Repair Maintenance Of Internal Electric Supply And Connected Item At J-2 ( Jawahar ) Location Under Ge ( East ) Jalandhar Cantt ( Tender Id No 2020_Mes_361136_1 )
Tender Value
20.82 Lakhs
Estimated cost
Bid Submission
24 Aug 2020
0 days left
EMD
41640
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar Cantt → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair Maintenance Of Internal Electric Supply And Connected Item At J-2 ( Jawahar ) Location Under Ge ( East ) Jalandhar Cantt ( Tender Id No 2020_Mes_361136_1 )
BOQ
| Name of Work: : Repair maintenance of internal electric supply and connected item at J-2 (Jawahar) Location under GE (East) Jalandhar Cantt (Tender ID No 2020_MES_361136_1) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Attending complaints of internal electrification received on phone or in person at complaint center for no light, voltage fluctuations, non-working of light fitting, ceiling fans, exhaust fans etc by checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires etc carrying out repairs such as tightening of loosen electric connections, switches, sockets, switch board, ceiling lights, wall light fittings, ceiling fans, fan regulators, electronic ballast, ceiling rose, MCBs /exhaust fans etc., whichever is required to make the item functional round the clock by deploying two electricians having ITI qualification with minimum 2 yrs experience or minimum 5 yrs experience in respective trade and two helpers to assist the service having minimum 2 yrs experience in respective trade with mobile phone without camera including necessary T&P and replacement of following spares complete all as specified and directed\nNote : The complaints given shall be attended within minimum possible time or maximum upto 24 Hours. If complaint not attended by the due time Rs. 500/- shall be deducted per complaint per day till the rectification time\n | 400 | Per Complaint | |
| 2 | 2 | Supply only switch modular type, 5 Amps, 240 Volt AC single pole, one way including taking down existing switch complete all as specified. | 300 | Each | |
| 3 | 3 | Supply only switch modular flush type, 15 Amps, 240 Volt AC single pole, one way including taking down existing switch complete all as specified | 30 | Each | |
| 4 | 4 | Supply only socket out let 5 Amp, 5 pin modular type including taking down existing socket complete all as specified | 200 | Each | |
| 5 | 5 | Supply only socket outlet multipurpose 3 in 1, 6 pin, 5 & 15 Amps, modular type including taking down existing socket complete all as specified | 30 | Each | |
| 6 | 6 | Supply only bell push switch modular type 5 Amps, SP, 240 volts including taking down existing bell complete all as specified | 20 | Each | |
| 7 | 7 | Supply only bell electric AC (Ding Dong) 240 volt SP including taking down existing bell complete all as specified. | 20 | Each | |
| 8 | 8 | Supply only Lamp holder insulated body with back plate suitable for batten fittings including taking down existing lamp holder complete all as specified. | 40 | Each | |
| 9 | 9 | Supply only fan step regulator, electronic type, modular type, single phase, 300 watt including connection wire after dismantling/ removing unserviceable regulator complete all as specified. | 100 | Each | |
| 10 | 10 | Supply only MCB SP 5 Amps to 30 Amps, 240V with rupturing capacity 10 KA including taking down existing MCB complete all as specified. | 120 | Each | |
| 11 | 11 | Supply only MCB SPN 5 Amps to 30 Amps, 240V with rupturing capacity 10 KA including taking down existing MCB complete all as specified. | 20 | Each | |
| 12 | 12 | Supply only LED bulb retrofit type 7 watt, B22, lumen output 1100, color temp 6500K including taking down existing CFL complete all as specified. | 120 | Each | |
| 13 | 13 | Taking down old unserviceable capacitor clamp and split pin and supply and fix capacitor clamp and split pin complete all as specified and directed | 20 | Each | |
| 14 | 14 | Supply only condenser 2.5/ 3.0/4.0 MFD suitable for ceiling/ exhaust fans including taking down existing complete all as specified. | 90 | Each | |
| 15 | 15 | Supply only 20mm dia rigid PVC conduit exclusive of boxes (junction/ terminal) but exclusive of all tees, bends, elbows, reducers, bell mouth tubs, ends and fixing, all accessories such as couplers, lock nuts, saddles, pipe clamps etc complete all as specified and directed | 100 | RM | |
| 16 | 16 | Supply only modular 3 module cover plates for fixing modular switch and sockets complete all as specified.\n | 15 | Each | |
| 17 | 17 | Supply only modular 4 module cover plates for fixing modular switch and sockets complete all as specified.\n | 15 | Each | |
| 18 | 18 | Supply only modular 8 module cover plates for fixing modular switch and sockets complete all as specified.\n | 40 | Each | |
| 19 | 19 | Supply and fixing in repairs sheet metal enclosure 2 way without bus bar with MCB, SPN 40 Amp, 10 KA, 'C' Series complete all as specified and directed | 11 | Each | |
| 20 | 20 | Taking down carefully existing point wiring of any type (i.e. on wooden batten, surface conduit, casing capping or concealed conduit) complete for light, fan socket or power point with fitting Supply and fixing fixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawl plug, screw etc including removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed | 29 | Per Point | |
| 21 | 21 | Material and labour for point wiring with 1.5 sqmm (nominal area), 1100 volt grade PVC insulated FRLS type multi stranded copper conductor cable drawn in and including concealed rigid PVC conduit, size 25mm dia ISI marked medium grade with accessories including cutting chases for laying of conduit/ fixing of boxes in walls/ floors etc including making good to disturbed surfaces as per adjoining specification and terminated in concealed terminal boxes including MS concealed terminal boxes with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with washers and earth continuity PVC insulated FRLS type cable with stranded copper conductor of size 1.5 sqmm (nominal area) green colour as earth wire connected with earth dolly for one light/fan point controlled one switch complete all as specified and as directed. | 15 | Per Point | |
| 22 | 22 | All as per item No. 21.00 here-in-before but for one outlet socket 3 pin 5 Amps on independent board. | 10 | Per Point | |
| 23 | 23 | All as per item No. 21.00 but 3 pin 15 Amp socket outlet with 4.0 sqmm PVC insulated FRLS copper cable and 2.5 sqmm PVC insulated FRLS copper cable for continuous earth continuity conductor all as specified and directed. | 4 | Per Point | |
| 24 | 24 | Supply and fixing in replacement ceiling surface LED light fitting of 10 W white powder coated CRCA housing and PMMA dome diffuser, including taking out old broken shade and making good the existing disturb surface complete all as specified and directed. | 10 | Each | |
| 25 | 25 | Supply and fixing flexible cord PVC insulated FRLS type with stranded copper conductor wire of size 23/0.0076 sqmm 3 core including taking down existing cable complete all as specified and directed. | 100 | RM | |
| 26 | 26 | Supply and fixing in replacement of ball bearing 6201 of ceiling fan complete including testing of fans complete all as specified and directed\n | 55 | Each | |
| 27 | 27 | Supply and fixing in replacement of ball bearing 6202 of ceiling fan complete including testing of fans complete all as specified and directed\n | 50 | Each | |
| 28 | 28 | Material and labour for rewinding of ceiling fan motor 240 volt, 50 Hz, 1400 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia upto connector block complete all as specified and directed. | 40 | Each Job | |
| 29 | 29 | Material and labour for rewinding of ceiling fan motor 240 volt, 50 Hz, 1200 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia upto connector block complete all as specified and directed. | 50 | Each Job | |
| 30 | 30 | Material and labour for rewinding of exhaust fan motor 240 volt, 50 Hz, 300 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia upto connector block complete all as specified and directed. | 30 | Each Job | |
| 31 | 31 | Supply and fixing in replacement PVC connection hot and cold water pipe 18\" long, 15mm outer dia with brass nut and washer, both side complete all as specified and directed. | 80 | Each | |
| 32 | 32 | Material and labour for new decorative wall light fixture made up of polycarbonate, suitable for 5/7/9 W retrofit LED lamp (Spiral B-22 base) 230V, prewired including removing old fitting complete all as specified and directed | 50 | Each | |
| 33 | 33 | Supply and fixing in replacement of energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP 65 flood light 120 watt with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose with necessary clamps, nuts and bolts and making necessary connections including taking down complete all as specified and directed | 6 | Each | |
| 34 | 34 | Supply and fixing surface mounting energy saving LED tube light fitting, T8 (4 ft), 1 x 18 W, 6500 K, 2100 lumen, 230 V, ultra bright, glass shell, glare free, white light, wide angle, double side connection retrofit with G 13 lamp holders with inbuilt driver and retrofit LED tube rod including pre-coated CRCA covered batten, box type, prewired including removing old fitting complete all as specified and directed. | 255 | Each | |
| 35 | 35 | Supply and fixing in replacement automatic street light switch comprising of nature switch for automatic switching of street light based on LUX level of natural light or time periodicity (both options) the infrared sensor based nature switch alongwith lighting load of 3 KW single phase power contractor (AC3) 25 Amp and MCB SP on both in and outside of rating 25 Amp complete enclosed in outdoor, rust weatherproof and terminate proof FR grade SMC lockable box conforming to IP 54 contractor. MCB and circuit wiring should be 10 sqmm copper wire complete all as specified and directed. | 2 | Each | |
| 36 | 36 | Suppy and laying cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sqmm 3½ core complete all as specified and directed | 100 | RM | |
| 37 | 37 | All as per Srl Item No. 36.00 here-in-before but 95 sqmm 3½ core | 100 | RM | |
| 38 | 38 | All as per Srl Item No. 36.00 here-in-before but 16 sqmm 4 core | 100 | RM | |
| 39 | 39 | All as per Srl Item No. 36.00 here-in-before but 10 sqmm 2 core | 70 | RM | |
| 40 | 40 | Excavation in trenches in soft/ loose soil n. exc. 1.50 mtr wide and n. exc. 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed. | 35 | CUM | |
| 41 | 41 | Removal of surplus soil to a distance n. exc. 50 mtr and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed. | 4 | CUM | |
| 42 | 42 | Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25 cm thick each layer complete all as specified and directed. | 26 | CUM | |
| 43 | 43 | Material and labour for sand for cushioning with 8cm thick layer before laying of cable and 15cm thick layer after laying of cable in trenches complete all as specified and directed. | 4 | CUM | |
| 44 | 44 | Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed. | 2.5 | Per 1000 No. | |
| 45 | 45 | Material and labour for earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level covered on all sides with alternative layers of charcol dust and common salt 15 cm thick connected to galvanised earth lead Galvanised Iron strip 32 x 6 cm by means of bolts, nuts, check nuts and washers of Galvanised Iron or steel with protection pipe earth wire protected by galvanized steel pipe light grade 40 mm bore from top of the earth plate electrode upto test point and watering pipe 20mm bore, GI light grade with funnel and wire mesh all as shawn in electrical plate No 3 of SSR Part-1 and connected to earthing test point all as specified or indicated and testing on completion, including PCC earth pit (1:3:6) type C-2 RCC covered with CI cover hinged with frame including excavation and earth work complete all as specified.\nNote : 1. If result is not satisfactory then contractor will do 2nd earthing on his own cost.\n2. Contractor will give 2 years warranty of earthing in writing. | 8 | Each | |
| 46 | 46 | Supply and fixing factory made junction box of size 250 x 300 x 125mm suitable for street light fixed on pole, made out of CRCA sheet 2mm thick having front hinged shutter with lockable arrangements, outdoor type, weather proof duly painted with two coats of synthetic enameled paint over a coat of red oxide primer, having the provision to connect incoming and outgoing cable of size 16 sqmm 2 core and one number MCB SP, 10 KA, C-curve, 6 Amps, 240 volts and earthing plug complete all as specified and directed.\nNote : MS Clamps , nuts, bolts required to fixing on pole shall be measured and paid separately. | 15 | Each | |
| 47 | 47 | Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volts, power factor 0.95 suitable for LED street light of capacity 45W complete all as specified and directed. | 10 | Each | |
| 48 | 48 | Supply and fixing in replacement new generation, post-top, gate light energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source 25W, 5700K complete all as specified and directed. | 5 | Each | |
| 49 | 49 | Supply and fixing GI pipe light grade ISI marked of size 40mm bore for cable protection including provision of PVC heavy duty bends complete for fixing along road/ floor along the pole including fittings complete all as specified. | 15 | RM | |
| 50 | 50 | Supply, fixing and testing after jointing cable jointing kit suitable for XLPE armoured aluminium cable of size 95 sqmm 3 core 11 KV grade cable for outdoor type termination cold shrinkable joint complete with jointing material and accessories complete all as specified and directed. | 2 | Each | |
| 51 | 51 | Supply and fixing in replacement cable jointing kit for XLPE armoured aluminium cable of size 95 sqmm 3 core 11 KV grade cable for indoor type terminal joint cold shrinkable joint complete with jointing material and accessories complete all as specified and directed | 1 | Each | |
| 52 | 52 | Cleaning and preparation of old painted surface of 4 pole structure and painting with one coat of aluminium paint to all steel structure such as channel/ brackets, bracing, clamps, anti climbing device, cross arms and marking 30cm high alternate black & white strips with synthetic enameled paint upto 1.5 mtr height and writing pole Nos and applying one coat of cement base paint on PCC coping complete all as specified and directed. | 1 | Each Job | |
| 53 | 53 | Material and labour for preparation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alternate black & white strips of 30cm each upto 1.5 mtr height from top of PCC coping and numbering of poles including painting of street light brackets, clamps etc complete all as specified and directed. | 10 | Each Pole | |
| 54 | 54 | Material and labour for preparation of old painted surface of steel tubular poles straight/ swan neck and applying two coats of synthetic enamel paint in alternate black & white strips of 30cm each upto 1.5 mtr height from top of PCC coping and two coats of aluminium paint to remaining part of poles above strips including painting of street light brackets, clamps and numbering the pole complete all as specified and directed. | 20 | Each Pole | |
| 55 | 55 | Material and labour for in replacement MCCB 63 Amps, 4 pole, 415 Volts, 50 Hz, having rupturing capacity 16 KA complete all as specified and directed. | 7 | Each | |
| 56 | 56 | Material and labour for in replacement MCCB 100 Amps, 4 pole, with thermal magnetic release, ICS=ICU=100%, 415 volts, 50 HZ, 16 KA complete all as specified and directed | 2 | Each | |
| 57 | 57 | Material and labour for in replacement MCCB 400 Amps, 4 pole, 415 Volts, 50 Hz, having rupturing capacity 36 KA complete all as specified and directed. | 1 | Each | |
| 58 | 58 | Supply and fixing in replacement DOL starter for submersible pump including voltmeter with selector switch, ammeter with selector switch, 4 pole contactor, overload relay, single phase preventer, MCB (incomer), indicator lamp, start & stop push button of capacity 7.5 HP, 415 volt complete all as specified | 2 | Each | |
| 59 | 59 | Supply and fixing DOL starter in sheet enclosure type suitable for 3 phases, 415V, 50 Hz pump set 5 HP relay range 12-18 Amps reference (BE1-Dx A204-321) including taking down existing defective star delta starter complete all as specified and directed | 1 | Each | |
| 60 | 60 | Repair, maintenance & overhauling of existing 11KV A.B switch of any type & size including cleaning of insulator, male & female contacts, greasing & oiling to operating mechanism, setting of contracts, renewals of connections etc all for smooth functioning of A.B switch complete all as specified and directed | 1 | Each Set | |
| 61 | 61 | Surface clearing by cutting shrubs, vegetation, grass, bushes, weeds & trees upto 30cm girth, sweeping & removing the same to distance n.exc 50m away from the installations complete all as specified and directed | 100 | Sqm | |
| 62 | 62 | Supplying and erecting pre-stressed concrete pole 9.0 metres long, 102 x 172mm at top and 102 x 279mm at bottom, class 10, complete all as specified including painting of poles with two coats of synthetic enamel paint over a coat of primer in 30cm wide black & white strips upto 1.5m height from top of PCC coping and numbering of poles complete all as specified and directed. (PCC and earth work shall be measured & paid for separately) | 2 | Each | |
| 63 | 63 | Material and labour for servicing and repairing/ carrying out maintenance of 11KV/ 433V transformer of upto 630KVa capacities complete all as specified and directed including the following works :-\n(a) Removing from platform and disconnecting electrical connection from HT and LT side including transporting the transformer to workshop.\n(b) Dismantling the transformer, drain out transformer oil, lift the cover, coil assembly, keep up the assembly in oven upto the preparation of inside chambers by cleaning inside, scraping complete all around old parts of the transformer.\n(iii) Applying two coats of oil resistance painting internal (inside transformer) over a coat of red oxide primer.\n(iv) Cleaning the core iron sheet laminations assembly by oil complete, removing the carbon sediments, dust in the coil and core gently without making any damage to coil and core.\n9v) Reassembling the dismantled parts including provision of new gasket, nut, bolts, refilling with transformer oil and transporting back to original location including electric connection testing and commissioning etc complete.\nNotes : (a) Oil filtration, supply of new oil will be measured separately.\n(b) All petty parts including nuts, bolts, gasket, minor welding etc are deemed to be included the quoted rate.\n(c) The cost for transport and lifting of transformer by crane etc shall be deemed to include in the quoted rate\n | 2 | Each Job | |
| 64 | 64 | Supply and fixing HT bushes including insulators, washers weather proof gaskets, bolts, nuts etc for 630 KVA transformers at various locations including taking down unserviceable one complete all as specified and directed | 1 | Set of three | |
| 65 | 65 | Supply and fixing LT bushes including insulators, washers weather proof gaskets, bolts, nuts etc for 630 KVA transformers at various locations including taking down unserviceable one complete all as specified and directed | 1 | Set of four | |
| 66 | 66 | Material and labour for conducting oil filtration by steam line type filter machine to improve the break down value (BDV) not less than 60 KV RMS and de-moisturizing by heating upto the required level to achieve the dielectric strength of transformer oil complete all as specified and directed | 500 | Ltrs | |
| 67 | 67 | Supply and filling transformer oil with correct dielectric strength for topping up/ replacing the oil in transformers and PTs at various location complete all as specified and directed | 200 | Ltrs | |
| 68 | 68 | Supply and fixing breather unit with superior quality blue colour silica jell and fill up the oil, to maintain the exact value grade for transformer of capacity of 630 KVA including taking down unserviceable one complete all as specified and directed | 1 | Each | |
| 69 | 69 | Material and labour for applying one coat of synthetic enamel paint to the surface of all GI/ CI pipe of any size inside/ outside of pump house complete all as specified and directed.\nNote : The surface of GI/ CI pipe shall be painted with black colour\n | 2 | Each Job | |
| 70 | 70 | Repair to water leakage of inlet pipe connected to float valve of RCC/ PVC service tanks by removing short piece of pipe/ barrel nipple and replace with suitable barrel nipple, socket, elbow and rectify the water leakage by using the water proofing material complete all as specified and directed. | 23 | Each Job | |
| 71 | 71 | Cleaning of overhead service water tank of RCC/ PVC n.exc 500 ltrs capacity and the connected circulating pipes at any position by removing sludge, mud, moss, moulds efflorescent salts, oil spots etc or any other foreign materials from the bottom, cover and internal surface by scrapping using wire brush, draining out the washed water from the tank and washing internally by using bleaching powder and again draining out the water from the tank and applying two coat of white lime wash to RCC tank and rewriting the date of cleaning with white paint on black background complete all as specified and directed | 15 | Each Job | |
| 72 | 72 | Cleaning of over head service water tank of RCC/ PVC exc 500 ltrs but n.exc 1000 ltrs capacity and the connected circulating pipes at any position by removing sludge, mud, moss, moulds efflorescent salts, oil spots etc or any other foreign materials from the bottom, cover and internal surface by scrapping using wire brush, draining out the washed water from the tank and washing internally by using bleaching powder and again draining out the water from the tank and applying two coat of white lime wash to RCC tank and rewriting the date of cleaning with white paint on black background complete all as specified and directed | 5 | Each Job | |
| 73 | 73 | Cleaning of 40000 gallon capacity underground sump at pump house No 1 and 2 by draining out water from the tank with portable pump sets, removing sludge, mud or any other foreign materials from the bottom and internal surface and cleaning by wire brushing, washing internally by using bleaching powder and applying 2 coats of white lime wash including re-writing the date of cleaning, capacity of the tank etc with white flourscent white paint on black background complete all as specified and directed | 1 | Each Job | |
| 74 | 74 | Supply and fixing in repairs 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe (Minimum weight 142 gms) complete all as specified and directed. | 70 | Each | |
| 75 | 75 | Supply and fixing 100mm dia cast iron foot valve suitable for sewage pump including dismantling the old unserviceable one complete all as specified and directed. | 2 | Each | |
| 76 | 76 | Material and labour for scraping old paint from transformer 400 KVA/ 630 KVA with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint in steel grey by using spray gun or approved suitable paint after taking proper shut down complete all as specified and directed. | 1 | Each Job | |
| 77 | 77 | Attending complaints by deploying labour for repair to leakage/ blockage of water carrying pipes size 25mm to 200mm of any description such as CI/ GI/ DI sluice valve at any location including excavation & earth work, cutting existing pipe lines, dewatering etc all as specified.\nNote :-\n(a) Excavation/ earth work upto one meter required will be included in quoted rate.\n(b) Rate quoted shall be deemed inclusive of necessary T&P required.\n(c) Rectification of defects in any type & size of pipe/ sluice valve etc including bailing out water if any and all as directed at site\n(d) Cost of nuts, bolts, washers, gasket of any type and size, cutting of pipe, jointing and other minor parts shall be deemed to be included in quoted rate. | 150 | Per Complaint | |
| 78 | 78 | Supply and fixing GI tubing medium grade 50mm bore (in any length) with required fitting duly laid in trenches and connecting up with water supply mains including removing unserviceable tubing complete all as specified | 25 | RM | |
| 79 | 79 | All as per Srl Item No. 78.00 here-in-before but 25mm bore | 30 | RM | |
| 80 | 80 | All as per Srl Item No. 78.00 here-in-before but 15mm bore | 70 | RM | |
| 81 | 81 | Material and labour for disconnecting electric connection, pipe connection and taking out submersible pump & motor of capacity 7.5 HP from bore well/ sump and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same gauge and weight to existing including replacement of motor bush, thrust plate coupling complete with key and reassembling the motor and lowering it into bore well making it functional and testing complete all as specified | 2 | Each Job | |
| 82 | 82 | Supply and fixing lowering PVC insulated & PVC sheathed industrial 6 Sqmm 3 core flat submersible cables with bare bunched copper conductor for submersible pump motors with voltage grade 1100 volts generally conforming to IS 694/1990 complete all as specified and directed. | 110 | RM | |
| 83 | 83 | Rewinding of induction electric motor upto 15 HP, 3 phase 440 V AC using super enameled copper winding wire of gauge equal to existing replacing ‘E’ class insulation sheet, sleeve, varnishing the same, cleaning, washing ball bearing with kerosene oil, greasing with new grease of make ‘Castrol’ reassembling the motor testing and commissioning complete all as specified | 25 | Kg | |
| 84 | 84 | Supply and fixing 40mm gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified | 2 | Each | |
| 85 | 85 | All as per Srl Item No. 84.00 here-in-before but 25mm | 4 | Each | |
| 86 | 86 | All as per Srl Item No. 84.00 here-in-before but 80mm | 2 | Each | |
| 87 | 87 | Attending of complaints of refrigeration, AC such as not working of split AC, water cooler, refrigerators and deep freezers etc., required to make the item functional round the clock by deploying skilled suitable tradesman including necessary T&P and replacement of following spars complete all as specified and directed.\nNote : The complaints given shall be attended within minimum possible time or maximum upto 24 hours. If complaints not attended by the due time Rs. 500/- shall be deduced per complaint per day till the rectification time. | 150 | Per Complaint | |
| 88 | 88 | Supply only heating element 1500 Watt including taking old one complete all as specified and directed\n | 20 | Each | |
| 89 | 89 | Supply only thermostat for geyser of capacity 35/ 25 Ltrs including taking old one complete all as specified and directed\n | 35 | Each | |
| 90 | 90 | Supply only solar water heating element 3 KW Single phase, 230 Volts, ISI marked as per existing type and size including taking old one complete all as specified & directed. | 4 | Each | |
| 91 | 91 | Supply only thermostat switch suitable for solar water heater of capacity 500 LPD including taking old one complete all as specified & directed. | 4 | Each | |
| 92 | 92 | Material and labour for re-painting of evaporative air cooler (desert cooler) of capacity 5000 cum/ hr discharge, 40 ltr internally and externally including removing of old paint and preparing of surface for repainting and applying two coats of synthetic enamel paint by using spray gun complete all as specified and directed | 80 | Each Job | |
| 93 | 93 | Supply and fixing in repair of front air grill of desert cooler of capacity 40 ltr complete all as specified and directed | 8 | Each | |
| 94 | 94 | Material and labour for outer body of evaporative air cooler (Desert Cooler) of capacity 5000 Cum/Hrs discharge, 40 Ltr as per existing size including side grill as per existing type duly painted complete internally and externally with two coats of super enameled paint over a coat of red oxide primer complete all as specified and directed | 25 | Each | |
| 95 | 95 | Supply and fixing in repair submersible water pump (tullu pump) of capacity 18 watt single phase 220 volts for evaporative air cooler (desert cooler) of capacity 5000 cum/ hr discharge complete with switch/ wiring etc, complete all as specified and directed | 80 | Each | |
| 96 | 96 | Supply & replacement of wood wool pad for desert cooler set (03 Nos) of any size complete all as specified and directed | 60 | Each Set | |
| 97 | 97 | Supply and fixing in repair heat collector glass size 80\"x40\" suitable for solar water heaters of capacity 500 LPD as per existing type and thickness complete all as specified & directed | 6 | Each | |
| 98 | 98 | Supply and fixing in replacement geyser inner water tank S/S or copper suitable for Geyser Capacity 35 Ltrs as per existing shape and type complete all as specified & directed. | 15 | Each | |
| 99 | 99 | Material and labour for charging of refrigerant gas in split type AC 1.5 Ton capacity including vaccumizing, leakage test and rectification of leakages etc complete all as specified and directed. | 10 | Each Job | |
| 100 | 100 | Supply and fixing in replacement evaporative coil made out of copper pipe and fins suitable for split type AC 1.5 TR as per existing size and type including cutting, soldering, brazing and testing and charging of gas as required for air conditioner functional complete all as specified. | 5 | Each | |
| 101 | 101 | Supply and fixing AC box single pole & neutral sheet metal enclosure with 2 pin plus earth, 230 volts AC plug and socket suitable for MCB SPN,20 Amp complete all as specified. | 8 | Each | |
| 102 | 102 | Taking down old and unserviceable compressor and Supply and fixing new sealed compressor unit for water cooler of capacity 80 Ltrs including cleaning, vaccumizing, gas charging and testing on load complete all as specified and directed. | 2 | Each | |
| 103 | 103 | Supply and fixing in replacement for PCB remote plate of AC split type 1.5/2 Ton of make Voltas/ Carrier complete with remote, all as directed. | 8 | Each | |
| 104 | 104 | Material and labour for replacement of compressor sealed unit of capacity 1.5 TR unit suitable for Air conditioners split type including taking out to old unserviceable compressor and cleaning, flushing, vaccumizing the system, re-charging of gas in adequate quantity, soldering, brazing of suction, discharge and charging line complete all as specified and directed. \n | 8 | Each | |
| 105 | 105 | Material and labour for servicing and maintenance of AC's split type of capacity 1.5/2 TR inner & outer unit of any make, cleaning of condenser unit and evaporator unit with chemical solution C-Shine or equivalent, washing of air filter, descaling and cleaning of condensed water pipe, oiling and tightening of all nut, bolts etc complete all as directed. | 11 | Each | |
| 106 | 106 | Taking down old unserviceable sealed compressor and Supply and fixing of new compressor sealed unit suitable for refrigerator 415 to 551 Ltrs capacity including cleaning, vaccumizing, gas charging of adequate quantity and testing on load complete all as specified and directed\n | 4 | Each | |
| 107 | 107 | Material and labour for servicing and maintenance refrigerator 415 to 551 ltrs any make cleaning with acid solution & oiling any tightening of all nuts, bolts etc complete all as specified and directed | 10 | Each | |
| 108 | 108 | Supply and fixing in repair top plug 15/16 Amp complete all as specified and directed | 20 | Each | |
| 109 | 109 | Repair/ replacement of pressure gauge 4” dia 0 to 14 Kg/cm2 complete all as specified and directed\n | 10 | Each |
AI Tender Summary
Tender Timeline
Aug 04, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 26, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender