Tender For Electrical Works At State Health Society Nhm Nagrota.
Tender Value
12.63 Lakhs
Estimated cost
Bid Submission
18 Aug 2020
0 days left
EMD
25260
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
NHM Nagrota Jammu → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Electrical Works At State Health Society Nhm Nagrota.
BOQ
| Name of Work: Electrical Works at State Health Society NHM Nagrota. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Supply Installation, Testing and commissioning of Pre-wired recess mounth 2ft x 2ft. LED Panel fitting with Drives etc including connections with 1.5sqmm . FRLS PVC Insulated Copper conductor single cove cable and earthing etc as required. Make wipro/Havells/ Jaquar/ Phillips / HPL | 30 | No | |
| 2 | 2 | Supply, Installation, Testing and Commissiong of Pre- wired reecrs mounted LED ceiling Light 12W including connections with 1.5 sqmm PRLS PVC Insulated copper conductor single cove cable and earthing as required. Make : Wipro/ Havells/ Jaquar/ Philips/ HPl. | 40 | No | |
| 3 | 3 | Supply, Installation, Testing and Commissioning of Wall Fan. Make: Havells/ORIENT/V-Guard/ Standard | 20 | No | |
| 4 | 4 | Supply, Installation, Testing and Commissiong of Ceiling fan, capautor type soctable for Low voltage operation including wiring the down rods of Standard Length (upto 30cm) with 1.5 sqmm FRLS PVC Insulated copper conductor single cove cable including P/F Phenolic Laminated sheet cover on the fan box etc as required (1200mm sweep 5 Star) Make: Havells/V-Gaurd/ Orient/ Standarad | 20 | No | |
| 5 | 5 | Supply, Installation, Testing and Commissiongof Split Air Conditioners(Hot & Cold) Make: Diakin/o-General/L.G/Voltas | |||
| 6 | 5.01 | 1.5 Ton | 5 | No | |
| 7 | 5.02 | 2.0 Ton | 7 | No | |
| 8 | 6 | Supply, Installation, Testing and Commissiong of Exhaust Fan with Louvers of following sizes including connections etc as required (complete job) 300 mm Make: Havells/V-gauard/Orient /Standarad | 6 | No | |
| 9 | 7 | Supply, Installation, Testing and Commissiong of Digital Automatic Stanlozer of following ratings Make: V-gauard/Mocrotek /Livgaurd | |||
| 10 | 7.01 | 4 KVA (90 v to 290 volt) | 5 | No | |
| 11 | 7.02 | 5 KVA (90 v to 290 volts) | 7 | No | |
| 12 | 8 | Supply, Installation, Testing and Commissiong of 12.7 mm and 6.4 mm dia Copper Pipe for Non-VRV Air Conditioning System (Compete Job) ISI | 20 | Mtr | |
| 13 | 9 | Supply, Installation, Testing and Commissiong of Fire Extinguisher,ABC Dry Powder Type of 6 kg Make: SAVMAX/Life guard/Cease fire | 6 | No | |
| 14 | 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (ISI). | |||
| 15 | 10.01 | 5/6 A switch | 160 | No | |
| 16 | 10.02 | 3 pin 5/6 A socket outlet | 50 | No | |
| 17 | 10.03 | 15/16 A switch | 68 | No | |
| 18 | 10.04 | 6 pin 15/16 A socket outlet | 62 | No | |
| 19 | 11 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required (ISI). | |||
| 20 | 11.01 | 63 A TP&N | 6 | No | |
| 21 | 11.02 | 100 A TP&N | 1 | No | |
| 22 | 12 | Supplying , Installation, Testing ,making Internal wiring connection and Commissioning of wall mounted distribution panel board with following details suitable for 415 Volt 3-phase-4 wire 50 Hz AC Supply | |||
| 23 | 12.01 | Panel fabrication details | |||
| 24 | 12.02 | Size 914 mm X 914 mm X 610 mm | |||
| 25 | 12.03 | MSCR Sheet | |||
| 26 | 12.04 | Main Frame 16 guage sheet with lifting | |||
| 27 | 12.05 | Partition with Hooks 16 guage sheet | |||
| 28 | 12.06 | Gland & plates 16 gauge Sheet | |||
| 29 | 12.07 | Power coating Simens grey | |||
| 30 | 12.08 | Material list for panel board | |||
| 31 | 12.09 | Providing and fixing following rating breaking capacity and poles MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including panel board including drilling holes in cubical panel making connection etc as required. 100 A, 30KA,FPMCCB 1 no. (ISI) | |||
| 32 | 12.1 | Providing and fixing capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubical panel making connections etc as required | |||
| 33 | 12.11 | 63 A TP&N= 1 no. | |||
| 34 | 12.12 | 32 A TP&N = 1 no. | |||
| 35 | 12.13 | Onload changeover Swtich - 4 pole 63 AMP :- 1 No. (ISI) | |||
| 36 | 12.14 | Volt meter 1 No. | |||
| 37 | 12.15 | Ammeter 1 No. | |||
| 38 | 12.16 | Indicator Lamp 1 set | |||
| 39 | 12.17 | The panel Board should include all wiring with respect to load & all allied accessories for Complete Job. | 1 | No | |
| 40 | 12.18 | Panel fabricator CPRI Approved | |||
| 41 | 13 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (ISI) | |||
| 42 | 13.01 | Double pole | 10 | No | |
| 43 | 13.02 | Single Pole | 60 | No | |
| 44 | 14 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A (ISI) | 8 | No | |
| 45 | 15 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required) (ISI) | |||
| 46 | 15.01 | 12 way (4 + 36), Double door | 1 | No | |
| 47 | 16 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. | |||
| 48 | 16.01 | 200 A, 25 KA,TPMCCB (ISI) | 1 | No | |
| 49 | 17 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (ISI) | |||
| 50 | 17.01 | 1 or 2 Module | 2 | No | |
| 51 | 17.02 | 3 Module | 2 | No | |
| 52 | 17.03 | 4 Module | 12 | No | |
| 53 | 17.04 | 6 Module | 4 | No | |
| 54 | 17.05 | 8 Module | 15 | No | |
| 55 | 17.06 | 12 Module | 6 | No |
AI Tender Summary
Tender Timeline
Aug 11, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 19, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender