Supply, Installation & Commissioning-Karnataka

Karnataka State Electronics Development Corporation Limited-KEONICS has published Supply, Installation & Commissioning. Submission Date for this Tender is 02-09-2020. Casks Barrels and Drums Tenders in Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

25242914
Supply, Installation & Commissioning
Open Tender
Indian
Karnataka
02-09-2020

Tender Details

Supply, Installation & Commissioning 1. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed,Galvanised,Steel Strip (Except 2Cx10sq.Mm Wire Armoured) Confirming To Is 3975:1990 (No. Of Strip Indicated In Gtp) And Extruded Pvc Outer Sheathed Armoured Cable With Specified Is 1554 Part 1:1988 And Confirming To The Attached Gtp Of Group A. As Per The Direction Of Work Incharge Engineer 3.5 Core 35 Sqmm Pwd Electrical Sr 2019 20 Page No 40, Item No 6.4.6, 2. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed,Galvanised,Steel Strip Except 2Cx10sq.Mm Wire Armoured Confirming To Is 3975:1990 No. Of Strip Indicated In Gtp And Extruded Pvc Outer Sheathed Armoured Cable With Specified Is 1554 Part 1:1988 And Confirming To The Attached Gtp Of Group A. As Per The Direction Of Work Incharge Engineer 3.5 Core 25 Sqmm Pwd Electrical Sr 2019 20 Page No 40, Item No 6.4.5, 3. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe Stoneware Pipe On Wall On Pole As Required. As Per The Direction Of Work Incharge Engineer 25 Sqmm To 75 Sqmm Pwd Electrical Sr 2019 20 Page No 41, Item No 6.5.2, 4. Supplying And Fixing Of Heavy Duty Cable Glands Suitable For Ug Cable Of 1.1 Kv Class Metal Only 25Mm Dia Pwd Electrical Sr 2019 20 Page No 42, Item No 6.11.2, 5. Supplying And Fixing Of Heavy Duty Cable Glands Suitable For Ug Cable Of 1.1 Kv Class Metal Only 45Mm Dia Pwd Electrical Sr 2019 20 Page No 42, Item No 6.11.4, 6. Supply And Laying Double Walled Corrugated Dwc Hdpe Pipe Including All Necessary Connecting Sockets Couplings Tees Bends End Caps Of Same Materials In Exisiting Trench As Per Is 14930 Part Ii Suitable For Drawing Under Ground Cables.A G B 50Mm Od 38Mm Id Pwd Electrical Sr 2014 15 Page No 63, Item No 7.20.2, 7. Supplying And Running Gi Copper Conductor For Grounding And Along With Other Wires In Conduit System Of Wiring Using Necessary Suitable Size Clamps, Nails, Guttas Spacers Etc.. 64 7.22 Pwd Electrical Sr 2019 20 Page No 44, Item No 6.18.6 Copper Wire 8 Swg, 8. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point For Wire Of The Following Sizes.F 25 Sqmm Long Barrel Pwd Electrical Sr 2019 20 Page No 64, Item No 6.17.7, 9. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point For Wire Of The Following Sizes.F 35 Sqmm Long Barrel Pwd Electrical Sr 2019 20 Page No 43, Item No 6.17.8, 10. Led Efficiency 130 Lm W At 1W And Fixture Efficiency 80 Lm W With Nominal Cri 75. System Rating Shall Be 50000 Hours At Lumen Maintenance Of 70Percentage, System Efficacy 80 Lm W. Input Voltage Range Of Ac 100 V 240 V, Compliance To Lm 79 And Lm 80, 50 60 Hz. Warranty Of 5 Years Against Any Manufacturing Defect When Working Under Standard Electrical Conditions. The Led Flood Light Must Be Installed With Suitable Individual Bus Bar Box With Fuse Control. The Cost Includes Labor Charges Of Installation, Transportation Cost And Necessary Fixing Mounting Kit Clamps Suitable For The Site Condition As Per The Direction Of The Engineer In Charge Of The Work. Led Efficiency 130 Lm W At 1W And Fixture Efficiency 80 Lm W With Nominal Cri 75. System Rating Shall Be 50000 Hours At Lumen Maintenance Of 70Percentage, System Efficacy 80 Lm W. Input Voltage Range Of Ac 100 V 240 V, Compliance To Lm 79 And Lm 80, 50 60 Hz. Warranty Of 5 Years Against Any Manufacturing Defect When Working Under Standard Electrical Conditions. The Led Flood Light Must Be Installed With Suitable Individual Bus Bar Box With Fuse Control. The Cost Includes Labor Charges Of Installation, Transportation Cost And Necessary Fixing Mounting Kit Clamps Suitable For The Site Condition As Per The Direction Of The Engineer In Charge Of The Work., 11. Suplying And Fixing 2Mm Thick Perforated Cable Tray With Powder Coated Paint On Existing Ms Angle Support Using Necessary Gi Bolts Nuts And Washer Or Welding As Required. 63 7.19 Pwd Electrical Sr 2019 20, Pgno.Xix, It.No.556 150X50mm, 12. Ksrb 2 2 : Earthwork Excavation By Manual Means For Foundation Of Buildings, Water Supply And Sanitary Lines And Electrical Conduits Etc, Either In Pits Or In Trenches 1.5M And Above In Width, In Soil Not Exceeding 1.5 M. In Depth Including Dressing The Bottom And Sides Of Pits And Trenches, Stacking The Excavated Soil Clear From Edges Of Excavation With Lead Upto 50 M. Including Breaking Of Clods Complete As Per Specifications In Ordinary Soil.. Pwd Civil Sr 2018 19, Pg.No.6, It.No.2.3, 13. Ksrb 4.2.2 : Providing And Laying In Position Reinforced Cement Concrete Of Design Mix M20 With Opc @ 320Kgs, With 20Mm And Down Size Graded Granite Metal Coarse Aggregates @0.69Cum And Fine Aggregtes @ 0.460 Cum, With Super Plasticisers @ 3 Liters Confirming To Is 9103 1999 Reafirmed 2008, Machine Mixed, Concrete Laid In Layers Not Exceeding 15 Cms Thick, Vibrated For All Works In Foundation For Footings, Pedastals, Retaining Walls, Return Walls, Walls Any Thickness Including Attached Pilasters, Columnspillars, Posts, Struts, Buttresses, Bed Blocks, Anchor Blocks And Plinths Etc., Including Cost Of All Materials, Labour, Hom Curing, Complete But Excluding Cost Of Reinforcement As Per Specifications.Specification No. Kbs 4.1, 4.6 Pwd Civil Sr 2018 19, Pg.No.13, It.No.4.11, 14. Fabricating, Supplying And Erection Of Mtrs Long Hot Dip Galvanized Octagonal Pole With Bsen 10025 Grade S 355 Jo Steel Plate For Shaft, Is 2062 For Base Plate With Door Opening Arrangements, Including Suitable Boards, Bakelite Sheet And Mcbs As Per Is Specifications Suitable To Withstand The Wind Speed Of 47 M Sec For Mtrs Pole In Single Section And Single Joint Welded As Per Is 9595 Is 10178Aws Having Dimensions Bottom Mm, Top Mm With 3Mm Thick, Suitable Base Plate And 4Nos Of Long J Bolts Along With Template And The Pole Shall Be Hot Dip Galvanized In Single Dipping With Not Less Than 65Micron As Per Astm A123 And 153 Etc., With Out Foundation For Foundation Details Refer Prevailing Civil Sr 34 35 5.14 Pwd Electrical Sr 2019 20 Page No 34 Item No 5.14.1 And 5.14.8 3 Meters Top 70Mm And Bottom 130Mm Dia, 15. Supplying, Fixing, Wiring, Earth Electrode For Grounding Conduits, I.C Cutouts And Other Equipments On The Meter Board Using 40Mm Dia 2.90Mm Thick Gi Pipe 2.5 Mtr Long Buried In A Pit The Pit Should Be Filled With Equal Proprotion Of Salt And Charcoal 150Mm Alround The Pipe To Complete Depth The Connection From The Pipe To The Conduit Etc, Is To Be Established Through Gi Wire Of Size As Per Isi Specification 7.3.3 Of Is 732 Using 12Mm Dia Bolts, Nuts, Washers And Checknuts Etc, The Pipe Shall Have 16 Through Holes Of 122 Mm Dia 55 7.1 Pwd Electrical Sr 2019 20 Page No 40 Item No 6.1, 16. Fabricating, Supplying And Mounting M.S Box For Panel Board Fully Weather Proof Suitable For Floor Wall Mounting With Suitable Locating Arrangements With Suitable Size Clamps, Necessary Cable Entry Pipe With Gland And The Box Should Be Finished With 2 Coats Of Red Oxide Primer Paint And Finally Finished With Approved Enamel Metal Paint The Panel Board Should Be Furnished With 3 Phase Neutral Bus Bar, With Suitable Ms Angle Iron And Ms Flat Work, Microprocessor Basel Electronic Timers, Suitable 4 Pole Power Contactor, Mccbs, Modular Mcb Devices Tripper , Switch Disconnect Or Fuse Unit Hrc Type , Hrc Fuses, Hrc Fuse Link, Up To 6 3 Amps The Panel Board Unit Must Also Include Required Copper Wire, Lugs, Ferrules, Socket, Switches, And Other Necessary Accessories Required For Safer Operation Of Led Lighting System The Cost Includes Necessary Earth Work, Foundation With M 20 Concrete For Mounting Panel Board, Transportation Cost, All Material And Labor Charges For Assembling And Installation Of The Same As Per The Direction Of The Engineer In Charge Of The Work.,

Key Value

Document Fees
INR 550 /-
EMD
INR 60000.0 /-
Tender Value
Refer document

BOQ Items

Sl No Item Code Item Name Item Description Unit Quantity
1
01/TEND/2020/RK/302/01 Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed,galvanised,steel strip (except 2CX10Sq.mm wire armoured) confirming to IS 3975:1990 (No. of Strip indicated in GTP) AND extruded PVC outer sheathed armoured cable with specified IS 1554 Part 1:1988 AND confirming to the attached GTP of GROUP A. as per the direction of work incharge engineer 3.5 core 35 sqmm PWD Electrical SR 2019 20 Page No 40, Item No 6.4.6 Specification: As specified in the tender document.
Nos
800
2
01/TEND/2020/RK/302/02 Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed,galvanised,steel strip except 2CX10Sq.mm wire armoured confirming to IS 3975:1990 No. of Strip indicated in GTP AND extruded PVC outer sheathed armoured cable with specified IS 1554 Part 1:1988 AND confirming to the attached GTP of GROUP A. as per the direction of work incharge engineer 3.5 core 25 sqmm PWD Electrical SR 2019 20 Page No 40, Item No 6.4.5 Specification: As specified in the tender document.
Nos
400
3
01/TEND/2020/RK/302/03 Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. as per the direction of work incharge engineer 25 sqmm to 75 sqmm PWD Electrical SR 2019 20 Page No 41, Item No 6.5.2 Specification: As specified in the tender document.
Nos
1200
4
01/TEND/2020/RK/302/04 Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 25mm dia PWD Electrical SR 2019 20 Page No 42, Item No 6.11.2 Specification: As specified in the tender document.
Nos
10
5
01/TEND/2020/RK/302/05 Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 45mm dia PWD Electrical SR 2019 20 Page No 42, Item No 6.11.4 Specification: As specified in the tender document.
Nos
10
6
01/TEND/2020/RK/302/06 Supply and laying double walled corrugated DWC HDPE Pipe including all necessary connecting Sockets Couplings Tees Bends End caps of same materials in exisiting trench as per IS 14930 part II suitable for drawing under ground cables.a g b 50mm OD 38mm ID PWD Electrical SR 2014 15 Page No 63, Item No 7.20.2 Specification: As specified in the tender document.
Nos
1000
7
01/TEND/2020/RK/302/07 Supplying and running GI Copper conductor for grounding and along with other wires in conduit system of wiring using necessary suitable size clamps, nails, guttas spacers etc.. 64 7.22 PWD Electrical SR 2019 20 Page No 44, Item No 6.18.6 Copper wire 8 SWG Specification: As specified in the tender document.
Nos
50
8
01/TEND/2020/RK/302/08 Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.f 25 sqmm Long Barrel PWD Electrical SR 2019 20 Page No 64, Item No 6.17.7 Specification: As specified in the tender document.
Nos
50
9
01/TEND/2020/RK/302/09 Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.f 35 sqmm Long Barrel PWD Electrical SR 2019 20 Page No 43, Item No 6.17.8 Specification: As specified in the tender document.
Nos
30
10
01/TEND/2020/RK/302/10 LED efficiency 130 lm W at 1W AND fixture efficiency 80 lm W with nominal CRI 75. System rating shall be 50000 hours at lumen maintenance of 70PERCENTAGE, system efficacy 80 lm W. Input voltage range of AC 100 V 240 V, compliance to LM 79 AND LM 80, 50 60 Hz. Warranty of 5 years against any manufacturing defect when working under standard electrical conditions. The LED flood light must be installed with suitable individual bus bar box with fuse control. The cost includes labor charges of installation, transportation cost and necessary fixing mounting kit clamps suitable for the site condition as per the direction of the engineer in charge of the work. LED efficiency 130 lm W at 1W AND fixture efficiency 80 lm W with nominal CRI 75. System rating shall be 50000 hours at lumen maintenance of 70PERCENTAGE, system efficacy 80 lm W. Input voltage range of AC 100 V 240 V, compliance to LM 79 AND LM 80, 50 60 Hz. Warranty of 5 years against any manufacturing defect when working under standard electrical conditions. The LED flood light must be installed with suitable individual bus bar box with fuse control. The cost includes labor charges of installation, transportation cost and necessary fixing mounting kit clamps suitable for the site condition as per the direction of the engineer in charge of the work. Specification: As specified in the tender document.
Nos
60
11
01/TEND/2020/RK/302/11 Suplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts nuts and washer or welding as required. 63 7.19 PWD Electrical SR 2019 20, PgNo.XIX, It.No.556 150x50mm Specification: As specified in the tender document.
Nos
1200
12
01/TEND/2020/RK/302/12 KSRB 2 2 : Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications in ordinary soil.. PWD Civil SR 2018 19, Pg.No.6, It.No.2.3 Specification: As specified in the tender document.
Nos
5
13
01/TEND/2020/RK/302/13 KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of Design Mix M20 with OPC @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to IS 9103 1999 reafirmed 2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls any thickness including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks AND plinths etc., including cost of all materials, labour, HOM curing, complete but excluding cost of reinforcement as per specifications.Specification No. KBS 4.1, 4.6 PWD Civil SR 2018 19, Pg.No.13, It.No.4.11 Specification: As specified in the tender document.
Nos
6
14
01/TEND/2020/RK/302/14 Fabricating, supplying and erection of Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m sec for Mtrs pole in single section and single joint welded as per IS 9595 IS 10178AWS having dimensions bottom mm, top mm with 3mm thick, suitable base plate and 4Nos of long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM A123 and 153 etc., With out foundation for foundation details refer prevailing Civil SR 34 35 5.14 PWD Electrical SR 2019 20 Page No 34 Item No 5.14.1 AND 5.14.8 3 meters Top 70mm and bottom 130mm dia Specification: As specified in the tender document.
Nos
60
15
01/TEND/2020/RK/302/15 Supplying, fixing, wiring, earth electrode for grounding conduits, I.C cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia 55 7.1 PWD Electrical SR 2019 20 Page No 40 Item No 6.1 Specification: As specified in the tender document.
Nos
6
16
01/TEND/2020/RK/302/16 Fabricating, Supplying AND mounting M.S box for panel board fully weather proof Suitable for floor wall mounting with suitable locating arrangements with suitable size clamps, necessary cable entry pipe with gland AND the box should be finished with 2 coats of red oxide primer paint AND finally finished with approved enamel metal paint The panel board should be furnished with 3 phase neutral bus bar, with suitable MS angle iron AND MS flat work, microprocessor Basel electronic timers, suitable 4 pole power contactor, MCCBs, modular MCB devices Tripper , Switch disconnect or fuse unit HRC type , HRC fuses, HRC fuse link, up to 6 3 Amps The panel board unit must also include required copper wire, lugs, ferrules, socket, switches, and other necessary accessories required for safer operation of LED lighting system The cost includes necessary earth work, foundation with M 20 concrete for mounting panel board, transportation cost, all material and labor charges for assembling and installation of the same as per the direction of the engineer in charge of the work. Specification: As specified in the tender document.
Nos
3
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail