Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #25091321

Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In Govindapuram , Malaiyappanallur And Srinivasanallur Panchayats In Thiruvidaimarudur Block Of Thanjavur District-Year 2020-21 .

Issued by Local Bodies · Thiruvidaimarudur, Tamil Nadu
Tender Value
1.12 Crore
Estimated cost
Bid Submission
14 Aug 2020
0 days left
EMD
1.12 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvidaimarudur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Thanjavur District - Package No . 35 - Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In Govindapuram , Malaiyappanallur And Srinivasanallur Panchayats In Thiruvidaimarudur Block Of Thanjavur District-Year 2020-21 .

BOQ

Name of Work: THANJAVUR DISTRICT - JAL JEEVAN MISSION - 2020-2021. Part .1. Providing Functional Household Tap Connections (FHTCs) and water supply works in Govindapuram Panchayat., Part.2.Providing Functional Household Tap Connections (FHTCs) and water supply works in Malaiyappanallur Panchayat. Part.3.Providing Functional Household Tap Connections (FHTCs) and water supply works in Sinivasanallur Panchayat
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Part .1. Providing Functional Household Tap Connections (FHTCs) and water supply works in Govindapuram Panchayat.
221. Govindapuram Habitation
33Distribution Line 63mm PVC Pipe
44Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20015686R.M
55Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
6663 mm OD PVC Pipe 4 KSC5686R.M
77Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
8863 mm OD PVC Pipe 4 KSC5686R.M
99Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
101063 mm OD PVC Pipe 4 KSC5686R.M
1111Solvent Cement @ 0.75 Lit/100 m.42.65Lit.
1212Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
131363mm PVC Bend42Nos
141463mm x 50mm PVC Threaded coupler21Nos
151563mm x 50mm PVC Tee22Nos
161663mm End cap31Nos
1717Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
1818a.50mm GI pipe91Rm
1919Supply and delivery of GI specials to site of work as per IS specification with ISI marking
2020a.50mm GI Elbow page 25 sl.no 115Nos
2121b 50mm GI coupling page 25, sl.no 312Nos
2222Laying and jointing of GI Pipes with GI specials and PVC specials etc
2323a.50 mm dia Pipe91Rm
2424Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1No
2525Water meter Dirt BOX1No
2626Water meter erection charges1No
2727Provision for pit for Dual line1No
2828Distribution Line 75mm PVC Pipe
2929Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001632R.M
3030Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
313175 mm OD PVC Pipe 4 KSC632R.M
3232Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
333375 mm OD PVC Pipe 4 KSC632R.M
3434Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
353575 mm OD PVC Pipe 4 KSC632Rm
3636Solvent Cement @ 0.75 Lit/100 m.4.74Lit.
3737Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
383875mm PVC Bend12Nos
393975mm PVC coupler9Nos
404075mm PVC Tee8Nos
414175mm End cap4Nos
4242Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
4343Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001259Rm
4444Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n259Nos.
4545HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)259Nos.
4646Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n259Nos.
4747Labour charges for Drilling,Cutting and fixing flow control valve in distribution line259Nos.
4848Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
4949Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200129Cu.m
5050Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n29Nos.
5151HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)29Nos.
5252Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n29Nos.
5353Labour charges for Drilling,Cutting and fixing flow control valve in distribution line29Nos.
5454NEW FHTC - 63 x 20mm
5555HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)137Nos.
5656Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n137Nos.
5757Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n137Nos.
5858Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm411Nos.
5959MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm1096Rm
6060Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)822Rm
6161Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber1096Rm
6262Supply & Jointing 20 mm Waste Not tap137Metre.
6363Labour charges for Drilling,Cutting and fixing flow control valve in distribution line137Nos.
6464Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc137Nos.
6565Cutting MDPE Pipes and specials true axis and finishing the end complete548Nos.
6666NEW FHTC - 75 x 20mm
6767HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)15Nos.
6868Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n15Nos.
6969Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n15Nos.
7070Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm45Nos.
7171MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm120Rm
7272Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)90Rm
7373Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber120Rm
7474Supply & Jointing 20 mm Waste Not tap15Nos.
7575Labour charges for Drilling,Cutting and fixing flow control valve in distribution line15Nos.
7676Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc15Nos.
7777Cutting MDPE Pipes and specials true axis and finishing the end complete60Nos.
7878Repairs to 10000 Litre OHT at Govindapuram
7979Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.100.62Sq.m
8080Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
8181Gate Valve 50mm2Nos
8282Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
8383Repairs to 10000 Litre OHT at Govindapuram
8484Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.124.24Sq.m
8585Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
8686Gate Valve 50mm2Nos
8787Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
8888Repairs to 30000 Litre OHT at Govindapuram Muthaliyar Street
8989Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.66.3Sq.m
9090Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.159.82Sq.m
9191Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
9292Provision for RCC Inner Ladder1Nos
9393Gate Valve 50mm2Nos
9494Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
9595Repairs to 30000 Litre OHT at Govindapuram Mariyammankoil Street
9696Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.63.05Sq.m
9797Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.159.82Sq.m
9898Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
9999Provision for RCC Inner Ladder1Nos
100100Gate Valve 50mm2Nos
101101GI Pipe 50mm6Rm
102102Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
103103Repairs to 30000 Litre OHT at near Govindapuram Panchayat Office
104104Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.143.77Sq.m
105105Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
106106Provision for RCC Inner Ladder1Nos
107107Manhole cover 60 x 60 cm (heavy duty) with frame s.no.192(Building materials) TWAAD SOR.1Nos
108108Gate Valve 80mm2Nos
109109Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.20.41Sq.m
110110Provision for OHT Borewell
111111Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit.
1121120m to 60m depth60Rm
113113Reaming of 150mm Dia Borewell to 300mm Dia Borewell as directed at site
1141140m to 60m depth60Rm
115115Labour charges for inserting casing pipe supply & packing of pebbles60Rm
116116Supply & delivery of 150mm Dia PVC Plain Casing pipe as per IS 12818 / 201045Nos
117117Supply & delivery of 150mm Dia PVC Slotted Casing pipe as per IS 12818 / 201015Nos
118118Charges for developing the borewell using air compressor in hours8Hours
119119Pump Room
120120Earth work excavation & depositing on bank with an initial lead of 10 metre & initial lift of 2 metre in Hard shift clay, stiff block cotton, hard red earth shales, murrum, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil (SS 20B) for foundation including shoring, strutting, baling out water providing danger light wherever necessary depositing the surplus earth on bank and other incedential charges etc., complete and as directed by TWAD board Officers12.98Cu.m
121121Levelling course with P.C.C 1:4:8 (one cement, four sand and eigth course aggregate) using 40 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the Departmental Officers.2.56Cu.m
122122Earth filling in basement & sides of foundation with excavated earth including ramming and consolidation etc., complete5.78Cu.m
123123Supply and filling the foundation and basement with clear river sand in layers complying with standard specification including consolidation and watering etc. complete and as directed by Departmental Officers.1.86Cu.m
124124Brick work in CM 1:5 (one cement and five sand) using country bricks of size 8.75\" X 4.25\" X 2.00\" including cost of all materials, labour charges, curing etc., complete and as directed by Departmental Officers.
125125For foundation and basement8.46Cu.m
126126For super structure6.78Cu.m
127127Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.1.16Cu.m
128128Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) excluding cost of steel fabrication,fixing in position and centring charges but including mixing,lifting and vibrating for SUNSHADE 75mm thick at wall face and 50mm thick at free end projecting 45cm from wall face moulded along with lintel etc. as directed by Departmental Officers.2.4Cu.m
129129Steel centering for soffits of RCC members including shuttering,strutting to the centring and providing supports etc.complete for the following members using MS Sheets of size 90cm x 60cm and BG 10 Gaugesstiffened with welded MS angles of size 25 x 25 x3mm laid over Silver Oak(country wood) joists of size 10 x 6.5 cm (spaced at about 90cm C/C) and supported by Casurania props of 10 cm to 13 cm dia. spaced at 75 cm C/C and as directed by Departmental Officers.The centring materials should be supplied and should be removed after the specified stripping time of the concrete as per IS 456/1978.10.62Sq.m
130130Plastering with C.M. 1:5(One part of cement and Five parts of sand) with 12mm thick over brickwork portion including labour charges for mixing finishing and curing etc., complete and as directed by Departmental Officers.77Sq.m
131131Special ceiling plastering for RCC Slab with C.M.1:3(One part of cement and Three parts of sand) 10mm thickover RCC surface including labour charges for mixing finishingand curing etc., complete as directed by Departmental Officers.9.84Sq.m
132132Flooring in C C 1:4:8 (one cement ,four sand and eight HBS) 10 cm thick using 40mm HBS metal and top finished with Cement mortar 1:3 (one cement and three sand) 12 mm thick including labour charges for mixing,finishing and curing etc. complete and as directed by Departmental Officers.3.86Sq.m
133133Supply and fixing of MS door (Single leaf) of sizes 1.00 x 2.00m in MS angle 50 x 50 x 4mm and MS flat 35 x 6mm with MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locing arrangements including two coats of approved enamel painting over one coat of primer2No.
134134Supply, fabricating and fixing in position of RTS rods including cost of steel and binding wire etc., complete.0.82Qtl.
135135Supply and fixing of RCC box type jolly of size 0.6 x 0.45 m2Nos
136136Painting two coats with approved cement paint over one priming coat of white cement over cement plastered wall surface and ceiling including cleaning preparing the surface and curing etc., complete (using cement paint of colour as approved by the Departm77.32Sq.m
137137White washing two coats using fine screened shell lime for the new plastered surface for inner and outer side of the room including the cost of materials labour charges etc., complete and as directed by Departmental Officers.9.04Sq.m
138138Weathering Coarse over RCC roof including fixing one coarse of pressed tiles etc., complete.11.14Sq.m
139139Provision for writing TWAD Board emblem and scheme details on the side wall of the pump room2Sq.m
140140Provision of lock and key for pump room and OHT ladder4Nos
141141To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977
142142To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD)1set
143143Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 1011set
144144Construction of Road for Restoring the Cut Portion.
145145Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.4.68Cu.m
146146Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.3.12Cu.m
147147Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.3.12Cu.m
148148Provision for Name Board1Nos
1491492. Vanapuram Habitation
150150Distribution Line 63mm PVC Pipe
151151Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20011785R.M
152152Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
15315363 mm OD PVC Pipe 4 KSC1785R.M
154154Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
15515563 mm OD PVC Pipe 4 KSC1785R.M
156156Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
15715763 mm OD PVC Pipe 4 KSC1785R.M
158158Solvent Cement @ 0.75 Lit/100 m.13.388Lit.
159159Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
16016063mm PVC Bend35Nos
16116163mm x 50mm PVC Threaded coupler12Nos
16216263mm x 50mm PVC Tee22Nos
16316363mm End cap32Nos
164164Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
165165a.50mm GI pipe56Rm
166166Supply and delivery of GI specials to site of work as per IS specification with ISI marking
167167a.50mm GI Elbow page 25 sl.no 18Nos
168168b 50mm GI coupling page 25, sl.no 39Nos
169169Laying and jointing of GI Pipes with GI specials and PVC specials etc
170170a.50 mm dia Pipe56Rm
171171Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1No
172172Water meter Dirt BOX1No
173173Water meter erection charges1No
174174Provision for pit for Dual line1No
175175Distribution Line 75mm PVC Pipe
176176Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001198R.M
177177Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
17817875 mm OD PVC Pipe 4 KSC198R.M
179179Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
18018075 mm OD PVC Pipe 4 KSC198R.M
181181Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
18218275 mm OD PVC Pipe 4 KSC198Rm
183183Solvent Cement @ 0.75 Lit/100 m.1.485Lit.
184184Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
18518575mm PVC Bend8Nos
18618675mm PVC coupler5Nos
18718775mm PVC Tee6Nos
18818875mm End cap4Nos
189189Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
190190Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200171Metre
191191Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n71Nos.
192192HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)71Nos.
193193Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n71Nos.
194194Labour charges for Drilling,Cutting and fixing flow control valve in distribution line71Nos.
195195Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
196196Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20018Metre
197197Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n8Nos.
198198HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)8Nos.
199199Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n8Nos.
200200Labour charges for Drilling,Cutting and fixing flow control valve in distribution line8Nos.
201201NEW FHTC - 63 x 20mm
202202HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)71Nos.
203203Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n71Nos.
204204Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n71Nos.
205205Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm213Nos.
206206MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm568Rm
207207Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)426Rm
208208Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber568Rm
209209Supply & Jointing 20 mm Waste Not tap71Nos.
210210Labour charges for Drilling,Cutting and fixing flow control valve in distribution line71Nos.
211211Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc71Nos.
212212Cutting MDPE Pipes and specials true axis and finishing the end complete284Nos.
213213NEW FHTC - 75 x 20mm
214214HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)8Nos.
215215Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n8Nos.
216216Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n8Nos.
217217Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm24Nos.
218218MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm64Rm
219219Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)48Rm
220220Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber64Rm
221221Supply & Jointing 20 mm Waste Not tap8Nos.
222222Labour charges for Drilling,Cutting and fixing flow control valve in distribution line8Nos.
223223Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc8Nos.
224224Cutting MDPE Pipes and specials true axis and finishing the end complete32Nos.
225225Repairs to 10000 Litre OHT at Vanapuram AD colony
226226Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.14.27Sq.m
227227Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.123.25Sq.m
228228Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
22922950mm G.I Gate Valve2Nos
23023050mm G.I Gate Valve1Nos
231231Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
232232Repairs to 30000 Litre OHT at Vanapuram sannathi theru
233233Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.6.25Sq.m
234234Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.8.64Sq.m
235235Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.54Cu.m
236236Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.157.25Sq.m
237237Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
238238Provision for RCC Inner Ladder1No
239239Manhole cover 60 x 60 cm (heavy duty) with frame s.no.192(Building materials) TWAAD SOR.1No
240240Provision for Ventilator1No
241241Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
242242To purchase of for 7.5 HP Submersible motor (50 x 125)7.5hp 3ph(88)(102)(62300)= 62300
243243To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)1set
244244Construction of Road for Restoring the Cut Portion.
245245Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.2.88Cu.m
246246Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.1.92Cu.m
247247Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.1.92Cu.m
248248Provision for Name board1No
249249Part.2.Providing Functional Household Tap Connections (FHTCs) and water supply works in Malaiyappanallur Panchayat.
2502501. Malayappanallur Habitation
251251Distribution Line 63mm PVC Pipe
252252Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20011770R.M
253253Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
25425463 mm OD PVC Pipe 4 KSC1770R.M
255255Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
25625663 mm OD PVC Pipe 4 KSC1770R.M
257257Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
25825863 mm OD PVC Pipe 4 KSC1770R.M
259259Solvent Cement @ 0.75 Lit/100 m.13.275Lit.
260260Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
26126163mm PVC Bend48Nos
26226263mm x 50mm PVC Threaded coupler21Nos
26326363mm x 50mm PVC Tee18Nos
26426463mm End cap20Nos
265265Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
266266a.50mm GI pipe12Rm
267267Supply and delivery of GI specials to site of work as per IS specification with ISI marking
268268a.50mm GI Elbow page 25 sl.no 12Nos
269269b 50mm GI coupling page 25, sl.no 32Nos
270270Laying and jointing of GI Pipes with GI specials and PVC specials etc
271271a.50 mm dia Pipe12Rm
272272Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1No
273273Water meter Dirt BOX1No
274274Water meter erection charges1No
275275Provision for pit for Dual line1No
276276Provision for 50mm Gate Valve2Nos
277277Distribution Line 75mm PVC Pipe
278278Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001196R.M
279279Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
28028075 mm OD PVC Pipe 4 KSC196R.M
281281Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
28228275 mm OD PVC Pipe 4 KSC196R.M
283283Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
28428475 mm OD PVC Pipe 4 KSC196Rm
285285Solvent Cement @ 0.75 Lit/100 m.1.47Lit.
286286Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
28728775mm PVC Bend2Nos
28828875mm PVC coupler4Nos
28928975mm PVC Tee2Nos
29029075mm End cap1Nos
291291Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
292292Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200156Metre
293293Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n56Nos.
294294HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)56Nos.
295295Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n56Nos.
296296Labour charges for Drilling,Cutting and fixing flow control valve in distribution line56Nos.
297297Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
298298Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20016Metre
299299Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n6Nos.
300300HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)6Nos.
301301Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n6Nos.
302302Labour charges for Drilling,Cutting and fixing flow control valve in distribution line6Nos.
303303NEW FHTC - 63 x 20mm
304304HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)150Nos.
305305Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n150Nos.
306306Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n150Nos.
307307Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm450Nos.
308308MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm1200Rm
309309Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)900Rm
310310Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber1200Rm
311311Supply & Jointing 20 mm Waste Not tap150Metre.
312312Labour charges for Drilling,Cutting and fixing flow control valve in distribution line150Nos.
313313Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc150Nos.
314314Cutting MDPE Pipes and specials true axis and finishing the end complete600Nos.
315315NEW FHTC - 75 x 20mm
316316HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)16Nos.
317317Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n16Nos.
318318Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n16Nos.
319319Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm48Nos.
320320MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm128Rm
321321Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)96Rm
322322Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber128Rm
323323Supply & Jointing 20 mm Waste Not tap16Nos.
324324Labour charges for Drilling,Cutting and fixing flow control valve in distribution line16Nos.
325325Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc16Nos.
326326Cutting MDPE Pipes and specials true axis and finishing the end complete64Nos.
327327Repairs to 10000 Litre OHT at Malayappanallur
328328Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.10.72Sq.m
329329Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.115.17Sq.m
330330Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6Sq.m
33133180mm G.I Pipe30Rm
332332Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
333333Repairs to 10000 Litre OHT at Anna Nagar
334334Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.10.72Sq.m
335335Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.115.17Sq.m
336336Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6Sq.m
33733780mm G.I Pipe30Rm
338338Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
339339Repairs to 30000 Litre OHT at Malayappanallur
340340Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.12.76Sq.m
341341Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.20.74Sq.m
342342Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
343343Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
344344Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.147.06Sq.m
345345Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6Sq.m
346346Provision for RCC Inner Ladder1Nos
34734765mm G.I Gate Valve2Nos
348348Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
349349Supply and delivery of 50mm GI Pipes.2Rm
350350Construction of Road for Restoring the Cut Portion.
351351Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.2.16Cu.m
352352Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.1.44Cu.m
353353Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.1.44Cu.m
354354To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977
355355To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD)1set
356356Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 1011set
357357Provision for Name board1No
3583582. Sivapuram Habitation
359359Distribution Line 63mm PVC Pipe
360360Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20012713R.M
361361Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
36236263 mm OD PVC Pipe 4 KSC2713R.M
363363Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
36436463 mm OD PVC Pipe 4 KSC2713R.M
365365Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
36636663 mm OD PVC Pipe 4 KSC2713R.M
367367Solvent Cement @ 0.75 Lit/100 m.20.348Lit.
368368Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
36936963mm PVC Bend54Nos
37037063mm x 50mm PVC Threaded coupler32Nos
37137163mm x 50mm PVC Tee25Nos
37237263mm End cap24Nos
373373Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
374374a.50mm GI pipe9Rm
375375Supply and delivery of GI specials to site of work as per IS specification with ISI marking
376376a.50mm GI Elbow page 25 sl.no 12Nos
377377b 50mm GI coupling page 25, sl.no 32Nos
378378Laying and jointing of GI Pipes with GI specials and PVC specials etc
379379a.50 mm dia Pipe9Rm
380380Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1No
381381Water meter Dirt BOX1No
382382Water meter erection charges1No
383383Provision for pit for Dual line1No
384384Provision for 50mm Gate Valve2No
385385Distribution Line 75mm PVC Pipe
386386Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001301R.M
387387Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
38838875 mm OD PVC Pipe 4 KSC301R.M
389389Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
39039075 mm OD PVC Pipe 4 KSC301R.M
391391Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
39239275 mm OD PVC Pipe 4 KSC301Rm
393393Solvent Cement @ 0.75 Lit/100 m.2.258Lit.
394394Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
39539575mm PVC Bend4Nos
39639675mm PVC coupler6Nos
39739775mm PVC Tee2Nos
39839875mm End cap4Nos
399399Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
400400Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200189Metre
401401Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n89Nos.
402402HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)89Nos.
403403Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n89Nos.
404404Labour charges for Drilling,Cutting and fixing flow control valve in distribution line89Nos.
405405Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
406406Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200110Metre
407407Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n10Nos.
408408HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)10Nos.
409409Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n10Nos.
410410Labour charges for Drilling,Cutting and fixing flow control valve in distribution line10Nos.
411411NEW FHTC - 63 x 20mm
412412HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)293Nos.
413413Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n293Nos.
414414Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n293Nos.
415415Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm879Nos.
416416MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm2344Rm
417417Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)1758Rm
418418Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber2344Rm
419419Supply & Jointing 20 mm Waste Not tap293Nos.
420420Labour charges for Drilling,Cutting and fixing flow control valve in distribution line293Nos.
421421Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc293Nos.
422422Cutting MDPE Pipes and specials true axis and finishing the end complete1172Nos.
423423NEW FHTC - 75 x 20mm
424424HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)32Nos.
425425Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n32Nos.
426426Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n32Nos.
427427Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm96Nos.
428428MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm256Rm
429429Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)192Rm
430430Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber256Rm
431431Supply & Jointing 20 mm Waste Not tap32Nos.
432432Labour charges for Drilling,Cutting and fixing flow control valve in distribution line32Nos.
433433Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc32Nos.
434434Cutting MDPE Pipes and specials true axis and finishing the end complete128Nos.
435435Repairs to 60000 Litre OHT at Madhakoil street
436436Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.24.6Sq.m
437437Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.30.85Sq.m
438438Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
439439Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
440440Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.132.75Sq.m
441441Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6Sq.m
442442Manhole cover 60 x 60 cm (heavy duty) with frame s.no.192(Building materials) TWAAD SOR.1nos
44344365mm G.I Gate Valve2Nos
444444Air Compressor2Hour
445445Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.20.41Sq.m
446446Supply and delivery of 80mm GI Pipes.40Rm
447447Repairs to 60000 Litre OHT at madhakoil street
448448Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.35.4Sq.m
449449Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.143.77Sq.m
450450Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
45145165mm G.I Coupling4Nos
45245265mm G.I pipe9Hour
453453Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.20.41Sq.m
454454Construction of Road for Restoring the Cut Portion.
455455Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.1.08Cu.m
456456Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.0.72Cu.m
457457Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.0.72Cu.m
458458To purchase of for 7.5 HP Submersible motor (50 x 125)7.5hp 3ph(88)(102)(62300)= 62300
459459To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)1Nos
460460Provision for Name Board1Nos
4614613. Andakudaiyan Habitation
462462Distribution Line 63mm PVC Pipe
463463Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20011520Nos
464464Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
46546563 mm OD PVC Pipe 4 KSC1520Nos
466466Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
46746763 mm OD PVC Pipe 4 KSC1520Nos
468468Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
46946963 mm OD PVC Pipe 4 KSC1520Nos
470470Solvent Cement @ 0.75 Lit/100 m.11.4Nos
471471Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
47247263mm PVC Bend34Nos
47347363mm x 50mm PVC Threaded coupler28Nos
47447463mm x 50mm PVC Tee25Nos
47547563mm End cap26Nos
476476Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1No
477477Water meter Dirt BOX1No
478478Water meter erection charges1No
479479Provision for pit for Dual line1No
480480Provision for 50mm Gate Valve2Nos
481481Distribution Line 75mm PVC Pipe
482482Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001169R.M
483483Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
48448475 mm OD PVC Pipe 4 KSC169R.M
485485Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
48648675 mm OD PVC Pipe 4 KSC169R.M
487487Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
48848875 mm OD PVC Pipe 4 KSC169Rm
489489Solvent Cement @ 0.75 Lit/100 m.1.268Lit.
490490Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
49149175mm PVC Bend2Nos
49249275mm PVC coupler4Nos
49349375mm PVC Tee2Nos
49449475mm End cap2Nos
495495Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
496496Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200137Metre
497497Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n37Nos.
498498HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)37Nos.
499499Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n37Nos.
500500Labour charges for Drilling,Cutting and fixing flow control valve in distribution line37Nos.
501501Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
502502Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20014Metre
503503Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n4Nos.
504504HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)4Nos.
505505Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n4Nos.
506506Labour charges for Drilling,Cutting and fixing flow control valve in distribution line4Nos.
507507NEW FHTC - 63 x 20mm
508508HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)51Nos.
509509Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n51Nos.
510510Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n51Nos.
511511Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm153Nos.
512512MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm408Rm
513513Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)306Rm
514514Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber408Rm
515515Supply & Jointing 20 mm Waste Not tap51Nos.
516516Labour charges for Drilling,Cutting and fixing flow control valve in distribution line51Nos.
517517Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc51Nos.
518518Cutting MDPE Pipes and specials true axis and finishing the end complete204Nos.
519519NEW FHTC - 75 x 20mm
520520HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)6Nos.
521521Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n6Nos.
522522Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n6Nos.
523523Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm18Nos.
524524MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm48Rm
525525Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)36Rm
526526Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber48Rm
527527Supply & Jointing 20 mm Waste Not tap6Nos.
528528Labour charges for Drilling,Cutting and fixing flow control valve in distribution line6Nos.
529529Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc6Nos.
530530Cutting MDPE Pipes and specials true axis and finishing the end complete24Nos.
531531Repairs to 10000 Litre OHT Aalamaram
532532Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.10.72Sq.m
533533Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.124.24Sq.m
534534Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6Sq.m
535535Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
536536Supply and delivery of 50mm GI Pipes.30Rm
537537Repairs to 30000 Litre OHT Andakudaiyan
538538Dismantling existing damaged Plastering including Dismantling and remove in the depries and all labour charges etc., complete.12.76Sq.m
539539Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.20.74Sq.m
540540Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
541541Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
542542Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.159.82Sq.m
543543Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
544544Provision for 65mm Gate valve2Nos
545545Provision for AirCompressor2hours
546546Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
547547Supply and delivery of 50mm GI Pipes.14Rm
548548Provision for 50mm GI coupling2Nos
549549Construction of Road for Restoring the Cut Portion.
550550Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.1.44Cu.m
551551Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.0.96Cu.m
552552Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.0.96Cu.m
553553Provision for Name Board1Nos
554554Part.3.Providing Functional Household Tap Connections (FHTCs) and water supply works in Sinivasanallur Panchayat.
5555551. Pangal Habitation
556556Distribution Line 63mm PVC Pipe
557557Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20011656R.M
558558Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
55955963 mm OD PVC Pipe 4 KSC1656R.M
560560Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
56156163 mm OD PVC Pipe 4 KSC1656R.M
562562Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
56356363 mm OD PVC Pipe 4 KSC1656R.M
564564Solvent Cement @ 0.75 Lit/100 m.12.42Lit.
565565Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
56656663mm PVC Bend7Nos
56756763mm x 50mm PVC Threaded coupler27Nos
56856863mm x 50mm PVC Tee10Nos
56956963mm End cap12Nos
570570Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1No
571571Water meter Dirt BOX1No
572572Water meter erection charges1No
573573Provision for pit for Dual line1No
574574Provision for 50mm Gate Valve2No
575575Distribution Line 75mm PVC Pipe
576576Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001184R.M
577577Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
57857875 mm OD PVC Pipe 4 KSC184R.M
579579Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
58058075 mm OD PVC Pipe 4 KSC184R.M
581581Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
58258275 mm OD PVC Pipe 4 KSC184Rm
583583Solvent Cement @ 0.75 Lit/100 m.1.38Lit.
584584Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
58558575mm PVC Bend2Nos
58658675mm PVC coupler3Nos
58758775mm PVC Tee3Nos
58858875mm End cap4Nos
589589Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
590590Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200136Metre
591591Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n36Nos.
592592HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)36Nos.
593593Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n36Nos.
594594Labour charges for Drilling,Cutting and fixing flow control valve in distribution line36Nos.
595595Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
596596Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20014Metre
597597Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n4Nos.
598598HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)4Nos.
599599Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n4Nos.
600600Labour charges for Drilling,Cutting and fixing flow control valve in distribution line4Nos.
601601NEW FHTC - 63 x 20mm
602602HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)70Nos.
603603Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n70Nos.
604604Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n70Nos.
605605Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm210Nos.
606606MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm560Rm
607607Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)420Rm
608608Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber560Rm
609609Supply & Jointing 20 mm Waste Not tap70Metre.
610610Labour charges for Drilling,Cutting and fixing flow control valve in distribution line70Nos.
611611Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc70Nos.
612612Cutting MDPE Pipes and specials true axis and finishing the end complete280Nos.
613613NEW FHTC - 75 x 20mm
614614HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)8Nos.
615615Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n8Nos.
616616Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n8Nos.
617617Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm24Nos.
618618MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm64Rm
619619Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)48Rm
620620Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber64Rm
621621Supply & Jointing 20 mm Waste Not tap8Nos.
622622Labour charges for Drilling,Cutting and fixing flow control valve in distribution line8Nos.
623623Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc8Nos.
624624Cutting MDPE Pipes and specials true axis and finishing the end complete32Nos.
625625Repairs to 30000 Litre OHT Pangal
626626Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.20.74Sq.m
627627Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
628628Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
629629Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.157.72Sq.m
630630Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
631631Inner Ladder
632632RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
633633Supply, fabrication, placing in position of steel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
634634Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
635635Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
636636Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
63763765mm Gate valve1Nos
63863865mm GI coupling1Nos
639639Construction of Road for Restoring the Cut Portion.
640640Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.0.72Cu.m
641641Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.0.48Cu.m
642642Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.0.48Cu.m
643643Provision for Name Board1Nos
6446442. Srinivasanallur Habitation
645645Distribution Line 63mm PVC Pipe
646646Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.20013136Nos
647647Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
64864863 mm OD PVC Pipe 4 KSC3136Nos
649649Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
65065063 mm OD PVC Pipe 4 KSC3136Nos
651651Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
65265263 mm OD PVC Pipe 4 KSC3136Nos
653653Solvent Cement @ 0.75 Lit/100 m.23.52Nos
654654Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
65565563mm PVC Bend10Nos
65665663mm x 50mm PVC Threaded coupler18Nos
65765763mm x 50mm PVC Tee15Nos
65865863mm End cap24Nos
659659Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause1No
660660Water meter Dirt BOX1No
661661Water meter erection charges1No
662662Provision for pit for Dual line1No
663663Provision for 50mm Gate Valve2No
664664Distribution Line 75mm PVC Pipe
665665Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001349R.M
666666Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
66766775 mm OD PVC Pipe 4 KSC349R.M
668668Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
66966975 mm OD PVC Pipe 4 KSC349R.M
670670Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
67167175 mm OD PVC Pipe 4 KSC349Rm
672672Solvent Cement @ 0.75 Lit/100 m.2.618Lit.
673673Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
67467475mm PVC Bend6Nos
67567575mm PVC coupler10Nos
67667675mm PVC Tee5Nos
67767775mm End cap6Nos
678678Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(63 x 20mm)
679679Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001139Metre
680680Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n139Nos.
681681HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)139Nos.
682682Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n139Nos.
683683Labour charges for Drilling,Cutting and fixing flow control valve in distribution line139Nos.
684684Providing Flow control valve to Existing Authorised & under regularaisation FHTC. \n(75 x 20mm)
685685Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.200115Metre
686686Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n15Nos.
687687HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)15Nos.
688688Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n15Nos.
689689Labour charges for Drilling,Cutting and fixing flow control valve in distribution line15Nos.
690690NEW FHTC - 63 x 20mm
691691HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 63 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)373Nos.
692692Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n373Nos.
693693Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n373Nos.
694694Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm1119Nos.
695695MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm2984Rm
696696Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)2238Rm
697697Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber2984Rm
698698Supply & Jointing 20 mm Waste Not tap373Nos.
699699Labour charges for Drilling,Cutting and fixing flow control valve in distribution line373Nos.
700700Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc373Nos.
701701Cutting MDPE Pipes and specials true axis and finishing the end complete1492Nos.
702702NEW FHTC - 75 x 20mm
703703HSC Connection in DI Mains for Water Supply Scheme - Providing PVC saddle piece of size 75 x 20mm as per IS 7834/1987 (TWAD SOR Page no 11)42Nos.
704704Supply and delivery of Stainless steel Flow Control Valve having Stainless steel 202 grade body and Stainless steel ball in 304 grade. The Flow Control Valve shall have external threading and including packing, forwarding and transportation and as directed by the departmental officials.\n20mm size Flow control valve with an average flow rate of 10 – 15 lpm.\n42Nos.
705705Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)\n42Nos.
706706Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm126Nos.
707707MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm336Rm
708708Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)252Rm
709709Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber336Rm
710710Supply & Jointing 20 mm Waste Not tap42Nos.
711711Labour charges for Drilling,Cutting and fixing flow control valve in distribution line42Nos.
712712Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc42Nos.
713713Cutting MDPE Pipes and specials true axis and finishing the end complete168Nos.
714714Repairs to 10000 Litre OHT SathyaSai Nagar
715715Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.123.77Sq.m
716716Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
717717Manhole
718718Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
719719centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
720720Supply and Fabrication placing posistion of Steel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
721721Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
722722Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
723723Ventilation
724724Supply and delivery of 50mm Gi pipe0.6Rm
72572550mm GI elbow2nos
72672650mm GI tee1Nos
727727Cutting of 50mm GI pipe5Nos
728728Threading of 50mm GI pipe5Nos
729729supply of weld mesh with welding and fixing charges1Nos
73073050mm G.I Gate Valve2Nos
73173150mm G.I pipe2Rm
73273265mm G.I pipe2Rm
733733Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
734734Repairs to 10000 Litre OHT Thendral Nagar
735735Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.123.76Sq.m
736736Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
737737Manhole
738738Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
739739centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
740740Supply and Fabrication placing posistion of Steel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
741741Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
742742Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
743743Ventilation
744744Supply and delivery of 50mm Gi pipe0.6Rm
74574550mm GI elbow2Nos
74674650mm GI tee1Nos
747747Cutting of 50mm GI pipe5Nos
748748Threading of 50mm GI pipe5Nos
749749supply of weld mesh with welding and fixing charges1Nos
75075050mm G.I Gate Valve2Nos
751751Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.12.87Sq.m
752752Repairs to 30000 Litre OHT Sivankoil
753753Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.20.74Sq.m
754754Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
755755Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
756756Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.157.72Sq.m
757757Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
758758Inner Ladder
759759RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
760760Supply, fabrication, placing in position of steel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
761761Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
762762Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
76376365mm G.I Gate Valve1Nos
764764Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
76576565mm G.I coupling1Nos
76676665mm G.I pipe6Rm
767767Repairs to 30000 Litre OHT AnnaNagar
768768Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.20.74Sq.m
769769Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the Departmental Officers.10.8Sq.m
770770Reinforced cement concrete 1 : 1 1/2: 3(one cement, oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by Departmental Officers.0.68Cu.m
771771Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.157.72Sq.m
772772Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
773773Inner Ladder
774774RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
775775Supply, fabrication, placing in position of steel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
776776Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
777777Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
77877865mm G.I Gate Valve1Nos
779779Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.13.82Sq.m
780780Repairs to 60000 Litre OHT Nagaraj Nagar
781781Plastering with cement mortar 1:3 (One Cement, Five Sand) 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.35.4Sq.m
782782Exterior Emulsion two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of First quality of approved colour over a Priming Coat including thorough scrapping, clean removal of dirt and including necessary plaster of paris putty wherever required etc, complete complying with standard specification.145.32Sq.m
783783Painting two coats over new iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete.6.93Sq.m
784784Inner Ladder
785785RCC 1:1.5:3 (one cement,one and half sand and three 20mm HBG stoneexcluding the cost of reinforcement and centering and shuttering but including curing finishing, etc.complete0.18Cu.m
786786Supply, fabrication, placing in position of steel rods cutting tying etc.complete including cost of reinfor cement RTS rods40.53Kg
787787Centering, for soffits of RCC works including strutting shuttering charges etc. complete3.24Sq.m
788788Labour charges for lowering and fixing of RCC ladder inside the OHT1Nos
789789Manhole
790790Supply and delivery of 25 x 25 x 6 mm angle for Supporting legs (1x4x0.75 = 3mx1.8kg/m = 5.4kg)5.4Kg
791791centering for soffits of RCC works including strutting shuttering charges etc complete (4x0.75x0.75)0.225Sq.mt
792792Supply and Fabrication placing posistion of Steel Rods cutting tieing etc complete inlcuding cost of Reinforecement RTS rods up to 16mm (2x4x0.7 = 5.6mx0.39=2.184kg)2.184Kg
793793Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly includingcost of mixing of concrete (1x0.75x0.75x0.075)0.042Cu.m
794794Labour charges fabricating the board including fixing of MS angle cutting bending welding charges using welder etc complete1Nos
795795Ventilation
796796Supply and delivery of 50mm Gi pipe0.6Rm
79779750mm GI elbow2Nos
79879850mm GI tee1Nos
799799Cutting of 50mm GI pipe5Nos
800800Threading of 50mm GI pipe5Nos
801801supply of weld mesh with welding and fixing charges1Nos
802802Scaffloding for painting using Plastering, whitewashing and coulor washing including cost and conveyance all materials and scaffolding charges etc., complete complying with standard specifications as directed by the departmental officers.20.41Sq.m
80380365mm G.I coupling2Nos
80480465mm G.I pipe6Rm
805805Construction of Road for Restoring the Cut Portion.
806806Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method).Grade III.1.44Cu.m
807807Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete.0.96Cu.m
808808Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.0.96Cu.m
809809To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101)(51971+13006)= 64977
810810To purchase of for 5 HP Submersible motor (75 x 175)5hp 3ph(88)(101) 17 (LPM) 77 (HEAD)1set
811811Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 1011set
812812Provision for Name Board1No
813813GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package}\n1GST Amount (in Rupees)

AI Tender Summary

OUR REF NO 25091321
AUTHORITY Local Bodies
TENDER VALUE 1.12 Crore
LAST DATE 14-08-2020
Authority
Authority Name Rural Development And Panchayats Department
Work Description Thanjavur District - Package No . 35 - Implementation Of Jjm To Provide Fhtc To Rural Households And Water Supply Works In Govindapuram , Malaiyappanallur And Srinivasanallur Panchayats In Thiruvidaimarudur Block Of Thanjavur District-Year 2020-21 .
Basic Detail
Tender No Rc.No.1325/2020/A3 dated.16.07.2020.
Bidding Type Tender
Location
City Thiruvidaimarudur
State Tamil Nadu
Key Dates
Publish Date 06 Aug 2020
Submission Date 14 Aug 2020
Open Date 14 Aug 2020
Finance
Tender Value 1.12 Crore
Tender Fee Ref. Documents
EMD 1.12 Lakhs
Exemption Not Available
Document List
652B3E86-ED11-499C-A4FD-497931D1A9F0.html
Tendernotice_1.pdf
BOQ_209316.xls
pkg.no.35.thiruvidaimarudur.technicalbid.pdf
pkg.no.35.thiruvidaimarudur.pricebid.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 14, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

652B3E86-ED11-499C-A4FD-497931D1A9F0.html

pdf

Tendernotice_1.pdf

xls

BOQ_209316.xls

no

pkg.no.35.thiruvidaimarudur.technicalbid.pdf

no

pkg.no.35.thiruvidaimarudur.pricebid.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders