Provision Of Emergency Bell Installed From New Armoury To Main Guard Room , Dsc Guard Rest Room , Orderly Officer Restroom And Provn Geysers To Certain Smqs And Certain Minor Works At Af Station Yelahanka, AFS Yelahanka-Karnataka

Military Engineer Services-MES has published Provision Of Emergency Bell Installed From New Armoury To Main Guard Room , Dsc Guard Rest Room , Orderly Officer Restroom And Provn Geysers To Certain Smqs And Certain Minor Works At Af Station Yelahanka. Submission Date for this Tender is 26-08-2020. Geyser Tenders in AFS Yelahanka Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

25113018
Corrigendum : Provision Of Emergency Bell Installed From New Armoury To Main Guard Room , Dsc Guard Rest Room , Orderly Officer Restroom And Provn Geysers To Certain Smqs And Certain Minor Works At Af Station Yelahanka
Open Tender
Indian
Karnataka
AFS Yelahanka
26-08-2020

Tender Details

Provision Of Emergency Bell Installed From New Armoury To Main Guard Room , Dsc Guard Rest Room , Orderly Officer Restroom And Provn Geysers To Certain Smqs And Certain Minor Works At Af Station Yelahanka

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Aug-2020 revised tender documents Financial Bid 26-08-2020
2 14-Aug-2020 Corrigendum Financial Bid 26-08-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 53200.0 /-
Tender Value
INR 26.60 Lakhs /-

BOQ Items

Name of Work:PROVISION OF EMERGENCY BELL INSTALLED FROM NEW ARMOURY TO MAIN GUARD ROOM,DSC GUARD REST ROOM, ORDERLY OFFICER RESTROOM AND PROVN GEYSERS TO CERTAIN SMQS AND CERTAIN MINOR WORKS AT AF STATION YELAHANKA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil. 221.94 CUM
2 2 Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete. 52.5258 CUM
3 3 Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed. 169.414 CUM
4 4 Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm 5480 Each
5 5 Supply, lay, spread in trenches river sand including spreading, levelling, punning for cushioning of cable all as specified and as directed.\nNote:- For payment purpose,only punned thickness shall be considered.. 66.582 Cum
6 6 Boring of holes under road, pavement, hardstandinig by trenchless technology using ultrasound technique and necessary maching including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure. 80 RM
7 7 M&L earthing complete with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with GI earth wire of 4 mm dia up to a length of 7.5 mtr long by means of GI bolts, nuts,washers etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connecting to test point, all as shown in electrical plate No.3 of SSR Part I incl necessary earth work and excavation in any type of soil, PCC(1:3:6) type C1 earth chamber with RCC cover slab 50 mm thick,with RCC (1:2:4) type B1 with 8 mm CTD bars re -inforcement both ways at 140 mm C/C with MS hook,including salt, charcoal and provn of test point complete all as spcified and directed by Engr-in-Charge, 4 Each
8 8 Supply and fixing cable route indicator made out of 3 mm thick ms sheet of size 20 cm x 15 cm duly painted with two coats black paint over a coat of red oxide primer and writing HT/LT cable, direction & size of cable with white paint, mounted on angle iron 40x40x3 mm, angle of height 45 cm, (30cm below ground level) duly grouted in PCC block of size 20cmx20cmx15cm including neccessary earth works . 22 Each
9 9 Supply and laying in trenches, LT underground cable of size 4 core 16 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-Charge. 1370 Each
10 10 Suppl and fix GI tube light grade of dia 40mm incl fixing of necessary clamps for protection of cable laying and fixed to walls/pole etc. all as specified and directed. 50 RM
11 11 Supply and fix gong bell single phase 220V AC aluminium cast iron body and weather proof provided with chromium weather proof provided with chromium mild steel pressed gong 12". Make - Edison or equivalent as approved by GE. 6 Each
12 12 Supply and fix switch, 15 amps incl bakelite sheet 3 mm thickness alongwith MS box flushed inside the wall suitable for controlling the bell all as specified and directed. 3 Each
13 13 Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge. 1 Each
14 14 Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 2 way SIngle door flushed inside the wall without bus bar including flushing the DBs inside the walls and making good the disturbed surface also matching with the existing surface complete all as specified and directed by Engr in charge. 72 Each
15 15 Supply and fix MCB Triple pole and Neutral , 415 volts, 20 to 32 Amps 10 KA, all as specified and as directed. 2 Each
16 16 Supply and fix MCB Single pole & neutral 240 volts, 5 to 30 Amps 10 KA all as specified and as directed. 5 Each
17 17 Sub main wiring complete with two runs of 4.0 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed FRLS cable 1100 volts grade, multistranded with copper conductor drawn through and including 20 mm dia non metallic rigid PVC white conduit and conduit/PVC casing caping accessories Concealed /fixed to walls / roofs / floors etc., and including provision of PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade 4.0 sqmm for earth continuity conductor and making good the disturbed surfaces also matching the exisiting surfaces all as specified and as directed by Engr-in-Charge. Note: Two runs of 4.00 sqmm single core PVC cable, PVC conduit/PVC casing caping and one run of 4.0sqmm PVC cable for earth continuity conductor shall be measured and paid as one RM .\n 1061 RM
18 18 Point wiring complete with1.5 sqmm single core PVC insulated heavy duty ISI Marked FR, unsheathed FRLS cable 1100 volts grade with multistranded copper conductor drawn through ERW conduit with all accessories fixed to the surface of walls/roof/ floors / ceiling etc., M S terminal boxes 60 mm deep concealed in walls covered with plastic laminated top cover sheet 3.0 mm thick fixed with cadmium plated iron screws etc incl 1.5 sqmm PVC insulated, unsheathed copper conductorMuistandere FRLS cable 1100V grade as earth continuity conductor & connecting to common earth dolly. for one light/Exhaust Fan point controlled by one switch. 3 Point
19 19 Supply and fix ceiling rose surface bakelite 65x50mm 3 terminals. 3 Each
20 20 Supply and fix Switch flame proof rotary Type with termination box in LM6, 16A, single pole 250V. 3 Each
21 21 S & F flame proof exhaust fan 305 mm (12)" sweep heavy duty 1440 RPM, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.5 sqmm (16/0.2 mm) from ceiling rose to fan including writing MES NO. 2 CM height with synthetic enamelled black paint all as specified and as directed \nMake:- Crompton/Havells/Usha/Sudhir or equivalent as approved by GE 1 Each
22 22 M & L for Provision of hole on the wall for fixing of the exhaust fan and connecting with the ceiling rose complete all as specified and directed by Engr-In-charge. 1 Each Job
23 23 Sub main wiring complete with two runs of 1.5 Sqmm single core PVC insulated heavy duty ISI Marked unsheathed cable 1100 volts grade, multistanded with copper conductor drawn through and including 20 mm dia non matallic rigid PVC conduit and conduit accessories concealed /fixed to walls/roofs/floors etc.., and including provision of PVC insulated heavy duty ISI Marked, unsheathed cable 1100 volts grade 1.5 Sqmm for earth continuity conductor and making good the disturbed surface also matching the existing surface all as specified and as directed by Engineer-in-charge.\nNote:- Two Run of 1.5 Sq mm, one Run of 1.5 Sqmm And PVC conduct is measured as one Run or one Meter. 210 RM
24 24 S&F Bell Push flush type. 2 Each
25 25 Supply and fix Bell Multi Music type AC 230 V complete. 2 Each
26 26 Supply and Fixing 36 watts 5700 K Recess Mounting LED fittings with Control driver with higher efficacy full diffuser providing uniform light and luminaire gives soft glare free light suitable for POP / GYPSUM ceiling and all as specified and directed by Engr-in-Charge. \nMake : Wipro Cat Part No. CRCO10R038HP57GL1 or equivalent make of Havells/Crompton/Bajaj. 15 Each
27 Total in Figures