Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #25428746

Kiifb - Construction Of New Building To Ghss Munnoorcode In Pookkottukavu Grama Panchayath .

Issued by Boards / Undertakings / PSU · POOKKOTTUKAVU GRAMA PANCHAYATH., Kerala
Tender Value
79.21 Lakhs
Estimated cost
Bid Submission
25 Sep 2020
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
POOKKOTTUKAVU GRAMA PANCHAYATH. → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Kiifb - Construction Of New Building To Ghss Munnoorcode In Pookkottukavu Grama Panchayath .

BOQ

Work Name:KIIFB - Construction of New Building to GHSS Munnurcode in Pookkottukavu GP, Palakkad Dist.(School Code:20033)
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11EARTH WORKBI01010001010000000000000515BI0100001113
21.0012.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI0100001114278.642cum
31.0022.35.3.1 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentrationBI01010001010000000000000515BI0100001115207.481sqm
41.0032.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.BI01010001010000000000000515BI0100001116254.538cum
52STONE MASONRYBI01010001010000000000000515BI0100001117
62.0017.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)BI01010001010000000000000515BI010000111813.73cum
73PCCBI01010001010000000000000515BI0100001119
83.0014.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI010000112036.023cum
94CENTERING SHUTTERINGBI01010001010000000000000515BI0100001121
104.0015.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI0100001122160.56sqm
114.0025.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantileversBI01010001010000000000000515BI0100001123428.287sqm
124.0035.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and StrutsBI01010001010000000000000515BI0100001124359.4sqm
134.0045.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platformBI01010001010000000000000515BI0100001125480.226sqm
144.0055.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)BI01010001010000000000000515BI010000112659.424sqm
155REINFORCED CEMENT CONCRETEBI01010001010000000000000515BI0100001127
165.0015.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal sizeBI01010001010000000000000515BI010000112861.498cum
175.0025.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000112930.798cum
185.0035.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).BI01010001010000000000000515BI0100001130103.032cum
196REINFORCEMENT FOR RCCBI01010001010000000000000515BI0100001131
206.0015.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI010000113221560kilogram
217BRICK WORKBI01010001010000000000000515BI0100001133
227.00150.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc completeBI01010001010000000000000515BI0100001134118.202cum
237.00250.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc completeBI01010001010000000000000515BI010000113517.748cum
248STEEL WORKBI01010001010000000000000515BI0100001136
258.00150.9.1.3 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). using good quality Vengai woodBI01010001010000000000000515BI01000011370.381cum
268.00250.9.2.3 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction of Engineer in -charge.using Vengai woodBI01010001010000000000000515BI010000113822.05sqm
278.00350.9.4.3 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows ( Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Vengai woodBI01010001010000000000000515BI010000113918.899sqm
288.0049.74.1 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mmBI01010001010000000000000515BI010000114018no
298.0059.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mmBI01010001010000000000000515BI010000114118no
308.00621.1.1.1 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)BI01010001010000000000000515BI0100001142182.25kg
318.00721.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thicknessBI01010001010000000000000515BI010000114360.75sqm
328.00810.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tubeBI01010001010000000000000515BI0100001144360kg
338.0099.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etcBI01010001010000000000000515BI01000011451215kg
349PLASTERINGBI01010001010000000000000515BI0100001146
359.00113.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)BI01010001010000000000000515BI0100001147480.226sqm
369.00213.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plasterBI01010001010000000000000515BI0100001148342.682sqm
379.00313.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).BI01010001010000000000000515BI01000011491829.64sqm
3810FLOORING WORKBI01010001010000000000000515BI0100001150
3910.00111.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.BI01010001010000000000000515BI0100001151499.17sqm
4011PAINTINGBI01010001010000000000000515BI0100001152
4111.00113.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primerBI01010001010000000000000515BI01000011532309.87sqm
4211.00213.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI01000011542309.87sqm
4311.00313.50.1 : Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood)BI01010001010000000000000515BI010000115549.613sqm
4411.00413.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI010000115649.613sqm
4511.00513.65.1 : Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI010000115778.75sqm
4611.00613.71 : Lettering with black Japan pint of approved brand and manufactureBI01010001010000000000000515BI01000011581800per Letter per cm height
4712WATER PROOFINGBI01010001010000000000000515BI0100001159
4812.00122.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)BI01010001010000000000000515BI0100001160342.682sqm
4913RAMPBI01010001010000000000000515BI0100001161
5013.0012.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI01000011622.52cum
5113.0027.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)BI01010001010000000000000515BI01000011634.41cum
5213.00311.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregateBI01010001010000000000000515BI01000011649sqm
5313.00410.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tubeBI01010001010000000000000515BI010000116583kg
5413.00513.65.1 : Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI01000011668.3sqm
5514ElectrificationBI01010001010000000000000515BI0100001167
5614.001od779056/2020_2021 : Supply and installation of 20W LED (2000 Lumens) 4 feet tube fitting with 2kV&lt;br&gt;surge protection and 160-360V voltage protection or equivalent on wall/ ceiling.BI01010001010000000000000515BI010000116840no
5714.002od779058/2020_2021 : Supply and installation of 10W LED wall lamps provided with entire wall mounting arrangement with good closure etc. completeBI01010001010000000000000515BI01000011694no
5814.003od779059/2020_2021 : Supply and Installation of five star rated 48&quot; ceiling fan of ISI mark with standard length of down rod.BI01010001010000000000000515BI010000117016no
5914.004od779060/2020_2021 : Supply, installation, testing and commissioning of wall mounted type double door dust tight and vermin proof IP43 Rated Horizontal 6way TPN MCB DB (DB-1) consists of the following: Single phase / three phase MCB distribution board, 415/240V on surface or recess complete with tinned copper phase and neutral bus bars, earth bar, detachable gland plate, interconnections, phosphated and powder painted including earthing, etc. as required with suitable MCB / RCCB / Isolator&lt;br&gt;6 way (8+18), TPN, MCB DB, double door, horizontal typeBI01010001010000000000000515BI01000011711no
6014.005od779061/2020_2021 : Supply and wiring of circuits for power plugs / circuit mains through existing PVC&lt;br&gt;conduit concealed as following:2 runs of 1.5 Sq.mm FRLS PVC insulated flexible copper wire along with 1.5 Sq.mm PVC insulated flexible copper wire for continuous earthing through existing 20mm PVC conduit.BI01010001010000000000000515BI0100001172220.15metre
6114.006od779062/2020_2021 : Supply and wiring of circuits for power plugs / circuit mains through existing PVC&lt;br&gt;conduit concealed as following:2 runs of 2.5 Sq.mm FRLS PVC insulated flexible copper wire along with 1 run of 1.5 Sq.mm flexible copper wire through existing 20mm PVC conduit.BI01010001010000000000000515BI010000117390metre
6214.007od779063/2020_2021 : Supply and fixing of power sockets, controlling Modular type switches, and&lt;br&gt;mounting boxes.Supply and fixing of 16A independent switch and socket on&lt;br&gt;suitable size G.I. boxBI01010001010000000000000515BI01000011749no
6314.008od779064/2020_2021 : Supply of all materials and labour charges of point wiring for 240V AC circuits&lt;br&gt;through existing PVC conuduits using 1.5 Sq.mm FRLS PVC insulated flexible&lt;br&gt;copper wire along with 1.5 Sq.mm FRLS PVC insulated flexible copper wire for&lt;br&gt;continuous earthing with modular switch, modular base, cover plate, suitable GI box etc. (excluding 1.5 Sq.mm FRLS PVC insulated flexible copper wire circuit mains) for the following:One light point controlled by one No. 6A SP switch.BI01010001010000000000000515BI010000117517no
6414.009od779065/2020_2021 : Supply of all materials and labour charges of point wiring for 240V AC circuits&lt;br&gt;through existing PVC conuduits using 1.5 Sq.mm FRLS PVC insulated flexible&lt;br&gt;copper wire along with 1.5 Sq.mm FRLS PVC insulated flexible copper wire for&lt;br&gt;continuous earthing with modular switch, modular base, cover plate, suitable GI box etc. (excluding 1.5 Sq.mm FRLS PVC insulated flexible copper wire circuit mains) for the following:Two light point controlled by one No. 6A SP switch.BI01010001010000000000000515BI01000011762no
6514.01od779066/2020_2021 : Supply of all materials and labour charges of point wiring for 240V AC circuit through existing PVC conuduits using 1.5 Sq.mm FRLS PVC insulated flexible&lt;br&gt;copper wire along with 1.5 Sq.mm FRLS PVC insulated flexible copper wire for&lt;br&gt;continuous earthing with modular switch, modular base, cover plate, suitable GI box etc. (excluding 1.5 Sq.mm FRLS PVC insulated flexible copper wire circuit mains) for the following:Three light point controlled by one No. 6A SP switch.BI01010001010000000000000515BI010000117710no
6614.011od779067/2020_2021 : Supply of all materials and labour charges of point wiring for 240V AC circuits&lt;br&gt;through existing PVC conuduits using 1.5 Sq.mm FRLS PVC insulated flexible&lt;br&gt;copper wire along with 1.5 Sq.mm FRLS PVC insulated flexible copper wire for&lt;br&gt;continuous earthing with modular switch, modular base, cover plate, suitable GI box etc. (excluding 1.5 Sq.mm FRLS PVC insulated flexible copper wire circuit mains) for the following:One fan point controlled by one switch using step type electronic regulator.BI01010001010000000000000515BI010000117816no
6714.012od779068/2020_2021 : Supplying and fixing of following sizes of medium class 32mm Dia PVC conduit&lt;br&gt;along with accessories in surface/recess including&lt;br&gt;cutting the wall and making good the same in case of recessed conduit as required.32 mm dia. ISI marked, PVC conduit, medium classBI01010001010000000000000515BI010000117930metre
6814.013od779069/2020_2021 : Supply and laying / fixing, giving and termination of the following copper conductor&lt;br&gt;/ strips for effective earthing of the system as per IS 3043.BI01010001010000000000000515BI010000118045metre
6914.014od779070/2020_2021 : Supply and providing efficient 1500mm long, 38mm dia. G.I. Pipe earthing&lt;br&gt;including filling the pit with charcoal and salt. 1500mm long, 38mm dia. G.I. Pipe&lt;br&gt;earthing including filling the pit with charcoal and salt.&lt;br&gt;BI01010001010000000000000515BI01000011812no
7014.0151.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mmBI01010001010000000000000515BI0100001182450metre

AI Tender Summary

OUR REF NO 25428746
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 79.21 Lakhs
LAST DATE 25-09-2020
Authority
Authority Name Kerala Institute Of Local Administration
Work Description Kiifb - Construction Of New Building To Ghss Munnoorcode In Pookkottukavu Grama Panchayath .
Basic Detail
Tender No 14/CL11/CMPMU/KILAKIIFB /20-21
Bidding Type Tender
Location
City POOKKOTTUKAVU GRAMA PANCHAYATH.
State Kerala
Key Dates
Publish Date 14 Sep 2020
Submission Date 25 Sep 2020
Open Date 29 Sep 2020
Finance
Tender Value 79.21 Lakhs
Tender Fee 2800
EMD 50000
Exemption Not Available
Document List
epaymentform.pdf
PRELIMINARYAGREEMENT.pdf
UNDERTAKINGOFCOMPOSITETENDER.pdf
specialconditions.pdf
BOQ_546367.xls
appdtenderdocument.pdf
Tendernotice_1.pdf
CDC303F6-FA3F-4AB3-93E0-59046AE7C44D.html
DECLARATION.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 14, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 25, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 29, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

epaymentform.pdf

pdf

PRELIMINARYAGREEMENT.pdf

pdf

UNDERTAKINGOFCOMPOSITETENDER.pdf

pdf

specialconditions.pdf

xls

BOQ_546367.xls

pdf

appdtenderdocument.pdf

pdf

Tendernotice_1.pdf

html

CDC303F6-FA3F-4AB3-93E0-59046AE7C44D.html

pdf

DECLARATION.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders