Providing Internal Electrification Conceal Type At Double Storied Administrative Building For Krishi Vigyan Kendra At Salema Dhalai Tripura

BOQ

Name of Work: Proposed construction of Double storied Administrative Building for Krishi Vigyan Kendra at Salema, Dhalai, Tripura/ SH:- Building constuction including water supply & santary installation/ SH: Providing Internal Electrification (conceal type) thereof.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in existing PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amp moduler type switch, switch board, cover plate, GI box including necessary connection etc. as required [As per rate approved by CE (building)]1142Nos
22Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required:- (As per TSR-2017 Sl. No.403)230Nos
33Providing and fixing of 3/6 pin 16 / 20 amps plug point with modular type 16/20 amps switch and socket including connection with 2 x 2.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required:- (As per TSR-2017 Sl. No.204)328Nos
44Wiring for Circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- (As per TSR-2017 Sl. No.501)4
54.011 X 2.5 sq mm (Green Colour)5450Mtrs
64.021 X 4 sq mm (Green Colour)6410Mtrs
74.031 X 6 sq mm (Green Colour)7130Mtrs
84.041 X 10 sq mm (Green Colour)810Mtrs
94.052 X 2.5 sq mm9450Mtrs
104.062 X 4 sq mm10410Mtrs
114.074 X 6 sq mm11130Mtrs
124.084 X 10 sq mm1210Mtrs
135Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required:-(As per TSR-2017 Sl. No.607)13
145.016 module GI switch board:-1414Nos
156Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required:-(As per TSR-2017 Sl. No.608)15
166.016 module :-1614Nos
177Supplying and fixing of the following modular accessories including necessary connection etc. as required:-(As per TSR-2017 Sl. No.609)17
187.0120/25 amps single phase motor starter switch (2M):-184Nos
198Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12\"x 12\" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required:- (As per TSR 2017, Sl- 703)192Sets
209Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required. (As per TSR 2017, Sl- 705)202Sets
2110Supply and fixing of 25 x 3mm copper strip on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals. (As per TSR 2017, Sl- 716)2125Mtrs
2211Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\"x 12\" having locking arrangement including CC work, holes on earth pipe etc. as required.:- (As per TSR 2017, Sl- 701)221Sets
2312Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. (As per TSR 2017, Sl- 702)231Sets
2413Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. (As per TSR 2017, Sl- 706)2415Mtrs
2514Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required:- (As per TSR 2017, Sl- 711)2515Mtrs
2615Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated copper conductor cable(FR) conforming to IS 374 (1979), BEE 5 star:-(As per TSR 2017, Sl- 800)2626Nos
2716Supplying & fixing of electronic modular 5 step fan regulator in existing switch board including necessary connection etc as required:-(As per TSR 2017, Sl- 808)2726Nos
2817Supplying & installation of 230 mm sweep metalic body exhaust fan including connection etc as required:-(As per TSR 2017, Sl- 822)2816Nos
2918Supplying & installation of 300 mm sweep light duty metalic body exhaust fan including connection etc as required:-(As per TSR 2017, Sl- 823)292Nos
3019Supplying & installation of shutter for 230/300 mm sweep metalic body exhaust fan in the existing hole as required:-(As per approved rate vide letter no - 5(205) / ACE/PROJECT/ 2017/ 7150-52, Dated- 21st Dec. 2017)3018Nos
3120Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required::-(As per TSR 2017, Sl- 1318)3118Nos
3221Supplying and fixing of Single box type LED light fixture suitable upto 20 watt LED tube with lamp [As per rate approved by CE (building)] :-3244Nos
3322Supplying and fixing of following accessories for LED luminaries including necessary connection etc. as required:-[As per rate approved by CE (building)]33
3422.0112-18 watt (round/square shaped) LED light fixture:-3418Nos
3523Supplying and fixing of 10 watt LED retrofit lamp with polycarbonate body and aluminium heat sink including necessary connection etc as reqd:- (As per approved rate vide letter no - 5(205) / ACE/PROJECT/ 2017/ 7150-52, Dated- 21st Dec. 2017)3532Nos
3624Supplying and fixing of following outdoor LED luminaries complete with powder coated die cast housing and heat resistant tempered glass/diffuser including necessary connection etc. as required:-[As per rate approved by CE (building)]36
3724.0145-48 watt LED street light fixture (IP 65):-377Nos
3825Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(As per TSR 2017, Sl- 1301)38
3925.0140 mm dia:-3910Mtrs
4026Supplying and fixing of outdoor pole fabricated out of GI pipe ISI marked (medium gauge) having four section - 125mm dia upto 2 mtr (bottom from foundation base) 100 mm dia upto 2 mtr long (middle) , 80 mm dia upto 1.5 mtr and 50 mm dia upto 1.5 mtr welded with reducer sockets at every joint complete with 1 no arm of 40 mm dia 1.5 mtr long welded at the top of 50 mm dia G.I pipe having a vertical height of 7 mtr. Above the foundation base complete with 300mmX300mmX6mm thick MS sheet foundation plate welded at bottom with 4 nos foundation bolt in the cc foundation base in/c drilling holes at the bottom of the pipe for drawing of wire, complete with erection of the same in cc foundation base in/c excavation and refilling earthed work, painting the G.I pole with black paint (2 coat) over one coat of red oxide etc. as required as per direction of site engineer.<G.I pipe of Jindal make>402Job
4127Supplying and laying of the following XLPE insulated PVC sheathed alluminum armoured cable including connection etc as required.(As per TSR 2017, Sl- 1101)41
4227.013 core 4 Sq mm:-42300Mtrs
4328Drawing of armoured / un-armoured cable with proper saddeling etc as required:-(As per TSR 2017, Sl- 1307)43200Mtrs
4429Excavation of earth for cable tranch of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks/ metre for protection including ramming, consolidating to the original shape as required:-(As per TSR 2017, Sl- 1306)44100Mtrs
4530Supplying and fixing of powder coated sheet steel enclosure on surface/recess, suitable for 415 volts MCCB (TP/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required:-(As per TSR 2017, Sl- 1008)45
4630.01Enclosure suitable for MCCB upto 100 amps:-461Nos
4731Supplying and fixing of the following ratings switch disconnector fuse unit(main switch)made of sheet steel enclosure with all accessories including drilling holes on the board/MS clamp and necessary connection etc. as required. (As per TSR 2017, Sl- 1017)47
4831.0125 to 125 amps FP MCCB :-481Nos
4932Supplying and fixing of the following ratings Bus bar chamber of copper strip made of sheet steel enclosure with all accessories including drilling holes on the board/MS clamp and necessary connection etc. as required (As per TSR 2017, Sl- 1001)49
5032.0163 Amps 415 volts four strip of size (455mmx330mmx120mm):-502Nos
5133Supplying and fixing of the following ratings switch disconnector fuse unit(main switch)made of sheet steel enclosure with all accessories including drilling holes on the board/MS clamp and necessary connection etc. as required. (As per TSR 2017, Sl- 1002)51
5233.01100 amps 415 volts TPN (rewireable)521Nos
5334Supplying and fixing of powder coated sheet steel enclosure on surface/recess, suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as require:- (As per TSR 2017, Sl- 1006)53
5434.012+10 / 12 way MCB DB (double door):-546Nos
5534.022 way MCB DB (single door):-551Nos
5635Supplying & fixing of following ratings MCB B/C curve having breaking capacity 10 KA in the existing MCB DB including connection as required:-(As per TSR 2017, Sl- 1013)56
5735.016 to 32 amps SP MCB:-5762Nos
5836Supplying & fixing of following ratings isolator in the existing MCB DB including connection etc as required:-(As per TSR 2017, Sl- 1014)58
5936.0140 amps DP isolator:-596Nos
6037Supplying and fixing of the following electrical accessories including necessary connection etc. as required.:-(As per TSR 2017, Sl- 604)60
6137.013mm thick bakelite sheet:-61150Sq Inch
6237.02Ding dong/Musical call bell622Nos
6337.0332 amp DP kit kat switch634Nos
6438Supplying and installation ABC powder (MAP 90) fire Extinguisher of capacity 6 Kg with five years warranty as required (Make: Secure Zone/ Cease Fire/Fire shield, with BIS certification) (Rate as per analysis):-641Nos

AI Tender Summary

OUR REF NO 25216422
AUTHORITY Government Departments
TENDER VALUE 6.19 Lakhs
LAST DATE 08-09-2020
Authority
Authority Name Public Works Department
Work Description Providing Internal Electrification Conceal Type At Double Storied Administrative Building For Krishi Vigyan Kendra At Salema Dhalai Tripura
Basic Detail
Tender No EE-IED/AMB/2020-21/42
Bidding Type Tender
Location
City salema
State Tripura
Key Dates
Publish Date 20 Aug 2020
Submission Date 08 Sep 2020
Open Date 09 Sep 2020
Finance
Tender Value 6.19 Lakhs
Tender Fee 1000
EMD 6198
Exemption Not Available
Document List
E-DNIT42.pdf
BOQ_12442.xls
1073C025-7BAB-453D-9702-9DDA1E459F83.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 08, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 09, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

E-DNIT42.pdf

xls

BOQ_12442.xls

html

1073C025-7BAB-453D-9702-9DDA1E459F83.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders