Repair/Maintenance Of External Water Supply , Submersible Pump Sets Etc . And Other Miscelleneous Works At Afs Samana

Issued by Statutory Bodies & Commissions/Committees · SAMANA, Gujarat
Tender Value
30 Lakhs
Estimated cost
Bid Submission
18 Aug 2020
0 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
SAMANA → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair/Maintenance Of External Water Supply , Submersible Pump Sets Etc . And Other Miscelleneous Works At Afs Samana

BOQ

Name of Work: REPAIR/MAINTENANCE OF EXTERNAL WATER SUPPLY,SUBMERSIBLE PUMP SETS ETC. AND OTHER MISCELLENEOUS WORKS AT AFS SAMANA (3rd call)
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for laying pipe line etc not exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft / loose soil omplete all as specified and as directed by Engineer-in-Charge.\n\n165Cum
22Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soft / loose soil omplete all as specified and as directed by Engineer-in-Charge.\n\n65Cum
33Removing excavated soil to a distance n exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.\n\n100Cum
44Supply and fix in repair / laid in trenches 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge. \n\n300RM
55Supply and fix in repair / laid in trenches 40 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge. \n\n160RM
66Supply and fix in repair / laid in trenches 50 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge. \n\n100RM
77Supply and fix in repair / laid in trenches 80 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge. \n\n30RM
88Supply and fix in repair/ laid in trenches 100 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge. \n\n30RM
99Supply and fix in repair on wall or laid on floor 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge. \n\n200RM
1010Supply and fix in repair on wall or laid on floor 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge. \n\n200RM
1111S & F in repair 15 mm size bib tap PTMT , fancy type, screwed down, high pressure with capstan head, screwed for iron pipe or for union omplete all as specified and as directed by Engineer-in-Charge. \n\nMake :- Prayag Cat No 121F or equivalent of makes listed in PS Appx 'B'\n\n50Each
1212Supply and fix in repair on wall or laid on floor 20 mm bore galvanised steel water tubing, light grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line including taking down old pipe complete all as specified and as directed by Engineer-in-Charge. \n\n150RM
1313S&F in repair 25mm bore 3-layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including taking down old pipe omplete all as specified and as directed by Engineer-in-Charge.\n\n150RM
1414S&F in repair 32mm bore 3-layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.\n\n100RM
1515Supply and fix in repair PP-R gate valve (brass insert) of size 25 mm bore as per requirement at site complete including taking down unserviceable complete all as specified and as directed by Engineer-in-Charge.\n\n60Each
1616Supply and fix in repair PP-R gate valve (brass insert) of size 32 mm bore as per requirement at site complete including taking down unserviceable complete all as specified and as directed by Engineer-in-Charge.\n\n80Each
1717Supply & fix in repair HDPE pipe of outer dia 50 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge. \n\n110RM
1818Supply & fix in repair HDPE pipe of outer dia 80 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge. \n\n70RM
1919Supply & fix in repair HDPE pipe of outer dia 100 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge. \n\n50RM
2020Supply & fix in repair HDPE pipe of outer dia 150 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge. \n\n100RM
2121Supply & fix in repair HDPE pipe of outer dia 180 mm confirming to IS - 4984, ISI marked, working pressure PE-63, PN-10 rating, including jointing material, clamps and nut bolts washers. etc, laid in trenches or fixed on wall all as specified and directed by Engr In charge. \n\n200RM
2222S&F in repair 25 mm size gun metal gate valves ISI marked with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.\n\n40Each
2323S&F in repair 40 mm size gun metal gate valves ISI marked with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.\n\n10Each
2424S&F in repair 50 mm size gun metal gate valves ISI marked with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.\n\n10Each
2525Supply and fix in repair 80 mm size cast iron sluice valve, long body type of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 including taking down old valve complete all as specified and as directed by Engineer-in-Charge.\n\n1Each
2626Supply and fix in repair 100 mm size cast iron sluice valve, long body type of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 including taking down old valve complete all as specified and as directed by Engineer-in-Charge.\n\n4Each
2727Supply and fix in repair 150 mm size cast iron sluice valve, long body type of pressure rating PN-1.6 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 including taking down old valve complete.\n\n1Each
2828Supply and fix in repair Automatic starter in SS enclosure suitable for single phase submersible motor of capacity 2 HP with complete connection.\n\n2Each
2929S&F in repair submersible Automatic star delta pump controller of capacity 20 HP with sheet metal enclosure including on off switch Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D,relay range 28-40 Amps, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, ON/ OFF Rocker switch ,voltmeter with selector switch suppressed scale ammeter, provided with Motor ON & Trip LED Indicator including taking down unserviceable starter complete all as specified and as directed by Engineer-in-Charge.\n\nMake:- L&T/ C&S or equivalent of makes listed in PS Appx 'B'\n\n2Each
3030Material and labour for Rewinding of monoblock centrifugal pump set 1 HP capacity of booster pump by cutting down and removing existing burnt out copper winding ,cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) complete including varnishing, drying, opening and fixing in the same position ,and testing of motor complete all as specified and as directed by Engineer-in-Charge.\n\n4Each
3131Taking out submersible pump set of any capacity from the tube well lowered at the depth of 130 mtrs from the ground level along with taking out GI / HDPE Pipes & 2 run of flat submersible cable after disconnecting electrical and outlet connection , lowering the same pump after repairing / servicing along with HDPE Pipe and electric cable including fixing of cable to pipe with PVC strip , replacement of clamps and mild steel bolts, nuts and washers, casing caping bell cap etc, connecting electrical connection and delivery pipe line complete all as specified and as directed by Engineer-in-Charge. \n\n8Job
3231.01Note: (i) Repair/servicing of submersible pump & motor will be measured and paid separately under this schedule.\n\n
3332M&L for repairing / servicing/rewinding of 17.5 HP capacity submersible motor multistage by dismantling the pump ,replacing the worn out bearings 02 Nos.,Bush 01 No., Stage bushing 01 No. Sleeves 01 No. Oil Sleeve 01 No.,Non Return Valve 01 No., Stainless steel filter cage 01 No. etc and malting of pump shaft including grinding and polishing ,reassembling the pump and testing complete all as specified and as directed by Engineer-in-Charge. \n\n3Job
3433Material and labour for Rewinding of open well nonclog submersible pump set of capacity range 20-30 HP by cutting down and removing existing burnt out copper winding ,cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) complete including varnishing, drying, ovening and fixing in the same position ,and testing of motor complete all as specified and as directed by Engineer-in-Charge.\n\n2Job
3534Material and labour for dismantling of existing monoblock submersible pump set of capacity 10 HP from dismantling the pump ,rewinding,replacing the worn out bearings 02 Nos.,Bush 01 No., Stage bushing 01 No. Sleeves 01 No. Oil Sleeve 01 No. etc and matling of pump shaft including grinding and polishing ,reassembling the pump and testing complete all as specified and as directed by Engineer-in-Charge. \n\n2Job
3635Material and labour for Rewinding of monoblock centrifugal pump set 5 HP capacity by cutting down and removing existing burnt out copper winding ,cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) complete including varnishing, drying, ovening and fixing in the same position ,and testing of motor complete all as specified and as directed by Engineer-in-Charge.\n\n2Job
3736Material and labour for Rewinding of monoblock centrifugal pump set 20 HP capacity by cutting down and removing existing burnt out copper winding ,cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) complete including varnishing, drying, ovening and fixing in the same position ,and testing of motor complete all as specified and as directed by Engineer-in-Charge.\n\n2Job
3837Supply and fix submersible pump cable flat , PVC insulated, PVC sheathed, multistranded copper conductor of size 10 Sqmm 3 core 1100 volt grade & connecting complete including taking down unserviceable cables complete all as specified and as directed by Engineer-in-Charge.\n\n500RM
3938M&L for Cleaning of overhead water tank of capacity 5,000 Gallons by removing sludge, mud or any other foreign material from the bottom and internal surface of tank by wire brushing, cleaning with fresh water, bailing out complete water with pump sets, washing of internal surface with sufficient quantity of........\n\n2Each Job
4038.01.........water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water), finally applying two coats of lime washing on entire internal surface, writing the date of cleaning and capacity of tank with white synthetic enamel paint on black background with synthetic enamel paint complete all as directed by Engineer-in-charge.\n\n
4139M&L for Cleaning of Static water tank of capacity 10,000 Gallons by removing sludge, mud or any other foreign material from the bottom and internal surface of tank by wire brushing, cleaning with fresh water, bailing out complete water with pump sets, washing of internal surface with sufficient quantity of water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water), finally applying two coats of lime washing on entire internal surface, writing the date of cleaning and capacity of tank with white synthetic enamel paint on black background with synthetic enamel paint complete all as directed by Engineer-in-charge.\n\n4Each Job
4240M&L for Cleaning of Static water tank of capacity 1,00,000 Gallons by removing sludge, mud or any other foreign material from the bottom and internal surface of tank by wire brushing, cleaning with fresh water, bailing out complete water with pump sets, washing of internal surface with sufficient quantity of water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water), finally applying two coats of lime washing on entire internal surface, writing the date of cleaning and capacity of tank with white synthetic enamel paint on black background with synthetic enamel paint complete all as directed by Engineer-in-charge.\n\n5Each Job
4341Supply and installation, testing, commissioning of factory made, CPRI approved, outdoor type, LT Panel board, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specified and directed & Consisting of the following equipment's:-\n\n1Each Job
4441.01(a) Aluminium bus bar of capacity 300 Amps for Phase and 150 Amps for Neutral - 01 set\n\n(b) Incoming MCCB 200 Amps, Breaking capacity 25 kA, 4 Pole, - 01 No\n\n(c) Outgoing MCCB 63Amps, Breaking capacity 16 kA, 3 Pole, - 02 Nos \n \n(d) Outgoing MCCB 100 Amps, Breaking capacity 16 kA, 3 Pole, - 01 Nos \n\n(e) Automatic star delta starter suitable for 25 HP Motor relay range up to 60 Amps - 01Nos.(Including Single phase preventer etc.)\n
4541.02(g) Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (Make HPL , Cat Part No NEMFVIFPPE000 or equivalent of Make : L & T / Secure / Conserve.)\n\n(h) Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set.\n\n
4641.03Note :- Quoted rates shall be deemed to include for grouting / fixing of bus bar chamber in PCC 1:3:6 type C2 and PCC block masonry with PCC block of mix 1:5:8 & plastering 10mm thick in CM 1:6 complete all as specified and directed by Engg-in-Charge\n\n
4742Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Panel board, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specified and directed & Consisting of the following equipment's:-\n\n1Each Job
4842.01(a) Aluminium bus bar of capacity 160 Amps for Phase and 80 Amps for Neutral - 01 set\n(b) Incoming MCCB 80 Amps, Breaking capacity 25 kA, 4 Pole, - 01 No\n\n(c) Outgoing MCCB 63Amps, Breaking capacity 16 kA, 4 Pole, - 01 Nos \n \n(d) Outgoing MCCB 32 Amps, Breaking capacity 16 kA, 4 Pole, - 03 Nos \n\n
4942.02(g) Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (Make HPL , Cat Part No NEMFVIFPPE000 or equivalent of Make : L & T / Secure / Conserve.)\n\n(h) Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set.\n\n
5042.03Note :- Quoted rates shall be deemed to include for grouting / fixing of bus bar chamber in PCC 1:3:6 type C2 and PCC block masonry with PCC block of mix 1:5:8 & plastering 10mm thick in CM 1:6 complete all as specified and directed by Engg-in-Charge\n\n
5143Periodical Preventive maintenance / servicing of solar water heater, glass tube collector / Flat plate collector system , storage type with electrical backup of capacity 100 - 500 litres, as per manufacturer instruction comprising of the following works at different locations at 77SU AFS Samana. \n\n
5243.01(a) Complete cleaning of solar system, removing of dirt dust etc.\n\n(b) Cleaning of heating surface glass with glass cleaning solution.\n\n(c) Opening of cold & hot water connection draining out deposited water removing of mud turbidity etc & cleaning with fresh water.\n\n(d) Checking of Non return valve, Electrical backup system & sacrificial anode & tighten the connection.\n\n(e) Checking of glass holding tube joint & rectification of leakage.\n(f) Replacement of unserviceable spare part. \n\n
5343.02Note:-\n(i) Preventive maintenance shall be carried out 2 times in a year (at the interval of 6 months approx) & shall be measured as one unit for payment.\n\n(ii) Unserviceable spares parts will be measured & paid separately as supply only.\n\n(iii) Work shall be executed through Authorised service technician of Tata Solar BP / Delta.\n\n(iv) Contractor shall submit the documentary evidence of Authorised service technician for the approval of GE before commencement of work.\n\n(v) Contractor shall submit certificate for every month, to Engineer-in-Charge, obtain from Authorised service centre that work has been executed by them. \n\n(vi) Above said certificate shall be endorsed by Engineer-In-Charge.\n\n
5443.03(a) 100 Ltrs capacity\n\n104Job
5543.04(b) 200 Ltrs capacity\n\n15Job
5643.05(c) 500 Ltrs capacity\n\n8Job
5744S&F in repair solar glass tube suitable for glass tube collector type solar water heater.\n\n80Each
5845S&F in repair Sacrificial Anode suitable for glass tube collector type solar water heater.\n\n10Each
5946Supply & fix in repair Electrical backup of capacity 1.5/2 KW, 230 V supply,including with thermosatate and relay suitable for glass tube/Plate collector type solar water heater. Sample is provided by the AGE (B&R) office.\n\n100Each
6047S&F in repair \"O\" ring glass tube type suitable for glass tube collector type solar water heater.\n\n30Each
6148S&F repair only Collector rubber gasket suitable for glass tube collector type solar water heater.\n\n30Each
6249M&L for Chemical cleaning of solar water tank by providing chemical & removing all scale / dirt / dust etc as per manufacturer's instruction complete all as specified and as directed by Engineer-in-Charge.\n\n115Each
6350S&F in repair hot water supply hose along with its two numbers round clip for connecting water supply from Solar water heater panel to its storage tank.\n\n50Each set
6451S&F in repair solar water heater storage tank only of capacity 100 LPD and fixed in its position along with removal of old one and connecting with its inlet and outlet pipe of solar heating panel complete all as specified and as directed by Engineer-in-Charge.\n\n20Each
6552S&F in repair solar water heater storage tank only of capacity 200 LPD and fixed in its position along with removal of old one and connecting with its inlet and outlet pipe of solar heating panel complete all as specified and as directed by Engineer-in-Charge.\n\n10Each
6653Deployment of man power for Collecting the sample of water from different point such as under ground sump , over head tank , open well, bore well and testing of water from reputed Govt laboratory for iron contain, PH value, Hardness, turbidity, chloride, fluoride and submitting the test report to Engineer-in-Charge.\n\nNote :- Testing of water shall be carried out two times during currency of contract with interval of 6 month (approx.) one time testing shall be measured as one Unit (Each Job) for payment.\n\n4Job
6754Deployment of man power for Collecting the sample of water from different point such as under ground sump , over head tank , open well, bore well and testing of water from reputed Govt laboratory for bacteriological test including arsenic test and submitting the test report to Engineer-in-Charge.\n\nNote :- Testing of water shall be carried out every 6 months during currency of contract and one time testing shall be measured as one Unit (Each Job) for payment.\n\n12Job
6855Surface cleaning / dressing by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, pruning of small branches of tree, weeds in soft loose soil all as specified and directed by Engineer- in-charge. \n\nNote:- This item shall be executed for cleaning of surrounding area of various E&M installation.\n\n1000Sqm
6956M&L for dismantling, taking out choke up radiator assembly, of 25 KVA DG Set, de-scaling, cleaning of fan and cooling coil fins including soldering / brazing at the leakage point re-fixing radiator assembly after repair complete all as specified and as directed by Engineer-in-Charge. \n\n1Each Job
7057M&L for dismantling, taking out choke up radiator assembly, of 50 KVA DG Set, de-scaling, cleaning of fan and cooling coil fins including soldering / brazing at the leakage point re-fixing radiator assembly after repair complete all as specified and as directed by Engineer-in-Charge. \n\n2Each Job
7158M&L for dismantling, taking out choke up radiator assembly, of 63 KVA DG Set, de-scaling, cleaning of fan and cooling coil fins including soldering / brazing at the leakage point re-fixing radiator assembly after repair complete all as specified and as directed by Engineer-in-Charge. \n\n1Each Job
7259M&L for taking out self starter of 12 / 24 volts DC from DG set, servicing of starter including replacement of clutch plate, moving control pinion, spring etc, fixed in same position complete all as specified & directed by Engineer-in Charge.\n\n2Each job
7360Service Charges for Carrying out the 'B' Check maintenance of DG set of 25 KVA capacity of make Greaves, from authorized service representative from the manufacturer of DG set, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters, checking inlet & Exhaust manifold cap screws, checking of fan hub & water pump, including supply & fix in repair of following spares :-\n\n5Each job
7461.01(a) Kit, fuel filter and ring - 2 Kit\n
7561.02(b)Element for Lubrication oil filter - 2 Nos.\n
7661.03(c) Kit, Element of super bypass filter - 01 Kit\n
7761.04(d) Seal, O Ring - 02 Nos\n
7862Service Charges for Carrying out the 'B' Check maintenance of DG set of 50 KVA capacity of make Greaves, from authorized service representative from the manufacturer of DG set, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters, checking inlet & Exhaust manifold cap screws, checking of fan hub & water pump, including supply & fix in repair of following spares :-\n\n2Each job
7962.01(a) Kit, fuel filter and ring - 2 Kit\n
8062.02(b)Element for Lubrication oil filter - 2 Nos.\n
8162.03(c) Kit, Element of super bypass filter - 01 Kit\n
8262.04(d) Seal, O Ring - 02 Nos\n
8363Service Charges for Carrying out the 'B' Check maintenance of DG set of 63 KVA capacity of make Greaves, from authorized service representative from the manufacturer of DG set, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters, checking inlet & Exhaust manifold cap screws, checking of fan hub & water pump, including supply & fix in repair of following spares :-\n\n2Each job
8463.01(a) Kit, fuel filter and ring - 2 Kit\n
8563.02(b)Element for Lubrication oil filter - 2 Nos.\n
8663.03(c) Kit, Element of super bypass filter - 01 Kit\n
8763.04(d) Seal, O Ring - 02 Nos\n
8864Supply and topping up Engine oil 15 W 40 in DG sets. \n\nMake - Castrol / BPCL / SERVO\n\n80Litre
8965Supply and topping up Coolant concentrate SK 802 01C.\n\nMake:- Servo / Valvoline / Hindustan.\n\n20Litre
9066Supply and topping up distilled water to be filled in batteries all as directed by Enggr-in-Charge \n\n40Litre
9167Supply and fix in repair 100 Amps contactor AC 3 phase 415 V 50 Hz coil 440 V.\n\n2Each
9268Supply and fix in repair 125 Amps contactor AC 3 phase 415 V 50 Hz coil 440 V.\n\n2Each
9369Supply and fix in repair 4 pole Mini contactor , with AC coil including overload relay of range 7-10 amps.\n\n3Each
9470Supply and fix in repair 4 pole Mini contactor , with AC coil including overload relay of range 12-16 amps.\n\n2Each
9571Supply and fix in repair thermal overload relay 3 pole of relay range 9-14 Amps.\n\n3Each
9672Supply & fix in repair battery lead of PVC insulated single core multistrandard copper conductor of size 20 Sqmm & 1.50 mete long cable, with lugs fixed in position as directed complete all as specified and as directed by Engineer-in-Charge.\n\n8Each set
9773S&F for repair in Right / Left hand lock with catcher for acoustic enclosure (canopy) of any capacity DG sets complete all as specified and as directed by Engineer-in-Charge.\n\n2Each
9874S&F in repair for Dial type mechanical fuel level indicator for any capacity DG set complete all as specified and as directed by Engineer-in-Charge. \n\n2Each
9975M & L for preparation of old painted exposed surface of DG set of capacity 25 to 63 KVA by removing dust, dirt, oil, grease etc & and painting with two coats of synthetic enamel paint of existing colour by using the air pressure spray gun machine, writing SM/ MES No to DG sets with white paint all as specified and directed by Engr-in-Charge.\n\n2Each
10076Supply and fix in repair lead acid battery 12 V 180 AH with initial charging, fixing & connecting, at site of DG set including taking out old battery all as directed by Engr-in-Charge. \n\n4Each
10177M&L for 100mm thick cement concrete 1:3:6 , type PCC cement concrete type C2 (using 40 mm graded stone aggregate)as in sub base /path/flooring complete all as specified and as directed by Engineer-in-Charge.\n\n90SQM
10278M&L for servicing/rewinding of bore well submersible pump multistage of capacity 20 HP with changing its bush , shaft, clamp and necessary grinding required in impeller to make it in good running position along with its gland and necessary fixtures complete all as specified and as directed by Engineer-in-Charge.\n\n10Each Job
10379M&L for servicing/rewinding of open well submersible pump of capacity 30 HP with changing its bush ,clamp and necessary grinding required in impeller to make it in good running position along with its gland and necessary fixtures complete as directed by Engr-in-charge.\n\n2Each Job
10480M&L for servicing/rewinding of monoblock pump of capacity 17.5 HP with changing its bush , shaft, clamp and necessary grinding required in impeller to make it in good running position along with its gland and necessary fixtures complete as directed by Engr-in-charge.\n\n2Each Job
10581M&L for repairing of crackle in 80 mm HDPE/DI/CI water pipe line by provodong galvanised mild steel two piece half round clamp fabricated with 300 mm long and 3mm thick galvanised mild steel sheet, bend to shape, or with MS pipe including 8 Nos galvanised nut bolt, rubber packing complete all as specified and as directed by Engineer-in-Charge.\n\n10Each Job
10682M&L for repairing of crack in 180 mm HDPE/DI/CI water pipe line by providing galvanised mild steel two piece half round clamp fabricated with 300 mm long and 3mm thick galvanised mild steel sheet, bend to shape, or with MS pipeincliding 8 Nos galvanised nut bolt, rubber packing complete all as specified and as directed by Engineer-in-Charge.\n\n15Each Job
10783M&L for repairing of crack in 100 mm HDPE/DI/CI water pipe line by providing galvanised mild steel two piece half round clamp fabricated with 300 mm long and 3mm thick galvanised mild steel sheet, bend to shape or with MS pipe including 8 Nos galvanised nut bolt, rubber packing complete all as specified and as directed by Engineer-in-Charge.\n\n10Each Job
10884M&L for repairing of crack in 180 mm HDPE/DI/CI water pipe line by providing D joint of cast iron along with its rubber ring including 8 Nos galvanised nut bolt, rubber packing complete all as specified and as directed by Engineer-in-Charge.\n\n6Each Job
10985S&F in repair cast iron Air release valve of size 40 mm .\n\n5Each
11086Supply calcium based high strength granular chlorination chemical (calcium hypochlorite having chlorine 65 % to 70%) for water treatement.Granular material shall be free of foreign material decomposing at 177 C soluble in water, not hygroscopic practically clear in water solution at saturation level. ..........\n1275Kg
11186.01............... The material should not contain more than 5% to 10% moisture. Granule size should be as follows:- Mesh passing through 100 BSS, 1.5 % Maximum iron as Fe 0.05% maximum Mn 40 PPM maximum MOL wt 142.98, Toxicity oral rate LD 50-850 mg/Kg duly tested from manufacture or authorised dealer/distributor complete all as specified and directed by Engineer-in-Charge.\n\n
11286.02Brand name/batch number and complete particulars of manufacturer should be printed on the container/packing.\n\nNote:- Demand of this granular is given in different lot at different time during the contract period as per requirement prior notice to contractor by Engr-in-charge \n\n

AI Tender Summary

OUR REF NO 25131803
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 18-08-2020
Authority
Authority Name Military Engineer Services
Work Description Repair/Maintenance Of External Water Supply , Submersible Pump Sets Etc . And Other Miscelleneous Works At Afs Samana
Basic Detail
Tender No 8734/E8
Bidding Type Tender
Location
City SAMANA
State Gujarat
Key Dates
Publish Date 10 Aug 2020
Submission Date 18 Aug 2020
Open Date 19 Aug 2020
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Not Available
Document List
Tendernotice_1.pdf
76C74C5C-B3D2-4591-9082-5AD3C6E9635E.html
PS_External_water_SUpply.pdf
BOQ_410683.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 10, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 19, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

76C74C5C-B3D2-4591-9082-5AD3C6E9635E.html

pdf

PS_External_water_SUpply.pdf

xls

BOQ_410683.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders