Thanjavur District - Package No . 37 - Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In Nagarasampettai And Thandalam Panchayats In Thiruvidaimarudur Block For The Year 2020-21 .
Tender Value
1.17 Crore
Estimated cost
Bid Submission
14 Aug 2020
0 days left
EMD
1.17 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvidaimarudur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Thanjavur District - Package No . 37 - Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In Nagarasampettai And Thandalam Panchayats In Thiruvidaimarudur Block For The Year 2020-21 .
BOQ
| Name of Work: THANJAVUR DISTRICT - JAL JEEVAN MISSION - 2020-2021. Part.1.Providing Functional Household Tap Connections (FHTCs) and water supply works at Kilaikattiruppu and Keezhavisalur habitations in Nagarasampettai Panchayat, Part.2.Providing Functional Household Tap Connections (FHTCs) and water supply works at Mangammalpuram, Vethappenpettai and Nagarasampettai habitations in Nagarasampettai Panchayat, Part.3.Providing Functional Household Tap Connections (FHTCs) and water supply works in Thandalam Panchayat. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Part .1. Providing Functional Household Tap Connections (FHTCs) and water supply works at Kilaikattiruppu and Keezhavisalur habitations in Nagarasampettai Panchayat. | |||
| 2 | 2 | 1. Kilaikattiruppu Habitation | |||
| 3 | 3 | Pump Room | |||
| 4 | 4 | Earth work excavation & depositing on bank with an initial lead of 10 metre & initial lift of 2 metre in Hard shift clay, stiff block cotton, hard red earth shales, murrum, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil (SS 20B) for foundation including shoring, strutting, baling out water providing danger light wherever necessary depositing the surplus earth on bank and other incedential charges etc., complete and as directed by Departmental Officers | 6.49 | Cu.m | |
| 5 | 5 | Levelling course with P.C.C 1:4:8 (one cement, four sand and eigth course aggregate) using 40 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the Departmental Officers. | 1.28 | Cu.m | |
| 6 | 6 | Earth filling in basement & sides of foundation with excavated earth including ramming and consolidation etc., complete | 2.89 | Cu.m | |
| 7 | 7 | Supply and filling the foundation and basement with clear river sand in layers complying with standard specification including consolidation and watering etc. complete and as directed by Departmental Officers. | 0.93 | Cu.m | |
| 8 | 8 | Brick work in CM 1:5 (one cement and five sand) using country bricks of size 8.75\" X 4.25\" X 2.00\" including cost of all materials, labour charges, curing etc., complete and as directed by Departmental Officers. | |||
| 9 | 9 | For foundation and basement | 4.23 | Cu.m | |
| 10 | 10 | For super structure | 3.39 | Cu.m | |
| 11 | 11 | Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.58 | Cu.m | |
| 12 | 12 | Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) excluding cost of steel fabrication,fixing in position and centring charges but including mixing,lifting and vibrating for SUNSHADE 75mm thick at wall face and 50mm thick at free end projecting 45cm from wall face moulded along with lintel etc. as directed by Departmental Officers. | 1.2 | RM | |
| 13 | 13 | Steel centering for soffits of RCC members including shuttering,strutting to the centring and providing supports etc.complete for the following members using MS Sheets of size 90cm x 60cm and BG 10 Gaugesstiffened with welded MS angles of size 25 x 25 x3mm laid over Silver Oak(country wood) joists of size 10 x 6.5 cm (spaced at about 90cm C/C) and supported by Casurania props of 10 cm to 13 cm dia. spaced at 75 cm C/C and as directed by Departmental Officers.The centring materials should be supplied and should be removed after the specified stripping time of the concrete as per IS 456/1978. | 5.31 | Sq.m | |
| 14 | 14 | Plastering with C.M. 1:5(One part of cement and Five parts of sand) with 12mm thick over brickwork portion including labour charges for mixing finishing and curing etc., complete and as directed by Departmental Officers. | 38.5 | Sq.m | |
| 15 | 15 | Special ceiling plastering for RCC Slab with C.M.1:3(One part of cement and Three parts of sand) 10mm thickover RCC surface including labour charges for mixing finishingand curing etc., complete as directed by Departmental Officers. | 4.92 | Sq.m | |
| 16 | 16 | Flooring in C C 1:4:8 (one cement ,four sand and eight HBS) 10 cm thick using 40mm HBS metal and top finished with Cement mortar 1:3 (one cement and three sand) 12 mm thick including labour charges for mixing,finishing and curing etc. complete and as directed by Departmental Officers. | 1.93 | Sq.m | |
| 17 | 17 | Supply and fixing of MS door (Single leaf) of sizes 1.00 x 2.00m in MS angle 50 x 50 x 4mm and MS flat 35 x 6mm with MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locing arrangements including two coats of approved enamel painting over one coat of primer | 1 | No. | |
| 18 | 18 | Supply, fabricating and fixing in position of RTS rods including cost of steel and binding wire etc., complete. | 0.41 | Qtl. | |
| 19 | 19 | Supply and fixing of RCC box type jolly of size 0.6 x 0.45 m | 1 | No. | |
| 20 | 20 | Painting two coats with approved cement paint over one priming coat of white cement over cement plastered wall surface and ceiling including cleaning preparing the surface and curing etc., complete (using cement paint of colour as approved by the Departm | 38.66 | Sq.m | |
| 21 | 21 | White washing two coats using fine screened shell lime for the new plastered surface for inner and outer side of the room including the cost of materials labour charges etc., complete and as directed by Departmental Officers. | 4.52 | Sq.m | |
| 22 | 22 | Weathering Coarse over RCC roof including fixing one coarse of pressed tiles etc., complete. | 5.57 | Sq.m | |
| 23 | 23 | Provision for writing TWAD Board emblem and scheme details on the side wall of the pump room | 1.5 | Sq.m | |
| 24 | 24 | Provision of lock and key for pump room and OHT ladder | 2 | Nos | |
| 25 | 25 | Levelling the site | 1 | No | |
| 26 | 26 | Pump set Cable & Electrical Room | |||
| 27 | 27 | Supply and delivery of vertical wet type submersible pumpset (5 HP) capable of discharging any of the following pumpage in lpm against noted head in m suitable for erection into the bore well/Inf. well / open well with stainless steel shaft, bronze impeller and starter. | |||
| 28 | 28 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD) | 1 | set | |
| 29 | 29 | Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 101 | 1 | set | |
| 30 | 30 | Supply, delivery of 1.1 KV Grade,PVC insulated and sheathed 3 core flat copper submersible cable with ISI marking conforming of IS 694/1990 of reputed make for submersible motor erected in borewell. | |||
| 31 | 31 | Sq.mm Copper cable page 109 II slno 2 | 45 | Metre | |
| 32 | 32 | Supply and delivery of GI medium class pipes and specials as per relevant IS as listed below. | |||
| 33 | 33 | 40mm GI Pipe (3m) length Medium SOR TWAD page 25 | 45 | Metre | |
| 34 | 34 | 40mm GI Coupling Heavy page 29 | 15 | Nos | |
| 35 | 35 | 40mm GI Bend Heavy page 29 | 3 | Nos | |
| 36 | 36 | 50mm GI Flangeset Heavy page 29 | 1 | No | |
| 37 | 37 | 40mm MS Clampset Heavy page 29 | 1 | No | |
| 38 | 38 | 50mm GM Non Return Valve page 30 | 1 | No | |
| 39 | 39 | 50 x 40mm GI reducer heavy page 26 | 1 | No | |
| 40 | 40 | 63mX50mm PVC T.Coupler page 10 | 1 | No | |
| 41 | 41 | 40mm Ball Valve/ GM Gate Valve page 30 | 1 | No | |
| 42 | 42 | Lighting the pumpromm including internal wiring with switch circute fuses etc. with the following light fittings with ISI marking. | |||
| 43 | 43 | 40W box type tube light - 1 No. | 1 | No. | |
| 44 | 44 | 100W bulb with angle holder | 2 | Nos. | |
| 45 | 45 | 100W bulk head fittings | 2 | Nos. | |
| 46 | 46 | 5 AMPS 3 pin socket with switch | 1 | No. | |
| 47 | 47 | 5 Amps switches for light(Flush type) | 4 | Nos. | |
| 48 | 48 | Providing lighting wiring using MS conduit pipes and specials with 2 runs 1.5 sqmm PVC copper wire and 1 run 12 swg GI wire for earthing for light, fans and 5A plug points etc., | 3 | nos | |
| 49 | 49 | Obtaining power supply including cost of following materials and by engaging B licence holder.EB fee for application form and deposit amount will be borne by the Board | |||
| 50 | 50 | (i) Aerial fuse board of size 15 x 10 x 6cm with 32 A aerial fuse carrier(3 Nos.) | 1 | No | |
| 51 | 51 | (iii)Wall mounting type MS cubical EB meter box with fuse carrier (3 Nos) of 32 A capacity at EB supply point.This box is also to accommodate TNEB energy meter with proper ventilation as approved by TNEB. | 1 | No | |
| 52 | 52 | (ii) Supply and laying of 7/20 size PVC insulator copper conductor cable from Aerial fuse to EB supply point etc., complete as per I.E Rules. | 60 | Metre | |
| 53 | 53 | 25mm dia GI pipe for service point | 3 | Metre | |
| 54 | 54 | 25mm dia GI Elbow | 2 | Nos. | |
| 55 | 55 | No.8 GI wire for earth(Twin earthing) | 2 | KG | |
| 56 | 56 | Stay wire 7/20 | 2 | KG | |
| 57 | 57 | 20mm GI pipe for twin earthing and cable encasing | 10 | Metre | |
| 58 | 58 | 4way nutral link | 2 | No. | |
| 59 | 59 | TW banel board (41 x 31 x 6cm) | 1 | No. | |
| 60 | 60 | Labour charges for erection of submersible pump set including fixing and jointing the submersible cable with clamps to the required depth, valves and errection panel board control room twin earthing as per I.E Rules including cost of civil works | |||
| 61 | 61 | Upto 5 HP | 1 | set | |
| 62 | 62 | Construction of Bore pit arrangements complete ect. | 1 | No | |
| 63 | 63 | Provision for Borewell | |||
| 64 | 64 | Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the Departmental Officers) including construction of mud pit. | |||
| 65 | 65 | 0m to 60m depth | 60 | Metre | |
| 66 | 66 | Above 60m depth | 15 | Metre | |
| 67 | 67 | Reaming of 150mm Dia Borewell to 300mm Dia Borewell as directed at site | |||
| 68 | 68 | 0m to 60m depth | 60 | Metre | |
| 69 | 69 | Above 60m depth | 15 | Metre | |
| 70 | 70 | Labour charges for inserting casing pipe supply & packing of pebbles | 75 | Metre | |
| 71 | 71 | Supply & delivery of 150mm Dia PVC Plain Casing pipe as per IS 12818 / 2010 | 54 | Nos | |
| 72 | 72 | Supply & delivery of 150mm Dia PVC Slotted Casing pipe as per IS 12818 / 2010 | 21 | Nos | |
| 73 | 73 | Charges for developing the borewell using air compressor in hours | 8 | Nos | |
| 74 | 74 | OHT - Service Reservoir 30000 lit | |||
| 75 | 75 | Earth work excavation & depositing on bank with an initial lead of 10 metre & initial lift of 2 metre in Hard shift clay, stiff block cotton, hard red earth shales, murrum, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil (SS 20B) for foundation including shoring, strutting, baling out water providing danger light wherever necessary depositing the surplus earth on bank and other incedential charges etc., complete and as directed by Departmental Officers | |||
| 76 | 76 | First depth of 2m From 0 to 2 m below GL | 58.55 | Cu.m | |
| 77 | 77 | Second depth of 2m From 2m to 4 m below GL(For Column Footing) | 13.12 | Cu.m | |
| 78 | 78 | Sand filling for foundation with clear river sand including cost of sand, watering ,ramming and consolidation etc complete as directed by Departmental Officers | 8.75 | Cu.m | |
| 79 | 79 | Plain Cement Concrete 1:4:8 (one cement, four sand and eight hard granite broken stone of 40mm size ISS gauge) for foundation and footing including mixing, placing, ramming ,finishing curing etc. complete in accordance with standard specification and as directed by the Departmental Officers. | 4.37 | Cu.m | |
| 80 | 80 | Reinforced Cement Concrete Mix M30 grade using 10mm & 20mm Hard blue granite Broken stone (machine crushed) excluding the cost of RTS rods for reinforcement and centering, strutting, shuttering but including cost of all materials mixing, laying, Vibrating the concrete with mechanical vibrators, ramming, consolidating, finishing and curing etc., Complete and as directed by the Departmental Officers. | |||
| 81 | 81 | Below 1.5m from GL | 13.52 | Cu.m | |
| 82 | 82 | 0m to 1.50m below GL | 1.75 | Cu.m | |
| 83 | 83 | 0m to 4.50m above GL | 2.83 | Cu.m | |
| 84 | 84 | 4.50 m to 7.32 m above GL | 2.22 | Cu.m | |
| 85 | 85 | 7.32 m to 10.98 m above GL | 2.53 | Cu.m | |
| 86 | 86 | 10.98 m to 14.64 m above GL | 11.4 | Cu.m | |
| 87 | 87 | 14.64 m to 18.30 m above GL | 3.09 | Cu.m | |
| 88 | 88 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | |||
| 89 | 89 | Below GL | 19.94 | Sq.m | |
| 90 | 90 | From GL to 3.30m | 25.92 | Sq.m | |
| 91 | 91 | From 5.30m to 6.30m above GL | 11.91 | Sq.m | |
| 92 | 92 | From 8.30m to 9.30m above GL | 11.91 | Sq.m | |
| 93 | 93 | From 11.30m to 12.30m | 40.03 | Sq.m | |
| 94 | 94 | Square Column Below GL and upto 3.30m above GL | 21.42 | Sq.m | |
| 95 | 95 | 3.31m to 4.30m ht | 4.08 | Sq.m | |
| 96 | 96 | 4.31m to 5.30m ht | 4.8 | Sq.m | |
| 97 | 97 | 5.31m to 6.30m ht | 3.99 | Sq.m | |
| 98 | 98 | 6.31m to 7.30m ht | 4.8 | Sq.m | |
| 99 | 99 | 7.31m to 8.30m ht | 4.8 | Sq.m | |
| 100 | 100 | 8.31m to 9.30m ht | 3.99 | Sq.m | |
| 101 | 101 | 9.31m to 10.30m ht | 4.8 | Sq.m | |
| 102 | 102 | 10.31m to 11.30m ht | 4.8 | Sq.m | |
| 103 | 103 | 11.31m to 12.30m ht | 0.72 | Sq.m | |
| 104 | 104 | 11.30m to 12.30m (Floor slab above platform) | 2.48 | Sq.m | |
| 105 | 105 | 12.30m to 13.30m | 26.2 | Sq.m | |
| 106 | 106 | 13.30m to 14.30m | 26.2 | Sq.m | |
| 107 | 107 | 14.30m to 15.30m | 26.86 | Sq.m | |
| 108 | 108 | Supplying, cutting, bending, tying, fabricating and placing in position of steel rods for all RCC works including cost of steel and binding wire etc.( The steel should conform to the relevant ISspecification and supplied with test certificate Fe. 415 grade as per IS specification No.1786/1985 and as amended from time to time) delivery at site of work including loading, freight, unloading, stacking, transit insurance charges, taxes etc. complete.and as directed by the Departmental Officers. | 51.03 | Qtl | |
| 109 | 109 | Painting two coats with approved cement paint over one priming coat of white cement over cement plastered wall surface and ceiling including cleaning preparing the surface and curing etc., complete (using cement paint of colour as approved by the Departmental officer) and as directed by the Departmental Officers. | 166.57 | Sq.m | |
| 110 | 110 | Fabrication, supply, delivery and fixing of outside MS Ladder of 45cm clear wide made out of 50 mm x 50mm x 6mm MS angle for both sides and for steps at 30cm C/C welded jointed etc ., for I staging from GL to 1st level brace (weight 4.5kg/m) IInd and IIIrd staging upto floor slab and IVth staging from floor slab to roof top. Supply, delivery and fixing of 32 mm GI pipes medium for hand rails from I stage to IVth stage. RCC M30 Grade mix for Landing slab 5 nos. at Ground Level- 1No. and above Ground Level - 4Nos. Supply and fixing of 32mm GI pipe medium for hand rails for the Landing slab. Supplying and fixing of MS Base plate of 100mm X 100mm X 6mm thick for fixing Anchore fastener bolt for fixing of hand rails at Landing slab and MS Ladder providing locking arrangements with two coats of approved enamel paint over one coat of red oxide paint as per approved Type Design and as directed by Departmental Officers. | 1 | No | |
| 111 | 111 | Providing and fixing of RCC inner access ladder in RCC 1:11/2 :3 (one cement,one and half sand and three aggregate) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centring,shuttering charges, mixing concrete,curing etc. to required height and clear width of 45 cm consisting of 2 nos. of vertical post of 10 cm x 15 cm and step slab of 25mm x 25mm etc.complete and as directed by Departmental Officers. | 1 | No | |
| 112 | 112 | Providing 110mm PVC vent cowl arrangements mosquito proof nylon net and as directed by Departmental Officers | 2 | Nos | |
| 113 | 113 | Supply and fixing of cut stone of size 0.30m x 0.30m x 0.15m in CM 1;3(one cement and three sand) below inlet pipe for Service Reservoir as directed by Departmental Officers. | 1 | Nos | |
| 114 | 114 | Providing manhole cover of size 0.60 x 0.60M in RCC 1:1.5:3 with suitable reinforcement and 50x50x6mm MS angle fixed along edges and as directed by Departmental Officers | 1 | No | |
| 115 | 115 | Painting emblem on the SR with enamel paint as per Board's specification and as directed by Departmental Officers | 2 | Sq.m | |
| 116 | 116 | Pipe connection arrangements for inlet,outlet,scour and overflow etc. including cost of pipes, specials, valve, labour charges for lifting, aligning, cutting, threading ,fixing and painting of GI pipes with two coats of approved quality enamal paint etc. complete as detailed below. | |||
| 117 | 117 | 65mm GI pipes for inlet connection | 18 | Metre | |
| 118 | 118 | 65mm GI pipes for over flow & rain water harvesting pipe | 16 | Metre | |
| 119 | 119 | 50mm GI pipes for scour pipe | 13 | Metre | |
| 120 | 120 | 65mm GI pipe for delivery pipe | 13 | Metre | |
| 121 | 121 | 90mm PVC Threaded coupler | 1 | Nos | |
| 122 | 122 | 63mm PVC Threaded coupler | 2 | Nos | |
| 123 | 123 | 65mm dia GI Tee | 2 | Nos | |
| 124 | 124 | 65mm dia GI bend 90 | 5 | Nos | |
| 125 | 125 | 65mm dia GI bend (short) | 1 | Nos | |
| 126 | 126 | 65mm GI coupler | 5 | Nos | |
| 127 | 127 | 65mm GI union | 2 | Nos | |
| 128 | 128 | 65mm GI Elbow | 1 | Nos | |
| 129 | 129 | 50mm GI union | 2 | Nos | |
| 130 | 130 | 50mm GI Elbow | 1 | Nos | |
| 131 | 131 | 65mm GI Tee | 2 | Nos | |
| 132 | 132 | 65x50mm GI reducer | 1 | Nos | |
| 133 | 133 | 75mmx63mm PVC reducer | 2 | Nos | |
| 134 | 134 | 65mm GM gate valve | 2 | Nos | |
| 135 | 135 | 50mm GM gate valve | 1 | Nos | |
| 136 | 136 | 63 mm PVC 4Ksc Pipe | 6 | Metre | |
| 137 | 137 | Refilling the foundation with excavated earth including consolidation as directed by the Departmental Officers | 43.54 | Cu.m | |
| 138 | 138 | Labour charges for GI pipe connection to the OHT, for inlet, outlet, overflow and scour arrangements including cutting and threading, earth work excavation & refilling. | 1 | No. | |
| 139 | 139 | Providing Hand rails over the Roof slab by using 32 mm GI Pipe with 40mm x 6mm MS Flat and fixied with 12mm dia Fastner Bolt 75mm long and as directed by Departmental Officers | 1 | No | |
| 140 | 140 | Providing Hand rails over the Standing Platform by using 32 mm GI Pipe with 40mm x 6mm MS Flat and fixied with 12mm dia Fastner Bolt 75mm long and as directed by Departmental Officers | 4 | Nos | |
| 141 | 141 | Provision for Levelling the Site and SBC test | 1 | No | |
| 142 | 142 | Distribution Line 63mm PVC Pipe | |||
| 143 | 143 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1553 | R.M | |
| 144 | 144 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 145 | 145 | 63 mm OD PVC Pipe 4 KSC | 1553 | R.M | |
| 146 | 146 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 147 | 147 | 63 mm OD PVC Pipe 4 KSC | 1553 | R.M | |
| 148 | 148 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 149 | 149 | 63 mm OD PVC Pipe 4 KSC | 1553 | R.M | |
| 150 | 150 | Solvent Cement @ 0.75 Lit/100 m. | 11.648 | Lit. | |
| 151 | 151 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 152 | 152 | 63mm PVC Bend | 12 | Nos | |
| 153 | 153 | 63mm x 50mm PVC Threaded coupler | 21 | Nos | |
| 154 | 154 | 63mm x 50mm PVC Tee | 15 | Nos | |
| 155 | 155 | 63mm End cap | 16 | Nos | |
| 156 | 156 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 157 | 157 | a.50mm GI pipe | 40 | Metre. | |
| 158 | 158 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 159 | 159 | a.50mm GI Elbow page 25 sl.no 1 | 10 | Nos | |
| 160 | 160 | b 80mm GI coupling page 25, sl.no 3 | 12 | Nos | |
| 161 | 161 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 162 | 162 | a.50 mm dia Pipe | 40 | Metre. | |
| 163 | 163 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 164 | 164 | Water meter Dirt BOX | 1 | No | |
| 165 | 165 | Water meter erection charges | 1 | No | |
| 166 | 166 | Provision for pit for Dual line | 1 | No | |
| 167 | 167 | Provision for GM Gate Valve 50 mm | 2 | Nos | |
| 168 | 168 | Distribution Line 75mm PVC Pipe | |||
| 169 | 169 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 173 | R.M | |
| 170 | 170 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 171 | 171 | 75 mm OD PVC Pipe 4 KSC | 173 | R.M | |
| 172 | 172 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 173 | 173 | 75 mm OD PVC Pipe 4 KSC | 173 | R.M | |
| 174 | 174 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 175 | 175 | 75 mm OD PVC Pipe 4 KSC | 173 | Rm | |
| 176 | 176 | Solvent Cement @ 0.75 Lit/100 m. | 1.298 | Lit. | |
| 177 | 177 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 178 | 178 | 75mm PVC Bend | 2 | Nos | |
| 179 | 179 | 75mm PVC coupler | 10 | Nos | |
| 180 | 180 | 75mm PVC Tee | 5 | Nos | |
| 181 | 181 | 75mm End cap | 6 | Nos | |
| 182 | 182 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 183 | 183 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 47 | Metre | |
| 184 | 184 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 47 | Nos. | |
| 185 | 185 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 47 | Nos. | |
| 186 | 186 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 47 | Nos. | |
| 187 | 187 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 47 | Nos. | |
| 188 | 188 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 189 | 189 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 5 | Metre | |
| 190 | 190 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 5 | Nos. | |
| 191 | 191 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 5 | Nos. | |
| 192 | 192 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 5 | Nos. | |
| 193 | 193 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 5 | Nos. | |
| 194 | 194 | NEW FHTC - 63 x 20mm | |||
| 195 | 195 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 30 | Nos. | |
| 196 | 196 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 30 | Nos. | |
| 197 | 197 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 30 | Nos. | |
| 198 | 198 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 90 | Nos. | |
| 199 | 199 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 240 | Metre. | |
| 200 | 200 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 180 | R.M | |
| 201 | 201 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 240 | Metre. | |
| 202 | 202 | Supply & Jointing 20 mm Waste Not tap | 30 | Nos. | |
| 203 | 203 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 30 | Nos. | |
| 204 | 204 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 30 | Nos. | |
| 205 | 205 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 120 | Nos. | |
| 206 | 206 | NEW FHTC - 75 x 20mm | |||
| 207 | 207 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 3 | Nos. | |
| 208 | 208 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 3 | Nos. | |
| 209 | 209 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 3 | Nos. | |
| 210 | 210 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 9 | Nos. | |
| 211 | 211 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 24 | Metre. | |
| 212 | 212 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 18 | R.M | |
| 213 | 213 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 24 | Metre. | |
| 214 | 214 | Supply & Jointing 20 mm Waste Not tap | 3 | Nos. | |
| 215 | 215 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 3 | Nos. | |
| 216 | 216 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 3 | Nos. | |
| 217 | 217 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 12 | Nos. | |
| 218 | 218 | Repairs to 10000 Litre OHT at Kilaikattiruppu | |||
| 219 | 219 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 2.7 | Sq.m | |
| 220 | 220 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 18.04 | Sq.m | |
| 221 | 221 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 2.02 | Cu.m | |
| 222 | 222 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 122.2 | Sq.m | |
| 223 | 223 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 224 | 224 | Provision for RCC Inner Ladder | 1 | No | |
| 225 | 225 | Manhole cover 60 x 60 cm (heavy duty) with frame s.no.192(Building materials) TWAAD SOR. | 1 | No | |
| 226 | 226 | 50mm G.I Gate Valve | 2 | Nos | |
| 227 | 227 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 228 | 228 | Supply and delivery of 80mm GI Pipes. | 74 | Metre. | |
| 229 | 229 | 80mm G.I Gate Valve | 1 | No | |
| 230 | 230 | Air Compressor | 4 | Nos | |
| 231 | 231 | Construction of Road for Restoring the Cut Portion. | |||
| 232 | 232 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 1.44 | Cu.m | |
| 233 | 233 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 0.96 | Cu.m | |
| 234 | 234 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 0.96 | Cu.m | |
| 235 | 235 | Provision for Name Board | 1 | Nos | |
| 236 | 236 | 2. Keelavisaloor habitation | |||
| 237 | 237 | DISTRIBUTION MAIN - NEW LINE | |||
| 238 | 238 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 2734 | R.M | |
| 239 | 239 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 240 | 240 | 63 mm OD PVC Pipe 4 KSC | 2734 | R.M | |
| 241 | 241 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 242 | 242 | 63 mm OD PVC Pipe 4 KSC | 2734 | R.M | |
| 243 | 243 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 244 | 244 | 63 mm OD PVC Pipe 4 KSC | 2734 | R.M | |
| 245 | 245 | Solvent Cement @ 0.75 Lit/100 m. | 20.505 | Lit. | |
| 246 | 246 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 247 | 247 | 63mm PVC Bend | 34 | Nos | |
| 248 | 248 | 63mm x 50mm PVC Threaded coupler | 18 | Nos | |
| 249 | 249 | 63mm x 50mm PVC Tee | 18 | Nos | |
| 250 | 250 | 63mm End cap | 21 | Nos | |
| 251 | 251 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 252 | 252 | a.50mm GI pipe | 30 | Metre. | |
| 253 | 253 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 254 | 254 | a.50mm GI Elbow page 25 sl.no 1 | 4 | Nos | |
| 255 | 255 | b 80mm GI coupling page 25, sl.no 3 | 6 | Nos | |
| 256 | 256 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 257 | 257 | a.50 mm dia Pipe | 30 | Metre. | |
| 258 | 258 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 259 | 259 | Water meter Dirt BOX | 1 | No | |
| 260 | 260 | Water meter erection charges | 1 | No | |
| 261 | 261 | Provision for pit for Dual line | 1 | No | |
| 262 | 262 | Provision for GM Gate Valve 50 mm | 2 | Nos | |
| 263 | 263 | Distribution Line 75mm PVC Pipe | |||
| 264 | 264 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 304 | R.M | |
| 265 | 265 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 266 | 266 | 75 mm OD PVC Pipe 4 KSC | 304 | R.M | |
| 267 | 267 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 268 | 268 | 75 mm OD PVC Pipe 4 KSC | 304 | R.M | |
| 269 | 269 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 270 | 270 | 75 mm OD PVC Pipe 4 KSC | 304 | Rm | |
| 271 | 271 | Solvent Cement @ 0.75 Lit/100 m. | 2.28 | Lit. | |
| 272 | 272 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 273 | 273 | 75mm PVC Bend | 4 | Nos | |
| 274 | 274 | 75mm PVC coupler | 2 | Nos | |
| 275 | 275 | 75mm PVC Tee | 2 | Nos | |
| 276 | 276 | 75mm End cap | 2 | Nos | |
| 277 | 277 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 278 | 278 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 30 | Metre | |
| 279 | 279 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 30 | Nos. | |
| 280 | 280 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 30 | Nos. | |
| 281 | 281 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 30 | Nos. | |
| 282 | 282 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 30 | Nos. | |
| 283 | 283 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 284 | 284 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 3 | Metre | |
| 285 | 285 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 3 | Nos. | |
| 286 | 286 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 3 | Nos. | |
| 287 | 287 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 3 | Nos. | |
| 288 | 288 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 3 | Nos. | |
| 289 | 289 | NEW FHTC - 63 x 20mm (including Government Building) | |||
| 290 | 290 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 36 | Nos. | |
| 291 | 291 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 36 | Nos. | |
| 292 | 292 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 36 | Nos. | |
| 293 | 293 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 108 | Nos. | |
| 294 | 294 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 288 | Metre. | |
| 295 | 295 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 216 | R.M | |
| 296 | 296 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 288 | Metre. | |
| 297 | 297 | Supply & Jointing 20 mm Waste Not tap | 36 | Nos. | |
| 298 | 298 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 36 | Nos. | |
| 299 | 299 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 36 | Nos. | |
| 300 | 300 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 144 | Nos. | |
| 301 | 301 | NEW FHTC - 75 x 20mm | |||
| 302 | 302 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 4 | Metre. | |
| 303 | 303 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 4 | Nos. | |
| 304 | 304 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 4 | Nos. | |
| 305 | 305 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 12 | Nos. | |
| 306 | 306 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 32 | Metre. | |
| 307 | 307 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 24 | R.M | |
| 308 | 308 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 32 | Metre. | |
| 309 | 309 | Supply & Jointing 20 mm Waste Not tap | 4 | Nos. | |
| 310 | 310 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 4 | Nos. | |
| 311 | 311 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 4 | Nos. | |
| 312 | 312 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 16 | Nos. | |
| 313 | 313 | Repairs to 30000 Litre OHT at Indra Nagar in Nagarasampettai | |||
| 314 | 314 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 12.76 | Sq.m | |
| 315 | 315 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 316 | 316 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 317 | 317 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 318 | 318 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 147.27 | Sq.m | |
| 319 | 319 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 320 | 320 | Provision for Inner Ladder | 1 | No | |
| 321 | 321 | 65mm G.I Gate Valve | 2 | Nos | |
| 322 | 322 | Air Compressor | 2 | Hour | |
| 323 | 323 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 324 | 324 | Supply and delivery of 50mm GI Pipes. | 50 | Metre. | |
| 325 | 325 | Construction of Road for Restoring the Cut Portion. | |||
| 326 | 326 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 2.16 | Cu.m | |
| 327 | 327 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 1.44 | Cu.m | |
| 328 | 328 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 1.44 | Cu.m | |
| 329 | 329 | Provision for Name Board | 1 | No | |
| 330 | 330 | Part.2.Providing Functional Household Tap Connections (FHTCs) and water supply works at Mangammalpuram, Vethappenpettai and Nagarasampettai habitations in Nagarasampettai Panchayat . | |||
| 331 | 331 | 1. Mangammalpuram Habitation | |||
| 332 | 332 | Distribution Line 63mm PVC Pipe | |||
| 333 | 333 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 3122 | R.M | |
| 334 | 334 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 335 | 335 | 63 mm OD PVC Pipe 4 KSC | 3122 | R.M | |
| 336 | 336 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 337 | 337 | 63 mm OD PVC Pipe 4 KSC | 3122 | R.M | |
| 338 | 338 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 339 | 339 | 63 mm OD PVC Pipe 4 KSC | 3122 | R.M | |
| 340 | 340 | Solvent Cement @ 0.75 Lit/100 m. | 23.415 | Lit. | |
| 341 | 341 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 342 | 342 | 63mm PVC Bend | 24 | Nos | |
| 343 | 343 | 63mm x 50mm PVC Threaded coupler | 36 | Nos | |
| 344 | 344 | 63mm x 50mm PVC Tee | 12 | Nos | |
| 345 | 345 | 63mm End cap | 10 | Nos | |
| 346 | 346 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 347 | 347 | a.50mm GI pipe | 30 | Metre. | |
| 348 | 348 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 349 | 349 | a.50mm GI Elbow page 25 sl.no 1 | 10 | Nos | |
| 350 | 350 | b 80mm GI coupling page 25, sl.no 3 | 8 | Nos | |
| 351 | 351 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 352 | 352 | a.50 mm dia Pipe | 30 | Metre. | |
| 353 | 353 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 354 | 354 | Water meter Dirt BOX | 1 | No | |
| 355 | 355 | Water meter erection charges | 1 | No | |
| 356 | 356 | Provision for pit for Dual line | 1 | No | |
| 357 | 357 | Provision for GM Gate Valve 50 mm | 2 | No | |
| 358 | 358 | Distribution Line 75mm PVC Pipe | |||
| 359 | 359 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 347 | R.M | |
| 360 | 360 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 361 | 361 | 75 mm OD PVC Pipe 4 KSC | 347 | R.M | |
| 362 | 362 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 363 | 363 | 75 mm OD PVC Pipe 4 KSC | 347 | R.M | |
| 364 | 364 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 365 | 365 | 75 mm OD PVC Pipe 4 KSC | 347 | Rm | |
| 366 | 366 | Solvent Cement @ 0.75 Lit/100 m. | 2.603 | Lit. | |
| 367 | 367 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 368 | 368 | 75mm PVC Bend | 3 | Nos | |
| 369 | 369 | 75mm PVC coupler | 8 | Nos | |
| 370 | 370 | 75mm PVC Tee | 5 | Nos | |
| 371 | 371 | 75mm End cap | 4 | Nos | |
| 372 | 372 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 373 | 373 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 35 | Metre | |
| 374 | 374 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 35 | Nos. | |
| 375 | 375 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 35 | Nos. | |
| 376 | 376 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 35 | Nos. | |
| 377 | 377 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 35 | Nos. | |
| 378 | 378 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 379 | 379 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 4 | Metre | |
| 380 | 380 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 4 | Nos. | |
| 381 | 381 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 4 | Nos. | |
| 382 | 382 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 4 | Nos. | |
| 383 | 383 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 4 | Nos. | |
| 384 | 384 | NEW FHTC - 63 x 20mm | |||
| 385 | 385 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 36 | Nos. | |
| 386 | 386 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 36 | Nos. | |
| 387 | 387 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 36 | Nos. | |
| 388 | 388 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 108 | Nos. | |
| 389 | 389 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 288 | Metre. | |
| 390 | 390 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 216 | R.M | |
| 391 | 391 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 288 | Metre. | |
| 392 | 392 | Supply & Jointing 20 mm Waste Not tap | 36 | Nos. | |
| 393 | 393 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 36 | Nos. | |
| 394 | 394 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 36 | Nos. | |
| 395 | 395 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 144 | Nos. | |
| 396 | 396 | NEW FHTC - 75 x 20mm | |||
| 397 | 397 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 4 | Nos. | |
| 398 | 398 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 4 | Nos. | |
| 399 | 399 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 4 | Nos. | |
| 400 | 400 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 12 | Nos. | |
| 401 | 401 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 32 | Metre. | |
| 402 | 402 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 24 | R.M | |
| 403 | 403 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 32 | Metre. | |
| 404 | 404 | Supply & Jointing 20 mm Waste Not tap | 4 | Nos. | |
| 405 | 405 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 4 | Nos. | |
| 406 | 406 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 4 | Nos. | |
| 407 | 407 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 16 | Nos. | |
| 408 | 408 | Repairs to 10000 Litre OHT at Rettiyar Street | |||
| 409 | 409 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 7.07 | Sq.m | |
| 410 | 410 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 10.72 | Sq.m | |
| 411 | 411 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 412 | 412 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 1.22 | Cu.m | |
| 413 | 413 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 115.07 | Sq.m | |
| 414 | 414 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 415 | 415 | Provision for RCC Inner Ladder | 1 | No | |
| 416 | 416 | 50mm G.I Gate Valve | 2 | Nos | |
| 417 | 417 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 418 | 418 | Supply and delivery of 50mm GI Pipes. | 40 | Metre. | |
| 419 | 419 | Repairs to 10000 Litre OHT at AD Street Nagarasampettai | |||
| 420 | 420 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 7.07 | Sq.m | |
| 421 | 421 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 10.72 | Sq.m | |
| 422 | 422 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 423 | 423 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 1.22 | Cu.m | |
| 424 | 424 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 115.07 | Sq.m | |
| 425 | 425 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 426 | 426 | Provision for RCC Inner Ladder | 1 | No | |
| 427 | 427 | 50mm G.I Gate Valve | 2 | Nos | |
| 428 | 428 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 429 | 429 | Supply and delivery of 50mm GI Pipes. | 50 | Metre. | |
| 430 | 430 | Construction of Road for Restoring the Cut Portion. | |||
| 431 | 431 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 2.88 | Cu.m | |
| 432 | 432 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 1.92 | Cu.m | |
| 433 | 433 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 1.92 | Cu.m | |
| 434 | 434 | Provision for Name board | 1 | No | |
| 435 | 435 | 2. Vethappanpettai Habitation | |||
| 436 | 436 | Distribution Line 63mm PVC Pipe | |||
| 437 | 437 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1777 | R.M | |
| 438 | 438 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 439 | 439 | 63 mm OD PVC Pipe 4 KSC | 1777 | R.M | |
| 440 | 440 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 441 | 441 | 63 mm OD PVC Pipe 4 KSC | 1777 | R.M | |
| 442 | 442 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 443 | 443 | 63 mm OD PVC Pipe 4 KSC | 1777 | R.M | |
| 444 | 444 | Solvent Cement @ 0.75 Lit/100 m. | 13.33 | Lit. | |
| 445 | 445 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 446 | 446 | 63mm PVC Bend | 18 | Nos | |
| 447 | 447 | 63mm x 50mm PVC Threaded coupler | 8 | Nos | |
| 448 | 448 | 63mm x 50mm PVC Tee | 16 | Nos | |
| 449 | 449 | 63mm End cap | 15 | Nos | |
| 450 | 450 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 451 | 451 | a.50mm GI pipe | 35 | Metre. | |
| 452 | 452 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 453 | 453 | a.50mm GI Elbow page 25 sl.no 1 | 4 | Nos | |
| 454 | 454 | b 80mm GI coupling page 25, sl.no 3 | 6 | Nos | |
| 455 | 455 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 456 | 456 | a.50 mm dia Pipe | 35 | Metre. | |
| 457 | 457 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 458 | 458 | Water meter Dirt BOX | 1 | No | |
| 459 | 459 | Water meter erection charges | 1 | No | |
| 460 | 460 | Provision for pit for Dual line | 1 | No | |
| 461 | 461 | Provision for GM gate value 50 mm | 2 | Nos | |
| 462 | 462 | Distribution Line 75mm PVC Pipe | |||
| 463 | 463 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 198 | R.M | |
| 464 | 464 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 465 | 465 | 75 mm OD PVC Pipe 4 KSC | 198 | R.M | |
| 466 | 466 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 467 | 467 | 75 mm OD PVC Pipe 4 KSC | 198 | R.M | |
| 468 | 468 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 469 | 469 | 75 mm OD PVC Pipe 4 KSC | 198 | Rm | |
| 470 | 470 | Solvent Cement @ 0.75 Lit/100 m. | 1.485 | Lit. | |
| 471 | 471 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 472 | 472 | 75mm PVC Bend | 4 | Nos | |
| 473 | 473 | 75mm PVC coupler | 2 | Nos | |
| 474 | 474 | 75mm PVC Tee | 2 | Nos | |
| 475 | 475 | 75mm End cap | 2 | Nos | |
| 476 | 476 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 477 | 477 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 62 | Metre | |
| 478 | 478 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 62 | Nos. | |
| 479 | 479 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 62 | Nos. | |
| 480 | 480 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 62 | Nos. | |
| 481 | 481 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 62 | Nos. | |
| 482 | 482 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 483 | 483 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 7 | Metre | |
| 484 | 484 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 7 | Nos. | |
| 485 | 485 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 7 | Nos. | |
| 486 | 486 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 7 | Nos. | |
| 487 | 487 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 7 | Nos. | |
| 488 | 488 | NEW FHTC - 63 x 20mm | |||
| 489 | 489 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 25 | Nos. | |
| 490 | 490 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 25 | Nos. | |
| 491 | 491 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 25 | Nos. | |
| 492 | 492 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 75 | Nos. | |
| 493 | 493 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 200 | Metre. | |
| 494 | 494 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 150 | R.M | |
| 495 | 495 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 200 | Metre. | |
| 496 | 496 | Supply & Jointing 20 mm Waste Not tap | 25 | Nos. | |
| 497 | 497 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 25 | Nos. | |
| 498 | 498 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 25 | Nos. | |
| 499 | 499 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 100 | Nos. | |
| 500 | 500 | NEW FHTC - 75 x 20mm | |||
| 501 | 501 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 3 | Nos. | |
| 502 | 502 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 3 | Nos. | |
| 503 | 503 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 3 | Nos. | |
| 504 | 504 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 9 | Nos. | |
| 505 | 505 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 24 | Metre. | |
| 506 | 506 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 18 | R.M | |
| 507 | 507 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 24 | Metre. | |
| 508 | 508 | Supply & Jointing 20 mm Waste Not tap | 3 | Nos. | |
| 509 | 509 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 3 | Nos. | |
| 510 | 510 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 3 | Nos. | |
| 511 | 511 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 12 | Nos. | |
| 512 | 512 | Repairs to 10000 Litre OHT at Vedhappanpettai AD Street Nagarasampettai | |||
| 513 | 513 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 7.07 | Sq.m | |
| 514 | 514 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 10.72 | Sq.m | |
| 515 | 515 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 516 | 516 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 1.22 | Cu.m | |
| 517 | 517 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 115.07 | Sq.m | |
| 518 | 518 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 519 | 519 | Provision for Inner Ladder | 1 | No | |
| 520 | 520 | 50mm G.I Gate Valve | 2 | Nos | |
| 521 | 521 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 522 | 522 | Supply and delivery of 50mm GI Pipes. | 40 | Metre. | |
| 523 | 523 | Construction of Road for Restoring the Cut Portion. | |||
| 524 | 524 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 2.16 | Cu.m | |
| 525 | 525 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 1.44 | Cu.m | |
| 526 | 526 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 1.44 | Cu.m | |
| 527 | 527 | Provision for Name board | 1 | No | |
| 528 | 528 | 2. Nagarasampettai Habitation | |||
| 529 | 529 | Distribution Line 63mm PVC Pipe | |||
| 530 | 530 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 4891 | R.M | |
| 531 | 531 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 532 | 532 | 63 mm OD PVC Pipe 4 KSC | 4891 | R.M | |
| 533 | 533 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 534 | 534 | 63 mm OD PVC Pipe 4 KSC | 4891 | R.M | |
| 535 | 535 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 536 | 536 | 63 mm OD PVC Pipe 4 KSC | 4891 | R.M | |
| 537 | 537 | Solvent Cement @ 0.75 Lit/100 m. | 36.683 | Lit. | |
| 538 | 538 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 539 | 539 | 63mm PVC Bend | 45 | Metre. | |
| 540 | 540 | 63mm x 50mm PVC Threaded coupler | 37 | Metre. | |
| 541 | 541 | 63mm x 50mm PVC Tee | 30 | Metre. | |
| 542 | 542 | 63mm End cap | 36 | Metre. | |
| 543 | 543 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 544 | 544 | a.50mm GI pipe | 40 | Metre. | |
| 545 | 545 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 546 | 546 | a.50mm GI Elbow page 25 sl.no 1 | 6 | Metre. | |
| 547 | 547 | b 80mm GI coupling page 25, sl.no 3 | 12 | Metre. | |
| 548 | 548 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 549 | 549 | a.50 mm dia Pipe | 40 | Metre. | |
| 550 | 550 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | Metre. | |
| 551 | 551 | Water meter Dirt BOX | 1 | Metre. | |
| 552 | 552 | Water meter erection charges | 1 | Metre. | |
| 553 | 553 | Provision for pit for Dual line | 1 | Metre. | |
| 554 | 554 | Provision for GM gate value 50 mm | 2 | Metre. | |
| 555 | 555 | Distribution Line 75mm PVC Pipe | |||
| 556 | 556 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 543 | R.M | |
| 557 | 557 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 558 | 558 | 75 mm OD PVC Pipe 4 KSC | 543 | R.M | |
| 559 | 559 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 560 | 560 | 75 mm OD PVC Pipe 4 KSC | 543 | R.M | |
| 561 | 561 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 562 | 562 | 75 mm OD PVC Pipe 4 KSC | 543 | Rm | |
| 563 | 563 | Solvent Cement @ 0.75 Lit/100 m. | 4.073 | Lit. | |
| 564 | 564 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 565 | 565 | 75mm PVC Bend | 8 | Nos | |
| 566 | 566 | 75mm PVC coupler | 10 | Nos | |
| 567 | 567 | 75mm PVC Tee | 4 | Nos | |
| 568 | 568 | 75mm End cap | 5 | Nos | |
| 569 | 569 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 570 | 570 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 173 | Metre | |
| 571 | 571 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 173 | Nos. | |
| 572 | 572 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 173 | Nos. | |
| 573 | 573 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 173 | Nos. | |
| 574 | 574 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 173 | Nos. | |
| 575 | 575 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 576 | 576 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 19 | Metre | |
| 577 | 577 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 19 | Nos. | |
| 578 | 578 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 19 | Nos. | |
| 579 | 579 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 19 | Nos. | |
| 580 | 580 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 19 | Nos. | |
| 581 | 581 | NEW FHTC - 63 x 20mm | |||
| 582 | 582 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 93 | Nos. | |
| 583 | 583 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 93 | Nos. | |
| 584 | 584 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 93 | Nos. | |
| 585 | 585 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 279 | Nos. | |
| 586 | 586 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 744 | Metre. | |
| 587 | 587 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 558 | R.M | |
| 588 | 588 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 744 | Metre. | |
| 589 | 589 | Supply & Jointing 20 mm Waste Not tap | 93 | Nos. | |
| 590 | 590 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 93 | Nos. | |
| 591 | 591 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 93 | Nos. | |
| 592 | 592 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 372 | Nos. | |
| 593 | 593 | NEW FHTC - 75 x 20mm | |||
| 594 | 594 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 10 | Nos. | |
| 595 | 595 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 10 | Nos. | |
| 596 | 596 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 10 | Nos. | |
| 597 | 597 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 30 | Nos. | |
| 598 | 598 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 80 | Metre. | |
| 599 | 599 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 60 | R.M | |
| 600 | 600 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 80 | Metre. | |
| 601 | 601 | Supply & Jointing 20 mm Waste Not tap | 10 | Nos. | |
| 602 | 602 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 10 | Nos. | |
| 603 | 603 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 10 | Nos. | |
| 604 | 604 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 40 | Nos. | |
| 605 | 605 | Repairs to 30000 Litre OHT at East Street Nagarasampettai | |||
| 606 | 606 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 12.76 | Sq.m | |
| 607 | 607 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 608 | 608 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 609 | 609 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 610 | 610 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 147.27 | Sq.m | |
| 611 | 611 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 612 | 612 | Provision for Inner Ladder | 1 | Ls | |
| 613 | 613 | 65mm G.I Gate Valve | 2 | Nos | |
| 614 | 614 | Air Compressor | 2 | Hour | |
| 615 | 615 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 616 | 616 | Supply and delivery of 50mm GI Pipes. | 46 | Metre. | |
| 617 | 617 | Repairs to 60000 Litre OHT at South Street Nagarasampettai | |||
| 618 | 618 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 24.6 | Sq.m | |
| 619 | 619 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 30.85 | Sq.m | |
| 620 | 620 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 621 | 621 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.54 | Cu.m | |
| 622 | 622 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 132.82 | Sq.m | |
| 623 | 623 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 624 | 624 | Manhole cover 60 x 60 cm (heavy duty) with frame s.no.192(Building materials) TWAAD SOR. | 1 | No | |
| 625 | 625 | 65mm G.I Gate Valve | 2 | Nos | |
| 626 | 626 | Air Compressor | 2 | Hour | |
| 627 | 627 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 20.41 | Sq.m | |
| 628 | 628 | Supply and delivery of 80mm GI Pipes. | 40 | Metre. | |
| 629 | 629 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977 | |||
| 630 | 630 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD) | 1 | set | |
| 631 | 631 | Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 101 | 1 | set | |
| 632 | 632 | Construction of Road for Restoring the Cut Portion. | |||
| 633 | 633 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 2.16 | Cu.m | |
| 634 | 634 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 1.44 | Cu.m | |
| 635 | 635 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 1.44 | Cu.m | |
| 636 | 636 | Provision for Name board | 1 | No | |
| 637 | 637 | Part.3. Providing Functional Household Tap Connections (FHTCs) and water supply works in Thandalam Panchayat. | |||
| 638 | 638 | 1. Thandalam Habitation | |||
| 639 | 639 | Distribution Line 63mm PVC Pipe | |||
| 640 | 640 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1614 | R.M | |
| 641 | 641 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 642 | 642 | 63 mm OD PVC Pipe 4 KSC | 1614 | R.M | |
| 643 | 643 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 644 | 644 | 63 mm OD PVC Pipe 4 KSC | 1614 | R.M | |
| 645 | 645 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 646 | 646 | 63 mm OD PVC Pipe 4 KSC | 1614 | R.M | |
| 647 | 647 | Solvent Cement @ 0.75 Lit/100 m. | 12.105 | Lit. | |
| 648 | 648 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 649 | 649 | 63mm PVC Bend | 30 | Nos | |
| 650 | 650 | 63mm x 50mm PVC Threaded coupler | 24 | Nos | |
| 651 | 651 | 63mm x 50mm PVC Tee | 18 | Nos | |
| 652 | 652 | 63mm End cap | 22 | Nos | |
| 653 | 653 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 654 | 654 | a.50mm GI pipe | 40 | Metre. | |
| 655 | 655 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 656 | 656 | a.50mm GI Elbow page 25 sl.no 1 | 8 | Nos | |
| 657 | 657 | b 80mm GI coupling page 25, sl.no 3 | 10 | Nos | |
| 658 | 658 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 659 | 659 | a.50 mm dia Pipe | 40 | Metre. | |
| 660 | 660 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 661 | 661 | Water meter Dirt BOX | 1 | No | |
| 662 | 662 | Water meter erection charges | 1 | No | |
| 663 | 663 | Provision for pit for Dual line | 1 | No | |
| 664 | 664 | Provision for GM Gate Valve 50 mm | 2 | No | |
| 665 | 665 | Distribution Line 75mm PVC Pipe | |||
| 666 | 666 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 423 | R.M | |
| 667 | 667 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 668 | 668 | 75 mm OD PVC Pipe 4 KSC | 423 | R.M | |
| 669 | 669 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 670 | 670 | 75 mm OD PVC Pipe 4 KSC | 423 | R.M | |
| 671 | 671 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 672 | 672 | 75 mm OD PVC Pipe 4 KSC | 423 | Rm | |
| 673 | 673 | Solvent Cement @ 0.75 Lit/100 m. | 3.173 | Lit. | |
| 674 | 674 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 675 | 675 | 75mm PVC Bend | 4 | Nos | |
| 676 | 676 | 75mm PVC coupler | 6 | Nos | |
| 677 | 677 | 75mm PVC Tee | 6 | Nos | |
| 678 | 678 | 75mm End cap | 4 | Nos | |
| 679 | 679 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 680 | 680 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 61 | Metre | |
| 681 | 681 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 61 | Nos. | |
| 682 | 682 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 61 | Nos. | |
| 683 | 683 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 61 | Nos. | |
| 684 | 684 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 61 | Nos. | |
| 685 | 685 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 686 | 686 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 7 | Metre | |
| 687 | 687 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 7 | Nos. | |
| 688 | 688 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 7 | Nos. | |
| 689 | 689 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 7 | Nos. | |
| 690 | 690 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 7 | Nos. | |
| 691 | 691 | NEW FHTC - 63 x 20mm | |||
| 692 | 692 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 55 | Nos. | |
| 693 | 693 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 55 | Nos. | |
| 694 | 694 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 55 | Nos. | |
| 695 | 695 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 165 | Nos. | |
| 696 | 696 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 440 | Metre. | |
| 697 | 697 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 330 | R.M | |
| 698 | 698 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 440 | Metre. | |
| 699 | 699 | Supply & Jointing 20 mm Waste Not tap | 55 | Nos. | |
| 700 | 700 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 55 | Nos. | |
| 701 | 701 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 55 | Nos. | |
| 702 | 702 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 220 | Nos. | |
| 703 | 703 | NEW FHTC - 75 x 20mm | |||
| 704 | 704 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 6 | Nos. | |
| 705 | 705 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 6 | Nos. | |
| 706 | 706 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 6 | Nos. | |
| 707 | 707 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 18 | Nos. | |
| 708 | 708 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 48 | Metre. | |
| 709 | 709 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 36 | R.M | |
| 710 | 710 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 48 | Metre. | |
| 711 | 711 | Supply & Jointing 20 mm Waste Not tap | 6 | Nos. | |
| 712 | 712 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 6 | Nos. | |
| 713 | 713 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 6 | Nos. | |
| 714 | 714 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 24 | Nos. | |
| 715 | 715 | Repairs to 10000 Litre OHT Thandalam Main Road | |||
| 716 | 716 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 7.07 | Sq.m | |
| 717 | 717 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 10.72 | Sq.m | |
| 718 | 718 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 719 | 719 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 1.22 | Cu.m | |
| 720 | 720 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 115.07 | Sq.m | |
| 721 | 721 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 722 | 722 | Provision for Inner Ladder | 1 | No | |
| 723 | 723 | 50mm G.I Gate Valve | 2 | Nos | |
| 724 | 724 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 725 | 725 | Supply and delivery of 50mm GI Pipes. | 45 | Metre. | |
| 726 | 726 | Repairs to 10000 Litre OHT Thandalam MariyammanKoil | |||
| 727 | 727 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 7.07 | Sq.m | |
| 728 | 728 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 10.72 | Sq.m | |
| 729 | 729 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 730 | 730 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 1.22 | Cu.m | |
| 731 | 731 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 115.07 | Sq.m | |
| 732 | 732 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 733 | 733 | Provision for Inner Ladder | 1 | No | |
| 734 | 734 | 50mm G.I Gate Valve | 2 | Nos | |
| 735 | 735 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 736 | 736 | Supply and delivery of 50mm GI Pipes. | 52 | Metre. | |
| 737 | 737 | Construction of Road for Restoring the Cut Portion. | |||
| 738 | 738 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 2.16 | Cu.m | |
| 739 | 739 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 1.44 | Cu.m | |
| 740 | 740 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 1.44 | Cu.m | |
| 741 | 741 | Provision for Name board | 1 | No | |
| 742 | 742 | 2. Kozhiyakudi Habitation | |||
| 743 | 743 | Distribution Line 63mm PVC Pipe | |||
| 744 | 744 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 3805 | R.M | |
| 745 | 745 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 746 | 746 | 63 mm OD PVC Pipe 4 KSC | 3805 | R.M | |
| 747 | 747 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 748 | 748 | 63 mm OD PVC Pipe 4 KSC | 3805 | R.M | |
| 749 | 749 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 750 | 750 | 63 mm OD PVC Pipe 4 KSC | 3805 | R.M | |
| 751 | 751 | Solvent Cement @ 0.75 Lit/100 m. | 28.54 | Lit. | |
| 752 | 752 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 753 | 753 | 63mm PVC Bend | 45 | Nos | |
| 754 | 754 | 63mm x 50mm PVC Threaded coupler | 38 | Nos | |
| 755 | 755 | 63mm x 50mm PVC Tee | 24 | Nos | |
| 756 | 756 | 63mm End cap | 19 | Nos | |
| 757 | 757 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 758 | 758 | a.50mm GI pipe | 30 | Metre. | |
| 759 | 759 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 760 | 760 | a.50mm GI Elbow page 25 sl.no 1 | 6 | Nos | |
| 761 | 761 | b 80mm GI coupling page 25, sl.no 3 | 8 | Nos | |
| 762 | 762 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 763 | 763 | a.50 mm dia Pipe | 30 | Metre. | |
| 764 | 764 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 765 | 765 | Water meter Dirt BOX | 1 | No | |
| 766 | 766 | Water meter erection charges | 1 | No | |
| 767 | 767 | Provision for pit for Dual line | 1 | No | |
| 768 | 768 | Provision for GM gate value 50 mm | 2 | Nos | |
| 769 | 769 | Distribution Line 75mm PVC Pipe | |||
| 770 | 770 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 423 | R.M | |
| 771 | 771 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 772 | 772 | 75 mm OD PVC Pipe 4 KSC | 423 | R.M | |
| 773 | 773 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 774 | 774 | 75 mm OD PVC Pipe 4 KSC | 423 | R.M | |
| 775 | 775 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 776 | 776 | 75 mm OD PVC Pipe 4 KSC | 423 | Rm | |
| 777 | 777 | Solvent Cement @ 0.75 Lit/100 m. | 3.173 | Lit. | |
| 778 | 778 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 779 | 779 | 75mm PVC Bend | 4 | Nos | |
| 780 | 780 | 75mm PVC coupler | 6 | Nos | |
| 781 | 781 | 75mm PVC Tee | 6 | Nos | |
| 782 | 782 | 75mm End cap | 4 | Nos | |
| 783 | 783 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 784 | 784 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 68 | Metre | |
| 785 | 785 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 68 | Nos. | |
| 786 | 786 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 68 | Nos. | |
| 787 | 787 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 68 | Nos. | |
| 788 | 788 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 68 | Nos. | |
| 789 | 789 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 790 | 790 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 8 | Cu.m | |
| 791 | 791 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 8 | Nos. | |
| 792 | 792 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 8 | Nos. | |
| 793 | 793 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 8 | Nos. | |
| 794 | 794 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 8 | Nos. | |
| 795 | 795 | NEW FHTC - 63 x 20mm | |||
| 796 | 796 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 111 | Nos. | |
| 797 | 797 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 111 | Nos. | |
| 798 | 798 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 111 | Nos. | |
| 799 | 799 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 333 | Nos. | |
| 800 | 800 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 888 | Metre. | |
| 801 | 801 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 666 | R.M | |
| 802 | 802 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 888 | Metre. | |
| 803 | 803 | Supply & Jointing 20 mm Waste Not tap | 111 | Nos. | |
| 804 | 804 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 111 | Nos. | |
| 805 | 805 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 111 | Nos. | |
| 806 | 806 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 444 | Nos. | |
| 807 | 807 | NEW FHTC - 75 x 20mm | |||
| 808 | 808 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 12 | Nos. | |
| 809 | 809 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 12 | Nos. | |
| 810 | 810 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 12 | Nos. | |
| 811 | 811 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 36 | Nos. | |
| 812 | 812 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 96 | Metre. | |
| 813 | 813 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 72 | R.M | |
| 814 | 814 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 96 | Metre. | |
| 815 | 815 | Supply & Jointing 20 mm Waste Not tap | 12 | Nos. | |
| 816 | 816 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 12 | Nos. | |
| 817 | 817 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 12 | Nos. | |
| 818 | 818 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 48 | Nos. | |
| 819 | 819 | Repairs to 30000 Litre OHT Kozhikudi Sivankoil Street | |||
| 820 | 820 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 12.76 | Sq.m | |
| 821 | 821 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 822 | 822 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 823 | 823 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 824 | 824 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 147.27 | Sq.m | |
| 825 | 825 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 826 | 826 | Provision for Inner Ladder | 1 | Nos | |
| 827 | 827 | 65mm G.I Gate Valve | 2 | Nos | |
| 828 | 828 | Air Compressor | 2 | Hour | |
| 829 | 829 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 830 | 830 | Supply and delivery of 50mm GI Pipes. | 60 | Metre. | |
| 831 | 831 | Repairs to 30000 Litre OHT Kozhikudi AD Street | |||
| 832 | 832 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 12.76 | Sq.m | |
| 833 | 833 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 834 | 834 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 835 | 835 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 836 | 836 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 147.27 | Sq.m | |
| 837 | 837 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 838 | 838 | Provision for Inner Ladder | 1 | No | |
| 839 | 839 | 65mm G.I Gate Valve | 2 | Nos | |
| 840 | 840 | Air Compressor | 2 | Hour | |
| 841 | 841 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 842 | 842 | Supply and delivery of 50mm GI Pipes. | 52 | Metre. | |
| 843 | 843 | Construction of Road for Restoring the Cut Portion. | |||
| 844 | 844 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 4.32 | Cu.m | |
| 845 | 845 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 2.88 | Cu.m | |
| 846 | 846 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 2.88 | Cu.m | |
| 847 | 847 | Provision for Name board | 1 | No | |
| 848 | 848 | 3. Kombacheri Habitation | |||
| 849 | 849 | Distribution Line 63mm PVC Pipe | |||
| 850 | 850 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1111 | R.M | |
| 851 | 851 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 852 | 852 | 63 mm OD PVC Pipe 4 KSC | 1111 | R.M | |
| 853 | 853 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 854 | 854 | 63 mm OD PVC Pipe 4 KSC | 1111 | R.M | |
| 855 | 855 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 856 | 856 | 63 mm OD PVC Pipe 4 KSC | 1111 | R.M | |
| 857 | 857 | Solvent Cement @ 0.75 Lit/100 m. | 8.333 | Lit. | |
| 858 | 858 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 859 | 859 | 63mm PVC Bend | 22 | Nos | |
| 860 | 860 | 63mm x 50mm PVC Threaded coupler | 18 | Nos | |
| 861 | 861 | 63mm x 50mm PVC Tee | 22 | Nos | |
| 862 | 862 | 63mm End cap | 10 | Nos | |
| 863 | 863 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 864 | 864 | a.50mm GI pipe | 30 | Metre. | |
| 865 | 865 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 866 | 866 | a.50mm GI Elbow page 25 sl.no 1 | 6 | Nos | |
| 867 | 867 | b 80mm GI coupling page 25, sl.no 3 | 8 | Nos | |
| 868 | 868 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 869 | 869 | a.50 mm dia Pipe | 30 | Metre. | |
| 870 | 870 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 871 | 871 | Water meter Dirt BOX | 1 | No | |
| 872 | 872 | Water meter erection charges | 1 | No | |
| 873 | 873 | Provision for pit for Dual line | 1 | No | |
| 874 | 874 | Provision for GM gate value 50 mm | 2 | Nos | |
| 875 | 875 | Distribution Line 75mm PVC Pipe | |||
| 876 | 876 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 123 | R.M | |
| 877 | 877 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 878 | 878 | 75 mm OD PVC Pipe 4 KSC | 123 | R.M | |
| 879 | 879 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 880 | 880 | 75 mm OD PVC Pipe 4 KSC | 123 | R.M | |
| 881 | 881 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 882 | 882 | 75 mm OD PVC Pipe 4 KSC | 123 | Rm | |
| 883 | 883 | Solvent Cement @ 0.75 Lit/100 m. | 0.923 | Lit. | |
| 884 | 884 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 885 | 885 | 75mm PVC Bend | 4 | Nos | |
| 886 | 886 | 75mm PVC coupler | 6 | Nos | |
| 887 | 887 | 75mm PVC Tee | 4 | Nos | |
| 888 | 888 | 75mm End cap | 4 | Nos | |
| 889 | 889 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 890 | 890 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 24 | Metre | |
| 891 | 891 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 24 | Nos. | |
| 892 | 892 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 24 | Nos. | |
| 893 | 893 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 24 | Nos. | |
| 894 | 894 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 24 | Nos. | |
| 895 | 895 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 896 | 896 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 3 | Metre | |
| 897 | 897 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 3 | Nos. | |
| 898 | 898 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 3 | Nos. | |
| 899 | 899 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 3 | Nos. | |
| 900 | 900 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 3 | Nos. | |
| 901 | 901 | NEW FHTC - 63 x 20mm | |||
| 902 | 902 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 20 | Nos. | |
| 903 | 903 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 20 | Nos. | |
| 904 | 904 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 20 | Nos. | |
| 905 | 905 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 60 | Nos. | |
| 906 | 906 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 160 | Metre. | |
| 907 | 907 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 120 | R.M | |
| 908 | 908 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 160 | Metre. | |
| 909 | 909 | Supply & Jointing 20 mm Waste Not tap | 20 | Nos. | |
| 910 | 910 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 20 | Nos. | |
| 911 | 911 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 20 | Nos. | |
| 912 | 912 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 80 | Nos. | |
| 913 | 913 | NEW FHTC - 75 x 20mm | |||
| 914 | 914 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 2 | Nos. | |
| 915 | 915 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 2 | Nos. | |
| 916 | 916 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 2 | Nos. | |
| 917 | 917 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 6 | Nos. | |
| 918 | 918 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 16 | Metre. | |
| 919 | 919 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 12 | R.M | |
| 920 | 920 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 16 | Metre. | |
| 921 | 921 | Supply & Jointing 20 mm Waste Not tap | 2 | Nos. | |
| 922 | 922 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 2 | Nos. | |
| 923 | 923 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 2 | Nos. | |
| 924 | 924 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 8 | Nos. | |
| 925 | 925 | Repairs to 30000 Litre OHT Kombacheri | |||
| 926 | 926 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 12.76 | Sq.m | |
| 927 | 927 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 928 | 928 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 929 | 929 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 930 | 930 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 147.27 | Sq.m | |
| 931 | 931 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 932 | 932 | Provision for Inner Ladder | 1 | Ls | |
| 933 | 933 | 65mm G.I Gate Valve | 2 | Nos | |
| 934 | 934 | Air Compressor | 2 | Hour | |
| 935 | 935 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 936 | 936 | Supply and delivery of 50mm GI Pipes. | 50 | Metre. | |
| 937 | 937 | Construction of Road for Restoring the Cut Portion. | |||
| 938 | 938 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 1.44 | Cu.m | |
| 939 | 939 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 0.96 | Cu.m | |
| 940 | 940 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 0.96 | Cu.m | |
| 941 | 941 | Provision for Name board | 1 | No | |
| 942 | 942 | 4. Aathikulam Habitation | |||
| 943 | 943 | Distribution Line 63mm PVC Pipe | |||
| 944 | 944 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 2070 | R.M | |
| 945 | 945 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 946 | 946 | 63 mm OD PVC Pipe 4 KSC | 2070 | R.M | |
| 947 | 947 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 948 | 948 | 63 mm OD PVC Pipe 4 KSC | 2070 | R.M | |
| 949 | 949 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 950 | 950 | 63 mm OD PVC Pipe 4 KSC | 2070 | R.M | |
| 951 | 951 | Solvent Cement @ 0.75 Lit/100 m. | 15.525 | Lit. | |
| 952 | 952 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 953 | 953 | 63mm PVC Bend | 38 | Metre. | |
| 954 | 954 | 63mm x 50mm PVC Threaded coupler | 42 | Metre. | |
| 955 | 955 | 63mm x 50mm PVC Tee | 45 | Metre. | |
| 956 | 956 | 63mm End cap | 12 | Metre. | |
| 957 | 957 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 958 | 958 | a.50mm GI pipe | 48 | Metre. | |
| 959 | 959 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 960 | 960 | a.50mm GI Elbow page 25 sl.no 1 | 6 | Metre. | |
| 961 | 961 | b 80mm GI coupling page 25, sl.no 3 | 8 | Metre. | |
| 962 | 962 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 963 | 963 | a.50 mm dia Pipe | 48 | Metre. | |
| 964 | 964 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 965 | 965 | Water meter Dirt BOX | 1 | No | |
| 966 | 966 | Water meter erection charges | 1 | No | |
| 967 | 967 | Provision for pit for Dual line | 1 | No | |
| 968 | 968 | Provision for GM gate value 50 mm | 2 | Nos | |
| 969 | 969 | Distribution Line 75mm PVC Pipe | |||
| 970 | 970 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 230 | R.M | |
| 971 | 971 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 972 | 972 | 75 mm OD PVC Pipe 4 KSC | 230 | R.M | |
| 973 | 973 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 974 | 974 | 75 mm OD PVC Pipe 4 KSC | 230 | R.M | |
| 975 | 975 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 976 | 976 | 75 mm OD PVC Pipe 4 KSC | 230 | Rm | |
| 977 | 977 | Solvent Cement @ 0.75 Lit/100 m. | 1.725 | Lit. | |
| 978 | 978 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 979 | 979 | 75mm PVC Bend | 4 | Nos | |
| 980 | 980 | 75mm PVC coupler | 8 | Nos | |
| 981 | 981 | 75mm PVC Tee | 4 | Nos | |
| 982 | 982 | 75mm End cap | 2 | Nos | |
| 983 | 983 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 984 | 984 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 29 | Metre | |
| 985 | 985 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 29 | Nos. | |
| 986 | 986 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 29 | Nos. | |
| 987 | 987 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 29 | Nos. | |
| 988 | 988 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 29 | Nos. | |
| 989 | 989 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 990 | 990 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 3 | Metre | |
| 991 | 991 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 3 | Nos. | |
| 992 | 992 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 3 | Nos. | |
| 993 | 993 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 3 | Nos. | |
| 994 | 994 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 3 | Nos. | |
| 995 | 995 | NEW FHTC - 63 x 20mm (including Government Building) | |||
| 996 | 996 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 34 | Nos. | |
| 997 | 997 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 34 | Nos. | |
| 998 | 998 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 34 | Nos. | |
| 999 | 999 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 102 | Nos. | |
| 1000 | 1000 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 272 | Metre. | |
| 1001 | 1001 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 204 | R.M | |
| 1002 | 1002 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 272 | Metre. | |
| 1003 | 1003 | Supply & Jointing 20 mm Waste Not tap | 34 | Metre. | |
| 1004 | 1004 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 34 | Nos. | |
| 1005 | 1005 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 34 | Each | |
| 1006 | 1006 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 136 | Nos. | |
| 1007 | 1007 | NEW FHTC - 75 x 20mm | |||
| 1008 | 1008 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 4 | Nos. | |
| 1009 | 1009 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 4 | Nos. | |
| 1010 | 1010 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 4 | Nos. | |
| 1011 | 1011 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 12 | Nos. | |
| 1012 | 1012 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 32 | Metre. | |
| 1013 | 1013 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 24 | R.M | |
| 1014 | 1014 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 32 | Metre. | |
| 1015 | 1015 | Supply & Jointing 20 mm Waste Not tap | 4 | Nos. | |
| 1016 | 1016 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 4 | Nos. | |
| 1017 | 1017 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 4 | Nos. | |
| 1018 | 1018 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 16 | Nos. | |
| 1019 | 1019 | Repairs to 30000 Litre OHT Aathikulam | |||
| 1020 | 1020 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 12.76 | Sq.m | |
| 1021 | 1021 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 1022 | 1022 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 1023 | 1023 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 1024 | 1024 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 146.3 | Sq.m | |
| 1025 | 1025 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 1026 | 1026 | Provision for Inner Ladder | 1 | No | |
| 1027 | 1027 | 65mm G.I Gate Valve | 2 | Nos | |
| 1028 | 1028 | Air Compressor | 2 | Hour | |
| 1029 | 1029 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 1030 | 1030 | Supply and delivery of 50mm GI Pipes. | 46 | Metre. | |
| 1031 | 1031 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977 | |||
| 1032 | 1032 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD) | 1 | set | |
| 1033 | 1033 | Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 101 | 1 | set | |
| 1034 | 1034 | Construction of Road for Restoring the Cut Portion. | |||
| 1035 | 1035 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 2.88 | Cu.m | |
| 1036 | 1036 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 1.92 | Cu.m | |
| 1037 | 1037 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 1.92 | Cu.m | |
| 1038 | 1038 | Provision for Name board | 1 | No | |
| 1039 | 1039 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package}\n | 1 | GST Amount (in Rupees) |
AI Tender Summary
Tender Timeline
Aug 06, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedAug 14, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 14, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender