Assistance In Carrying Out Miscellaneous Routine Works For Preventive Maintenance Of 132Kv Substation , Pithoragarh And 132Kv Substation , Bageshwar Under Oandm Division , Ptcul , Almora, Almora-Uttarakhand

Power Transmission Corporation Of Uttaranchal Limited has published Assistance In Carrying Out Miscellaneous Routine Works For Preventive Maintenance Of 132Kv Substation , Pithoragarh And 132Kv Substation , Bageshwar Under Oandm Division , Ptcul , Almora. Submission Date for this Tender is 03-09-2020. clocks Tenders in Almora Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

25089610
Assistance In Carrying Out Miscellaneous Routine Works For Preventive Maintenance Of 132Kv Substation , Pithoragarh And 132Kv Substation , Bageshwar Under Oandm Division , Ptcul , Almora
Open Tender
Indian
Uttarakhand
Almora
03-09-2020

Tender Details

Assistance In Carrying Out Miscellaneous Routine Works For Preventive Maintenance Of 132Kv Substation , Pithoragarh And 132Kv Substation , Bageshwar Under Oandm Division , Ptcul , Almora , Electrical Items : , Assistance In Electrical Preventive Maintenance Of 132Kv Substation , Pithoragarh And 132Kv Substation , Bageshwar By Carrying Out Following Miscellaneous Work On Routine Basis And With Round The Clock Availability Of Manpower . At 132Kv Substation , Pithoragarh:- 2X20 Mva ( 132/33Kv ) Transformers , 2X3x5 Mva ( 132/33Kv ) Transformers , 06 Nos . 132Kv Bays And 13 Nos . 33Kv Bays . At 132Kv Substation , Bageshwar:- 2X3x7 Mva ( 132/33Kv ) Transformers , 02 Nos . 132Kv Bays And 12 Nos . 33Kv Bays . Carrying Out Following Miscellaneous Works On Routine Basis And With Round The Clock Availability Of Manpower Under The Accompanying Technical Specifications . It Will Include Among Others As Specified Therein The Following:A ) Routine Visual Checking Of Red Hot Points , Flashpoints , Burned Jumpers Etc . In 132Kv & 33Kv Switchyards . General Routine Maintenance Of Outdoor Equipments/Panels In 132Kv & 33Kv Switchyards I . E . Cbs , Isolators , Bus Bars , Cts , Pts/Cvts , Marshalling Kiosks Etc . Including Scheduled Cleaning , Lubrication , Tightening Of Connections/Jumpers , Replacement Of Minor Damaged Parts Of Equipments , Replacement Of Jumpers/Clamps/ Connectors Etc . B ) Routine Cleaning Of All Transformers , Maintenance Of Cooling Fans I . E . Oiling , Greasing , Cleaning Etc . , Lt Electrical Connections , Cleaning Of Oil Collection Pits , Tightening Of Loose Connections . C ) Routine Checking Of Complete Length Of Control Cables And Power Cables Between Indoor Panels/Equipments And Outdoor Equipments/Kiosks/Panels , Cleaning , Replacement Of Damaged/Burned Cables , Tightening & Replacement Of Damaged Terminals/Connections/ Lugs Etc . , Re-Ferruling Whenever Required . D ) Routine Maintenance Of Battery Cells And Battery Chargers I . E . Daily Cleaning Of Battery Room & Battery Cells , Maintaining Fluid Level , Specific Gravity , Applying Of Petroleum Jelly Etc . E ) Routine Maintenance Of Indoor Panels In Control Room And Plcc Room I . E . Control & Relay Panels , Acdb & Dcdb System , Indoor Transformers , Indoor & Outdoor Illumination System Etc . Including Scheduled Cleaning , Lubrication , Tightening Of Connections/Terminals , Replacement Of Minor Damaged Parts Of Panels , Tracing Of Circuits Etc . F ) Routine Maintenance Of 5T Crane , Ac Outdoor Unit , Air Handling Unit , 132Kv Room And 33Kv Room Exhaust Fans , Maintenance Of Exhaust Fans Of Cable Vaults , Water Motor , 250 Kva Generator . G ) Routine Maintenance Of Complete Illumination System , Tightening Of Electrical Connections , Earthings , Lm Tower Lights , Switches , Complete 3 Phase Ac Crane , Ahu , Lighting Distribution Boards , 132Kv Gis Room Hanging Led Roof Lighting Etc . H ) Any Other Substation Electrical Maintenance Related Routine Works Assigned By Engineer Incharge As And When Required . At 132Kv S/S , Pithoragarh 01 No . Operation Signifies Deployment Of 02 Skilled And 02 Highly-Skilled Manpower For A Period Of 08 Hours . At 132Kv S/S , Bageshwar Signifies Deployment Of 01 Skilled And 01 Highly-Skilled Manpower For A Period Of 08 Hours . Total Operations At 132Kv S/S , Pithoragarh:- 300 ( Rate Rs . 3288 . 00 Per Operation ) . Total Operations At 132Kv S/S , Bageshwar:- 300 ( Rate Rs . 1644 . 00 Per Operation ) . , Mccb 3Ph 415V/230V 65Amps Thermal Release 25A-50A , Ml6 Contractor 230V Ac ( 2No+2Nc ) Or Equilant

Key Value

Document Fees
INR 1180 /-
EMD
INR 52500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Assistance in carrying out miscellaneous routine works for preventive maintenance of 132KV Substation, Pithoragarh and 132KVSubstation, Bageshwar under O&M Division, PTCUL, Almora
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Electrical Items :
2 1.01 Assistance in electrical preventive maintenance of 132KV Substation, Pithoragarh and 132KV Substation, Bageshwar by carrying out following miscellaneous work on routine basis and with round the clock availability of manpower.\nAt 132KV Substation, Pithoragarh:- 2x20 MVA (132/33KV) Transformers, 2x3x5 MVA (132/33KV) Transformers, 06 Nos. 132KV Bays and 13 Nos. 33KV Bays.\nAt 132KV Substation, Bageshwar:- 2x3x7 MVA (132/33KV) Transformers, 02 Nos. 132KV Bays and 12 Nos. 33KV Bays.\nCarrying out following miscellaneous works on routine basis and with round the clock availability of manpower under the accompanying Technical Specifications. It will include among others as specified therein the following:\na) Routine visual checking of red hot points, flashpoints, burned jumpers etc. in 132KV & 33KV switchyards. General routine maintenance of outdoor equipments/panels in 132KV & 33KV switchyards i.e. CBs, isolators, bus bars, CTs, PTs/CVTs, marshalling kiosks etc. including scheduled cleaning, lubrication, tightening of connections/jumpers, replacement of minor damaged parts of equipments, replacement of jumpers/clamps/ connectors etc.\nb) Routine cleaning of all transformers, maintenance of cooling fans i.e. oiling, greasing, cleaning etc. , LT electrical connections, cleaning of oil collection pits, tightening of loose connections.\nc) Routine checking of complete length of control cables and power cables between indoor panels/equipments and outdoor equipments/kiosks/panels, cleaning, replacement of damaged/burned cables, tightening & replacement of damaged terminals/connections/ lugs etc., re-ferruling whenever required.\nd) Routine maintenance of battery cells and battery chargers i.e. daily cleaning of battery room & battery cells, maintaining fluid level, specific gravity, applying of petroleum jelly etc.\ne) Routine maintenance of indoor panels in control room and PLCC room i.e. control & relay panels, ACDB & DCDB system, indoor transformers, indoor & outdoor illumination system etc. including scheduled cleaning, lubrication, tightening of connections/terminals, replacement of minor damaged parts of panels, tracing of circuits etc. \nf) Routine maintenance of 5T Crane, AC outdoor unit, Air Handling Unit, 132KV Room and 33KV Room Exhaust Fans, maintenance of exhaust fans of Cable vaults, Water motor, 250 KVA Generator.\ng) Routine maintenance of Complete illumination system, tightening of electrical connections, earthings, LM Tower Lights, switches, complete 3 phase AC crane, AHU, Lighting Distribution Boards, 132KV GIS Room hanging LED Roof lighting etc.\nh) Any other substation electrical maintenance related routine works assigned by engineer incharge as and when required. \nAt 132KV S/s, Pithoragarh 01 No. operation signifies deployment of 02 skilled and 02 Highly-skilled manpower for a period of 08 Hours.\nAt 132KV S/s, Bageshwar signifies deployment of 01 skilled and 01 Highly-skilled manpower for a period of 08 Hours.\nTotal operations at 132KV S/s, Pithoragarh:- 300 (Rate Rs. 3288.00 per operation).\nTotal operations at 132KV S/s, Bageshwar:- 300 (Rate Rs. 1644.00 per operation).\n item1 1 Operation
3 1.02 MCCB 3Ph 415V/230V 65Amps Thermal Release 25A-50A item2 62 Nos
4 1.03 ML6 Contractor 230V AC (2NO+2NC) or Equilant item3 43 Nos