-
126 115.01 One light / fan point controlled by one way switch 150 Per point
127 115.02 One 5 Amp socket outlet on independent board. 50 Per point
128 115.03 One bell/buzzer point controlled by one bell push 2 Per point
129 116 Ditto all as per above item no 115 but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant ( FRLS ) cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed. 45 Each
130 117 S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and directed by Engineer-in-Charge. 345 Each
131 118 S&F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed by Engineer-in-Charge. 70 Each
132 119 S&F in replacement socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge. 70 Each
133 120 S&F in replacement socket outlet 2-in-1, 3 pin 5 amp and 15 amps all as specified and directed. 70 Each
134 121 S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. Make : 1.Carb tree,2. Roma, 3.Havells 80 Each
135 122 S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed. Make : 1.Carb tree,2. Roma, 3.Havells 60 Each
136 123 S&F in replacement switch 6 amps modular type one one way complete all as directed Make : 1.Carb tree,2. Roma, 3.Havells 185 Each
137 124 S&F in replacement switch 16 amps modular type one one way complete all as directed Make : 1.Carb tree,2. Roma, 3.Havells 60 Each
138 125 S&F in replacement electronic fan regulator Step type complete all as specified and directed.Make-1.Carb tree,2. Hager, 3.Havells 50 Each
139 126 S&F in replacement bell push flush type 5 amp one way ISI Marked complete all as specified and directed. 20 Each
140 127 S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and directed. 20 Each
141 128 S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed. \n 20 Each
142 129 S & F in replacement of Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified as directed 50 Each
143 130 S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed. 150 Each
144 131 S&F in replacement enviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting with pressure die cast aluminium housing ,high efficient LEDs with opal diffuser and IP65 protection all as specified and directed. Make-: 1. Havells cat no- RUGBYNEONFT10WLED860SSYMTOPCOR 2.Halonix cat no HLBH-02-10-CW,Equivalent in Philips, 15 Each
145 132 S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser including all accessaries all as specified and directed. Make:- 1. Havells Cat No LUMILINEPLUSBS20WLED865SPCSS , 2.Halonix cat no HLB-03-20-CW or equivalent in Philips. 180 Each
146 133 S&F in replacement of enviroment friendly indoor decorative 10 Watt LED mirror light polycarbonate Batten with opal diffuser including all accessaries all as specified and directed. Make:- 1. Havells Cat No LUMILINEPLUSBS10WLED865SPCSS or equivalent in Halonix and Philips. 30 Each
147 134 S & F in replacement of sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 2.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.\nNote: (i) New conduit/ casing- caping and accessories shall be measured separately. \n(ii) Two runs of 4.0 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor shall be a unit length. 60 RM
148 135 S & F in replacement of sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.\nNote: (i) New conduit/ casing- caping and accessories shall be measured separately. \n(ii) Two runs of 6.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor shall be a unit length. 80 RM
149 136 S & F in replacement of Regid non-metallic PVC conduit 20 mm (external dia ) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed. 50 RM
150 137 S & F in replacement of Regid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed. 50 Each
151 138 S&F in replacement of sheet metal enclosure double door concealed suitable for distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V complete all as specified and as directed . 5 Each
152 139 S&F in replacement of sheet metal enclosure double door suitable for distribution boards when MCBs to be used having 200Amp rated bus bar 8 ways 240 V complete all as specified and as directed. 10 Each
153 140 S&F in replacement of sheet metal enclosure double door concealed suitable for distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed . 10 Each
154 141 S&F in replacement of single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 25Amp complete all as specified and as directed. 30 Each
155 142 S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'C',breaking capacity 10KA, all as specified. 130 Each
156 143 S&F in replacement MCB SPN 32 to 63 Amps, 240 volts, curve 'C', breaking capacity 10 KA, all as specified. 20 Each
157 144 S&F in replacement of 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 10 Sq mm to be connected to existing MCB box / Main switches complete all as specified as dircted. 80 RM
158 145 S & F In replacement of modular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and as directed. 4 Each
159 146 S & F in replacement of modular Fan Regulator fan step regulator,120W-2 module ISI Marked complete all as specified as as directed. 10 Each
160 147 S & F In replacement of Piano type switch 2 way, 5 Amp,1 module ISI Marked complete all as specified and as directed. 2 Each
161 148 S&F in replacement of modular blanking plate, 1 module ISI Marked complete all as specified and as directed. 15 Each
162 149 S&F in replacement metal flush box 1 module all as specified and directed. 5 Each
163 150 S&F in replacement metal flush box 3 module all as specified and directed. 10 Each
164 151 S&F in replacement metal flush box 6 module all as specified and directed. 15 Each
165 152 S&F in replacement metal flush box 8 module all as specified and directed. 5 Each
166 153 S&F in replacement metal flush box 12 module all as specified and directed. 5 Each
167 154 S&F in replacement for white cover plate with frame, 1 module all as specified and directed. 5 Each
168 155 S&F in replacement for white cover plate with frame, 3 module all as specified and directed. 10 Each
169 156 S&F in replacement for white cover plate with frame, 6 module all as specified and directed. 15 Each
170 157 S&F in replacement for white cover plate with frame, 8 module all as specified and directed. 5 Each
171 158 S&F in replacement for white cover plate with frame, 12 module all as specified and directed. 5 Each
172 159 S&F in replacement of Hylem sheet 12"x15" complete all as specified and as directed. 5 Each
173 160 S&F in replacement of Hylem sheet 8"x5" complete all as specified and as directed. 15 Each
174 161 S&F in replacement of Hylem sheet 5"x5" complete all as specified and as directed. 5 Each
175 162 S&F in replacement of MS Box 10"x12"x3" complete all as specified and as directed. 5 Each
176 163 S&F in replacement of MS Box 7"x4"x3" complete all as specified and as directed. 10 Each
177 164 Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed. 5 Each
178 165 M & L for replacement of street light bracket made out of 40 mm dia light grade GI pipe bend to shape not less than 1.8 mtr length along with 02 Nos fixing clamps properly shaped and fabricated out of 50 x 5 mm thick MS flat nut & bolts duly painted with 2 coats of aluminium paint over 1 coat of red oxide complete all as specified and as directed. 10 Each
179 166 S&F in replacement new generation energy saving and enviroment friendly high efficient high power 45 Watt LED street light made up of pressure die cast aluminium housing and enclosed with toughened glass with IP66 protecton and impact resistance of IK07 all as specified and directed.MAKE-1.Havells cat no ENDURAPEARLNEOSL45WLED757PASYTOPC 2.Crompton 3.Bajaj 10 Each
180 167 Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 2 core complete all as specified and directed. 80 RM
181 168 S&F in replacement enviroment friendly 35 Watt LED Post top lantern with pressure die cast aluminium spigot IP65 protection with high power COB LED as light source complete all as specified and directed. Make-:1.Havells cat no ENDURASPRING6PT35WLED740PSYMTOTG or equivalent in Halonix Philips/Bajaj 4 Each
182 169 Supply and fix in replacement double door TPN DBs four way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and directed . 5 Each
183 170 S & F in replacement with MCB TPN 32 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and directed . 5 Each
184 171 S & F in replacement with MCB TPN 50 to 63 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and directed . 5 Each
185 172 S & F in replacement with MCB TPN 100 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and directed. 5 Each
186 173 Taking down defective board / fittings / fixtures including identifying and rectifying the defective parts by providing new fittings and fixtures pertaining to internal electrification of any type and nature of married accns such as rectification of faulty electric circuits, tightening of loose wiring with conduits & repair of defective switch, sockets , Ceiling rose , Capacitor , light fittings etc of any type and any rating and fix repair or new fixture complete all as directed at site .\nNOTE -:(1) All the materials / stores required for rectification of complaints shall be measured and paid under relevent item. (2) Complaints where compleate replacement of circuit / point wiring required shall be measured under relevent item. 3) Cost of minor stores such as screws,clamps,insulation tapes,nuts / bolts, lugs / thimble / hole fast / fastener etc shall be deemed included in the above quoted items. 40 Each Job
187 174 Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 2 core complete all as specified and directed 55 RM
188 175 S&F in replacement of enviroment friendly indoor decorative type city 2 light with 9 Watt retrofit LED lamp B22 base made up of polycarbonate including all accessaries all as specified and directed. Make:- 1. Havells Cat No LHDL03160099, equivalent in Philips and Halonix. 10 Each
189 176 S&F in replacement of enviroment friendly indoor decorative type wall mounting ,brushed nickel finish fixture with opal glass diffuser with 9 Watt retrofit LED lamp B22 base made up of polycarbonate including all accessaries all as specified and directed. Make:- 1. Havells Cat No LHFOAJE1TZ1I060, equivalent in Philips and Halonix. 10 Each
190 177 S&F in replacement of enviroment friendly indoor decorative type wall mounting ,brushed nickel finish fixture with opal glass diffuser with 9 Watt retrofit LED lamp B22 base made up of polycarbonate including all accessaries all as specified and directed. Make:- 1. Havells Cat No LHFOAJE1TN1I060, equivalent in Philips and Halonix. 10 Each
191 178 S & F in replacement enviroment friendly recess/pendent mounting LED flat panel 2'x2' fabricated CRCA sheet steel housing cool white with high efficient LEDs & glare free opal diffuser (34 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V including all accessaries all as specified and directed. Make-:1.Havells cat part No-PLUTONE2X2PLR34WLED840S, equivalent in philips,Halonix 10 Each
192 179 Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 25 Sqmm nominal cross section 3.5 core complete all as specified and directed 59 RM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail