Providing Sewerage With Primary Treatment Unit For Kala Amb , Moginand Area In Tehsil Nahan Distt . Sirmour Supply And Errection Of Pumping Machinery , Distribution System , Automation , Rcc Ohsr , R/Main And Pump House For Drinking Water Supply Sch, Nahan-Himachal Pradesh

Irrigation And Public Health Department has published Providing Sewerage With Primary Treatment Unit For Kala Amb , Moginand Area In Tehsil Nahan Distt . Sirmour Supply And Errection Of Pumping Machinery , Distribution System , Automation , Rcc Ohsr , R/Main And Pump House For Drinking Water Supply Sch. Submission Date for this Tender is 27-08-2020. Pumping Machiney Tenders in Nahan Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25206720
Providing Sewerage With Primary Treatment Unit For Kala Amb , Moginand Area In Tehsil Nahan Distt . Sirmour Supply And Errection Of Pumping Machinery , Distribution System , Automation , Rcc Ohsr , R/Main And Pump House For Drinking Water Supply Sch
Open Tender
Indian
Himachal Pradesh
Nahan
27-08-2020

Tender Details

Providing Sewerage With Primary Treatment Unit For Kala Amb , Moginand Area In Tehsil Nahan Distt . Sirmour Supply And Errection Of Pumping Machinery , Distribution System , Automation , Rcc Ohsr , R/Main And Pump House For Drinking Water Supply Scheme

Key Value

Document Fees
INR 1500 /-
EMD
INR 179500.0 /-
Tender Value
INR 1.46 Crore /-

BOQ Items

Name of work:- Providing Sewerage with primary treatment unit for Kala Amb, Moginand area in Tehsil Nahan Distt. Sirmour (H.P) (SH:- Supply and errection of Pumping machinery, Distribution system, soft starter, RCC OHSR, R/main and Pump House for drinking water supply scheme). Estimated Cost:- 1,46,67,901/-, E/money:- 1,79,500/-, Time:- 9 Months
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Pumping machinery Moginand
2 1.01 Supply, erection, testing & commissioning of Submersible pumping set of reputed make such as KSB /BS/Johnston/ Worthington / Sabar/ Oswal/Kirloskar/Mather & Platt or any other reputed make,conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characteristics as mentioned in item No.1A) ,greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor.The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- TotalHead:- 237.50 mtrs, Capacity :- 17.034 LPS, Dia of R/main:- 150mm, Length of R/main:- 5180 mtrs, Dia of Column pipe:- 1500, HP:- 2x100HP=20 HP 2 Per Set
3 2 Providing and fixing of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge. 1 Each
4 3 Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No.1(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.The Class of valve shall be ASA-300. 1 Each
5 3.01 Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No.1(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump .The Class of valve shall be ASA-300. 1 Each
6 3.02 Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valveconfirming to API standards with upto date ammendments for Rising Main as mentioned in item No. 1c) for withstanding nominal seat pressure as mentionmed in item No.1(a) + surge pressure.The size of reflux valve shall be equal to the size of Rising main of the same shall be provided with suitable bye pass arrangements. The Class of valve shall be ASA-300 and shall be of 150 mm diameter. 1 Each
7 4 P/L at site of work suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. 1 Per Job
8 4.01 P/L at site PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. 1 Per Job
9 4.02 P/L at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments. 1 Per Job
10 4.03 Supply & errection at site of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T/ /Kilburn /Standard /Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses.(Range to be specified by the tenderer). 1 Each
11 5 Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments. 1 Each
12 6 KALA AMB
13 6.01 Supply, erection, testing & commissioning of Submersible pumping set of reputed make such as KSB /BS/Johnston/ Worthington / Sabar/ Oswal/Kirloskar/Mather & Platt or any other reputed make,conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characteristics as mentioned in item No.6A) ,greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor.The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- Head:- 209.50 mtrs, Capacity:- 12.188 LPS, Dia of R/main:- 150mm, Length of R/main:- 2280 mtrs, Dia of Column pipe:- 150mm, HP:- 2x75=150HP 2 Per Set
14 7 Providing and fixing of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge. 1 Each
15 8 Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No.6(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.The Class of valve shall be ASA-300. 1 Each
16 8.01 Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No.6(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump .The Class of valve shall be ASA-300. 1 Each
17 8.02 Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valveconfirming to API standards with upto date ammendments for Rising Main as mentioned in item No.6 c) for withstanding nominal seat pressure as mentionmed in item No.6 (a) + surge pressure.The size of reflux valve shall be equal to the size of Rising main of the same shall be provided with suitable bye pass arrangements. The Class of valve shall be ASA-300 and shall be of 150 mm diameter. 1 Each
18 9 P/L at site of work suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. 1 Per Job
19 9.02 P/L at site PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. 1 Per Job
20 9.03 P/L at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments. 1 Per Job
21 9.04 Supply & errection at site of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T/ /Kilburn /Standard /Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses.(Range to be specified by the tenderer). 1 Each
22 10 Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments. 1 Each
23 11 Errection of all equipments of both the parts i.e MOGINAND & KALA AMB including cost of tees bends tapers and any other fittings required as per site conditions and as per direction of the Engineer Incharge. 1 Per Job
24 12 Rising Main
25 12.01 Excavation in Drain and Channel in earth work in all kinds of soil Kankar, Moorum, Shingles conglomerate saturated soil decomposed such as containing spade work, , jumper work including decomposed soft and hard rock ,Pucca /metelled /Katcha /concrete/pavers road and paths etc including any hindrences, restoration of cables ,pipe network ,consumer connection /pavers /tiles during day or night with all material all kinds dressing of sides and beds, disposing of excavated earth with all leads,lifts disposal earth to be levelled and neatly dressed and returning the stacked soil into foundation and trenches etc. including ramming and consolidating the same whereever required with all leads ,lifts in cluding jungle clearance , making level with road surface with in all leads, lifts foundation etc.& complete in all respects and as directed by the Engineer Incharge as per CPHEEO mannual. 5054.18 Per Cum
26 13 Laying, , jointing , testing & commissioning at site in trenches following plain ended GMS pipes of various diameters of Heavy/Medium Grade as under confirming to BIS 1239-(Part-1)-1990 or latest with up to date ammendments, capable of withstanding required test pressure as prescribed in BIS code, in randum lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt weld, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable (leak proof) in three layers at site of work with welding rods of standard make & all allied accessories whatever required for welding at site, tail pieces, tees, bends manufactured from parent pipes etc. and cutting of pipes wherever required as per site requirement i/c carriage in all leads & lifts as directed by Engineer-Incharge (Earth work shall be measured & paid for seperately).
27 13.01 S.No R.Ds Nominal Dia Length (in Mtrs)
28 13.02 Moginand
29 13.03 1 0 3360 150mm(H) 3360 3360 Per Rmt
30 13.04 2 3360 5180 150mm(M) 1820 1820 Per Rmt
31 13.05 Kala amb
32 13.06 1 0 2280 150mm(M) 2280 2280 Per Rmt
33 13.07 Distribution
34 13.08 100 mm. Dia (M) 1800 Per Rmt
35 14 Providing, welding and fixing M.S. plate flanges of various diameters (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to MSERW/GI pipes after every 90 metres or as per site requirement including cutting of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect i/c all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
36 14.01 S.No R.Ds Nominal Dia Length (in Mtrs) FT
37 14.02 Moginand
38 14.03 1 0 4320 150mm 4320 FT-17 48 Each Pair
39 14.04 2 4320 5180 150mm 860 FT-5 10 Each Pair
40 14.05 Kala amb
41 14.06 1 0 1440 150mm 1440 FT-17 16 Each Pair
42 14.07 2 1440 2280 150mm 840 FT-5 9 Each Pair
43 15 Distribution System
44 15.01 Laying , jointing, testing & commissioning in trenches following dia socketted galvanised mild steel tube of various dia of LIGHT grade as under confirming to BIS 1239-(Part-1)-1990 or latest with up to date ammendments, capable of with standing required test pressure as BIS code,in randum lengths of 5.5 to 6.5 mtr. The pipe ends shall be socketted ,tees & bends shall be manufactured from parent pipe etc and cutting of pipes whereever required as per stie requirement as per site conditions i/c carriage in all leads & lifts and as directed by Engineer-Incharge.(Earth work shall be measured paid for seperately).
45 15.02 65 mm. Dia 2070 Per Rmt
46 15.03 50 mm. Dia 4600 Per Rmt
47 15.04 40 mm. Dia 1100 Per Rmt
48 16 Providing and fixing brass full way valves with wheel of approved make and relevent ISS complete in all respects including of all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
49 16.01 65 mm. Dia 4 Each
50 16.02 50 mm. Dia 4 Each
51 16.03 40 mm. Dia 14 Each
52 16.04 32 mm. Dia 5 Each
53 17 Construction of chamber1.00x1.00x.9 for the fixing of common head for the operation of Gate Valves compleat with all including ramming and consolidating the same whereever required with all leads, lifts and including jungle clearance and as per the direction of the Engineer Incharge. 8 Each
54 18 OHSR
55 18.01 Construction of Reinforced cement concrete circular Over Head Storage Tank of 300000 litres capacity with 20 meters staging height at MOGINAND complete in all respect as per standard structural drawing and design,approval of the same from competent authority,checking of bearing capacity of soil,all site development and protection works and all construction works of OHSR complete in all respect,inlet,oulets overflow and scour pipe with operating valves,2 Nos. additional outlet pipes for future,warning boards,locking arrangement,linking with pipe network (existing or new),flow meter,sky lightning arrester,painting of pipes with distinct colours,railing,gate,door,chambers,distempering and painting,dome,sensor water level,passages,sign board,capacity of tank,JAL HI JIWAN HAI etc including carriage of material within all leads and lifts as directed by Engineer In charge. 300000 Per Liter
56 19 Construction of Reinforced cement concrete circular Over Head Storage Tank of 200000 litres capacity with 10 meters staging height at KALA AMB complete in all respect as per standard structural drawing and design,approval of the same from competent authority,checking of bearing capacity of soil,all site development and protection works and all construction works of OHSR complete in all respect,inlet,oulets overflow and scour pipe with operating valves,2 Nos. additional outlet pipes for future,warning boards,locking arrangement,linking with pipe network (existing or new),flow meter,sky lightning arrester,painting of pipes with distinct colours,railing,gate,door,chambers,distempering and painting,dome,sensor water level,passages,sign board,capacity of tank,JAL HI JIWAN HAI etc including carriage of material within all leads and lifts as directed by Engineer In charge. 200000 Per Liter
57 20 Pump House 2 Nos ( Moginand and Kala amb.)
58 20.01 Excavation in foundation and trenches etc. in earth work including all kinds of soil such as pick work jumper work,blasting soft and hard rock, conglomirate,upto all leads and lift stacked the excavated soil not more then 3 mtr. Clear from the edge of excavation and then returning the stacked soil in trenches consolidating each deposited layer by ramming and watering and then disposing of all surplus surplus excavted earth as directed by the Engineer-in-Charge 39.22 Per Cum
59 21 Providing and laying cement concrete 1:6:12 (1cement:6sand:12graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth.Including entire carriage of material upto all leads and lifts. 17.12 Per cum
60 22 2nd class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6(1cement:6sand)including entire carriage of material upto all leads and lifts. 21.98 Per cum
61 23 Providing and laying damp proof course 38 mm thick with cement concrete 1:2:4(1cement:2sand :4graded stone aggregate 12.5mm nominal size_) & curing complete.including entire carriage of material upto all leads and lifts 11.44 Per Sqmtr
62 24 Applying a coat of hot bitumen (Maxphalt 80/100 or equivalent)using 1.70m kg/sq. mtr. On damp proof course after cleaning the surface with a piece of cloth lightly soaked with kerosene oil.including entire carriage of materil uopto all leads and lifts. 11.44 Per Sqmtr
63 25 2nd class brick work using common burnt clay building bricks in superstructure in cement mortar 1:6(1cement:6sand)including entire carriage of material upto all leads and lifts. 27.9 Per cum
64 26 Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish including centring & shuttering and propping etc. with wooden batten and ballies,heightof propping and centring below supporting floor to ceiling not exceeding 4mtrs removal of the same for insitu RCC and PCC work in flat surfaces such as sofits,suspended floors.roofs,landing and the like floors etc. 200mm thickness .including entire carriage of material upto all leads and lifts. 54.62 Per Sqmtr
65 27 Providing and laying RCC work 1:2:4(1cement:2 sand:4graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and reinforcement for RCC work in suspended floors,roofs etc. including entire carriage of material upto all leads and lifts. 8.5 Per cum
66 28 Providing and laying tor steel reinforcement for RCC work including bending,winding and placing in position complete upto floor two level.including entire carriage of material upto all leads and lifts. 765 Per Kg
67 29 20 mm cement plaster in single coat on rough side of brick masonary for interior plaster upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth with cement mortar 1:3(1cement:3 sand) including entire carriage of material upto all leads and lifts. 14.46 Per Sqmtr
68 30 15 mm cement plaster in single coat on rough side of brick masonary for interior plaster upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth with cement mortar 1:3(1cement:3 sand) including entire carriage of material upto all leads and lifts. 134.52 Per Sqmtr
69 31 Pointing on brick work with cement mortar 1:3 (1cement:3sand) Ruled pointing including entire carriage of material upto all leads and lifts. 108.6 Per Smtr
70 32 Providing wood work in frame of doors windows and clerestory windows and other frame work wrough framed and fixed in position(2 nd class deodar. Wood). 0.64 Per cum
71 33 Providing fixing panelled glazed or panelled and glazedshutters for doors windows and clerestory window including black enamelled iron butt hinges with necessary screws 40mm thick 2nd class deodar wood.including entire carriage of material upto all leads and lifts. 24.48 Per Sqmtr
72 34 Cement concrete flooring 1:2:4 (1cement:2sand :4graded stone aggregate 20 mm nominal size) laid in one layer finished with floating coat of neat cement 40 mm thick.including entire carriage of material upto all leads and lifts. 43.5 Per cum
73 35 Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil,grease,dirt and other foreign matter .with ready mixed paint brushing wood primer pink.including entire carriage of material upto all leads and lifts. 51.84 Per sqmtr
74 36 Painting two coat excluding priming coat on new wood and wood surfaces with enamel paint to give an even shade including cleaning the surface of dirt,dust and other foreign matter sand papering & stoping.including entire carriage of material upto all leads & lifts 51.84 Per sqmtr
75 37 White washing with lime on decorated wall surfaces(three coats) to give an even shade including throughly brooming the surface to remove all dirt dust mortar drops and loose scale of lime wash and other foreign matter.including entire carriage ofmaterial upto all leads and lifts. 134.52 Per sqmtr
76 38 Construction of stone kharanja drain 45 cm wide in C.M. 1:6(1cement:6sand) including entire carriage of material upto all leads and lifts. 51 Per Rmt
77 39 Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20 mm nominal size)including entire carriage of material upto all leads and lifts. 22.12 Per Sqmtr
78 40 Providing and fixing of 40x3 mm flat iron hold fast 40cms long including fixing to frame with 10mm diameter bolts nuts and wooden plugs and embedding in cement concrete block 30x10x15cms 1:3:6 (1cement:3sandf:6graded stone aggregate 20mm nominal size) including entire carriage of material upto all leads and lifts. 48 Each
79 41 Providing & fixing Aluminium tower bolts barrel type anodized transparent or dyed to required shade and colour with screws etc. complete 250x10 mm 40 Each
80 42 Providing & fixing aluminium handle anodized transparent or dyed to req. shade and colour with screws etc. complete. 125 mm 44 Each
81 43 Providing & fixing sliding door bolts anodized transparent or dyed to required shade and colour with screws etc. complete. 250x16 mm.based surfaces after and including preparing thethe surface by throughly cleaning oil,grease,dirt and other foreign matter .with ready mixed paint brushing wood primer pink.including entire carriage of material upto all leads and lifts. 4 Each
82 44 Providing & fixing electric fitting in pump house including entire carriage of material upto all leads and lifts.with screws etc. complete. 2 Per Job