Renovation Work At Sub-Registrar Office Koothattukulam
BOQ
| Work Name:Renovation work at Sub-Registrar Office Koothattukulam. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Repairs and maintenance | BI01010001010000000000000515BI0100001113 | ||
| 2 | 1.01 | 14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) | BI01010001010000000000000515BI0100001114 | 5.8 | sqm |
| 3 | 1.02 | 14.43 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | BI01010001010000000000000515BI0100001115 | 1171.85 | sqm |
| 4 | 1.03 | 14.66.1 : Finish walls with Acryllic Smooth exterior paint of required shade:Old work ( Two or more coats applied @ 1.67 ltr/10 sqm) on existing cement paint surface | BI01010001010000000000000515BI0100001116 | 603.019 | sqm |
| 5 | 1.04 | 14.53.1 : Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work | BI01010001010000000000000515BI0100001117 | 723.445 | sqm |
| 6 | 1.05 | 14.54.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work | BI01010001010000000000000515BI0100001118 | 127.957 | sqm |
| 7 | 1.06 | od38227/2019_2020 : Engaging second class carpenter for patch work of doors and windows | BI01010001010000000000000515BI0100001119 | 2 | Day |
| 8 | 1.07 | 12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001120 | 415.671 | sqm |
| 9 | 1.08 | 50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | BI01010001010000000000000515BI0100001121 | 1831.24 | kg |
| 10 | 1.09 | 50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | BI01010001010000000000000515BI0100001122 | 812.626 | kg |
| 11 | 1.1 | od39595/2019_2020 : Engaging man mazdoor for cleaning old celing | BI01010001010000000000000515BI0100001123 | 2 | Day |
| 12 | 1.11 | od30032/2020_2021 : Providing and fixing 200 mm wide, semi circular plain PVC gutter with iron brackets 8''x4 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.\r(As per invoice No. A207 dated 09.06.2020) | BI01010001010000000000000515BI0100001124 | 76.4 | metre |
| 13 | 1.12 | 14.75A : Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity\nat all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank\nand cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm\nper litre capacity of tank including marking the date of cleaning on the side of tank body\nwith the help of stencil and paint and disposing of malba all complete as per direction\nof Engineer-in-Charge. (The old date already written on tank should be removed with\npaint remover or black paint and if date is not written with the stencil or old date is not\nremoved deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings\nor ball cock is damaged that is to be repaired by contractor at his own cost and nothing\nextra will be paid on this account)Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacityat all heights with coconut brushes, duster etc., removal of silt, rubbish from the tankand cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gmper litre capacity of tank including marking the date of cleaning on the side of tank bodywith the help of stencil and paint and disposing of malba all complete as per directionof Engineer-in-Charge. (The old date already written on tank should be removed withpaint remover or black paint and if date is not written with the stencil or old date is notremoved deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittingsor ball cock is damaged that is to be repaired by contractor at his own cost and nothingextra will be paid on this account) | BI01010001010000000000000515BI0100001125 | 1000 | Litre |
| 14 | 1.13 | 50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | BI01010001010000000000000515BI0100001126 | 3.6 | cum |
| 15 | 1.14 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001127 | 84.3 | sqm |
AI Tender Summary
Tender Timeline
Sep 16, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedSep 25, 2020