Repair Of Upswc Godowns At Babrala ( Sambhal )
Tender Value
19.31 Lakhs
Estimated cost
Bid Submission
31 Aug 2020
0 days left
EMD
38700
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Babrala(Sambhal) → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair Of Upswc Godowns At Babrala ( Sambhal )
BOQ
| Name of Work: Repair of Boundrywall,Godown & Construction of Toilets etc at Babrala(Sambhal) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Repair of Boundrywall | BI01010001010000000000000515BI0100001150 | ||
| 2 | 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar | BI01010001010000000000000515BI0100001151 | 22.86 | cum |
| 3 | 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. | BI01010001010000000000000515BI0100001152 | 48.39 | cum |
| 4 | 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001153 | 4.02 | cum |
| 5 | 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001154 | 8.65 | cum |
| 6 | 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001155 | 2.43 | cum |
| 7 | 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars | BI01010001010000000000000515BI0100001156 | 954.57 | Kg |
| 8 | 8 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete | BI01010001010000000000000515BI0100001157 | 42.19 | sqm |
| 9 | 9 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Shelves (Cast in situ) | BI01010001010000000000000515BI0100001158 | 2.43 | sqm |
| 10 | 10 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Lintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001159 | 30.4 | sqm |
| 11 | 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001160 | 22.09 | cum |
| 12 | 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001161 | 21.86 | cum |
| 13 | 13 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001162 | 280 | sqm |
| 14 | 14 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured):From brick work in cement mortar | BI01010001010000000000000515BI0100001163 | 5258 | 1000 Nos |
| 15 | 15 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. | BI01010001010000000000000515BI0100001164 | 59.98 | kg |
| 16 | 16 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work | BI01010001010000000000000515BI0100001165 | 280 | sqm |
| 17 | 17 | Repair of gate. | BI01010001010000000000000515BI0100001166 | 1 | Nos |
| 18 | 18 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work | BI01010001010000000000000515BI0100001167 | 10.8 | sqm |
| 19 | 19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001168 | 4.6 | cum |
| 20 | 20 | Repair of Godown | BI01010001010000000000000515BI0100001169 | ||
| 21 | 21 | Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. | BI01010001010000000000000515BI0100001170 | 935.68 | kg |
| 22 | 22 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:Asbestos cement sheet | BI01010001010000000000000515BI0100001171 | 425.25 | sqm |
| 23 | 23 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. | BI01010001010000000000000515BI0100001172 | 200 | Kg |
| 24 | 24 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar | BI01010001010000000000000515BI0100001173 | 6.5 | cum |
| 25 | 25 | Refix of Truss | BI01010001010000000000000515BI0100001174 | 200 | Kg |
| 26 | 26 | Repair of rolling shutter i/e washing of Shutter by kerosin oil, oiling gressing and tighting of spring, T & P etc Complete & as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001175 | 52 | Nos |
| 27 | 27 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. | BI01010001010000000000000515BI0100001176 | 434.7 | sqm |
| 28 | 28 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete.Close fitting adjustable ridges | BI01010001010000000000000515BI0100001177 | 40 | metre |
| 29 | 29 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001178 | 6.5 | cum |
| 30 | 30 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001179 | 332.48 | sqm |
| 31 | 31 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work | BI01010001010000000000000515BI0100001180 | 332.48 | sqm |
| 32 | 32 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m² | BI01010001010000000000000515BI0100001181 | 317.75 | metre |
| 33 | 33 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | BI01010001010000000000000515BI0100001182 | 204.88 | sqm |
| 34 | 34 | Refixing of old wind tie.as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001183 | 511.3 | metre |
| 35 | 35 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase | BI01010001010000000000000515BI0100001184 | 283.45 | metre |
| 36 | 36 | Supply & Fixing Submersible Pump 0.75H.P approved Quality Varuna or C.R.B. including boring and all complete 200 metre deep & as per direction of Engineer in- charge | BI01010001010000000000000515BI0100001185 | 1 | Job |
| 37 | 37 | Construction of Toilet | BI01010001010000000000000515BI0100001186 | ||
| 38 | 38 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. | BI01010001010000000000000515BI0100001187 | 13.27 | cum |
| 39 | 39 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001188 | 4.1 | cum |
| 40 | 40 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001189 | 10.7 | cum |
| 41 | 41 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | BI01010001010000000000000515BI0100001190 | 6.63 | cum |
| 42 | 42 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) | BI01010001010000000000000515BI0100001191 | 4.99 | sqm |
| 43 | 43 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001192 | 7.63 | cum |
| 44 | 44 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001193 | 2.25 | cum |
| 45 | 45 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001194 | 5.05 | sqm |
| 46 | 46 | Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001195 | 16.63 | sqm |
| 47 | 47 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars | BI01010001010000000000000515BI0100001196 | 221.33 | Kg |
| 48 | 48 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001197 | 0.32 | cum |
| 49 | 49 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001198 | 21.83 | sqm |
| 50 | 50 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. | BI01010001010000000000000515BI0100001199 | 5.78 | sqm |
| 51 | 51 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001200 | 60.74 | sqm |
| 52 | 52 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer | BI01010001010000000000000515BI0100001201 | 19.96 | sqm |
| 53 | 53 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. | BI01010001010000000000000515BI0100001202 | 52.1 | sqm |
| 54 | 54 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate | BI01010001010000000000000515BI0100001203 | 12.79 | sqm |
| 55 | 55 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws | BI01010001010000000000000515BI0100001204 | 3 | sqm |
| 56 | 56 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | BI01010001010000000000000515BI0100001205 | 71 | kg |
| 57 | 57 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | BI01010001010000000000000515BI0100001206 | 6.27 | sqm |
| 58 | 58 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | BI01010001010000000000000515BI0100001207 | 1 | each |
| 59 | 59 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern | BI01010001010000000000000515BI0100001208 | 2 | each |
| 60 | 60 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | BI01010001010000000000000515BI0100001209 | 1 | each |
| 61 | 61 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. | BI01010001010000000000000515BI0100001210 | 200 | per litre |
| 62 | 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001211 | 25 | metre |
| 63 | 63 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001212 | 15 | metre |
| 64 | 64 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore | BI01010001010000000000000515BI0100001213 | 3 | each |
| 65 | 65 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia | BI01010001010000000000000515BI0100001214 | 2 | each |
| 66 | 66 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore | BI01010001010000000000000515BI0100001215 | 4 | each |
| 67 | 67 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore | BI01010001010000000000000515BI0100001216 | 1 | each |
| 68 | 68 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore | BI01010001010000000000000515BI0100001217 | 4 | each |
| 69 | 69 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) | BI01010001010000000000000515BI0100001218 | 15.93 | sqm |
| 70 | 70 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter | BI01010001010000000000000515BI0100001219 | 20 | metre |
| 71 | 71 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter | BI01010001010000000000000515BI0100001220 | 3 | metre |
| 72 | 72 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001221 | 28 | kg |
| 73 | 73 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | BI01010001010000000000000515BI0100001222 | 9.21 | sqm |
| 74 | 74 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks:1:6 (1cement : 6 coarse sand) | BI01010001010000000000000515BI0100001223 | 20 | sqm |
AI Tender Summary
Tender Timeline
Aug 13, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 31, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender