Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 0 days TDR #25159943

Supply Of Field Instruments – Transmitters (P, Dp, F, L, T, Td) – Lot-2

Issued by Boards / Undertakings / PSU · IOCL GUJARAT IOCLGUJARAT, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Sep 2020
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Auction
Location / State
IOCL GUJARAT IOCLGUJARAT → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Field Instruments – Transmitters ( P, Dp, F, L, T, Td ) – Lot-2:-1 Flow Transmitters - Total Qty: 13 Nos. ( Line Item 1.1 & 1.13 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 2 Sensor Material: Ss316 ( As Min ) , Range: 0-95 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter N 3 Sensor Material: Gold Plated Monel, Range: 0-48000 Nm3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter N 4 Sensor Material: Gold Plated Monel, Range: 0-48000 Nm3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter N 5 Sensor Material: Gold Plated Monel, Range: 0-48000 Nm3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter N 6 Sensor Material: Gold Plated Monel, Range: 0-1100 Nm3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 7 Sensor Material: Gold Plated Monel, Range: 0-0.8 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 8 Sensor Material: Ss316l ( As Min. ) , Range: 0-5 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 9 Sensor Material: Ss316l ( As Min. ) , Range: 0-5 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 10 Sensor Material: Ss316l ( As Min. ) , Range: 0-5 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 11 Sensor Material: Ss316l ( As Min. ) , Range: 0-5 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 12 Sensor Material: Ss316 ( As Min. ) , Range: 0-4 M3 / H, Dp @ Full Scale: 1250 Mmh2o, With Kidney Flange Adapter 13 Sensor Material: Ss316, Range: 0-20 Nm3 / H, Dp @ Full Scale: 1250 Mmh2o, With 3-Way Manifold 14 Sensor Material: Ss316, Range: 0-75 Nm3 / H, Dp @ Full Scale: 1250 Mmh2o, With 3-Way Manifold 15 Integral Orifice Meter Run - Total Qty: 03 Nos. ( Line Item 2.1 & 2.3 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 16 Integral Orifice Meter Run With Flanges - 1 Rf / 300#, 125 Aarh, Plate Moc:Monel 17 Integral Orifice Meter Run With Flanges – 1”, Rf / 150#, 125 Aarh, Plate Moc: Ss316 18 Integral Orifice Meter Run With Flanges – 1”, Rf / 150#, 125 Aarh, Plate Moc: Ss316. 19 Diffrential Level Transmitters - Total Qty: 1 No . ( Line Item 3.1 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 20 3”, Rf / 300#, 125 Aarh, Sensor Material: Ss316 ( As Min. ) , Range: 0-1510 Mmh2o, With Seal 21 Electronic Indicator - Total Qty: 2 No . ( Line Item 4.1 & 4.2 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 22 Local Electronic Indicator, Smart With Lcd Display 23 Local Electronic Indicator, Smart With Lcd Display 24 Pressure Transmitters - Total Qty: 03 Nos. ( From Line Item 5.1 To 5.3 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 25 Sensor Material : Gold Plated Monel, Range: 70-110 Kgf / Cm²-G, With Kidney Flange Adapter 26 Sensor Material : Gold Plated Monel, Range: 70-110 Kgf / Cm²-G, With Kidney Flange Adapter 27 Sensor Material : Gold Plated Monel, Range: 70-110 Kgf / Cm²-G, With Kidney Flange Adapter 28 Temperature Transmitters - Total Qty: 01 No. ( From Line Item 6.1 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 29 Temperature Transmitters: Range: 130-230 °C

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 28-Aug-2020 Commercial Corrigendum-1 Date 04-Sep-2020

