Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #25122987

Special Repair To Retaining Wall And Provision Of Parking Shed , Mt Shed , Septic Tank And Soak Well At Various Location In Rms

Issued by Statutory Bodies & Commissions/Committees · Rangapahar, Nagaland
Tender Value
25.71 Lakhs
Estimated cost
Bid Submission
18 Aug 2020
0 days left
EMD
51500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rangapahar → Nagaland
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Special Repair To Retaining Wall And Provision Of Parking Shed , Mt Shed , Septic Tank And Soak Well At Various Location In Rms

BOQ

Name of Work: SPL REPAIR TO RETAINING WALL AND PROVN OF PARKING SHED, MT SHED, SEPTIC TANK AND SOAK WELL AT VARIOUS LOCATION IN RMS
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Demolition of brick work/stone masonry built in cement mortar or cement lime mortar including all quoins, arches etc completeBI01010001010000000000000515BI010000111314.3Cum
22Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level.BI01010001010000000000000515BI010000111411.4Cum
33Surface excavation n exc 30 cm deep and average 15 cm deep and getting out soft and loose soil.BI01010001010000000000000515BI0100001115222Sqm
44Excavation over areas n.exc 1.5m deep & getting out soft/loose soil.BI01010001010000000000000515BI010000111622Cum
55Excavation over areas exc 1.5m deep & n.exc 3 m deep and getting out in soft/loose soilBI01010001010000000000000515BI010000111718Cum
66Excavation of post holes (or similar holes) each n.exc 0.5 cum getting out returning filing in and ramming earth or broken ruble mixed with earth around in layer n exc 25 cm and getting out soft/loose soil.BI01010001010000000000000515BI010000111825Each
77M &L for excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundation ,getting out soft/loose soil. \nBI01010001010000000000000515BI010000111936Cum
88Returning filling in including spreding, leveling, watering, and well ramming in layer n exc 25 cm and getting out soft/loose soil.BI01010001010000000000000515BI010000112037Cum
99Removing excavated material exc 250 m but n exc 500 and deposting where directed.BI01010001010000000000000515BI010000112185Cum
1010M&L for brocken stone or boulders hardcore of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surfaces all as specified and directed.BI01010001010000000000000515BI010000112227Cum
1111M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone) as in filling and mass concrete.BI01010001010000000000000515BI01000011234.5Cum
1212M&L PCC 1:4:8 type D-2 75mm thick as in sub base of floor.BI01010001010000000000000515BI010000112583Sqm
1313M & L 100 mm th PCC 1:3:6 type C-2 as in floor, finished even and fair complete all as specified.BI01010001010000000000000515BI0100001126119Sqm
1414M&L for 100 mm thick cement concrete in sub base type D-2, 1:4:8 (40 mm graded aggregate) all as specified and directed.BI01010001010000000000000515BI010000112736Sqm
1515M&L PCC 1:3:6 Type C-2 (using 40mm graded stone aggregate) as in plinth protection, foot path, paved area, etc finished even and fair without using extra cement 75mm thick complete all as specified and directed.BI01010001010000000000000515BI010000111457Sqm
1616M & L PCC 1:3:6 type C-2 s(using 40mm grade stone aggregate as in foundation etc and mass concrete.BI01010001010000000000000515BI01000011157.5Cum
1717M & L for PCC (1:3:6) type C-2 using 40mm graded aggregate as bond stone including necessary form work complete all as specified.BI01010001010000000000000515BI01000011163.35Cum
1818M & L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in coping including necessary form work all as specified and directedBI01010001010000000000000515BI01000011170.4Cum
1919M&L 100mm thick Cement concrete 1:2:4 type B- 2, (40mm graded aggregate) as in floor finishedBI01010001010000000000000515BI010000111832Sqm
2020PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in channels of man holes.BI01010001010000000000000515BI01000011190.45Cum
2121PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in band coping bed plate, benching etc including slightly rounded of chamfered angle, throating, etc complete all as specified and as directed.BI01010001010000000000000515BI01000011200.4Cum
2222Precast RCC (1:2:4) type B-1 in manhole/soack well/septic tanks slabs/covers etc including necessary form work complete set in cement mortar 1:6 complete.BI01010001010000000000000515BI01000011210.5Cum
2323M&L Cement concrete 1:3:6 type C-1 (20 mm graded agg ) in surface channels and drains.BI01010001010000000000000515BI01000011223.1Cum
2424Material and labour Reinforced cement concrete (Nominal Mix) in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes, septic tanks, soakage wells etc. complete all as specified & as directed by Engineer-in-charge.\nNote: - Reinforcement shall be measured and paid for separately.BI01010001010000000000000515BI01000011230.8Cum
2525Extra for forming fair finished surfaces of drain or channels, inner girth 30 cms, using extra cement including forms, moulds mitred/ stopped ends etc., complete.BI01010001010000000000000515BI010000112551RM
2626S/F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws all as specified and as directed.BI01010001010000000000000515BI0100001126226Sqm
2727S & F 0.50mm thick pre-painted galvalume aluminiun zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall , ridge and velly complete all as specified and directed.BI01010001010000000000000515BI010000112730Sqm
2828M& L for brick work with sub class B brick straight or curved on plan exc 6.00 m mean radius built in cement morter 1:6.BI01010001010000000000000515BI010000111432.75Cum
2929M&L brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4BI01010001010000000000000515BI010000111529Sqm
3030Material and labour for brickwork in cement mortar 1:6 with sub class `B' bricks in one brick thick honey comb walling,etcBI01010001010000000000000515BI01000011167.64Sqm
3131Material and labour for brick work in cement mortar 1:4 with sub class `B' bricks straight or curved on plan exceeding 6m mean radius with old size bricks as in pillars complete all as specified.BI01010001010000000000000515BI010000111721Cum
3232M&L for rendering 10 mm thick on other than fairs surfaces of brick wall in cm 1:6 in on wall.BI01010001010000000000000515BI0100001118135Sqm
3333M & L rendering 15mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement.BI01010001010000000000000515BI010000111957Sqm
3434M & L rendering 15mm thick on cement mortar 1:4 brick or concrete work finished the surface even and smooth without using extra cement..BI01010001010000000000000515BI0100001120135Sq.m
3535M&L for rendering 5mm thick plaster in CM 1:3 on fair faces of brick or concrete work finished even and smooth without using extra cement as in ceiling.BI01010001010000000000000515BI01000011215Sqm
363615mm thick cement plaster in cement mortar (1:4) on brick or concrete surface mixed with water proofing compound as per manufactures instructions, finishing the surface even and smooth without using extra cement complete all as specified.BI01010001010000000000000515BI010000112226.88Sqm
3737Supply only integral water proofing compound (ISI marked)BI01010001010000000000000515BI01000011237.48Kg
3838S&F dividing strip 30 mm width and 3 mm thick inserted in position confirmed to design.BI01010001010000000000000515BI010000112524RM
3939M & L for walling of random rubble, uncoursed well bounded bedded and solidly hearted, built in CM (1:6) including provision of weep holes complete all as specified and directed.BI01010001010000000000000515BI010000112699Cum
4040All as per ser No 39 here-in-before but except stonesBI01010001010000000000000515BI01000011275Cum
4141M&L for raised pointing to random or polygonal rubble uncoursed or brought up to course in CM (1:4) complete all as specified and directed.BI01010001010000000000000515BI01000011146Per 10 Sqm
4242Mild steel TMT round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips including two coat of bituminous paint.BI01010001010000000000000515BI01000011151170Kg
4343TMT Steel bars 6 to 8mm dia, cut to length bent to shape required including cranking bending spirally or hopping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified.BI01010001010000000000000515BI010000111680Kg
4444All same as per item No 43 above but 5mm dia.BI01010001010000000000000515BI0100001117450Kgs
4545Cutting into existing manhole/soakwell/septic tank making good to pipe and benching cutting out existing benching for and forming branch channel (half round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for internal dia size 150mm.BI01010001010000000000000515BI01000011182Each
4646Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)BI01010001010000000000000515BI010000111933Sqm
4747Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter.BI01010001010000000000000515BI010000112068Sqm
4848Use and waste of formwork to sides of pillars posts, struts, piers, columns and stanchions finished the suface rough.BI01010001010000000000000515BI010000112167Sqm
4949Use and waste of formwork to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc.BI01010001010000000000000515BI010000112231.3Sqm
5050Use and waste of formwork to chajjas, troughts and similar items including edges.BI01010001010000000000000515BI01000011235.5Sqm
5151M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams; plinth beams; bases for coloumns, etc basement slabs under reamed piles and mass concrete.BI01010001010000000000000515BI010000112511.2Cum
5252M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate)as in columns, pillars, piers, posts and struts.BI01010001010000000000000515BI01000011264.2Cum
5353M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.BI01010001010000000000000515BI01000011272.3Cum
5454M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate) as in chajjas.BI01010001010000000000000515BI01000011140.82Cum
5555M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate) as in beams, cantilvers, bressummers, lintels over 1.5m span.BI01010001010000000000000515BI01000011153.12Cum
5656S&F for steel work in tabular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S.1161-1998 grade St- 240 all as specified and directed.BI01010001010000000000000515BI01000011162127Kg
5757S&F for post of Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming Fe 410 -W (Gde- E- 250) quality- ABI01010001010000000000000515BI0100001117188Kg
5858Roof trusses (framed), trussed, purlins, crane gantries, rails,posts and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etcBI01010001010000000000000515BI0100001118420Kg
5959S&F MS plate 6mm thick (Plain or chequred) ,channels, and counter sank forming holes, with out any attachment FE-410-W (Code E - 250) Quality - BBI01010001010000000000000515BI010000111910Kg
6060S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde E-165.BI01010001010000000000000515BI010000112095Kg
6161S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.BI01010001010000000000000515BI010000112124Kgs
6262Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe290 Gde-E-165.BI01010001010000000000000515BI010000112298Kg
6363Mild steel, plain black sheet 1mm thick in wall cladding, steel gates and similar work, cut to size holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams all as specified and as directed.BI01010001010000000000000515BI01000011235.2Sqm
6464S&F steel windows with side hung shutters including Box type hinges with steel handle and steel peg stay, complete with glazing bars, devetailed or welded.BI01010001010000000000000515BI01000011257.9Sqm
6565S&F 3mm thick figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 Sq.m in each pane.BI01010001010000000000000515BI01000011266.5Sqm
6666M&L of sand filling under floor well ramming including watering as required Spreading & leveling in layers n.exc. 25cm thickBI01010001010000000000000515BI010000112719.85Cum
6767M&L, providing Kota stone slab 20 to 25mm thick machine cut and mirror polished to size and fixed in floor and set and jointed in neat cement slurry and pointed with grey cement to match the stone floor/steps treads over 15mm thick screed bed in CM 1:6 complete all as specified and directed.BI01010001010000000000000515BI010000111483Sqm
6868M&L, providing Kota stone slab 20 to 25mm thick machine cut and mirror polished to size and fixed in wall and set and jointed in neat cement slurry and pointed with grey cement to match the stone over and including 10 mm thick rendering in CM 1:4 for laying in vertical surfaces complete all as specified and directed.BI01010001010000000000000515BI01000011155.7Sqm
6969M/L for factory made 80 mm thick precast cement concrete interlocking tile paver blocks of grade M-40 of size and shape as directed such as I-shape , Uni, Octagonal, Three-X, Dumble , zig, zaj etc , laid over and incl 50 mm thick sand custion (local Tibba sand ), laid dry , joints filled with dry sand complete all as specified and directed by EIC (Note : sand will be measured separetly).BI01010001010000000000000515BI010000111675Sqm
7070S&F Plates (plain or chequered) channels. Square cut or notched ) (ordinary and counter sunk) forming holes, without any attachment of Fe-410-W (Gde-E-250 quality-A)BI01010001010000000000000515BI010000111745Kg
7171S&F bands, straps or stays , plain angle cleat or flat iron cleat or securing purlins to wood trusses or rafters, knee piece and similar small articles etc conforming to Fe-290 Gde E-165.BI01010001010000000000000515BI010000111812Kg
7272S&F PVC (SWR) 110mm dia junction single T equal or un equalwith an floorBI01010001010000000000000515BI01000011192Each
7373S&F PVC (SWR) 110mm dia bends in any radius.BI01010001010000000000000515BI01000011202Each
7474S&F PVC (SWR) 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floor.BI01010001010000000000000515BI01000011215RM
7575S&F PVC (SWR) 75mm dia vent cowlBI01010001010000000000000515BI01000011222Each
7676S&F for 110 mm dia PVC (SWR) pipe single socketed in any length with rubber joints laid in trenches/floor/weep holes and similar work all as specified.BI01010001010000000000000515BI0100001123182Rm
7777M&L for preparation of new plastered surfaces and applying three coats of white wash on walls all as specified & directed by Engineer-in-ChargeBI01010001010000000000000515BI0100001125125Sqm
7878M&L for preparation of new wall surface and two coats of cement base paint on walls.BI01010001010000000000000515BI0100001126135Sqm
7979M&L for preparation of new ceiling surface and two coats of cement base paint on ceiling.BI01010001010000000000000515BI01000011275Sqm
8080M&L for preparation of new steel surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paints over one of red oxide primer all as specified as directed.BI01010001010000000000000515BI0100001114123Sqm
8181M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connecting to earth dolly, including PVC rectangular box for mounting switches/sockets/regulators etc. with 3mm thick plastic laminated sheet cover of suitable size as required at site and 50 mm deep complete all as specified and as directed.Make:- Finolex/Richa/RR Kabel Make of caping/casing & PVC boxes :- Prestoplast/Finolex/supreme/RichaMake: finolex/Havells/RR Kabel. Make of caping/casing & PVC boxes: Prestoplast/finolex/Supreme.BI01010001010000000000000515BI01000011151rm
8281.01One light/fan point controlled by one, one way switch.BI01010001010000000000000515BI01000011163Point
8381.02One light point/fan point controlled one way each addition light point on the same switch circuitBI01010001010000000000000515BI010000111715Point
8481.03One 3 pin socket outlet 5 Amps on the independent board.BI01010001010000000000000515BI01000011182Point
8582All as per item No.81 here-in-before but with 2.5 Sqmm for 3 pin 15 Amps switch socket point on independent board along with one run of 2.5 Sqmm copper conductor green in colour as earth continuity conductor connected to earth dolly complete all as specified and as directed.BI01010001010000000000000515BI01000011191Point
8683M&L for Switch Piano, flush type single pole, one way 5 Amps complete all as specified and directed. \nMake:-Anchor/Plaza/SSKBI01010001010000000000000515BI010000112020Each
8784M&L for Socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed.\nMake :Anchor/Plaza/SSKBI01010001010000000000000515BI01000011212Each
8885M&L for Switch Socket combination 2 in 1, 3 pin 5A/16A, 5 in 1 flush complete all as specified and directed. \nMake :Anchor/Plaza/SSKBI01010001010000000000000515BI01000011221Each
8986M&L for stepped type electronic fan regulator 100 watt socket size flush type on the existing phenolic laminatied sheet etc. \nMake :Anchor/Plaza/SSKBI01010001010000000000000515BI01000011234Each
9087M&L for ceiling rose 3 terminal PVC/ Polycarbonate isolated body with PVC round/squareblock complete all as specified and directed.\nMake :Anchor/Plaza/SSKBI01010001010000000000000515BI010000112514Each
9188M&L for 20W LED, 4', Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and as directed.\nMake : Havells Cat No LHFYBYPNIA1W022(batten) & LHLDDCXCML8P020(LED Tube) or equivalent in Bajaj/Philips Make : Havells Cat No LHFYBYPNIA1W022 Regal (batten) & LHDLEFXD5LR020(LED Tube) or equivalent in Bajaj/PhilipsBI01010001010000000000000515BI01000011266Each
9289M&L for Lamp holder , PVC/ Polycarbonate type with PVC round/square block incl 9 watt LED lamp suitable for lamp holder fittings. \nMake :- Plaza/SSK/Anchor Make of Lamp :- Havells/Bajaj/PhilipsBI01010001010000000000000515BI01000011274Each
9390M&L for LED 1x20W building Security light fitting, drawn through including GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling holes as required and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and directed. \nMake:-Endurapearl SL20WLLED757SASYTOPCMP /Bajaj/Philips/CGMake:-Havells Cat Pt No LHETBXU7PA6S020 or equivalent in Bajaj/PhilipsBI01010001010000000000000515BI01000011142Each
9491S&F for Ceiling fan 1200 mm sweep, 5 star rating including suitable size of fan hook and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed.\nMake : Usha/Bajaj/CGBI01010001010000000000000515BI01000011154Each
9592S&F for fixing Exhaust fan, Metallic, AC single phase 230/ 240 volts of size 300 mm sweep with louvre shutter including anchor bolt of suitable size for fixing arrangement and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed.\nMake : Bajaj/CG/HavellsBI01010001010000000000000515BI01000011162Each
9693M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder coated, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. \nMake:- Legrand Cat No 507711 or equivalent in ABB/SiemensBI01010001010000000000000515BI01000011171Each
9794M&L for MCB SPN, 40 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down complete all as specified and as directed. \nMake: Legrand Cat No 408636 or equivalent in ABB/Siemens.BI01010001010000000000000515BI01000011181Each
9895M&L for MCB SP, 5 to 32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed. \nMake:- Legrand Cat No 408587-95 or equivalent in ABB/SiemensBI01010001010000000000000515BI01000011196Each
9996Taking down LT UG cable/service connection of any size and M&L for laying of LT UG cable , XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. \nMake: Richa/Polycab/PhinolexBI01010001010000000000000515BI010000112030RM
10097M&L for fine river washed sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken.BI01010001010000000000000515BI01000011211.35Cum
10198M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directedBI01010001010000000000000515BI0100001121173.91Each
10299Supply and laying tubes light grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 40mm dia bore including taking out unsv GI tubing complete all as specified and as directed. \nMake: Jindal/Prakash surya/TATABI01010001010000000000000515BI01000011226RM
103100M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed.\n(i) The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 with 10mm thick CI cover plate hinged to angle iron frame of suitable size, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (iii) Test points shall be made of GI strip 32x6 mm bridge type.BI01010001010000000000000515BI01000011281Each Set

AI Tender Summary

OUR REF NO 25122987
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25.71 Lakhs
LAST DATE 18-08-2020
Authority
Authority Name Military Engineer Services
Work Description Special Repair To Retaining Wall And Provision Of Parking Shed , Mt Shed , Septic Tank And Soak Well At Various Location In Rms
Basic Detail
Tender No 8333/E8
Bidding Type Tender
Location
City Rangapahar
State Nagaland
Key Dates
Publish Date 10 Aug 2020
Submission Date 18 Aug 2020
Open Date 20 Aug 2020
Finance
Tender Value 25.71 Lakhs
Tender Fee 500
EMD 51500
Exemption Not Available
Document List
BOQ_410439.xls
Tendernotice_1.pdf
tender_doc.pdf
F42581C0-571B-4D07-B8B8-7459A1093964.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 10, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 20, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_410439.xls

pdf

Tendernotice_1.pdf

pdf

tender_doc.pdf

html

F42581C0-571B-4D07-B8B8-7459A1093964.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders