| 1 | 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS 20B and Sand, silt or other loose soil, wet sand, silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed, cleaning and levelling the site etc., complete - Footings | BI01010001010000000000000515BI0100001113 | 1563 | M3 |
|---|
| 2 | 2 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS 20B and Sand, silt or other loose soil, wet sand, silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed, cleaning and levelling the site etc., complete - Open Earthwork | BI01010001010000000000000515BI0100001114 | 231 | M3 |
|---|
| 3 | 3 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B in ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering, and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed depositing the surplus excavated soil with in the compound in places shown by the departmental officers with intial lead and lifts and cleaning and levelling the site etc.,complete - Open Earth work excavations For Drain | BI01010001010000000000000515BI0100001115 | 24 | M3 |
|---|
| 4 | 4 | Plain Cement concrete 1:4:8 (one cement, four sand, eight aggregate) using 40mm gauge hand broken granite stone jelly for foundation including dewatering if found necessary and laid in layers of not more than 15 cm thick and compacted,etc., complete complying with standard specfication. | BI01010001010000000000000515BI0100001116 | 152 | M3 |
|---|
| 5 | 5 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plinth Beam | BI01010001010000000000000515BI0100001117 | 1136 | M2 |
|---|
| 6 | 6 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. | BI01010001010000000000000515BI0100001117 | 990 | M2 |
|---|
| 7 | 7 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. - For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. | BI01010001010000000000000515BI0100001117 | 1487 | M2 |
|---|
| 8 | 8 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Drain | BI01010001010000000000000515BI0100001117 | 192 | M2 |
|---|
| 9 | 9 | Plain Cement Concrete 1:3:6 Mix (one part cement, three part sand and six part of aggrigate) using 20 mm size ISS HBG metal from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing. Laying and curing etc., complete as per TNDSS NO: 28 & VI (S2) VI (S5A) VII standard specifications as directed by Engineer incharge. | BI01010001010000000000000515BI0100001117 | 30 | M3 |
|---|
| 10 | 10 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials) - Upto Basement | BI01010001010000000000000515BI0100001117 | 293 | M3 |
|---|
| 11 | 11 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials) - Ground Floor | BI01010001010000000000000515BI0100001117 | 200 | M3 |
|---|
| 12 | 12 | Supply and fabrication of steel required for all RCC items of works involved in the schedule, cost of steel at site fabrication, labour charges for cleaning the rods straightening, cutting, bending, tying grills, including overlapping to the required length whenever necessary and placing the reinforcement in position as as per design given and specified in the drawings, including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc complete as per standard specification | BI01010001010000000000000515BI0100001117 | 50 | Mt |
|---|
| 13 | 13 | Brick work in CM 1:5 (one cement & Five sand) using II class ground moulded bricks of size 9\"X43/8\"X 23/4\" standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost)- Upto Basement | BI01010001010000000000000515BI0100001117 | 118 | M3 |
|---|
| 14 | 14 | Brick work in CM 1:5 (one cement & Five sand) using II class ground moulded bricks of size 9\"X43/8\"X 23/4\" standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost) - Ground Floor | BI01010001010000000000000515BI0100001117 | 17 | M3 |
|---|
| 15 | 15 | Brick Partition walls in CM 1:3 (one cement & three sand) using II class ground moulded bricks of size 9\"X43/8\"X23/4\" using hoop iron reinforcement 2 Nos of 6mm dia M.S.rod at every three alternate layers and the cost shall inclusive of iron reinforcement, Brick work etc, complete as per standard specification - Ground Floor | BI01010001010000000000000515BI0100001117 | 415 | M2 |
|---|
| 16 | 16 | Collection supply and filling of well gravel filling approved quarry including cost and Conveyance of all materials to site and all labour charges for filling etc., Complete. | BI01010001010000000000000515BI0100001117 | 339 | M3 |
|---|
| 17 | 17 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. | BI01010001010000000000000515BI0100001117 | 700 | Kg |
|---|
| 18 | 18 | Special ceiling plastering in all floors and finishing the exposed surface of RCC items of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three sand) 10mm thick including hacking the surfaces and providing cement mortar nosing, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers. | BI01010001010000000000000515BI0100001117 | 1877 | M2 |
|---|
| 19 | 19 | Plastering with cement mortar 1:5 (One cement and five sand) 12mm thick in all floors including cost and conveyance of all materials to site etc,complete as per standard specifications (S.I.306) | BI01010001010000000000000515BI0100001117 | 1756 | M2 |
|---|
| 20 | 20 | Painting two coats of newly plastered wall surface with ready mixed exterior emulsion paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required etc., complete complying with standard specification. | BI01010001010000000000000515BI0100001117 | 3633 | M2 |
|---|
| 21 | 21 | Paving the floor with design Antiskid ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement etc, complete as per standard specification. | BI01010001010000000000000515BI0100001117 | 738 | M2 |
|---|
| 22 | 22 | Dadooing the walls with glazed tiles of 30 c.m x 20 c.m 6mm size laid in cement mortor 1:2 mix 10mm thick and pointing with 0.40 kg white cement per m2 etc. | BI01010001010000000000000515BI0100001117 | 108 | M2 |
|---|
| 23 | 23 | Supplying and fixing in Position of Indian Oriya pan type water closet with “P’’ or “S’’ trap to set in brick jelly concrete 1:4:8 Mix concrete 10 cm thick using 20mm brick jelly and top finished with c.m. 1:3 mix 20mm thick without any leakage etc. complete. | BI01010001010000000000000515BI0100001117 | 10 | No |
|---|
| 24 | 24 | Supplying and fixing in position colour glazed EUROPEAN WATER CLOSET with 'P' or 'S' trap and double flapped seat cover, 10.00 litres capacity P.V.C. low level FLUSHING TANK including all internal fittings fixed on C.I. brackets, 12mm PVC or brass nipple, chromium plated brown headed stopcock, 12mm nylon connection with necessary teakwood plugs, clamps, screws to the portion coming with walls and floors, including dismantling masonry and redoing the same to the original condition. | BI01010001010000000000000515BI0100001117 | 2 | No |
|---|
| 25 | 25 | Fabricating, supplying and fixing in positon of SOLID PVC DOORS with frames of different sizes as per the specifications given below: PVC door frames made out of best quality PVC extruded section of 40mm * 58 mm * 2.50 mm +/- 0.3 mm thick, having multichamber cross section and duly reinforced with steel to be mitre cut at the corners and welded including providing tie rod at the bottom and necessary weather seal etc., and PVC door shutters made out of extruded plastic section of 60 mm * 24 mm size in the configruation of an \"A\" section for shutter frames and multi-chamber hollow plastic section of 200 mm *200 mm*1 mm (average thickness) with tongue and groove section for panels etc., with necessary holdfasts, rubber beedings, furniture fittings, locking arrangements etc., complete including dimantling the masnery, making chippings, holes in the RCC column, beam etc., wherever necessary with power drill to the extent required and redoing the same to the original condition after fixing etc., complete as per specifications and as directed by the departmental officers. | BI01010001010000000000000515BI0100001117 | 22.68 | M2 |
|---|
| 26 | 26 | Providing and laying, spreading and compacting graded stone aggregate to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications. | BI01010001010000000000000515BI0100001117 | 228 | M3 |
|---|
| 27 | 27 | Supplying and laying Rubberised interlocking Paver block M40 grade Providing and laying of 83mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40 N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dustcushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, Stone Dust cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. | BI01010001010000000000000515BI0100001117 | 1515 | M2 |
|---|
| 28 | 28 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification | BI01010001010000000000000515BI0100001117 | 3000 | Kg |
|---|
| 29 | 29 | Supply and Fixing of Polycarbonate Sheet 6 mm Thick Including 15 cm Lapping roof With Necessary J bolt and Nut With Bitumen Washer and Screws if wooden baterns including cost and conveyance of all materials and all labour charges etc.,Complete complying with standard Specifications. | BI01010001010000000000000515BI0100001117 | 527 | M2 |
|---|
| 30 | 30 | Finishing the top of roof with one course of machine pressed tiles 23 C.m x 23 C.m x 2 C.m size using cement mortor 1:3 mix mixed with 2% by weight of Crude Oil and pointing with Cement Mortor 1:3 mix Cost of all materials and labour charges and brick jelly concrete etc., complete as per standard specifications. | BI01010001010000000000000515BI0100001117 | 960 | M2 |
|---|
| 31 | 31 | Wiring with2x1.5sq.mm(22/0.3)PVCinsulated SCunsheathed copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with 150x100x113mm TW switchbox for 5A 3 pin non interlocking Wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC plug point(SD 36 ) | BI01010001010000000000000515BI0100001118 | 150 | No's |
|---|