BOQ

Name of Work: Supply of Field Instruments – Transmitters (P, DP, F, L, T, TD) – Lot-2
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Flow Transmitters - Total QTY: 13 Nos. (Line item 1.1 & 1.13), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
21.01Sensor Material: SS316 (as min), Range: 0-95 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter\nitem11No
31.02Sensor Material: GOLD PLATED MONEL, Range: 0-48000 Nm3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter \nitem21No
41.03Sensor Material: GOLD PLATED MONEL, Range: 0-48000 Nm3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter \nitem31No
51.04Sensor Material: GOLD PLATED MONEL, Range: 0-48000 Nm3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter \nitem41No
61.05Sensor Material: GOLD PLATED MONEL, Range: 0-1100 Nm3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapteritem51No
71.06Sensor Material: GOLD PLATED MONEL, Range: 0-0.8 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapteritem61No
81.07Sensor Material: SS316L (as min.), Range: 0-5 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapteritem71No
91.08Sensor Material: SS316L (as min.), Range: 0-5 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapteritem81No
101.09Sensor Material: SS316L (as min.), Range: 0-5 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapteritem91No
111.1Sensor Material: SS316L (as min.), Range: 0-5 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapteritem101No
121.11Sensor Material: SS316 (as min.), Range: 0-4 m3/h, DP @ Full Scale: 1250 mmH2O, With Kidney Flange Adapteritem111No
131.12Sensor Material: SS316, Range: 0-20 Nm3/h, DP @ Full Scale: 1250 mmH2O, With 3-Way Manifolditem121No
141.13Sensor Material: SS316, Range: 0-75 Nm3/h, DP @ Full Scale: 1250 mmH2O, With 3-Way Manifolditem131No
152Integral Orifice Meter Run - Total QTY: 03 Nos. (Line item 2.1 & 2.3), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
162.01Integral Orifice Meter Run with flanges - 1\" RF/300#, 125 AARH, Plate MOC:MONELitem141No
172.02Integral Orifice Meter Run with flanges – 1”, RF/150#, 125 AARH, Plate MOC: SS316item151No
182.03Integral Orifice Meter Run with flanges – 1”, RF/150#, 125 AARH, Plate MOC: SS316.item161No
193Diffrential Level Transmitters - Total QTY: 1 No . (Line item 3.1), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
203.013”, RF/300#, 125 AARH, Sensor Material: SS316 (as min.), Range: 0-1510 mmH2O, With Sealitem171No
214Electronic Indicator - Total QTY: 2 No . (Line item 4.1 & 4.2), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
224.01Local Electronic Indicator, SMART with LCD Displayitem181No
234.02Local Electronic Indicator, SMART with LCD Displayitem191No
245Pressure Transmitters - Total QTY: 03 Nos. (from line item 5.1 to 5.3), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
255.01Sensor Material : GOLD PLATED MONEL, Range: 70-110 kgf/cm²-g, With Kidney Flange Adapteritem201No
265.02Sensor Material : GOLD PLATED MONEL, Range: 70-110 kgf/cm²-g, With Kidney Flange Adapteritem211No
275.03Sensor Material : GOLD PLATED MONEL, Range: 70-110 kgf/cm²-g, With Kidney Flange Adapteritem221No
286Temperature Transmitters - Total QTY: 01 No. (from line item 6.1), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
296.01Temperature Transmitters: Range: 130-230 °Citem231No

AI Tender Summary

OUR REF NO 25159943
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 04-09-2020
Authority
Authority Name Indian Oil Corporation Limited
Work Description Supply Of Field Instruments – Transmitters ( P, Dp, F, L, T, Td ) – Lot-2:-1 Flow Transmitters - Total Qty: 13 Nos. ( Line Item 1.1 & 1.13 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 2 Sensor Material: Ss316 ( As Min ) , Range: 0-95 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter N 3 Sensor Material: Gold Plated Monel, Range: 0-48000 Nm3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter N 4 Sensor Material: Gold Plated Monel, Range: 0-48000 Nm3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter N 5 Sensor Material: Gold Plated Monel, Range: 0-48000 Nm3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter N 6 Sensor Material: Gold Plated Monel, Range: 0-1100 Nm3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 7 Sensor Material: Gold Plated Monel, Range: 0-0.8 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 8 Sensor Material: Ss316l ( As Min. ) , Range: 0-5 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 9 Sensor Material: Ss316l ( As Min. ) , Range: 0-5 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 10 Sensor Material: Ss316l ( As Min. ) , Range: 0-5 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 11 Sensor Material: Ss316l ( As Min. ) , Range: 0-5 M3 / H, Dp @ Full Scale: 2500 Mmh2o, With Kidney Flange Adapter 12 Sensor Material: Ss316 ( As Min. ) , Range: 0-4 M3 / H, Dp @ Full Scale: 1250 Mmh2o, With Kidney Flange Adapter 13 Sensor Material: Ss316, Range: 0-20 Nm3 / H, Dp @ Full Scale: 1250 Mmh2o, With 3-Way Manifold 14 Sensor Material: Ss316, Range: 0-75 Nm3 / H, Dp @ Full Scale: 1250 Mmh2o, With 3-Way Manifold 15 Integral Orifice Meter Run - Total Qty: 03 Nos. ( Line Item 2.1 & 2.3 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 16 Integral Orifice Meter Run With Flanges - 1 Rf / 300#, 125 Aarh, Plate Moc:Monel 17 Integral Orifice Meter Run With Flanges – 1”, Rf / 150#, 125 Aarh, Plate Moc: Ss316 18 Integral Orifice Meter Run With Flanges – 1”, Rf / 150#, 125 Aarh, Plate Moc: Ss316. 19 Diffrential Level Transmitters - Total Qty: 1 No . ( Line Item 3.1 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 20 3”, Rf / 300#, 125 Aarh, Sensor Material: Ss316 ( As Min. ) , Range: 0-1510 Mmh2o, With Seal 21 Electronic Indicator - Total Qty: 2 No . ( Line Item 4.1 & 4.2 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 22 Local Electronic Indicator, Smart With Lcd Display 23 Local Electronic Indicator, Smart With Lcd Display 24 Pressure Transmitters - Total Qty: 03 Nos. ( From Line Item 5.1 To 5.3 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 25 Sensor Material : Gold Plated Monel, Range: 70-110 Kgf / Cm²-G, With Kidney Flange Adapter 26 Sensor Material : Gold Plated Monel, Range: 70-110 Kgf / Cm²-G, With Kidney Flange Adapter 27 Sensor Material : Gold Plated Monel, Range: 70-110 Kgf / Cm²-G, With Kidney Flange Adapter 28 Temperature Transmitters - Total Qty: 01 No. ( From Line Item 6.1 ) , Refer Doc. No. 44Ad0600-00 / J.04 / 0243 For Datasheets 29 Temperature Transmitters: Range: 130-230 °C
Basic Detail
Tender No 44AD0600-ER-64-0243
Bidding Type Auction
Location
City IOCL GUJARAT IOCLGUJARAT
State Gujarat
Key Dates
Publish Date 28 Aug 2020
Submission Date 04 Sep 2020
Open Date 07 Sep 2020
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
FAQs-IOCL-Online-EMD.pdf
Tender-Acceptance-Format.pdf
BOQ_131999.xls
Tendernotice_1.pdf
III.pdf
Special_Instructions_to_the_Bidders_20200717.pdf
8F692079-E85C-4A5C-919D-D4DB1F812791.html
PARTI.rar

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 28, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 04, 2020
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 04, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 07, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

FAQs-IOCL-Online-EMD.pdf

pdf

Tender-Acceptance-Format.pdf

xls

BOQ_131999.xls

pdf

Tendernotice_1.pdf

pdf

III.pdf

pdf

Special_Instructions_to_the_Bidders_20200717.pdf

html

8F692079-E85C-4A5C-919D-D4DB1F812791.html

rar

PARTI.rar

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders