Provision Of Perimeter Light Security Light And Provision Of Certain Revenue And Minor Work Of Br Nature At Basoli Under Ge Basoli, GE Basoli-Jammu And Kashmir

Military Engineer Services-MES has published Provision Of Perimeter Light Security Light And Provision Of Certain Revenue And Minor Work Of Br Nature At Basoli Under Ge Basoli. Submission Date for this Tender is 19-08-2020. LED Light Tenders in GE Basoli Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

25056342
Corrigendum : Provision Of Perimeter Light Security Light And Provision Of Certain Revenue And Minor Work Of Br Nature At Basoli Under Ge Basoli
Open Tender
Indian
Jammu And Kashmir
GE Basoli
19-08-2020

Tender Details

Provision Of Perimeter Light Security Light And Provision Of Certain Revenue And Minor Work Of Br Nature At Basoli Under Ge Basoli

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Aug-2020 BOQ of subject tender is hereby revised due to certain amendment and other corr BOQ 19-08-2020
2 12-Aug-2020 1 BOQ of subject tender is hereby revised due to certain amendment BOQ 19-08-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 99800.0 /-
Tender Value
INR 49.90 Lakhs /-

BOQ Items

Name of Work: : Provn of Perimeter light, Security light and provn of certain revenue and minor work of BR nature at Basoli under GE Basoli
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed. 110.5 Sqm
2 2 Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and directed. 1187.8 Cum
3 3 Excavating in post holes (or similar holes) each n exc 0.5 cum getting out ,returning,filling in and ramming earth or broken rubble mixed with earth ,in layers n exc 25 cm ,watering and removing surplus soil to a distance n exc 50 m and making good surface in any type of soil complete all as specified and directed. 16 Each
4 4 M&L PCC 1:4:8 type D-2 ( Using 40mm graded crushed stone aggregate ) in foundation filling and mass concrete complete all as specified and directed. 10.3 Cum
5 5 M&L PCC 1:3:6 type C-2 ( Using 40mm graded crushed stone aggregate ) in foundation filling and mass concrete complete all as specified and directed. 69.71 Cum
6 6 M&L for brick work with old size sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 complete all as specified and directed. 53.55 Cum
7 7 Supply and fixing MS tube for steel work in tubular trusses including columns purlin rafter etc complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. -240 and it is painted one coat of zinc chromate primer paint (including preparation of surface) complete all as specified and directed. 1215 kg
8 8 Supply and fix for Mild steel screw bolts (machine made ) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 cm long.Supplied and fixed (diameter of neck 5 to 10 mm)complete all as specified and directed. 1 kg
9 9 Supply and fix for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding/Eaves board to wall, fixed with self tapping screws complete all as specified and directed. 1.5 Sqm
10 10 Supply and fix for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws . complete all as specified and directed. 86 Sqm
11 11 Providing, cement concrete Type B-1 1:2:4 (20 mm graded aggregate) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rouinded for chamfered angles and throating, as directing complete all as specified and directed . 3.7 Cum
12 12 M&L for M-25 Design mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete (using 20 mm graded crushed stone aggregate) complete all as specified and directed . 4.25 Cum
13 13 M&L for M-25 Design mix as in Columns, pillars, piers, posts and struts (using 20 mm graded crushed stone aggregate) complete all as specified and directed . 17.1 Cum
14 14 M&L for M-25 design mix as in beams, cantilevers, bressummers, lintels over 1.5m span (using 20mm graded crushed stone aggregate) complete all as specified and directed 1.5 Cum
15 15 M&L for M-25 Design mix as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and stair case slab, in shelves, parapets, railing and like(using 20 mm graded crushed stone aggregate) complete all as specified and directed . 4 Cum
16 16 TMT Mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed . 278 Kg
17 17 All as per item No 16 above but 6 mm to 8mm dia 50 Kg
18 18 All as per item No 16 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders 112 Kg
19 19 Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and sofits of foundation and plinth beams; and similar works; vertical or to batter for rough finished flat surfaces complete all as specified and directed. 14.31 Sqm
20 20 Form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and directed. 30.5 Sqm
21 21 Form work to soffits of suspended slabs such as roof slabs, floor slabs etc not exceeding 200mm thick complete all as specified and directed. 35.3 Sqm
22 22 Form work to soffits and sides of roof beam finished as ruf finish surface complete all as specified and directed. 30 Sqm
23 23 Form work to edges of concrete flats, breaks in floors, openings in concrete walls,floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work all exceeding 10 cm wide but not exceeding 20cm for rough finished flat surfaces of concrete complete all as specified and directed. 38 RM
24 24 Taking down cement plaster on brick or concrete surface including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed. 114.5 Sqm
25 25 Supply only integral water proofing compound complete all as specified and directed. 5 Kg
26 26 Rendering 15mm thick on brick work or concrete surfaces as in wall in cement mortar 1:4 finished surface even and smooth without using extra cement complete all as specified and directed. 355 Sqm
27 27 Rendering 15mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. 70 Sqm
28 28 Rendering 5mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished surface even and smooth without using extra cement complete all as specified and directed. 18 Sqm
29 29 Earth filling under floor including spreading, levelling, watering and well ramming in layers not exc 25 cm each complete all as specified and directed. 1.2 Cum
30 30 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft / loose soil. complete all as specified and directed. 911.8 Cum
31 31 Removing excavated material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point complete all as specified and directed. 314.78 Cum
32 32 M&L hardcore of broken stone or boulders. gauge n.exc 63mm, deposited spread and leveled in layers n.exc 15cm thick. Watered hand rammed to a true surface, complete all as specified and directed. 8.4 Cum
33 33 Dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed. 45 Sqm
34 34 M&L Glazed ceramic tiles in vertical surface 450x300mmx7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 10mm thick rendering in CM 1:4 complete all as specified and directed. 126 Sqm
35 35 M&L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including Screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 for laying tiles complete all as specified and directed. 71 Sqm
36 36 Roughening Surfaces of old Concrete Floor by Picking, sweeping Clean and Washing down with water to remove dust,etc and applying neat cement slurry @3kg/Sqm, complete, all as specified and directed. 91 Sqm
37 37 Plain cement concrete 25mm thick 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) as in floor, complete, all as specified and directed. 13 Sqm
38 38 Plain cement concrete 40mm thick 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in floor, complete, all as specified and directed. 40 Sqm
39 39 Plain cement concrete 50mm thick 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in floor, complete, all as specified and directed. 3 Sqm
40 40 Plain cement concrete 100mm thick 1:3:6 type C-2 using 40 mm graded stone aggregate as in path/floor laid in panel and joint filled with mastic filling complete, all as specified and directed . 83 Sqm
41 41 Plain cement concrete 50mm thick 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub floor, sub base complete, all as specified and directed . 13 Sqm
42 42 Plain cement concrete 75mm thick 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub floor, sub base complete, all as specified and directed . 80 Sqm
43 43 M&L for providing 75mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. 28 Sqm
44 44 Material and labour for approved quality sand filling as in floor complete all as specified and directed .\n 1.25 Cum
45 45 Material and labour for Machine pressed precast concrete interlocking paver block(coloured) with grey cement and pigment any shape and size, M-35 grade 60mm thickness conforming to IS-15658-2006 complete all as specified and directed .\n 45 Sqm
46 46 S&F steel window/ventilaters including 10mm Sq bar grill factory made out of box type frame and shutter (double shutter, one for glazing another for fly proofing) made out of section using flash butt welding, hinges shall be provided to both shutters complete including all fittings all as per drg No CEPZ/TD/27/13 Sh 1/4 to 4/4 all as complete all as specified and directed. 1.6 Sqm
47 47 Taking down chowkats or frames with shutters (w/o taking off shutters from the frame) n.exc. 1.5 Sqm each complete all as specified and directed 8 Each
48 48 Taking down chowkats or frames with shutters (w/o taking off shutters from the frame) exc. 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed . 2 Each
49 49 Supply and fix Solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification & drawing complete all as specified and directed.. 19.8 RM
50 50 Supply and fix Factory made solid panel PVC door shutter 30mm thick(style) consisting of frame shall be covered with heat moulded wood grain printed 5mm thick PVC sheet x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90") used insted of exposed portion of PVC sheet beading with solvent cement for stiles and PVC sheets for top rail, lock rail & bathroom rail on either side & as gap insert for rail & bottom rail, panelling of wood drained PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC beading and joined together with solvent cement including 100 mm size PTMT hinges, supplying & fixing in the frame at site as per specification & drawing 1.5 Sqm
51 51 Supply and fix UV coated medium density PVC board 20mm thick prelaminated one side with decorative choice lamination and other side balancing white lamination 2,4 and 6 design and back plain fixed with screws to timber/angle iron frame work etc complete all as specified and directed.. 4.1 Sqm
52 52 S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.. 2 Sqm
53 53 S&FGalvanised MS wire cloth 0.46mm nominal dia of wire and average width of aperature 1.18mm, complete all as specified and directed.. 1 Sqm
54 54 S&F Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt,complete all as specified and directed.. 16 Each
55 55 S&F Extruded aluminium alloy handles fabricated type anodised and fixed, 150 mm size complete, all as specified and directed. 8 Each
56 56 Supply and fix for 100mm size hasp and staple safety type aluminum anodized with mild steel hinges pin including bolt to hinge plate and fixed with screw complete all as specified and directed. 1 Each
57 57 Supply and fix for mild steel cold rolled butt hinges medium weight 100 mm long complete all as specified and directed. 3 Each
58 58 M&L for preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed. 62 Sqm
59 59 M&L for applying three coats of white washing on walls including preparation of newly plastered surfaces complete all as specified and directed. 73.49 Sqm
60 60 M&L for preperation of new plastered surface of wall and applying two coat of cement base paint over a coat of primer, complete all as specified and directed. 302.88 Sqm
61 61 M&L for applying three coats of white washing on ceiling including preparation of newly plastered surfaces complete all as specified and directed. 10 Sqm
62 62 Supply and fix Vitreous China wash down water closet panPedestal pattern) , including seat and cover connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor complete all as specified. 1 Each
63 63 Supply and fix in repair for Vitreous Chinaware squatting pan, orissa pattern size 580mm x 440mm white , with integral foot rests, including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor complete all as specified. 4 Each
64 64 Supply and fix 10 ltr capacity PVC valveless, syphonic action type flushing cistern low level white with inlet, ball valve, float and handle including flush pipe of 32mm dia connection to pipe complete all as specified and directed. 8 Each
65 65 Supply and fix vitreous china wash hand basin white flat back of size 550x400 mm including bracket, cutting for and pinning the ends of brackets or erecting stands exclusive of waste pipe but including PTMT 32mm waste coupling and waste pipe, complete all as specified and directed. 2 Each
66 66 Supply and fix Chromium plated brass shower rose with or without swivel joints, 125 mm size including fixing to steel pipe or union,complete all as specified and directed. 1 Each
67 67 Supply and fix 15 mm dia bore Bib taps,fancy type , cast copper alloy, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed complete all as specified. complete all as specified and directed. 10 Each
68 68 Supply and fix in repair for 15mm dia bore Stop valve fancy type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed 4 Each
69 69 Supply and fix in repair for 20mm dia bore Stop valve fancy type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed 1 Each
70 70 Supply and fix in repair for 15mm dia bore Stop valve concealed type,long shank cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed 10 Each
71 71 Taking down steel water tubing of 15/20mm dia including all fittings complete all as specified and directed.\n 30 RM
72 72 Supply and fix for steel water tubing galvanised, 15mm bore, medium grade with all fittings and fixed to walls, including cutting chases in walls etc complete all as specified and directed.\n 70 RM
73 73 Supply and fix for steel water tubing galvenised, 20 mm bore, medium grade with all fittings and fixed to walls, including cutting chases in walls etccomplete all as specified and directed.\n 30 RM
74 74 Rotational moulded polyethylene water storage tank 3 layer white colour water tank , non- toxic effect, algea formation protection (made from Virgin grade of polyetylene material which is duly stablized with anti-oxidentPlastic) of capacity 500 litres, (cylindrical vertical one piece moulded with closed top), the internal and external surfaces of tanks are smooth, clean and free from any hidden internal defects, hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,20 mm dia PTMT valves high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball and 20 mm brass stop cock etc complete all as specified and directed. 2 Each
75 75 S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, complete all as specified and directed. 2 Each
76 76 S&F 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 2 Each
77 77 S&F PVC connections 15 mm size with PTMT nuts of length 450 mm.complete all as specified and directed. 14 Each
78 78 S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for ironpipe and fixed. (Minimum weight 210 gms) complete screwed for iron pipe or brass ferrule of size 20 mm bore complete all as specified and directed.. 2 Each
79 79 S&F 32mm dia waste coupling of PTMT (half or full threaded) minimum weight 45 gms.complete all as specified and directed. 1 Each
80 80 S&F "P" or "S" trap and fixed in position with 100 mm bore pipe complete all as specified and directed 2 Each
81 81 Supply and fix 100mm dia Bends (any radius) with duck's foot or heet rest complete all as specified and directed. 1 Each
82 82 Supply and fix cast iron floor trap 75 mm, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. 3 Each
83 83 Supply and fix Salt glazed stoneware gully traps, square or round mouthed type 'P', 100 mm x 100 mm size setting and jointing in cement and sand mortar 1:1 complete all as specified and directed. 1 Each
84 84 M&L Concrete bed to drain pipes including forming cradles, in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate), for 150mm dia pipe complete all as specified and directed.. 39.5 RM
85 85 . M&L Salt glazed stone ware (SGSW) grade 'A' pipes 150mm bore laid and jointed on concrete bed complete incl testing complete all as specified and directed.. (Concrete to be measured and paid for separately). 38 RM
86 86 Construction of septic tank with cover slab RCC M-30(Design mix) for 10 users brick work in CM 1:4 (with top of slab at ground level) incl necessary excavation and earth work in any type of soil and disposal of surplus soil as directed including RCC manohole covers with angle iron welded frame complete vent shaft cowl all as shown on drg and specified. 1 Each
87 87 Soakage well in exc in ordinary soil, foundation in PCC 1:3:6 wells of honey combed and solid in M-30 Design mix concrete, including intercepting chamber, screen chamber brick work in CM, RCC cover slab in M-25/ RR masonry/ Filling with brick bats, complete of size 1.8M dia X 3.0M effective depth, all as specified and directed as per Engr-in-Charge and shown on Drg No CE/TD/1203/2003 sheet 1/2 and 2/2. 1 Each
88 88 Material and labour for Machine cut kota stone slab fooring 20-22mm thick over and including 20mm thick screed bed or bedding layer of cement mortar 1:6 for laying kota stone slab and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to obtain mirror finish complete all as specified and directed.\n 97.48 Sqm
89 89 Material and labour for Machine cut kota stone slab skirting 16-18mm thick over and including 10mm thick rendering in cement mortar 1:3 for kota stone slab skirting in vertical surfaces and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to obtain mirror finish , complete all as specified and directed. \n 12.5 Sqm
90 90 Siupply and fix for Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe -290 Gde -E-165,complete all as specified and directed.\n 364 Kg
91 91 Material & labour for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4, type B-1 smooth finished,and reforming benching as required complete all as specified and directed. 1 Each
92 92 Cutting chases, plainning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, sillls, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good cutting not exc 10 cm girth in brick walls complete all as specified and directed. 30 Sqm
93 93 Providing precast cement concrete louvers and jallies, 25mm thick (measured solid), including all mouldings With B0Type, 1:2:4 mix, (using 12.5 graded aggregate)set in cement mortar1;4 complete all as specified and directed. 48 Sqm
94 94 Damp proof course to horizontal or vertical including necessary formwork 40mm thick in cement concrete 1:2:4, type B-0. including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and directed. (Water proofing compound to be measured and paid for separately). 4.5 Sqm
95 95 Material & labour for Continuous brick edging ; with width equal to the width of the bricks of whole sub class 'B' bricks, laid dry on end With old size bricks . compound to be measured and paid for separately). 40 RM
96 96 Supply install testing and commissioning in replacement of factory made and tested (including CPRI approves test certificate) Lt feeder pillar box (KISOK) outdoor type of size 0.75x0.60x0.4 Mtr platform mounted suitable for 415 Volts 3 phase 4 wire 50 HZ AC supply system all as specified and directed, having bus bar chamber with insulated aluminium bus bar 100 Amps ratings installed on porcelain insulators. The panel shall be dust and vermin proof, make of 3.15 mm thick CRCA MS sheet and 40x40x5mm thick angle iron for base frame work. The complete feedar pillar box shall be powder coated including internal wiring PVC insulated solid copper conductor FRLS Cables appropriate size but not less than the 4 Sqmm front opening type with appons for cable entry with double door shutter including locking arrangement as per manufactures with 2 keys having includes the following :-. Incoming\n(i) MCCB 100 Amps rating 415 V, 4 Pole with breaking cap 16 KV - 01 No\n(ii) LED indicating lamp RYB-01 (Set of three) Outgoing\n (a) Analog time switch 65 Amps of make indoasian and with suitable size of 3 pole contractors -01 No Toggle switch -01 No, outgoing MCCB 63 Amps - 02 Nos, MCB TPN 40 Amps=02 Nos \n\nNote : (i) Panel shall be fixed on angle iron frame with PCC 1:2:4 type D-2 using 40mm graded stone aggregarate, 45 cm height from normal ground level.\n(ii) All incoming MCCB shall be connected through MCCB speraders with incoming Bus bars and incoming cables shall be connected with incoming bus bars.\n(iii) Cost of angle iron frame & platform, MCCB spreaders, cables glands, locking aggarments with lock and key and any addition / alteration if required will be included in this item. No extra cost will be paid to contractor.\n 2 Each
97 97 Fabrication of double and outdoor type incorporated with busbar chamber having with aluminium busbar capacity 200 amps insulated with RYB & black PVC insulation tape suitable for 415 Volts 3 Phase 4 wire system 50 C/s fixed on SMC/DMC in step way complete with dust and vermin proof provision made of CRCA MS sheet not less than 3.00 mm thick also having provision for incoming/outgoing COS/cable, 02 Nos earth terminal point complete with 10mm bolt 02 Nos nuts and 02 Nos washers 3 mm thick complete earth. The panel body must be painted with powder coated paint after the complete 7 tanks dip process to remove all impurities from the panel sheet, all the door must be fixed with detachable pin type hinges, steel door locking system, bus bar shall be through aluminium strip properly insulated fixed on SMC/DMC insulators. Panel body shall be fixed on iron angle frame of size 40x40x5mm and 40 cm grouted in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate and 40 cm above the ground level duly painted with two coat of synthetic enamel black paint over a coat of red oxide primer complete all as specified and directed. including followinf accessories:-.\n(i) MCCB 100 Amps 25 KA rating FP 415 volts-01 No (Incoming).\n(ii) MCCB TP 63 amps 25 KA 415 Volts -03 Nos (outgoing) (iii) MCB SPN 63 Amp, 10KA -02Nos ( outgoing)\n(iv) Digital Voltmeter and selector switch 0-500V-01No\n(v) RYB LED indicator lamp-03 Nos. 1 Each
98 98 Supply and fixing of 25 mm dia PVC conduit including all fitting complete all as specified and directed. 775 RM
99 99 Supply and drawing 2.5sqmm, 3 core copper cable multistranded complete all as specified and directed. 940 RM
100 100 M&L UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area 10 Sqmm 2 core complete all as specified and directed. 480 RM
101 101 M&L UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area 16 Sqmm 4 core complete all as specified and directed. 2960 RM
102 102 M&L UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area 10 Sqmm 4 core complete all as specified and directed. 1500 RM
103 103 M&L UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area 50 Sqmm 3.50 core complete all as specified and directed. 225 RM
104 104 Supply and fix in replacement aluminium conductor steel re-inforced (ACSR) Ferret/of size 6/1x3.00 mm /of size 6/1x2.59 mm (weasal) and 6/1x2.11 mm of . for LT lines on concrete poles, stretching without kinks and bends, binding with binding wire complete all as specified and directed 0.5 Per Qtl
105 105 M&L for galvanised steel wire 4mm dia fixed on pole with suitable size binding wire complete all as specified and as direced. 0.15 Qtl
106 106 Supply and Fix for shackle type, polycaronate Insulator incl one galvanised mild steel spindle, two galvanised iron washers,and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt complete all as specified and directed. 16 Each
107 107 Supply and Fix for structural steel work as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one priming coat of red oxide, one under coat , one finishing coat of aluminium paint and epoxy coating, complete all as specified and directed. 6.6 Qtl
108 108 Supply and errect steel tubular swaged pole type 410 SP-31(9,00 metres long) complete with cast iron/MS base plate, finial taper plug/welded with MS round Sheet with necessary nuts, bolts and washers duly painted with a coat of red oxide primer and two caot of aluminium paint including black and yellow strip 30 cm in height above the coping of the pole complete all as specified and directed. 88 Each
109 109 Supply and fix in repair for junction box of size 300x250x150mm made out of 1.6 mm thick CRCA sheet powder coated front hinged door with openable and self closing arrangements including aluminium bus bar 3 Phase 4 wire system of size 20mm x 5mm fixed on SMC/DMC insulators and cable entry glands for connections and MCB SP 6 Amps-01 No all as required and fixed to poles with MS clamp made out of MS flat iron of size 25x5mm and including nuts, bolts and washers complete all as specified and directed. 88 EACH
110 110 Supply and fix outdoor type street light junction box of size 350x450x200mm(minimum) made out of 2.0 mm thick CRCA sheet powder coated front openable door with locking arrangement, DIN rail mounted or any other suitable arrangement inside for fixing of MCB,s/MCCB,s and suitable size opening with gland on top and underneeth of enclosure for incoming/outgoing cable. The enclosure have suitable mounting arrangement to fix on PCC/steel pole complete all as specified and directed. 60 EACH
111 111 Supply and fix in replacement LED flood light of cap 150watt Energy saving and enviromental friendly long life verstale pressure die cast aluminium with protection IP-66 made out of pressure die cast aluminium housing suitable lens and toughened glass with high power LED as light source complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed 60 Each
112 112 Supply and fix in replacement LED flood light of cap 60watt Energy saving and enviromental friendly long life verstale pressure die cast aluminium with protection IP-66 made out of pressure die cast aluminium housing suitable lens and toughened glass with high power LED as light source with electronic chip and driver of Cat Part No:PAR0206006 of Polycab or equivalent in Crompton/Wipro/Bajaj/Philips complete all as specified and directed 88 Each
113 113 M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009 including excavation and earth work, PCC 1:2:4 pits, CI cover with angle iron frame, painting etc and testing on completion, complete all as specified and directed. Note :- All joints either strip to strip or strip to earth plate are to be fixed with welded joint. 2 Each Set
114 114 Supply and fix for DWC high densiy polyethylene pipes having dia 63/50 as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laidalong pole/along wall/in PCC on GL/roof complete all as specified and directed. 4320 RM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail