Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In Govindapuram , Malaiyappanallur And Srinivasanallur Panchayats In Thiruvidaimarudur Block Of Thanjavur District-Year 2020-21 .
Tender Overview
Project Description
Thanjavur District - Package No . 35 - Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In Govindapuram , Malaiyappanallur And Srinivasanallur Panchayats In Thiruvidaimarudur Block Of Thanjavur District-Year 2020-21 .
BOQ
| Name of Work: THANJAVUR DISTRICT - JAL JEEVAN MISSION - 2020-2021. Part .1. Providing Functional Household Tap Connections (FHTCs) and water supply works in Govindapuram Panchayat., Part.2.Providing Functional Household Tap Connections (FHTCs) and water supply works in Malaiyappanallur Panchayat. Part.3.Providing Functional Household Tap Connections (FHTCs) and water supply works in Sinivasanallur Panchayat | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Part .1. Providing Functional Household Tap Connections (FHTCs) and water supply works in Govindapuram Panchayat. | |||
| 2 | 2 | 1. Govindapuram Habitation | |||
| 3 | 3 | Distribution Line 63mm PVC Pipe | |||
| 4 | 4 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 5686 | R.M | |
| 5 | 5 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 6 | 6 | 63 mm OD PVC Pipe 4 KSC | 5686 | R.M | |
| 7 | 7 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 8 | 8 | 63 mm OD PVC Pipe 4 KSC | 5686 | R.M | |
| 9 | 9 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 10 | 10 | 63 mm OD PVC Pipe 4 KSC | 5686 | R.M | |
| 11 | 11 | Solvent Cement @ 0.75 Lit/100 m. | 42.65 | Lit. | |
| 12 | 12 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 13 | 13 | 63mm PVC Bend | 42 | Nos | |
| 14 | 14 | 63mm x 50mm PVC Threaded coupler | 21 | Nos | |
| 15 | 15 | 63mm x 50mm PVC Tee | 22 | Nos | |
| 16 | 16 | 63mm End cap | 31 | Nos | |
| 17 | 17 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 18 | 18 | a.50mm GI pipe | 91 | Rm | |
| 19 | 19 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 20 | 20 | a.50mm GI Elbow page 25 sl.no 1 | 15 | Nos | |
| 21 | 21 | b 50mm GI coupling page 25, sl.no 3 | 12 | Nos | |
| 22 | 22 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 23 | 23 | a.50 mm dia Pipe | 91 | Rm | |
| 24 | 24 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 25 | 25 | Water meter Dirt BOX | 1 | No | |
| 26 | 26 | Water meter erection charges | 1 | No | |
| 27 | 27 | Provision for pit for Dual line | 1 | No | |
| 28 | 28 | Distribution Line 75mm PVC Pipe | |||
| 29 | 29 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 632 | R.M | |
| 30 | 30 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 31 | 31 | 75 mm OD PVC Pipe 4 KSC | 632 | R.M | |
| 32 | 32 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 33 | 33 | 75 mm OD PVC Pipe 4 KSC | 632 | R.M | |
| 34 | 34 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 35 | 35 | 75 mm OD PVC Pipe 4 KSC | 632 | Rm | |
| 36 | 36 | Solvent Cement @ 0.75 Lit/100 m. | 4.74 | Lit. | |
| 37 | 37 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 38 | 38 | 75mm PVC Bend | 12 | Nos | |
| 39 | 39 | 75mm PVC coupler | 9 | Nos | |
| 40 | 40 | 75mm PVC Tee | 8 | Nos | |
| 41 | 41 | 75mm End cap | 4 | Nos | |
| 42 | 42 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 43 | 43 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 259 | Rm | |
| 44 | 44 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 259 | Nos. | |
| 45 | 45 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 259 | Nos. | |
| 46 | 46 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 259 | Nos. | |
| 47 | 47 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 259 | Nos. | |
| 48 | 48 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 49 | 49 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 29 | Cu.m | |
| 50 | 50 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 29 | Nos. | |
| 51 | 51 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 29 | Nos. | |
| 52 | 52 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 29 | Nos. | |
| 53 | 53 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 29 | Nos. | |
| 54 | 54 | NEW FHTC - 63 x 20mm | |||
| 55 | 55 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 137 | Nos. | |
| 56 | 56 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 137 | Nos. | |
| 57 | 57 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 137 | Nos. | |
| 58 | 58 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 411 | Nos. | |
| 59 | 59 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 1096 | Rm | |
| 60 | 60 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 822 | Rm | |
| 61 | 61 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 1096 | Rm | |
| 62 | 62 | Supply & Jointing 20 mm Waste Not tap | 137 | Metre. | |
| 63 | 63 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 137 | Nos. | |
| 64 | 64 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 137 | Nos. | |
| 65 | 65 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 548 | Nos. | |
| 66 | 66 | NEW FHTC - 75 x 20mm | |||
| 67 | 67 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 15 | Nos. | |
| 68 | 68 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 15 | Nos. | |
| 69 | 69 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 15 | Nos. | |
| 70 | 70 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 45 | Nos. | |
| 71 | 71 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 120 | Rm | |
| 72 | 72 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 90 | Rm | |
| 73 | 73 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 120 | Rm | |
| 74 | 74 | Supply & Jointing 20 mm Waste Not tap | 15 | Nos. | |
| 75 | 75 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 15 | Nos. | |
| 76 | 76 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 15 | Nos. | |
| 77 | 77 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 60 | Nos. | |
| 78 | 78 | Repairs to 10000 Litre OHT at Govindapuram | |||
| 79 | 79 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 100.62 | Sq.m | |
| 80 | 80 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 81 | 81 | Gate Valve 50mm | 2 | Nos | |
| 82 | 82 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 83 | 83 | Repairs to 10000 Litre OHT at Govindapuram | |||
| 84 | 84 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 124.24 | Sq.m | |
| 85 | 85 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 86 | 86 | Gate Valve 50mm | 2 | Nos | |
| 87 | 87 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 88 | 88 | Repairs to 30000 Litre OHT at Govindapuram Muthaliyar Street | |||
| 89 | 89 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 66.3 | Sq.m | |
| 90 | 90 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 159.82 | Sq.m | |
| 91 | 91 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 92 | 92 | Provision for RCC Inner Ladder | 1 | Nos | |
| 93 | 93 | Gate Valve 50mm | 2 | Nos | |
| 94 | 94 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 95 | 95 | Repairs to 30000 Litre OHT at Govindapuram Mariyammankoil Street | |||
| 96 | 96 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 63.05 | Sq.m | |
| 97 | 97 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 159.82 | Sq.m | |
| 98 | 98 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 99 | 99 | Provision for RCC Inner Ladder | 1 | Nos | |
| 100 | 100 | Gate Valve 50mm | 2 | Nos | |
| 101 | 101 | GI Pipe 50mm | 6 | Rm | |
| 102 | 102 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 103 | 103 | Repairs to 30000 Litre OHT at near Govindapuram Panchayat Office | |||
| 104 | 104 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 143.77 | Sq.m | |
| 105 | 105 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 106 | 106 | Provision for RCC Inner Ladder | 1 | Nos | |
| 107 | 107 | Manhole cover 60 x 60 cm (heavy duty) with frame s.no.192(Building materials) TWAAD SOR. | 1 | Nos | |
| 108 | 108 | Gate Valve 80mm | 2 | Nos | |
| 109 | 109 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 20.41 | Sq.m | |
| 110 | 110 | Provision for OHT Borewell | |||
| 111 | 111 | Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit. | |||
| 112 | 112 | 0m to 60m depth | 60 | Rm | |
| 113 | 113 | Reaming of 150mm Dia Borewell to 300mm Dia Borewell as directed at site | |||
| 114 | 114 | 0m to 60m depth | 60 | Rm | |
| 115 | 115 | Labour charges for inserting casing pipe supply & packing of pebbles | 60 | Rm | |
| 116 | 116 | Supply & delivery of 150mm Dia PVC Plain Casing pipe as per IS 12818 / 2010 | 45 | Nos | |
| 117 | 117 | Supply & delivery of 150mm Dia PVC Slotted Casing pipe as per IS 12818 / 2010 | 15 | Nos | |
| 118 | 118 | Charges for developing the borewell using air compressor in hours | 8 | Hours | |
| 119 | 119 | Pump Room | |||
| 120 | 120 | Earth work excavation & depositing on bank with an initial lead of 10 metre & initial lift of 2 metre in Hard shift clay, stiff block cotton, hard red earth shales, murrum, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil (SS 20B) for foundation including shoring, strutting, baling out water providing danger light wherever necessary depositing the surplus earth on bank and other incedential charges etc., complete and as directed by TWAD board Officers | 12.98 | Cu.m | |
| 121 | 121 | Levelling course with P.C.C 1:4:8 (one cement, four sand and eigth course aggregate) using 40 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the Departmental Officers. | 2.56 | Cu.m | |
| 122 | 122 | Earth filling in basement & sides of foundation with excavated earth including ramming and consolidation etc., complete | 5.78 | Cu.m | |
| 123 | 123 | Supply and filling the foundation and basement with clear river sand in layers complying with standard specification including consolidation and watering etc. complete and as directed by Departmental Officers. | 1.86 | Cu.m | |
| 124 | 124 | Brick work in CM 1:5 (one cement and five sand) using country bricks of size 8.75\" X 4.25\" X 2.00\" including cost of all materials, labour charges, curing etc., complete and as directed by Departmental Officers. | |||
| 125 | 125 | For foundation and basement | 8.46 | Cu.m | |
| 126 | 126 | For super structure | 6.78 | Cu.m | |
| 127 | 127 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 1.16 | Cu.m | |
| 128 | 128 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) excluding cost of steel fabrication,fixing in position and centring charges but including mixing,lifting and vibrating for SUNSHADE 75mm thick at wall face and 50mm thick at free end projecting 45cm from wall face moulded along with lintel etc. as directed by Departmental Officers. | 2.4 | Cu.m | |
| 129 | 129 | Steel centering for soffits of RCC members including shuttering,strutting to the centring and providing supports etc.complete for the following members using MS Sheets of size 90cm x 60cm and BG 10 Gaugesstiffened with welded MS angles of size 25 x 25 x3mm laid over Silver Oak(country wood) joists of size 10 x 6.5 cm (spaced at about 90cm C/C) and supported by Casurania props of 10 cm to 13 cm dia. spaced at 75 cm C/C and as directed by Departmental Officers.The centring materials should be supplied and should be removed after the specified stripping time of the concrete as per IS 456/1978. | 10.62 | Sq.m | |
| 130 | 130 | Plastering with C.M. 1:5(One part of cement and Five parts of sand) with 12mm thick over brickwork portion including labour charges for mixing finishing and curing etc., complete and as directed by Departmental Officers. | 77 | Sq.m | |
| 131 | 131 | Special ceiling plastering for RCC Slab with C.M.1:3(One part of cement and Three parts of sand) 10mm thickover RCC surface including labour charges for mixing finishingand curing etc., complete as directed by Departmental Officers. | 9.84 | Sq.m | |
| 132 | 132 | Flooring in C C 1:4:8 (one cement ,four sand and eight HBS) 10 cm thick using 40mm HBS metal and top finished with Cement mortar 1:3 (one cement and three sand) 12 mm thick including labour charges for mixing,finishing and curing etc. complete and as directed by Departmental Officers. | 3.86 | Sq.m | |
| 133 | 133 | Supply and fixing of MS door (Single leaf) of sizes 1.00 x 2.00m in MS angle 50 x 50 x 4mm and MS flat 35 x 6mm with MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locing arrangements including two coats of approved enamel painting over one coat of primer | 2 | No. | |
| 134 | 134 | Supply, fabricating and fixing in position of RTS rods including cost of steel and binding wire etc., complete. | 0.82 | Qtl. | |
| 135 | 135 | Supply and fixing of RCC box type jolly of size 0.6 x 0.45 m | 2 | Nos | |
| 136 | 136 | Painting two coats with approved cement paint over one priming coat of white cement over cement plastered wall surface and ceiling including cleaning preparing the surface and curing etc., complete (using cement paint of colour as approved by the Departm | 77.32 | Sq.m | |
| 137 | 137 | White washing two coats using fine screened shell lime for the new plastered surface for inner and outer side of the room including the cost of materials labour charges etc., complete and as directed by Departmental Officers. | 9.04 | Sq.m | |
| 138 | 138 | Weathering Coarse over RCC roof including fixing one coarse of pressed tiles etc., complete. | 11.14 | Sq.m | |
| 139 | 139 | Provision for writing TWAD Board emblem and scheme details on the side wall of the pump room | 2 | Sq.m | |
| 140 | 140 | Provision of lock and key for pump room and OHT ladder | 4 | Nos | |
| 141 | 141 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977 | |||
| 142 | 142 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD) | 1 | set | |
| 143 | 143 | Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 101 | 1 | set | |
| 144 | 144 | Construction of Road for Restoring the Cut Portion. | |||
| 145 | 145 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 4.68 | Cu.m | |
| 146 | 146 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 3.12 | Cu.m | |
| 147 | 147 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 3.12 | Cu.m | |
| 148 | 148 | Provision for Name Board | 1 | Nos | |
| 149 | 149 | 2. Vanapuram Habitation | |||
| 150 | 150 | Distribution Line 63mm PVC Pipe | |||
| 151 | 151 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1785 | R.M | |
| 152 | 152 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 153 | 153 | 63 mm OD PVC Pipe 4 KSC | 1785 | R.M | |
| 154 | 154 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 155 | 155 | 63 mm OD PVC Pipe 4 KSC | 1785 | R.M | |
| 156 | 156 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 157 | 157 | 63 mm OD PVC Pipe 4 KSC | 1785 | R.M | |
| 158 | 158 | Solvent Cement @ 0.75 Lit/100 m. | 13.388 | Lit. | |
| 159 | 159 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 160 | 160 | 63mm PVC Bend | 35 | Nos | |
| 161 | 161 | 63mm x 50mm PVC Threaded coupler | 12 | Nos | |
| 162 | 162 | 63mm x 50mm PVC Tee | 22 | Nos | |
| 163 | 163 | 63mm End cap | 32 | Nos | |
| 164 | 164 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 165 | 165 | a.50mm GI pipe | 56 | Rm | |
| 166 | 166 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 167 | 167 | a.50mm GI Elbow page 25 sl.no 1 | 8 | Nos | |
| 168 | 168 | b 50mm GI coupling page 25, sl.no 3 | 9 | Nos | |
| 169 | 169 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 170 | 170 | a.50 mm dia Pipe | 56 | Rm | |
| 171 | 171 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 172 | 172 | Water meter Dirt BOX | 1 | No | |
| 173 | 173 | Water meter erection charges | 1 | No | |
| 174 | 174 | Provision for pit for Dual line | 1 | No | |
| 175 | 175 | Distribution Line 75mm PVC Pipe | |||
| 176 | 176 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 198 | R.M | |
| 177 | 177 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 178 | 178 | 75 mm OD PVC Pipe 4 KSC | 198 | R.M | |
| 179 | 179 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 180 | 180 | 75 mm OD PVC Pipe 4 KSC | 198 | R.M | |
| 181 | 181 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 182 | 182 | 75 mm OD PVC Pipe 4 KSC | 198 | Rm | |
| 183 | 183 | Solvent Cement @ 0.75 Lit/100 m. | 1.485 | Lit. | |
| 184 | 184 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 185 | 185 | 75mm PVC Bend | 8 | Nos | |
| 186 | 186 | 75mm PVC coupler | 5 | Nos | |
| 187 | 187 | 75mm PVC Tee | 6 | Nos | |
| 188 | 188 | 75mm End cap | 4 | Nos | |
| 189 | 189 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 190 | 190 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 71 | Metre | |
| 191 | 191 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 71 | Nos. | |
| 192 | 192 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 71 | Nos. | |
| 193 | 193 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 71 | Nos. | |
| 194 | 194 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 71 | Nos. | |
| 195 | 195 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 196 | 196 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 8 | Metre | |
| 197 | 197 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 8 | Nos. | |
| 198 | 198 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 8 | Nos. | |
| 199 | 199 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 8 | Nos. | |
| 200 | 200 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 8 | Nos. | |
| 201 | 201 | NEW FHTC - 63 x 20mm | |||
| 202 | 202 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 71 | Nos. | |
| 203 | 203 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 71 | Nos. | |
| 204 | 204 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 71 | Nos. | |
| 205 | 205 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 213 | Nos. | |
| 206 | 206 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 568 | Rm | |
| 207 | 207 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 426 | Rm | |
| 208 | 208 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 568 | Rm | |
| 209 | 209 | Supply & Jointing 20 mm Waste Not tap | 71 | Nos. | |
| 210 | 210 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 71 | Nos. | |
| 211 | 211 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 71 | Nos. | |
| 212 | 212 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 284 | Nos. | |
| 213 | 213 | NEW FHTC - 75 x 20mm | |||
| 214 | 214 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 8 | Nos. | |
| 215 | 215 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 8 | Nos. | |
| 216 | 216 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 8 | Nos. | |
| 217 | 217 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 24 | Nos. | |
| 218 | 218 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 64 | Rm | |
| 219 | 219 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 48 | Rm | |
| 220 | 220 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 64 | Rm | |
| 221 | 221 | Supply & Jointing 20 mm Waste Not tap | 8 | Nos. | |
| 222 | 222 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 8 | Nos. | |
| 223 | 223 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 8 | Nos. | |
| 224 | 224 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 32 | Nos. | |
| 225 | 225 | Repairs to 10000 Litre OHT at Vanapuram AD colony | |||
| 226 | 226 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 14.27 | Sq.m | |
| 227 | 227 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 123.25 | Sq.m | |
| 228 | 228 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 229 | 229 | 50mm G.I Gate Valve | 2 | Nos | |
| 230 | 230 | 50mm G.I Gate Valve | 1 | Nos | |
| 231 | 231 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 232 | 232 | Repairs to 30000 Litre OHT at Vanapuram sannathi theru | |||
| 233 | 233 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 6.25 | Sq.m | |
| 234 | 234 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 8.64 | Sq.m | |
| 235 | 235 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.54 | Cu.m | |
| 236 | 236 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 157.25 | Sq.m | |
| 237 | 237 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 238 | 238 | Provision for RCC Inner Ladder | 1 | No | |
| 239 | 239 | Manhole cover 60 x 60 cm (heavy duty) with frame s.no.192(Building materials) TWAAD SOR. | 1 | No | |
| 240 | 240 | Provision for Ventilator | 1 | No | |
| 241 | 241 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 242 | 242 | To purchase of for 7.5 HP Submersible motor (50 x 125)7.5hp 3ph(88)(102)(62300)= 62300 | |||
| 243 | 243 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) | 1 | set | |
| 244 | 244 | Construction of Road for Restoring the Cut Portion. | |||
| 245 | 245 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 2.88 | Cu.m | |
| 246 | 246 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 1.92 | Cu.m | |
| 247 | 247 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 1.92 | Cu.m | |
| 248 | 248 | Provision for Name board | 1 | No | |
| 249 | 249 | Part.2.Providing Functional Household Tap Connections (FHTCs) and water supply works in Malaiyappanallur Panchayat. | |||
| 250 | 250 | 1. Malayappanallur Habitation | |||
| 251 | 251 | Distribution Line 63mm PVC Pipe | |||
| 252 | 252 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1770 | R.M | |
| 253 | 253 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 254 | 254 | 63 mm OD PVC Pipe 4 KSC | 1770 | R.M | |
| 255 | 255 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 256 | 256 | 63 mm OD PVC Pipe 4 KSC | 1770 | R.M | |
| 257 | 257 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 258 | 258 | 63 mm OD PVC Pipe 4 KSC | 1770 | R.M | |
| 259 | 259 | Solvent Cement @ 0.75 Lit/100 m. | 13.275 | Lit. | |
| 260 | 260 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 261 | 261 | 63mm PVC Bend | 48 | Nos | |
| 262 | 262 | 63mm x 50mm PVC Threaded coupler | 21 | Nos | |
| 263 | 263 | 63mm x 50mm PVC Tee | 18 | Nos | |
| 264 | 264 | 63mm End cap | 20 | Nos | |
| 265 | 265 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 266 | 266 | a.50mm GI pipe | 12 | Rm | |
| 267 | 267 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 268 | 268 | a.50mm GI Elbow page 25 sl.no 1 | 2 | Nos | |
| 269 | 269 | b 50mm GI coupling page 25, sl.no 3 | 2 | Nos | |
| 270 | 270 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 271 | 271 | a.50 mm dia Pipe | 12 | Rm | |
| 272 | 272 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 273 | 273 | Water meter Dirt BOX | 1 | No | |
| 274 | 274 | Water meter erection charges | 1 | No | |
| 275 | 275 | Provision for pit for Dual line | 1 | No | |
| 276 | 276 | Provision for 50mm Gate Valve | 2 | Nos | |
| 277 | 277 | Distribution Line 75mm PVC Pipe | |||
| 278 | 278 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 196 | R.M | |
| 279 | 279 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 280 | 280 | 75 mm OD PVC Pipe 4 KSC | 196 | R.M | |
| 281 | 281 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 282 | 282 | 75 mm OD PVC Pipe 4 KSC | 196 | R.M | |
| 283 | 283 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 284 | 284 | 75 mm OD PVC Pipe 4 KSC | 196 | Rm | |
| 285 | 285 | Solvent Cement @ 0.75 Lit/100 m. | 1.47 | Lit. | |
| 286 | 286 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 287 | 287 | 75mm PVC Bend | 2 | Nos | |
| 288 | 288 | 75mm PVC coupler | 4 | Nos | |
| 289 | 289 | 75mm PVC Tee | 2 | Nos | |
| 290 | 290 | 75mm End cap | 1 | Nos | |
| 291 | 291 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 292 | 292 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 56 | Metre | |
| 293 | 293 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 56 | Nos. | |
| 294 | 294 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 56 | Nos. | |
| 295 | 295 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 56 | Nos. | |
| 296 | 296 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 56 | Nos. | |
| 297 | 297 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 298 | 298 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 6 | Metre | |
| 299 | 299 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 6 | Nos. | |
| 300 | 300 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 6 | Nos. | |
| 301 | 301 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 6 | Nos. | |
| 302 | 302 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 6 | Nos. | |
| 303 | 303 | NEW FHTC - 63 x 20mm | |||
| 304 | 304 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 150 | Nos. | |
| 305 | 305 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 150 | Nos. | |
| 306 | 306 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 150 | Nos. | |
| 307 | 307 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 450 | Nos. | |
| 308 | 308 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 1200 | Rm | |
| 309 | 309 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 900 | Rm | |
| 310 | 310 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 1200 | Rm | |
| 311 | 311 | Supply & Jointing 20 mm Waste Not tap | 150 | Metre. | |
| 312 | 312 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 150 | Nos. | |
| 313 | 313 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 150 | Nos. | |
| 314 | 314 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 600 | Nos. | |
| 315 | 315 | NEW FHTC - 75 x 20mm | |||
| 316 | 316 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 16 | Nos. | |
| 317 | 317 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 16 | Nos. | |
| 318 | 318 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 16 | Nos. | |
| 319 | 319 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 48 | Nos. | |
| 320 | 320 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 128 | Rm | |
| 321 | 321 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 96 | Rm | |
| 322 | 322 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 128 | Rm | |
| 323 | 323 | Supply & Jointing 20 mm Waste Not tap | 16 | Nos. | |
| 324 | 324 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 16 | Nos. | |
| 325 | 325 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 16 | Nos. | |
| 326 | 326 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 64 | Nos. | |
| 327 | 327 | Repairs to 10000 Litre OHT at Malayappanallur | |||
| 328 | 328 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 10.72 | Sq.m | |
| 329 | 329 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 115.17 | Sq.m | |
| 330 | 330 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 331 | 331 | 80mm G.I Pipe | 30 | Rm | |
| 332 | 332 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 333 | 333 | Repairs to 10000 Litre OHT at Anna Nagar | |||
| 334 | 334 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 10.72 | Sq.m | |
| 335 | 335 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 115.17 | Sq.m | |
| 336 | 336 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 337 | 337 | 80mm G.I Pipe | 30 | Rm | |
| 338 | 338 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 339 | 339 | Repairs to 30000 Litre OHT at Malayappanallur | |||
| 340 | 340 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 12.76 | Sq.m | |
| 341 | 341 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 342 | 342 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 343 | 343 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 344 | 344 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 147.06 | Sq.m | |
| 345 | 345 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 346 | 346 | Provision for RCC Inner Ladder | 1 | Nos | |
| 347 | 347 | 65mm G.I Gate Valve | 2 | Nos | |
| 348 | 348 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 349 | 349 | Supply and delivery of 50mm GI Pipes. | 2 | Rm | |
| 350 | 350 | Construction of Road for Restoring the Cut Portion. | |||
| 351 | 351 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 2.16 | Cu.m | |
| 352 | 352 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 1.44 | Cu.m | |
| 353 | 353 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 1.44 | Cu.m | |
| 354 | 354 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977 | |||
| 355 | 355 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD) | 1 | set | |
| 356 | 356 | Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 101 | 1 | set | |
| 357 | 357 | Provision for Name board | 1 | No | |
| 358 | 358 | 2. Sivapuram Habitation | |||
| 359 | 359 | Distribution Line 63mm PVC Pipe | |||
| 360 | 360 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 2713 | R.M | |
| 361 | 361 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 362 | 362 | 63 mm OD PVC Pipe 4 KSC | 2713 | R.M | |
| 363 | 363 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 364 | 364 | 63 mm OD PVC Pipe 4 KSC | 2713 | R.M | |
| 365 | 365 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 366 | 366 | 63 mm OD PVC Pipe 4 KSC | 2713 | R.M | |
| 367 | 367 | Solvent Cement @ 0.75 Lit/100 m. | 20.348 | Lit. | |
| 368 | 368 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 369 | 369 | 63mm PVC Bend | 54 | Nos | |
| 370 | 370 | 63mm x 50mm PVC Threaded coupler | 32 | Nos | |
| 371 | 371 | 63mm x 50mm PVC Tee | 25 | Nos | |
| 372 | 372 | 63mm End cap | 24 | Nos | |
| 373 | 373 | Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking | |||
| 374 | 374 | a.50mm GI pipe | 9 | Rm | |
| 375 | 375 | Supply and delivery of GI specials to site of work as per IS specification with ISI marking | |||
| 376 | 376 | a.50mm GI Elbow page 25 sl.no 1 | 2 | Nos | |
| 377 | 377 | b 50mm GI coupling page 25, sl.no 3 | 2 | Nos | |
| 378 | 378 | Laying and jointing of GI Pipes with GI specials and PVC specials etc | |||
| 379 | 379 | a.50 mm dia Pipe | 9 | Rm | |
| 380 | 380 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 381 | 381 | Water meter Dirt BOX | 1 | No | |
| 382 | 382 | Water meter erection charges | 1 | No | |
| 383 | 383 | Provision for pit for Dual line | 1 | No | |
| 384 | 384 | Provision for 50mm Gate Valve | 2 | No | |
| 385 | 385 | Distribution Line 75mm PVC Pipe | |||
| 386 | 386 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 301 | R.M | |
| 387 | 387 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 388 | 388 | 75 mm OD PVC Pipe 4 KSC | 301 | R.M | |
| 389 | 389 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 390 | 390 | 75 mm OD PVC Pipe 4 KSC | 301 | R.M | |
| 391 | 391 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 392 | 392 | 75 mm OD PVC Pipe 4 KSC | 301 | Rm | |
| 393 | 393 | Solvent Cement @ 0.75 Lit/100 m. | 2.258 | Lit. | |
| 394 | 394 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 395 | 395 | 75mm PVC Bend | 4 | Nos | |
| 396 | 396 | 75mm PVC coupler | 6 | Nos | |
| 397 | 397 | 75mm PVC Tee | 2 | Nos | |
| 398 | 398 | 75mm End cap | 4 | Nos | |
| 399 | 399 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 400 | 400 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 89 | Metre | |
| 401 | 401 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 89 | Nos. | |
| 402 | 402 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 89 | Nos. | |
| 403 | 403 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 89 | Nos. | |
| 404 | 404 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 89 | Nos. | |
| 405 | 405 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 406 | 406 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 10 | Metre | |
| 407 | 407 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 10 | Nos. | |
| 408 | 408 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 10 | Nos. | |
| 409 | 409 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 10 | Nos. | |
| 410 | 410 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 10 | Nos. | |
| 411 | 411 | NEW FHTC - 63 x 20mm | |||
| 412 | 412 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 293 | Nos. | |
| 413 | 413 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 293 | Nos. | |
| 414 | 414 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 293 | Nos. | |
| 415 | 415 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 879 | Nos. | |
| 416 | 416 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 2344 | Rm | |
| 417 | 417 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 1758 | Rm | |
| 418 | 418 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 2344 | Rm | |
| 419 | 419 | Supply & Jointing 20 mm Waste Not tap | 293 | Nos. | |
| 420 | 420 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 293 | Nos. | |
| 421 | 421 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 293 | Nos. | |
| 422 | 422 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 1172 | Nos. | |
| 423 | 423 | NEW FHTC - 75 x 20mm | |||
| 424 | 424 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 32 | Nos. | |
| 425 | 425 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 32 | Nos. | |
| 426 | 426 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 32 | Nos. | |
| 427 | 427 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 96 | Nos. | |
| 428 | 428 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 256 | Rm | |
| 429 | 429 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 192 | Rm | |
| 430 | 430 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 256 | Rm | |
| 431 | 431 | Supply & Jointing 20 mm Waste Not tap | 32 | Nos. | |
| 432 | 432 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 32 | Nos. | |
| 433 | 433 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 32 | Nos. | |
| 434 | 434 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 128 | Nos. | |
| 435 | 435 | Repairs to 60000 Litre OHT at Madhakoil street | |||
| 436 | 436 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 24.6 | Sq.m | |
| 437 | 437 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 30.85 | Sq.m | |
| 438 | 438 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 439 | 439 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 440 | 440 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 132.75 | Sq.m | |
| 441 | 441 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 442 | 442 | Manhole cover 60 x 60 cm (heavy duty) with frame s.no.192(Building materials) TWAAD SOR. | 1 | nos | |
| 443 | 443 | 65mm G.I Gate Valve | 2 | Nos | |
| 444 | 444 | Air Compressor | 2 | Hour | |
| 445 | 445 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 20.41 | Sq.m | |
| 446 | 446 | Supply and delivery of 80mm GI Pipes. | 40 | Rm | |
| 447 | 447 | Repairs to 60000 Litre OHT at madhakoil street | |||
| 448 | 448 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 35.4 | Sq.m | |
| 449 | 449 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 143.77 | Sq.m | |
| 450 | 450 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 451 | 451 | 65mm G.I Coupling | 4 | Nos | |
| 452 | 452 | 65mm G.I pipe | 9 | Hour | |
| 453 | 453 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 20.41 | Sq.m | |
| 454 | 454 | Construction of Road for Restoring the Cut Portion. | |||
| 455 | 455 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 1.08 | Cu.m | |
| 456 | 456 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 0.72 | Cu.m | |
| 457 | 457 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 0.72 | Cu.m | |
| 458 | 458 | To purchase of for 7.5 HP Submersible motor (50 x 125)7.5hp 3ph(88)(102)(62300)= 62300 | |||
| 459 | 459 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) | 1 | Nos | |
| 460 | 460 | Provision for Name Board | 1 | Nos | |
| 461 | 461 | 3. Andakudaiyan Habitation | |||
| 462 | 462 | Distribution Line 63mm PVC Pipe | |||
| 463 | 463 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1520 | Nos | |
| 464 | 464 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 465 | 465 | 63 mm OD PVC Pipe 4 KSC | 1520 | Nos | |
| 466 | 466 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 467 | 467 | 63 mm OD PVC Pipe 4 KSC | 1520 | Nos | |
| 468 | 468 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 469 | 469 | 63 mm OD PVC Pipe 4 KSC | 1520 | Nos | |
| 470 | 470 | Solvent Cement @ 0.75 Lit/100 m. | 11.4 | Nos | |
| 471 | 471 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 472 | 472 | 63mm PVC Bend | 34 | Nos | |
| 473 | 473 | 63mm x 50mm PVC Threaded coupler | 28 | Nos | |
| 474 | 474 | 63mm x 50mm PVC Tee | 25 | Nos | |
| 475 | 475 | 63mm End cap | 26 | Nos | |
| 476 | 476 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 477 | 477 | Water meter Dirt BOX | 1 | No | |
| 478 | 478 | Water meter erection charges | 1 | No | |
| 479 | 479 | Provision for pit for Dual line | 1 | No | |
| 480 | 480 | Provision for 50mm Gate Valve | 2 | Nos | |
| 481 | 481 | Distribution Line 75mm PVC Pipe | |||
| 482 | 482 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 169 | R.M | |
| 483 | 483 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 484 | 484 | 75 mm OD PVC Pipe 4 KSC | 169 | R.M | |
| 485 | 485 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 486 | 486 | 75 mm OD PVC Pipe 4 KSC | 169 | R.M | |
| 487 | 487 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 488 | 488 | 75 mm OD PVC Pipe 4 KSC | 169 | Rm | |
| 489 | 489 | Solvent Cement @ 0.75 Lit/100 m. | 1.268 | Lit. | |
| 490 | 490 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 491 | 491 | 75mm PVC Bend | 2 | Nos | |
| 492 | 492 | 75mm PVC coupler | 4 | Nos | |
| 493 | 493 | 75mm PVC Tee | 2 | Nos | |
| 494 | 494 | 75mm End cap | 2 | Nos | |
| 495 | 495 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 496 | 496 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 37 | Metre | |
| 497 | 497 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 37 | Nos. | |
| 498 | 498 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 37 | Nos. | |
| 499 | 499 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 37 | Nos. | |
| 500 | 500 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 37 | Nos. | |
| 501 | 501 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 502 | 502 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 4 | Metre | |
| 503 | 503 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 4 | Nos. | |
| 504 | 504 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 4 | Nos. | |
| 505 | 505 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 4 | Nos. | |
| 506 | 506 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 4 | Nos. | |
| 507 | 507 | NEW FHTC - 63 x 20mm | |||
| 508 | 508 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 51 | Nos. | |
| 509 | 509 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 51 | Nos. | |
| 510 | 510 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 51 | Nos. | |
| 511 | 511 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 153 | Nos. | |
| 512 | 512 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 408 | Rm | |
| 513 | 513 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 306 | Rm | |
| 514 | 514 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 408 | Rm | |
| 515 | 515 | Supply & Jointing 20 mm Waste Not tap | 51 | Nos. | |
| 516 | 516 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 51 | Nos. | |
| 517 | 517 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 51 | Nos. | |
| 518 | 518 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 204 | Nos. | |
| 519 | 519 | NEW FHTC - 75 x 20mm | |||
| 520 | 520 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 6 | Nos. | |
| 521 | 521 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 6 | Nos. | |
| 522 | 522 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 6 | Nos. | |
| 523 | 523 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 18 | Nos. | |
| 524 | 524 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 48 | Rm | |
| 525 | 525 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 36 | Rm | |
| 526 | 526 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 48 | Rm | |
| 527 | 527 | Supply & Jointing 20 mm Waste Not tap | 6 | Nos. | |
| 528 | 528 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 6 | Nos. | |
| 529 | 529 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 6 | Nos. | |
| 530 | 530 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 24 | Nos. | |
| 531 | 531 | Repairs to 10000 Litre OHT Aalamaram | |||
| 532 | 532 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 10.72 | Sq.m | |
| 533 | 533 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 124.24 | Sq.m | |
| 534 | 534 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6 | Sq.m | |
| 535 | 535 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 536 | 536 | Supply and delivery of 50mm GI Pipes. | 30 | Rm | |
| 537 | 537 | Repairs to 30000 Litre OHT Andakudaiyan | |||
| 538 | 538 | Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete. | 12.76 | Sq.m | |
| 539 | 539 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 540 | 540 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 541 | 541 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 542 | 542 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 159.82 | Sq.m | |
| 543 | 543 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 544 | 544 | Provision for 65mm Gate valve | 2 | Nos | |
| 545 | 545 | Provision for AirCompressor | 2 | hours | |
| 546 | 546 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 547 | 547 | Supply and delivery of 50mm GI Pipes. | 14 | Rm | |
| 548 | 548 | Provision for 50mm GI coupling | 2 | Nos | |
| 549 | 549 | Construction of Road for Restoring the Cut Portion. | |||
| 550 | 550 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 1.44 | Cu.m | |
| 551 | 551 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 0.96 | Cu.m | |
| 552 | 552 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 0.96 | Cu.m | |
| 553 | 553 | Provision for Name Board | 1 | Nos | |
| 554 | 554 | Part.3.Providing Functional Household Tap Connections (FHTCs) and water supply works in Sinivasanallur Panchayat. | |||
| 555 | 555 | 1. Pangal Habitation | |||
| 556 | 556 | Distribution Line 63mm PVC Pipe | |||
| 557 | 557 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 1656 | R.M | |
| 558 | 558 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 559 | 559 | 63 mm OD PVC Pipe 4 KSC | 1656 | R.M | |
| 560 | 560 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 561 | 561 | 63 mm OD PVC Pipe 4 KSC | 1656 | R.M | |
| 562 | 562 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 563 | 563 | 63 mm OD PVC Pipe 4 KSC | 1656 | R.M | |
| 564 | 564 | Solvent Cement @ 0.75 Lit/100 m. | 12.42 | Lit. | |
| 565 | 565 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 566 | 566 | 63mm PVC Bend | 7 | Nos | |
| 567 | 567 | 63mm x 50mm PVC Threaded coupler | 27 | Nos | |
| 568 | 568 | 63mm x 50mm PVC Tee | 10 | Nos | |
| 569 | 569 | 63mm End cap | 12 | Nos | |
| 570 | 570 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 571 | 571 | Water meter Dirt BOX | 1 | No | |
| 572 | 572 | Water meter erection charges | 1 | No | |
| 573 | 573 | Provision for pit for Dual line | 1 | No | |
| 574 | 574 | Provision for 50mm Gate Valve | 2 | No | |
| 575 | 575 | Distribution Line 75mm PVC Pipe | |||
| 576 | 576 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 184 | R.M | |
| 577 | 577 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 578 | 578 | 75 mm OD PVC Pipe 4 KSC | 184 | R.M | |
| 579 | 579 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 580 | 580 | 75 mm OD PVC Pipe 4 KSC | 184 | R.M | |
| 581 | 581 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 582 | 582 | 75 mm OD PVC Pipe 4 KSC | 184 | Rm | |
| 583 | 583 | Solvent Cement @ 0.75 Lit/100 m. | 1.38 | Lit. | |
| 584 | 584 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 585 | 585 | 75mm PVC Bend | 2 | Nos | |
| 586 | 586 | 75mm PVC coupler | 3 | Nos | |
| 587 | 587 | 75mm PVC Tee | 3 | Nos | |
| 588 | 588 | 75mm End cap | 4 | Nos | |
| 589 | 589 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 590 | 590 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 36 | Metre | |
| 591 | 591 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 36 | Nos. | |
| 592 | 592 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 36 | Nos. | |
| 593 | 593 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 36 | Nos. | |
| 594 | 594 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 36 | Nos. | |
| 595 | 595 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 596 | 596 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 4 | Metre | |
| 597 | 597 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 4 | Nos. | |
| 598 | 598 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 4 | Nos. | |
| 599 | 599 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 4 | Nos. | |
| 600 | 600 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 4 | Nos. | |
| 601 | 601 | NEW FHTC - 63 x 20mm | |||
| 602 | 602 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 70 | Nos. | |
| 603 | 603 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 70 | Nos. | |
| 604 | 604 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 70 | Nos. | |
| 605 | 605 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 210 | Nos. | |
| 606 | 606 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 560 | Rm | |
| 607 | 607 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 420 | Rm | |
| 608 | 608 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 560 | Rm | |
| 609 | 609 | Supply & Jointing 20 mm Waste Not tap | 70 | Metre. | |
| 610 | 610 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 70 | Nos. | |
| 611 | 611 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 70 | Nos. | |
| 612 | 612 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 280 | Nos. | |
| 613 | 613 | NEW FHTC - 75 x 20mm | |||
| 614 | 614 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 8 | Nos. | |
| 615 | 615 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 8 | Nos. | |
| 616 | 616 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 8 | Nos. | |
| 617 | 617 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 24 | Nos. | |
| 618 | 618 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 64 | Rm | |
| 619 | 619 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 48 | Rm | |
| 620 | 620 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 64 | Rm | |
| 621 | 621 | Supply & Jointing 20 mm Waste Not tap | 8 | Nos. | |
| 622 | 622 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 8 | Nos. | |
| 623 | 623 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 8 | Nos. | |
| 624 | 624 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 32 | Nos. | |
| 625 | 625 | Repairs to 30000 Litre OHT Pangal | |||
| 626 | 626 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 627 | 627 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 628 | 628 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 629 | 629 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 157.72 | Sq.m | |
| 630 | 630 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 631 | 631 | Inner Ladder | |||
| 632 | 632 | RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete | 0.18 | Cu.m | |
| 633 | 633 | Supply, fabrication, placing in position of steel rods cutting tying etc.complete including cost of reinfor cement RTS rods | 40.53 | Kg | |
| 634 | 634 | Centering, for soffits of RCC works including strutting shuttering charges etc. complete | 3.24 | Sq.m | |
| 635 | 635 | Labour charges for lowering and fixing of RCC ladder inside the OHT | 1 | Nos | |
| 636 | 636 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 637 | 637 | 65mm Gate valve | 1 | Nos | |
| 638 | 638 | 65mm GI coupling | 1 | Nos | |
| 639 | 639 | Construction of Road for Restoring the Cut Portion. | |||
| 640 | 640 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 0.72 | Cu.m | |
| 641 | 641 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 0.48 | Cu.m | |
| 642 | 642 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 0.48 | Cu.m | |
| 643 | 643 | Provision for Name Board | 1 | Nos | |
| 644 | 644 | 2. Srinivasanallur Habitation | |||
| 645 | 645 | Distribution Line 63mm PVC Pipe | |||
| 646 | 646 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 3136 | Nos | |
| 647 | 647 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 648 | 648 | 63 mm OD PVC Pipe 4 KSC | 3136 | Nos | |
| 649 | 649 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 650 | 650 | 63 mm OD PVC Pipe 4 KSC | 3136 | Nos | |
| 651 | 651 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 652 | 652 | 63 mm OD PVC Pipe 4 KSC | 3136 | Nos | |
| 653 | 653 | Solvent Cement @ 0.75 Lit/100 m. | 23.52 | Nos | |
| 654 | 654 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 655 | 655 | 63mm PVC Bend | 10 | Nos | |
| 656 | 656 | 63mm x 50mm PVC Threaded coupler | 18 | Nos | |
| 657 | 657 | 63mm x 50mm PVC Tee | 15 | Nos | |
| 658 | 658 | 63mm End cap | 24 | Nos | |
| 659 | 659 | Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause | 1 | No | |
| 660 | 660 | Water meter Dirt BOX | 1 | No | |
| 661 | 661 | Water meter erection charges | 1 | No | |
| 662 | 662 | Provision for pit for Dual line | 1 | No | |
| 663 | 663 | Provision for 50mm Gate Valve | 2 | No | |
| 664 | 664 | Distribution Line 75mm PVC Pipe | |||
| 665 | 665 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 349 | R.M | |
| 666 | 666 | Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works | |||
| 667 | 667 | 75 mm OD PVC Pipe 4 KSC | 349 | R.M | |
| 668 | 668 | Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc | |||
| 669 | 669 | 75 mm OD PVC Pipe 4 KSC | 349 | R.M | |
| 670 | 670 | Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested. | |||
| 671 | 671 | 75 mm OD PVC Pipe 4 KSC | 349 | Rm | |
| 672 | 672 | Solvent Cement @ 0.75 Lit/100 m. | 2.618 | Lit. | |
| 673 | 673 | Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works | |||
| 674 | 674 | 75mm PVC Bend | 6 | Nos | |
| 675 | 675 | 75mm PVC coupler | 10 | Nos | |
| 676 | 676 | 75mm PVC Tee | 5 | Nos | |
| 677 | 677 | 75mm End cap | 6 | Nos | |
| 678 | 678 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm) | |||
| 679 | 679 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 139 | Metre | |
| 680 | 680 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 139 | Nos. | |
| 681 | 681 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 139 | Nos. | |
| 682 | 682 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 139 | Nos. | |
| 683 | 683 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 139 | Nos. | |
| 684 | 684 | Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm) | |||
| 685 | 685 | Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001 | 15 | Metre | |
| 686 | 686 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 15 | Nos. | |
| 687 | 687 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 15 | Nos. | |
| 688 | 688 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 15 | Nos. | |
| 689 | 689 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 15 | Nos. | |
| 690 | 690 | NEW FHTC - 63 x 20mm | |||
| 691 | 691 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 373 | Nos. | |
| 692 | 692 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 373 | Nos. | |
| 693 | 693 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 373 | Nos. | |
| 694 | 694 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 1119 | Nos. | |
| 695 | 695 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 2984 | Rm | |
| 696 | 696 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 2238 | Rm | |
| 697 | 697 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 2984 | Rm | |
| 698 | 698 | Supply & Jointing 20 mm Waste Not tap | 373 | Nos. | |
| 699 | 699 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 373 | Nos. | |
| 700 | 700 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 373 | Nos. | |
| 701 | 701 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 1492 | Nos. | |
| 702 | 702 | NEW FHTC - 75 x 20mm | |||
| 703 | 703 | HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11) | 42 | Nos. | |
| 704 | 704 | Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n | 42 | Nos. | |
| 705 | 705 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n | 42 | Nos. | |
| 706 | 706 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 126 | Nos. | |
| 707 | 707 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm | 336 | Rm | |
| 708 | 708 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) | 252 | Rm | |
| 709 | 709 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber | 336 | Rm | |
| 710 | 710 | Supply & Jointing 20 mm Waste Not tap | 42 | Nos. | |
| 711 | 711 | Labour charges for Drilling,Cutting and fixing flow control valve in distribution line | 42 | Nos. | |
| 712 | 712 | Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc | 42 | Nos. | |
| 713 | 713 | Cutting MDPE Pipes and specials true axis and finishing the end complete | 168 | Nos. | |
| 714 | 714 | Repairs to 10000 Litre OHT SathyaSai Nagar | |||
| 715 | 715 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 123.77 | Sq.m | |
| 716 | 716 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 717 | 717 | Manhole | |||
| 718 | 718 | Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg) | 5.4 | Kg | |
| 719 | 719 | centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75) | 0.225 | Sq.mt | |
| 720 | 720 | Supply and Fabrication placing posistion of Steel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg) | 2.184 | Kg | |
| 721 | 721 | Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075) | 0.042 | Cu.m | |
| 722 | 722 | Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete | 1 | Nos | |
| 723 | 723 | Ventilation | |||
| 724 | 724 | Supply and delivery of 50mm Gi pipe | 0.6 | Rm | |
| 725 | 725 | 50mm GI elbow | 2 | nos | |
| 726 | 726 | 50mm GI tee | 1 | Nos | |
| 727 | 727 | Cutting of 50mm GI pipe | 5 | Nos | |
| 728 | 728 | Threading of 50mm GI pipe | 5 | Nos | |
| 729 | 729 | supply of weld mesh with welding and fixing charges | 1 | Nos | |
| 730 | 730 | 50mm G.I Gate Valve | 2 | Nos | |
| 731 | 731 | 50mm G.I pipe | 2 | Rm | |
| 732 | 732 | 65mm G.I pipe | 2 | Rm | |
| 733 | 733 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 734 | 734 | Repairs to 10000 Litre OHT Thendral Nagar | |||
| 735 | 735 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 123.76 | Sq.m | |
| 736 | 736 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 737 | 737 | Manhole | |||
| 738 | 738 | Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg) | 5.4 | Kg | |
| 739 | 739 | centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75) | 0.225 | Sq.mt | |
| 740 | 740 | Supply and Fabrication placing posistion of Steel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg) | 2.184 | Kg | |
| 741 | 741 | Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075) | 0.042 | Cu.m | |
| 742 | 742 | Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete | 1 | Nos | |
| 743 | 743 | Ventilation | |||
| 744 | 744 | Supply and delivery of 50mm Gi pipe | 0.6 | Rm | |
| 745 | 745 | 50mm GI elbow | 2 | Nos | |
| 746 | 746 | 50mm GI tee | 1 | Nos | |
| 747 | 747 | Cutting of 50mm GI pipe | 5 | Nos | |
| 748 | 748 | Threading of 50mm GI pipe | 5 | Nos | |
| 749 | 749 | supply of weld mesh with welding and fixing charges | 1 | Nos | |
| 750 | 750 | 50mm G.I Gate Valve | 2 | Nos | |
| 751 | 751 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 12.87 | Sq.m | |
| 752 | 752 | Repairs to 30000 Litre OHT Sivankoil | |||
| 753 | 753 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 754 | 754 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 755 | 755 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 756 | 756 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 157.72 | Sq.m | |
| 757 | 757 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 758 | 758 | Inner Ladder | |||
| 759 | 759 | RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete | 0.18 | Cu.m | |
| 760 | 760 | Supply, fabrication, placing in position of steel rods cutting tying etc.complete including cost of reinfor cement RTS rods | 40.53 | Kg | |
| 761 | 761 | Centering, for soffits of RCC works including strutting shuttering charges etc. complete | 3.24 | Sq.m | |
| 762 | 762 | Labour charges for lowering and fixing of RCC ladder inside the OHT | 1 | Nos | |
| 763 | 763 | 65mm G.I Gate Valve | 1 | Nos | |
| 764 | 764 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 765 | 765 | 65mm G.I coupling | 1 | Nos | |
| 766 | 766 | 65mm G.I pipe | 6 | Rm | |
| 767 | 767 | Repairs to 30000 Litre OHT AnnaNagar | |||
| 768 | 768 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 20.74 | Sq.m | |
| 769 | 769 | Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers. | 10.8 | Sq.m | |
| 770 | 770 | Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers. | 0.68 | Cu.m | |
| 771 | 771 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 157.72 | Sq.m | |
| 772 | 772 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 773 | 773 | Inner Ladder | |||
| 774 | 774 | RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete | 0.18 | Cu.m | |
| 775 | 775 | Supply, fabrication, placing in position of steel rods cutting tying etc.complete including cost of reinfor cement RTS rods | 40.53 | Kg | |
| 776 | 776 | Centering, for soffits of RCC works including strutting shuttering charges etc. complete | 3.24 | Sq.m | |
| 777 | 777 | Labour charges for lowering and fixing of RCC ladder inside the OHT | 1 | Nos | |
| 778 | 778 | 65mm G.I Gate Valve | 1 | Nos | |
| 779 | 779 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 13.82 | Sq.m | |
| 780 | 780 | Repairs to 60000 Litre OHT Nagaraj Nagar | |||
| 781 | 781 | Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 35.4 | Sq.m | |
| 782 | 782 | Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification. | 145.32 | Sq.m | |
| 783 | 783 | Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete. | 6.93 | Sq.m | |
| 784 | 784 | Inner Ladder | |||
| 785 | 785 | RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete | 0.18 | Cu.m | |
| 786 | 786 | Supply, fabrication, placing in position of steel rods cutting tying etc.complete including cost of reinfor cement RTS rods | 40.53 | Kg | |
| 787 | 787 | Centering, for soffits of RCC works including strutting shuttering charges etc. complete | 3.24 | Sq.m | |
| 788 | 788 | Labour charges for lowering and fixing of RCC ladder inside the OHT | 1 | Nos | |
| 789 | 789 | Manhole | |||
| 790 | 790 | Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg) | 5.4 | Kg | |
| 791 | 791 | centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75) | 0.225 | Sq.mt | |
| 792 | 792 | Supply and Fabrication placing posistion of Steel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg) | 2.184 | Kg | |
| 793 | 793 | Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075) | 0.042 | Cu.m | |
| 794 | 794 | Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete | 1 | Nos | |
| 795 | 795 | Ventilation | |||
| 796 | 796 | Supply and delivery of 50mm Gi pipe | 0.6 | Rm | |
| 797 | 797 | 50mm GI elbow | 2 | Nos | |
| 798 | 798 | 50mm GI tee | 1 | Nos | |
| 799 | 799 | Cutting of 50mm GI pipe | 5 | Nos | |
| 800 | 800 | Threading of 50mm GI pipe | 5 | Nos | |
| 801 | 801 | supply of weld mesh with welding and fixing charges | 1 | Nos | |
| 802 | 802 | Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers. | 20.41 | Sq.m | |
| 803 | 803 | 65mm G.I coupling | 2 | Nos | |
| 804 | 804 | 65mm G.I pipe | 6 | Rm | |
| 805 | 805 | Construction of Road for Restoring the Cut Portion. | |||
| 806 | 806 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III. | 1.44 | Cu.m | |
| 807 | 807 | Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete. | 0.96 | Cu.m | |
| 808 | 808 | Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete. | 0.96 | Cu.m | |
| 809 | 809 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977 | |||
| 810 | 810 | To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD) | 1 | set | |
| 811 | 811 | Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 101 | 1 | set | |
| 812 | 812 | Provision for Name Board | 1 | No | |
| 813 | 813 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package}\n | 1 | GST Amount (in Rupees) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender