Sales : +91-777 804 8217
| Name of Work: PROVISION OF CERTAIN INFRASTRUCTURE AT PIR BHADRESHWAR , BIMBER GALLI AND OTHER LOCATIONS UNDER GE AF JAMMU | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Excavating over area, not exceeding 1.5 m deep and getting out in any type of soil complete all as specified and directed. | 442 | CUM | |
| 2 | 2 | Excavating over area, not exceeding 1.5 m deep and getting out in soft,disintegrated rocks complete all as specified and directed.. | 227 | Cum | |
| 3 | 3 | Excavating over area, not exceeding1.5 m deep and getting out in hard rocks complete all as specified and directed. | 100 | Cum | |
| 4 | 4 | Excavation in trenches not exceeding 1.5 m in width and not exceeding1.5 m deep and getting out in hard/dense soil complete all as specified and directed. | 330.85 | Cum | |
| 5 | 5 | Returning filling in including spreading, levelling, watering and well ramming in layers n. exc. 25 cm in soils complete all as and directed. | 279 | Cum | |
| 6 | 6 | Removing excavated material (Soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point to entire satisfaction of Engineer-in-Charge complete all as specified and directed . | 687.4 | Cum | |
| 7 | 7 | Removing excavated material (Rocks) to a distance exceeding 250 m but not exceeding 500 m and depositing where directed at a level not exceeding 1.5m above the starting point to entire satisfaction of Engineer-in-Charge complete all as specified and directed . | 877 | Cum | |
| 8 | 8 | PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in filling, foundation and mass concrete complete al las specified and directed. | 32.52 | Cum | |
| 9 | 9 | Mild steel TMT bars 10mm dia and over in reinforcement , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. | 40000 | Kg | |
| 10 | 10 | Mild steel TMT bars 5mm dia and over up to and including 10 mm dia as in stirrups and spacers in reinforcement , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.. | 1500 | Kg | |
| 11 | 11 | Form work to sofit of suspended slab such as roof slab not exceeding 200 mm thick horizontal or sloping including fair finished to concrete surfaces complete all as specified and directed.. | 150 | Sqm | |
| 12 | 12 | Formwork to sides of concrete foundation,bases of coloumns,raft beams,sides and sofit (if any) of foundation and plinth beams and similier work; etc vertical or batter rough finished surface of concrete complete all as specified and directed.. | 391 | Sqm | |
| 13 | 13 | Form work to faces of walls, retaining walls,abitments,parapets and staircase railling and similiar work including attached pillerstears,buttress, etc rough finished surface of concrete complete all as specified and directed.. | 1200 | Sqm | |
| 14 | 14 | Form work to staircase with sloping or stepped sofits including risers and stringers rough finished surface of concerte ( excluding landing ) complete all as specified and directed.. | 120 | Sqm | |
| 15 | 15 | Form work to edges of concrete not exceeding 20cm wide rough finished surface of concerte complete all as specified and directed.. | 150 | Sqm | |
| 16 | 16 | RCC M-25 (Design mix) as in Roof slab, shelves, landing slab supported on wall/column and the like etc complete all as specified and directed. | 57.09 | Cum | |
| 17 | 17 | RCC M 25 Design mix as in retaining walls, basement walls and the like any thickness above top of footing including attached pilasters and butresses complete all as specified and directed. | 230 | Cum | |
| 18 | 18 | Rolled mild steel section as in joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e within 20mm of the length indicated conforming to Fe 410-W (Gde-E- 250)quality-B complete all as specified and directed.. | 1500 | Kg | |
| 19 | 19 | Mild Steel Framed work as in door or gates of angle or other section with guesst plates,rails,braces, etc. complete drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including eithers hooks and hinges or steel hanging door fitting and also hanging and fasting fixing complete (12 mm thick sheet ) conforming to Fe 410-W (Gde-E- 250)quality-B complete all as specified and directed.. | 2000 | Kg | |
| 20 | 20 | Mild steel Framed work such as arnomental steel gates, braces, rails, gusset plates , including hold fasts welding, rivetting and similar work conforming to Fe-290 Gde E 165 complete all as specified and directed.. | 400 | Kg | |
| 21 | 21 | 18 mm plywood, grade BWP, type BB fixed with screws to timber frame work complete all as specified and directed . | 89.9 | Sqm | |
| 22 | 22 | Plain, black mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) as in roof bottom.(1.25mm thick) complete all as specified and directed.. | 26.9 | Sqm | |
| 23 | 23 | 100 mm thick PCC 1:4:8 type D 2 using 20 mm graded crushed stone aggregate as in floor sub base complete all as specified and directed... | 345.77 | Sqm | |
| 24 | 24 | RCC type B1 1:2:4, using 20 mm graded crushed stone aggregate (nominal mix) as in lintel beam/band etc complete all as specified and directed. | 2 | Cum | |
| 25 | 25 | Supply only integral water profing compound ISI marked complete all as specified and directed.. . | 20 | Kg | |
| 26 | 26 | 40mm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate in floors including finishing cement concrete surface even and smooth with using extra cement complete all as specified and directed... | 129.77 | Sqm | |
| 27 | 27 | Non - skid Ceramic tiles 7 to 8 mm thick joint free coloured tiles area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over and including Screed bed or bedding layer of mortar 15 mm thick in Cement mortor 1:6 for laying floor finishes complete all as specified and directed. | 7.5 | Sqm | |
| 28 | 28 | Glazed ceramic coloured joint free tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including Screed bed or bedding layer of mortar 10 mm thick in Cement mortor 1:4 for laying floor finishes complete all as specified and directed... | 51.09 | Sqm | |
| 29 | 29 | Brick work with sub class ' B ' bricks straight or curved on plan exc 6 m mean radium built in cement mortar 1:6 complete all as specified and directed.. | 50 | Cum | |
| 30 | 30 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 on external surfaces complete all as specified and directed.. | 1190 | Sqm | |
| 31 | 31 | Solid PVC Frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling &fixing in opening as per spcification &drawing Note:- i) Existing wall edges will have to be finished properly in cement plaster 1:4 . including fixing of 6 Nos wooden plugs for catch door frame size not exc 17 Sqcm average sectional areas and 100mm long. (ii) Frame will have to be fixed to the wooden plugs inserted in wall using 6 Nos of 100mm long MS screw, 3 each on either side. (iii) PCC strip of section 5.5mm will have to be created at bottom incl. smooth finish in each door opening. | 30 | RM | |
| 32 | 32 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S frame shall be top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC `C`channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stile & rail with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed..\n | 11.63 | Sqm | |
| 33 | 33 | Butt hinges 100mm, stainless steel hinge pin, anodised and fixed, type C-12 complete all as specified and directed.. | 45 | Each | |
| 34 | 34 | Aluminium anodised barrel tower bolts of extruded section 200mm size complete all as specified and directed. | 30 | Each | |
| 35 | 35 | Extruded Aluminium alloy handles fabricated type anodised 150mm long complete all as specified and directed... | 30 | Each | |
| 36 | 36 | Mild Steel Tubes 15 mm bore , medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. | 45 | RM | |
| 37 | 37 | Mild Steel Tubes 20 mm bore , medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. | 30 | RM | |
| 38 | 38 | PVC valveless, syphonic action type, flushing cistern, low level white, with inlet ball valve, float and handle including brackets of 10 litrs capacity complete all as specified and directed. | 3 | Each | |
| 39 | 39 | Bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe, 15 mm bore complete all as specified and directed. | 9 | Each | |
| 40 | 40 | Stop valves fancy chromium plated, cast copper alloy, screwed down, high pressure and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and directed. | 6 | Each | |
| 41 | 41 | PVC connection 15 mm size 450 mm long with brass nuts on either sides complete all as specified and directed. . | 6 | Each | |
| 42 | 42 | Vitreous china wash hand basin, white flat back size 550x400mm (excluding taps, waste, pipe chain and plug) but including porcelain stopper and a pair of MS bracket etc complete all as specified and directed. | 3 | Each | |
| 43 | 43 | Piller taps 15 mm dia cost copper alloy with capstan head , screwed down Cp with high pressure with or with out lettered Hot or Cold with long screwed for iron pipe and fixed complete all as specified and directed. | 3 | Each | |
| 44 | 44 | Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed. | 3 | Each | |
| 45 | 45 | PVC (SWR) bend 75mm dia complete all as specified and directed. . | 3 | Each | |
| 46 | 46 | PVC (SWR) floor trap with grating including jointing to solvent cement wast pipe75 mm dia complete all as specified and directed. . | 3 | Each | |
| 47 | 47 | Looking mirror size 600x450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. . | 3 | Each | |
| 48 | 48 | Towel rail 600mm long 20mm dia aluminium anodised chromium plated fixed with wooden guities embeded in cement mortar (1 : 3) with steel screws etccomplete all as specified and directed. | 3 | Each | |
| 49 | 49 | Vitreous China wash down water closet pan (pedestal pattern), white ( excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. | 3 | Each | |
| 50 | 50 | 1000 Ltr capacity Rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. | 3 | Each | |
| 51 | 51 | PCC 1:3:6 type C 1 using 20 mm graded crushed stone aggregate, as in plinth protection 75mm thick finished even and fair including necessary form work complete all as specified and directed. | 197 | Sqm | |
| 52 | 52 | Two coats of synthetic enamel paint over one coat of red oxide primer on new steel surfaces over 10 cm in width or grith not other wise describedcomplete all as specified and directed. | 60 | Sqm | |
| 53 | 53 | Preparation of plastered surfaces of ceiling and applying three coats of white wash on new surfaces complete all as specified and directed. . | 240 | Sqm | |
| 54 | 54 | Preparation of new plastered surfaces and applying two coat of oil bound distermper over a coat of chalk whitening on walls complete all as specified and directed. | 769 | Sqm | |
| 55 | 55 | Applying two coats of weather proof exterior emulsion (water based) paint in camoflage pattern of dark colour / shade on walls (shade to approved by GE) complete all as specified and directed. | 384 | Sqm | |
| 56 | 56 | Rough excavation not exceeding 1.5 Metre deep and getting out in hard/dence soil complete all as specified and directed. | 200 | Cum | |
| 57 | 57 | Rough excavation depth exceeding 1.5 Metre but not exceeding 3.0 Metre deep and getting out in hard/dence soil complete all as specified and directed. | 50 | Cum | |
| 58 | 58 | Rough excavation not exceeding 1.5 Metre deep and getting out in soft/disintegrated rock complete all as specified and directed. | 300 | Cum | |
| 59 | 59 | Rough excavation depth exceeding 1.5 Metre but not exceeding 3.0 Metre deep and getting out in soft/disintegrated rock complete all as specified and directed. | 50 | Cum | |
| 60 | 60 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and directed. | 216 | Sqm | |
| 61 | 61 | 75 mm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate as in paths complete all as specified and directed. | 216 | Sqm | |
| 62 | 62 | Reinforced concrete pipes 150mm bore, class NP3 with one collar per length of pipe laid and jointed on concrete bed , complete all as specified and as directed. | 70 | RM | |
| 63 | 63 | Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 for manhole and external pointed flush in same mortar as the work proceeds, complete all as specified and directed. | 3 | Cum | |
| 64 | 64 | PCC 1:2:4 type B1, using 20 mm graded crushed stone aggregate as in benching to drain including weathering slightly rounded or chamfered angles complete all as specified and directed. | 1.5 | Cum | |
| 65 | 65 | Rendering 15mm thick in CM 1:4 on brick work of concrete surgaces mixed with integral water proofing compound finished fair and finish without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid seperately. | 43 | Sqm | |
| 66 | 66 | Supply only integral water profing compound ISI marked complete all as specified and directed . | 13 | Kg | |
| 67 | 67 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends complete all as specified and directed. | 44.5 | RM | |
| 68 | 68 | Add or deduct for each 25mm girth or part thereof over or under 30 cm as in Item No 67 above. | 40 | RM | |
| 69 | 69 | 25 user septic tank On site LLDPE Septic tank designed to carry sewage and sullage water,excavation in any type of soil , PCC (1:4:8 type D2) below foundation ,Vent shaft,connection etc complete all as specified and directed | 3 | Each | |
| 70 | 70 | .Soakage wells including excavation in ordinary soil, foundation in PCC 1:3:6 wells of honey combed and solid including intercepting chamber,screen chamber in CH,RCC cover, slab in RCC 1:2:4 Type B-I Masonary/filling with brick bats complete of size 1.80m diax3m deep from inlet pipe and complete as shown on drawings. | 3 | Each | |
| 71 | 71 | PCC 1:3:6 type C 1 using 20 mm graded crushed stone aggregate, as in wall any thickness size or shape including pilasters, buttresses coloumns,pillers,boundry pillers and post ( including caps and bases) complete all as specified and directed | 14 | Cum | |
| 72 | 72 | PCC 1:3:6 type C 1 using 20 mm graded crushed stone aggregate, as in surface channels and drains complete all as specified and directed. | 2 | Cum | |
| 73 | 73 | Point wiring with 1.5 Sqmm single core multi stranded copper conductor FR-PVC insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FR-PVC insulated drawn into and including PVC casing and capping ISI marked terminated into PVC terminal boxes including 3.00 mm thick PVC sheet , PVC laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed by the Engr-in-Charge for One light/fan point controlled by one way switch 5 Amp complete all as specified and directed | 102 | Per point | |
| 74 | 74 | Point wiring with 1.5 Sqmm single core multi stranded copper conductor FR-PVC insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FR-PVC insulated drawn into and including PVC casing and capping ISI marked terminated into PVC terminal boxes including 3.00 mm thick PVC sheet , PVC laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed by the Engr-in-Charge for for one 3 pin socket outlet 5 Amp independent complete all as specified and directed | 24 | Per point | |
| 75 | 75 | Point wiring with 2.5 Sqmm single core multi stranded copper conductor FR-PVC insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 2.5 sqmm copper conductor flexible FR-PVC insulated drawn into and including PVC casing and capping ISI marked terminated into PVC terminal boxes including 3.00 mm thick PVC sheet , PVC laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed by the Engr-in-Charge for for one 3 pin socket outlet 15 Amp independent complete all as specified and directed | 12 | Per point | |
| 76 | 76 | Switch piano flush button single pole one way 5 Amp 240 Volts complete all as specified and directed. | 126 | Each | |
| 77 | 77 | Switch piano flush button single pole one way 15 Amp 240 Volts complete all as specified and directed. | 12 | Each | |
| 78 | 78 | Socket outlet 2 in 1, 2 and 3 pin 5 Amp piano flush type 240 volts complete all as specified and directed | 24 | Each | |
| 79 | 79 | Socket outlet 2 in 1, 3 pin 5 Amp and 15 Amp piano flush type 240 voltscomplete all as specified and directed | 12 | Each | |
| 80 | 80 | Ceiling rose 3 Phase PVC/ Polycarbonae three terminal complete all as specified and directed | 66 | Each | |
| 81 | 81 | Surface and wall mounted LED batten of 18 Watt with polycarbonate housing and integrated driver complete prewired with copper cable multistranded single core 1.5 sqmm for electric connection complete all as specified and directed | 42 | Each | |
| 82 | 82 | Angle holder PVC insulated with back plate suitable for batten fitting complete all as specified and as directed | 36 | Each | |
| 83 | 83 | LED lamp 12 watt normal holder type complete all as specified and directed | 36 | Each | |
| 84 | 84 | Electronic fan regulator step type flush type suitable for 1200 / 1400 mm sweep AC Ceiling fan complete all as specified and directed. | 18 | Each | |
| 85 | 85 | Ceiling fan 1200 mm sweep copper wound with all accessories such as hanging rod, clamps, capacitor, covers etc complete all as specified and directed\n | 18 | Each | |
| 86 | 86 | Exhaust fan heavy duty 300 mm sweep copper wound with all accessories such as louvers nuts, bolts and washer including drilling holes and providing gutties and screw complete all as required at site for fixing fan complete all as specified and directed.\n | 6 | Each | |
| 87 | 87 | Supply , testing and Installing the electric water heater storage type 25 Ltr capacity 5 star rated of vertical type and having the wall mounting arrangement, thermostat, indicators and thermally insulated copper tank of glass lined inside the tank and heating element and fixing nut bolts will be grouted on wall suitable size complete all as specified and directed.\n. | 6 | Each | |
| 88 | 88 | Distribution board sheet steel phosphated powder painted for MCB / DB with copper bus bar and neutral link earthing stud (confirming to IS - 13032, IS - 8623) SPN 8 Way 240 Volts double door complete all as specified and directed | 6 | Each | |
| 89 | 89 | Distribution board sheet steel phosphated powder painted for MCB / DB with copper bus bar and neutral link earthing stud (confirming to IS - 13032, IS - 8623) SPN 4 Way 240 Volts double door complete all as specified and directed | 3 | Each | |
| 90 | 90 | MCB single pole and neutral 240 volts, 50 Hz of rating 32 amps, with rupturing capacity 10 KA `C' series including providing thimble for cables complete all as specified and directed. \n | 9 | Each | |
| 91 | 91 | MCB single pole 240 volts, 50 Hz of rating 06 to 32 Amps, with rupturing capacity 10 KA `C' series including providing thimble for cables complete all as specified and directed. \n | 39 | Each | |
| 92 | 92 | Flame Proof Point Wiring in concealed ERW Steel conduit using stranded copper conductor cable of size 1.5 Sqmm PVC insulated usheathed FRHR cable complete with all fittings and accessories and 1.5 sqmm PVC insulated stranded copper conductor FRHR cable as continues earth wire connected to common earth dolly all as directed and as specified for One light/fan point controlled by one way switch 5 Amp complete all as specified and directed. | 6 | Per Point | |
| 93 | 93 | Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed | 6 | Each | |
| 94 | 94 | LED Flameproof light fitting (T8 fitting) 1 x 16/20 Watt complete with all accessories including connecting up with twin core twisted flexible copper conductor complete all as specified and directed .\n | 6 | Each | |
| 95 | 95 | Earthing complete with Galvanised steel earth plate electrode, 600 mm x 600 mm x 6 mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below ground level connected to Galvanised Earth Lead Wire of size 4.00 mm dia by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, alternate layer of charcoal and salt, 40mm thick pre-cast PCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed.\nNotes: \n1. Earth lead & protection pipes length upto & including 7.50 metre.\n2. Earth filling shall be done by vegitable soil.\n3. Soil should be free from stone, boulders, aggregate, gravels etc. | 9 | Each | |
| 96 | 96 | Air termination rod , single pointed , Aluminium rod having 12 mm dia and 300 mm long complete all as specified and directed . | 129 | Each | |
| 97 | 97 | GI pipe, medium grade 15 mm dia bore for installation of air termination rod including all fixing arrangements to walls and ceiling or laid in floors complete all as specified and directed. | 193.5 | RM | |
| 98 | 98 | Test point terminal block of gun metal or phosphorus bronze of size 75 x 75 x 25 mm, drilled and screwed including 3 nos., 8 mm dia 25 mm long hex head screw complete all as required at site and directed . | 21 | Each | |
| 99 | 99 | Aluminium strip of size 25 x 3.15 mm with and including PVC saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed . | 600 | RM | |
| 100 | 100 | Plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for support block of GI pipes and air termination rod complete all as specified and directed . | 0.44 | Cum | |
| 101 | 101 | Galvanised iron strip of size 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. | 30 | RM | |
| 102 | 102 | Earthing complete with Galvanised steel earth plate electrode, 600 mm x 600 mm x 6 mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below ground level connected to GI strip of size 32 X 6 mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, alternate layer of charcoal and salt, 40mm thick pre-cast PCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed.\nNotes: \n1. Earth lead & protection pipes length upto & including 7.50 metre.\n2. Earth filling shall be done by vegitable soil.\n3. Soil should be free from stone, boulders, aggregate, gravels etc. | 21 | Each | |
| 103 | 103 | Supply, installation, commissioning and testing of diesel engine driven generating set complete with acoustic enclosure approved by CPCB-2 and control system for 10 KVA output at site, AC 415 volts, 50 C/S, 3 phase 4 wire directly coupled complete with self starting system including accessories, equipment control panel etc as detailed below (A) DIESEL ENGINE :- Diesel driven engine of suitable capacity to drive alternator of cap 10 kVA, water cooled and electric start, coupled directly through flexible coupling, multi cylinder, four storke, 1500 RPM complete with following standard accessories as per manufacturer recommendations or all as specified and directed. (a) The gen set should have capacity to run continously in variable load condition for unlimited hours and should also have a 110% load capacity of 01 hour in every 12 hours of operation. (b) Air System - Inlet & Exhaust comprising (i) Dry-type paper element air Cleaner (ii) Restriction Indicator / Vacuum Indicator (iii) Optimised Turbocharger (iv) Intake Manifold (v) Exhaust Manifold (vi) Silencer muffler and (vii) Stainless steel Exhaust Flexible coupling | 3 | Each | |
| 104 | 103.1 | (c) Cooling System comprising (i) Radiator to suit ambient conditions (ii) Cooling system piping (iii) Thermostates (iv) Pressure cap (v) Coolant Inhibitor and (vi) Engine Driven Fan (d) Fuel System comprising (i) Fuel pump -Low pressure type (ii) Injectors (iii) Cartridge paper filters primary and secondary for Fuel (e) Governor :- Engine Electronic Governor for A1 governing of engine speed from No load to full load. (f) Lub Oil System :- (i) Plate Type lub oil cooler (ii) filters-lubrication oil (g) Electric Starting system comprising (i) Electrical starter - 12 Volts (ii) Engine driven battery charging alternator (iii) Cut Out and (iv) One No of 12 volts of 150 AH maintenance free battery with suitable connection terminals and leads for proper battery connection | |||
| 105 | 103.2 | (h) Engine Monitoring, Protection and Diagnostics relay suitable to display (i) Lub oil Pressure (ii) Coolant Temperature (iii) Engine Speed \n(iv) Hours Run \n(v) Battery Voltage, Battery charging voltage \n(vi) Fuel level in percentage, \n(vii) AC Voltage 3 phase \n(viii) Current RYB 3 phase \n(ix) Power Factor \n(x) Frequency (xi) KVA \n(xii) Kilowatt and suitable for\n (i) Start and Stop \n(ii) Common Shutdown \n(iii) High coolant temp warning and shutdown \n(iv) Low tube oil pressure warning and shutdown\n (v) Low fuel level shutdown \n(vi) Overspeed shutdown \n(vii) Alternator Protection\n (viii) Over voltage \n(ix) Under voltage \n(x) Over and under frequency \n(xi) Over current\n | |||
| 106 | 103.3 | (i) Engine fitted with low lube oil pressure (LLOP) & high water temperature (HWT) Safety devices and also fitted with requisite temperature and pressure gauges.\n(l) Misc Accessories i.e - (i) Flywheel Housing (ii) Flywheel (iii) Anti-vibration pads \n(iv) Emergency stop push button etc all as required for smooth operation of DG set or recommended by manufactrurer\n(B) ALTERNATOR :- Self excited, self regulated screen protected drip proof type with Class 'H' Insulation Salient pole revolving field and electronic Automatic Voltage Regulator for voltage regulation of + 0.5% from No load to full load, standard enclosure 415 Volt 50 HZ 4 pole 10 KVA cap, mounted on rigid MS sheet channel base-frame complete as per IS-13364 and conf to IS-4722 or BS 5000 all as required or recommended by manufactrurer. | |||
| 107 | 103.4 | C) LT Control Panel:- AMF panel board indoor type made out of CRCA sheet 2mm thick totally enclosed, weather dust and vermin proof with front opening, 440 volts 3 phase 4 wire 50 Hz having aluminium bus bar of suitable capacity for three phases and neutral duly colour coated with coloured heat shrinkable PVC sheelves, Multifunctional digital controler relay for AMF operation and display of electrical parameters, manual Start/Stop facility, Two Nos Electrically operated contactor 4 pole of suitable capacity for DG set and main supply, complete all as specified, contractor on indication, controller off indication, Phase Indicators, engine start push button, engine stop push button and fault accept / reset push button including battery charger comprising transformer, rectifier, resistance, DC volt meter DC Amp meter and charge rate selector switch, all accessories prewired with suitable size copper conductor cable or strip all as required or recommended by manufacturer\n(D) Acoustic Enclouser :- Shall be suitable to confirm Central Pollution Control Board (CPCB) norms of 75 DBA within 1 meter under free field conditions, having air inlet louvers specially designed to operate at rated load even at ambient conditions on air inlet temperature,powder coated for long lasting service life and superior finish with UV resistant powder coating to with stand extreme environments, designed to have minimum ease for unloading & shifting , i.e with central lifting facility, rust free hardware made of stainless steel, Insulation material to meet IS:8183 specifications. | |||
| 108 | 103.5 | ( E) Fuel Tank: Daily service fuel tank of sheet metal, suitable enough for minimum 8 hours running of DG, complete with drain valve, air vent, inlet, outlet connections.(F) Foundation :- PCC 1:2:4 foundation for DG set all as per manufacturer recommendation or required at site or directed by Engineer-in-charge. | |||
| 109 | 104 | Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following :\nIncoming: \n (a) Bus bar chamber comprising 4 Nos Aluminium Strip of size (25 x 5) mm PVC sheathed with colour coding.\n(b) MCCB having current rating 25 Amps with rupturing cap 16 KA , AC 415 Volts three pole complete with spreader links. (Qty -01 No)\n | 3 | Each | |
| 110 | 104.1 | (c) Ammeter and Voltmeter of suitable range with selector switch.d) CT and PT of suitable capacity including wiring using PVC insulated copper conductor as per standard engineering practice.(c) LED Phase Indicator Lamp R-Y-B (Set of Three).\nOutgoing \n(a) MCB having current carring rating 6 Amp with rupturing capacity 10 KA , AC 415 Volts 3 pole with complete with spreader links. (Qty- 3 Nos.)\nDistribution : 02 Nos MCB for Bunkers, 01 No MCB for POL Store. | |||
| 111 | 105 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core | 200 | RM | |
| 112 | 106 | Earthing complete with Galvanised steel earth plate electrode, 600 mm x 600 mm x 6 mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below ground level connected to GI strip of size 32 X 6 mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, alternate layer of charcoal and salt, 40mm thick pre-cast PCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed.\nNotes: \n1. Earth lead & protection pipes length upto & including 7.50 metre.\n2. Earth filling shall be done by vegitable soil.\n3. Soil should be free from stone, boulders, aggregate, gravels etc. | 18 | Each | |
| 113 | 107 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 14930 Part-II, of outer dia of 50 mm and inner dia 38' mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed. | 170 | RM |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy