| 1 | 1 | Material and labour for taking out Centrifugal Pump of capacity 120 HP, transportation of same from site to workshop and back, dismantling of cable / pipe connection and reinstallation of pump set after repair on the existing foundation and making electrical connections complete all as specified and directed. Note : All spares parts required will be measured and paid for separately | | 3 | Each \nJob |
|---|
| 2 | 1.01 | Supply only MS tyre coupling suitable size 120 HP Centrifugal pump set including making necessary machining work like, boring, key way and key etc., work required at site in the delivery pipe lines | | 3 | Each |
|---|
| 3 | 1.02 | Supply only Ball Bearing No.6313 Make : SKF | | 6 | Each |
|---|
| 4 | 1.03 | Supply only Ball Bearing No.6307 Make : SKF | | 6 | Each |
|---|
| 5 | 1.04 | Supply only CI Bearing Housing | | 6 | Each |
|---|
| 6 | 1.05 | Supply only Water Seal 50mm x 68mm x 10mm | | 3 | Each |
|---|
| 7 | 1.06 | Supply only Packing Sheet | | 3 | Each \nSet |
|---|
| 8 | 1.07 | Supply only 'O' Ring Set | | 3 | Each \nSet |
|---|
| 9 | 1.08 | Supply only Pump Shaft SS AISI-410 | | 3 | Each |
|---|
| 10 | 1.09 | Supply only SS Nut Bolt & Washer of 10mm dia | | 18 | Each |
|---|
| 11 | 1.1 | Supply only Grease | | 8 | Kilogram |
|---|
| 12 | 1.11 | Supply only Graphite Gland Dori | | 8 | Kilogram |
|---|
| 13 | 2 | Material and labour for taking out Centrifugal Pump of capacity 15 HP, transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of pump set after repair on the existing foundation and making electrical connections complete all as specified and directed. Note : All spares parts required shall be measured and paid for separately | | 1 | Each \nJob |
|---|
| 14 | 2.01 | Supply only Ball Bearing No.6309 Make : SKF | | 2 | Each |
|---|
| 15 | 2.02 | Supply only Ball Bearing No.6306 Make : SKF | | 2 | Each |
|---|
| 16 | 2.03 | Supply only Mechanical Seal Carbon TC / TC / Viton 40 mm | | 1 | Each |
|---|
| 17 | 2.04 | Supply only Mechanical Seal TC / TC / Viton 40 mm | | 1 | Each |
|---|
| 18 | 2.05 | Supply only Rubber 'O' Ring | | 1 | Each |
|---|
| 19 | 2.06 | Supply only Neck Ring | | 1 | Each |
|---|
| 20 | 2.07 | Supply only Impellor Lock Nuts SS | | 1 | Each |
|---|
| 21 | 2.08 | Supply only SS Studs 80 mm x 60 mm | | 12 | Each |
|---|
| 22 | 2.09 | Supply only SS Nuts 80 mm | | 12 | Each |
|---|
| 23 | 2.1 | Supply only SS Nuts 12 mm | | 12 | Each |
|---|
| 24 | 2.11 | Supply only SS Nuts 16 mm | | 12 | Each |
|---|
| 25 | 2.12 | Supply only Packing sheet | | 1 | Each |
|---|
| 26 | 2.13 | Supply only Mobile Oil - 5 Litre | | 1 | Each\nPack \nof\n05 Litres |
|---|
| 27 | 2.14 | Supply only Circlips Clamp | | 1 | Each |
|---|
| 28 | 3 | Material and labour for taking out Motor Set of capacity 120 HP from position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections complete all as specified and directed. \nNote : All spares parts required shall be measured and paid for separately | | 3 | Each |
|---|
| 29 | 3.01 | Material and labour for rewinding of damaged / burnt motor of capacity 120 HP any type by using enamelled copper wire of superior quality of existing grade and same Nos. of turns including varnishing ‘F’ class insulation and drying in heat chamber / Oven including all other material / fittings and testing on completion, complete all as specified and directed. | | 282 | Kilogram |
|---|
| 30 | 3.02 | Ball Bearing for 120 HP capacity motor front side | | 6 | Each |
|---|
| 31 | 3.03 | Ball Bearing for 120 HP capacity motor back side | | 6 | Each |
|---|
| 32 | 3.04 | Mechanical Seal for 120 HP capacity motor | | 3 | Each |
|---|
| 33 | 3.05 | Rubber washer Kit for 120 HP capacity motor | | 3 | Each |
|---|
| 34 | 3.06 | Bush cover for 120 HP capacity motor | | 3 | Each |
|---|
| 35 | 3.07 | Packing sheet for 120 HP capacity motor | | 3 | Each |
|---|
| 36 | 3.08 | Circlips Clamp for 120 HP capacity motor | | 3 | Each |
|---|
| 37 | 4 | Material and labour for taking out Motor Set of capacity 15 HP from position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections complete all as specified and directed. \nNote : All spares parts required shall be measured and paid for separately | | 1 | Each \nJob |
|---|
| 38 | 4.01 | Material and labour for rewinding of damaged/burnt motor of capacity 15 HP any type by using enamelled copper wire of superior quality of existing grade and same Nos. of turns including varnishing ‘F’ class insulation and drying in heat chamber / oven including all other material / fittings and testing on completion, complete all as specified & directed. | | 35 | Kilogram |
|---|
| 39 | 4.02 | Ball Bearing for 15 HP capacity motor front side | | 2 | Each |
|---|
| 40 | 4.03 | Ball Bearing for 15 HP capacity motor back side | | 2 | Each |
|---|
| 41 | 4.04 | Mechanical Seal for 15 HP capacity motor | | 1 | Each |
|---|
| 42 | 4.05 | Rubber washer for 15 HP capacity motor | | 1 | Each |
|---|
| 43 | 4.06 | Bush cover for 15 HP capacity motor | | 1 | Each |
|---|
| 44 | 4.07 | Packing sheet for 15 HP capacity motor | | 1 | Each |
|---|
| 45 | 4.08 | Circlips Clamp for 15 HP capacity motor | | 1 | Each |
|---|
| 46 | 5 | Material and Labour for disconnecting of 20/15 HP Submersible Pump Set motor kit from inside the Water Supply Sump from the delivery pipe for repair / rewinding, lifting, transportation to approved workshop for repair / rewinding with super enamalled copper winding wire of suitable size, insulation material i.e PVC copper cable lead, glass fibre sleeves, cotton tape, insulation paper, varnish and bearing grease etc., & reassembling of motor after rewinding and fixing the same at its original position with and including necessary nuts, bolts, washers etc., required at site of work, complete all as specified & directed. | | 3 | Each \nJob |
|---|
| 47 | 6 | Submersible flat cable PVC insulated and PVC sheathed LT 1100 volts grade with copper conductor of size 10 Sqmm 3 Core, complete all as specified and directed.\nMake : Havells / Finolex / Polycab / Plaza / Asian | | 300 | Running Metre |
|---|
| 48 | 7 | PVC insulated and PVC sheathed LT cable 1100 volt grade with copper conductor of size 35 Sqmm single core complete all as specified and as directed. \nMake : Polycab / Havells / KEI / RPG / Finolex / Universal | | 100 | Running Metre |
|---|
| 49 | 8 | Supply only Solid Ferric Alum suitable for treatment of Raw water all as specified and directed by Engineer-in-Charge Make : Arihant Chemical/Shri Krishna Enterprises/Actuate Chemical Industries/Ama Speciality India | | 2200 | Kilogram |
|---|
| 50 | 9 | Supply only Poly Aluminium Chloride Powder AC / 1005 suitable for treatment of raw water, complete all as specified & directed. \nMake : Acuro Organics Limited / Chemtex Speciality Limited / Akshar Exim Company Pvt Ltd | | 2200 | Kilogram |
|---|
| 51 | 10 | Supply only Calcium Hypochlorite (Bleaching Powder) Each bag 25 Kg pkt for water treatment all as specified and directed by Engineer-in-Charge Make : Suvidhi Industries/ Arihant Chemical/Choice Organochem / Ama Speciality India/ AB Enterprises/Banke Behari Chemicals | | 1800 | Kilogram |
|---|
| 52 | 11 | Star Delta Starter automatic controlled, Three Phase, 440 volts including push button for start and stop suitable for 120 HP motor having accessories such as contactor, relay, start and stop button including making necessary connections, complete including taking down old unserviceable Star Delta Starter all as specified and directed. \nMake : Legrand / Siemens / Havells / BCH. | | 2 | Each Job |
|---|
| 53 | 12 | DOL starter suitable for upto 20/15 HP capacity electric motor, complete including taking down old unserviceable Starter all as specified and as directed.\nMake : L&T / Havells / Legrand / ABB | | 1 | Each |
|---|
| 54 | 13 | Stainless Steel (SS) Sluice Valve class PN-1, PD short body conforming to IS:14846-2000, heavy duty, both ends flanged with stainless steel spindle & check nut, operating wheel, all nuts, bolts, washers, gaskets etc. of following description, including dismantling of old unserviceable Sluice Valve, complete all as specified & directed. | | | |
|---|
| 55 | 13.01 | (a) 200 mm bore | | 2 | Each |
|---|
| 56 | 13.02 | (b) 150 mm bore | | 2 | Each |
|---|
| 57 | 14 | Stainless Steel (SS) Non Return Valve without by-pass arrangement, swing type, confirming to IS:5312, flanged ends, all nuts, bolts, washers, gaskets etc. of following description, including dismantling of old unserviceable NRV, complete all as specified and directed. | | | |
|---|
| 58 | 14.01 | (a) 300 mm bore | | 1 | Each |
|---|
| 59 | 14.02 | (b) 200 mm bore | | 2 | Each |
|---|
| 60 | 14.03 | (c) 150 mm bore | | 2 | Each |
|---|
| 61 | 15 | Cast Iron Foot Valve flanged type 200 mm bore with drilled flanged end all as per IS : 4038 with Cast Iron Strainer including dismantling of old unserviceable foot valve complete all as specified and as directed. | | 2 | Each |
|---|
| 62 | 16 | Cast Iron Foot Valve flanged type 100 mm bore with drilled flanged end all as per IS : 4038 with Cast Iron Strainer including dismantling of old unserviceable foot valve complete all as specified and as directed. | | 1 | Each |
|---|
| 63 | 17 | Cast Iron Air valves with air outlets, conforming to IS-14845 of size 50mm bore and fixing up in cast iron water supply mains of size 50 mm dia including dismantling of old unserviceable air release valve complete all as specified and directed | | 5 | Each |
|---|
| 64 | 18 | Cast Iron Air valves with air outlets, conforming to IS-14845 of size 80mm bore and fixing up in cast iron water supply mains of size 80 mm dia including dismantling of old unserviceable air release valve complete all as specified and directed. | | 3 | Each |
|---|
| 65 | 19 | Cast Iron Sluice Valve class PN-1.6 PN short body conforming to IS:14846-2000, heavy duty, both ends flanged with stainless steel spindle & check nut, CI operating wheel, all nuts, bolts, washers, gaskets etc. of the following description, including dismantling of old unserviceable Sluice Valve, complete all as specified & directed. | | | |
|---|
| 66 | 19.01 | (a) 400 mm bore | | 1 | Each |
|---|
| 67 | 19.02 | (b) 200 mm bore | | 3 | Each |
|---|
| 68 | 19.03 | (c) 150 mm bore | | 3 | Each |
|---|
| 69 | 19.04 | (d) 100 mm bore | | 2 | Each |
|---|
| 70 | 19.05 | (e) 150 mm bore | | 1 | Each |
|---|
| 71 | 20 | MCCB 500 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) including taking down old unserviceable MCCB complete all as specified and as directed. | | 1 | Each |
|---|
| 72 | 21 | MCCB 250 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) including taking down old unserviceable MCCB complete all as specified and as directed. | | 1 | Each |
|---|
| 73 | 22 | MCCB 200 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) including taking down old unserviceable MCCB complete all as specified and as directed. | | 1 | Each |
|---|
| 74 | 23 | MCCB 160 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) including taking down old unserviceable MCCB complete all as specified and as directed. | | 1 | Each |
|---|
| 75 | 24 | MCCB 100 Amps, breaking capacity 25 KA, TP, 415V (adjustable thermal and magnetic release) including taking down old unserviceable MCCB complete all as specified and as directed. | | 1 | Each |
|---|
| 76 | 25 | MCCB 63 Amps, breaking capacity 25 KA, TP, 415V (adjustable thermal and magnetic release) including taking down old unserviceable MCCB complete all as specified and as directed. | | 1 | Each |
|---|
| 77 | 26 | Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 Volt of capacity 25 KVAR complete all as specified and as directed. | | 1 | Each |
|---|
| 78 | 27 | Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 Volt of capacity 20 KVAR complete all as specified and as directed. | | 1 | Each |
|---|
| 79 | 28 | Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 volt of capacity 15 KVAR complete all as specified and as directed. | | 1 | Each |
|---|
| 80 | 29 | Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 volt of capacity 10 KVAR complete all as specified and as directed. | | 1 | Each |
|---|
| 81 | 30 | Power Factor improvement capacitor mixed dielectric oil filled type, Three Phase, 415 volt of capacity 5 KVAR complete all as specified and as directed. | | 1 | Each |
|---|
| 82 | 31 | ON LOAD Change Over Switch 415 volt in sheet metal enclosure Four Pole of capacity 315 Amps complete all as specified and directed | | 1 | Each |
|---|
| 83 | 32 | Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed. | | 8 | Each |
|---|
| 84 | 33 | Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion. | | 4 | Each\nJob |
|---|
| 85 | 34 | Supplying, installing, testing and commissioning of LT indoor type panel board factory fabricated cubical kiosk type whether,dust, vermin proof, CPRI approved with locking arrangement and made out of MS sheet 3.15 mm thick duly painted with one coat of red oxide paint and two coat of synthetic enamel paint , powder coated mounted on platform The panel shoule be suitable load of 20/15 HP(Kw) Non clog submersible pumping set, pump model ETERNA 15000 CW 4P all as specified with the following accessories:-\n(i) Electronic Star-Delta starter complete\n(ii) Digital multifunction meter displaying voltage, current and power factor\n(iii) Unbalance voltage protection device\n(iv) Multi functioning motor protection relay along with all accessories and fault indication top provide protection against over temperature, over current, over voltage, under current, under voltage, earth fault complete fixed on panel with all electric connections. | | 2 | Each\nJob |
|---|
| 86 | 35 | Supply, laying, jointing and testing Mild steel ERW pipes having minimum 5.4 mm wall thickness confirming to IS : 1239-2004 amended upto date in any length of following description, complete all as pecified and as directed. \nMake : TATA / Jindal / Prakash / Swastik | | | |
|---|
| 87 | 35.01 | (a) 400 mm bore | | 9 | Running Meter |
|---|
| 88 | 35.02 | (b) 200 mm bore | | 12 | Running Meter |
|---|
| 89 | 35.03 | (c) 150 mm bore | | 12 | Running Meter |
|---|
| 90 | 36 | Excavating in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out, complete all as specified and as directed. | | 3.5 | Cubic Metre |
|---|
| 91 | 37 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. | | 3 | Cubic Metre |
|---|
| 92 | 38 | Removing excavated soils not exceeding 50 metres and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed. | | 0.5 | Cubic Metre |
|---|
| 93 | 39 | Supply and fixing Gun metal globe / gate valve ISI Marked with and including jointing meterial and taking out old unserviceable valves complete all as specified and directed of following sizes :- \nMake : Advance / Bir / Leader / Sant | | | |
|---|
| 94 | 39.01 | (a) 50 mm bore | | 6 | Each |
|---|
| 95 | 39.02 | (b) 40 mm bore | | 6 | Each |
|---|
| 96 | 39.03 | (c) 25 mm bore | | 6 | Each |
|---|
| 97 | 39.04 | (d) 20 mm bore | | 7 | Each |
|---|
| 98 | 39.05 | (e) 15 mm bore | | 6 | Each |
|---|