Repairs Renewal Of Apfc Panel , Amf Panel , Acbs , Mccbs , Capacitor , Ammeter And Connected Items Under Age Em No Ii Of Ge Utility Secunderabad, SECUNDERABAD-Telangana

Military Engineer Services-MES has published Repairs Renewal Of Apfc Panel , Amf Panel , Acbs , Mccbs , Capacitor , Ammeter And Connected Items Under Age Em No Ii Of Ge Utility Secunderabad. Submission Date for this Tender is 29-08-2020. Electrical Panel Tenders in SECUNDERABAD Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

25111397
Repairs Renewal Of Apfc Panel , Amf Panel , Acbs , Mccbs , Capacitor , Ammeter And Connected Items Under Age Em No Ii Of Ge Utility Secunderabad
Open Tender
Indian
Telangana
SECUNDERABAD
29-08-2020

Tender Details

Repairs Renewal Of Apfc Panel , Amf Panel , Acbs , Mccbs , Capacitor , Ammeter And Connected Items Under Age Em No Ii Of Ge Utility Secunderabad

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: REPAIRS/RENEWAL OF APFC PANEL, AMF PANEL, ACBs, MCCBs, CAPACITOR, AMMETER AND CONNECTED ITEMS UNDER AGE E/M NO II OF GE UTILITY SECUNDERABAD.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for capacitor banks, ( control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 400 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 45cm below ground level and 15cm above ground level and comprising of the following\n BI01010001010000000000000515BI0100001112 2 Each Job
2 1.01 (a) MCCB, 4 pole, 500 Amps with ultimate breaking capacity Icu - 50kA at 415 Volts and microprocessor release conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 50kA, overload setting 70% to 100% - 01 Nos ( As Incomer)\n(b) MCCB, 3 pole, 125 Amps with ultimate breaking capacity Icu - 16kA at 415 Volts and thermal magnetic release conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 16kA- 02 Nos\n(c) MCB, 3 pole, 40-63 Amps with ultimate breaking capacity Icu - 10kA at 415 Volts conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 10kA-03Nos.\n(d) MCB, 3 pole, 6-32 Amps with ultimate breaking capacity Icu - 10kA at 415 Volts conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 10kA-03Nos.\n(e) Capacitor Banks, 50kVAR (1X50kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos\n(f) Capacitor Banks, 50kVAR (1X50kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos\n(g) Capacitor Banks, 25kVAR (1X25kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos\n(h) Capacitor Banks, 25kVAR (1X25kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos\n(i) Capacitor Banks, 20kVAR (1X20kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos\n(j) Capacitor Banks, 15kVAR (1X15kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos\n BI01010001010000000000000515BI0100001113
3 1.02 (k) Capacitor Banks, 10kVAR (1X10kVAR) each, 3 Phase 415v Heavy duty box type - 01 Nos\n(l) Capacitor Banks, 5kVAR (1X5kVAR) each, 3 Phase 415v Heavy duty box type- 01 Nos\n(m) Capacitor Duty Contactor for 50kVAR Capacitor bank 415V,50Hz - 02 Nos\n(n) Capacitor Duty Contactor for 25kVAR Capacitor bank 415V,50Hz - 02 Nos\n(o) Capacitor Duty Contactor for 20kVAR Capacitor bank 415V,50Hz - 01 Nos\n(p)Capacitor Duty Contactor for 15kVAR Capacitor bank 415V,50Hz - 01 Nos\n(q)Capacitor Duty Contactor for 10kVAR Capacitor bank 415V,50Hz - 01 Nos\n(r)Capacitor Duty Contactor for 5kVAR Capacitor bank 415V,50Hz - 01 Nos\n(p) APFC Relay 10 Steps, Microprocessor based release(08Step controller+02 plug-in-Module).\n(m) Auto / Manual selector switch for each capacitor bank.\n(n) Eliminatiry push button red/green for each capacitor bank.\n(n) 200Amps TPN Copper busbar eith colour coded heat shrinkable sleeve.\n(o) necessary control for APFC panel with suitable size of PVC insulated stranded copper conductor cable duiy crimped with copper lugs & ferruled and complete panel testing.\nd)Multi function meter VAF+PF,CI 0.5 -01No Make:L&T Cat no.WL411021OOOO or its techno commercial equivalent make in Scheider/SIEMENS/ABB.\n(e)Aluminium Busbar 800 Amps with Sleeves -04( three phase with neutral and connectors set of 4).\n(f) Suitable primary & secondary of selection CT coil in each phases with suitable VA burden along with CT shoot terminals .\n(g)Insulators: Epoxy insulators. BI01010001010000000000000515BI0100001114
4 2 Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 120 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in \n BI01010001010000000000000515BI0100001115 5 Each Job
5 2.01 industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level and comprising of the following:-(A)Incoming ,Outgoings & Other Misc items:-\n(a) MCCB 200 Amps Four Pole AC 415 Volts,50Hz,25kA-01Nos( free for fixing only).\n(b) MCB 16-63 Amps(Selection of rating shall be as directed by Engr-in-Charge),Three pole AC 415 volts,50Hz,10kA -04 Nos (free for fixing only)\n(c) Capacitor banks of capacity 5kVAR to 25 kVAR(Selection of rating shall be as directed by Engr-in-Charge) -04 Nos (free for fixing only)\n\n BI01010001010000000000000515BI0100001116
6 2.02 (d)Multi function meter VAF+PF,CI 0.5 -01No Make:L&T Cat no.WL411021OOOO or its techno commercial equivalent make in Scheider/SIEMENS/ABB.\n(e)Aluminium Busbar 300 Amps with Sleeves -04( three phase with neutral and connectors set of 4).\n(f) Suitable primary & secondary of selection CT coil in each phases with suitable VA burden along with CT shoot terminals .\n(g)Insulators: Epoxy insulators.\nNote: MCCBs,MCBs,Capacitor banks shall be measured and paid separately under relevant items. BI01010001010000000000000515BI0100001117
7 3 Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 95 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level including taking down old unserviceable at MH and comprising of the following:-\n BI01010001010000000000000515BI0100001118 6 Each Job
8 3.01 (A)Incoming ,Outgoings & Other Misc items:-\n(a) MCCB 160 Amps Four Pole AC 415 Volts,50Hz,25kA-01Nos (free for fixing only).\n(b) MCB 16-63 Amps(Selection of rating shall be as directed by Eng-in-Charge),Three pole AC 415 volts,50Hz,10kA -04 Nos (free for fixing only)\n(c) Capacitor banks of capacity 5kVAR to 25 kVAR (Selection of rating shall be as directed by Eng-in-Charge)-04 Nos (free for fixing only)\n(d)Multi function meter VAF+PF,CI 0.5 -01No Make:L&T Cat no.WL411021OOOO or its techno commercial equivalent make in Scheider/SIEMENS/ABB.\n(e)Aluminium Busbar 250 Amps with Sleeves -04( three phase with neutral and connectors set of 4).\n(f) Suitable primary & secondary of selection CT coil in each phases with suitable VA burden along with CT shoot terminals .\n(g)Insulators: Epoxy insulators.\nNote: MCCBs,MCBs,Capacitor banks shall be measured and paid separately under relevant items.\n BI01010001010000000000000515BI0100001119
9 4 Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 95 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm a and comprising of the following:-\n BI01010001010000000000000515BI0100001120 6 Each Job
10 4.01 (A)Incoming ,Outgoings & Other Misc items:-\n(a) MCCB 125 Amps Four Pole AC 415 Volts,50Hz,25kA-01Nos (free for fixing only).\n(b) MCB 16-63 Amps(Selection of rating shall be as directed by Eng-in-Charge),Three pole AC 415 volts,50Hz,10kA -04 Nos (free for fixing only).\n(c) Capacitor banks of capacity 5kVAR to 25 kVAR(Selection of rating shall be as directed by Eng-in-Charge) -04 Nos (free for fixing only).\n(d)Multi function meter VAF+PF,CI 0.5 -01No Make:L&T Cat no.WL411021OOOO or its techno commercial equivalent make in Scheider/SIEMENS/ABB.\n(e)Aluminium Busbar 200 Amps with Sleeves -04( three phase with neutral and connectors set of 4).\n(f) Suitable primary & secondary of selection CT coil in each phases with suitable VA burden along with CT shoot terminals .\n(g)Insulators: Epoxy insulators.\nNote: MCCBs,MCBs,Capacitor banks shall be measured and paid separately under relevant items.\n BI01010001010000000000000515BI0100001121
11 5 Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 95 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level including taking down old unserviceable at MH and comprising of the following:-\n BI01010001010000000000000515BI0100001122 15 Each Job
12 5.01 (A)Incoming ,Outgoings & Other Misc items:-\n(a) MCCB 100 Amps Four Pole AC 415 Volts,50Hz,25kA-01Nos free for fixing only.\n(b) MCB 16-63 Amps(Selection of rating shall be as directed by Eng-in-Charge),Three pole AC 415 volts,50Hz,10kA -04 Nos (free for fixing only).\n(c) Capacitor banks of capacity 5kVAR to 25 kVAR(Selection of rating shall be as directed by Eng-in-Charge) -04 Nos (free for fixing only).\nd)Multi function meter VAF+PF,CI 0.5 -01No Make:L&T Cat no.WL411021OOOO or its techno commercial equivalent make in Scheider/SIEMENS/ABB.\n(e)Aluminium Busbar 150 Amps with Sleeves -04( three phase with neutral and connectors set of 4).\n(f) Suitable primary & secondary of selection CT coil in each phases with suitable VA burden along with CT shoot terminals .\n(g)Insulators: Epoxy insulators.\nNote: MCCBs,MCBs,Capacitor banks shall be measured and paid separately under relevant items.\n BI01010001010000000000000515BI0100001123
13 6 Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size to accommodate the under mentioned items with proper working space , 3 Phase 4 wire system outdoor type 3.15mm thickness ,double door front and back openeing type sloped canopy(Hood) on top extended all-around, separate compartments for each capacitor bank(Total Number of capacitor banks shall be accommodated are 04Nos,capacity of each capacitor bank shall be varied from 5kVAR to 25kVAR), control gear, cable alley,busbar chamber,cable entry, provision of knock out type plates(gland plate) for various sizes of cable up to 95 Sqmm 3.5 Core in and out( panel board shall have sufficent space for working) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm out door thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level including taking down old unserviceable at MH and comprising of the following:-\n\n BI01010001010000000000000515BI0100001124 18 Each Job
14 6.01 (A)Incoming ,Outgoings & Other Misc items:-\n(a) MCCB 32-63 Amps Four Pole AC 415 Volts,50Hz,25kA-01Nos (free for fixing only).\n(b) MCB 16-63 Amps(Selection of rating shall be as directed by Eng-in-Charge),Three pole AC 415 volts,50Hz,10kA -04 Nos (free for fixing only).\n(c) Capacitor banks of capacity 5kVAR to 25 kVAR(Selection of rating shall be as directed by Eng-in-Charge) -04 Nos (free for fixing only).\n(d)Multi function meter VAF+PF,CI 0.5 -01No Make:L&T Cat no.WL411021OOOO or its techno commercial equivalent make in Scheider/SIEMENS/ABB.\n(e)Aluminium Busbar 150 Amps with Sleeves -04( three phase with neutral and connectors set of 4).\n(f) Suitable primary & secondary of selection CT coil in each phases with suitable VA burden along with CT shoot terminals .\n(g)Insulators: Epoxy insulators.\nNote: MCCBs,MCBs,Capacitor banks shall be measured and paid separately under relevant items.\n BI01010001010000000000000515BI0100001125
15 7 Supply only 4 pole MCCB 200 amps 25kA,50Hz,440v with adjustable settings in new panel including necessary wiring & misc accessroies for satisfactory completion of job one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001126 5 Each
16 8 Supply only 4 pole MCCB 160 amps 25kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001127 6 Each
17 9 Supply only 4 pole MCCB 125 amps 16kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001128 6 Each
18 10 Supply only 4 pole MCCB 100 amps 16kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001129 15 Each
19 11 Supply only of 4 pole MCCB 32-63 amps 16kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001130 18 Each
20 12 Supply only of 3 pole MCB 16-32 amps,C-curve,10kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001131 95 Each
21 13 Supply only of 3 pole MCB 40-63amps,C-curve,10kA,50Hz,440v in new panel including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001132 95 Each
22 14 Supply only heavy duty box type capacitors 5kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001133 40 Each\nJob
23 15 Supply only heavy duty box type capacitors 10kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001134 40 Each\nJob
24 16 Supply only heavy duty box type capacitors 15kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001135 39 Each\nJob
25 17 Supply only heavy duty box type capacitors 20kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001136 35 Each\nJob
26 18 Supply only heavy duty box type capacitors 25kVAR in new panel including including necessary wiring & misc accessroies for satisfactory completion of job complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001137 20 Each\nJob
27 19 Supply&Fixing elimator push button in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001138 18 Each
28 20 M& L for control wiring,relay programming and panel testing complete all as directed by Engr-in-Charge. BI01010001010000000000000515BI0100001139 15 Each\nJob
29 21 Supply&Fixing heavy duty box type capacitors 5kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001140 25 Each\nJob
30 22 Supply&Fixing heavy duty box type capacitors 10kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001141 20 Each\nJob
31 23 Supply&Fixing heavy duty box type capacitors 15kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001142 20 Each\nJob
32 24 Supply&Fixing heavy duty box type capacitors 20kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001143 20 Each\nJob
33 25 Supply&Fixing heavy duty box type capacitors 25kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001144 10 Each\nJob
34 26 Supply&Fixing heavy duty box type capacitors 50kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001145 3 Each\nJob
35 27 Supply&Fixing ultra heavy duty box type capacitors 20kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001146 3 Each\nJob
36 28 Supply&Fixing APFC relay 6 stage in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:HPL/L&T/Schnieder BI01010001010000000000000515BI0100001147 3 Each\nJob
37 29 Supply&Fixing APFC relay 8 stages in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:HPL/L&T/Schnieder BI01010001010000000000000515BI0100001148 10 Each\nJob
38 30 Supply&Fixing of capacitor duty contactor suitable for capacitor rating 5 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake: Schnieder/L&T/Seimens BI01010001010000000000000515BI0100001149 18 Each
39 31 Supply&Fixing of capacitor duty contactor suitable for capacitor rating 10 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake: Schnieder/L&T/Seimens BI01010001010000000000000515BI0100001150 15 Each
40 32 Supply&Fixing of capacitor duty contactor suitable for capacitor rating 15 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake: Schnieder/L&T/Seimens BI01010001010000000000000515BI0100001151 15 Each
41 33 Supply&Fixing of capacitor duty contactors suitable for capacitor rating 25 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake: Schnieder/L&T/Seimens BI01010001010000000000000515BI0100001152 10 Each
42 34 Supply&Fixing of 6 No Auxiliray conactor ,50Hz,240v in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001153 5 Each\nJob
43 35 Supply&Fixing of Auto/Manual selector swtich in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\nMake:L&T/Schnieder/Seimens BI01010001010000000000000515BI0100001154 15 Each\nJob
44 36 Supply&Fixing of 200/5 Amps Current transformer in each phase including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\n BI01010001010000000000000515BI0100001155 5 Each Job
45 37 Supply&Fixing of 400/5 Amps Current transformer in Each phase including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.\n BI01010001010000000000000515BI0100001156 5 Each Job
46 38 M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. \nNote :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade. BI01010001010000000000000515BI0100001157 27 Each Job
47 39 Shifting of existing APFC(Auto power factor correction) panel by disconnectioning of all electrical/mechanical connections & dismantling of exsiting PCC and install & commissioning in proposed location with suitable Panel mounted on suitable size angle iron frame thick duly painted and embeded in PCC 1:3:6 type C1, 30cm below ground level and 15cm complete all as directed by Engr-in-Charge. BI01010001010000000000000515BI0100001158 27 Each Job