Provision Of Flood Light At The Backside , Replacement Of Defective Power Boards / Exhaust Fan/ Light Circuits And Repairing Of Various Defective T-5 Fittings Installed In Various Rooms Of Dream Building , University Of Delhi, North Campus-Delhi

Delhi University has published Provision Of Flood Light At The Backside , Replacement Of Defective Power Boards / Exhaust Fan/ Light Circuits And Repairing Of Various Defective T-5 Fittings Installed In Various Rooms Of Dream Building , University Of Delhi. Submission Date for this Tender is 07-10-2020. Halogen Light Tenders in North Campus Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

25475543
Provision Of Flood Light At The Backside , Replacement Of Defective Power Boards / Exhaust Fan/ Light Circuits And Repairing Of Various Defective T-5 Fittings Installed In Various Rooms Of Dream Building , University Of Delhi
Open Tender
Indian
Delhi
North Campus
07-10-2020

Tender Details

Provision Of Flood Light At The Backside , Replacement Of Defective Power Boards / Exhaust Fan / Light Circuits And Repairing Of Various Defective T-5 Fittings Installed In Various Rooms Of Dream Building , University Of Delhi

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
INR 1.93 Lakhs /-

BOQ Items

Name of Work: Provision of flood light at the backside, replacement of defective power boards / exhaust fan/ light circuits and repairing of various defective T-5 fittings installed in various rooms of Dream Building, University of Delhi
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supplying/ installation/ testing and commissioning of 120 watts LED street light fitting complete with all accessories i/c having pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and Impact resistance of IK07 Build In SPD i/c making connection as required (Philips/ Havells/ Crompton) BI01010001010000000000000515BI0100001112 2 Nos.
2 2 Supplying/ laying of one number PVC insulated and PVC sheathed/ XLPE aluminium cond power cable of 1.1 KV grade of following size direct in ground i/c excavation, sand cushioning, protective covering and refilling the trench etc. as required at site. 2x16 sqmm BI01010001010000000000000515BI0100001113 100 metre
3 3 Supplying and fixing of PVC 8"x10" pole box complete with all accessories having suitable clamps, 6 amps TPN strip, brass nut bolts i/c having 1 No. of 10 amps SP MCB and making connection etc. as required (Syntex make) BI01010001010000000000000515BI0100001114 4 Nos.
4 4 Supplying and fixing of following accessories in the existing tubelight fitting for repairing and making connection as required. BI01010001010000000000000515BI0100001115
5 4.01 28 watts Choke BI01010001010000000000000515BI0100001116 50 Nos.
6 4.02 28 watts tubelight BI01010001010000000000000515BI0100001117 100 Nos.
7 5 Supplying and fixing of 12" dia. Heavy duty exhaust fan complete with all accessories i/c making connection etc. as required. BI01010001010000000000000515BI0100001118 6 Nos.
8 6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001119
9 6.01 15 amps switch BI01010001010000000000000515BI0100001120 40 Nos.
10 6.02 15 amps socket BI01010001010000000000000515BI0100001121 40 Nos.
11 7 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001122 10 Nos.
12 8 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) BI01010001010000000000000515BI0100001123 8 Nos.
13 9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. BI01010001010000000000000515BI0100001124
14 9.01 3c x 4 sq.mm BI01010001010000000000000515BI0100001125 40 metre
15 9.02 3c x 1.5 sq.mm BI01010001010000000000000515BI0100001126 100 metre
16 10 S/F of snap-on DLP trunking of 105mm X 50mm with suitable cover on the existing wall/ surface i/c having all the accessories such as Flat angle, end caps, intenal/ external angle etc. as required at site. BI01010001010000000000000515BI0100001127 20 metre
17 11 Supplying and fixng of AC box having suitable 3 Module G.I. box with modular plate having 1 No. of 25 amps socket and 1 No. of Tinny Trip G Series MCB i/c having plug top and making connection as required. BI01010001010000000000000515BI0100001128 2 Nos.
18 12 Dismantling the existing fitting and depositing the same at Engineering Store. BI01010001010000000000000515BI0100001129 1 Job