Petty Repair Works Of Internal And External Electrical Day To Day Complaints At Ins Hansa Under Age Em I Of Ge Nw Vasco 8290/E8
Tender Value
20 Lakhs
Estimated cost
Bid Submission
08 Sep 2020
0 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
VASCO → Goa
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Petty Repair Works Of Internal And External Electrical Day To Day Complaints At Ins Hansa Under Age Em I Of Ge Nw Vasco 8290/E8
BOQ
| NAME OF WORK : PETTY REPAIR WORKS OF INTERNAL AND EXTERNAL ELECTRICAL DAY TO DAY COMPLAINTS AT INS HANSA UNDER AGE E/M-I OF GE (NW) VASCO. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Petty repairs of day to day complaints of internal Electric supply for Tech Bldg at INS Hansa areas comprising the following items including testing and commissioning all as directed:- | |||
| 2 | 1.01 | Supply and fix in repairs switch socket combinations 2 in 1, 5 A 3 Pin and 5 A 2 Pin combined flush type. | 500 | Each | |
| 3 | 1.02 | Supply and fix in repair switch socket combination 2 in one 3 pin 5 A and 3 pin 15 A Combined flush type. | 400 | Each | |
| 4 | 1.03 | Supply and fix in repair switch Piano, flush type single pole one way 5 Amp. | 500 | Each | |
| 5 | 1.04 | Supply and fix in repair bell push piano flush type. | 20 | Each | |
| 6 | 1.05 | Supply and fix in repair Buzzer, ding dong AC 230 V, Single pole. | 20 | Each | |
| 7 | 1.06 | Supply and fix in repair Ceiling fan regulator stepped type 120 Watt single phase 230 V. | 250 | Each | |
| 8 | 1.07 | Supply and fix in repair MCB 6 to 32 A, Single pole 10 KA, 240 V/ 415 V, C Series. | 60 | Each | |
| 9 | 1.08 | Supply and fix in repair MCB, 4 Pole, 6-32 A, 10 KA, 415 V, C-Series. | 20 | Each | |
| 10 | 1.09 | Supply and fix in repair MCB 4 Pole 63 Amps 415 V, C Series. | 12 | Each | |
| 11 | 1.1 | Supply and fix in repair single pole and neutral enclosure with two pin and earth plug and socket complex complete with one single pole MCB 20 Amps 10 KA. | 10 | Each | |
| 12 | 1.11 | Supply and fix in repair MCCB 4 Pole 100 Amps, 16 KA | 8 | Each | |
| 13 | 1.12 | Supply and fix in repair RCCB, Double pole 300 MA, 40 Amps | 5 | Each | |
| 14 | 1.13 | Supply and fix in repair Ceiling rose 3 terminals, PVC/Polycarbonate Isolated body with ISI Mark. | 300 | Each | |
| 15 | 1.14 | Supply and fix in repair Lamp Holder PVC / Polycarbonate type with pack plate suitable for battern fittings including fixing on suitable PVC Rectangular blocks. | 500 | Each | |
| 16 | 1.15 | Supply and fix in repair sheet metal enclosure suitable for mounting of MCCB 4 Pole 100 Amps, including fastener, nut bolts, connection wire and all other connected accessories. | 5 | Each | |
| 17 | 1.16 | Supply and fix in repair Ceiling fan capacitor 2.5 MFD Single phase 415 V. | 400 | Each | |
| 18 | 1.17 | M&L for removing the Ceiling fan , opening the fan motor servicing including replacement of worn out nut, bolts, washers, split pins, ball bearing etc greasing, assembling back and fixing its original position, testing and commissioning all as directed.\nNote : Ball bearing and sleeve bearing shall be measured and paid separately under supply only items. | 500 | Each | |
| 19 | 1.18 | Supply and fix in repair ball bearing suitable for any size of Ceiling Fans. | 200 | Each | |
| 20 | 1.19 | Supply and fix in repair plastic canopy top and bottom with tighten screw suitable for ceiling fan of any sweep/type. | 200 | Each | |
| 21 | 1.2 | Fixing only in repair Highbay lights any type and capacity inside the hangar including necessary nut bolts all as directed. \n(Note : Item will be issued in Sch 'B' store) | 70 | Each | |
| 22 | 1.21 | Fixing only LED tube rod, retrofit type including making necessary changes in wiring all as directed.\n(Note : Item will be issued in Sch 'B' store) | 600 | Each | |
| 23 | 1.22 | Supply and fix in repairs LED tube light fitting and tube light 1 x 18 Watts 4 feet long, 230V indoor decorative aluminum extruded LED integrated batten, complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed. \nMake :- Havells/ Sakthi/Bajaj | 50 | Each | |
| 24 | 2 | M & L opening the body cover of ceiling fan, exhaust fan, air circulator, pedestal fan any type, any make and cutting the existing winding without damaging the starter removing the coil insulation and putting new wire of suitable gauge with correct number of turns of auxiliary and main winding, varnishing and baking complete and soldering new lead of copper wire three core cables of size 23/0.0076 testing complete including transportation from area of AGE E/M-I to workshop all as directed :- | |||
| 25 | 2.01 | C/Fan 1200/1400mm sweep | 50 | Each | |
| 26 | 2.02 | Exhaust fan up to 300 mm sweep | 20 | Each | |
| 27 | 2.03 | Exhaust fan up to 450 mm sweep | 10 | Each | |
| 28 | 2.04 | Flame proof exhaust fan up to 300 mm sweep | 10 | Each | |
| 29 | 2.05 | Wall mounting fan up to 700 mm sweep | 18 | Each | |
| 30 | 3 | Attending complaints for day to day repair / maint work for Hangar light/ outer/inner perimeter / security / street / dispersal / high mast / search lights / any description at INS Hansa area by taking down carefully the existing non operational / unserviceable lights from and description, repair / replacement of unserviceable spares and re-fixing the same in the existing location after completion of repair work complete all as specified and directed by Engineer-in-Charge.\nNote :- (a) All new spares for the above lights will measured and paid separately under relevant item of this schedule. | 800 | Each\n | |
| 31 | 3.01 | (b) The contractor / contractor's supervisor shall be report to AGE E/M-I / INS Hansa maint office in all working days at 0900 AM and collect the complaint slip for defect / unserviceable lights list at Hansa premises and carrying out and complete the repair work in the same day before 1800 hrs. If the contractor fails to complete the repair work within the 03 working days after receipt of complaint slip necessary recovery @ Rs 100.00 per fittings per day shall be recovered from the actual workdone. For that the register shall be maintained and signed by both the Engineer-in-Charge and contractor.\n(c) Rate for all Tools and plants, safety equipments, transport including necessary minor spares such as insulation tape, connectors, fixing screws, connecting 2 core wires up to 2 mtr length shall be included in the quoted rates.\nNote: New Spares will be measured & paid under relevant items as supply only | |||
| 32 | 3.02 | Supply only heavy duty copper ballast for HPSV/MH 400W high bay fitting complete all as specified and directed by Engineer-in-Charge.\n(Make : Philips, C & S, Havells) | 40 | Each | |
| 33 | 3.03 | Supply only heavy duty copper ballast for HPSVMH 250W high bay fitting complete all as specified and directed by Engineer-in-Charge.\n(Make : Philips, C & S, Havells) | 15 | Each | |
| 34 | 3.04 | Supply only MH lamps 400W of hangar light fitting complete all as specified and directed by Engineer-in-Charge.\n(Make : Philips, C & S, Havells) | 60 | Each | |
| 35 | 3.05 | Supply only MH lamps 250W of hangar light fitting complete all as specified and directed by Engineer-in-Charge . \n(Make : Philips, C & S, Havells) | 20 | Each | |
| 36 | 3.06 | Supply only ignitor suitable for MV & MH lamp 250-400W complete all as specified and directed by Engineer-in-Charge.\n(Make : Philips, C & S, Havells) | 50 | Each | |
| 37 | 3.07 | Supply only Porcelain holder threaded type for 400/250W HPSV/ HPMV lamp complete all as specified and directed by Engineer-in-Charge. \n(Make : Philips, C & S, Havells) | 20 | Each | |
| 38 | 3.08 | Supply only capacitor 33 mfd, 250V complete all as specified and directed by Engineer-in-Charge. \n(Make : Philips, C & S, Havells) | 50 | Each | |
| 39 | 3.09 | Supply only LED driver with transformer suitable for 25 to 45 watts LED street/ceiling panel light fitting of complete all as specified and directed by Engineer-in-Charge.\nMake:-Philips/Bajaj/Havells make . | 20 | Each | |
| 40 | 3.1 | All as per item No. 3.09 above of capacity 60 to 120 watts LED fittings complete all as specified and directed by Engineer-in-Charge. | 30 | Each | |
| 41 | 3.11 | All as per item No. 3.09 above of capacity 150 to 300 watts LED fittings complete all as specified and directed by Engineer-in-Charge. | 20 | Each | |
| 42 | 4 | M & L Point wiring for one light point or one fan point controlled by one switch with 1.5 Sqmm PVC insulated 1100 V grade multistranded copper conductor in PVC Casing and Capping including provision of 1.5 Sqmm PVC insulated copper conductor as earth continuity conductor all as directed. | 300 | Point | |
| 43 | 5 | All as per item No.4.00 above but for one 5A socket out let on independent board. | 40 | Point | |
| 44 | 6 | All as per item No.4.00 above but for one 5A Socket out let on same board with other switches. | 100 | Point | |
| 45 | 7 | All as per item No.4.00 above but for one 15 A Socket out let with 2.5 Sqmm Copper conductor including provision of 2.5 Sqmm PVC Insulated copper conductor as earth continuity conductor all as directed. | 50 | Point | |
| 46 | 8 | Taking down unserviceable point wiring copper or Aluminium (light, fan, or Sockets) completely including making good disturbed surfaces all as directed. | 490 | Point | |
| 47 | 9 | M & L Painting of Ceiling fans complete in site with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. | 500 | Each | |
| 48 | 10 | Checking of Ceiling fan complete in situ for proper fitment including . Checking of rubber reel, split pin, nut bolts, fan rod, fan clamp etc and replacement of defective / worn out split pin, nut bolts rubber red etc all as directed. | 600 | Each | |
| 49 | 11 | Periodical Inspection of Water Geyser 25 Ltrs / 50 Ltrs Capacity including checking of Built Safety valve, Neon Indication Lamp, Fussible metal plug Temperature Control knob, Thermostate, thermal Cut out Heating Control etc for proper function and reset if required or replace if unserviceable all as directed. For replacement, item shall be measured under supply only as shown against item No-14 below:- | 30 | Each | |
| 50 | 11.01 | Supply only Heating Element suitable for Existing Water Geyser of Capacity 25 Ltrs / 50 Ltrs of any make. | 30 | Each | |
| 51 | 11.02 | Supply only safety valve suitable for existing 25 Ltrs /50 Ltrs capacity water Geyser of any make. | 20 | Each | |
| 52 | 11.03 | Supply only thermostat suitable for 50 Ltrs /25 Ltrs Capacity water Geysers of any make. | 30 | Each | |
| 53 | 11.04 | Supply only thermal Cut out bimetallic type suitable for 25 Ltrs /50 Ltrs capacity water Geyser. | 20 | Each | |
| 54 | 11.05 | Supply only Neon Indication Lamp suitable for water Geyser on / off indication. | 20 | Each | |
| 55 | 12 | M & L Aluminium conductor, steel reinforced of any size as per site requirement including fixing on LT Pole Insulators, Jumpers etc including dismantling old U/S Conductor. | 0.5 | Per\n Quintal | |
| 56 | 13 | Attending Electrical complaints like short circuit, No supply, wire burnt in switch boards etc in residential accomodation /offices including fault findings, rectification and testing all as directed by Engineer-in-Charge.\nNote: Material like wire for replacement if required shall be measured and paid separately under supply only. | 200 | Each\nJob | |
| 57 | 14 | Supply only PVC insulated multistranded Copper Conductor Cable 1100 V grade 1.5 Sqmm size for day to day repair work. | 180 | RM | |
| 58 | 15 | All as per item No.14.00 above but of size 2.5 Sqmm. | 180 | RM | |
| 59 | 16 | All as per Item No.14.00 above but of size 4 Sqmm. | 180 | RM | |
| 60 | 17 | Supply and fix in repair LT Cable jointing kit outdoor type straight through joint of size 70 Sqmm to 120 Sqmm including necessary excavation upto 2.5 Cum and making good the excavated area all as directed. | 2 | Each\nJob | |
| 61 | 18 | All as per item No.17.00 above for cable size 185 Sqmm to 240 Sqmm | 2 | Each \nJob | |
| 62 | 19 | Attending Electrical Complaints such as, LT UG Cable end Connection burnt at substation, cutting and reconnection of LT UG Cable at substation, replacement of burnt LT UG Cable lugs etc all as directed.\nNote: Cable lugs shall be measured and paid separately under supply only item. | 50 | Each \nJob | |
| 63 | 19.01 | Supply only LT UG Cable lugs Aluminium of size upto 50 Sqmm. | 100 | Each | |
| 64 | 19.02 | All as per item No.19.00 above but of size70 sqmm to 95 Sqmm. | 50 | Each | |
| 65 | 19.03 | All as per item No.19.00 above but of size 240. | 20 | Each | |
| 66 | 19.04 | All as per item No.19.00 above but size 185 Sqmm. | 20 | Each | |
| 67 | 20 | Servicing of 4 pole structures LT/HT including checking all joints, jumbers etc for any loose connection, replacement of burnt jumber with new one, replacement of rusted nut bolts and apply petroleum jelly for all moving contacts all as directed by Engineer-in-Charge. \nNote:- All the spares required for the work is included in the quoted rate. | 20 | Each Job | |
| 68 | 21 | Material and labour for Servicing of earth pit structure by disconnecting earth strip by opening nuts and bolts 4 pole structures LT/HT including checking all joints, jumbers etc for any loose connection, replacement of burnt jumber with new one, replacement of rusted nut bolts and apply petroleum jelly for all moving contacts all as directed by Engineer-in-Charge. \nNote:- All the spares required for the work is included in the quoted rate. | 200 | Each Job | |
| 69 | 22 | Labour only for removing all vegetation and cutting of tree branches from Electric poles of any size and length all as directed | 100 | Each Pole |
AI Tender Summary
Tender Timeline
Aug 11, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 10, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