Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #25096857

Thanjavur District - Package No . 39 - Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In S . Pudur And Sathanur Panchayats In Thiruvidaimarudur Block For The Year 2020-21 .

Issued by Local Bodies · Thiruvidaimarudur, Tamil Nadu
Tender Value
1.02 Crore
Estimated cost
Bid Submission
14 Aug 2020
0 days left
EMD
1.03 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvidaimarudur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Thanjavur District - Package No . 39 - Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In S . Pudur And Sathanur Panchayats In Thiruvidaimarudur Block For The Year 2020-21 .

BOQ

Name of Work: THANJAVUR DISTRICT - JAL JEEVAN MISSION - 2020-2021. Part.1. Providing Functional Household Tap Connections (FHTCs) and water supply works in S. Pudur Panchayat, Part.2. Providing Functional Household Tap Connections (FHTCs) and water supply works at Ariyankoonthalur and Mallarpettai habitations in Sathanur Panchayat. Part.3. Providing Functional Household Tap Connections (FHTCs) and water supply works at Sathanur habitation in Sathanur Panchayat
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Part .01. Providing Functional Household Tap Connections (FHTCs) and water supply works in S. Pudur Panchayat.
221. Vadumangudi Habitation
33Repairs to 30000 Litre OHT Vadumangudi
44Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.34.71Sq.m
55Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.71.85Sq.m
66Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
77Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate) using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement, centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
88Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.157.22Sq.m
99Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
1010Inner Ladder
1111RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
1212Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
1313Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
1414Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
1515Manhole
1616Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
1717centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
1818Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
1919Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate) using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
2020Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
2121Ventilation
2222Supply and delivery of 50mm Gi pipe0.6Rm
232350mm GI Elbow2Nos
242450mm GI Tee1Nos
2525Cutting of 50mm GI pipe5Nos
2626Threading of 50mm GI pipe5Nos
2727supply of weld mesh with welding and fixing charges1Nos
2828Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
2929Supply and delivery of 50mm GI Pipes.35.5Rm
3030Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
3131Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200133Rm
3232Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n33Nos.
3333HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)33Nos.
3434Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n33Nos.
3535Labour charges for Drilling,Cutting and fixing flow control valve in distribution line33Nos.
3636Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
3737Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20014Cu.m
3838Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n4Nos.
3939HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)4Nos.
4040Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n4Nos.
4141Labour charges for Drilling,Cutting and fixing flow control valve in distribution line4Nos.
4242NEW FHTC - 63 x 20mm
4343HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)98Nos.
4444Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n98Nos.
4545Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n98Nos.
4646Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm294Nos.
4747MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm784Rm
4848Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)588Rm
4949Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber784Rm
5050Supply & Jointing 20 mm Waste Not tap98Metre.
5151Labour charges for Drilling,Cutting and fixing flow control valve in distribution line98Nos.
5252Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc98Nos.
5353Cutting MDPE Pipes and specials true axis and finishing the end complete392Nos.
5454NEW FHTC - 75 x 20mm
5555HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)11Nos.
5656Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n11Nos.
5757Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n11Nos.
5858Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm33Nos.
5959MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm88Rm
6060Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)66Rm
6161Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber88Rm
6262Supply & Jointing 20 mm Waste Not tap11Nos.
6363Labour charges for Drilling,Cutting and fixing flow control valve in distribution line11Nos.
6464Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc11Nos.
6565Cutting MDPE Pipes and specials true axis and finishing the end complete44Nos.
6666Distribution Line 63mm PVC Pipe
6767Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001805R.M
6868Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
696963 mm OD PVC Pipe 4 KSC805R.M
7070Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
717163 mm OD PVC Pipe 4 KSC805R.M
7272Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
737363 mm OD PVC Pipe 4 KSC805R.M
7474Solvent Cement @ 0.75 Lit/100 m.6.038Lit.
7575Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
767663mm PVC Bend7Nos
777763mm x 50mm PVC Threaded coupler9Nos
787863mm x 50mm PVC Tee12Nos
797963mm End cap8Nos
8080Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
8181a.50mm GI pipe for culvert7Rm
8282b.50mm GI pipe for road portion28Rm
8383c.50mm GI Tee2Rm
8484Supply and delivery of GI specials to site of work as per IS specification with ISI marking
8585a.50mm GI Elbow page 25 sl.no 14Nos
8686b 50mm GI coupling page 25, sl.no 312Nos
8787Laying and jointing of GI Pipes with GI specials and PVC specials etc
8888a.50 mm dia Pipe7Rm
8989Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1Nos
9090Water meter Dirt BOX1No
9191Water meter erection charges1No
9292Provision for pit for Dual line1No
9393Distribution Line 75mm PVC Pipe
9494Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200190R.M
9595Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
969675 mm OD PVC Pipe 4 KSC90R.M
9797Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
989875 mm OD PVC Pipe 4 KSC90R.M
9999Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
10010075 mm OD PVC Pipe 4 KSC90Rm
101101Solvent Cement @ 0.75 Lit/100 m.0.675Lit.
102102Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
10310375mm PVC Bend2Nos
10410475mm PVC coupler3Nos
10510575mm PVC Tee3Nos
10610675mm End cap4Nos
107107Construction of Road for Restoring the Cut Portion.
108108Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.1.44Cu.m
109109Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.0.96Cu.m
110110Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.0.96Cu.m
111111Provision for Name Board1Nos
1121122. Sangarankudi Habitation
113113Repairs to 30000 Litre OHT Sangarankudi
114114Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.57.39Sq.m
115115Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.78.1Sq.m
116116Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
117117Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but including cost of mixing of concrete, placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
118118Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.150.48Sq.m
119119Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
120120Inner Ladder
121121RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
122122Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
123123Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
124124Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
125125Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
126126Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
127127Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200173Rm
128128Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n73Nos.
129129HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)73Nos.
130130Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n73Nos.
131131Labour charges for Drilling,Cutting and fixing flow control valve in distribution line73Nos.
132132Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
133133Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20018Cu.m
134134Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n8Nos.
135135HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)8Nos.
136136Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n8Nos.
137137Labour charges for Drilling,Cutting and fixing flow control valve in distribution line8Nos.
138138NEW FHTC - 63 x 20mm
139139HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)64Nos.
140140Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n64Nos.
141141Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n64Nos.
142142Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm192Nos.
143143MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm512Rm
144144Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)384Rm
145145Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber512Rm
146146Supply & Jointing 20 mm Waste Not tap64Nos.
147147Labour charges for Drilling,Cutting and fixing flow control valve in distribution line64Nos.
148148Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc64Nos.
149149Cutting MDPE Pipes and specials true axis and finishing the end complete256Nos.
150150NEW FHTC - 75 x 20mm
151151HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)8Nos.
152152Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n8Nos.
153153Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n8Nos.
154154Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm24Nos.
155155MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm64Rm
156156Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)48Rm
157157Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber64Rm
158158Supply & Jointing 20 mm Waste Not tap8Nos.
159159Labour charges for Drilling,Cutting and fixing flow control valve in distribution line8Nos.
160160Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc8Nos.
161161Cutting MDPE Pipes and specials true axis and finishing the end complete32Nos.
162162Distribution Line 63mm PVC Pipe
163163Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20011057R.M
164164Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
16516563 mm OD PVC Pipe 4 KSC1057R.M
166166Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
16716763 mm OD PVC Pipe 4 KSC1057R.M
168168Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
16916963 mm OD PVC Pipe 4 KSC1057R.M
170170Solvent Cement @ 0.75 Lit/100 m.7.928Lit.
171171Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
17217263mm PVC Bend10Nos
17317363mm x 50mm PVC Threaded coupler8Nos
17417463mm x 50mm PVC Tee11Nos
17517563mm End cap6Nos
176176Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
177177a.50mm GI pipe for culvert21Rm
178178b.50mm GI pipe for road portion56Rm
179179c.50mm GI Tee4Rm
180180Supply and delivery of GI specials to site of work as per IS specification with ISI marking
181181a.50mm GI Elbow page 25 sl.no 12Nos
182182b 50mm GI coupling page 25, sl.no 324Nos
183183Laying and jointing of GI Pipes with GI specials and PVC specials etc
184184a.50 mm dia Pipe21Rm
185185Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1Nos
186186Water meter Dirt BOX1Nos
187187Water meter erection charges1Nos
188188Provision for pit for Dual line1Nos
189189Distribution Line 75mm PVC Pipe
190190Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001117R.M
191191Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
19219275 mm OD PVC Pipe 4 KSC117R.M
193193Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
19419475 mm OD PVC Pipe 4 KSC117R.M
195195Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
19619675 mm OD PVC Pipe 4 KSC117Rm
197197Solvent Cement @ 0.75 Lit/100 m.0.888Lit.
198198Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
19919975mm PVC Bend2Nos
20020075mm PVC coupler3Nos
20120175mm PVC Tee3Nos
20220275mm End cap4Nos
203203Construction of Road for Restoring the Cut Portion.
204204Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.2.88Cu.m
205205Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.1.92Cu.m
206206Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.1.92Cu.m
207207Provision for Name Board1No
2082083. Keelasethi Habitation
209209Repairs to 30000 Litre OHT Keelasethi
210210Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.57.39Sq.m
211211Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.71.85Sq.m
212212Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
213213Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
214214Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.157.24Sq.m
215215Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
216216Inner Ladder
217217RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
218218Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
219219Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
220220Labour charges for lowering and fixing of RCC ladder inside the OHT1No
221221Manhole
222222Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
223223centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.m
224224Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
225225Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
226226Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1No
227227Ventilation
228228Supply and delivery of 50mm Gi pipe0.6Rm
22922950mm GI Elbow2Nos
23023050mm GI Tee1No
231231Cutting of 50mm GI pipe5Nos
232232Threading of 50mm GI pipe5Nos
233233supply of weld mesh with welding and fixing charges1No
23423465mm Gate Valve2Nos
235235Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
236236Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
237237Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200138Rm
238238Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n38Nos.
239239HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)38Nos.
240240Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n38Nos.
241241Labour charges for Drilling,Cutting and fixing flow control valve in distribution line38Nos.
242242Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
243243Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20014Cu.m
244244Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n4Nos.
245245HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)4Nos.
246246Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n4Nos.
247247Labour charges for Drilling,Cutting and fixing flow control valve in distribution line4Nos.
248248NEW FHTC - 63 x 20mm
249249HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)31Nos.
250250Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n31Nos.
251251Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n31Nos.
252252Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm93Nos.
253253MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm248Rm
254254Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)186Rm
255255Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber248Rm
256256Supply & Jointing 20 mm Waste Not tap31Nos.
257257Labour charges for Drilling,Cutting and fixing flow control valve in distribution line31Nos.
258258Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc31Nos.
259259Cutting MDPE Pipes and specials true axis and finishing the end complete124Nos.
260260NEW FHTC - 75 x 20mm
261261HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)3Nos.
262262Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n3Nos.
263263Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n3Nos.
264264Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm9Nos.
265265MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm24Rm
266266Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)18Rm
267267Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber24Rm
268268Supply & Jointing 20 mm Waste Not tap3Nos.
269269Labour charges for Drilling,Cutting and fixing flow control valve in distribution line3Nos.
270270Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc3Nos.
271271Cutting MDPE Pipes and specials true axis and finishing the end complete12Nos.
272272Distribution Line 63mm PVC Pipe
273273Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001684R.M
274274Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
27527563 mm OD PVC Pipe 4 KSC684R.M
276276Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
27727763 mm OD PVC Pipe 4 KSC684R.M
278278Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
27927963 mm OD PVC Pipe 4 KSC684R.M
280280Solvent Cement @ 0.75 Lit/100 m.5.13Lit.
281281Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
28228263mm PVC Bend9Nos
28328363mm x 50mm PVC Threaded coupler4Nos
28428463mm x 50mm PVC Tee9Nos
28528563mm End cap5Nos
286286Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
287287a.50mm GI pipe for culvert7Rm
288288b.50mm GI pipe for road portion42Rm
289289c.50mm GI Tee2Rm
290290Supply and delivery of GI specials to site of work as per IS specification with ISI marking
291291a.50mm GI Elbow page 25 sl.no 12Nos
292292b 50mm GI coupling page 25, sl.no 318Nos
293293Laying and jointing of GI Pipes with GI specials and PVC specials etc
294294a.50 mm dia Pipe7Rm
295295Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1No
296296Water meter Dirt BOX1No
297297Water meter erection charges1No
298298Provision for pit for Dual line1No
299299Distribution Line 75mm PVC Pipe
300300Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200176R.M
301301Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
30230275 mm OD PVC Pipe 4 KSC76R.M
303303Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
30430475 mm OD PVC Pipe 4 KSC76R.M
305305Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
30630675 mm OD PVC Pipe 4 KSC76Rm
307307Solvent Cement @ 0.75 Lit/100 m.0.57Lit.
308308Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
30930975mm PVC Bend2Nos
31031075mm PVC coupler3Nos
31131175mm PVC Tee3Nos
31231275mm End cap4Nos
313313Construction of Road for Restoring the Cut Portion.
314314Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.2.16Cu.m
315315Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.1.44Cu.m
316316Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.1.44Cu.m
317317Provision for Name Board1No
3183184. S.Puthur Habitation
319319Repairs to 10000 Litre OHT at Mela veethi
320320Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.29.6Sq.m
321321Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.65.39Sq.m
322322Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
323323Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate) using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but including cost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
324324Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.124.24Sq.m
325325Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
326326Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
327327Supply and delivery of 50mm GI Pipes.3Rm
328328Repairs to 30000 Litre OHT at Vadakku Madha Kovil
329329Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.57.39Sq.m
330330Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.71.85Sq.m
331331Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
332332Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement, centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
333333Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.157.29Sq.m
334334Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
335335Inner Ladder
336336RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
337337Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
338338Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
339339Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
340340Manhole
341341Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
342342Centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
343343Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
344344Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate) using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
345345Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
346346Ventilation
347347Supply and delivery of 50mm Gi pipe0.6Rm
34834850mm GI Elbow2Nos
34934950mm GI Tee1No
350350Cutting of 50mm GI pipe5Nos
351351Threading of 50mm GI pipe5Nos
352352supply of weld mesh with welding and fixing charges1No
353353Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
35435465mm GI coupling2Rm
355355Repairs to 100000 Litre OHT at S.Pudur
356356Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.50.19Sq.m
357357Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.24.23Sq.m
358358Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement, centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.1.12Cu.m
359359Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.385.79Sq.m
360360Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
36136180mm Gate valve2Ls
362362Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.26.38Sq.m
36336365mm GI coupling1Rm
364364Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
365365Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001230Rm
366366Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n230Nos.
367367HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)230Nos.
368368Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n230Nos.
369369Labour charges for Drilling,Cutting and fixing flow control valve in distribution line230Nos.
370370Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
371371Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200126Cu.m
372372Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n26Nos.
373373HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)26Nos.
374374Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n26Nos.
375375Labour charges for Drilling,Cutting and fixing flow control valve in distribution line26Nos.
376376NEW FHTC - 63 x 20mm
377377HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)416Nos.
378378Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n416Nos.
379379Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n416Nos.
380380Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm1248Nos.
381381MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm3328Rm
382382Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)2496Rm
383383Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber3328Rm
384384Supply & Jointing 20 mm Waste Not tap416Metre.
385385Labour charges for Drilling,Cutting and fixing flow control valve in distribution line416Nos.
386386Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc416Nos.
387387Cutting MDPE Pipes and specials true axis and finishing the end complete1664Nos.
388388NEW FHTC - 75 x 20mm
389389HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)56Nos.
390390Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n56Nos.
391391Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n56Nos.
392392Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm168Nos.
393393MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm448Rm
394394Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)336Rm
395395Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber448Rm
396396Supply & Jointing 20 mm Waste Not tap56Nos.
397397Labour charges for Drilling,Cutting and fixing flow control valve in distribution line56Nos.
398398Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc56Nos.
399399Cutting MDPE Pipes and specials true axis and finishing the end complete224Nos.
400400Distribution Line 63mm PVC Pipe
401401Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20012655R.M
402402Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
40340363 mm OD PVC Pipe 4 KSC2655R.M
404404Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
40540563 mm OD PVC Pipe 4 KSC2655R.M
406406Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
40740763 mm OD PVC Pipe 4 KSC2655R.M
408408Solvent Cement @ 0.75 Lit/100 m.19.913Lit.
409409Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
41041063mm PVC Bend21Nos
41141163mm x 50mm PVC Threaded coupler11Nos
41241263mm x 50mm PVC Tee15Nos
41341363mm End cap8Nos
414414Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
415415a.50mm GI pipe for culvert42Rm
416416b.50mm GI pipe for road portion84Rm
417417c.50mm GI Tee2Rm
418418Supply and delivery of GI specials to site of work as per IS specification with ISI marking
419419a.50mm GI Elbow page 25 sl.no 14Nos
420420b 50mm GI coupling page 25, sl.no 336Nos
421421Laying and jointing of GI Pipes with GI specials and PVC specials etc
422422a.50 mm dia Pipe42Rm
423423Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1Nos
424424Water meter Dirt BOX1Nos
425425Water meter erection charges1Nos
426426Provision for pit for Dual line1Nos
427427Distribution Line 75mm PVC Pipe
428428Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001295R.M
429429Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
43043075 mm OD PVC Pipe 4 KSC295R.M
431431Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
43243275 mm OD PVC Pipe 4 KSC295R.M
433433Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
43443475 mm OD PVC Pipe 4 KSC295Rm
435435Solvent Cement @ 0.75 Lit/100 m.2.213Lit.
436436Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
43743775mm PVC Bend2Nos
43843875mm PVC coupler3Nos
43943975mm PVC Tee3Nos
44044075mm End cap4Nos
441441Construction of Road for Restoring the Cut Portion.
442442Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.4.32Cu.m
443443Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.2.88Cu.m
444444Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.2.88Cu.m
445445Provision for Name Board1Nos
4464465. Ivelikandam Habitation
447447Repairs to 10000 Litre OHT Ivelikandam
448448Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.29.6Sq.m
449449Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.65.39Sq.m
450450Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
451451Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
452452Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.124.24Sq.m
453453Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
454454Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
455455Supply and delivery of 50mm GI Pipes.2Rm
456456Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
457457Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200110Rm
458458Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n10Nos.
459459HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)10Nos.
460460Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n10Nos.
461461Labour charges for Drilling,Cutting and fixing flow control valve in distribution line10Nos.
462462Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
463463Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20011Cu.m
464464Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n1Nos.
465465HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)1Nos.
466466Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n1Nos.
467467Labour charges for Drilling,Cutting and fixing flow control valve in distribution line1Nos.
468468NEW FHTC - 63 x 20mm
469469HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)2Nos.
470470Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n2Nos.
471471Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n2Nos.
472472Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm6Nos.
473473MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm16Rm
474474Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)12Rm
475475Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber16Rm
476476Supply & Jointing 20 mm Waste Not tap2Metre.
477477Labour charges for Drilling,Cutting and fixing flow control valve in distribution line2Nos.
478478Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc2Nos.
479479Cutting MDPE Pipes and specials true axis and finishing the end complete8Nos.
480480Distribution Line 63mm PVC Pipe
481481Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001195R.M
482482Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
48348363 mm OD PVC Pipe 4 KSC195R.M
484484Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
48548563 mm OD PVC Pipe 4 KSC195R.M
486486Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
48748763 mm OD PVC Pipe 4 KSC195R.M
488488Solvent Cement @ 0.75 Lit/100 m.1.463Lit.
489489Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
49049063mm PVC Bend5Nos
49149163mm x 50mm PVC Threaded coupler2Nos
49249263mm x 50mm PVC Tee4Nos
49349363mm End cap2Nos
494494Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
495495a.50mm GI pipe for culvert7Rm
496496b.50mm GI pipe for road portion7Rm
497497c.50mm GI Tee2Rm
498498Supply and delivery of GI specials to site of work as per IS specification with ISI marking
499499a.50mm GI Elbow page 25 sl.no 12Nos
500500b 50mm GI coupling page 25, sl.no 33Nos
501501Laying and jointing of GI Pipes with GI specials and PVC specials etc
502502a.50 mm dia Pipe7Rm
503503Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1Nos
504504Water meter Dirt BOX1Nos
505505Water meter erection charges1Nos
506506Provision for pit for Dual line1Nos
507507Distribution Line 75mm PVC Pipe
508508Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200121R.M
509509Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
51051075 mm OD PVC Pipe 4 KSC21R.M
511511Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
51251275 mm OD PVC Pipe 4 KSC21R.M
513513Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
51451475 mm OD PVC Pipe 4 KSC21Rm
515515Solvent Cement @ 0.75 Lit/100 m.0.158Lit.
516516Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
51751775mm PVC Bend2Nos
51851875mm PVC coupler3Nos
51951975mm PVC Tee3Nos
52052075mm End cap4Nos
521521Construction of Road for Restoring the Cut Portion.
522522Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.0.36Cu.m
523523Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.0.24Cu.m
524524Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.0.24Cu.m
525525To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977
526526To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD)1set
527527Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 1011set
528528Provision for Name Board1Nos
529529Part.2. Providing Functional Household Tap Connections (FHTCs) and water supply works at Ariyankoonthalur and Mallarpettai habitations in Sathanur Panchayat.
5305301. Mallarpettai Habitation
531531Repairs to 60000 Litre OHT Mallarpettai
532532Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.25.6Sq.m
533533Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.24.6Sq.m
534534Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
535535Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
536536Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.138.65Sq.m
537537Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
538538Inner Ladder
539539RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
540540Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
541541Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
542542Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
543543Manhole
544544Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
545545centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
546546Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
547547Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
548548Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
549549Ventilation
550550Supply and delivery of 50mm Gi pipe0.6Rm
55155150mm GI Elbow2Nos
55255250mm GI Tee1Nos
553553Cutting of 50mm GI pipe5Nos
554554Threading of 50mm GI pipe5Nos
555555supply of weld mesh with welding and fixing charges1Nos
55655680mm Gate Valve2Nos
55755780mm coupling4Nos
558558Air compresor2Hr
559559100mm flangeset2Hr
560560Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.20.41Sq.m
561561Supply and delivery of 65mm GI Pipes.6Rm
562562Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
563563Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200161Rm
564564Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n61Nos.
565565HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)61Nos.
566566Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n61Nos.
567567Labour charges for Drilling,Cutting and fixing flow control valve in distribution line61Nos.
568568Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
569569Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20017Cu.m
570570Common Items for HSC Connection - Flow Control Valve 20mm (3/4\")\n7Nos.
571571HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)7Nos.
572572Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n7Nos.
573573Labour charges for Drilling,Cutting and fixing flow control valve in distribution line7Nos.
574574NEW FHTC - 63 x 20mm
575575HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)41Nos.
576576Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n41Nos.
577577Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n41Nos.
578578Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm123Nos.
579579MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm328Rm
580580Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)246Rm
581581Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber328Rm
582582Supply & Jointing 20 mm Waste Not tap41Metre.
583583Labour charges for Drilling,Cutting and fixing flow control valve in distribution line41Nos.
584584Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc41Nos.
585585Cutting MDPE Pipes and specials true axis and finishing the end complete164Nos.
586586NEW FHTC - 75 x 20mm
587587HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)5Nos.
588588Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n5Nos.
589589Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n5Nos.
590590Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm15Nos.
591591MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm40Rm
592592Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)30Rm
593593Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber40Rm
594594Supply & Jointing 20 mm Waste Not tap5Nos.
595595Labour charges for Drilling,Cutting and fixing flow control valve in distribution line5Nos.
596596Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc5Nos.
597597Cutting MDPE Pipes and specials true axis and finishing the end complete20Nos.
598598Distribution Line 63mm PVC Pipe
599599Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20011791R.M
600600Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
60160163 mm OD PVC Pipe 4 KSC1791R.M
602602Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
60360363 mm OD PVC Pipe 4 KSC1791R.M
604604Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
60560563 mm OD PVC Pipe 4 KSC1791R.M
606606Solvent Cement @ 0.75 Lit/100 m.13.433Lit.
607607Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
60860863mm PVC Bend8Nos
60960963mm x 50mm PVC Threaded coupler4Nos
61061063mm x 50mm PVC Tee6Nos
61161163mm End cap4Nos
612612Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
613613a.50mm GI pipe for culvert14Rm
614614b.50mm GI pipe for road portion56Rm
615615c.50mm GI Tee2Rm
616616Supply and delivery of GI specials to site of work as per IS specification with ISI marking
617617a.50mm GI Elbow page 25 sl.no 14Nos
618618b 50mm GI coupling page 25, sl.no 324Nos
619619Laying and jointing of GI Pipes with GI specials and PVC specials etc
620620a.50 mm dia Pipe14Rm
621621Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1Nos
622622Water meter Dirt BOX1Nos
623623Water meter erection charges1Nos
624624Provision for pit for Dual line1Nos
625625Distribution Line 75mm PVC Pipe
626626Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001199R.M
627627Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
62862875 mm OD PVC Pipe 4 KSC199R.M
629629Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
63063075 mm OD PVC Pipe 4 KSC199R.M
631631Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
63263275 mm OD PVC Pipe 4 KSC199Rm
633633Solvent Cement @ 0.75 Lit/100 m.1.493Lit.
634634Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
63563575mm PVC Bend3Nos
63663675mm PVC coupler2Nos
63763775mm PVC Tee2Nos
63863875mm End cap3Nos
639639Construction of Road for Restoring the Cut Portion.
640640Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.2.88Cu.m
641641Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.1.92Cu.m
642642Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.1.92Cu.m
643643Provision for Name Board1No
6446442. Ariyankoonthalur Habitation
645645Repairs to 30000 Litre OHT Ariyankoonthalur
646646Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.14.53Sq.m
647647Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.28.99Sq.m
648648Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
649649Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
650650Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.156.71Sq.m
651651Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
652652Inner Ladder
653653RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
654654Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
655655Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
656656Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
657657Manhole
658658Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
659659centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
660660Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
661661Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
662662Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
663663Ventilation
664664Supply and delivery of 50mm Gi pipe0.6Rm
66566550mm GI Elbow2Nos
66666650mm GI Tee1Nos
667667Cutting of 50mm GI pipe5Nos
668668Threading of 50mm GI pipe5Nos
669669supply of weld mesh with welding and fixing charges1Nos
67067050mm Gate Valve1Nos
671671Air compresor2Hr
672672Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
673673Supply and delivery of 65mm GI coupling2Nos
674674100mm flange set2Nos
675675GI pipe 65mm9Nos
676676Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
677677Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200130Rm
678678Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n30Nos.
679679HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)30Nos.
680680Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n30Nos.
681681Labour charges for Drilling,Cutting and fixing flow control valve in distribution line30Nos.
682682Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
683683Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20013Cu.m
684684Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n3Nos.
685685HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)3Nos.
686686Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n3Nos.
687687Labour charges for Drilling,Cutting and fixing flow control valve in distribution line3Nos.
688688NEW FHTC - 63 x 20mm
689689HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)39Nos.
690690Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n39Nos.
691691Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n39Nos.
692692Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm117Nos.
693693MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm312Rm
694694Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)234Rm
695695Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber312Rm
696696Supply & Jointing 20 mm Waste Not tap39Metre.
697697Labour charges for Drilling,Cutting and fixing flow control valve in distribution line39Nos.
698698Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc39Nos.
699699Cutting MDPE Pipes and specials true axis and finishing the end complete156Nos.
700700NEW FHTC - 75 x 20mm
701701HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)4Nos.
702702Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n4Nos.
703703Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n4Nos.
704704Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm12Nos.
705705MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm32Rm
706706Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)24Rm
707707Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber32Rm
708708Supply & Jointing 20 mm Waste Not tap4Nos.
709709Labour charges for Drilling,Cutting and fixing flow control valve in distribution line4Nos.
710710Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc4Nos.
711711Cutting MDPE Pipes and specials true axis and finishing the end complete16Nos.
712712Distribution Line 63mm PVC Pipe
713713Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001533R.M
714714Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
71571563 mm OD PVC Pipe 4 KSC533R.M
716716Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
71771763 mm OD PVC Pipe 4 KSC533R.M
718718Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
71971963 mm OD PVC Pipe 4 KSC533R.M
720720Solvent Cement @ 0.75 Lit/100 m.3.998Lit.
721721Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
72272263mm PVC Bend5Nos
72372363mm x 50mm PVC Threaded coupler3Nos
72472463mm x 50mm PVC Tee4Nos
72572563mm End cap2Nos
726726Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
727727a.50mm GI pipe for culvert7Rm
728728b.50mm GI pipe for road portion21Rm
729729c.50mm GI Tee2Rm
730730Supply and delivery of GI specials to site of work as per IS specification with ISI marking
731731a.50mm GI Elbow page 25 sl.no 12Nos
732732b 50mm GI coupling page 25, sl.no 39Nos
733733Laying and jointing of GI Pipes with GI specials and PVC specials etc
734734a.50 mm dia Pipe7Rm
735735Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1Nos
736736Water meter Dirt BOX1Nos
737737Water meter erection charges1Nos
738738Provision for pit for Dual line1Nos
739739Distribution Line 75mm PVC Pipe
740740Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200159R.M
741741Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
74274275 mm OD PVC Pipe 4 KSC59R.M
743743Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
74474475 mm OD PVC Pipe 4 KSC59R.M
745745Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
74674675 mm OD PVC Pipe 4 KSC59Rm
747747Solvent Cement @ 0.75 Lit/100 m.0.443Lit.
748748Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
74974975mm PVC Bend2Nos
75075075mm PVC coupler2Nos
75175175mm PVC Tee1Nos
75275275mm End cap2Nos
753753Construction of Road for Restoring the Cut Portion.
754754Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.1.08Cu.m
755755Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.0.72Cu.m
756756Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.0.72Cu.m
757757To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977
758758To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 lpm77 (HEAD)1set
759759Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 1011set
760760Provision for Name Board1Nos
761761Part.3. Providing Functional Household Tap Connections (FHTCs) and water supply works at Sathanur habitation in Sathanur Panchayat.
762762Repairs to 10000 Litre OHT Sathanur Pattam
763763Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.14.53Sq.m
764764Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.28.99Sq.m
765765Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
766766Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
767767Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.156.72Sq.m
768768Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
769769Inner Ladder
770770RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
771771Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
772772Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
773773Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
774774Manhole
775775Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
776776Centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
777777Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
778778Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
779779Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
780780Ventilation
781781Supply and delivery of 50mm Gi pipe0.6Rm
78278250mm GI Elbow2Nos
78378350mm GI Tee1Nos
784784Cutting of 50mm GI pipe5Nos
785785Threading of 50mm GI pipe5Nos
786786supply of weld mesh with welding and fixing charges1Nos
78778750mm Gate Valve1Nos
788788Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
789789Supply and delivery of 50mm GI coupling2Nos
79079050mm flange set3Nos
791791GI pipe 50mm2Nos
792792Repairs to 60000 Litre OHT Sathanur PUES Near
793793Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.24.6Sq.m
794794Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
795795Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
796796Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.140.72Sq.m
797797Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
798798Inner Ladder
799799RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
800800Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
801801Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
802802Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
803803Manhole
804804Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
805805centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
806806Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
807807Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
808808Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
809809Ventilation
810810Supply and delivery of 50mm Gi pipe0.6Rm
81181150mm GI Elbow2Nos
81281250mm GI Tee1Nos
813813Cutting of 50mm GI pipe5Nos
814814Threading of 50mm GI pipe5Nos
815815supply of weld mesh with welding and fixing charges1Nos
81681680mm Gate Valve2Nos
817817Air compresor2Nos
818818Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.20.41Sq.m
819819Supply and delivery of 80mm GI coupling4Nos
820820100mm flange set4Nos
821821GI pipe 65mm6Nos
822822Repairs to 60000 Litre OHT Sathanur thelungu theru
823823Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.24.6Sq.m
824824Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
825825Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
826826Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.140.72Sq.m
827827Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
828828Inner Ladder
829829RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
830830Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
831831Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
832832Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
833833Manhole
834834Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
835835centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
836836Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
837837Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
838838Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
839839Ventilation
840840Supply and delivery of 50mm Gi pipe0.6Rm
84184150mm GI Elbow2Nos
84284250mm GI Tee1Nos
843843Cutting of 50mm GI pipe5Nos
844844Threading of 50mm GI pipe5Nos
845845supply of weld mesh with welding and fixing charges1Nos
84684665mm Gate Valve2Nos
847847Air compresor2Nos
848848Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.20.41Sq.m
849849Supply and delivery of 65mm GI coupling3Nos
850850100mm flange set4Nos
851851GI pipe 65mm10Nos
852852Repairs to 100000 Litre OHT Sathanur mela theru
853853Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.37.39Sq.m
854854Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.50.19Sq.m
855855Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.24.23Sq.m
856856Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.1.12Cu.m
857857Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.383.07Sq.m
858858Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
859859Inner Ladder
860860RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
861861Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
862862Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
863863Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
864864Manhole
865865Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
866866centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
867867Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
868868Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
869869Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
870870Ventilation
871871Supply and delivery of 50mm Gi pipe0.6Rm
87287250mm GI Elbow2Nos
87387350mm GI Tee1Nos
874874Cutting of 50mm GI pipe5Nos
875875Threading of 50mm GI pipe5Nos
876876supply of weld mesh with welding and fixing charges1Nos
87787765mm Gate Valve1Nos
878878Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.26.38Sq.m
879879Supply and delivery of 65mm GI coupling2Nos
880880100mm flange set2Nos
881881GI pipe 80mm4Nos
882882Repairs to 60000 Litre OHT Sathanur manthoppu theru
883883Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.14.53Sq.m
884884Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.28.99Sq.m
885885Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
886886Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
887887Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.156.71Sq.m
888888Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
889889Inner Ladder
890890RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
891891Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
892892Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
893893Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
894894Manhole
895895Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
896896centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
897897Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
898898Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
899899Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
900900Ventilation
901901Supply and delivery of 50mm Gi pipe0.6Rm
90290250mm GI Elbow2Nos
90390350mm GI Tee1Nos
904904Cutting of 50mm GI pipe5Nos
905905Threading of 50mm GI pipe5Nos
906906supply of weld mesh with welding and fixing charges1Nos
90790750mm Gate Valve2Nos
908908Air compresor2Nos
909909Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
910910Supply and delivery of 50mm GI coupling2Nos
91191150mm flange set2Nos
912912GI pipe 50mm12Nos
913913Repairs to 30000 Litre OHT Sathanur madhakoil theru
914914Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.24.6Sq.m
915915Supply and erection of sTeel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
916916Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate) using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of sTeel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
917917Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.140.72Sq.m
918918Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
919919Inner Ladder
920920RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
921921Supply, fabrication, placing in position of sTeel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
922922Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
923923Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
924924Manhole
925925Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
926926centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
927927Supply and Fabrication placing posistion of STeel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
928928Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
929929Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
930930Ventilation
931931Supply and delivery of 50mm Gi pipe0.6Rm
93293250mm GI Elbow2Nos
93393350mm GI Tee1Nos
934934Cutting of 50mm GI pipe5Nos
935935Threading of 50mm GI pipe5Nos
936936supply of weld mesh with welding and fixing charges1Nos
93793780mm Gate Valve2Nos
938938Air compresor2Nos
939939Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.20.41Sq.m
940940Supply and delivery of 80mm GI coupling2Nos
941941100mm flange set2Nos
942942GI pipe 65mm6Nos
943943Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
944944Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001430Rm
945945Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n430Nos.
946946HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)430Nos.
947947Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n430Nos.
948948Labour charges for Drilling,Cutting and fixing flow control valve in distribution line430Nos.
949949Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
950950Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200148Cu.m
951951Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n48Nos.
952952HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)48Nos.
953953Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n48Nos.
954954Labour charges for Drilling,Cutting and fixing flow control valve in distribution line48Nos.
955955NEW FHTC - 63 x 20mm
956956HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)453Nos.
957957Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n453Nos.
958958Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n453Nos.
959959Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm1359Nos.
960960MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm3624Rm
961961Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)2718Rm
962962Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber3624Rm
963963Supply & Jointing 20 mm Waste Not tap453Metre.
964964Labour charges for Drilling,Cutting and fixing flow control valve in distribution line453Nos.
965965Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc453Nos.
966966Cutting MDPE Pipes and specials true axis and finishing the end complete1812Nos.
967967NEW FHTC - 75 x 20mm
968968HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)50Nos.
969969Supply and delivery of Stainless sTeel Flow Control Valve having Stainless sTeel 202 grade body and Stainless sTeel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n50Nos.
970970Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n50Nos.
971971Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm150Nos.
972972MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm400Rm
973973Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)300Rm
974974Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber400Rm
975975Supply & Jointing 20 mm Waste Not tap50Nos.
976976Labour charges for Drilling,Cutting and fixing flow control valve in distribution line50Nos.
977977Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc50Nos.
978978Cutting MDPE Pipes and specials true axis and finishing the end complete200Nos.
979979Distribution Line 63mm PVC Pipe
980980Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20016390R.M
981981Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
98298263 mm OD PVC Pipe 4 KSC6390R.M
983983Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
98498463 mm OD PVC Pipe 4 KSC6390R.M
985985Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
98698663 mm OD PVC Pipe 4 KSC6390R.M
987987Solvent Cement @ 0.75 Lit/100 m.47.925Lit.
988988Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
98998963mm PVC Bend24Nos
99099063mm x 50mm PVC Threaded coupler9Nos
99199163mm x 50mm PVC Tee16Nos
99299263mm End cap8Nos
993993Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
994994a.50mm GI pipe for culvert56Rm
995995b.50mm GI pipe for road portion91Rm
996996c.50mm GI Tee2Rm
997997Supply and delivery of GI specials to site of work as per IS specification with ISI marking
998998a.50mm GI Elbow page 25 sl.no 18Nos
999999b 50mm GI coupling page 25, sl.no 339Nos
10001000Laying and jointing of GI Pipes with GI specials and PVC specials etc
10011001a.50 mm dia Pipe56Rm
10021002Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1Nos
10031003Water meter Dirt BOX1Nos
10041004Water meter erection charges1Nos
10051005Provision for pit for Dual line1Nos
10061006Distribution Line 75mm PVC Pipe
10071007Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001710R.M
10081008Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
1009100975 mm OD PVC Pipe 4 KSC710R.M
10101010Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
1011101175 mm OD PVC Pipe 4 KSC710R.M
10121012Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
1013101375 mm OD PVC Pipe 4 KSC710Rm
10141014Solvent Cement @ 0.75 Lit/100 m.5.325Lit.
10151015Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
1016101675mm PVC Bend3Nos
1017101775mm PVC coupler2Nos
1018101875mm PVC Tee2Nos
1019101975mm End cap3Nos
10201020Construction of Road for Restoring the Cut Portion.
10211021Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.4.68Cu.m
10221022Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.3.12Cu.m
10231023Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.3.12Cu.m
10241024Provision for Name Board1No
10251025GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package}\n1GST Amount (in Rupees)

AI Tender Summary

OUR REF NO 25096857
AUTHORITY Local Bodies
TENDER VALUE 1.02 Crore
LAST DATE 14-08-2020
Authority
Authority Name Rural Development And Panchayats Department
Work Description Thanjavur District - Package No . 39 - Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In S . Pudur And Sathanur Panchayats In Thiruvidaimarudur Block For The Year 2020-21 .
Basic Detail
Tender No Rc.No.1325/2020/A3 dated.16.07.2020.
Bidding Type Tender
Location
City Thiruvidaimarudur
State Tamil Nadu
Key Dates
Publish Date 06 Aug 2020
Submission Date 14 Aug 2020
Open Date 14 Aug 2020
Finance
Tender Value 1.02 Crore
Tender Fee Ref. Documents
EMD 1.03 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
pkg.39.TVMR.TECHNICALBID.pdf
pkg.39.TVMR.PRICEBID.pdf
7B6A5188-AD53-4F3C-9A1E-93AD30A07D87.html
BOQ_209379.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 14, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

39

pkg.39.TVMR.TECHNICALBID.pdf

39

pkg.39.TVMR.PRICEBID.pdf

html

7B6A5188-AD53-4F3C-9A1E-93AD30A07D87.html

xls

BOQ_209379.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders