| Name of Work : WELCOME MAINT TO INTERNAL ELECTRIFICATION INCLUDING REPAIR TO GEYSER, FANS AND OTHER INTERNAL ACCESSORIES AT BEG AND CENTRE, TB-I AND DEP BN AND REPAIR/MAINT/PERIODICAL SERVICES OF DIESEL GENERATING SETS AND SOLAR SECURITY LIGHTS UNDER AGE E/M- I OF GE (C) KIRKEE. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed. | 390 | Point | |
| 2 | 2 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed. | 170 | Point | |
| 3 | 3 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed. | 240 | Point | |
| 4 | 4 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed. | 15 | Point | |
| 5 | 5 | M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket all as specified and directed. | 90 | Point | |
| 6 | 6 | M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 60 | RM | |
| 7 | 7 | M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 130 | RM | |
| 8 | 8 | M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 45 | RM | |
| 9 | 9 | M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. \nNOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 250 | RM | |
| 10 | 10 | M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. \nNOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. | 10 | RM | |
| 11 | 11 | S&F 5 Amp switch piano type single pole one way incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent | 910 | Each | |
| 12 | 12 | S&F 5 Amp switch piano type single pole two way incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent | 20 | Each | |
| 13 | 13 | S&F bell push piano type one way 240 volt incl dismentling taking down unsv one . all as specified and as directed. Make - Anchor or equivalent | 20 | Each | |
| 14 | 14 | S&F socket flush type 6 amps, 5 pin, 230v incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent | 470 | Each | |
| 15 | 15 | S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent | 90 | Each | |
| 16 | 16 | S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent | 110 | Each | |
| 17 | 17 | S&F lamp Holder insulated body with back plate for batten fitting incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent | 150 | Each | |
| 18 | 18 | S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips | 250 | Each | |
| 19 | 19 | S&F LED lamp 3 watt, CDL, E-14 cap, (Small thread type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips | 15 | Each | |
| 20 | 20 | S&F ceiling rose surface Bakelite three terminal incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent | 350 | Each | |
| 21 | 21 | S&F call bell electric, ding dong, AC 240 volt, 50 HZ. incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent | 20 | Each | |
| 22 | 22 | S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent | 160 | Each | |
| 23 | 23 | S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4085-87 to 4085-95 of Legrand or equivalent of Schneider/ABB. | 90 | Each | |
| 24 | 24 | S&F MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4086-28 to 4086-36 of Legrand or equivalent of Schneider/ABB\n | 30 | Each | |
| 25 | 25 | S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4087-00 to 4087-02 of Legrand or equivalent of Schneider/ABB\n | 10 | Each | |
| 26 | 26 | S&F Sheet metal enclosure two way, incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No-5077 91 to -5077 93 of Legrand or equivalent of Schneider/ABB. | 8 | Each | |
| 27 | 27 | S&F MCB distribution board,Double door, metal enclosure, SPN, 230 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 10 of Legrand or equivalent of Schneider/ABB | 8 | Each | |
| 28 | 28 | S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 11 of Legrand or equivalent of Schneider/ABB | 10 | Each | |
| 29 | 29 | S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts,12 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 12 of Legrand or equivalent of Schneider/ABB | 8 | Each | |
| 30 | 30 | S&F MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076-70 of Legrand or equivalent of Schneider/ABB | 4 | Each | |
| 31 | 31 | S&F Vertical MCB distribution board, as MCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5077-25 of Legrand or equivalent of Schneider/ABB | 1 | Each | |
| 32 | 32 | S&F Vertical MCB distribution board, as MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No-507745 of Legrand or equivalent of Schneider/ABB | 1 | Each | |
| 33 | 33 | S&F Metal plug and socket board with MCB SP 20 amp, 16 KA incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5078 11 of Legrand or equivalent of Schneider/ABB | 10 | Each | |
| 34 | 34 | S&F PVC rectangular switch board of size 300mmx 250mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza. | 15 | Each | |
| 35 | 35 | S&F PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza. | 25 | Each | |
| 36 | 36 | S&F PVC rectangular switch board of size 175mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza. | 25 | Each | |
| 37 | 37 | S&F PVC rectangular switch board of size 100mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza. | 20 | Each | |
| 38 | 38 | S&F Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Squar or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc incl dismentling taking down unsv one | 5 | Sqm | |
| 39 | 39 | S&F Round shaped recess mounted LED Flat panel down lighter, 12 watt (8\"dia), suitable for POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-Havells , Cat Part No LHEAABP7L1W012or equivalent in Bajaj/Philips/HPL/Havells | 8 | Each | |
| 40 | 40 | S&F LED tube 20 watt retrofit to existing fluorescent FTL (T-8) fitting surface mounted after dismentling electronic ballast, internal wiring and complete rewiring with 0.5 sqmm copper flexible conductor FRLSHom connector block to one end of Bipi holder and including connecting up to ceiling rose with 0.5 sqmm two core flexible copper conductor cable all as specified and directed. Make-Cat Part No HLPLEDT8PCP20CW HPL or equivalemt in Bajaj/Philips/Crompton Greaves /Havells | 300 | Each | |
| 41 | 41 | S&F industrial box type LED Batten with CRCA body, pre coated with white and prewired suitable for LED tube 1x18/20 watt 4'long incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No-HLPLEDT801WT or equivelent of Bajaj/Philips/CG/Havells | 280 | Each | |
| 42 | 42 | S&F LED batten tube type, 2'long, 09 watt,CDL 230 Volts , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL Cat Part No- HLPT51509PCGCW or equivalemt in Bajaj/Philips/CG/Havells | 40 | Each | |
| 43 | 43 | S&F LED fitting, 20 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No HPLLEDT5PC20W or equivalemt in Bajaj/Philips/CG/Havells | 180 | Each | |
| 44 | 44 | S&F LED building security light 15 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LSTP-15-CDL or equivalent in Bajaj/Philips/HPL/Havells | 35 | Each | |
| 45 | 45 | REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :-\nM&L for Rewinding of Ceiling fan 1200 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete. \nNote: 1. Contractor will collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for replacement such as bearing, Bushing, capacitor shall be measured and paid separately as supply & Fixing only. 3. Cost of Connector bock and capacitor holder shall be inclusive of the quoted rate. | 150 | Each | |
| 46 | 46 | All as per item No- 45 here-in-above but for Exhaust fan 250/300 mm sweep industrial type. | 20 | Each | |
| 47 | 47 | S&F ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC. | 390 | Each | |
| 48 | 48 | S&F G.M. Bush bearing for ceiling fan as per existing pattern. | 90 | Each | |
| 49 | 49 | S&F capacitor AC for 230 volts 50 Hz of capacity 1.8 Mfd. | 10 | Each | |
| 50 | 50 | S&F capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd. | 240 | Each | |
| 51 | 51 | S&F capacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd. | 5 | Each | |
| 52 | 52 | S&F capacitor AC for 230 volts 50 Hz of capacity 4.0 Mfd. | 15 | Each | |
| 53 | 53 | Painting of ceiling fan 1200/1400 mm including scrapping, cleaning and removing dust from the blade an body and applying two coat of enamel paint over & one coat of primer all as directed by engr-in-chage | 80 | Each | |
| 54 | 54 | S& F in repair of exhaust fand 300 mm PVC body, 230 vol incl dismentling taking down unsv fitting any type all as specified and directed. Make Bajaj or equivalent | 70 | Each | |
| 55 | 55 | S&F PVC insulated PVC sheathed copper flexiable wire multistrand 4sqmm 3 core, ISI marked | 20 | RM | |
| 56 | 56 | S&F in repair thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity. Make- Bajaj/Venus/Recold all as specified and directed. | 25 | Each | |
| 57 | 57 | S&F in repair fusible plug marked suitable for 25 and 50 ltrs capacity Geysers all as specified and directed. | 20 | Each | |
| 58 | 58 | S&F in repair heating elementMarked round/triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW all as specified and directed. | 20 | Each | |
| 59 | 59 | S&F in repair innner water container made of SS, vertical or horizontal type for 25/50 ltr capacity gyser all as specified and directed. | 8 | Each | |
| 60 | 60 | S&F in repair of aparatus plate suitable for vertical/horizintal type Geyser 25 or 50 ltr cap all as specified and directed. | 8 | Each | |
| 61 | 61 | S&F in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450mm long for hot /cold water all as specified and directed. | 15 | Each | |
| 62 | 62 | Maintenance and servicing of DG set 250 KVA,Make: Greaves Ltd including replacment of defective/wornout spares with new spares such as fuel filter, lube oil filter, gaskets, V belts,rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and replacement of Engine oil, tappet setting ,servicing of radiator etc for the smooth operation DG set all as specified and directed. Note: 1) Replacement of spares such as fuel filters and oil filter including Nut,bolts,washers,clamps, screws and grease etc required for the service / Maintenance of the DG Sets deemed to be included in the above quoted rate. 2) Other spares required for above will be measured and paid separately under relevent items of Sch. Location: Yerwada pump house. | 1 | Each Job | |
| 63 | 63 | All as item No.62 here in above but 110 KVA make kirloskar cummins installed at computer centre and indoor stadium at at BEG & Centre. | 2 | Each Job | |
| 64 | 64 | All as item No.62 here in above but 50 to 70 KVA make kirloskar installed at TB-II, ADG office, Rashmi and Sarvatra Vihar. | 4 | Each Job | |
| 65 | 65 | All as item No.62 here in above but 30 to 40 KVA make kirloskar installed at shooting gallery in Telephone exchange, TB-II, Kekdi Line and Nirikshan Vihar. | 5 | Each Job | |
| 66 | 66 | All as item No.62 here in above but 15 to 25 KVA make kirloskar installed at TB-I Pump House,Depot Bn Pump House Baffle Range ,Depot Bn sub stn and Engine House Road. | 5 | Each Job | |
| 67 | 67 | Supply only Air filter inner and outer for 250 KVA DG set Greaves Ltd\n | 1 | Set | |
| 68 | 68 | Supply only Air filter inner and outer for 100 to110 KVA DG set Kirloskar cummins.\n | 2 | Set | |
| 69 | 69 | Supply only Air filter inner and outer for 50 to 70 KVA DG set Make:Kirloskar. | 5 | Set | |
| 70 | 70 | Supply only Air filter inner and outer for 30 and 40 KVA DG set, Make :Kirloskar | 4 | Set | |
| 71 | 71 | Supply only Air filter inner and outer for 15 to 25 KVA DG set Make: Kirloskar or equivalent | 5 | Set | |
| 72 | 72 | Supply only Fan belt for 250 KVA DG set,Make :JK/Dunlop | 1 | Each | |
| 73 | 73 | Supply only Fan belt for 110 to 110 KVA DG set, Make :JK/Dunlop | 2 | Each | |
| 74 | 74 | Supply only Fan belt for 50 to 70 KVA DG set,Make : JK/Dunlop | 5 | Each | |
| 75 | 75 | Supply only Fan belt for 30 to 40 KVA DG set,Make : JK/Dunlop | 4 | Each | |
| 76 | 76 | Supply only Fan belt for 15 to 25 KVA DG set, Make : JK/Dunlop | 5 | Each | |
| 77 | 77 | Supply only Fuel actuator with O Ring for 250 KVA DG set,Make : Greaves | 1 | Each | |
| 78 | 78 | Supply only Fuel actuator with O Ring for 100 to 110 KVA DG set,Make : Kirloskar | 1 | Each | |
| 79 | 79 | Supply only Fuel actuator with O Ring for 50 to 70 KVA DG set,Make : Kirloskar | 2 | Each | |
| 80 | 80 | Supply only ignition switch with Key for 110 KVA DG set,Make : Kirloskar | 1 | Each | |
| 81 | 81 | Supply only ignition switch with Key for 40 to70 KVA DG set,Make : Kirloskar | 3 | Each | |
| 82 | 82 | Supply only coolant temperature sensor with guage for 100 KVA to 250 KVA DG set. | 2 | Each | |
| 83 | 83 | Supply only coolant temperature sensor with guage for 15 KVA to 70 KVA DG set. | 5 | Each | |
| 84 | 84 | Supply only Lube oil pressure sensor ( Oil safety control ) for 100 to 250 KVA DG set. | 2 | Each | |
| 85 | 85 | Supply only Lube oil pressure sensor ( Oil safety control ) for 50 to 70 KVA DG set. | 3 | Each | |
| 86 | 86 | Supply only Lube oil pressure sensor ( Oil safety control ) for 30 to 40 KVA DG set. | 2 | Each | |
| 87 | 87 | Supply only Lube oil pressure sensor ( Oil safety control ) for 15 to 25 KVA DG set. | 4 | Each | |
| 88 | 88 | Supply only Hose set with clamps and screws suitable for DG set 250 KVA make: Greaves Ltd. | 1 | Each | |
| 89 | 89 | Supply only Hose set with clamps and screws suitable for DG set 100 KVA to 110 KVA make: Kirloskar. | 2 | Each | |
| 90 | 90 | Supply only Hose set with clamps and screws suitable for DG set 50 to 70 KVA make: Kirloskar. | 3 | Each | |
| 91 | 91 | Supply only Hose set with clamps and screws suitable for DG set 30 to 40 KVA make: Kirloskar. | 3 | Each | |
| 92 | 92 | Supply only Hose set with clamps and screws suitable for DG set 15 to 25 KVA make: Kirloskar. | 4 | Each | |
| 93 | 93 | Supply and replacement of self starter 12 volt dc including testing and commissioning as all specified and directed. Make :- Lucas/Mico | 3 | Each | |
| 94 | 94 | Supply and replacement of self starter 24 volt dc including testing and commissioning as all specified and directed. Make :- Lucas/Mico | 1 | Each | |
| 95 | 95 | Supply and Replacement of battery box made out to shape with angle iron 40x40x 5 mm, size 40cm x40cm x 20cm (Internal ) to arrange existing batteries all as directed. | 4 | Each | |
| 96 | 96 | Supply and Replacement of heavy duty battery terminals Brass with copper lead Pvc insulated multi stranded 25 sq mm duly soldered for +ve and -ve,05 mtr to 1.2 mtr long for 12/ 24 volt batteries. | 10 | Each | |
| 97 | 97 | Supply and fixing heating proof asbestos rope 12 mm dia on engine exhaust pipe including dismantling of burn out asbestors rope and arresting all leakages by welding / tightening the exhaust line including aluminium cladding and making complete fire proof, flame proof all as specified and directed. | 100 | Kg | |
| 98 | 98 | Preparation of old painted surface of the DG Set installed in acuastic enclosure including Base frame, radiator ,Fuel tank etc of the following capacities complete degreasing and spray painting the same with two coats of approved synthetic enamel paint including writing SM/MES nos,Desriptions,Location,Capacity etc on DG set size of letter shall be 5 CMx5CM of capacity 15 KVA to 70 KVA all as directed by Engr in Charge . | 3 | Each Job | |
| 99 | 99 | Preparation of old painted surface of the DG Set including Base frame, radiator, Fuel tank etc of the following capacities complete degreasing and spray painting the same with two coats of approved synthetic enamel paint including writing SM/MES nos,Description,Location,Capacity etc on DG set size of letter shall be 5CMx5CM of capacity 100 KVA to 250 KVA all as directed by Engr in Charge. | 3 | Each Job | |
| 100 | 100 | Supply and replacement of Anti vibration pad as per existing size and make all as directed by Engr-in-charge. | 24 | Each | |
| 101 | 101 | Descaling,Cleaning and pressure testing of radiator assembly as required including Brazing etc complete to make leak proof of capacity 15 KVA to 70 KVA all as directed by the Engr-in-charge. | 14 | Each | |
| 102 | 102 | Descaling,Cleaning and pressure testing of radiator assembly as required including Brazing etc complete to make leak proof of capacity 100 KVA to 250 KVA all as directed by the Engr-in-charge. | 3 | Each | |
| 103 | 103 | Supply & Fix solonoid switch 12 Volts all as specified and and directed | 4 | Each | |
| 104 | 104 | Supply & Fix solonoid switch 24 Volts as specified and and directed | 1 | Each | |
| 105 | 105 | Supply & Fix in replacement/ Topping up of Coolent for radiators as approved by the Engr-In-Charge. Make Bosch | 100 | Ltrs | |
| 106 | 106 | Supply & Fix Oil pressure gauge for 100 KVA to 250 KVA all as specified and and directed | 2 | Each | |
| 107 | 107 | Supply & Fix Oil pressure gauge for 15 KVA to 70 KVA all as specified and and directed. | 6 | Each | |
| 108 | 108 | Supply and Replacement of hour run meter with hour counter. | 4 | Each | |
| 109 | 109 | Supply and filling / Topping up engine oil multi grade as per manufacturers Recommendations in engine all as specified and directed. (Make ELF Oil/ Castrol /HP) including draining out old and burned engine oil. | 370 | Ltrs | |
| 110 | 110 | Overhauling of FIP (Fuel Injection Pump) at work shop including replacement of small spares required,complete setting and pressure testing at work shop to make the FIP and injectors functional for DG set 100 KVA to 250 KVA all as specified and directed. | 2 | Each Job | |
| 111 | 111 | Overhauling of FIP ( fuel injection pump ) at work shop including replacement of small spares required,complete setting and pressure testing at work shop to make the FIP and injectors functional for DG set 15 KVA to 70 KVA all as specified and directed. | 5 | Each Job | |
| 112 | 112 | Supply and Replacement of locks and keys for aquastic enclosures as per samples. | 10 | Each | |
| 113 | 113 | Supply and Replacement of control pannel complete suitable for 15 KVA to 70 KVA DG Set. | 2 | Each | |
| 114 | 114 | Supply and Replacement of AVR (automatic voltage regulator ) suitable for DG set 100 KVA to 250 KVA. | 1 | Each | |
| 115 | 115 | Supply and Replacement of AVR (automatic voltage regulator ) suitable for DG set 50 KVA to 70 KVA. | 2 | Each | |
| 116 | 116 | Supply and Replacement of AVR (automatic voltage regulator ) suitable for DG set 15 KVA to 40 KVA. | 5 | Each | |
| 117 | 117 | M& L for rewinding,varnishing & insulation & drying of AC alternator stator including transportation from site to wksp and back. | 250 | Per KVA | |
| 118 | 118 | M& L for winding, Varnishing and insulation of rotor including trasportation from site to wksp and back. | 250 | Per KVA | |
| 119 | 119 | S& F DG set controller, Model No ACG 543 all as specified and and directed. | 2 | Each | |
| 120 | 120 | S&F fuel hose for any capacity DG set 1 mtr to 2 mtr for fuel tank to DG set all as specified and and directed. | 15 | RM | |
| 121 | 121 | M & labour for calibration of fuel feed pump for any capacity of DG set. | 8 | Each | |
| 122 | 122 | S&F 4 pole power contactor, 415Volts, 60 amps, , incl dismentling taking down unsv one, Make-L&T, Type-ML-3, Cat No-SS90721 or equivelent model of ABB/Schneider | 4 | Each | |
| 123 | 123 | S&F 4 pole power contactor, 415Volts, 100 to 160 amps, , incl dismentling taking down unsv one, Make-L&T, Type-ML-3, Cat No-SS90721 or equivelent model of ABB/Schneider | 3 | Each | |
| 124 | 124 | S& F SMPS 12 vots 10 amp for 15 to 70 KVA DG set | 6 | Each | |
| 125 | 125 | S& F SMPS 24 volts 10 amp 100 to 250 KVA DG set | 2 | Each | |
| 126 | 126 | S&F rectifier diode assembly 15 to 70 KVA DG set | 6 | Each | |
| 127 | 127 | S&F rectifier diode assembly 100 to 250 KVA DG set | 3 | Each | |
| 128 | 128 | Repair of turbocharging with repair Kit 100 to 250 KVA DG set | 2 | Each | |
| 129 | 129 | Repair of turbocharging with repair Kit 15 to 70 KVA DG set | 6 | Each | |
| 130 | 130 | Removing old unserviceable battery charging unit from DG Set of 50 to 70 KVA of any make & supply & fixing battery charging unit 12 volt of the same type with all necessary modifications including all fittings such as pully , belt , cables hardwares etc including fixing testing & commissioning complete all as specified & directed. | 1 | Each Job | |
| 131 | 131 | M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing strip of 25x4 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion. | 28 | Each Set | |
| 132 | 132 | PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of DG set, Panel board, repairs to road cutting, drain, path etc complete all as specified and directed. | 16 | Cum | |
| 133 | 133 | PCC (1:2:4) type B-1 using 20mm graded aggregate a of reconstruction old damaged copings of DG set/ panel etc, including necessary form work complete all as specified and directed. | 10 | Cum | |
| 134 | 134 | Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 16 sqmm 4 core with required aluminium cable lugs. | 140 | RM | |
| 135 | 135 | All as per item No.134 here-in-before but 25sqmm 3,5 core complete all as specified | 160 | RM | |
| 136 | 136 | All as per item No.134 here-in-before but 50sqmm 3.5 core complete all as specified | 120 | RM | |
| 137 | 137 | Supply and fix in repair of air valve and pressure valve of solar water heater | 10 | Each | |
| 138 | 138 | Supply and fix in repair of holding rubber of glass tube of ETC solar water heater. Make : Photon/Tata | 10 | Each | |
| 139 | 139 | Supply and fix in repair of silicon coated glass tube set of ETC solar water heater. Make : Photon/Tata | 5 | Set | |
| 140 | 140 | Supply and fix in repair of silcon coated plate of FPC solar water heater. Make : Photon/Tata | 4 | Set | |
| 141 | 141 | Supply and fix in repair of ETC Solar Glass singleTube with holding rubber, for Hot Water. Make : Photon/Tata | 10 | Each | |
| 142 | 142 | Supply and fix in repair of 100 ltr corrosion resistance insulated tank of Solar Water heater. Make : Photon/Tata | 3 | Each | |
| 143 | 143 | Supply and fix in repair of 200 ltr corrosion resistance insulated tank of Solar Water heater . Make : Photon/Tata | 3 | Each | |
| 144 | 144 | Supply and fix in repair of 300 ltr corrosion resistance stainless steel tank of Solar Water heater . Make : Photon/Tata | 3 | Each | |
| 145 | 145 | Supply and fix in repair of heating element 2 KW to 3 KW for electricity back up | 10 | Each | |
| 146 | 146 | Supply and fix in repair of rubber pipe with clamp dia15 to 20 mm and length 0.5 mtr | 16 | Each | |
| 147 | 147 | Supply and fix in repair of tubular power pack 12 volts, 80 to 100 Ah suitable for solar street light. | 7 | Each | |
| 148 | 148 | Supply and fix in repair of tubular power pack 12 volts, 48 to 70 Ah suitable for solar street light. | 6 | Each | |
| 149 | 149 | Supply and fix in repair of solar battery charging module suitable for 110 wp solar street light pannels. | 18 | Each | |
| 150 | 150 | Supply and fix in repair of LED lamp15 Watt suitable for solar street light. | 20 | Each |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy