Construction Of Cultural Stage And Development Of Mandaveli Thidal At Koodapakkam Sub Work Electrification Work For Illumination Facilities To The Kallbaddi Court And Volleyball Court 2Nd Cal
Tender Value
9.63 Lakhs
Estimated cost
Bid Submission
28 Aug 2020
0 days left
EMD
19268
Bank guarantee accepted
Document Fee
525
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
koodapakkam → Puducherry
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Cultural Stage And Development Of Mandaveli Thidal At Koodapakkam Sub Work Electrification Work For Illumination Facilities To The Kallbaddi Court And Volleyball Court 2Nd Cal
BOQ
| Name of Work: Construction of Cultural Stage and development of Mandaveli Thidal at Koodapakkam in Ossudu Constituency, Puducherry.Sub work: Electrification work for illumination facilities to the Kabaddi court and Volley ball court. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | CODE NO.12.2.2: Supply and erection MS swaged tublar pole with base plate and single ornamental bracket two coats coats of zinc chromate and two coats of aluminium / epoxy painting. Pole height-8 mt. Pole dimension 139.7 x 4.5 x 4500mm , 114.3 x 3.65 x 1750mm, 88.9 x 3.25mm x 1750mm, bracket dimen+C8sion 60.3 X 3.65mm x 2700mm - 1no, base plate dimension 300mm x 300mm x 5mm, overall height - 9.5mts including excavation of earth column- 750x 750 x1650mm and cement concrete 1: 2: 4 of volume 750 x750 x 1650mm filling and capping above ground level 450mm dia x 600mm height. One coat of zinc chromate and two coat of aluminium / epoxy painting should be done after erection of the pole and inclusive of suitable length 1.25mt.- 2 nos. of 40mm dia medium class GI pipe for cable raising as required\n | BI01010001010000000000000515BI0100001113 | 16 | No. |
| 2 | 2 | NON PSR ITEM: Supplying and fixing of LED flood light luminaries 200W (Power output). White light with pressing die cast aluminium. Diffuser clear toughen gals housing IP65/66. efficency> 110Lm/watt. LED chip package 5050, CRI>70. rated voltage: 240V, rated frequency 50HZ safety operating voltage range 140v-280v AC and with necessary over voltage. short circuit open circuit & surge protection. The luminaries shall be warranted for three years on site replacement / rectification. The NABL type test report. Driver safety test report as per BIS. LM80 report from chip manufacturer shall be furnished. (Make: Philips/Havells/Crompton/ Everady/Bajaj). The rate is inclusive of all taxes.\n | BI01010001010000000000000515BI0100001114 | 32 | No. |
| 3 | 3 | CODE NO.1.5.1: Supplying and drawing of 1.5 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/recessed, PVC/steel conduit/PVC casing and capping as required.Make: Finolex/Polycab:- | BI01010001010000000000000515BI0100001115 | 90 | Mtr. |
| 4 | 4 | CODE NO.1.5.2: Supplying and drawing of 2.5 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/recessed, PVC/steel conduit/PVC casing and capping as required.Make: Finolex/Polycab:- | BI01010001010000000000000515BI0100001116 | 470 | Mtr. |
| 5 | 5 | CODE NO.1.5.3: Supplying and drawing of 4.0 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/recessed, PVC/steel conduit/PVC casing and capping as required.Make: Finolex/Polycab:- | BI01010001010000000000000515BI0100001117 | 90 | Mtr. |
| 6 | 6 | CODE NO.1.5.5: Supplying and drawing of 10.0 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/recessed, PVC/steel conduit/PVC casing and capping as required.Make: Finolex/Polycab:- | BI01010001010000000000000515BI0100001118 | 90 | Mtr. |
| 7 | 7 | CODE NO.3326: Supplying of 280 x 170 x 130 mm outer (240 x 130 x 110 mm inner) size PVC junction box- Sintex. | BI01010001010000000000000515BI0100001119 | 17 | each |
| 8 | 8 | CODE NO.2.2.2.3: Supplying and fixing 6 amps to 32 amps rating ,Double pole,240 volts,'c' series,miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. Make:Siemens/ABB/L&T Hager | BI01010001010000000000000515BI0100001120 | 20 | each |
| 9 | 9 | CODE NO.3211: Supplying of 4 x 16sqmm armoured aluminium U.G cable - 1.1 KV grade. Make:Finolex/Polycab\n | BI01010001010000000000000515BI0100001121 | 100 | Mtr. |
| 10 | 10 | CODE NO.3212: Supplying of 4 x 25sqmm armoured aluminium U.G cable - 1.1 KV grade. Make:Finolex/Polycab | BI01010001010000000000000515BI0100001122 | 200 | Mtr. |
| 11 | 11 | CODE NO.3213: Sypplying of 4x 50sqmm armoured aluminium U.G cable - 1.1 KV grade.Make:Finolex/Polycab\n | BI01010001010000000000000515BI0100001123 | 80 | Mtr. |
| 12 | 12 | CODE NO.11.1.1: Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of size not exceeding 25sq.mm direct in ground including excavation, sand cushioning, protective covering and refillilng the trench etc as required in Mud Road | BI01010001010000000000000515BI0100001124 | 200 | Mtr. |
| 13 | 13 | CODE NO.11.15.4: Supplying and making end termination with copper gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required:4 X 25 Sq.mm | BI01010001010000000000000515BI0100001125 | 30 | Set |
| 14 | 14 | CODE NO.11.15..5: Supplying and making end termination with copper gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required: 4 X 50 Sq.mm | BI01010001010000000000000515BI0100001126 | 2 | Set |
| 15 | 15 | CODE NO.1134A: Supplying of 50 mm dia. GI pipe medium class | BI01010001010000000000000515BI0100001127 | 50 | Mtr. |
| 16 | 16 | CODE NO.3267: Supplying and fixing 25mm dia. green spring hose | BI01010001010000000000000515BI0100001128 | 200 | Mtr. |
| 17 | 17 | CODE NO.3271: Supplying and fixing 75mm dia. green spring hose | BI01010001010000000000000515BI0100001129 | 25 | Mtr. |
| 18 | 18 | CODE NO.1.1.1.2: Supplying and fixing of following size of PVC conduit alongwith the accessories in surface/recess Conduit including cutting the wall and making good the same in case of recessed conduit as required.Make:Avonplast/Vijaya:- 25mm dia | BI01010001010000000000000515BI0100001130 | 15 | Mtr. |
| 19 | 19 | CODE NO.1.4.7: Supplying and fixing of modular GI box for 12 module . including cutting the wall and making good the same as required - Make:Legrand-Mosaic/MK/Siemens. | BI01010001010000000000000515BI0100001131 | 2 | each |
| 20 | 20 | CODE NO.1.7.4.7: Supplying and fixing of modular base and cover plate for 12 module on the existing modular metal boxes etc. as required. Make: Legrand-Mosaic/MK/Siemens/Crabtree/ABB. | BI01010001010000000000000515BI0100001132 | 2 | each |
| 21 | 21 | CODE NO.1.7.3.1: Supplying and fixing of S.P. 5/6 amps, one way modular switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.Make:\nLegrand-Mosaic/ABB:- | BI01010001010000000000000515BI0100001133 | 10 | each |
| 22 | 22 | CODE NO.1.7.3.3: Supplying and fixing of 3 pin 5/6 amps modular socket outlet, on the existing modular plate and switch box including connections but excluding modular plate etc.as required.Make:Legrand-Mosaic/ABB:- | BI01010001010000000000000515BI0100001134 | 4 | each |
| 23 | 23 | CODE NO.1.7.3.4: Supplying and fixing of S.P.15/16 amps, one way modular switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.Make:Legrand-Mosaic/ABB:- | BI01010001010000000000000515BI0100001135 | 4 | each |
| 24 | 24 | CODE NO.1.7.3.6: Supplying and fixing of 3 pin 15/16 amps modular socket outlet, on the existing modular plate and switch box including connections but excluding modular plate etc.as required.Make:Legrand-Mosaic/ABB:- | BI01010001010000000000000515BI0100001136 | 4 | each |
| 25 | 25 | CODE NO.3051: Supplying of 1 x 40W box type single tube light fitting with copper choke & starter without tube. Make: Philips/Bajaj | BI01010001010000000000000515BI0100001137 | 6 | each |
| 26 | 26 | CODE NO.3112: Supplying and fixing 40W tube light. Make: Philips | BI01010001010000000000000515BI0100001138 | 6 | No. |
| 27 | 27 | CODE NO.1.8.1.5: Installation, testing and commissioning of prewired, all kind of surface mount light fittings, complete with all accessories etc. directly on high ceiling/wall, including connections with 16/0.20 mm twin core FR PVC sheathed flat flexible, copper cable etc. as required. | BI01010001010000000000000515BI0100001139 | 6 | each |
| 28 | 28 | CODE NO.3.1: Earthing with G.I.medium pipe 3.0 mt long and 40mm dia including accessories 250 x 50 x 6 mm G.I clamp with 12mm bolt, nut and washer for connecting earth wire, RCC ring enclosure and cover plate complete as required:- | BI01010001010000000000000515BI0100001140 | 3 | Set |
| 29 | 29 | CODE NO.1808: Supplying of 8 SWG copper wire (4.0 mm dia.) suitable for earthing | BI01010001010000000000000515BI0100001141 | 2 | Kg. |
| 30 | 30 | Non-PSR: Fabrication, supply, erection, testing and commissioning of one no of Timer and metering panel board for the power supply of over all size 1100mm x 650mm x 250 mm made out of 16SWG thick cold rolled M.S. Sheet. The front side compartment have energy meter with viewing glass with 10 mm hylem sheet. The back side compartments with 40-63A rating, TPN MCB, \"C Series, 10KA breaking capacity (Make - Siements/ABB), 1 No. of tmier switch (Daily) analog with batery backup to 200 hrs. (Make - L &T. Hagger/ Legrand - Lexic) 1 no. 60A pwer contractor (Make - C&S), 1no of taggle switch (Make - C&S)3nos. of single lamp (Blue, Red, Yellow). (Make - Siemens/C&S/L&T/teknic). The switch units are to be fixed with in the allotted size in the 10mm hylem sheet. The bottom sheet of the shell should be of 16SWG thick cold rolled M.S. sheet with brass gland for cable entry. The panel has to be mounted on the floor with in the height of 375mm. Interior connection between the switch fuse units are to be done with 10.0sqmm ISI marked, FR PVC insulated, single core copper conductor cable (Make -Finolex/Polycab). The door should be of flush type inter locking in one position. The panel provided with removable type gland plated to the bottom and with sufficient holes of required diameter. The panel should be painted with two coats of rust proof Zinc chromate and two coats of anti corrosive epoxy shade 631 siemens grey paint after completion of de-rusting process. Earth work excavation of foundation stench of size 1.00m x 0.45m x 0.60m and filling river sand for a depth of 10 cm and P.C.C, 1:2:4 of size 1.00m x 0.45m x 0.50m. The cost should be inclusive of minor modification suitable for site condition as approved by the Engineer - in - charge. | BI01010001010000000000000515BI0100001142 | 1 | No. |
AI Tender Summary
Tender Timeline
Aug 20, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 28, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender